2024 HCS - HIGH SCHOOL RR DRAWINGS.pdf
PDF 976 KB Posted
- Attached to
- Hillsdale High School Roofing Project
- Solicitation number
- RFP - HCS - 240000001297
- Issued by
- Hillsdale County, Michigan
About this file
This document is a set of roof drawings and details for the Hillsdale High School Roofing Project in Hillsdale, Michigan. The scope of work includes making necessary roof repairs, installing new cow tongue suppers, removing and replacing scupper boxes and downspouts, and applying a new roofing system on the high school. The project will be completed in 13 different roof sections totaling 125,300 square feet. The drawings provide detailed specifications for the roof components, including penetrations, curbs, and scuppers.
The thermal imaging report identifies approximately 1,000 square feet of wet insulation that needs to be replaced. The project details and drawings indicate that the contractor must verify the existing roof deck conditions and apply the appropriate details accordingly. Pricing, set asides, and funding information is not provided in the documents.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2024 HCS - HIGH SCHOOL RR Project Manual.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H I
L L
S D
A L
E C
O M
M U
N I
T Y S
C H
O O
L S
S
N O
R W
O O
D S
T
H I
L L
S D
A L
E M
I
SHEET NO.
SHEET TITLE:
APPROVED FOR
BIDDING
COVER
SHEET
A1
HILLSDALE COMMUNITY SCHOOLS
Roof Repairs and Restoration
SUMMARY OF WORK LOCATION MAP
NOTES
SITE MAP
DRAWING INDEX
BUILDING OVERVIEW
HILLSDALE HIGH SCHOOL:
1.) MAKE ANY AND ALL NECESSARY ROOF REPAIRS.
2.) INSTALL NEW COW TONGUE SUPPERS ON WEST ROOF.
3.) REMOVE AND REPLACE SCUPPER BOX AND DOWNSPOUTS ON SOUTH ROOF.
4.) ALLOW REPAIRS TO CURE PROPERLY
5.) CLEAN AND PREP ROOFING SURFACE
6.) APPLY LIQUITEC BASE COAT AT A RATE OF 3 GAL./ SQ. AND EMBED POLYESTER SCRIM
7.)APPLY LIQUITEC TOP COAT AT A RATE OF 2 GAL./ SQ.
MODIFIED REPAIR:
1. SPUD BACK THE EXISTING GRAVEL A MINIMUM OF 4’ FROM THE EXISTING EXPOSED
DRAIN FLASHING.
2. REMOVE THE EXISTING DRAIN FLASHING AND FIELD MEMBRANE A MINIMUM OF 2’
FROM THE EXISTING EXPOSED DRAIN FLASHING.
3. REMOVE AND REPLACE ANY SATURATED MATERIAL, DOWN TO THE ROOF DECK,
AND REPLACE WITH SAME TYPE AND KIND.
4. INSTALL NEW ROOFING MEMBRANE AND DRAIN FLASHING TO RETURN THE ROOF TO
WATERTIGHT.
A1 – COVER PAGE
A2.1 – ROOF PLAN – HIGH SCHOOL
A3.1 – DRAWING – HIGH SCHOOL
T2 – THERMALS – HIGH SCHOOL
D3 – DETAILS – HIGH SCHOOL
ALL COMMENTS, RECOMMENDATIONS, AND
ANALYSIS ARE THE OPINIONS OF THE
INDIVIDUALS COMPLETING THE INSPECTION.
THEY DO NOT CONSTITUTE THE OFFICIAL
POSITION OF THE GARLAND COMPANY. THIS
REPORT WAS NOT GENERATED BY AN ARCHITECT,
ENGINEER, OR CONSULTANT AND DOES NOT HAVE
INDEPENDENT TESTING DATA.
THIS REPORT DOES NOT MAKE ANY CLAIM ON
WHAT A MANUFACTURER CAN, OR WILL,
DETERMINE TO BE PROPER OR IMPROPER DETAILS
OR METHODS. NOR CAN IT MAKE A
DETERMINATION ON WHAT A CONTRACTOR OR
MANUFACTURER WILL, OR WILL NOT, WARRANTY.
HILLSDALE HIGH SCHOOL
HILLSDALE HIGH SCHOOL
30 S NORWOOD AVE
HILLSDALE, MI 49242
HILLSDALE HIGH SCHOOL
L L
S D
A L
E C
O M
M U
N I
T Y S
C H
O O
L S
S
N O
R W
O O
D S
T
H I
L L
S D
A L
E M
I
SHEET NO.
SHEET TITLE:
APPROVED FOR
BIDDING
ROOF
PLAN
A2.1
HILLSDALE HIGH SCHOOL
2024 ROOFING
NOT INCLUDED
SECTION SQUARE FOOTAGE:
SECTION #1: BUR 3,300 SF
SECTION #2: BUR 3,900 SF
SECTION #3: BUR 3,000 SF
SECTION #4: SINGLE-PLY 18,000 SF
SECTION #5: BUR 5,400 SF
SECTION #6: BUR 8,700 SF
SECTION #7: SINGLE-PLY 5,200 SF
SECTION #8: MOD BIT 9,400 SF
SECTION #9: SINGLE-PLY 7,900 SF
SECTION #10: SINGLE-PLY 4,600 SF
SECTION #11: SINGLE-PLY 4,400 SF
SECTION #12: MOD BIT 9,700 SF
SECTION #13: BUR 8,300 SF
SECTION #15: BUR 14,000 SF
SECTION #16: BUR 1,000 SF
SECTION #17: BUR 8,900 SF
SECTION #18: SINGLE-PLY 9,600 SF
TOTAL: 125,300 SF
SECTION SQUARE FOOTAGE:
SECTION #1: BUR 3,300 SF
SECTION #2: BUR 3,900 SF
SECTION #3: BUR 3,000 SF
SECTION #4: SINGLE-PLY 18,000 SF
SECTION #5: BUR 5,400 SF
SECTION #6: BUR 8,700 SF
SECTION #7: SINGLE-PLY 5,200 SF
SECTION #8: MOD BIT 9,400 SF
SECTION #9: SINGLE-PLY 7,900 SF
SECTION #10: SINGLE-PLY 4,600 SF
SECTION #11: SINGLE-PLY 4,400 SF
SECTION #12: MOD BIT 9,700 SF
SECTION #13: BUR 8,300 SF
SECTION #15: BUR 14,000 SF
SECTION #16: BUR 1,000 SF
SECTION #17: BUR 8,900 SF
SECTION #18: SINGLE-PLY 9,600 SF
TOTAL: 125,300 SF
8 9
10 11
DENOTES REPAIR AREA
L L
S D
A L
E C
O M
M U
N I
T Y S
C H
O O
L S
S
N O
R W
O O
D S
T
H I
L L
S D
A L
E M
I
SHEET NO.
SHEET TITLE:
APPROVED FOR
BIDDING
ROOF
DRAWING
A3.1
ROOF DRAWINGS:
HILLSDALE HIGH SCHOOL
DRAIN
ROUND CURB PENETRATION
EXHAUST
LADDER
LEGEND
PIPE / PENETRATION
CURB
CHIMNEY
TAPERED INSULATION
HVAC UNITRTU
DRAIN
ROUND CURB PENETRATION
EXHAUST
LADDER
LEGEND
PIPE / PENETRATION
CURB
CHIMNEY
TAPERED INSULATION
HVAC UNITRTU
D3
D3
D3
D3
D3
D3
D2
D2
D3
D3
D3
D3
L L
S D
A L
E C
O M
M U
N I
T Y S
C H
O O
L S
S
N O
R W
O O
D S
T
H I
L L
S D
A L
E M
I
SHEET NO.
SHEET TITLE:
APPROVED FOR
BIDDING
THERMAL
IMAGING
T1
THERMAL SCAN RESULTS:
2024 ROOFING
THERMAL SCAN INFORMATION:
SECTION: WET INSULATION:
TOTAL: 1,000 (+/-) SF
THERMAL SCAN INFORMATION:
SECTION: WET INSULATION:
TOTAL: 1,000 (+/-) SF
PONDING WATER
WET INSULATION
L L
S D
A L
E C
O M
M U
N I
T Y S
C H
O O
L S
S
N O
R W
O O
D S
T
H I
L L
S D
A L
E M
I
SHEET NO.
SHEET TITLE:
APPROVED FOR
BIDDING
HIGH
SCHOOL
DETAILS
D3
N.T.S.D1
1 TYPICAL FIELD DETAIL
N.T.S.D1
2 PERIMETER EDGE DETAIL
N.T.S.D1
3 CURB DETAIL
N.T.S.D1
4 PIPE PENETRATION DETAIL
1) Details shown are representative of finished details. Contractors shall take into account existing insulation, new insulation, and the new roof system. Wood blocking shall be added to achieve the minimum flashing heights shown.
1) Details shown are representative of finished details. Contractors shall take into account existing insulation, new insulation, and the new roof system. Wood blocking shall be added to achieve the minimum flashing heights shown.
Detail Requirements
2) Deck types vary between roof areas and buildings. Contractor must verify roof decks and apply details accordingly.
1) Details shown are representative of finished details. Contractors shall take into account existing insulation, new insulation, and the new roof system. Wood blocking shall be added to achieve the minimum flashing heights shown.
Detail Requirements
2) Deck types vary between roof areas and buildings. Contractor must verify roof decks and apply details accordingly.
N.T.S.D1
5 SCUPPER
N.T.S.D1
5 SCUPPER BOX TO DOWN SPOUT
N.T.S.D1
6 SCUPPER BOX TO DOWN SPOUT
Extend supper min 1.5" out from fascia.
| 2024 HIllsdale Details and Drawings - 01.03.2024.vsdx |
| A1 |
| A2.1 |
| A3.1 |
| T2 |
| D3 |
File details come from the government source that posted it. Updated .