2025_Statement of Need_ Storage Tanker18000 gal.docx

DOCX document 18 KB Posted

Attached to
Double wall Storage Tankers
Solicitation number
FA460025Q0091
Issued by

About this file

The document is a Statement of Need for two double-wall horizontal storage tanks issued by the 55th Civil Engineering Squadron (55 CES) at Offutt Air Force Base. The requirement specifies two tanks with a minimum 18,000-gallon capacity each, designed for storing potassium acetate for airfield de-icing operations. Key technical specifications include carbon steel exterior, stainless steel interior, corrosion-protected interstitial space, two 3" external fluid level sight gauges, a gasoline transfer pump, 3" plumbing kit, manway access, and tandem axle mobility with a fifth-wheel plate attachment.

The solicitation (FA460025Q0091) is managed by the Department of the Air Force Air Combat Command, with technical questions due by 11:00 AM CST on 21 September 2025 and quotes due by 11:00 AM CST on 24 September 2025. Quotes must be submitted via email to ethan.taylor.22@us.af.mil and joshua.connelly.1@us.af.mil, with offer acceptance valid through 30 September 2025. The designated NAICS code is 332420 (Storage Tanks), and delivery is required by 1 November 2025 to 301 Peacekeeper Drive at Offutt AFB. Additional requirements include one on-site training session, with tank offloading and anchoring to be performed by others.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF NEED

55 CES/CEO DOUBLE WALL AIRFIELD DEICING STORAGE TANK

Requirement: Two (2) Storage Tanks Scope: The contractor shall provide two (2) Double Wall Horizontal Storage Tanks with a minimum capacity of 18,000 gallons each, along with a Transfer System. Delivery and installation at Offutt Air Force Base (AFB) are required.

Purpose: The current tanks are beyond their serviceable life. The new tanks will be used to store chemicals for anti-icing and de-icing airfield pavement surfaces.

Specifications:

· Capacity: Minimum 18,000 gallons each.

· Tank Orientation: Horizontal.

· Construction: Double Wall.

· Exterior Tank: ¼” Carbon Steel

· Interior Tank: ¼” Stainless Steel

· Interstitial Space: Coated with corrosion protection

· Exterior Coating: Corrosion protective paint.

· Sight Gauges: Two 3” External Fluid Level sight gauges.

· Warranty: Minimum 1 year.

· Additional Equipment: Gasoline Transfer Pump, 3” Plumbing Kit for Transfer System, Manway access for tank inspection.

· Mobility: Tandem Axle, Fifth-Wheel plate attachment.

· The container's storage and plumbing system shall not contain any galvanized, zinc, or brass components

· All necessary equipment to make this a finished usable working potassium acetate storage tanker with secondary confinement

· Delivery by 1 Nov 2025

· Delivery Location: 301 Peacekeeper Drive, Offutt AFB.

Additional Requirements:

1. The contractor shall provide one on-site training session.

2. Tank offloading, setting, and anchoring to the existing slab will be performed by others.

The contractor shall ensure that the provided equipment meets or exceeds the specified requirements to address the urgent need for new storage tanks to ensure effective anti-icing and de-icing operations on airfield pavement surfaces.

File details come from the government source that posted it. Updated .