This is a meeting space requirements document (Appendix I) detailing the room and setup needs for the 2025 White House Initiative on HBCU Conference over 5 days. The document outlines specific requirements for various spaces including a plenary session room that must accommodate 1,200 attendees in rounds of 10, multiple breakout rooms each accommodating 120 people, direct hiring rooms of 1,500 square feet each, a career fair space for 120 tables, and a scholars room for 130 participants.
The requirements specify detailed AV needs, particularly for the plenary session, which includes dual projection, video switching, recording capabilities, wireless microphones, and stage lighting. The document indicates various room transitions and repurposing throughout the event, with most spaces requiring 24-hour holds. Specific timing requirements are noted for various setups and breakdowns, such as career fair ending at 4pm before transitioning to exhibit hall space, and sound checks beginning at 6am for plenary sessions. The final day requires a President's Board of Advisors meeting setup with boardroom style for 25 plus gallery seating for 100 with specialized AV requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2025 HBCU RFQ.docx | DOCX document | |
| 2025 HBCU Appendix II - Price Quote Worksheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Meeting Space
| Day | Activity | Desired Set Up | Notes | Time | Proposed Space |
| Pre-Arrival Day 1 - Arrival | |||||
| Storage Room | Empty room. Possible need to add 2-3 tables, at least 450 sqft. | Must be available all day from load in to load out. | 24-Hour Hold | ||
| Staff Office | (5) Rounds of 8, plus (5) 6ft tables along the perimeter, 2 laptops, 2 wired internet lines, 10 radios with swivel earpieces | Large enough room for 45 staff in rounds + equipment. Must be available from load in to load out. Must be near or adjacent to the storage room and registration area. This will also be the staff meal room. | 24-Hour Hold | ||
| Registration Area | (6) 6ft tables plus space for registration booths, 2 wired internet lines | Needs to have ample space due to long registration lines. Heavy traffic area so open space prefered. Space needs to be able to accommodate 300 at a given time plus registration booths. Preference for an attached registration office, but if no registration office, next to storage and staff offices. | 24-Hour Hold | Set Up | |
| Career Fair | Space for up to (120) 6ft tables with 3ft in between each table and ample space in between each row. Light AV (2 large monitors, 1 wireless handheld). Small riser to fit podium and 1 monitor. | Will repurpose this space for the exhibit hall once the career fair is complete. | 24-Hour Hold | Set Up | |
| Direct Hiring Room 1 | Minimum 1500 square feet. Exact set up will vary. Space will be repurposed for breakout rooms once the career fair is complete. | Room 1 should connect or be adjacent to Room 2 | 24-Hour Hold | Set Up | |
| Direct Hiring Room 2 | Minimum 1500 square feet. Exact set up will vary. Space will be repurposed for breakout rooms once the career fair is complete. | Room 2 should connect or be adjacent to Room 1 | 24-Hour Hold | Set Up | |
| Direct Hiring Room 3 | Minimum 1500 square feet. Exact set up will vary. Space will be repurposed for breakout rooms once the career fair is complete. | Room 3 should connect or be adjacent to Room 4 | 24-Hour Hold | Set Up | |
| Direct Hiring Room 4 | Minimum 1500 square feet. Exact set up will vary. Space will be repurposed for breakout rooms once the career fair is complete. | Room 4 should connect or be adjacent to Room 3 | 24-Hour Hold | Set Up | |
| Direct Hiring Room 5 | Minimum 1500 square feet. Exact set up will vary. Space will be repurposed for breakout rooms once the career fair is complete. | Room 5 should connect or be adjacent to Room 6 | 24-Hour Hold | Set Up | |
| Direct Hiring Room 6 | Minimum 1500 square feet. Exact set up will vary. Space will be repurposed for breakout rooms once the career fair is complete. | Room 6 should connect or be adjacent to Room 5 | 24-Hour Hold | Set Up | |
| Workshop | Theater for 120. Space will be repurposed for breakout rooms once the career fair is complete. | 24-Hour Hold | Set Up | ||
| Workshop | Theater for 120. Space will be repurposed for breakout rooms once the career fair is complete. | 24-Hour Hold | Set Up | ||
| Scholars Room | Rounds of 8 for 130 scholars + moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | Room should include extra space for luggage hold on arrival and departure days. Scholars will arrive and hold here. Assigned room keys will be distributed here. | 24-Hour Hold. Programming will start at 10am. | ||
| Scholars Lunch Room | Rounds for 150 | We only need a separate room if meals cannot fit inside the Scholar Room. | 24-Hour Hold |
| Arrival Day 1 (Career Fair and Plenary Set Up) | ||||
| Storage Room | Existing | 24-Hour Hold | ||
| Staff Office | Existing | 24-Hour Hold | ||
| Registration Area | Exisiting | Registration to open at 7am. | 24-Hour Hold | |
| Plenary Session | Rounds of 10 for 1,200 (72" tables), 40'x20' stage, 12'x8' press riser, tech tables in the back. |
1 – Dual 11x20 Projection Package (rear-screen or back-of-room ground supported truss) 1 – Blue Drape Screen-to-Screen 1 – Confidence Monitor 1 – Speaker Timer 1 – Video Switcher Picture-in-Picture w/
| o | ASL (provided by ED) |
| o | StreamText CART Captions (provided by ED) |
1 – Playback Pro 1 – 50”-65” Backstage Preview Monitor w/Stand 1 – I-Mag Production Camera 1 – ISO Recording 1 – Program-out Recording 1 – HDMI Video Feed w/Embedded Audio Feed (must be mic-only, no music) 1 – Audio Mixer 8 – Wireless Mic Combo Unit (lavaliere/handheld) 8 – Boom Stands 1 – Gooseneck Podium Mic 1 – Backstage Audio Speaker/Monitor 1 – Audio Interface Device (music playlist will be provided) 1 – Speaker System Sufficient Plenary Space 1 – Wireless Cue 1 – Stage Lighting Package 1 – LED Uplighting Package 3 – wireless clear comms for ED to communicate with producer/stage manager X – Vendor to identify quantity of PCs/Macs required as part of their technical approach.
X – Vendor to identify required labor as part of their technical approach - must have an experienced stage manager/producer
| 24-Hour Hold | Set Up | ||||
| VIP Green Room | Round or conference table for 8 + soft seating for small lounge area (if available from hotel) | Close to restroom, close to plenary session. | 24-Hour Hold | ||
| Career Fair | Exisiting | 24-Hour Hold. To end at 4pm, then flip for exhibit hall. | |||
| Direct Hiring Room 1 | Exisiting | 24-Hour Hold. To end at 4pm, then flip for breakouts. | |||
| Direct Hiring Room 2 | Exisiting | 24-Hour Hold. To end at 4pm, then flip for breakouts. | |||
| Direct Hiring Room 3 | Exisiting | 24-Hour Hold. To end at 4pm, then flip for breakouts. | |||
| Direct Hiring Room 4 | Exisiting | 24-Hour Hold. To end at 4pm, then flip for breakouts. | |||
| Direct Hiring Room 5 | Exisiting | 24-Hour Hold. To end at 4pm, then flip for breakouts. | |||
| Direct Hiring Room 6 | Exisiting | 24-Hour Hold. To end at 4pm, then flip for breakouts. | |||
| Workshop | Exisiting | 24-Hour Hold. To end at 4pm, then flip for breakouts. | |||
| Workshop | Exisiting | 24-Hour Hold. To end at 4pm, then flip for breakouts. | |||
| Breakout Room 1 | Rounds for minimum of 120 + head table with 5 chairs, moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Breakout Room 2 | Theater for minimum of 120 + head table with 5 chairs, moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Breakout Room 3 | Theater for minimum of 120 + head table with 5 chairs, moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Breakout Room 4 | Theater for minimum of 120 + head table with 5 chairs, moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Breakout Room 5 | Theater for minimum of 120 + head table with 5 chairs, moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Breakout Room 6 | Theater for minimum of 120 + head table with 5 chairs, moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Breakout Room 7 | Theater for minimum of 120 + head table with 5 chairs, moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Ad Hoc Room 1 | Classroom for 25-50. No AV. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Ad Hoc Room 2 | Rounds for 25-50. No AV. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Communications Office | Rounds for 20. Space will need a lot of floor space for equipment. | 24-Hour Hold. To set up at 4pm. | Set Up | ||
| Scholars Room | Existing | 24-Hour Hold | |||
| Presidents & Chancellors | Rounds of 8 for 100 + moderate AV (screen, projector, laptop, presentation remote, 3 table mics), podium with podium mic. | Must be a spacious room. | 24-Hour Hold | Set Up | |
| Reception | Reception style for 500 + food stations, bar, dance floor, stage + portion of existing AV. Possibilty to repurpose plenary space. | 4pm-11:59pm | |||
| Day 2 (Conference Day 1) | |||||
| Storage Room | Existing | 24-Hour Hold | |||
| Staff Office | Existing | 24-Hour Hold | |||
| Registration Area | Existing | 24-Hour Hold | |||
| VIP Green Room | Existing | 24-Hour Hold | |||
| Plenary Session | Exisiting | Sounds checks to begin at 6am. Plated luncheon to be served 12:30pm-2pm. | 24-Hour Hold | ||
| Exhibit Hall | Exisiting | 24-Hour Hold | |||
| Scholars Room | Existing | 24-Hour Hold | |||
| Presidents & Chancellors | Existing | 24-Hour Hold | |||
| Breakout Room 1 | Exisiting | 24-Hour Hold | |||
| Breakout Room 2 | Exisiting | 24-Hour Hold | |||
| Breakout Room 3 | Exisiting | 24-Hour Hold | |||
| Breakout Room 4 | Exisiting | 24-Hour Hold | |||
| Breakout Room 5 | Exisiting | 24-Hour Hold | |||
| Breakout Room 6 | Exisiting | 24-Hour Hold | |||
| Breakout Room 7 | Exisiting | 24-Hour Hold | |||
| Ad Hoc Room 1 | Exisiting | 24-Hour Hold | |||
| Ad Hoc Room 2 | Exisiting | 24-Hour Hold | |||
| Communications Office | Exisiting | 24-Hour Hold | |||
| EICA Awards Dinner | Existing | Repurpose plenary space. | Sound checks to begin at 4pm. Doors open at 5:30pm, programming from 6pm-9pm for flip back to plenary session. | ||
| Day 3 (Conference Day 2) | |||||
| Storage Room | Existing | 24-Hour Hold | |||
| Staff Office | Existing | 24-Hour Hold | |||
| Registration Area | Existing | 24-Hour Hold | |||
| Plenary Session | Existing | Sound checks to begin at 6am. Plated luncheon to be served 12:30pm-2pm. | 24-Hour Hold | ||
| VIP Green Room | Existing | 24-Hour Hold | |||
| Exhibit Hall | Existing | 24-Hour Hold | |||
| Scholars Room | Existing | 24-Hour Hold | |||
| Presidents & Chancellors | Existing | 24-Hour Hold | |||
| Breakout Room 1 | Existing | 24-Hour Hold | |||
| Breakout Room 2 | Existing | 24-Hour Hold | |||
| Breakout Room 3 | Existing | 24-Hour Hold | |||
| Breakout Room 4 | Existing | 24-Hour Hold | |||
| Breakout Room 5 | Existing | 24-Hour Hold | |||
| Breakout Room 6 | Existing | 24-Hour Hold | |||
| Breakout Room 7 | Existing | 24-Hour Hold | |||
| Ad Hoc Room 1 | Existing | 24-Hour Hold | |||
| Ad Hoc Room 2 | Existing | 24-Hour Hold | |||
| Communications Office | Existing | 24-Hour Hold | |||
| Federal Meet & Greet | (40) High boys + small stage, check-in table outside room, podium, AV | Can repurpose plenary space with rounds removed for new set. Set up to begin immediately after the luncheon around 2pm, vendors to arrive by 3:30pm, doors open at 5pm. | 2pm-8pm | ||
| Day 4 (Conference Day 3) | |||||
| Storage Room | Existing | 24-Hour Hold | |||
| Staff Office | Existing | 24-Hour Hold | |||
| Registration Area | Existing | 24-Hour Hold | |||
| Plenary Session | Existing | Sound checks to begin at 6am. Plated luncheon to be served 12:30pm-2pm. | 24-Hour Hold | ||
| VIP Green Room | Existing | 24-Hour Hold | |||
| Exhibit Hall | Existing | 24-Hour Hold | |||
| Scholars Room | Existing | 24-Hour Hold | |||
| Presidents & Chancellors | Existing | 24-Hour Hold | |||
| Breakout Room 1 | Existing | 24-Hour Hold | |||
| Breakout Room 2 | Existing | 24-Hour Hold | |||
| Breakout Room 3 | Existing | 24-Hour Hold | |||
| Breakout Room 4 | Existing | 24-Hour Hold | |||
| Breakout Room 5 | Existing | 24-Hour Hold | |||
| Breakout Room 6 | Existing | 24-Hour Hold | |||
| Breakout Room 7 | Existing | 24-Hour Hold | |||
| Ad Hoc Room 1 | Existing | 24-Hour Hold | |||
| Ad Hoc Room 2 | Existing | 24-Hour Hold | |||
| Communications Office | Existing | 24-Hour Hold | |||
| Day 5 (Conference Day 4 - PBA) | |||||
| Storage Room | Existing | 24-Hour Hold | |||
| Staff Office | Existing | 24-Hour Hold | |||
| President's Board of Advisors (PBA) | Boardroom for 25 + gallery seating for 100, table for transcriber, table for staff, registraton table (outside the room), heavy AV (screen, projector, presentation remote, individual push to talk mics for board) | 24-Hour Hold | |||
| PBA Meal Room | Rounds and cocktail seating for 30 | Must be separate but nearby meeting. | 24-Hour Hold |