The document is a Request for Proposals (RFP) issued by the Town of Breckenridge, Colorado, soliciting qualified Construction Management General Contractor (CM/GC) services for the Timberline Learning Center expansion project. The project involves remodeling and expanding an existing childcare center, with the successful contractor responsible for providing pre-construction services during design development and construction document phases to establish a Guaranteed Maximum Price. The total project budget is $650,000, with construction and design costs covering the building and associated sitework. The RFP was released in February 2024, with proposals due by 12:00 p.m. MST on March 11, 2024. The architectural and engineering team includes EUA for building design and Alpine Engineering for utility, grading, landscaping, and site planning. The estimated construction phase is scheduled from May 2024 to November 2024.
The project will involve expanding the current 3,300 square foot facility, which currently has a capacity of 68 children across six classrooms. As of June 2022, there were 520 children on the waitlist for childcare in Breckenridge, with the highest need being infant and toddler care. The CM/GC will be expected to provide detailed cost estimates, value engineering options, input on long-lead construction items, and administer the subcontract bid process for civil site work and vertical construction. The contractor will also evaluate the cost implications of constructing buildings individually versus constructing all at once, and provide an opinion on potential savings. The civil site work will include utility, drainage, grading, landscaping, and hardscape improvements. The Town reserves the right to not proceed with Phase Two (construction) if deemed not in their best interest.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Town of Breckenridge
Timberline Learning Center - Expansion
Construction Management General Contractor
REQUEST FOR PROPOSALS
February 2024
Request for Proposals
Timberline Learning Center – Expansion
SECTION I: TERMS AND CONDITIONS
1. Invitation
Qualified individuals, firms or consortiums are invited to submit a proposal to the Town of Breckenridge (“hereinafter referred to as “OWNER”) for Construction Management General Contractor (CM/GC) services for the remodel and expansion of the Timberline Learning Childcare Center.
The successful CM/GC will provide Pre-Construction services during the design development and construction document phases to establish a Guaranteed Maximum Price. Construction and design costs for the building and associated sitework are currently budgeted at $650,000. The Architect/Engineering team for this project is led by EUA for building design and Alpine Engineering, Inc for the utility, grading, landscaping, and site planning.
The purpose of this solicitation is to bind a competent, experienced contractor into a formal Agreement with the OWNER to perform the work described in this Request for Proposals and the attachments hereto.
Proposers are cautioned to read the entire Request for Proposals, noting all submittal requirements, including both substance and format. Failure to provide all requested information in the manner required might be cause for rejection of proposal at the sole discretion of the OWNER.
This invitation should not to be construed as a commitment of any kind on the part of the OWNER, nor does it commit the OWNER to pay for any costs incurred in the submission of a proposal package, nor for any costs incurred prior to the execution of a formal Agreement.
2. Procurement Schedule
To be considered, proposals must be received by the OWNER before 12:00 p.m. (noon) MST on Monday March 11, 2024 at: melaniel@townofbreckenridge.com
Alternatively, proposals may be delivered in person to:
Town of Breckenridge c/o Town Clerk Attn: Housing Divison P.O. Box 168 150 Ski Hill Road Breckenridge, CO 80424
Any proposal received after that time shall not be considered, but shall be returned unopened to the proposer. Prospective proposers are advised that the OWNER shall make a good faith effort to adhere to the following schedule for this procurement:
mailto:melaniel@townofbreckenridge.com
• Procedural and technical questions are to be submitted no later than February 29, 2024, at 5:00 p.m. to:
Melanie Leas Town of Breckenridge
Housing Division melaniel@townofbreckenridge.com
However, OWNER shall be under no obligation to comply with the schedule shown above, provided that all prospective proposers or other interested parties known to the OWNER shall be notified equally of changes made to this schedule by the OWNER within a reasonable time after such changes are made. In no event shall any proposer have any redress to the OWNER, be it financial or otherwise, in the event that the OWNER alters this schedule in any way. Responsibility for submitting the proposal to the OWNER on or before the above stated time shall remain solely and strictly that of the proposer. The OWNER shall in no way be responsible for delays in the delivery of any proposal by U.S. mail or any other method of conveyance. The OWNER shall not be responsible for premature opening of proposals that are not marked properly as described above.
3. Form of Response
This subsection contains detailed instructions to which proposers must adhere in the preparation and submittal of proposals to the OWNER.
Proposal: The proposer shall provide 1 digital PDF format version of the proposal to OWNER by the date and time shown in the above schedule unless otherwise notified by the OWNER.
Proposers are advised that proposal content and completeness are most important, and that clear and effective presentations are preferred, with unnecessarily elaborate, decorative or extraneous materials discouraged. The proposal shall be submitted on plain 8.5" by 11" paper single-spaced and using full margins, except as desired by the proposer for emphasis or effect. The proposal shall be limited to a maximum of 20 pages which may be double sided. Each section within the proposal shall be clearly defined for easy reference.
The proposal shall contain the following information and attachments:
Cover Letter: Identify the proposer’s name, mailing address, telephone number and contact person(s). The letter must be signed by the proposer, and should be limited to two (2) pages.
Consortiums, joint ventures or teams submitting proposals, although permitted and encouraged, will not be considered to be responsive unless it is established that all contractual responsibility shall rest solely with one firm or one legal entity, which shall not be a subsidiary or affiliate with limited resources. Indicate the entity responsible for execution on behalf of the team.
Organizational Information: Provide a statement of the proposer’s corporate status and background, including but not necessarily limited to the following: Legal status; organizational structure; current list of owners, officers and principals; management philosophy; brief history;
mailto:melaniel@townofbreckenridge.com type(s) of business conducted; business locations and facilities; customer base; and ability to obtain the required insurance.
References: List projects which included construction experience with building remodeling, additions, expansions and projects constructed in a high alpine environment within the past (5) years. Include references from Owners and Architects, with names and telephone numbers.
List any other projects similar in size, preferably in Colorado mountain towns that have been constructed by the proposer. Provide the following information for each reference:
Client Name: ______________________________________
Address: ______________________________________
Contact Person: __________________________Telephone: (___) _____________
Project Dates: _______________________________
Project Description ________________________________________________
Original Project Budget: ______________________________
Final Project Cost: ______________________________
Explanation of variation from original budget to final project cost:
Construction Manager / General Contractor (CM/GC) and Personnel: Describe the qualifications, experience, and availability of the proposer’s candidate for project manager, project superintendent and supervising personnel. Proposers are advised that failure to provide the individuals selected as project manager and project superintendent as indicated in the proposal may constitute cause for cancellation of contract award or termination of any Agreement between the OWNER and the proposer. Additionally, describe the key personnel who will contribute to the Project, including project managers and superintendents with appropriate expertise in related construction projects.
Such descriptions shall include, but not necessarily be limited to name and job title, years of experience, qualifications, expertise, and availability. Include resumes as available. Include information on how CM/GC communicate and relay information to the team, and how they may be proactive in collaboratively solving project issues.
Project Approach: Describe the approach that the proposer would take in constructing the project to meet the OWNER needs. Project approach should be concise. Processes and elements should be detailed in this section of the proposal. Any other creative or innovative ideas should be detailed in this section.
Project Schedule: The Contractor shall provide an estimated construction schedule that includes constraints, critical issues, meeting dates, review periods and delivery. The Contractors estimated schedule shall be used as the basis for the General Conditions Fee. Time is of the essence for this contract. Liquidated damages will be assessed if project is not finished during the contract time.
Below is a list of approximate milestone dates developed by the Owner.
Advertisement for CM/GC February 1, 2024 Procedural and Technical Questions February 29, 2024, 5pm CM/GC RFP Deadline March 11, 2024, 12:00 noon CM/GC Interviews March 20 or March 21, 2024 Estimated Construction Phase May 2024 – November 2024
Fee Schedule: Proposal shall include a:
• Fee for General Conditions (specify items plus Attachment A minimum)
• Fixed Fee for Pre-Construction Services (design review and cost estimating)
• Percent or Fixed Fee of Contract for Construction Services (overhead and profit)
• Fee or sub-contractor mark-up for Construction Change Orders
• Fee for any other service proposed by or required by the Contractor to complete the project
• Preliminary construction budget based upon the provided construction documents
• Preliminary schedule including construction commencement and key project milestones
At the OWNER’s option, the fees proposed for General Conditions, Construction Services and other services will be used to enter into a construction contract with the selected proposer.
Pre-Construction fee shall include design review, attendance at design meetings, construction schedule preparation and cost estimating during the schematic and design development and construction document phases.
General Conditions fee shall also show items included and excluded in the costs. At a minimum General Conditions shall include those items listed in Attachment A.
Change Order fee shall be defined for both increases or decreases to the Guaranteed Maximum Price.
Construction Services fee shall be for overhead and profit.
The Proposer shall identify any Additional Services available and their associated costs.
The Proposer shall identify any other required services and associated costs not included above that the Proposer believes necessary to successfully complete the project.
Each proposer shall certify that its price proposal shall remain valid for a period of at least one hundred and twenty (120) days. In the event that a contract award by the OWNER is delayed beyond the 120-day period, such award shall be conditioned upon the proposer's acceptance.
The OWNER expects the successful proposer to solicit multiple bids from subcontractors and prepare a final bid after the project has been awarded that will be used to create a final Guaranteed Maximum Price (GMP) and construction contract.
Financial Information: Provide a statement of the proposer’s financial condition relative to the performance of this Project, specifically addressing ability to finance and maintain cash flow during the Project. Include an audited financial statement prepared by a certified public accountant, consisting of balance sheet, income statement, applicable notes and disclosures, and statement of changes in financial position, of the proposer’s firm covering the past three (3) fiscal years (or since commencement of operations, if less than three years). The most recent year’s financial statements must include either an Auditor's Report Letter or an Accountant's Review Letter.
Statement of Insurance: The Proposer must provide the minimum insurance coverage levels as show below and give evidence of same with copies of certificate(s) of insurance or letter(s) of intent to provide insurance from competent provider(s) doing business in the State of Colorado with an “A” rating as shown in the most recent edition of “Best’s Insurance Reports.”
o Worker's Compensation insurance to cover obligations imposed by applicable laws for any employee of Proposer or a subcontractor or sub-consultant engaged in the performance of work under this Agreement. Evidence of qualified self-insured status may be substituted for the Workmen's Compensation requirements of this Paragraph.
o General Liability insurance with minimum combined single limits of $1,000,000. The policy shall be applicable to all premises and operations. The policy shall include coverage for bodily injury, broad form property damage (including completed operations), personal injury (including coverage for contractual and employees' acts), blanket contractual, products, and completed operations. The policy shall contain a severability of interests provision.
o Comprehensive Automobile Liability insurance with minimum combined single limits for bodily injury and property damage of not less than $1,000,000 each occurrence and $1,000,000 aggregate with respect to each of Consultant's owned, hired or non-owned vehicles assigned to or used in performance of this Agreement. The policy shall contain a severability of interests provisions.
Qualifications and Requirements:
1. The General Contractor must be licensed to operate within the Town of Breckenridge, Summit County and the State of Colorado prior to proceeding with any work.
2. The firm must have the ability to provide payment, performance and maintenance bonds in an amount not less than the contract amount established in the construction contract as required by state statute.
3. The successful candidate shall demonstrate in the proposal relevant qualified experience as a CM/GC with the construction, expansion or remodel of commercial building structures
Attachment B: Acknowledgment of Receipt of RFP Packet, and Addenda: This form must be completed and signed by the Proposer, and attached to the proposal.
In the event the proposer intends to borrow any funds to finance any portion of the work pertaining to this Project, a letter of intent from the bank or other lending agency must be attached, indicating the minimum amount which will be loaned and the applicable percentage rate of interest to be charged. The letter of intent may contain the qualification that the loan will only be consummated upon award of a contract by the OWNER.
Financial information submitted to establish the financial capability, price proposal, overhead rates, and other aspects of the proposer’s fiscal condition shall be handled as confidential data and utilized on a "need-to-know" basis for proposal evaluation. The OWNER shall make all reasonable efforts to avoid disclosure to parties unrelated to the proposal evaluation process.
Any proposal not submitted in this format shall be deemed to be non-responsive and shall not be considered further by the OWNER. The signer of the proposal must declare that the only person(s), company or parties interested in the contract as principals are named herein; that it is, in all respects, fair and in good faith without collusion or fraud; and that the signer of the proposal has the authority to bind the principal offeror.
4. Selection Process
Each responsive proposal received by the OWNER shall be evaluated in a consistent manner as described in this subsection. A responsive proposal is one, which complies with all material aspects of the solicitation, both as to the method and timeliness of submission, and as to the substance of any resulting contract. Prospective Proposers are advised to submit all required forms, attachments, insurance certificates, and other information as requested in the RFP. The OWNER shall identify up to three (3) proposers who are considered to be best qualified to perform the work required by the
OWNER.
OWNER will review all responsive proposals. The proposals will be evaluated based on completeness, experience of contractor at this type of work, personnel proposed to work on the job, fee price and structure, the costs of general conditions, and local preference.
At the OWNER’s option, the best qualified firms may be invited to participate in oral interviews with for the purpose of clarifying and confirming offerings and assertions made in the proposals.
The OWNER reserves the right to delay making an award as necessary to permit proper study and analysis of all proposals received, to split award on proposals, to reject any or all proposals received, and to make a pre-award survey to determine the capability of any or all proposers. The OWNER reserves the right to reject any or all proposals if it believes there is a sound documented business reason for doing so, and to negotiate matters of Contractor performance, project schedule and other issues not directly related to the proposal price submitted prior to awarding a contract.
The OWNER further reserves the right to cancel the procurement process at any time during the evaluation process if it appears that the proposals received are not suitable for any reason whatsoever.
5. Inquiries
Any and all proposers may make inquiries in writing to OWNER at any time prior to Thursday February 29, 2024 5:00 p.m. Any written question of a proposer regarding the meaning or interpretation of the RFP, work scope, etc., must be submitted to the OWNER prior to the above-specified date. All clarifications given to any prospective proposer shall be similarly furnished to all prospective proposers in summary form as an addendum to this RFP if the lack of such information could reasonably be considered prejudicial towards uninformed proposers. No technical assistance shall be given by the OWNER to any proposer in preparation of its proposal.
Written inquiries shall only be directed to:
Melanie Leas Town of Breckenridge
Housing Division melaniel@townofbreckenridge.com
PO Box 168 Breckenridge, CO 80424
The OWNER will coordinate with the Architect/Engineering teams to answer all questions and shall provide a copy of its written response to any inquiries received to all proposers made known to the OWNER. Proposers, contractors and subcontractors SHALL NOT contact any member of the Architect/Engineering teams during the RFP process.
6. Addenda
Any or all changes, additions, or clarifications in connection with this RFP shall be issued by the OWNER in the form of written addenda. Each Proposer must sign the “Acknowledgment of Receipt of RFP Addenda” form (Attachment B) and submit the executed form with its proposal.
Oral comments, responses and/or representations shall not be binding upon the OWNER.
7. Consideration of Proposals
The OWNER reserves all rights to investigate the qualifications of any and all individuals and firms under consideration, to perform a financial audit of one or more firms, to confirm any part of the information furnished in a proposal, and to require further evidence of managerial, financial or professional capabilities which are considered necessary for the successful performance of work described in this RFP. The OWNER reserves the right to reject any or all proposals and to waive informalities and minor irregularities in proposals received.
8. Disclosure of Proposal Contents
All proposals and supporting documents, except such information that discloses proprietary or financial information submitted in response to qualification statements, becomes public information held in custody of the OWNER after the proposal submittal date given in this RFP.
The OWNER assumes no liability for the use or disclosure of technical or cost data submitted by any Proposer.
Nevertheless, if a proposal contains information that the respondent does not want disclosed to the public, or used for any purpose other than the evaluation of this offer, all such information must be indicated with the following or similar statement:
"The information contained on pages ________ shall not be duplicated, used in whole or in part for any purpose other than to evaluate the proposal provided; that if a contract is awarded to this firm as a result of the submission of such information, the OWNER shall have the right to duplicate, use or disclose this information to the extent provided in the contract. This restriction does not limit the OWNER’s right to use the information contained herein if obtained from another source."
All such nondisclosure items specified in the proposal shall be subject to disclosure as provided in Part 2 of Article 72 of Title 24, C.R.S. ("The Colorado Public Records Act") or as otherwise provided by law.
9. Original Proposal
The successful proposal must be an original work product of the submitting individual, firm or team. Copying, paraphrasing, or otherwise using significant portions of the work product of another organization when presenting a proposal to the OWNER shall not be permitted. Failure to adhere to this instruction may result in the rejection of the proposal.
10. Investigation of Conditions
All proposers are encouraged to review this RFP carefully and to investigate all conditions involved in the execution of work. The selected firm shall not be allowed additional compensation for items on which it has failed to inform itself prior to the opening of proposals.
11. Withdrawal of Proposal
Prior to the due date indicated in the RFP packet, any proposer may withdraw its proposal submitted to the OWNER by written, email, or fax notification, or in person by a firm principal or authorized representative, provided his/her identity is made known and a receipt is signed for the return of the proposal. Regardless of form, such notice must be in written form and received by the OWNER prior to the hour and date specified for receipt of proposals. After proposals are opened as prescribed herein, no proposal may be withdrawn for a period of one hundred and twenty (120) calendar days. Negligence on the part of a proposer in preparing its proposal shall not confer a right of withdrawal after the date proposals are received by the OWNER.
12. Single Proposal Response
In the event that only one (1) proposal is received in response to this RFP, the OWNER may require assistance from the single responsive and responsible proposer in the preparation of a proposal price analysis in order to determine whether the single proposal received by the OWNER is fair and reasonable.
13. Conflicts and Inconsistencies
In the event of a conflict or inconsistency between any of the RFP and attachments, including drawings, specifications, the OWNER shall resolve such conflict or inconsistency and provide written notice of the single interpretation to all known proposers by written addendum.
14. Contract Award
The OWNER maintains the right, but shall be under no obligation, to award a contract to the responsive and responsible Proposer whose offer is deemed by the OWNER to be most advantageous to the OWNER as determined by capability, qualifications and other factors set forth herein. Proposers are hereby advised that contract award is subject to approval by the OWNER Council.
15. News Releases
Written approval by the OWNER is required prior to any public disclosure regarding this RFP or any subsequent awards.
16. Cost of Proposal Preparation
The OWNER shall not be liable for any costs or expenses incurred for preparation of proposals submitted in response to this RFP or for any other cost incurred prior to issuance of a formal Notice to Proceed. Proposers shall not include such expenses as part of the price proposed. The OWNER shall be held harmless and free from any and all liability, claims or expenses whatsoever incurred by, or on behalf of, any person or organization responding to this RFP.
SECTION II: SCOPE OF SERVICES
1. Background
Timberline Learning Center (TLC) was built in 2008 by the Town of Breckenridge to care for children from six weeks to six years old. The current 3,300 square foot building has a capacity of 68 children across six classrooms and a multipurpose space for indoor activities.
As of June 2022, Early Childhood Options reports that Breckenridge has 520 unique children currently on a waitlist for care with the highest need being infant and toddler care. Given the significant demand for additional childcare slots, the Town is committed to expanding TLC to provide an additional space to add more students.
2. Summary of Work Required
The Town of Breckenridge desires to contract with a reputable experienced contractor to perform pre-construction services and construction management of the project. Initial plans for the project are attached.
Phase One: Phase One is Pre-Construction services. Pre-construction services include, but are not limited to:
1. Attending Design Team meetings with the Architect and Owner.
2. Providing detailed cost estimates on Construction Documents for buildings and site work.
3. Providing cost analysis of design decisions and value engineering options
4. Providing input on pre-ordering of long lead construction items.
5. Administration of the subcontract bid process for the civil site work and vertical construction.
In an effort to make the construction phase as efficient as possible, the selected Contractor will be expected to be actively engaged in the design process and will be expected to make recommendations and suggest alternatives as appropriate.
The contractor will provide a cost evaluation of constructing the buildings individually over time versus constructing all at once. This information will include an opinion from the contractor on the savings generated by constructing all buildings at once versus individually.
The civil site work project will include utility, drainage, grading, landscaping, and hardscape (sidewalk, pavers, flagstone) improvements.
Phase Two: Phase Two is the construction management of the project. This Phase will be the construction of the project as designed and estimated in Phase One. If this phase moves forward the Town and Contractor will enter into a construction contract with a guaranteed maximum price. The Town may determine that it is not in its best interest to continue with Phase Two.
The Town reserves the right to not enter into a contract with the contractor.
SECTION III: SUBMITTAL FORMS
PROPOSAL SUBMITTAL CHECKLIST
This form must be completed and returned with the proposal submittal.
Attachment
Description
Proposer’s
Initials
Town’s
Initials Cover Letter (signed) Organizational Information
References Project Management and Personnel Project Approach Project Schedule Fee Schedule
Financial Information Statement of Insurance Qualifications and Requirements
B Acknowledgment of Receipt of RFP Packet and
Addenda
AIA Doc. A305-1986 – Contractor’s Qualification
Statement
Signature of Proposer: _________________________________________________
Date: __________________________________________ https://biznet.ct.gov/SCP_Documents/Bids/46754/A305-1986_-_Final.pdf https://biznet.ct.gov/SCP_Documents/Bids/46754/A305-1986_-_Final.pdf
ATTACHMENT A
MINIMUM REQUIRED GENERAL CONDITIONS
Superintendent Assist. Superintendent Project Manager Clerk of the Works Assist Project Manager/Field Housing & Subsistence Superintendent Cell Phone Assist Superintendent Cell Phone Temp radios Superintendent Vehicle Superintendent Fuel Assist Superintendent fuel PM cell phone PM vehicle and fuel Home office travel costs Trailer Storage Dumpster Misc first aid Safety inspections Drinking Water per OSHA Toilets Blueprints/copies O&Ms and as-constructed drawing Field Office Supplies Field Office equipment Permits (Town will waive or reimburse permit fees) Builder's Risk Insurance & Bonding Material testing Photographs UPS, Fed-ex, postage, etc.
Snow Removal Temporary Utilities including power, phone, water, gas etc.
Temporary Heat
ATTACHMENT B
ACKNOWLEDGMENT OF RECEIPT OF RFP PACKET AND ADDENDA
The undersigned hereby acknowledges receipt of the Town of Breckenridge Request for Proposals (RFP) packet, and the following addenda issued during the procurement process.
Addendum #1: ______________________________________ dated ___________
Addendum #2: ______________________________________ dated ___________
Addendum #3: ______________________________________ dated __________
Failure to acknowledge receipt of the proposal packet below, and all addenda may cause the proposal to be considered non-responsive to this solicitation.
Name of Proposer: _______________________________
Signature of Proposer:_______________________________
Date: _______________________________
PROJECT NUMBER:01/30/2024
TIMBERLINE LEARNING
CENTER
820175-01
BID PACKAGE
50% CONSTRUCTION DOCUMENTS
170 Valley Brook St Breckenridge, CO 80424
© 2021 Eppstein Uhen Architects, Inc.
A/C air conditioning
A/E Architect/Engineer
ACT acoustical ceiling tile
ADDL additional
ADDM addendum
ADJ adjustable
AFC above finished counter
AFF above finished floor
AFG above finished grade AFS above finished slab
ALT alternate
ALUM aluminum
APPD approved
APT apartment AP acoustical panel
ASC above suspended ceiling
BB baseboard
BLDG building
BLT borrowed lite
BLW below
BPL base plate BO bottom of
BOS bottom of steel
CB catch basin, construction bulletin
CF/CI contractor furnished, contractor installed
CF/OI contractor furnished, owner installed CF/VI contractor furnished, vendor installed
CG corner guard
CIP cast-in-place
CNTR counter CL centerline
CLG ceiling
A
B
C
CLR clear
CM construction management CM construction manager
CMU concrete masonry unit
CO cleanout
COL column
CONC concrete
CORR corridor CPT carpet
CSWK casework
CT ceramic tile
CW cold water
CTB ceramic tile base
DEMO demolition
DEPT department
DF drinking fountain
DIA diameter DP decorative panel
DR door
DR FR door frame
DTL detail
DS downspout DW dishwasher
DWG drawing
E east
EIFS exterior insulation & finish system
EL elevation
EJ expansion joint
ELEC electric
ELEC electrical ELEV elevator
EP epoxy
EPS expanded polystyrene board
EQ equal
ETR existing to remain EXIST existing
EXT exterior
F
G
H
F female
F filler
FA fire alarm FA fluid-applied
FAB fabric
FC file cabinet
FD floor drain
FE fire extinguisher FEC fire extinguisher cabinet
FHC fire hose cabinet
FLR floor
FM factory mutual FM floor mat
FO finished opening
FP fire protection
FP fireproof
FPL fireplace
FRP fiberglass reinforced plastic
FRT fire retardant treated
FTG footing
GA gauge
GALV galvanized
GB grab bar
GC general contractor
GL glass GLU LAM glue laminated wood
GR grade, grading
GT grout
GYP BD gypsum
HB hose bibb
HC hollow core
HM hollow metal HORIZ horizontal
HSKP housekeeping
HGT height
HVAC heating, ventilating
& air conditioning HW hot water
HWY highway
T&M time & materials
TEMP temperature
TEMP temporary TER terrazzo
TERB terrazzo base
TFF top of finished floor
TKBD tackboard
TO top of
TOB top of beam TOC top of concrete
TOJ top of joist
TOPO topography
TOS top of slab
TOS top of steel TYP typical
UNO unless noted otherwise
VERT vertical
VF/CI vendor furnished, contractor installed
VF/OI vendor furnished, owner installed
VF/VI vendor furnished, vendor installed
VNR veneer
VIF verify in field
W west
W/ with
W/O without
WC water closet WC wall covering
WD wood
WDB wood base
WDV wood veneer
WH water heater WP wall protection
WP work point
WT window treatment
XPS extruded polystyrene board
ID inside diameter
INSUL insulation
INT interior
JS janitor sink
LAM laminate LAV lavatory
LL live load
MAX maximum MC modular carpet tile
MECH mechanical
MFR manufacturer
MICRO microwave
MIN minimum MIN minute
MISC miscellaneous
MJ movement joint
MO masonry opening
MS mop sink MTL metal
N north
NA not applicable NIC not in contract
NO number
NM nominal
NS no scale
NTS not to scale
OC on center
OD outside diameter
OF/CI owner furnished, contractor installed OF/OI owner furnished, owner installed
OF/VI owner furnished, vendor installed
OH DR overhead door OPH opposite hand
OPNG opening
PJ panel joint
PLAM plastic laminate
PLYWD plywood PNL panel
PREFAB prefabricated
PREFIN prefinished
PSI pounds per square inch PT paint
PTN partition
QT quarry tile QTB quarry tile base
QTZ quartz
RB resilient base
RCP reflected ceiling plan RD roof drain
REBAR reinforcing steel bars
REC recess
REF reference
REF refrigerator RF resilient flooring
REV revision
RFS room finish schedule
RO rough opening
S south
SAN sanitary
SC sealed concrete
SC solid core SCHED schedule
SCHED scheduled
SF square foot
SIM sim
SS solid surface SST stainless steel
ST stain
ST stair
STL steel
STN stone STNB stone base
STRUCT structure
C
D
E
I
M
N
J
L
O
Q
R
S
P T
W
X
U
V
TRUE
N
PLAN
N
B
000-00
NAME
TYPE
HEIGHT
XXX
XX
FLOOR
BASE
WALL
REMARKS
PARTITION TYPE
DOOR
KEYNOTE
FURNITURE
EQUIPMENT
WINDOW
XX
CEILING
CASEWORK
FINISH PLAN
A
B
A
ELEVATION
DATUM
VIEW NUMBER
VIEW NAME
VIEW SCALE
DEMOLITION
GRID AND GRID IDENTIFICATION
1 21 2
A000
A000
SIM
A000
SIM
BUILDING
SECTIONS
OTHER
SECTIONS
CONSTRUCTION PHASES
ELEVATIONS
ROOM
DETAILS
TITLE
1/2" = 1'-0"
DIMENSION REFERENCES
EXISTING NEW
NEW EXISTING
A1
SIM
TAGSCALLOUTS GRAPHICS
NORTH ARROW
TO OBJECT CENTER TO OBJECT FACE
OR OTHER GEOMETRY
EQ EQ EQ 5'-0" 4'-0"
W" x H" x D"
A000
Level
0'-0"
A000-000A
A2
A
A4
A000A
A2
A
A4
These documents reflect progress and intent and may be subject to change, including additional detail. These are not final construction documents and shall not be used for final bidding or construction-related purposes.
PROGRESS DOCUMENTS
NOT FOR CONSTRUCTION
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
m i l w a u k e e 333 East Chicago Street Milwaukee, Wisconsin 53202 414.271.5350
309 West Johnson Street, Suite 202 Madison, Wisconsin 53703 608.442.5350 m a d i s o n
1899 Wynkoop Street, Suite 700 Denver, Colorado 80202 303.595.4500 d e n v e r
PROJECT TEAM
SYMBOL LEGEND
VICINITY MAP
ABBREVIATIONS SHEET INDEX
TIMBERLINE
LEARNING CENTER
INDEX
G000
820175-01
JC
170 Valley Brook St Breckenridge, CO 80424
© 2021 Eppstein Uhen Architects, Inc.
GENERAL
G000 INDEX
G101 1ST FLR LIFE SAFETY PLAN
CIVIL
C1.0 DEMO PLAN
C2.0 GRADING PLAN
STRUCTURAL
S000 GENERAL NOTES
S001 ABBREVIATION, SYMBOLS KEY, & 3D SCHEMATIC VIEW
S002 IBC STATMENT OF SPECIAL INSPECTION
S101 FOUNDATION, & ROOF FRAMING PLAN
S301 FULL HT SECTIONS
S502 TYPICAL WOOD & STEEL DETAILS
S510 DETAILS
ARCHITECTURAL DEMOLITION
AD101 1ST FLR DEMOLITION PLAN
ARCHITECTURAL
A000 BUILDING SYSTEMS & NOTES
A010 ADA REQUIREMENTS
A100 MAIN FLOOR PLAN
A110 ROOF PLAN
A120 FINISH FLOOR PLAN
A200 EXTERIOR ELEVATIONS
A500 WALL SECTION
A510 BUILDING SECTIONS AND EXTERIOR SECTION DETAILS
A600 DOOR AND FRAME SCHEDULE
PLUMBING
P000 PLUMBING COVER SHEET-LEGEND & GENERAL NOTES
FP101 OVERALL FIRE PROTECTION PLAN
P101 PLUMBING PLAN
MECHANICAL
M100 CRAWL SPACE HVAC PLAN
M101 MAIN FLOOR HVAC PLAN
M700 HVAC SCHEDULES AND DETAILS
MD100 CRAWL SPACE HVAC DEMOLITION PLAN
MD101 MAIN FLOOR DEMOLITION PLAN
EMAIL ADDRESS:
DIRECT PHONE:
PROJECT CONTACT:
ARCHITECTURAL
EPPSTEIN UHEN ARCHITECTS, INC.
1899 Wynkoop Street, Suite 700 Denver, CO 80202
PHONE: (303) 595-4500
www.eua.com
Sara Schesser , Project Architect 303.256.1139 saras@eua.com
EMAIL ADDRESS:
DIRECT PHONE:
PROJECT CONTACT:
ELECTRICAL ENGINEERING
ACKERMAN ENGINEERING, INC.
3000 Youngfield St, Suite 264 Wheat Ridge, CO 80215
PHONE: 303-278-7297
www.aeiconsulting.com
Tanner Ackerman 303-278-7297 tackerman@aeiconsulting.com
EMAIL ADDRESS:
DIRECT PHONE:
PROJECT CONTACT:
MECHANICAL AND PLUMBING ENGINEER
THE BALLARD GROUP
2525 S Wadsworth Blvd STE 200 Lakewood, CO 80227
PHONE: 303-988-4514
www.theballardgroup.com
Bert Baiotto , Principal 303-867-6842
BBaiotto@theballardgroup.com
EMAIL ADDRESS:
DIRECT PHONE:
PROJECT CONTACT:
STRUCTURAL ENGINEER
JVA CONSULTING ENGINEERS
1675 Larimer Street #550 Denver, CO 80202
PHONE: 303-444-1951
www.jvajva.com
Amber Lebsock , S. Project Eng.
303-565-4975 alebsock@jvajva.com
EMAIL ADDRESS:
DIRECT PHONE:
PROJECT CONTACT:
CIVIL ENGINEER
ALPINE ENGINEERING INC.
34510 Highway 6 Unit A-9 Edwards, CO 81632
PHONE: 970-926-3373
www.alpineciv.com
Matt Wadey , Principal 970-926-3373 wadey@alpinecivil.com
EMAIL ADDRESS:
DIRECT PHONE:
PROJECT CONTACT:
OWNER
TIMBERLINE LEARNING CENTER
170 Valley Brook St Breckenridge, CO 80424
PHONE: 970-453-9656
www.website.com
Melanie Leas , Housing PM 970-453-3161 melaniel@townofbreckenridge.com
COPYRIGHT - GOOGLE MAPS
PROJECT SITE
DATE DESCRIPTION
UP
LIFE SAFETY GENERAL NOTES
1. WHEN A WALL HAS MORE THAN ONE CLASSIFICATION, THE MOST RESTRICTIVE REQUIREMENTS FOR EACH
CLASSIFICATION SHALL APPLY.
2. FOR NEW CONSTRUCTION, PERIMETER SMOKE-SEALS MAY BE REQUIRED AT FIRE-RATED DOORS IN
CERTAIN OCCUPANCIES.
LIFE SAFETY DRAWING NOTES APPLICABLE TO EXISTING CONDITIONS
EXISTING CONDITIONS INDICATED BY THESE LIFE SAFETY PLANS ARE BASED ON INFORMATION PROVIDED AND AN ANALYSIS OF APPLICABLE CODES. IF EXISTING FIELD CONDITIONS ARE DISCOVERED TO BE
DIFFERENT FROM WHAT IS INDICATED ON THESE PLANS, CONTACT THE ARCHITECT.
WITHIN LIMITS OF NEW CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE
FOLLOWING AND PATCH DEFICIENCIES (IF ANY ARE DISCOVERED) OF EXISTING ASSEMBLIES.
• CONTINUITY OF SPRAYED ON FIRE PROTECTION
• CONTINUITY OF FIRE RATINGS AND SMOKE-TIGHTNESS REQUIREMENTS OF FLOOR ASSEMBLIES
• WALL FIRE RATINGS AND SMOKE-TIGHTNESS REQUIREMENTS AS INDICATED BY THESE LIFE SAFETY PLANS
• FIRE STOPPING OF THROUGH PENETRATIONS
• FIRE STOPPING OF PERIMETER JOINTS
A.5A B C D E F G H J K L
570 SF
17 OCC
CLASSROOM
E
654 SF
19 OCC
CLASSROOM
E
566 SF
17 OCC
CLASSROOM
E
640 SF
19 OCC
CLASSROOM
E
509 SF
15 OCC
CLASSROOM
E
556 SF
16 OCC
CLASSROOM
E
662 SF
19 OCC
CLASSROOM
E
604 SF
18 OCC
CLASSROOM
E
121 SF
1 OCC
OFFICE
B
146 SF
1 OCC
OFFICE
B
203 SF
2 OCC
OFFICE
B
226 SF
2 OCC
OFFICE
B
121 SF
1 OCC
KITCHEN
B
65 SF
1 OCC
STORAGE
S-1
14 SF
1 OCC
STORAGE
S-1
107 SF
1 OCC
STORAGE
S-1
267 SF
1 OCC
MECH
S-1
39 SF
1 OCC
UTILITY
S-1
143 SF
1 OCC
UTILITY
S-1
42 SF
1 OCC
STORAGE
S-1
43 SF
1 OCC
STORAGE
S-1
36 SF
1 OCC
STORAGE
S-1
45 SF
1 OCC
STORAGE
S-1
68"
32"
32"
32"
32"
THIS EXIT NOT
INCLUDED IN
EGRESS
CALCULATIONS
EXIT DISTANCE = 71'-1"
GENERAL BUILDING HEIGHT AND AREA
Type of Construction
V-B, fully sprinklered
Actual Allowable Building Height/Stories 30' - 6" / 1 TBU
Building Area Allowed: TBU
Actual: TBU
MEANS OF EGRESS
Egress width factor for completely sprinklered areas Corridors and Doors .2 Stairs .3
Exit Width 260 occupants x .2 = 52" (420" provided)
MAXIMUM EXIT ACCESS TRAVEL DISTANCE
Type I-4 Occupancy with Sprinkler System: 200'
WORK AREAS INCLUSIVE OF ENTIRE BUILDING - 2018 IEBC
NEW CONSTRUCTION
ALTERATION LEVEL 1
ALTERATION LEVEL 2
EXISTING NO WORK
All Level 1 alterations to comply with Chapters 3 and 7 of the
2018 IEBC
All Level 2 alterations to comply with Chapters 3, 7, and 8 of the 2018 IEBC
New Construction to comply with the 2018 IBC, 2018 IECC
757 SF 9%
0 SF 0%
939 SF 11%
7075 SF 80%
FIRE RESISTIVE LEGEND
SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH EXTINGUISHER
FIRE EXTINGUISHERS
FE-1
MEANS OF EGRESS
X"
X"
EXIT DISCHARGE
X = CLEAR WIDTH OF OPENING IN INCHES
FROM ROOM OR LEVEL
X = CLEAR WIDTH OF OPENING IN INCHES
These documents reflect progress and intent and may be subject to change, including additional detail. These are not final construction documents and shall not be used for final bidding or construction-related purposes.
PROGRESS DOCUMENTS
NOT FOR CONSTRUCTION
PROJECT MANAGER
PROJECT NUMBER
KEY PLAN
SHEET INFORMATION
PROJECT INFORMATION
ISSUANCE AND REVISIONS
E
D
C
B
A
21 654 7
321 654 7
E
D
C
B
A m i l w a u k e e 333 East Chicago Street Milwaukee, Wisconsin 53202 414.271.5350
309 West Johnson Street, Suite 202 Madison, Wisconsin 53703 608.442.5350 m a d i s o n
1899 Wynkoop Street, Suite 700 Denver, Colorado 80202 303.595.4500 d e n v e r
TIMBERLINE
LEARNING CENTER
1ST FLR LIFE
SAFETY PLAN
G101
820175-01
JC
170 Valley Brook St Breckenridge, CO 80424
© 2021 Eppstein Uhen Architects, Inc.
ONE CLASSROOM ADDITION, RENOVATION OF FORMER MULTIPURPOSE ROOM INTO ONE
CLASSROOM, STORAGE ROOMS, AND RESTROOM
PROJECT SUMMARY
OCCUPANT LOAD 260 OCCUPANTS
S-1 (STORAGE)
B (BUSINESS)
OCCUPANCY TYPE E (EDUCATIONAL)
ORIGINAL DATE OF CONSTRUCTION 2007
PROJECT GROSS AREA 757 SF NEW CONSTRUCTION + 939 SF RENOVATION
AREA = 20 % OF TOTAL BUILDING AREA
PROJECT TYPE ADDITION + LEVEL 2 ALTERATION; PER 2018 IEBC
PROJECT INFORMATION
FIRE PROTECTION SPRINKLERED
TOTAL BUILDING AREA 8,771 SF
NUMBER OF STORIES 1
ORIGINAL DATE OF CONSTRUCTION 2007
CONSTRUCTION TYPE V-B
GENERAL INFORMATION
2021 NFPA 170
2018 COLORADO FUEL GAS CODE
2018 COLORADO PLUMBING CODE
2017 ICC A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES
2023 NATIONAL ELECTRICAL CODE (NEC)
2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2021 INTERNATIONAL FIRE CODE (IFC)
2018 INTERNATIONAL MECHANICAL CODE (IMC)
2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
2018 INTERNATIONAL BUILDING CODE (IBC) WITH LOCAL AMENDMENTS
APPLICABLE BUILDING CODES
FIRE DEPARTMENT BRECKENRIDGE FIRE RESCUE
BUILDING DEPARTMENT STATE OF COLORADO - DIVISION OF FIRE
PREVENTION AND CONTROL
JURISDICTIONS
VALLEY BROOK CHILDCARE CENTER
OWNER
PROJECT DATA
N
1/8" = 1'-0" A1
LL OCCUPANCY CLASSIFICATION
Occupancy Classification Occupancy Space
Name Area Area per Occupant Gross or Net Occupant Total STORAGE 65.18 SF 300 Gross 1
STORAGE 14.18 SF 300 Gross 1
STORAGE 106.66 SF 300 Gross 1
MECH 267.14 SF 300 Gross 1
UTILITY 39.08 SF 300 Gross 1
UTILITY 143.11 SF 300 Gross 1
STORAGE 41.75 SF 300 Gross 1
STORAGE 42.56 SF 300 Gross 1
STORAGE 35.66 SF 300 Gross 1
STORAGE 45.14 SF 300 Gross 1
OFFICE 121.27 SF 150 Gross 1
OFFICE 145.52 SF 150 Gross 1
OFFICE 202.67 SF 150 Gross 2
OFFICE 226.5 SF 150 Gross 2
CLASSROOM 570.38 SF 35 Net 17
CLASSROOM 653.8 SF 35 Net 19
CLASSROOM 566.38 SF 35 Net 17
CLASSROOM 640.02 SF 35 Net 19
CLASSROOM 509.02 SF 35 Net 15
CLASSROOM 556.28 SF 35 Net 16
CLASSROOM 662.45 SF 35 Net 19
CLASSROOM 603.78 SF 35 Net 18
KITCHEN 121 SF 200 Gross 1
Grand total 157
DATE DESCRIPTION
Increase: 20
New Occupant Load: 260
Previous Occupant Load: 240
** IEBC, Section 809 Plumbing: 809.1 Minimum fixtures. Where the occupant load of the story is increased by more than 20 percent, plumbing fixtures for the story shall be provided in quantities specified in the International Plumbing Code based on the increased occupant load. The occupant load of building has been increased by 8.3%, therefore building does not need to come into compliance wit the current code.
Note:
9 9 2 1
PROVIDED **
WATER CLOSETS LAVATORIES
DRINKING
FOUNTAINS
SERVICE
SINK
REQUIRED TOTALS 11 11 3
SUBTOTALS 10.33 10.33 1.47
BUSINESS 7
1 per 25 for the first
50 and 1 per 50 for the remainder exceeding 50
1.00
1 per 40 for the first
80 and 1 per 80 for the remainder exceeding 80
1.00 1 per 100 0.07
INSTITUTIONAL -
CHILD DAY CARE
140 1 per 15 9.33 1 per 15 9.33 1 per 100 1.4
USE LOAD RATIO FIXTURES RATIO FIXTURES
SPACE WATER CLOSETS LAVATORIES DRINKING
FOUNTAIN
RATIO
DRINKING
FOUNTAINS
SERVICE
SINK
STRUCTURAL GENERAL NOTES
FOUNDATION DESIGN:
1. REFER TO SOILS REPORT NO. SU02352.000-125 BY CTL THOMPSON, DATED MAY 25, 2023.
2. GEOTECHNICAL ENGINEER SHALL VERIFY SOIL CONDITIONS AND TYPES DURING EXCAVATION AND PRIOR TO
PLACEMENT OF FORMWORK OR CONCRETE.
3. FROST DEPTH SHALL BE 3'-4" MINIMUM BELOW EXTERIOR GRADE.
FOOTINGS:
1. DESIGN OF FOOTINGS IS BASED ON
A. MAXIMUM ALLOWABLE BEARING PRESSURE 3000 PSF
B. MINIMUM DEAD LOAD PRESSURE NA.
2. BEAR ON THE NATURAL UNDISTURBED SOIL OR COMPACTED STRUCTURAL FILL. EXTERIOR FOOTINGS SHALL
BEAR BELOW FROST DEPTH.
EARTH RETAINING STRUCTURES:
1. EARTH EQUIVALENT FLUID LATERAL PRESSURE:
A. WALLS RESTRAINED AT TOP (AT REST) 50 PCF
B. CANTILEVERED WALLS (ACTIVE) 40 PCF
C. PASSIVE RESISTING 400 PCF
2. COEFFICIENT OF SLIDING FRICTION 0.45
REINFORCED CONCRETE:
1. DESIGN IS BASED ON ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE."
2. CONCRETE WORK SHALL CONFORM TO ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE."
3. STRUCTURAL CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES:
4. CONCRETE MIX TABLE NOTES:
A. CONCRETE MIX SUBMITTAL SHALL INCLUDE A SINGLE PAGE LIST OF MIXES, IN TABULAR FORMAT, WITH KEY
MIX REQUIREMENTS.
B. SLUMP VALUES INDICATED ARE SUGGESTED BASED ON USE AND TYPICAL PLACEMENT METHODS.
CONTRACTOR MAY ADJUST SLUMP AS NECESSARY FOR FIELD CONDITIONS AND INSTALLATION METHOD
USED PROVIDED REMAINING REQUIREMENTS ARE MET.
C. AIR CONTENT:
a. N/P: AIR ENTRAINING ADMIXTURES NOT PERMITTED, ENTRAPPED AIR ONLY
b. N/A: NOT APPLICABLE, NO STRUCTURAL AIR CONTENT REQUIREMENTS
D. SHRINKAGE STRAIN: MIXES NOTED AS "SHRINKAGE XX%" SHALL BE LIMITED TO A MAXIMUM DRYING SHRINKAGE ( 0.05% UNLESS NOTED OTHERWISE) AT 28 DAYS (500 MICROSTRAIN) AS MEASURED BY ASTM
C157. SHRINKAGE TEST RESULTS TO BE INCLUDED WITH MIX DESIGN SUBMITTAL.
E. GENERAL CONTRACTOR TO COORDINATE CONCRETE MOISTURE LEVEL AND ANTICIPATED MOISTURE
MITIGATION PROCEDURES WITH CONCRETE SUPPLIER/MIX DESIGNER AND OTHER AFFECTED
SUBCONTRACTORS (INCLUDING BUT NOT LIMITED TO FLOORING) TO ADDRESS ALL POTENTIAL SCHEDULE
AND INSTALLATION CONFLICTS.
5. DETAILING, FABRICATION, AND PLACEMENT OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI 315
"DETAILS AND DETAILING OF CONCRETE REINFORCEMENT."
6. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064.
7. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60, EXCEPT BARS SHOWN TO BE FIELD-BENT SHALL
BE ASTM A706, GRADE 60.
8. EPOXY COATED REINFORCING BARS SHALL CONFORM TO ASTM A775 (STRAIGHT BARS) AND ASTM A934 (PRE-
FABRICATED BARS).
9. ZINC COATED (GALVANIZED) REINFORCING BARS SHALL CONFORM TO ASTM A767.
10. BARS TO BE WELDED SHALL CONFORM TO ASTM A706.
11. UNLESS NOTED OTHERWISE ON THE STRUCTURAL DRAWINGS, LAP BARS PER THE CONCRETE LAP SPLICE
SCHEDULE.
12. AT CORNERS AND INTERSECTIONS, MAKE HORIZONTAL BARS CONTINUOUS OR PROVIDE MATCHING CORNER
BARS FOR EACH LAYER OF REINFORCEMENT.
13. TRIM OPENINGS IN WALLS AND SLABS WITH (2) #5 FOR EACH LAYER OF REINFORCEMENT, FULLY DEVELOPED BY
EXTENSION OR HOOK.
14. IN CONTINUOUS MEMBERS, SPLICE TOP BARS AT MID-SPAN AND SPLICE BOTTOM BARS OVER SUPPORTS.
15. FORM INTERMITTENT SHEAR KEYS AT ALL CONSTRUCTION JOINTS AND AS SHOWN ON THE STRUCTURAL
DRAWINGS.
16. EXCEPT AS NOTED ON THE DRAWINGS, CONCRETE PROTECTION FOR REINFORCEMENT IN CAST-IN-PLACE
CONCRETE SHALL BE AS FOLLOWS:
A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"
B. EXPOSED TO EARTH OR WEATHER:
1. #6 THROUGH #18 BARS 2"
2. #5 BAR, W31 OR D31 WIRE, AND SMALLER 1-1/2"
C. NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
1. SLABS, WALLS, JOISTS: #11 BARS AND SMALLER 3/4"
2. BEAMS AND COLUMNS:
a. PRIMARY REINFORCEMENT 1-1/2"
b. STIRRUPS, TIES, SPIRALS 1-1/2"
17. FIBER ADMIXTURE SHALL BE 100% VIRGIN POLYPROPYLENE, FIBRILLATED FIBERS, TYPE III 4.1.3, PERFORMANCE
LEVEL ONE, PER ASTM C1116.
18. ANCHOR BOLTS AND RODS FOR BEAM AND COLUMN-BEARING PLATES SHALL BE PLACED WITH SETTING
TEMPLATES.
POST-INSTALLED ANCHORS
1. ALL CAST-IN-PLACE ANCHORS DESIGNED IN ACCORDANCE WITH ACI 318.
2. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE
CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER-OF-RECORD PRIOR TO INSTALLING POST-
INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS.
3. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING REBAR.
EXISTING REINFORCING BARS SHALL NOT BE CUT UNLESS APPROVED BY THE EOR.
4. ALL ANCHORS MUST BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER’S PRINTED INSTALLATION INFORMATION (MPII) IN CONJUNCTION WITH EDGE DISTANCE, SPACING, AND EMBEDMENT DEPTH AS INDICATED ON THE DRAWINGS. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MPII.
5. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER-OF-RECORD ALONG WITH CALCULATIONS THAT ARE PREPARED & SEALED BY A REGISTERED PROFESSIONAL ENGINEER; REGISTRATION MUST BE IN THE STATE IN WHICH THE PROJECT IS LOCATED. THE CALCULATIONS SHALL DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE AUTHORITY HAVING
JURISDICTION.
6. THE CONTRACTOR SHALL ARRANGE FOR A MANUFACTURER’S FIELD REPRESENTATIVE TO PROVIDE INSTALLATION TRAINING FOR ALL PRODUCTS TO BE USED, PRIOR TO THE ANCHOR INSTALLATION. A RECORD OF TRAINING SHALL BE KEPT ON SITE AND MADE AVAILABLE TO THE EOR/ SPECIAL INSPECTOR AS REQUESTED.
7. ADHESIVE ANCHORS INSTALLED IN HORIZONTAL TO VERTICALLY OVERHEAD ORIENTATION THAT SUPPORT SUSTAINED TENSION LOADS SHALL BE DONE BY A CERTIFIED ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI/CRSI (ACI 318-11 D 9.2.2, ACI 318-14 17.8.2.2). PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED TO
THE EOR FOR APPROVAL PRIOR TO COMMENCEMENT OF INSTALLATION.
8. ADHESIVE ANCHORS MUST BE INSTALLED IN CONCRETE AGED A MINIMUM OF 21 DAYS (ACI 318-11 D 2.2, ACI 318-14 17.1.2)
9. ALL POST-INSTALLED ANCHORS SHALL BE INSTALLED IN DRY HOLES THAT HAVE BEEN DRILLED, CLEANED, AND PREPARED IN STRICT ACCORDANCE WITH THE MANUFACTURER’S PRINTED INSTALLATION INFORMATION AND
THE RESPECTIVE ICC-ES EVALUATION REPORTS.
10. PROVIDE SPECIAL INSPECTION FOR ALL MECHANICAL AND ADHESIVE ANCHORS PER THE APPLICABLE BUILDING
CODE AND PER THE CURRENT ICC-ES REPORT (IBC TABLE 1705.3 NOTE B).
STRUCTURAL STEEL:
1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE
"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" (AISC 360) AND THE "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" (AISC 303) BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC).
2. STRUCTURAL STEEL WIDE FLANGE BEAMS AND WTS SHALL CONFORM TO ASTM A992, 50 KSI YIELD.
3. ROLLED STEEL FLOOR PLATES SHALL CONFORM TO ASTM A786, COMMERCIAL GRADE.
4. OTHER ROLLED SHAPES, INCLUDING PLATES, CHANNELS, AND ANGLES SHALL CONFORM TO ASTM A36, 36 KSI
YIELD.
5. HOLLOW STRUCTURAL SECTION (HSS) RECTANGULAR SHAPES SHALL CONFORM TO ASTM A500, GRADE C, 50 KSI
YIELD.
6. HSS ROUND SHAPES SHALL CONFORM TO ASTM A500, GRADE C, 46 KSI YIELD.
7. PIPE SHAPES SHALL CONFORM TO ASTM A53, GRADE B, 35 KSI YIELD.
8. EXCEPT AS NOTED, FRAMED BEAM CONNECTIONS SHALL BE BEARING-TYPE WITH 3/4" DIAMETER, SNUG TIGHT, ASTM F3125 BOLTS, DETAILED IN CONFORMANCE WITH THE STRUCTURAL DRAWINGS AND THE "STEEL CONSTRUCTION MANUAL" BY THE AISC. INSTALL BOLTS IN ACCORDANCE WITH AISC'S "SPECIFICATION FOR
STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS".
9. ALL BEAMS SHALL HAVE FULL DEPTH WEB STIFFENERS EACH SIDE OF WEBS ABOVE AND BELOW COLUMNS.
10. ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE (36, 55 WITH WELDABILITY SUPPLEMENT S1, AND/OR
105) AS NOTED ON THE STRUCTURAL DRAWINGS.
11. HEADED ANCHOR STUDS (HAS) SHALL CONFORM TO ASTM A108 AND SHALL BE CONNECTED TO STRUCTURAL
STEEL WITH EQUIPMENT APPROVED BY THE STUD MANUFACTURER ACCORDING TO THE STUD MANUFACTURER'S
RECOMMENDATIONS.
12. WELDING SHALL BE DONE BY A CERTIFIED WELDER IN ACCORDANCE WITH THE AISC DOCUMENTS LISTED ABOVE, THE AMERICAN WELDING SOCIETY (AWS) D1.1: STRUCTURAL WELDING CODE, AND THE RECOMMENDATIONS FOR USE OF WELD E70 ELECTRODES. WHERE NOT SPECIFICALLY NOTED, MINIMUM WELD SHALL BE 3/16" FILLET BY
LENGTH OF CONTACT EDGE.
13. GROUT BENEATH COLUMN BASE AND BEAM BEARING PLATES SHALL HAVE A MINIMUM 28-DAY, COMPRESSIVE STRENGTH OF 7,500 PSI AND SHALL BE NON-SHRINK, NON-METALLIC, AND TESTED IN ACCORDANCE WITH ASTM C1107.
DESIGN LOADS:
1. DESIGN LOADS: TOWN OF BRECKENRIDGE (2018 INTERNATIONAL BUILDING CODE WITH AMENDMENTS); ASCE 7-16
2. RISK CATEGORY: II STANDARD
3. ROOFS:
A. ROOF DEAD LOAD 20 PSF
B. ROOF LIVE LOAD 20 PSF, 300 LBS
C. GROUND SNOW LOAD, Pg 77 PSF (NA PER TOWN OF BRECKENRIDGE AMENDMENTS) D.
This is the start of the file's text. The full file is on GovTribe.