2024 Guardrail Bid Sheet D6 - Addendum 2.xls
XLS spreadsheet 66 KB Posted
- Attached to
- Guardrail Maintenance Repair-Supplemental D6
- Solicitation number
- RFB 605 2400000656 3
- Issued by
- Kentucky
About this file
2024 Guardrail Bid Sheet D6 - Addendum 2
This is a bid sheet for guardrail maintenance and installation services for District 6 of the Kentucky Transportation Cabinet (KYTC). The solicitation encompasses a comprehensive range of guardrail-related work items including installation, removal, repair, and maintenance of standard guardrails, radius rails, terminal sections, end treatments, bridge guardrail posts, crash cushions, and cable barrier systems. The estimated usage quantities span from as few as 1 unit for lane closures to 150,000 linear feet for cable barrier tension checks, with work measured in various units including each (EA), linear feet (LNFT), and hours (HR). The bid sheet specifies 101 distinct line items, with work categorized by whether materials are furnished by the department or the vendor.
Vendors are required to bid all line items to be considered for award, with actual bid prices to be entered directly on this bid sheet and uploaded into the state's e-procurement system. The vendor identified is Eden Fence under customer code VC0000093662. Pricing should reflect both labor and materials as applicable to each item, with certain items including incidental work or materials (such as concrete for anchor blocks or traffic control). The scope includes specialized work such as Corten guardrail installation, various end treatment types, bridge connections, delineator installation, and cable barrier system maintenance requiring adherence to manufacturer specifications and state standards, including KYTC specifications and approved concrete suppliers with minimum design strength of 3500 psi.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Final Items List
| Vendor: | Vendor Rep Information (name, phone, email address): | |||||||||
| DISTRICT ___6___ | Instructions: Vendors shall bid all lines to be considered for award. Actual bid prices must be entered on this bid sheet and uploaded into the e-procurement system. | |||||||||
| VENDOR CUSTOMER CODE | SUPPLIER NAME | MANUFACTURER NAME | MANUFACTURER PART NUMBER | COMMODITY CODE | # | Item Description | Estimated | |||
| Usage | Unit | Unit Price | Total | Extended Description | ||||||
| VC0000093662 | Eden Fence | 91223 | 1 | Lane Closure | 500 | EA | Lane Closure | |||
| 2 | Lane Closure for Night Work | 25 | EA | Lane Closure for Night Work - This item includes all lane closures used outside of daylight hours. | ||||||
| 3 | Shoulder Closure | 75 | EA | Shoulder Closure | ||||||
| VC0000093662 | Eden Fence | 91223 | 4 | Shoulder Closure for Night Work | 25 | EA | Shoulder Closure for Night Work - This item includes all shoulder closures used outside of daylight hours. | |||
| 5 | Install Guardrail (Furnished by Department) | 20000 | LNFT | Install Guardrail ( Furnished by Department) | ||||||
| 6 | Install Guardrail (Furnished by Vendor) | 10000 | LNFT | Install Guardrail ( Furnished by Vendor) | ||||||
| 7 | Install Radius Rail (Furnished by Department) | 250 | LNFT | Install Radius Rail (Furnished by Department) | ||||||
| 8 | Install Radius Rail (Furnished by Vendor) | 250 | LNFT | Install Radius Rail (Furnished by Vendor) | ||||||
| 9 | Realign Guardrail | 7500 | LNFT | Realign Guardrail | ||||||
| 10 | Remove Guardrail | 30000 | LNFT | Remove Guardrail | ||||||
| 11 | Remove & Reset Guardrail | 5000 | LNFT | Remove & Reset Guardrail | ||||||
| 12 | Install Steel Guardrail Post 6' (Furnished by Department) | 4000 | EA | Install Steel Guardrail Post ( Furnished by Department) | ||||||
| 13 | Install Steel Guardrail Post 6' (Furnished by Vendor) | 2000 | EA | Install Steel Guardrail Post ( Furnished by Vendor) | ||||||
| 14 | Install Steel Guardrail Post 7' (Furnished by Department) | 500 | EA | Install Steel Guardrail Post ( Furnished by Department) | ||||||
| 15 | Install Steel Guardrail Post 7' (Furnished by Vendor) | 500 | EA | Install Steel Guardrail Post ( Furnished by Department) | ||||||
| 16 | Install Steel Guardrail Post 9' (Furnished by Department.) | 500 | EA | Install Steel Guardrail Post 9' ( Furnished by Dept.) | ||||||
| 17 | Install Steel Guardrail Post 9' (Furnished by Vendor) | 250 | EA | Install Steel Guardrail Post 9' ( Furnished by Vendor) | ||||||
| 18 | Install Timber Guardrail Post | 50 | EA | Install Timber Guardrail Post ( Furnished by Vendor) | ||||||
| 19 | Remove & Reset Guardrail Post (Timber or Steel) | 7500 | EA | Remove & Reset Guardrail Post (Timber or Steel) | ||||||
| 20 | Remove Guardrail Post (Timber or Steel) | 6000 | EA | Remove Guardrail Post (Timber or Steel) | ||||||
| 21 | Install Offset Block (Furnished by Department) | 7500 | EA | Install Wood Offset (Furnished by Department) | ||||||
| 22 | Install Offset Block (Furnished by Vendor) | 3000 | EA | Install Wood Offset Block ( Furnished by Vendor) | ||||||
| 23 | 8” Guardrail Offset Blocks-Composite (Furnished by Department) | 500 | EA | Install 8" Composite Offset Block (Furnished by Department) | ||||||
| 24 | 8" Guardrail Offset Blocks-Composit (Furnished by Vendor) | 200 | EA | Install 8" Composite Offset Block (Furnished by Vendor) | ||||||
| 25 | Remove & Reset Offset Block | 2500 | EA | Remove & Reset Offset Block | ||||||
| 26 | Remove Offset Block | 7500 | EA | Remove Offset Block | ||||||
| 27 | Install Terminal Section No.1 | 50 | EA | Install Terminal Section No. 1 (Furnished by Dept.) | ||||||
| 28 | Install Terminal Section No.1 | 50 | EA | Install Terminal Section No. 1 ( Furnished by Vendor) | ||||||
| VC0000093662 | Eden Fence | 91223 | 29 | Install Terminal Section No.2 | 2 | EA | Install Terminal Section No. 2 (Furnished by Vendor) | |||
| 30 | Install Terminal Section No.3 | 2 | EA | Install Terminal Section No. 3 ( Furnished by Vendor) | ||||||
| 31 | Remove Terminal Section No. 1 | 100 | EA | Remove Terminal Section No. 1 | ||||||
| 32 | Remove Terminal Section No. 2 | 10 | EA | Remove Terminal Section No. 2 | ||||||
| 33 | Remove & Reset Terminal Sections | 50 | EA | Remove & Reset Terminal Sections | ||||||
| 34 | Install Guardrail - Corten | 250 | LNFT | Install Guardrail - Corten (Furnished by Vendor) | ||||||
| 35 | Paint End Treatment to match Core Ten Guardrail | 2 | EA | Paint End Treatment to match Core Ten Guardrail | ||||||
| 36 | Install Bridge Guardrail Post-Case 1 | 50 | EA | Install Bridge Guardrail Post - Case 1 (Furnished by Vendor) | ||||||
| 37 | Install Bridge Guardrail Post-Case 1A | 10 | EA | Install Bridge Guardrail Post - Case 1A (Furnished by Vendor) | ||||||
| VC0000093662 | Eden Fence | 91223 | 38 | Install Bridge Guardrail Post-Case 1B | 5 | EA | Install Bridge Guardrail Post - Case 1B (Furnished by Vendor) | |||
| 39 | Install Bridge Guardrail Post-Case 2 | 20 | EA | Install Bridge Guardrail Post - Case 2 (Furnished by Vendor) | ||||||
| 40 | Remove Bridge Post Case 1 | 10 | EA | Remove Bridge Post Case 2 | ||||||
| 41 | Remove Bridge Post Case 1A | 10 | EA | Remove Bridge Post Case 1A | ||||||
| 42 | Remove Bridge Post Case 1B | 10 | EA | Remove Bridge Post Case 1B | ||||||
| 43 | Remove Bridge Post Case 2 | 10 | EA | Remove Bridge Post Case 3 | ||||||
| 44 | Remove and Reset Case-Post (all type) | 10 | EA | Remove and Reset Case-Post (all type) | ||||||
| 45 | Install Crash Cushion Type IX, IX-A | 5 | EA | Install Crash Cushion Type IX, Type IX-A ( Furnished by Vendor) | ||||||
| VC0000093662 | Eden Fence | 91223 | 46 | Remove & Replace 10g Slotted Rail | 50 | LNFT | Remove and Replace 10 GAGE Slotted Rail for Crash Cushion Type IX or IX-A (Furnished by Ven) | |||
| 47 | Remove & Replace 12g Slotted Rail | 50 | LNFT | Remove and Replace 12 GAGE Slotted Rail for Crash Cushion Type IX or IX-A (Furnished by Ven) | ||||||
| 48 | Remove & Replace Nose & Side Panels | 2 | EA | Remove and Replace Nose and Side Panels for Crash Cushion Type IX or IX-A (Furnished by Ven) | ||||||
| 49 | Remove & Replace Post #1 & Offset Block | 10 | EA | Remove and Replace Post # 1 and Offset Block for Crash Cushion Type IX or IX-A (Furnished by Ven) | ||||||
| 50 | Remove & Replace Post #2-6 & Offset Block | 5 | EA | Remove and Replace Post # 2-6 and Offset Block for Crash Cushion Type IX or IX-A (Furnished by Ven) | ||||||
| VC0000093662 | Eden Fence | 91223 | 51 | Remove Crash Cushion Type IX, IX-A | 10 | EA | Remove Crash Cushion Type IX, IX-A | |||
| VC0000093662 | Eden Fence | 91223 | 52 | Install End Treatment Type 1 (MSKT) | 50 | EA | Install End Treatment Type 1-MSKT ( Furnished by Vendor) | |||
| 53 | Install End Treatment Type 1 (Soft Stop) | 50 | EA | Install End Treatment Type 1-Soft Stop (Furnished by Vendor) | ||||||
| 54 | Install End Treatment Type 2A | 10 | EA | Install End Treatment Type 2A (Furnished by Vendor) | ||||||
| VC0000093662 | Eden Fence | 91223 | 55 | Install End Treatment Type 3 | 5 | EA | Install End Treatment Type 3 (Furnished by Vendor) | |||
| 56 | Install End Treatment Type 4A | 15 | EA | Install End Treatment Type 4A (Furnished by Vendor) | ||||||
| 57 | Install End Treatment Type 7 | 10 | EA | Install End Treatment Type 7 (Furnished by Vendor) | ||||||
| 58 | Remove & Replace 10g Guardrail-End Treatment Type 1 | 100 | LNFT | Remove and Replace 10 GAGE Guardrail for End Treatment Type 1 (Furnished by Vendor) | ||||||
| 59 | Install Extruder head for Type 1 End Treatment (MSKT) | 10 | EA | Install Extruder head for Type 1 End Treatment, MSKT (Furnished by Vendor) | ||||||
| 60 | Install Impact head for type 1 End Treatment (Soft Stop) | 10 | EA | Install Impact head for type 1 End Treatment, Soft Stop (Furnished by Vendor) | ||||||
| 61 | Repair End Treatment , Type 1 (MSKT) | 30 | EA | Repair End Treatment (MSKT) , Type 1 (Vendor furnish 1st Rail and Post 1). Removing and resetting the extruder head is incidental to this work. | ||||||
| 62 | Repair End Treatment, Type 1 (Soft Stop) | 10 | EA | Repair End Treatment (Soft Stop), Type 1, (Vendor Furnish 1st Rail and Post 1). Removing and resetting impact head is incidental to this work | ||||||
| 63 | Remove & Replace Post & Offset Blocks Type 1 | 50 | EA | Remove and Replace Post and Offset Blocks for End Treatment Type 1 (MSKT and Soft Stop) Furnished by Vendor | ||||||
| 64 | Remove & Reset Extruder Head for Type 1 End Treatment (MSKT) | 100 | EA | Remove and Reset Extruder Head for Type 1 End Treatment (MSKT) | ||||||
| 65 | Remove & Reset Impact head for Type 1 End Treatment (Soft Stop) | 10 | EA | Remove and Reset Extruder Head for Type 1 End Treatment (Soft Stop) | ||||||
| 66 | Remove & Replace Post & Offset Blocks Type 4A | 30 | EA | Remove and Replace Post and Offset Blocks for End Treatment Type 4A (Furnished by Vendor) | ||||||
| 67 | Repair End Treatment, Type 4A | 5 | EA | Repair End Treatment, Type 4A (Vendor Furnish 1st Rail, Terminal and Post). Removing and resetting the terminal section for End Treatment Type 4A is incidental to this work. | ||||||
| 68 | Remove & Replace Slotted Guardrail for End Treatment Type 4A | 100 | LNFT | Remove and Replace Slotted Guardrail for End Treatment Type 4A (Furnished by Vendor) | ||||||
| 69 | Remove & Replace Terminal Section for Type 4A | 15 | EA | Remove and Replace Terminal Section for End Treatment Type 4A (Furnished by Vendor) | ||||||
| 70 | Install Wood Post for End Treatment Type 7 | 20 | EA | Install Wood Post for End Treatment Type 7 (Furnished by Vendor) | ||||||
| 71 | Remove End Treatment (All Types) | 50 | EA | Remove End Treatment (All Types) | ||||||
| 72 | Install Guardrail Conn to Bridge End Type A | 5 | EA | Install Guardrail Conn to Bridge End Type A ( Furnished by Vendor) | ||||||
| 73 | Install Guardrail Conn to Bridge End Type A1 | 5 | EA | Install Guardrail Conn to Bridge End Type A1 ( Furnished by Vendor) | ||||||
| 74 | Install Guardrail Conn to Bridge End Type C | 5 | EA | Install Guardrail Conn to Bridge End Type C ( Furnished by Vendor) | ||||||
| 75 | Install Guardrail Conn to Bridge End Type D | 5 | EA | Install Guardrail Conn to Bridge End Type D ( Furnished by Vendor) | ||||||
| 76 | Install Delineators for Guardrail-Mono Directional White | 1000 | EA | Install Delineators for Guardrail - Mono Directional White (Furnished by Vendor) | ||||||
| VC0000093662 | Eden Fence | 91223 | 77 | Install Delineators for Guardrail-Mono Directional Yellow | 1000 | EA | Install Delineators for Guardrail - Mono Directional Yellow (Furnished by Vendor) | |||
| VC0000093662 | Eden Fence | 91223 | 78 | Install Delineators for Guardrail Bi-Directional White | 1000 | EA | Install Delineators for Guardrail - Bi-Directional White (Furnished by Vendor) | |||
| 79 | Remove & Replace Cable Barrier End Anchor | 25 | EA | Remove and Replace End Anchor - Work shall consist of removal of cables from the end treatment, removal and disposal of damaged end anchor, replacement of end treatment connectors and concrete anchor block. In addition, this item also includes reinstallation and re-tensioning of the cables and regrading around the anchor block. NOTE: Only concrete from a State-approved ready mix supplier, with a minimum design strength of 3500 psi will be allowed for this item Concrete shall be incidental to this item. | ||||||
| VC0000093662 | Eden Fence | 91223 | 80 | Remove & Replace Cable Barrier End Post (Furnished by Department) | 20 | EA | Remove and Replace Cable Barrier End Anchor Post - Work shall consist of removal of damaged post, replacement with a new post and proper alignment of cable around, through, or along post, dependent on manufacturer. In addition, this item includes the replacement of all hardware needed for proper cable height including, but not limited to spaces, pegs, hook pins, locking plates, caps, reflectors, etc. | |||
| 81 | Remove & Replace Cable Barrier End Post (Furnished by Vendor) | 100 | EA | Remove and Replace Cable Barrier End Anchor Post - Work shall consist of removal of damaged post, replacement with a new post and proper alignment of cable around, through, or along post, dependent on manufacturer. In addition, this item includes the replacement of all hardware needed for proper cable height including, but not limited to spaces, pegs, hook pins, locking plates, caps, reflectors, etc. | ||||||
| VC0000093662 | Eden Fence | 91223 | 82 | Remove & Replace Cable Barrier Line Post (Furnished by Department) | 500 | EA | Remove and Replace Cable Barrier Post - Work shall consist of removal and disposal of damaged post and hardware, replacement with a new post and proper alignment of cable around, through, or alongside post, dependent on manufacturer. In addition, this item includes the replacement of all hardware needed for proper cable height including, but not limited to spaces, pegs, hook pins, locking plates, caps, reflectors, etc. | |||
| 83 | Remove & Replace Cable Barrier Line Post (Furnished by Vendor) | 2000 | EA | Remove and Replace Cable Barrier Post - Work shall consist of removal and disposal of damaged post and hardware, replacement with a new post and proper alignment of cable around, through, or alongside post, dependent on manufacturer. In addition, this item includes the replacement of all hardware needed for proper cable height including, but not limited to spaces, pegs, hook pins, locking plates, caps, reflectors, etc. | ||||||
| 84 | Remove & Replace Cable Barrier Post Base | 25 | EA | Remove and Replace Cable Barrier Post Base - Work shall consist of removal and disposal of damaged base and replacement with a new sleeve and concrete. Site mixed / bag mix concrete will be permitted for the replacement of the post base, with a minimum strength of 3500 psi. This concrete shall be incidental and will not be paid as a separate item. | ||||||
| VC0000093662 | Eden Fence | 91223 | 85 | Reattach Cable for Cable Barrier System | 40 | EA | Reattach Cable for Cable Barrier System - This item shall be reimbursement for all labor, equipment, and materials needed to reattach any cable that has either been cut, severed, or released from the end anchor. This price shall be paid per cable to be reattached. | |||
| VC0000093662 | Eden Fence | 91223 | 86 | Check & Adjust Tension for Cable Barrier System | 150,000 | LNFT | Check Tension of Cable Barrier System and Adjust as needed. Follow manufacturer's recommendations for checking and adjusting tension. This item shall not be paid when incidental to other line items. | |||
| 87 | Remove & Replace Cable Barrier Post Hardware | 1000 | EA | Remove and Replace Cable Barrier Post Hardware (Gibraltar System) - Work shall consist of removal and disposal of damaged hardware, replacement with new hardware for proper alignment of cable along the undamaged post. This line item shall only be used when the post can be re-used, but the hardware is damaged and warrants replacement. | ||||||
| 88 | Repair / Replace Combination Fitting | 1 | EA | Repair / Replace Combination Fitting | ||||||
| 89 | Repair / Replace Turnbuckle | 5 | EA | Repair / Replace Turnbuckle | ||||||
| 90 | Remove and Replace Concrete Mow Strip for Cable Barriers | 100 | LNFT | Remove damaged concrete mow strip and post sleeves. Form up and pour new concrete mow strip in accordance with KYTC specifications. Backfill against new concrete mow strip. This item includes all labor, equipment, and materials necessary to make these repairs. Traffic control will be paid under a separate line item. | ||||||
| 91 | Replace Cable for Cable Barrier System | 1000 | LNFT | This item shall include all labor, equipment and materials necessary to replace the cable for the cable barrier system. When determined by the Engineer that the cable is damaged and in need of replacing, the vendor shall furnish the necessary length of cable and install the new cable in order to restore the cable barrier system to the manufacturer’s specifications. This item shall only be used when it becomes necessary to replace the cable.Replace Cable for Cable Barrier System (Vendor furnish cable) | ||||||
| 92 | Scrap Metal Credit | 10000 | LNFT | The Vendor shall provide a Scrap Metal Credit of $1.00 per linear foot of damaged guardrail retained by the Vendor. | ||||||
| 93 | Remove Guardrail Connector to Bridge End | 2 | LNFT | Remove Guardrail Connector to Bridge End (All Types) | ||||||
| 94 | Thrie Beam GR – FBV | 500 | LNFT | Thrie Beam GR – FBV | ||||||
| 95 | Thrie Beam Transition to SF GR – FBV | 5 | EA | Thrie Beam Transition to SF GR – FBV | ||||||
| 96 | Install Thrie Beam Offset Block | 1000 | EA | Install Thrie Beam Offset Block | ||||||
| 97 | Install Thrie Beam Post (6'9" W6 x 8.5# standard) | 1000 | EA | Install Thrie Beam Post (6'9" W6 x 8.5# standard) | ||||||
| 98 | Install Thrie Beam Terminal Section End | 5 | EA | Install Thrie Beam Terminal Section End | ||||||
| 99 | Install Thrie Beam Bridge Post | 100 | EA | Thrie Beam Bridge post (W6 x 15# x 2’1” tall with ¾” x 10”x 14”base plate) for use across bridge applications | ||||||
| 100 | Side Mounted MGS Post | 50 | EA | Install Railing System Side Mounted MGS Post according to standard drawing BHS-011 | ||||||
| 101 | Law Enforcing Officer | 250 | HR | This item shall include scheduling, officer, vehicle with blue lights, ins., and taxes. With 4 hour minimum when it is required. |
File details come from the government source that posted it. Updated .