2025-103plans.pdf

PDF 32 MB Posted

Attached to
F. M. 741 Water Meter Vault
Solicitation number
2025-103
Issued by
Dallas County, Texas

About this file

This document is a comprehensive set of engineering design plans and drawings for the Mesquite McKenzie-Lawson Road Interceptor Improvements project by the City of Mesquite, Texas, prepared by Garver, LLC. The project involves constructing approximately 10,300 linear feet of 15-inch to 24-inch wastewater pipeline, connecting to an existing 27-inch sanitary sewer south of Lawson Road and decommissioning the existing McKenzie Lift Station. The project extends from McKenzie Road to Lawson Road and encompasses 14.5 total acres, with 5.6 acres to be directly disturbed during construction. The design is dated October 2024 and represents a 100% preliminary design not yet ready for construction or bidding.

The project includes multiple technical components such as installing polymer concrete manholes at various stations, utilizing SDR-26 PVC and ductile iron pipes, implementing steel casing at multiple road and utility crossings, and incorporating flowable fill and erosion control measures. The design accounts for existing utilities, property easements, and environmental considerations, including temporary construction easements and permanent utility easements across multiple property owners. The electrical design includes a new meter vault, flow transmitter, and electrical service disconnect, with specific requirements for grounding, conduit installation, and utility coordination. The total project appears to be funded by the City of Mesquite and will require detailed coordination with local utility companies and property owners along the proposed interceptor route.

View the file

Other files

File Type Posted
2025-103adn1.pdf PDF
2025-103specs.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NO SCALE

VICINITY MAP

GARVER PROJECT NO. 23W05125

OCTOBER 2024

INTERCEPTOR IMPROVEMENTS

CITY OF MESQUITE

MESQUITE MCKENZIE-LAWSON RD

MESQUITE, TEXAS

3000 Internet Boulevard Suite 400

Frisco, TX 75034

(972) 377-7480

PROJECT SITE

BASIS

100% DESIGN SUBMITTAL

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-G

1.

dw g L as t S av e:

0/

/2

4:

P M

L as t s av ed b y:

E

M at a La st p lo tte d by

: M at a, E ric a

Pl ot

S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:2 .5

Pl ot

D at e:

0/

/2

5:

P

M P lo tte r u se d:

N on e

01-G001

COVER SHEET

CITY COUNCIL

DANIEL ALEMAN, JR. MAYOR

JEFF CASPER DISTRICT 1

KENNY GREEN DISTRICT 2

ELIZABETH RODRIGUEZ-ROSS DISTRICT 3

TANDY BOROUGHS DISTRICT 4

B.W. SMITH DISTRICT 5

BRANDON MURDEN DISTRICT 6

CLIFF KEHELEY CITY MANAGER

RAYMOND RIVAS ASSISTANT CITY MANAGER

CHRIS SANCHEZ ASSISTANT CITY MANAGER

SUZY CLUSE ASSISTANT CITY MANAGER

CURT CASSIDY DIRECTOR OF PUBLIC WORKS

SHEET LIST TABLE

DWG. NO. SHT. NO. DESCRIPTION

GENERAL

01-G001 01 COVER SHEET

01-G002 02 GENERAL NOTES 1

01-G003 03 GENERAL NOTES 2

01-G004 04 ABBREVIATIONS

01-G005 05 LEGEND

01-G006 06 ELECTRICAL SYMBOL LEGENDS

01-G007 07 ELECTRICAL NOTES AND ABBREVIATIONS

01-G008 08 PROJECT CONTROL & BORE LOCATIONS

01-G009 09 GEOTECHNICAL BORING LOGS 1

01-G010 10 GEOTECHNICAL BORING LOGS 2

SITE CIVIL

05-C101 11 OVERALL LAYOUT AND KEY MAP

05-C102 12 EASEMENT LAYOUT 1

05-C103 13 EASEMENT LAYOUT 2

05-C301 14 PLAN AND PROFILE STA 10+00 TO STA 14+00

05-C302 15 PLAN AND PROFILE STA 14+00 TO STA 19+00

05-C303 16 PLAN AND PROFILE STA 19+00 TO STA 24+00

05-C304 17 PLAN AND PROFILE STA 24+00 TO STA 29+00

05-C305 18 PLAN AND PROFILE STA 29+00 TO STA 34+00

05-C306 19 PLAN AND PROFILE STA 34+00 TO STA 39+00

05-C307 20 PLAN AND PROFILE STA 39+00 TO STA 44+00

05-C308 21 PLAN AND PROFILE STA 44+00 TO STA 47+00

05-C309 22 PLAN AND PROFILE STA 49+00 TO STA 54+00

05-C310 23 PLAN AND PROFILE STA 54+00 TO STA 59+00

05-C311 24 PLAN AND PROFILE STA 59+00 TO STA 64+00

05-C312 25 PLAN AND PROFILE STA 64+00 TO STA 69+00

05-C313 26 PLAN AND PROFILE STA 69+00 TO STA 74+00

05-C314 27 PLAN AND PROFILE STA 74+00 TO STA 79+00

05-C315 28 PLAN AND PROFILE STA 79+00 TO STA 84+00

05-C316 29 PLAN AND PROFILE STA 84+00 TO STA 89+00

05-C317 30 PLAN AND PROFILE STA 89+00 TO STA 94+00

05-C318 31 PLAN AND PROFILE STA 94+00 TO STA 99+00

05-C319 32 PLAN AND PROFILE STA 99+00 TO STA 104+00

05-C320 33 PLAN AND PROFILE STA 104+00 TO STA 108+50

99-C501 34 STANDARD DETAILS 1

99-C502 35 STANDARD DETAILS 2

99-C503 36 STANDARD DETAILS 3

99-C504 37 STANDARD DETAILS 4

99-C505 38 SWPPP NARRATIVE

99-C506 39 EROSION CONTROL DETAILS

10-X101 40 LIFT STATION DEMOLITION

ELECTRICAL

90-E101 41 ELECTRICAL SITE PLAN AND DETAIL

90-E102 42 ELECTRICAL DETAILS 2

L

I

C

E

N S

E

D

S

T

A

T

E

O

F

X

A

S

P

R

O

F

E

S

S

I

O

N A

N

G

I

N

E

E

R

KORY WILKINSON

135779

Digitally Signed 10/28/2024 sa14457 Release for construction

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-G

4.

dw g L as t S av e:

2/

/2

:5

AM

L as t s av ed b y:

E

M at a La st p lo tte d by

: M at a, E ric a

Pl ot

S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:1 P lo t D at e:

0/

/2

5:

P M

P lo tte r u se d:

D

W G

T o

PD

F.

pc

01-G002

GENERAL NOTES 1

C

E

N S

E

D

S

T

A

X

A

S

P

R

O

F

E

S

S

I

O

N

G

I

N

E

E

R

KORY WILKINSON

135779

Digitally Signed 10/28/2024

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-G

4.

dw g L as t S av e:

2/

/2

:5

AM

L as t s av ed b y:

E

M at a La st p lo tte d by

: M at a, E ric a

Pl ot

S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:1 P lo t D at e:

0/

/2

5:

P M

P lo tte r u se d:

D

W G

T o

PD

F.

pc

01-G003

GENERAL NOTES 2

C

E

N S

E

D

S

T

A

X

A

S

P

R

O

F

E

S

S

I

O

N

G

I

N

E

E

R

KORY WILKINSON

135779

Digitally Signed 10/28/2024

ABBREV DESCRIPTION SHT

TYPE

ABBREV DESCRIPTION SHT

TYPE

ABBREV DESCRIPTION SHT

TYPE

ABBREV DESCRIPTION SHT

TYPE

ABBREV DESCRIPTION SHT

TYPE

ABBREV DESCRIPTION SHT

TYPE

ABBREV DESCRIPTION SHT

TYPE

A AMP E

ABC ABOVE COUNTER E

ABV ABOVE M

A/C AIR CONDITIONER, AIR

CONDITIONING

M

ACC AIR COOLED CHILLER M

ACCU AIR COOLED CONDENSING

UNIT

M

ACS ACCESS CONTROL

SYSTEM

E

ACU AIR CONDITIONING UNIT E

AFF ABOVE FINISHED FLOOR E,M,S,

C

AFG ABOVE FINISHED GRADE E

AIC AMPS INTERRUPTING

CAPACITY

E

AL ALUMINUM S

ALUM ALUMINUM SULFATE C

AM AMP-METER E

AMP AMPERES M

ANN ANNUNCIATOR E

ANSI AMERICAN NATIONAL

STANDARDS INSTITUTE

M

AP AERIAL PRIMARY E

APD AIR PRESSURE DROP M

APPROX APPROXIMATE C

ARCH ARCHITECT,

ARCHITECTURAL

S

ARI AIR CONDITIONING &

REFRIGERATION

INSTITUTE

M

AS AERIAL SECONDARY E

ASHRAE AMERICAN SOCIETY OF

HEATING, REFRIGERATION

& AIR CONDITIONING

ENGINEERS

M

ASME AMERICAN SOCIETY OF

MECHANICAL ENGINEERS

M

ASPH ASPHALT C

ASSY ASSEMBLY C

ASTM AMERICAN SOCIETY OF

TESTING AND MATERIALS

M

ATS AUTOMATIC TRANSFER

SWITCH

E

AUX AUXILIARY E,M

AWWA AMERICAN WATER WORKS

ASSOCIATION

M

BD BACKDRAFT DAMPER M

BFI BLOWN FUSE INDICATOR E

BFW BOILER FEED WATER M

BG BACK GOUGE S

BI BYPASS ISOLATION E

BKR BREAKER E,M

BLDG BUILDING C

BLK BLOCK C

BM BENCHMARK C

BOD BOTTOM OF DUCT M

BOP BOTTOM OF PIPE M

BOS BOTTOM OF STRUCTURE M

BOT BOTTOM C

BTU BRITISH THERMAL UNIT M

C CONDUIT E

CB CIRCUIT BREAKER E

CCJ CRACK CONTROL JOINT S

CCTV CLOSED CIRCUIT

TELEVISION

E

CFH CUBIC FEET PER HOUR M

CFM CUBIC FEET PER MINUTE M

CFS CUBIC FEET PER SECOND M

CGRS PVC COATED GALVANIZED

RIGID STEEL

E

CI CAST IRON C

CIP CAST IRON PIPE C

CIRC CIRCULATING M

CJ CONSTRUCTION JOINT S,C

CJP COMPLETE JOINT

PENETRATION

S

CKT CIRCUIT E,M

CL CENTERLINE E,M,S

CL CLASS C

CLG CEILING M

CMU CONCRETE MASONRY UNIT M,S,C

COL COLUMN M

COM COMMON E

CONC CONCRETE C

CONN CONNECTION C

CONT CONTINUOUS E,S,C

CP CONTROL PANEL E

CP CONTROL POINT C

CPT CONTROL POWER

TRANSFORMER

E

CPVC CHLORINATED POLYVINYL

CHLORIDE

M

CR CONTROL RELAY E

CRI COLOR RENDERING INDEX E

CS CORD SET E

CU COEFFICIENT OF

UTILIZATION

E

CU COPPER M

CW COLD WATER M

°C DEGREES CELSIUS M

DB DRY BULB M

dB DECIBEL M

DDC DIRECT DIGITAL

CONTROL(S)

M

DEB DIRECT EARTH BURIED E

DI DUCTILE IRON C

DIA DIAMETER S,C

DIP DUCTILE IRON PIPE C

DISC DISCONNECT M

DR DIMENSION RATIO C

DX DIRECT EXPANSION M

EA EXHAUST AIR, EXPANSION

ANCHOR, EACH

C,S,M

EAT ENTERING AIR

TEMPERATURE

M

EC EMPTY, EMBEDDED

CONDUIT

E

ECC ECCENTRIC M

EDB ENTERING DRY BULB M

EF EXHAUST FAN E

EF EACH FACE S

EFF EFFLUENT C

EG EQUIPMENT GROUND E

EJ EXPANSION JOINT S

EL, ELEV ELEVATION E,S,M,

C

ELEC ELECTRICAL M,S,C

EMT ELECTRICAL METALLIC

TUBING

E

ENCL ENCLOSURE M

EQ EQUAL C

EQUIP EQUIPMENT M

ES EVENLY SPACED, EACH

SIDE

S

ESP EXTERNAL STATIC

PRESSURE

M

ETM ELAPSED TIME METER E

EW EACH WAY S

EWB ENTERING WET BULB M

EWC ELECTRICAL WATER

COOLER

M

EWT ENTERING WATER

TEMPERATURE

M

EX EXISTING C

EXH EXHAUST M

EXP EXPANSION C

EXST EXISTING S

EXT EXTERIOR S

FA FIRE ALARM E,M

FACP FIRE ALARM CONTROL

PANEL

E

FC FAN COIL E

FCJ FLOOR CONSTRUCTION

JOINT

C

FD FLOOR DRAIN S

FDS FUSED DISCONNECT

SWITCH

E

FFE FINISHED FLOOR

ELEVATION

S,C

FH FIRE HYDRANT C

FIN GR FINISH GRADE C

FL FLOW LINE M,C

FLA FULL LOAD AMPERES M

FLEX FLEXIBLE M

FLG FLANGED C

FLR FLOOR E,S

FND FOUNDATION S

FOB FLAT ON BOTTOM M

FOC FIBER OPTIC CABLE E

FPM FEET PER MINUTE M

FS FLOAT SWITCH E

FS FOOTING STEP, FAR SIDE S

FT FEET, FOOT E,S,C

FTG FOOTING C

FVNR FULL VOLTAGE

NON-REVERSING STARTER

E

FVR FULL VOLTAGE REVERSING

STARTER

E

°F DEGREES FAHRENHEIT M

GA GAUGE, GAGE M,S

GAL GALLON M

GALV GALVANIZED M,S

GDT GRAPHIC DISPLAY

TERMINAL

E

GFI,

GFCI

GROUND FAULT CIRCUIT

INTERRUPTER

E,M

GL GAS LINE C

GND GROUND E

GPD GALLONS PER DAY M

GPH GALLONS PER HOUR M

GPM GALLONS PER MINUTE M

GR GRADE C

GRND GROUND M

GRS GALVANIZED RIGID STEEL E

GV GATE VALVE C

H,HT HEIGHT M

HD HEAD, HUB DRAIN M

HID HIGH INTENSITY

DISCHARGE

E

HOA HAND-OFF-AUTOMATIC E,M

HORIZ HORIZONTAL M,C,S

HP HORSEPOWER, HEAT

PUMP

E,M

HR HOUR E

HSTAT HUMIDISTAT M

HTG HEATING M

HTR HEATER M

HW HOT WATER M

HWY HIGHWAY C

HYD HYDRANT M

Hz HERTZ M

ID INSIDE DIAMETER M,CIIV

L

IDS INTRUSION DETECTION

SYSTEM

E

IE INVERT ELEVATION M

IG ISOLATED GROUND E

IJ ISOLATION JOINT S

IN INCHES C

IN WC INCHES OF WATER

COLUMN

M

INF INFLUENT C

INT INTERIOR S

INV INVERT C

ISP INDIVIDUALLY SHIELDED

PAIR

E

JB JUNCTION BOX E

JT JOINT C

KIP 1,000 POUNDS S

KLF KIPS PER LINEAR FOOT S

KSF KIPS PER SQUARE FOOT S

kVA KILOVOLT-AMPERES E,M kVAR KILOVOLT-AMPERE, REACTIVE

E kW KILOWATTS E,M kWh KILOWATT-HOUR M

L LENGTH M

LA LIGHTNING ARRESTER E

LAT LEAVING AIR

TEMPERATURE

M

LBS, # POUNDS S,M

LDB LEAVING DRY BULB M

LEN LENGTH C

LG LONG C

LIN LINEAL, LINEAR C

LLF LIGHT LOSS FACTOR E

LLH LONG LEG HORIZONTAL S

LLV LONG LEG VERTICAL S

LO LUGS ONLY E

LOC LOCATION C

LOR LOCAL-OFF-REMOTE E

LP LOW PRESSURE M

LRA LOCKED ROTOR AMPERES M

LSL LONG SLOT S

LT LEFT C

LTG LIGHTING M

LV LOW VOLTAGE E

LWB LEAVING WET BULB M

LWT LEAVING WATER

TEMPERATURE

M

MANUF MANUFACTURER C

MAX MAXIMUM C,S

MBTU,

MBH

1000 BTU PER HOUR M

MCA MINIMUM CIRCUIT

AMPACITY

M

MCB MAIN CIRCUIT BREAKER E

MCB MINIMUM CIRCUIT

BREAKER

M

MCC MOTOR CONTROL CENTER E

MCP MOTOR CIRCUIT

PROTECTOR

E

MD MOTORIZED DAMPER M

MECH MECHANICAL S

MFR MANUFACTURER S,M,E

MGD MILLION GALLONS PER

DAY

C

MH MANHOLE, METAL HALIDE M,C

MIN MINIMUM C,S,E

MISC MISCELLANEOUS C

MJ MECHANICAL JOINT C

MLO MAIN LUGS ONLY E

MOCP MAXIMUM OVER CURRENT

PROTECTION

M

MS MOTOR STARTER E

MTD MOUNTED E

N NORTH C

N.O. NORMALLY OPEN M

N/A NOT APPLICABLE M

NC NOISE CRITERIA,

NORMALLY CLOSED

M

NCTO NORMALLY CLOSED TIMED

OPEN

E

NEC NATIONAL ELECTRICAL

CODE

M

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S

ASSOCIATION

M

NEUT NEUTRAL E

NFDS NON-FUSED DISCONNECT

SWITCH

E

NFPA NATIONAL FIRE

PROTECTION

ASSOCIATION

M

NIC NOT IN CONTRACT C,M

NL NIGHT LIGHT E

NO,# NUMBER C

NOTC NORMALLY OPEN TIMED

CLOSED

E

NS NEAR SIDE S

NTS NOT TO SCALE C,M,E

NWSL NORMAL WATER SURFACE

LEVEL

C

OA OUTSIDE AIR M

OBD OPPOSED BLADE DAMPER M

OC ON CENTER C,S,E

OD OUTSIDE DIAMETER M,C

OFCI OWNER FURNISHED/ M

OH OVERHEAD M,E

OH OPPOSITE HAND S

OHP OVERHEAD PRIMARY E

OHS OVERHEAD SECONDARY E

OL OVERLOAD E

OS&Y OUTSIDE STEM AND YOKE M

OSHA OCCUPATIONAL SAFETY &

HEALTH ADMINISTRATION

M

OVS OVERSIZED S

PB PUSH BUTTON E

PCF POUNDS PER CUBIC FOOT S

PD PRESSURE DROP M

PE PLAIN END C

PEC PHOTO ELECTRIC CELL E

PERM PERMENANT C

PF POWER FACTOR E

PFCC POWER FACTOR

CORRECTION CAPACITOR

E

PH, Ø PHASE M

PI POINT OF INTERSECTION C

PIV POST INDICATOR VALVE M

PJP PARTIAL JOINT

PENETRATION

S

PL PILOT LIGHT E

PL, PLS PLATE, PLACES C

PLF POUNDS PER LINEAR FOOT S

PMR PHASE MONITOR RELAY E

PNL PANEL M,E

PO PUSH ON C

PP POWER POLE C

PRV PRESSURE RELIEF VALVE S,M

PROP PROPOSED C

PSF POUNDS PER SQUARE

FOOT

S,M

PSI POUNDS PER SQUARE

INCH

C,S,M

PSIA POUNDS PER SQUARE

INCH ABSOLUTE

M

PSIG POUNDS PER SQUARE

INCH GAUGE

M

PT POINT C

PTT PUSH-TO-TEST E

PVC POLYVINYL CHLORIDE C,M,E

R, RAD RADIUS C

RA RETURN AIR M

RCP REFLECTED CEILING PLAN M

RCP REINFORCED CONC PIPE C

RD ROOF DRAIN M

RE: REFERENCE, REFER M

RECIRC RECIRCULATE M

RECPT RECEPTACLE E

RED REDUCER C

REINF REINFORCMENT C,S,M

REQD REQUIRED C,S,M

RH RELATIVE HUMIDITY M

RHG REFRIGERANT HOT GAS M

RJ RESTRAINED JOINT C

RL REFRIGERANT LIQUID M

RLA RUNNING LOAD AMPERES M

RM ROOM M,E

ROW,

R/W

RIGHT-OF-WAY C

RPM REVOLUTIONS PER MINUTE M

RS REFRIGERANT SUCTION M

RS RESILIENT SEAT C

RT RIGHT C

RVAT REDUCED VOLTAGE

AUTO-TRANSFORMER

STARTER

E

S SECOND E

S SOUTH, SLUDGE C

SA SURGE ARRESTER E

SA SUPPLY AIR M

SCH SCHEDULE C

SD SMOKE DAMPER, STORM

DRAIN

M

SDBC SOFT DRAWN BARE

COPPER

E

SE SERVICE ENTRANCE E

SEC SECTION M

SECT SECTION C

SF SQUARE FEET C,M

SHT SHEET C,E

SIM SIMILAR S

SN SOLID NEUTRAL E

SP STATIC PRESSURE M

SPEC SPECIFICATIONS C,S

SQ SQUARE C,M

SS STAINLESS STEEL C,S,E

SS STAINLESS STEEL,

SANITARY SEWER

M

SSL SHORT SLOT S

SSOL SOLID STATE OVERLOAD

RELAY

E

ST SOUND TRAP, STEAM TRAP M

STA STATION C,E

STD STANDARD C,S,M

STL STEEL S

STP SHIELDED TWISTED PAIR E

SURF SURFACE M

SUSP SUSPEND, SUSPENDED M

SW SWITCH E

T&B TOP AND BOTTOM C,S

TBM TEMPORARY BENCHMARK C

TC TIME CLOCK E

TCE TEMPORARY

CONSTRUCTION

EASEMENT

C

TD TIME DELAY E

TDD TIME DELAY ON

DE-ENERGIZATION

E

TDE TIME DELAY ON

ENERGIZATION

E

TEL TELEPHONE E

TEMP TEMPORARY, TEMPERED C

THD TOTAL HARMONIC

DISTORTION

E

THK THICKNESS C

THRU THROUGH M

TOB TOP OF BEAM S

TOC TOP OF CONCRETE S

TOC TOP OF CURB C

TOD TOP OF DUCT M

TOF TOP OF FOOTING S

TOS TOP OF STEEL S

TP TOTAL PRESSURE M

TSP TOTAL STATIC PRESSURE M

TSTAT THERMOSTAT M

TYP TYPICAL C,S,E

U/F UNDER FLOOR M

U/G UNDERGROUND M

U/S UNDER SLAB M

UG UNDER GROUND E

UGE UNDER GROUND ELECTRIC E

UGP UNDERGROUND PRIMARY E

UGS UNDERGROUND

SECONDARY

E

UH UNIT HEATER E

UL UNDERWRITERS

LABORATORIES, INC.

M

UNO UNLESS NOTED

OTHERWISE

E

UNO UNLESS NOTED

OTHERWISE

S

UTP UNSHIELDED TWISTED

PAIR

E

V VOLT, VALVE C,M,E

VA VOLT-AMPERE M,E

VAC VACUUM M

VAV VARIABLE AIR VOLUME M

VCJ VERTICAL CONSTRUCTION

JOINT

S

VD VOLUME DAMPER M

VERT VERTICAL C,S,M

VFD VARIABLE FREQUENCY

DRIVE

E

VM VOLT-METER E

VT VENTILATOR C

VTR VENT THROUGH ROOF M

W WATT, WIRE, WIDTH,

WINDOW, WATER

C,S,M, E

W/ WITH C,S,M,

E

W/O WITHOUT C,M

WB WET BULB M

WC WATER COLUMN M

WH WEATHER HEAD E

WL WATER LINE C

WM WATT METER E

WP WEATHERPROOF E

WPD WATER PRESSURE DROP M

WS WATERSTOP C,S

WT WATERTIGHT, WEIGHT M

WTM WATER TRANSMISSION

MAIN

C

WWF WELDED WIRE FABRIC C

X BY C

XMFR TRANSFORMER M,E

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-G

2.

dw g L as t S av e:

2/

/2

:5

AM

L as t s av ed b y:

E

M at a La st p lo tte d by

: M at a, E ric a

Pl ot

S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:2 .5

Pl ot

D at e:

0/

/2

5:

P

M P lo tte r u se d:

N on e

01-G004

ABBREVIATIONS

C

E

N S

E

D

S

T

A

X

A

S

P

R

O

F

E

S

S

I

O

N

G

I

N

E

E

R

KORY WILKINSON

135779

Digitally Signed 10/28/2024

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

PROFILE

RIP RAP

GRAVEL ROAD OR DRIVE

EXISTING CONCRETE

PROPOSED CONCRETE

CIVIL LEGEND NOTES

1. GRAY SCALED LINE TYPES AND SYMBOLS INDICATE EXISTING ITEMS. BOLD

SCALED LINE TYPES AND SYMBOLS INDICATE PROPOSED ITEMS.

2. ADDITIONAL PROCESS LINES MAY BE DENOTED BY A LINE TYPE WITH THE FLOW

STREAM IDENTIFIER.

3. LINES OF 12 INCH DIAMETER OR GREATER ARE SHOWN AT NOMINAL DIAMETER.

LINES LESS THAN 12 INCH DIAMETER ARE SHOWN AS A SINGLE LINE.

OHE

CIVIL LEGEND

CABLE TV

SANITARY SEWER

WATER LINE

NATURAL GAS

OVERHEAD ELECTRIC

STORM DRAIN

SILT FENCE

POTABLE WATER

NON-POTABLE WATER

PROCESS DRAIN

UNDERGROUND ELECTRIC

UNDERGROUND TELEPHONE

PROPERTY LINE

FENCE

WATER EDGE

TREE LINE

SHRUB/BUSH

YARD HYDRANT/SPIGOT

VALVE

WATER METER

CATV

SS

W

C

SD

SF

W1

W2

PD

UGE

UGT

PL

COMMUNICATION

RIGHT-OF-WAYR/W

FLOWLINE

FIRE LINEF

EASEMENT LINE

TOP OF BANKTOB

TOS TOE OF SLOPE

INDICATES ABANDONED LINE(A)

12" INDICATES SIZE OF LINE12"

X

TREE

UTILITY POLE

WM

TELEPHONE JUNCTION BOXTELE

TELEPHONE PEDESTAL

TELEPHONE MANHOLETELE

MH

TELEVISION PEDESTALCABLE

SYMBOL DESCRIPTION

EXISTING PIPE TO BE ABANDONED

EXISTING PIPE TO BE DEMOLISHED

FLOODWAYI I

FIRE HYDRANT

ELECTRIC MANHOLE

SANITARY SEWER MANHOLE

FLARED END SECTION (FES)

CATCH BASIN/JUNCTION BOX

SIGN

BENCH MARK/GEOTECHNICAL BORE

SURVEY CONTROL POINT

GUY WIRE ANCHOR

CONCRETE HEADWALL

SLOPE DIRECTION INDICATOR

PROPERTY PIN

LIGHT POLE

SS

EMH

PROCESS DRAIN MANHOLEPD

CLEANOUTCO

ELECTRIC BOXEB

ELECTRIC DUCT MARKEREDM

ELECTRIC METEREM

FIBER OPTIC BOXFOC

FIBER OPTIC MANHOLEFOMH

FIBER OPTIC CABLE RISER/PEDESTALFOC

GAS METERGM

BOLLARD

GAS REGULATOR

IRRIGATION CONTROL VALVEICV

MANHOLEMH

STORM DRAIN MANHOLESD

SYMBOL DESCRIPTION

MW MONITORING WELL

SPRINKLER HEAD

EXISTING ASPHALT

DEMOLISH

SSL

WSL WATER SERVICE LINE

SEWER SERVICE LINE

(IN FEET)

0 20' 40' 60'10'

SYMBOL INDICATES

NORTH DIRECTION

SYMBOL INDICATES A

GRAPHICAL BAR SCALE

3923-003 D33

BLOW-OFF VALVE

BUTTERFLY VALVEAIR RELEASE VALVE

PLUG VALVE

B

T DIVISION NUMBER

DETAIL NUMBER

LABEL DESCRIPTION

CALLOUT DENOTES A STANDARD

DETAIL REFERENCE

SYMBOL DESCRIPTION

GENERAL CONVENTIONS

SCALE: NONE

05-C501

TITLE

05-C501

CALLOUT DENOTES A CIVIL DETAIL

REFERENCE (THIS EXAMPLE IS

DETAIL 1 ON DRAWING NUMBER

05-C501)

APPURTENANCE SYMBOLS

DESCRIPTION

GATE VALVE

TITLE DENOTES A CIVIL DETAIL

(THIS EXAMPLE IS DETAIL 1 ON

DRAWING NUMBER 05-C501)

CALLOUT DENOTES A KEYED NOTE

REFERENCE

CLOUDED REGION INDICATES A

REVISED AREA

GENERAL IDENTIFICATION

B

T DETAIL NUMBER

DRAWING NUMBER

CAUTION! EXIST. XXX CAUTION CALLOUT

B

T CHEMICAL LINE PROFILE NUMBER 1

DRAWING NUMBER

B

T ELECTRICAL DUCT BANK PROFILE NUMBER 1

DRAWING NUMBER

B

T GAS LINE PROFILE NUMBER 1

DRAWING NUMBER

B

T PROCESS LINE PROFILE NUMBER 1

DRAWING NUMBER

B

T ROAD PROFILE NUMBER 1

DRAWING NUMBER

B

T STORM DRAIN PROFILE NUMBER 1

DRAWING NUMBER

B

T UTILITY PROFILE NUMBER 1

DRAWING NUMBER

LINETYPE DESCRIPTION

LINETYPES

FORCE MAINFM

FLOODPLAINFP

GAS LINEG

NG

E OVERHEAD ELECTRICAL

TRANSMISSION

UNDERGROUND CABLE TVUGTV

UGT(FO) OVERHEAD FIBER OPTIC

TELEPHONE

BALL VALVE

FIRE HYDRANT ASSEMBLY

CIVIL LEGEND (CONT'D)

ROCK DITCH CHECK

SUMP INLET SEDIMENT FILTER

CURB INLET SEDMIENT FILTER

GRATED INLET

AREA INLET

STANDARD CURB INLET

DOUBLE COMBINATION INLET

EXTENDED THROAT CURB INLET

SYMBOL DESCRIPTION

STAGING AREA

SIDEWALK

PROPOSED ASPHALT/

PAVEMENT REPAIR

EXISTING CONTOURS1300

PROPOSED CONTOURS1300

SPOT ELEVATIONFG - 1300.00

CLEANOUT

B

T PROFILE NUMBER 1

DRAWING NUMBER

SCALE: NONE

05-C305 05-C310

TITLE

TITLE DENOTES A CIVIL PROFILE

AND PLAN VIEW LAYOUT

(THIS EXAMPLE IS PROFILE

NUMBER 1 ON DRAWING NUMBER

05-C310 WHICH HAS A BACK

REFERENCE TO THE PLAN VIEW

LAYOUT ON DRAWING NUMBER

05-C305)

05-C205 05-C210

CALLOUT DENOTES A CUT SECTION

TYPICAL REFERENCE

(THIS EXAMPLE OCCURS ON

DRAWING NUMBER 05-C205

REFERENCING SECTION NUMBER 1

ON DRAWING NUMBER 05-C210)

GUARDRAIL/MASONRY

FENCE

HANDRAIL

VALVE COVERVC

LIFT STATIONLIFT

STA

PULL BOX PULL BOX

MAILBOX

FLAGPOLE

SATELLITE DISH

VENT

PROFILE

APPURTENANCE SYMBOLS

DESCRIPTIONPROFILE

APPURTENANCE SYMBOLS

DESCRIPTION

TRANSFORMERTRANSFORMER

WELLWELL

TRAFFIC CONTROL BOX

TRAFFIC

CONTROL

BOX

WINDSOCK

PUMP STATIONPUMP

STATION

RAILROAD SWITCH BOX

RAILROAD

SWITCH

BOX

SEPTIC TANKSEPTIC

TANK

RIGHT-OF-WAY MARKERR/W

EVERGREEN TREE0"-6"

DIA

PROPOSED HEAVY

DUTY ASPHALT

PROPOSED HEAVY

DUTY CONCRETE

X REMOVE TREE

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-G

3.

dw g L as t S av e:

2/

/2

:5

AM

L as t s av ed b y:

R

G G ar ci a La st p lo tte d by

: M at a, E ric a

Pl ot

S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:2 .5

Pl ot

D at e:

0/

/2

8:

P

M P lo tte r u se d:

N on e

01-G005

LEGEND

C

E

N S

E

D

S

T

A

X

A

S

P

R

O

F

E

S

S

I

O

N

G

I

N

E

E

R

KORY WILKINSON

135779

Digitally Signed 10/28/2024

CALLOUT DENOTES A STANDARD

DETAIL REFERENCE.

POLE MOUNTED LIGHT

EMERGENCY EXIT SIGN WITH

LIGHTS

EMERGENCY EXIT SIGN WITH

DIRECTION

WALL MOUNTED EXTERIOR LIGHT

RECESSED LIGHT

LIGHTING FIXTURE SYMBOLS

X

ELECTRICAL SHEET NOTE

ALL GENERAL NOTES ON THIS SHEET ARE TO BE

APPLIED TO ALL ELECTRICALL DRAWINGS IN THIS SET.

SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET

MAY OR MAY NOT BE USED IN THE CONTAINED

REFERENCE DRAWINGS

LIGHTNING PROTECTION

CONDUCTORS

BELOW GRADE ELECTRICAL

ABOVE GRADE ELECTRICAL

EQUIPMENT PACKAGE

GROUND

GENERAL ELECTRICAL LINE STYLES

WIRE CONTINUATION

SWITCH, SINGLE POLE

SWITCH, FOUR WAY

SWITCH, THREE WAY

SWITCH, DIMMER

LIGHTING SWITCH SYMBOLS

D

RECEPTACLE SYMBOLS

20 AMP DUPLEX RECEPTACLE, MTD.

18" AFF TO BOTTOM, UNLESS NOTED

OTHERWISE, WITH #12 GROUND

WIRE.

"GFCI" INDICATES GROUND FAULT

CIRCUIT INTERRUPTER.

"WP" INDICATES HEAVY-DUTY,

WEATHERPROOF WHILE-IN-USE

ENCLOSURE AND COVER.

DUPLEX FLOOR/CEILING

RECEPTACLE

WP

GFCI

BOX INDICATES FLOOR OUTLET WITH

RECESSED CAST JUNCTION BOX

35-W901

TYP LIGHT FIXTURE

LIGHT FIXTURE WITH

EMERGENCY BATTERY PACK

LIGHT FIXTURE ANNOTATIONS

GENERAL ELECTRICAL SYMBOLS

DUCT-BANK SECTION CUT

#A1 90-E601

SECTION "#"

DUCT BANK TAG "A"

BRANCH "1" OF DUCT BANK "A"

SHEET REFERENCE

HOME RUN TO PANEL IN

DEDICATED CONDUIT,

RECEPTACLES AND EQUIPMENT

SHALL HAVE DEDICATED GREEN

GROUND WIRE.

CONDUIT

TAG

XXXX = PANEL/EQUIPMENT

IDENTIFIER

2(3#14+#14G+4#14SPARE)

DENOTES TWO (2) SETS OF;

THREE (3) NO. 14 AWG

CONDUCTORS

ONE (1) NO. 14 AWG GROUND

CONDUCTOR

FOUR (4) NO. 14 AWG SPARE

CONDUCTORS.

XX = FACILITY NUMBER

Y = ELECTRICAL/CONTROLS

P (480VAC/POWER)

E (240/120VAC/CONTROL)

S (SIGNAL)

H (MEDIUM VOLTAGE)

N (FIBER)

ZZ = SEQUENTIAL NUMBER

A = DUCT BANK PROFILE

LETTER

CONDUIT RUN TAG

## = SEQUENTIAL CIRCUIT

NUMBER

Y = CONDUIT FUNCTION

P = (480VAC POWER)

L = (240/120VAC POWER)

C = (CONTROL/DISCRETE)

S = (SIGNAL/ANALOG)

N = (COMMUNICATION)

CONDUIT WIRE TAG

XXXX-Y##

XXYPBZZA

ELECTRICAL TAGS

PULL BOX TAG

CONDUIT HOME RUN TAG

SECURITY & ACCESS:

DS = DOOR SWITCH

KP = KEY PAD

MD = MOTION DETECTOR

ML = MAGNETIC LOCK

OC = OCCUPANCY SENSOR

PC = PHOTO CELL

WS = WINDOW SWITCH

SURVEILLANCE CAMERA

XX

DATA & COMMUNICATION SYMBOLS

DATA AND TELEPHONE DUAL OUTLET

DATA OUTLET

PHONE OUTLET

TELEVISION OUTLET

GROUND ROD AND TEST WELL

GROUND ROD

LIGHTNING AIR TERMINAL

GROUNDING & LIGHTNING PROTECTION

CONDUIT & CABLE TRAY SYMBOLS

CABLE TRAY BEND

CABLE TRAY JUNCTION / TEE

CABLE TRAY RISE / DROP

CABLE TRAY CROSS FITTING

CONDUIT JUNCTION BOX / TEE /

TAKEOFF

CONDUIT BEND

CABLE TRAY RISE / DROP

CONDUIT JUNCTION BOX / RISE /

DROP

CABLE TRAY TRANSITION / REDUCER

ELECTRICAL EQUIPMENT SYMBOLS

ELECTRICAL PANEL OR EQUIPMENT

CABINET, RECESSED MOUNTED,

5'-6" TO TOP OF ENCLOSURE

ELECTRICAL PANEL OR EQUIPMENT

CABINET, SURFACE MOUNTED, 5'-6"

TO TOP OF ENCLOSURE

J JUNCTION BOXJ

SAFETY NON-FUSED DISCONNECT

SWITCH

SAFETY FUSED DISCONNECT

SWITCHF

CONTROL SCHEMATIC SYMBOLS

SECURITY SYMBOLS

TRANSFORMER, RATINGS AS

SHOWN

SPD SURGE PROTECTION DEVICE

TRANSFER SWITCH

ATS - AUTOMATIC TRANSFER SWITCH

MTS - MANUAL TRANSFER SWITCH

PM

GENERATOR

POWER METER

CIRCUIT BREAKER, RATINGS AS

NOTED.

VARIABLE FREQUENCY DRIVE (VFD)

DISCONNECT

REDUCED VOLTAGE SOFT-START

MOTOR

DRAW OUT CONSTRUCTION

OL

1 FULL VOLTAGE NON-REVERSING

MOTOR STARTER. SIZE AS NOTED.

FV

NR

FV

R

OR

OL

1 FULL VOLTAGE REVERSING MOTOR

STARTER. SIZE AS NOTED.

KEY INTERLOCK

GROUND

OR

FUSED DISCONNECTOR

INDUCTOR/LINE REACTOR

OR

CAPACITOR

L

SHORT TIME

INSTANTANEOUS

GROUND

S

I

G

LONG TIME

MEDIUM VOLTAGE CIRCUIT BREAKER

CURRENT TRANSFORMER

VOLTAGE TRANSFORMER

NO TIME DELAY CLOSE

WHEN ENERGIZED

RELAY COIL

CR - CONTROL RELAY

M - MOTOR STARTER COIL

RELAY CONTACT NC

RELAY CONTACT NO

TIME DELAY RELAY COILTD

NC TIME DELAY OPEN

WHEN ENERGIZED

NO TIME DELAY OPEN

WHEN DE-ENERGIZED

NC TIME DELAY CLOSE

WHEN DE-ENERGIZED

SOLENOID

CR

SWITCH -

THREE POLE

SWITCH - LIMIT NORMALLY OPEN

(NO)

SWITCH - LIMIT NORMALLY OPEN

HELD CLOSED (NOHC)

SWITCH - LIMIT NORMALLY CLOSED

(NC)

SWITCH - LIMIT NORMALLY CLOSED

HELD OPEN (NCHO)

NORMALLY OPEN,

CLOSES ON RISING "B"

NORMALLY CLOSED,

OPENS ON RISING "B"

HELD CLOSED, OPENS

ON DROPPING "B"

HELD OPEN, CLOSES

ON DROPPING "B"

A

A

A

A

A B

PRESSURE

LEVEL

TEMPERATURE

FLOW

WIRING TO FIELD DEVICE

WIRING WITHIN PANEL

ELECTRICAL CONNECTION

TERMINAL BLOCK LOCAL

TERMINAL BLOCK EXTERNAL

ELECTRICALLY CONNECTED

NOT ELECTRICALLY CONNECTEDOR

CIRCUIT BREAKER

SINGLE POLE

CIRCUIT BREAKER

THREE POLE

FUSE, AMPERE RATING AS NOTED

GROUND

FUSED TERMINAL BLOCK, AMPERE

RATING AS NOTED

10A

1A

HS (MOMENTARY) PB NC

HS (MOMENTARY) PB NO

HS (MAINTAINED) PB WITH RED

MUSHROOM HEAD OPERATOR

HS THREE POSITION

X = CLOSED

O = OPENXOO

HS TWO POSITION

OOX

N E

RV

SS

KVAR AS NOTED

HORSEPOWER AS NOTED

MOTOR

OVERLOAD ELECTRONIC

OVERLOAD ELECTRONIC THREE

POLE

OVERLOAD THERMAL

OVERLOAD THERMAL THREE POLE

POTENTIOMETER

ETM ELAPSED TIME METER

HEATER

VFD LINE REACTOR

PILOT LIGHT - COLOR AS INDICATED

A - AMBER

G - GREEN

R - RED

B - BLUE

W - WHITE

A

PTT

PTT - PUSH-TO-TEST

600AF/3P,

LSIG

400AT

40 HP

M

K

M

G

V

F

PHASE GRAPHICS

EXISTING ELEMENTS

NEW ELEMENTS

EXISTING ELEMENTS TO BE

REMOVED/DEMOLISHED

FUTURE CONSTRUCTION NEW

ELEMENT

PM PHASE MONITOR

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: KDW

DATE:

JOB NO.:

DESIGNED BY: ECO

OCT 2024

23W05125

DRAWN BY: EMRGG

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-G

5- G

6.

dw g

L as t S av e:

0/

/2

3:

P

M L as t s av ed b y:

R G

G ar ci a

La st p lo tte d by : M at a, E ric a Pl ot S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :2

.5

Pl ot D at e:

0/

/2

5:

P M

P lo tte r u se d:

N on e

01-G006

ELECTRICAL

SYMBOL

LEGENDS

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F:

E

LO

Y C

. O

LI

VO

P.

E.

O N

O C

TO

BE

R

4.

IT

IS

N O

T

TO

B E

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

BI

D D

IN

G

, O R

P

ER

M

IT

TI

N

G P

U R

PO

SE

S.

KDW

C

E

N S

E

D

S

T

A

X

A

S

P

R

O

F

E

S

S

I

O

N

G

I

N

E

E

R

KORY WILKINSON

135779

Digitally Signed 10/28/2024

ABBREVIATIONSGENERAL NOTES

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

30.

31.

32.

IN AREAS WHERE THERE ARE OVERHEAD BRIDGE CRANES, HOISTS, DOORS OR OTHER SIMILAR

ITEMS, NO CONDUITS SHALL BE INSTALLED IN SUCH A MANNER AS TO CONFLICT WITH PROPER

OPERATION OF SUCH EQUIPMENT.

CONTRACTOR SHALL FURNISH AND INSTALL ITEMS AS NECESSARY FOR COMPLETE AND

FUNCTIONAL SYSTEMS. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONS AND OTHER

SECTIONS OF THE PLANS FOR ITEMS AS MAY BE REQUIRED AND SHALL PROVIDE CONDUIT,

WIRING AND TERMINATIONS FOR ALL ITEMS AS REQUIRED.

CONTRACTOR SHALL REFER TO OTHER PLAN SHEETS FOR LOCATIONS OF FIREWALLS. ALL

CONDUIT PENETRATIONS IN THESE WALLS SHALL BE ACCOMPLISHED IN SUCH A MANNER AS TO

NOT REDUCE THE RATING OF THE FIREWALL THROUGH THE USE OF BOXES, SEALANTS AND

OTHER ACCESSORIES AS MAY BE REQUIRED.

CONTRACTOR SHALL REFER TO MECHANICAL PLAN SHEETS AND SPECIFICATIONS FOR ITEMS

RELATED TO THE MECHANICAL SYSTEMS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR

INSTALLING ALL ITEMS AS NECESSARY FOR COMPLETE AND OPERABLE MECHANICAL HEREIN

INCLUDING, BUT NOT LIMITED TO; CONTROL POWER TRANSFORMERS, STARTERS, THERMOSTATS, CONTROL STATIONS, AND OTHER ELECTRICAL ITEMS AS RELATED TO THE INSTALLATION OF THE

MECHANICAL SYSTEMS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING DISCONNECTS FOR ALL

MECHANICAL MOTORS UNLESS THE EQUIPMENT IS FURNISHED WITH AN INTEGRAL DISCONNECT

FROM THE MANUFACTURER. IN ADDITION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR

PROVIDING ALL CONDUIT, WIRING AND TERMINATIONS FOR ALL COMPONENTS AS MAY BE

NECESSARY FOR THE MECHANICAL SYSTEMS.

ALL RECEPTACLES IN OUTDOOR AND ANTICIPATED WET AREAS SHALL BE GROUND FAULT

CIRCUIT INTERRUPTER RECEPTACLES WITH HEAVY-DUTY WEATHERPROOF COVERS.

EQUIPMENT LOCKOUTS SHALL BE IN STRICT ACCORDANCE WITH OWNER'S REQUIREMENTS.

ALL CONDUITS SHALL HAVE A GROUNDING CONDUCTOR, SIZED PER NEC.

ALL LIGHTING FIXTURES INSTALLED IN INSULATED LOCATIONS SHALL BE RATED FOR SUCH

INSTALLATION REGARDLESS OF THE FIXTURE SCHEDULE DESIGNATION.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF NEW SERVICE

INSTALLATIONS WITH OWNER, ENGINEER AND SERVICE UTILITY. THE CONTRACTOR SHALL

FURNISH AND INSTALL ALL ITEMS AS REQUIRED BY SERVICE UTILITY FOR NEW SERVICE

CONNECTIONS.

UNLESS NOTED OTHERWISE, ALL CONTROL PANELS SHALL BE FABRICATED SUCH THAT ALL

OPERATORS AND INDICATING DEVICES INDICATED ON THE SCHEMATICS BE LOCATED ON THE

FRONT DOOR OR COVER OF THE PANEL. OPERATING AND INDICATING DEVICES SHALL BE VISIBLE

AND OPERABLE WITHOUT HAVING TO OPEN THE CONTROL PANEL UNLESS OTHERWISE

IDENTIFIED ON THE DRAWING.

DUCT BANKS INDICATED AND THE BELOW GRADE CONDUIT ROUTING AS SHOWN IS

DIAGRAMMATIC IN NATURE AND SHOWN FOR REFERENCE ONLY. THE CONTRACTOR SHALL

REVIEW PLAN SHEETS RELATED TO INDIVIDUAL STRUCTURES AND VERIFY CONDUITS THAT MAY

BE REQUIRED. THE CONTRACTOR SHALL VERIFY NUMBER OF CONDUITS AS INDICATED IN THE

DUCT BANK PRIOR TO INSTALLATION WITH THE ENGINEER. PROVIDE AT A MINIMUM ONE SPARE CONDUIT EQUAL IN SIZE TO THE LARGEST CONDUIT IN USE, IN EACH DUCT BANK. FOR EACH SET

OF FOUR USED CONDUITS IN EACH DUCT BANK PROVIDE A SPARE CONDUIT EQUAL TO THE

LARGEST CONDUIT IN USE: (1-4 CONDUITS, 1 SPARE; 5-8 CONDUITS, 2 SPARE; AND SO ON).

THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING HEAT TRACING FOR ALL EXPOSED

WATER LINES TO BE INSTALLED UNDER THIS PROJECT. THE CONTRACTOR SHALL REVIEW OTHER

SECTIONS OF THE PLANS AND SPECS AND PROVIDE SUITABLE HEAT TRACING COMPONENTS AS

MAY BE REQUIRED, WHETHER INDICATED ON THE ELECTRICAL PLAN SHEETS OR NOT.

VERIFY LOCATION OF ALL LIGHTING FIXTURES WITH OWNER AND ENGINEER PRIOR TO

INSTALLATION. COORDINATE LIGHT FIXTURE LOCATIONS AND MOUNTING HEIGHTS WITH HVAC

DUCTS AND OVERHEAD CONDUIT RUNS. USE RIGID CONDUIT WHEN SUSPENDING LIGHT FIXTURES

TO PREVENT SWAYING.

USE CRIMPED OR BOLTED CONNECTIONS FOR ALL BONDING CONNECTIONS BETWEEN

CONDUCTORS AND BUILDING SYSTEM COMPONENTS. USE EXOTHERMIC WELDED CONNECTIONS

FOR ALL UNDERGROUND PORTIONS OF THE GROUNDING SYSTEM WITH THE EXCEPTION OF

GROUND ROD TEST WELLS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

THESE NOTATIONS ARE INTENDED TO BE GENERAL IN NATURE. THEY MAY OR MAY NOT APPLY

TO SOME OR ALL OF THE PLAN SHEETS AND SPECIFICATIONS.

CONDUIT RUNS INDICATED ON THE PLAN SHEETS ARE INTENDED TO BE SCHEMATIC ONLY.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD ROUTING ALL CONDUIT RUNS AND

SHALL COORDINATE ANY DEVIATION FROM ROUTING AS INDICATED HEREIN WITH THE

ENGINEER. ALL CONDUIT SHALL BE INSTALLED IN SUCH A MANNER AS TO PREVENT

CONFLICTS WITH EQUIPMENT. EXPOSED CONDUIT SHALL BE INSTALLED PARALLEL OR

PERPENDICULAR TO BEAMS OR STRUCTURAL CONDITIONS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD ROUTING ALL CONDUITS NOT

INDICATED ON THE PLAN SHEETS. THIS INCLUDES CIRCUITS FOR LIGHTING, RECEPTACLES

AND OTHER MISCELLANEOUS EQUIPMENT CIRCUITS.

ALL CONDUITS SHALL BE ROUTED AND SUPPORTED IN SUCH A MANNER AS TO NOT

COMPROMISE THE STRUCTURAL INTEGRITY OF WALLS, FLOORS, CEILINGS, AND ROOFS.

WHERE REQUIRED, THE CONTRACTOR SHALL PROVIDE ADDITIONAL STRUCTURAL

SUPPORTING MEMBERS FOR THE INSTALLATION AND SHALL COORDINATE SUCH MEMBERS

WITH ENGINEER.

ALL SURFACE MOUNTED PANELS AND PANELBOARDS ON THE INTERIOR OF EXTERIOR WALLS

OR IN OTHER LOCATIONS CONSIDERED DAMP OR WET SHALL BE MOUNTED SO AS TO

MAINTAIN A 1/4" MINIMUM AIR SPACE BETWEEN THE ENCLOSURE AND THE WALL.

PULLBOXES, IF SHOWN ON THE PLANS, ARE SCHEMATIC IN NATURE. THE CONTRACTOR SHALL

PROVIDE ADDITIONAL PULLBOXES WHERE REQUIRED TO MAKE A WORKABLE INSTALLATION.

ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE SPECIFICATIONS WHETHER OR

NOT THEY ARE REFERENCED ON THE DRAWINGS.

ALL CONDUIT RUNS PASSING THROUGH EXPANSION JOINTS SHALL HAVE EXPANSION OR

EXPANSION AND DEFLECTION TYPE FITTINGS. FOR LOCATIONS OF EXPANSION JOINTS, REFER

TO THE STRUCTURAL DRAWINGS.

THE WIRING DIAGRAMS, QUANTITY AND SIZE OF WIRES AND CONDUITS REPRESENT

SUGGESTED ARRANGEMENT BASED UPON SELECTED STANDARD COMPONENTS OF

ELECTRICAL EQUIPMENT. IF EQUIPMENT SUPPLIED BY THE MANUFACTURER HAS A LARGER

LOAD THAN THE VALUE SHOWN OR INDICATED, THE CABLE, CONDUIT AND ELECTRICAL

EQUIPMENT MAY BE ENLARGED AS REQUIRED TO ACCOMMODATE THE HIGHER LOADING.

HOWEVER, THE BASIC SEQUENCE AND METHOD OF CONTROL MUST BE MAINTAINED AS

INDICATED ON THE DRAWINGS AND/OR SPECIFICATIONS.

ALL MOTOR STARTER CONTROL POWER TRANSFORMERS SHALL BE SIZED TO PROVIDE

SUFFICIENT VOLT-AMPERE CAPACITY FOR OPERATING ALL LOCAL AND REMOTE ELECTRICAL

DEVICES ASSOCIATED WITH CONTROL OF THE MOTOR IN ADDITION TO THE STARTER COIL.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL LOADING REQUIREMENTS

FOR CONTROL POWER TRANSFORMERS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING PROPERLY SIZED STARTER

OVERLOADS FOR ALL EQUIPMENT INSTALLED.

MOTOR CONTROL CENTERS AND ALL FREE STANDING PANELS SHALL BE SET ON CONCRETE

HOUSEKEEPING PADS.

IN GENERAL, SEPARATE POWER, CONTROL AND SIGNAL WIRING. PROVIDE SEPARATE

CONDUIT, PULL AND JUNCTION BOXES. PROVIDE SUITABLE CABLE BARRIER WITHIN PULL OR

JUNCTION BOXES WHERE SEPARATION OF WIRING IS NOT SHOWN ON THE DRAWINGS.

CONTROL AND SIGNAL CONDUCTORS OF LIKE VOLTAGES MAY BE COMBINED INTO A SINGLE

CONDUIT, AS LONG AS NEC CONDUIT FILL REQUIREMENTS ARE MET.

UNLESS OTHERWISE NOTED ALL CONDUIT TO BE ROUTED EXPOSED. ALL EXPOSED CONDUIT

AND PORTIONS OF THE CONDUIT SYSTEM SHALL BE SURFACE MOUNTED. SEE

SPECIFICATIONS FOR CONDUIT, BOXES, SUPPORTS, HANGAR, UNISTRUT AND OTHER

PORTIONS OR THE CONDUIT SYSTEM MATERIAL REQUIREMENTS.

VERIFY LOCATION OF ALL EQUIPMENT PRIOR TO INSTALLATION.

PROVIDE SEPARATE CONDUITS FOR 480VAC POWER CIRCUITS. SIGNAL AND CONTROL

CONDUCTORS OF LIKE VOLTAGES MAY BE COMBINED IN A SINGLE CONDUIT WHERE

COMPLIANT WITH NEC CONDUIT FILL REQUIREMENTS.

CONTRACTOR TO SUBMIT CONDUIT ROUTING PLANS TO ENGINEER PRIOR TO

CONSTRUCTION.

A, AMP

AC

AF

AFF

AIC

AM

ARMS

AT

ATS

AWG

BFI

C

CAS

CB

CCTV

COM

CP

CPT

CR

CRI

CT

DB

DC

DISC

DP

DWG

EF

EG

EMT

ENCL

ETM

FACP

FDS

FLA

FOC, FO

FRP

FS

FVNR

FVR

G, GEN

GDT

G, GND

GRS

HH

HID

HMI

HOR

HR

HS

HV

HZ

IG

JB

KAIC

KVAR

KWH

L

LA

LCP

LLF

LOR

LP

LRA

LV

MCA

MCB

MCC

MCP

MH

AMPERES

ALTERNATING CURRENT

AMP FRAME

ABOVE FINISHED FLOOR

AMPS INTERRUPTING CAPACITY

AMP-METER

ARC REDUCTION MAINTENANCE SWITCH

AMP TRIP

AUTOMATIC TRANSFER SWITCH

AMERICAN WIRE GAUGE

BLOWN FUSE INDICATOR

CONDUIT, CONTROL/DISCRETE CIRCUIT

CONTROL AND STATUS RELAY

CIRCUIT BREAKER

CLOSED CIRCUIT TELEVISION

COMMON

CONTROL PANEL

CONTROL POWER TRANSFORMER

CONTROL RELAY

COLOR RENDERING INDEX

CURRENT TRANSFORMER

DECIBEL

DIRECT CURRENT

DISCONNECT

DISTRIBUTION PANEL

DRAWING

EXHAUST FAN

EQUIPMENT GROUND

ELECTRICAL METALLIC TUBING

ENCLOSURE

ELAPSED TIME METER

FIRE ALARM CONTROL PANEL

FUSED DISCONNECT SWITCH

FULL LOAD AMPERES

FIBER OPTIC CABLE

FIBERGLASS REINFORCED POLYESTER

FLOAT SWITCH

FULL VOLTAGE NON-REVERSING STARTER

FULL VOLTAGE REVERSING STARTER

GENERATOR

GRAPHIC DISPLAY TERMINAL

GROUND

GALVANIZED RIGID STEEL

HANDHOLE

HIGH INTENSITY DISCHARGE

HUMAN MACHINE INTERFACE

HAND-OFF-REMOTE

HOUR

HAND SWITCH

HIGH VOLTAGE

HERTZ

ISOLATED GROUND

JUNCTION BOX

KILOAMP INTERRUPTING CAPACITY

KILOVOLT-AMPERE, REACTIVE

KILOWATT-HOUR

240/208/120VAC CIRCUIT

LIGHTNING ARRESTER

LOCAL CONTROL PANEL

LIGHT LOSS FACTOR

LOCAL-OFF-REMOTE

LIGHTING PANEL

LOCKED ROTOR AMPERES

LOW VOLTAGE

MINIMUM CIRCUIT AMPACITY

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MOTOR CIRCUIT PROTECTOR

MANHOLE

MLO

MOCP

MS

MTD

MV

N

NC

NCHC

NCTC

NCTO

NEC

NEMA

NEUT

NFDS

NO

NOHC

NOTC

NOTO

OHE

OIT

OL

OOR

P

PP

PB

PCC

PEC

PF

PFCC

PH, Ø

PL

PM

PTT

RECPT

RVAT

RVSS

S

SS

SA

SDBC

SE

SPD

SSOL

STP

SV

SW

SWB, SWBD

SWGR

T, XFMR

TC

TD

TEL

THD

TM

UG

UGE

UH

UL

UTP

V

VAC

VFD, V

VM

WH

WM

WP

1P 3P

MAIN LUG ONLY

MAXIMUM OVER CURRENT PROTECTION

MOTOR STARTER

MOUNTED

MEDIUM VOLTAGE

COMMUNICATION CIRCUIT

NORMALLY CLOSED

NORMALLY CLOSED HELD OPEN

NORMALLY CLOSED TIMED CLOSED

NORMALLY CLOSED TIMED OPEN

NATIONAL ELECTRICAL CODE

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NEUTRAL

NON-FUSED DISCONNECT SWITCH

NORMALLY OPEN

NORMALLY OPEN HELD CLOSED

NORMALLY OPEN TIMED CLOSED

NORMALLY OPEN TIMED OPEN

OVERHEAD ELECTRIC

OPERATOR INTERFACE TERMINAL

OVERLOAD

ON-OFF-REMOTE

480VAC POWER CIRCUIT, POLE

POWER PANEL

PUSH BUTTON OR PULLBOX

POINT OF COMMON COUPLING

PHOTO ELECTRIC CELL

POWER FACTOR

POWER FACTOR CORRECTION CAPACITOR

PHASE

PILOT LIGHT

PHASE MONITOR

PUSH-TO-TEST

RECEPTACLE

REDUCED VOLTAGE AUTO-TRANSFORMER

REDUCED VOLTAGE SOFT STARTER

SECOND, SIGNAL/ANALOG CIRCUIT

STAINLESS STEEL

SURGE ARRESTER

SOFT DRAWN BARE COPPER

SERVICE ENTRANCE

SURGE PROTECTION DEVICE

SOLID STATE OVERLOAD RELAY

SHIELDED TWISTED PAIR

SOLENOID VALVE

SWITCH

SWITCHBOARD

SWITCHGEAR

TRANSFORMER

TIME CLOCK

TIME DELAY

TELEPHONE

TOTAL HARMONIC DISTORTION

THERMAL MAGNETIC TRIP

UNDERGROUND

UNDERGROUND ELECTRIC

UNIT HEATER

UNDERWRITERS LABORATORIES, INC

UNSHIELDED TWISTED PAIR

VOLTS

VOLTAGE ALTERNATING CURRENT

VARIABLE FREQUENCY DRIVE

VOLT-METER

WEATHER HEAD

WATT METER

WEATHERPROOF

SINGLE POLE

THREE POLE

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY:

DATE:

JOB NO.:

DESIGNED BY: ECO

OCT 2024

23W05125

DRAWN BY: EMRGG

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-G

5- G

6.

dw g

L as t S av e:

0/

/2

3:

P

M L as t s av ed b y:

R G

G ar ci a

La st p lo tte d by : M at a, E ric a Pl ot S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :2

.5

Pl ot D at e:

0/

/2

8:

P M

P lo tte r u se d:

N on e

01-G007

ELECTRICAL

NOTES AND

ABBREVIATIONS

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F:

E

LO

Y C

. O

LI

VO

P.

E.

O N

O C

TO

BE

R

4.

IT

IS

N O

T

TO

B E

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

BI

D D

IN

G

, O R

P

ER

M

IT

TI

N

G P

U R

PO

SE

S.

KDW

C

E

N S

E

D

S

T

A

X

A

S

P

R

O

F

E

S

S

I

O

N

G

I

N

E

E

R

KORY WILKINSON

135779

Digitally Signed 10/28/2024

OHE

OHE

OHE

OHE

OHE

OHE

# B-05

100058100158

# B-03

# B-04

# B-06

# B-07

# B-08

# B-09

# B-10

10+00

+00 20+00

25+00

30+00

35+00

40+00

45+00

50+00

+0

60+00

65+00 70+00 75+00 80+00

85+00

90+00

95+00

0+

5+

8+

SURVEY CONTROL

POINT #

100058

100158

NORTHING

6946955.00

6946733.87

6946389.98

6946029.63

6945678.48

6945498.28

6945939.90

6945900.33

6945950.68

6946152.42

6945972.45

6946262.24

6946531.06

6946773.65

6946838.43

6946994.76

6947259.64

6947353.72

6947695.84

6947944.11

6948435.56

6948608.78

6948739.86

6948860.79

6948989.87

6949146.76

6949313.51

6949502.14

6949328.02

6949209.19

6948194.23

6945950.68

6945939.81

EASTING

2568289.64

2568054.43

2567691.57

2567344.62

2566860.94

2566600.91

2566181.58

2565656.07

2565292.96

2564291.59

2564728.21

2564157.91

2564084.53

2564421.20

2564127.91

2563978.68

2563787.44

2563649.64

2563316.76

2563075.42

2562587.60

2562421.09

2562282.16

2562143.17

2561989.79

2561856.45

2561716.30

2561467.63

2561289.01

2561191.01

2562796.85

2565292.96

2564900.46

ELEVATION

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

411.62

403.15

408.80

412.03

411.95

415.29

417.63

422.55

424.80

426.31

427.73

426.02

428.91

431.37

431.06

432.90

440.01

419.18

0.00

0.00

DESCRIPTION

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING" YC

CP 1/2" CIRS "YR MAPPING"

CP 1/2" CIRS "YR MAPPING"

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-G

8- .d w g

L as t S av e:

0/

/2

2:

P

M L as t s av ed b y:

E M at a

La st p lo tte d by : M at a, E ric a Pl ot S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :2

.5

Pl ot D at e:

0/

/2

8:

P M

P lo tte r u se d:

N on e

01-G008

PROJECT CONTROL &

BORE LOCATIONS

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

INTERSTATE HIGHWAY 20

LA

W

SON R

D.

MILAM RD.

MCKENZIE RD.

LUMLEY RD.

FUTURE ONCOR

TRANSMISSION

MAIN

(IN FEET)

0 150' 300' 600' 900'

N

NOTES

1. COORDINATES ARE BASED ON THE TEXAS STATE PLANE

COORDINATE SYSTEM, NORTH CENTRAL ZONE (4202) AND

SCALED TO SURFACE BY USING THE CITY OF PLANO GRID

TO SURFACE FACTOR OF 1.000136506 (0,0 BASE POINT).

ELEVATIONS ARE BASED ON THE NORTH AMERICAN DATUM

OF 1988 (NAVD88) USING GEOID18.

2. TOPOGRAPHIC SURVEY DATA SHOWN HEREON IS BASED

ON AN ON-THE-GROUND SURVEY PERFORMED BY YELLOW

ROSE MAPPING, LLC ON SEPTEMBER 22 - NOVEMBER 27,

2023.

C

E

N S

E

D

S

T

A

X

A

S

P

R

O

F

E

S

S

I

O

N

G

I

N

E

E

R

KORY WILKINSON

135779

Digitally Signed 10/28/2024

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-0 1-

G

6.

dw g L as t S av e:

/1

2/

2:

P M

L as t s av ed b y:

E

M at a La st p lo tte d by

: M at a, E ric a

Pl ot

S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:2 .5

Pl ot

D at e:

0/

/2

8:

P

M P lo tte r u se d:

N on e

01-G009

GEOTECHNICAL

BORING LOGS 1

B O

R

IN

G L

O G

S A

R E

E X

TR

A

C

TE

D F

R O

M T

H E

G E

O

TE

C H

N

IC

A L

E N

G

IN

E E

R

IN

G S

TU

D

Y D

A

TE

D D

E C

E M

B E

R

1, P E

R

FO

R M

E D

B Y

E C

S S

O U

TH

W

E S

T, L

LP

A

N D

S E

A

LE

D B

Y S

R I D

IN

A

K A

R A

N

TX

P

E

4)

TH

E

F U

LL

G

E O

TE

C

H N

IC

A

L E

N G

IN

E

E R

IN

G

S

TU

D Y

IS

IN

C

LU

D E

D

IN

T H

E P

R O

JE

C

T S

P E

C

IF

IC

A

TI

O

N S

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

J U

N E

. T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

B

E U

SE

D

F O

R C

O N

ST

R

U C

TI

O

N , B

ID

D

IN

G

, O R

PE

R

M

IT

TI

N

G P

U R

PO

SE

S.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

B O

R

IN

G L

O G

S A

R E

E X

TR

A

C

TE

D F

R O

M T

H E

G E

O

TE

C H

N

IC

A L

E N

G

IN

E E

R

IN

G S

TU

D

Y D

A

TE

D D

E C

E M

B E

R

1, P E

R

FO

R M

E D

B Y

E C

S S

O U

TH

W

E S

T, L

LP

A

N D

S E

A

LE

D B

Y S

R I D

IN

A

K A

R A

N

TX

P

E

4)

TH

E

F U

LL

G

E O

TE

C

H N

IC

A

L E

N G

IN

E

E R

IN

G

S

TU

D Y

IS

IN

C

LU

D E

D

IN

T H

E P

R O

JE

C

T S

P E

C

IF

IC

A

TI

O

N S

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

Fi le

: L :\2

3\

W

- M es qu ite M cK en zi e-

La w so n

R d

In te rc ep to r\D ra w in gs

\M L_

S& D

-0 1-

G

6.

dw g L as t S av e:

/1

2/

2:

P M

L as t s av ed b y:

E

M at a La st p lo tte d by

: M at a, E ric a

Pl ot

S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:2 .5

Pl ot

D at e:

0/

/2

8:

P

M P lo tte r u se d:

N on e

01-G010

GEOTECHNICAL

BORING LOGS 2

B O

R

IN

G L

O G

S A

R E

E X

TR

A

C

TE

D F

R O

M T

H E

G E

O

TE

C H

N

IC

A L

E N

G

IN

E E

R

IN

G S

TU

D

Y D

A

TE

D D

E C

E M

B E

R

1, P E

R

FO

R M

E D

B Y

E C

S S

O U

TH

W

E S

T, L

LP

A

N D

S E

A

LE

D B

Y S

R I D

IN

A

K A

R A

N

TX

P

E

4)

TH

E

F U

LL

G

E O

TE

C

H N

IC

A

L E

N G

IN

E

E R

IN

G

S

TU

D Y

IS

IN

C

LU

D E

D

IN

T H

E P

R O

JE

C

T S

P E

C

IF

IC

A

TI

O

N S

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

J U

N E

. T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

B

E U

SE

D

F O

R C

O N

ST

R

U C

TI

O

N , B

ID

D

IN

G

, O R

PE

R

M

IT

TI

N

G P

U R

PO

SE

S.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

B O

R

IN

G L

O G

S A

R E

E X

TR

A

C

TE

D F

R O

M T

H E

G E

O

TE

C H

N

IC

A L

E N

G

IN

E E

R

IN

G S

TU

D

Y D

A

TE

D D

E C

E M

B E

R

1, P E

R

FO

R M

E D

B Y

E C

S S

O U

TH

W

E S

T, L

LP

A

N D

S E

A

LE

D B

Y S

R I D

IN

A

K A

R A

N

TX

P

E

4)

TH

E

F U

LL

G

E O

TE

C

H N

IC

A

L E

N G

IN

E

E R

IN

G

S

TU

D Y

IS

IN

C

LU

D E

D

IN

T H

E P

R O

JE

C

T S

P E

C

IF

IC

A

TI

O

N S

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

J U

N E

. T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

B

E U

SE

D

F O

R C

O N

ST

R

U C

TI

O

N , B

ID

D

IN

G

, O R

PE

R

M

IT

TI

N

G P

U R

PO

SE

S.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

B O

R

IN

G L

O G

S A

R E

E X

TR

A

C

TE

D F

R O

M T

H E

G E

O

TE

C H

N

IC

A L

E N

G

IN

E E

R

IN

G S

TU

D

Y D

A

TE

D D

E C

E M

B E

R

1, P E

R

FO

R M

E D

B Y

E C

S S

O U

TH

W

E S

T, L

LP

A

N D

S E

A

LE

D B

Y S

R I D

IN

A

K A

R A

N

TX

P

E

4)

TH

E

F U

LL

G

E O

TE

C

H N

IC

A

L E

N G

IN

E

E R

IN

G

S

TU

D Y

IS

IN

C

LU

D E

D

IN

T H

E P

R O

JE

C

T S

P E

C

IF

IC

A

TI

O

N S

10+00

+00 20+00

25+00

30+00

35+00

40+00

45+00

50+00

+0

60+00

65+00 70+00 75+00 80+00

85+00

90+00

95+00

0+

5+

8+

05-C301

05-C303

05-C304

05-C305

05-C306

05-C307

05-C308

05-C309

05-C310

05-C311

05-C312 05-C313 05-C314 05-C315

05-C316

05-C317

-C

-C

-C

-C

TH

IS

D O

C U

M

EN

T

IS

R

EL

EA

SE

D F

O R

T H

E

PU

R

PO

SE

O

F

IN

TE

R

IM

R

EV

IE

W U

N D

ER

T

H E

AU

TH

O R

IT

Y

O F

KO

R

Y D

. W

IL

KI

N

SO

N

, P .E

. 1

O N

O C

TO

BE

R

4.

T H

IS

D

O C

U M

EN

T

IS

N

O T

TO

BE

U

SE

D F

O R

C O

N

ST

R U

C

TI

O N

, B

ID

D

IN

G , O

R

PE

R M

IT

TI

N G

P U

R

PO

SE

S.

M

ES

Q U

IT

E

M C

KE

N

ZI

E

- L

AW

SO

N

R D

IN

TE

R C

EP

TO

R

IM

PR

O

VE

M

EN

TS

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2024 GARVER, LLC

C

IT

Y O

F M

ES

Q

U

IT

E M

ES

Q

U

IT

E, T

EX

AS

REGISTRATION NO.

F-5713

0%

- P

RE

LIM

IN

AR

Y D

ES

IG

N

NO

T F

OR

C

ON

ST

RU

CT

IO

N

CHECKED BY: PMB

DATE:

JOB NO.:

DESIGNED BY: KDW

OCT 2024

23W05125

DRAWN BY: EM

INTERSTATE HIGHWAY 20

LA

WSON R

D.

MILAM RD.

MCKENZIE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .