These architectural drawings are electrical lighting plans for Delta College's Main Campus Lighting Replacement project, prepared by MacMillan Associates Consulting Engineers for Delta College in Bay City, Michigan. The documents detail demolition and revised lighting plans for the first and second floor theaters, showing comprehensive electrical modifications including fixture replacements, wireless control installations, and electrical system upgrades. The plans specify replacing existing light fixtures "one for one" with new fixtures, installing new wireless control stations, replacing existing lighting control panels, and modifying electrical circuits to support new lighting infrastructure.
The drawings outline specific technical requirements for electrical contractors, including installing Unistrut parallel to fixtures, mounting new fixtures independently, providing junction boxes, installing wireless powerpack systems for dimming control, and implementing 15VDC and 24VDC power supplies for occupancy sensors. The project involves detailed electrical work in the theater spaces, with a focus on creating a flexible, modernized lighting system that allows independent fixture control and integrates wireless technology. The drawings are dated 5/23/2024 and are part of project number 2023-2304, indicating a current infrastructure improvement initiative for Delta College's main campus theater spaces.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2024.05.07 Delta College Main Campus Lighting Replacement IFC ELEC.pdf | ||
| General .pdf | ||
| 2023-2302.002 ADDENDUM #1.DOC | DOC document | |
| 2023-2304 Elec Spec 5.7.24.pdf | ||
| Proposal form.doc | DOC document | |
| Insurance Requirements.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C O
N S
U
LT
IN
G
E N
G
IN
E E
R S
M ac
M
IL
LA
N
A S
S O
C
IA
TE
S
B A
Y C
IT
Y
, M
IC
H
IG
A N
E
A S
T M
ID
LA
N D
S T
R E
E T
D el ta C ol le ge
NORTH
KEY PLAN
NOT TO SCALE
FIRST FLOOR THEATER - DEMOLITION LIGHTING PLAN
1/8"=1'-0"
NORTH
SECOND FLOOR THEATER - DEMOLITION LIGHTING PLAN
1/8"=1'-0"
NORTH
DT3
DT3
DT3
DT3
DT1
EX
EX
EX
EX
EX
KEYED NOTES
REPLACE EXISTING LIGHT FIXTURE ONE FOR
ONE WITH NEW. UNISTRUT TO REMAIN.
REFER TO NEW PLAN. REMOVE EXISTING
BALLASTS AND BALLAST ENCLOSURES.
PROPERLY DISPOSE OF ACCORDING TO LOCAL
REGULATIONS.
REMOVE EXISTING LIGHTING CONTROL DEVICE
INCLUDING ALL WIRING BACK TO THE SOURCE.
ROUGH-IN TO BE REUSED FOR NEW
TOUCHPANEL. REFER TO REVISED PLAN.
REMOVE EXISTING LUTRON GRAFIK EYE
LIGHTING CONTROL PANEL. REPLACE WITH A
NEW PANELBOARD. REFER TO REVISED PLAN.
EXISTING EMERGENCY WALL MOUNT FIXTURE
TO REMAIN.
REMOVE EXISTING SWITCHBANK. BLANK OFF
WITH STAINLESS STEEL COVER PLATE. DESIGN
INTENT IS FOR NEW THEATER FIXTURES TO BE
WIRELESSLY CONTROLLED.
REMOVE EXISTING SURFACE MOUNTED
SWITCH. REMOVE WIRE BACK TO SOURCE.
REMOVE ASSOCIATED CONDUIT, HANGARS,
ETC.
REMOVE RECESSED SWITCH. EXISTING
ROUGH-IN TO BE REUSED FOR NEW WIRELESS
CONTROL SWITCH. USE EXISTING CIRCUIT TO
POWER NEW SWITCH.
EX LUTRON
GRAFIK EYE
TYP
TYP
TYP
TYP
TYP
2 EX
NL/EL
EX
EX
EX
EX
EX
EX
4 4
EX
LP-ZA
EX
DP-Z
EX THEATER
CONTROL
PANELS
EX LP-ZA1
EX
LP-X
TYP
F:
\2
3- D
EL
TA
\2
3-
D el ta
C ol le ge
M ai n Ca m pu s L ig ht in g Re pl ac em en t\
-2
4-
E- E2
TH
EA
TE
R
LI
GH
TI
N G
D
EM
O .D
W G, /2
3/
:0 7:
P
M
C O
N S
U
LT
IN
G
E N
G
IN
E E
R S
M ac
M
IL
LA
N
A S
S O
C
IA
TE
S
B A
Y C
IT
Y
, M
IC
H
IG
A N
E
A S
T M
ID
LA
N D
S T
R E
E T
D el ta C ol le ge
NORTH
KEY PLAN
NOT TO SCALE
FIRST FLOOR THEATER - LIGHTING PLAN
1/4"=1'-0"
NORTH
SECOND FLOOR THEATER - REVISED LIGHTING PLAN
1/4"=1'-0"
NORTH
EX
LP-ZA1
EX
LP-X
EX
LP-ZA
EX
DP-Z
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D D D D D D D
KEYED NOTES
ELECTRICAL CONTRACTOR SHALL INSTALL UNISTRUT PARALLEL
TO TYPE D FIXTURES. MOUNT NEW UNISTRUT ON EXISTING
UNISTRUT. MOUNT TYPE D FIXTURE TO NEW UNISTRUT. DO NOT
DAISY-CHAIN FIXTURES. PROVIDE JUNCTION BOX AT EACH
FIXTURE. DESIGN INTENT IS THAT ANY TYPE D FIXTURE COULD
BE REMOVED INDEPENDENTLY OF THE REST.
PROVIDE NEW WIRELESS CONTROL STATION. MODIFY AND
EXTEND NEARBY LIGHTING CIRCUIT TO PROVIDE 120V POWER
TO SWITCH.
ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL
WIRELESS POWERPACK FOR DIMMING CONTROL OF TYPE D
FIXTURES.
ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL 15VDC
POWER SUPPLY IN ACCESSIBLE CEILING SPACE TO POWER
OCCUPANCY SENSOR. MODIFY AND EXTEND EXISTING LIGHTING
CIRCUIT AS REQUIRED TO FEED THE POWER SUPPLY.
INSTALL WIRELESS CONTROL SWITCH IN EXISTING ROUGH-IN.
POWER SWITCH FROM EXISTING CONDUCTORS. SWITCH SHALL
ONLY CONTROL FIXTURES IN THE THEATER CONTROL ROOM.
ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL
OCCUPANCY SENSOR IN SOFFIT. POWER WITH 15VDC FROM THE
POWER SUPPLY ON THE SECOND FLOOR.
USE 24VDC OUTPUT FROM POWERPACK TO POWER THE FIRST
FLOOR THEATER OCCUPANCY SENSORS. ROUTE 24VDC WIRING
THROUGH SOFFIT SPACE AFTER THE DOWNLIGHTS HAVE BEEN
REMOVED.
FURNISH AND INSTALL 3-GANG GRAPHIC TOUCHPANEL.
TOUCHPANEL SHALL WIRELESSLY CONTROL THEATER
FIXTURES.
FURNISH AND INSTALL NEW BREAKER PANELBOARD AS A
DIRECT REPLACEMENT FOR THE EXISTING LUTRON GRAFIK EYE
LIGHTING CONTROL PANEL EQUIPPED WITH A MAIN CIRCUIT
BREAKER AND 20 AMP BRANCH CIRCUIT BREAKERS.
1 TYP
B4
B4
B4
B4
B4
B4E
B4B4B4
B4E B4E B4E
B4E
B4
B4
B4
B4
B4
EX STAGE
CONTROL
PANELS
THEATER
DIMMER PNL
D20D20
D20D20
D05
S5
PP
PS
S G
S4
F1F1F1EF1F1
F1F1F1F1 F1
NL/EL
EX
EX
EX
EX
EX
EX
EXISTING THEATER UP LIGHTING
(FOR REFERENCE ONLY)
TYP
PP
PP
PP
PP
GENERAL NOTES
1. REPLACE EXISTING LIGHT FIXTURES "ONE FOR ONE" WITH
NEW, TYPICAL. REUSE EXISTING LIGHTING CIRCUIT.
7 7
F:
\2
3- D
EL
TA
\2
3-
D el ta
C ol le ge
M ai n Ca m pu s L ig ht in g Re pl ac em en t\
-2
4-
E- E5
TH
EA
TE
R
LI
GH
TI
N G
RE
VI
SE
D
.D W
G, /2 3/
:0
7:
P M
| Sheets and Views |
| 2023-2304-E-E2 - THEATER LIGHTING DEMO-Model |
| 2023-2304-E-E5 - THEATER LIGHTING REVISED-Model |
File details come from the government source that posted it. Updated .