2024_01_18 T2305 High Point Final Plans Resub.pdf
PDF 4 MB Posted
- Solicitation number
- PE-66098-NONST-2024-000000035
- Issued by
- Fulton County, Georgia
About this file
This document appears to be a set of construction plans and specifications for the City of Sandy Springs Project T2305 High Point Road Pedestrian Crosswalk, located in Fulton County, Georgia. The scope of work includes improving pedestrian safety along High Point Road through the installation of various traffic control devices, signage, pavement markings, and pedestrian crossing enhancements. The project has a total length of approximately 0.95 miles and includes the construction of concrete sidewalks, pedestrian ramps, curb and gutter, and drainage improvements. Key components include a new rectangular rapid flashing beacon assembly, video detection system, and the placement of thermoplastic pavement markings and traffic striping.
The document provides detailed construction plans, typical sections, summary of quantities, utility plans, signing and marking plans, and signal plans. It also includes general notes, erosion control details, and specifications related to materials, workmanship, and project requirements. No specific bid due date or award information is included, as this appears to be the final construction plan set rather than a solicitation document. Pricing terms, funding sources, and other commercial details are not included in this technical plan set.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24_053 T2305 High Point Road Pedestrian Cross.pdf | ||
| SP Combined.pdf | ||
| ITB_24_053 Addendum 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MILES
DEPARTMENT OF TRANSPORTATION
STATE OF GEORGIA
PLANS COMPLETED - -
REVISIONS
PLAN AND PROFILE OF PROPOSED
NET LENGTH OF EXCEPTIONS
GROSS LENGTH OF PROJECT
NET LENGTH OF ROADWAY
NET LENGTH OF BRIDGES
NET LENGTH OF PROJECT
LENGTH OF PROJECT
LOCATION SKETCH (N.T.S)
SUBSECTIONS 102.04, 102.05, AND 104.03 OF THE SPECIFICATIONS.
OF TRANSPORTATION IN ANY WAY. THE ATTENTION OF BIDDER IS SPECIFICALLY DIRECTED TO
SAME ARE SHOWN AS INFORMATION ONLY, ARE NOT GUARANTEED, AND DO NOT BIND THE DEPARTMENT
FIELD INVESTIGATIONS AND ARE BELIEVED TO BE INDICATIVE OF ACTUAL CONDITIONS. HOWEVER, THE
INDICATED THEREBY, WHETHER BY DRAWINGS OR NOTES, OR IN ANY OTHER MANNER, ARE BASED UPON
THE DATA, TOGETHER WITH ALL OTHER INFORMATION SHOWN ON THESE PLANS OR IN ANYWAY
THE DEPARTMENT OF TRANSPORTATION.
STATE HIGHWAY DEPARTMENT OF GEORGIA, AND SHALL BE DEEMED TO MEAN
DEPARTMENT ", OR " DEPARTMENT " WHEN THE CONTEXT THEREOF MEANS THE
HIGHWAY DEPARTMENT ", GEORGIA STATE HIGHWAY DEPARTMENT ", " HIGHWAY
WITH THIS DOCUMENT, TO " STATE HIGHWAY DEPARTMENT OF GEORGIA ", "STATE
DOCUMENTS, DRAWINGS, OR PHOTOGRAPHS USED, OR TO BE USED IN CONNECTION
ALL REFERENCES IN THIS DOCUMENT, WHICH INCLUDES ALL PAPERS, WRITINGS,
NOTE :
APPROVAL DATE:
LOCATION & DESIGN
OF 1988.
AMERICAN VERTICAL DATUM (NAVD)
1983)/94 WEST ZONE, AND THE NORTH
COORDINATE SYSTEM OF 1984 (NAD
USING THE HORIZONTAL GEORGIA
THIS PROJECT HAS BEEN PREPARED BY:
PLANS PREPARED
http://mydocs.dot.ga.gov/info/gdotpubs/ConstructionStandardsAndDetails/Forms/AllItems.aspx
PROJECT LOCATION
PROJECT NO. T2305
01-0001
MID-POINT COORDINATES
T2305
Project No.
COUNTY No.121
FULTON
SPEED DESIGN: 35 MPH
24 HR.TRUCKS %: N/A
% TRUCKS: N/A
DIRECTIONAL DIST: N/A
TRAFFIC D.H.V.: N/A
TRAFFIC A.D.T.: N/A
TRAFFIC A.D.T.: N/A
DESIGN DATA: N/A
100% IN CONG. DIST. NO. 5.
FUTLON COUNTY AND IS
THIS PROJECT IS 100% IN
PROJECT DESIGNATION: EXEMPT
E X I S T
R
W E
X I S
W
E X I S
W E
X I S
W
EXIST. R/W
EXIST. R/W
N 1416353.7250
E 2235590.1573
STA. 103+50.00 HIGH POINT RD
EXIST. R/W
0.0000
0.0000
STANDARDS AND DETAILS BOOK WHICH THEY REVISE OR IN WHICH THERE IS A CONFLICT.
ANY REVISIONS CONTAINED WITHIN THIS PLAN SET SUPERSEDE THE 2023 CONSTRUCTION
CONSTRUCTION STANDARDS AND DETAILS BOOK IS AVAILABLE AT:
STANDARDS AND DETAILS BOOK AND ATTACHED APPLICABLE REVISIONS. THE 2023
THESE PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE 2023 CONSTRUCTION
FUNCTIONAL CLASS: COLLECTOR
0.0947
PEDESTRIAN CROSSING DESIGN
5080 HIGH POINT ROAD
12/8/2023 winnie.gobbel
GPLOT-V8
gplotborder-V8i-PO.tbl
00T2305_01-0001.dgn
GRWCOV
CONCOV
DRAWING No.
T S
A T
E
O GF
E
O
R G
I A
C
O
NSTITUTIO
N
JUSTICE OM DER
ATIONDOM
WIS
100 200
SCALE IN FEET
0 50
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
FOREST HILLS DR
H I
G H
P
O I
N
D
STA. 101+27.23
BEGIN CONSTRUCTION
100+00
105+00
E 2235591.6289
N 1416603.7207
STA. 106+00.00
END PROJECT T-2305
STA. 105+58.50
END CONSTRUCTION
E 2235587.2794
N 1416103.7443
STA. 101+00.00
BEGIN PROJECT T-2305
Peachtree Corners, Georgia 30092
3930 East Jones Bridge Road, Suite 350
Engineering, Planning, and Environmental Consultants
5080 HIGH POINT ROAD, SANDY SPRINGS, GA 30342
winnie.gobbel Image winnie.gobbel Image
DESCRIPTIONDESCRIPTION
INDEX
DRAWING NO. DRAWING NO.
01-0001
02-0001
23-0001 TO 23-0004
COVER SHEET
INDEX
TYPICAL SECTION
03-0001 REVISION SUMMARY SHEET
GENERAL NOTES
EARTHWORK CROSS SECTIONS
UTILITY PLANS
SUMMARY OF QUANTITIES
05-0001
06-0001
13-0001
BMP LOCATION DETAILS
52-0001 CONST. DETAIL (EC-L1) - EROSION CONTROL LEGEND AND UNIFORM CODE SHEET (SHEET 1 OF 7) (03-17)
LAST REV.
CONSTRUCTION PLAN SHEETS
02-0001
24-0001
26-0001 SIGNING & MARKING PLANS
27-0001 TO 27-0005 SIGNAL PLANS
THE GEORGIA CONSTRUCTION DETAILS AND STANDARDS HAVE NOT BEEN PROVIDED IN THE PLAN SET.
REFER TO THE 2023 CONSTRUCTION STANDARDS AND DETAILS BOOK
54-0001
EROSION CONTROL DETAILS
D-54 SOD INSTALLATION (04-16)56-0001
04-0001 TO 04-0002
REVISION DATES
12/8/2023 winnie.gobbel
GPLOT-V8
gplotborder-V8i-PO.tbl
00T2305_02-0001.dgn
12:27:19 PM
GPLN10/23/2015
DRAWING No.CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
PEDESTRIAN CROSSING DESIGN
5080 HIGH POINT ROAD, SANDY SPRINGS, GA 30342
REVISION
REVISION SUMMARY
03-
DRAWING NO.DATE DATE DRAWING NO. REVISION
03-0001
REVISION DATES
12/8/2023 winnie.gobbel
GPLOT-V8
00T2305_03-0001.dgn
12:27:21 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
PEDESTRIAN CROSSING DESIGN
GENERAL NOTES:
TO BE REMOVED OR RELOCATED TO CLEAR CONSTRUCTION IN ADVANCE OF HIS WORK.
FACILITIES WHICH ARE IN CONFLICT WITH CONSTRUCTION AND ARE NOT COVERED AS SPECIFIC ITEMS IN THE DETAILED ESTIMATE ARE
UTILITY THAT EXISTS ON THE HIGHWAY PROJECT IN ITS ORIGINAL, RELOCATED, OR NEWLY INSTALLED POSITION. ALL UTILITY
WILL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY UNDER THIS REQUIREMENT. "EXISTING UTILITY FACILITIES" MEANS ANY
AS TO PLAN OR ELEVATION. UTILITY FACILITIES SUCH AS SERVICE LINES OR UNKNOWN FACILITIES NOT SHOWN ON HIGHWAY PLANS
2. ALL KNOWN UTILITY FACILITIES ARE SHOWN SCHEMATICALLY ON HIGHWAY PLANS AND ARE NOT NECESSARILY ACCURATE IN LOCATION
AS WELL AS GDOT STANDARDS AS A BACKUP SOURCE.
1. ALL WORK TO BE DONE IN ACCORDANCE WITH CITY OF SANDY SPRINGS TECHNICAL MANUAL AND CODE, CURRENT EDITION,
3. THE FOLLOWING UTILITIES HAVE FACILITIES IN THE PROJECT AREA:
CONTACT INFORMATIONSERVICEUTILITY OWNER
DESCRIPTIONS OF MONUMENTS USED.
7. HORIZONTAL CONTROL IS BASED UPON GEORGIA STATE PLANE COORDINATE SYSTEM. SEE CONSTRUCTION PLANS FOR LOCATIONS AND
ANY UNSUITABLE OR WASTE MATERIAL.
6. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO FURNISH SUITABLE BORROW MATERIAL FOR THE PROJECT AND DISPOSE OF
IF THE CONTRACTOR RELIES ON THE AREA SHOWN ON THE PLANS. THE ESTIMATED TOTAL AREA FOR GRASSING IS 0.1 ACRES.
RESPONSIBILITY TO DETERMINE THE ACTUAL AREA TO BE GRASSED. NO CLAIMS WILL BE CONSIDERED FOR EXTRA COMPENSATION
NO RESPONSIBILITY FOR ITS ACCURACY. THE CONTRACTOR SHALL BID ON GRASSING COMPLETE, LUMP SUM, AND IT SHALL BE HIS
5. THE TOTAL AREA SHOWN ON THE PLANS FOR GRASSING IS FOR INFORMATION ONLY. THE CITY OF SANDY SPRINGS ASSUMES
FOR GRADING COMPLETE - LUMP SUM.
BE PERIODICALLY WATERED, SUFFICIENT TO RETARD DUST. ALL COSTS FOR DUST CONTROL SHALL BE INCLUDED IN PRICE BID
4. THE CONTRACTOR SHALL STRICTLY ADHERE TO DUST CONTROL REGULATIONS. ALL AREAS SUBJECTED TO DUST FORMATION MUST
15. ALL CONCRETE SIDEWALKS AND WHEELCHAIR RAMPS LOCATED IN THE RADIUS RETURN SHALL BE 8" THICKNESS.
OUTSIDE THE LIMITS OF CONSTRUCTION, SHALL NOT BE DISTURBED UNLESS DIRECTED BY THE ENGINEER.
14. STRUCTURES, TREES, SHRUBS AND OTHER PLANT MATERIAL THAT FALL WITHIN THE RIGHT-OF-WAY AND EASEMENT LIMITS, BUT
IF NECESSARY. TYPE OF RAMP MAY BE MODIFIED AS DIRECTED BY THE ENGINEER.
13. HANDICAP RAMPS SHALL BE CONSTRUCTED AT ALL POINTS WHERE SIDEWALK TERMINATES AT CURB OR IS BISECTED BY DRIVEWAYS, OF UNIFORM TRAFFIC CONTROL DEVICES" CURRENT EDITION AND/OR AS DIRECTED BY THE ENGINEER.
TRAFFIC DURING CONSTRUCTION. ALL TEMPORARY SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH THE "MANUAL
OF TEMPORARY SIGNING AND PAVEMENT MARKINGS, BARRICADES, CHANNELIZING DEVICES, ETC. REQUIRED FOR MAINTENANCE OF
12. PRICE BID FOR TRAFFIC CONTROL-LUMP SUM SHALL INCLUDE, BUT IS NOT LIMITED TO, CONSTRUCTION, MAINTENANCE, AND REMOVAL
CONSTRUCTION.
PROVISIONS FOR TRAFFIC CONTROL AND SEQUENCE OF OPERATIONS IN REGARDS TO MAINTENANCE OF TRAFFIC DURING
11. THE CONTRACTOR’S ATTENTION IS DIRECTED TO ARTICLES 104.05 & 107.07 OF THE STANDARD SPECIFICATIONS AND THE SPECIAL
PAVEMENT NOT PROPERLY STRIPED.
TRAFFIC CONTROL DEVICES," CURRENT EDITION OR AS DIRECTED BY THE ENGINEER. TRAFFIC SHALL NOT BE ALLOWED ON ANY
CONFUSE THE TRAVELING PUBLIC. ALL REMAINING LINES OR MARKINGS SHALL BE IN ACCORDANCE WITH THE "MANUAL ON UNIFORM
THE CONTRACTOR SHALL REMOVE OR OVERLAY LINES TO THE SATISFACTION OF THE ENGINEER SUCH THAT THE LINES DO NOT
10. WHERE EXISTING PAVEMENT MARKINGS AND LINES ARE IN CONFLICT WITH THE TRAFFIC PATTERN BEING USED ON CONSTRUCTION, BID FOR OTHER CONTRACT ITEMS, EXCEPT WHEN SAWING P.C.C. CONCRETE PAVEMENT.
ENSURE PAVEMENT REMOVAL TO A NEAT LINE. THE COST FOR SAWED JOINTS, WHEN REQUIRED, SHALL BE INCLUDED IN PRICE
CURBING IS TO BE PLACED ACROSS A PAVED AREA, A JOINT SHALL BE SAWED ON A LINE ESTABLISHED BY THE ENGINEER TO
9. AT LOCATIONS WHERE NEW PAVEMENT IS TO BE PLACED ADJACENT TO EXISTING PAVEMENT WITHOUT AN OVERLAY OR WHERE
AS DIRECTED BY THE ENGINEER. COST FOR REMOVAL SHALL BE INCLUDED IN THE PRICE FOR GRADING COMPLETE.
8. ALL EXISTING PIPES AND DRAINAGE STRUCTURES SHALL BE RETAINED UNLESS OTHERWISE NOTED ON PLANS TO BE REMOVED OR
18. A NOTICE OF INTENT (NOI) IS NOT REQUIRED FOR THIS PROJECT. THE DISTURBED AREA IS 0.03 ACRES.
WILL BE MADE FOR ANY COSTS INCURRED TO COMPLY WITH THIS REQUIREMENT.
AT SPECIFIC LOCATIONS IN THE PLANS AND HAVING SPECIFIC PAY ITEMS IN THE DETAILED ESTIMATE. NO SEPARATE PAYMENT
THAT HAVE BEEN DAMAGED OR REMOVED OR REGRADED AS REQUIRED BY THE ENGINEER EXCEPT FOR THOSE DRAINAGE ITEMS SHOWN
LIMITS. THIS MAY INCLUDE, BUT IS NOT LIMITED TO, REPLACEMENT OR RECONSTRUCTION OF EXISTING DRAINAGE STRUCTURES
17. THE CONTRACTOR SHALL ENSURE THAT POSITIVE AND ADEQUATE DRAINAGE IS MAINTAINED AT ALL TIMES WITHIN THE PROJECT
BY THE ENGINEER AND PAID FOR UNDER GRADING COMPLETE. REFER TO SECTION 161 OF THE STANDARD SPECIFICATIONS.
IN ORDER TO REDUCE EROSION. IF THE SEASON DOES NOT PERMIT GRASSING, TEMPORARY MULCH SHALL BE USED AS DIRECTED
16. ALL CUT AND FILL SLOPES SHALL BE GRASSED AS DIRECTED BY THE ENGINEER IMMEDIATELY AFTER THE SLOPES ARE ESTABLISHED
04-0001
GENERAL NOTES
ATLANTA GAS LIGHT GAS 678-492-9807
CITY OF ATLANTA WATER 404-546-3519
AT&T TELECOMMUNICATION 305-409-1542
COMCAST TELECOMMUNICATION 678-708-7112
FULTON COUNTY SEWER 404-612-4248
GEORGIA POWER 404-506-6539
MARTA 404-848-6944
ELECTRICITY
ELECTRICITY
winnie.gobbel
GPLOT-V8
00T2305_04-0001.dgn
12:27:23 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
PEDESTRIAN CROSSING DESIGN
GENERAL NOTES
04-0002
THE DETOUR ROUTE SERVES.
13. ALL M4-9 SIGNS SHALL HAVE ADVISORY BLADES INSTALLED BELOW THE "DETOUR" SIGN IDENTIFYING THE CLOSED STREET THAT
AT NO ADDITIONAL EXPENSE TO THE DEPARTMENT.
CONDITIONS WARRANT. IF ADDITIONAL TRAFFIC CONTROL DEVICES ARE REQUIRED THESE SHALL BE PROVIDED BY THE CONTRACTOR
12. THE CITY OF SANDY SPRINGS RESERVES THE RIGHT TO MODIFY THIS MAINTENANCE OF TRAFFIC PLAN AS FIELD
EQUALS THE DESIGN SPEED LIMIT FOR THE TAPER.
11. REFLECTORIZED DRUMS SHALL BE PROVIDED FOR CHANNELIZATION OF TRAFFIC IN ALL TRAFFIC SHIFTS. MAXIMUM SPACING
ALONG ANY ADJACENT SIDE ROAD OR DRIVEWAY.
10. ALL TRAFFIC CONTROL DEVICES SHALL BE MAINTAINED BY THE CONTRACTOR SO AS TO NOT INTERFERE WITH SIGHT DISTANCE
9. THE CONTRACTOR SHALL MAINTAIN INGRESS AND EGRESS TO DRIVEWAYS AT ALL TIMES.
FROM THE EDGE OF THE TRAVEL LANES UNLESS PRIOR APPROVAL IS GRANTED BY THE DEPARTMENT OF TRANSPORTATION.
8. ALL REFLECTORIZED PLASTIC DRUMS AND TEMPORARY CONCRETE BARRIERS SHALL BE PLACED A MINIMUM OF 2 FEET (0.6 M)
TYPE I AND TYPE II BARRICADES AND CONES SHALL NOT BE USED.
7. ONLY REFLECTORIZED PLASTIC DRUMS AND TEMPORARY CONCRETE BARRIERS SHALL BE USED ADJACENT TO TRAVEL LANES.
OR PAVING OVER. "BLACK OUT" PAINT IS PROHIBITED.
6. EXISTING PAVEMENT MARKINGS THAT CONFLICT WITH TRAFFIC SHIFTS SHALL BE OBLITERATED BY THE CONTRACTOR BY GRINDING
RELATED TRAFFIC CONTROL DEVICES.
REPLACING DAMAGED AND STOLEN SIGNS, AND PERIODIC CLEANING OF EXISTING SIGNS, BARRELS, AND OTHER CONSTRUCTION
5. EXISTING TRAFFIC SIGNS SHALL BE MAINTAINED BY THE CONTRACTOR THROUGHOUT CONSTRUCTION. MAINTENANCE INCLUDES
4. IN RESIDENTIAL AREAS SIGNS SHALL BE LOCATED ON, OR AS CLOSE AS POSSIBLE TO, PROPERTY LINES.
PANELS ARE PROHIBITED.
3. ALL TEMPORARY SIGNS SHALL HAVE HIGH INTENSITY REFLECTORIZED SHEETING ON METAL SIGN PANELS. PLYWOOD SIGN
HIGHWAY SIGNS, (LATEST EDITIONS).
2. ALL SIGNS AND PAVEMENT MARKINGS SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, AND STANDARD
CONTROL, LUMP SUM.
1. ALL ITEMS NECESSARY FOR COMPLIANCE WITH THESE REQUIREMENTS SHALL BE INCLUDED IN THE PRICE BID FOR TRAFFIC
MAINTENANCE OF TRAFFIC
GENERAL NOTES (CONT’D):
22. ALL PROPOSED DETECTABLE WARNING STRIPS SHALL BE RED AND MEET SANDY SPRINGS STANDARDS.
THIS WORK SHALL BE PAID FOR UNDER PAY ITEM 210-0100 GRADING COMPLETE.
21. TRIM ALL TREE LIMBS TO PROVIDE A MINIMUM OF 8’ CLEARANCE ABOVE THE SIDEWALK. ENSURE SIGNAL HEAD AND SIGN VISIBILITY.
20. UNLESS OTHERWISE SPECIFIED OR DIRECTED BY THE INSPECTOR, ALL WATER LINES SHALL HAVE A MINIMUM OF 48 INCHES OF COVER.
REQUIREMENT SHALL BE INCLUDED IN THE BID ITEM COST FOR NO. 700-9300 - SOD.
NO SEPARATE PAYMENT WILL BE MADE FOR ANY COST INCURRED TO COMPLY WITH THIS REQUIREMENT. THE TOTAL COST OF THIS
WHICH MAY BE PLANTED AND GROWING ON THE ADJACENT LAWN, I.E. BERMUDA SOD FOR BERMUDA SOD, ZOYSIA FOR ZOYSIA, ETC.
19. TYPE OF SOD USED ON THIS PROJECT, UNLESS OTHERWISE SHOWN, WILL BE REQUIRED TO MATCH ANY TYPE OF GRASS OR SOD winnie.gobbel
GPLOT-V8
00T2305_04-0001.dgn
12:45:15 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
PEDESTRIAN CROSSING DESIGN
TYPICAL SECTIONS
05-0001
SIDEWALK
6’-0"
REQUIRED PAVEMENT
A
B
C
D
EXIST. PAVEMENT TO BE RETAINED
CONCRETE SIDEWALK, 4"
A
D
B C
CL
EXIST
0’-6"
TRAVEL LANE
12’-0"
1’-6"
D
B
0’-6"
CL
0’-0" TO 2’-0"
VARIES
VARIES
SHOULDER
D
SOD
E REMOVE EXIST. PAVEMENT
E
E
C
CONC HEADER CURB, 6 IN, TP 2 (GA. STD. 9032B)
SHOULDER VARIES
10’-0"
12’-0" TO 15’-9"
TRAVEL LANE VARIES
SEE PLANS FOR SIDEWALK CROSS-SLOPE DETAILS
EXIST
Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
N.T.S.
REVISION DATES
12/8/2023 winnie.gobbel
GPLOT-V8
00T2305_05-0001.dgn
12:27:26 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
2% MAX
T2305
2:1 TYP
2% MAX
2:1 MAX
2:
MAX
STA. 103+24.00 TO STA. 104+46.55
HIGH POINT RD
TS-02
STA. 104+46.55 TO STA. 104+68.45
STA. 102+52.99 TO STA. 103+24.00
HIGH POINT RD
TS-01
PEDESTRIAN CROSSING DESIGN
SUMMARY OF QUANTITIES
SUMMARY QUANTITIES
06-0001
QUANTITY LUMP SUM
LUMP SUMQUANTITY
TRAFFIC CONTROL - T2305
GRADING COMPLETE - T2305
QUANTITY
QUANTITY
QUANTITY
CONC SIDEWALK, 4 IN
CONC SIDEWALK, 8 IN
23 SY
SUMMARY OF QUANTITIES - STANDARD SIGNS
STATION
INSTL.
NO.
SIGN
CODE
HIGHWAY SIGNS POST
TP 1 MATL,
TYPE 7 TYPE 8
SIZE QUANTITY
FEET
SQUARE
(FEET)
LENGTH
QUANTITY
LENGTH
TOTAL
(FEET)
LENGTH
QUANTITY
LENGTH
TOTAL
(FEET)
LENGTH
QUANTITY
LENGTH
TOTAL
TYPE 8 W/ TYPE 9 INSERT
(EA)
EXIST.
RESET
REFL SHEETING TP 9
(EA)
EXIST.
REMOVE
REFL SHEETING TP 11
TP 1 MATL,
SIZE QUANTITY
FEET
SQUARE
SIZE
FEET
SQUARE
QUANTITY
TP 2 MATL,
REFL SHEETING TP 9
(EA)
SUPPORT
BREAKAWAY
MOUNTED
GROUND
QUANTITY
MULCH
QUANTITY
AGRICULTURAL LIME
QUANTITY
FERTILIZER MIXED GRADE
QUANTITY
1 TN
1 TN
SOD
FERTILIZER NITROGEN CONTENT
SIGNAL QUANTITIES UNIT TOTAL
QUANTITY 2 EA
QUANTITY
THERMOPLASTIC SOLID TRAF STRIPE, 5 IN, WHITE
QUANTITY
STRIPE, 5 IN, WHITE
THERMOPLASTIC SKIP TRAF
QUANTITY 396 LF
QUANTITY
STRIPE, 24 IN, WHITE
THERMOPLASTIC SOLID TRAF
STRIPE, 8 IN, WHITE
THERMOPLASTIC SOLID TRAF
49 SY
232 LF
TOTAL
AS DIRECTED
STA. 105+58.49
STA. 104+58.50
STA. 104+25.38
STA. 103+95.30
STA. 103+83.04
STA. 103+57.35
STA. 103+40.46
STA. 103+22.46
STA. 103+05.30
STA. 102+27.14
STA. 102+07.83
STA. 101+27.23
36" X 36"
24" X 12"
30" X 30"
30" X 30"
30" X 30"
24" X 8"
36" X 36"
18" X 24"
12" X 36"
12" X 36"
18" X 24"
24" X 12"
30" X 30"
30" X 30"
36" X 36"
W3-4
W16-9P
W11-2
R10-15A(L)
R10-15A(R)
S4-3P
S1-1
R560-5
R1-6A
R1-6A
R560-5
W16-9P
W11-2
R10-15A(R)
W3-4
75.58
6.25
6.25
6.25
1.33
6.25
6.25
14.5
14.5
14.5
14.5
CONCRETE HEADER CURB, 6 IN, TP 2
QUANTITY 60 SF
DETECTABLE WARNING SURFACE
1 LB
4 TN
QUANTITY 75 SY
THERMOPLASTIC PAVEMENT MARKING ARROW, TP 2
124 LF
80 GLF
48 LF
QUANTITY
THERMOPLASTIC TRAF STRIPING, WHITE
POWDER COATED AUTOMATIC GREEN
STEEL STRAIN POLE, TP IV, INCL LUMINAIRE ARM,
RRFB INSTALLATION NO - 1
VIDEO DETECTION SYSTEM, NO - 1
RECTANGULAR RAPID BEACON ASSEMBLY
EA
LS
LS
EA 4
QUANTITY
REMOVE EXIST TRAF MARKINGS - T2305
LUMP SUM
24 SY
LS 1TESTING - VIDEO DETECTION SYSTEM
1/17/2024 winnie.gobbel
GPLOT-V8
00T2305_06-0001.dgn
7:30:16 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
PEDESTRIAN CROSSING DESIGN
13-0001
CONSTRUCTION PLAN
WILLIAM PARK PRIOR TO ANY TREE WORK.
ARBORIST. CONSULT WITH URBAN FOREST COORDINATOR
1. TREE PRUNING TO BE CONDUCTED BY A CERTIFIED
NOTE:
+99.30
37.55’
+53.69
14.50’
EXIST. FENCE
DO NOT DISTURB
EXIST. FENCE
DO NOT DISTURB
R
EXIST. UTILITY POLE
DO NOT DISTURB
EXIST. UTILITY POLE
DO NOT DISTURB
+63.95
3.50’1
+63.95
2.50’1
EXIST. FIRE HYDRANT
DO NOT DISTURB
25’R
+54.95
12.50’
TP 2 HEADER CURBTP 2 HEADER CURB
DO NOT DISTURB TREE
1 EXISTING CREPE MYRTLE TO BE REMOVED
EXIST. TREE TO BE TRIMMED
EXIST. TREE TO BE TRIMMED
winnie.gobbel
GPLOT-V8
00T2305_13-0001.dgn
12:27:43 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
SCALE IN FEET
0 40 80
PROPERTY AND EXISTING R/W LINE
REQUIRED R/W LINE
EASEMENT FOR CONSTR
& MAINTENANCE OF SLOPES
EASEMENT FOR CONSTR
& MAINTENANCE OF DRAINAGE
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
PL CONSTRUCTION LIMITS
LIMIT OF ACCESS
REQ’D R/W & LIMIT OF ACCESS
ORANGE BARRIER FENCE
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
DROP INLETCATCH BASIN
OUTFLOW CONTROL DEVICE
JUNCTION BOXMANHOLE
C F
Peachtree Corners, Georgia 30092
3930 East Jones Bridge Road, Suite 350
Engineering, Planning, and Environmental Consultants
PEDESTRIAN CROSSING DESIGN
5080 HIGH POINT ROAD
5080 HIGH POINT ROAD, SANDY SPRINGS, GA 30342
6’ SIDEWALK
P I
HIGH POINT ROAD
F O
R E S
H
L L
F O
R E
L
D R I
V E
W A
Y B E T
H
T E F I L L
A H
E 2235587.2794
N 1416103.7443
STA. 101+00.00
BEGIN PROJECT T-2305
E 2235591.6289
N 1416603.7207
STA. 106+00.00
END PROJECT T-2305
RAMP, TP B
RAMP, TP B
RAMP, TP D
RAMP, TP D
STA. 103+98.91, 50.10’ LT
TIE TO EXIST. HEADER CURB
STA. 103+23.75, 27.03’ RT
TIE TO EXIST. SIDEWALK
STA. 103+38.75, 27.11’ RT
TIE TO EXIST. SIDEWALK
EXIST. SIDEWALK TO REMAIN
STA. 101+27.23
BEGIN CONSTRUCTION
STA. 105+58.50
END CONSTRUCTION
STA. 104+25.01, 36.80’ LT
TIE TO EXIST. HEADER CURB
STA. 104+68.45, 15.21’ LT
TIE TO EXIST. HEADER CURB
RED DETECTABLE WARNING STRIPS
REPLACE WITH SANDY SPRINGS STANDARD
RED DETECTABLE WARNING STRIPS
REPLACE WITH SANDY SPRINGS STANDARD
DB 51502, PG 535
(5058 HIGH POINT ROAD)
CAROLYN PRICE MASSICOTT
DB 60115, PG 288
(5072 HIGH POINT ROAD)
SAMUEL SILVER & BARBARA CONVENY
DB 52130, PG 408
(5042 HIGH POINT ROAD)
DAVID AUTOPOLSKY
DB 50128, PG 416
(5098 HIGH POINT ROAD)
ERICA KAYZ
DB 52260, PG 259
(5065 HIGH POINT ROAD)
CONGREGATION BETH TEFILLAH, INC
DB 43994, PG 349
(605 FOREST HILLS DRIVE)
JAMES MICHAEL TORCIVIA
DB 43994, PG 349
(600 FOREST HILLS DRIVE)
MITCHELL & CHERYL A. TEPPER
DB 64173, PG 266
(5105 HIGH POINT ROAD)
MENACHEM EIZICOVIES
PL
PL
PL
PL
PL
EXIST. R/W
EXIST. R/W
EXIST. R/W EXIST. R/W EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
C
P
IN
V B
.0
P
IN
V A
.1
T O
P
.3
S W
B
A
A
B
A
B
P
IN
V B
.0
M
P
IN
V A
.3
T O
P
.6
J
CANNOT SEE PIPES
TOP = 991.71
SWCB
C
M P
IN
V B
.1
P
IN
V A
.4
T O
P
.9
P e a c h tre e
C o rn e rs , G e o rg ia
S u ite
, 3
E a s t J o n e s
B rid g e
R o a d
E n g in e e rin g , P la n n in g , a n d
E n v iro n m e n ta l C o n s u lta n ts
O S S
S E
C T I
O N S
E X I S
W E
X I S
W E
X I S
W E
X I S
W E
X I S
W E
X I S
W
C
A L E
IN
F
E E
T
S A
N D
Y
S P
R I
N G S
G E
O R
G I
A
P R
O J E
U
M B E
R
T
STA. 101+00.00
BEGIN PROJECT
STA. 101+27.23
BEGIN CONSTRUCTION
G
L
O T
V g p l o t b o r d e r
V i P
O t b l
T d g n
P
M w i n n i e g o b b e l
S U
X E
N
R E V I S I O N
D A T E S
D R
A W
IN
o
C H E
C K E
D
B A
C K
C H E
C K E
D
C O
R R E
C T E
D
V E
R I F I E
D
D A T E
D A T E
D A T E
D A T E
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
101+00
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
101+20
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
101+40
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
101+60
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
101+80
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
102+00
1.
2.
3.
4.
6.
7.
G H
P
O I
O
A D
G H
P
O I
A D
S
A N
D Y
S P
R I
N G a c h tre e
C o rn e rs , G e o
S u ite
, 3
E a s t J o n e s
B rid g e
R o a d
E n g in e e rin g , P la n n in g , a n d
E n v iro n m e n ta l C o n s u lta n ts
O S S
S E
C T I
O N S
E X I S
W E
X I S
W E
X I S
W E
X I S
W E
X I S
W E
X I S
N D
Y
S P
R I
N G S
G E
O R
G I
A
P R
O J E
M B E
R
T
S C
A L E
IN
F
E E
T
L
O T
V g p l o t b o r d e r
V i P
O t b l
T d g n
P
M w i n n i e g o b b e l
S U
X E
N
R E V I S I O N
D A T E S
D R
A W
C H E
C K E
D
B A
C K
C H E
C K E
D
C O
R R E
C T E
D
V E
R I F I E
D
D A T E
D A T E
D A T E
D A T
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
102+20
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
102+40
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
102+60
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
102+80
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
103+00
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
103+20
8.
9.
0.
1.
2.
3.
2.00%
2.00%
2.00%
2.00%
G H
P
O I
A D
G H
P
O I
A D
S
A N
D Y
S P
R I
N G a c h tre e
C o rn e rs , G e o
S u ite
, 3
E a s t J o n e s
B rid g e
R o a d
E n g in e e rin g , P la n n in g , a n d
E n v iro n m e n ta l C o n s u lta n ts
FOREST HILLS RD
FOREST HILLS RD
O S S
S E
C T I
O N S
E X I S
W E
X I S
W E
X I S
W E
X I S
W E
X I S
N D
Y
S P
R I
N G S
G E
O R
G I
A
P R
O J E
M B E
R
T
S C
A L E
IN
F
E E
T
L
O T
V g p l o t b o r d e r
V i P
O t b l
T d g n
P
M w i n n i e g o b b e l
S U
X E
N
R E V I S I O N
D A T E S
D R
A W
C H E
C K E
D
B A
C K
C H E
C K E
D
C O
R R E
C T E
D
V E
R I F I E
D
D A T E
D A T E
D A T E
D A T
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
103+40
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
103+60
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
103+80
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
104+00
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
104+20
4.
5.
6.
7.
8.
2.00%
2.00%
2.00%
2:1
2:1
2:1
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
104+40
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
104+60
2.00% 2:1
G H
P
O I
A D
G H
P
O I
A D
S
A N
D Y
S P
R I
N G a c h tre e
C o rn e rs , G e o
S u ite
, 3
E a s t J o n e s
B rid g e
R o a d
E n g in e e rin g , P la n n in g , a n d
E n v iro n m e n ta l C o n s u lta n ts
O S S
S E
C T I
O N S
E X I S
W E
X I S
W E
X I S
W E
X I S
W E
X I S
W E
X I S
W E
X I S
N D
Y
S P
R I
N G S
G E
O R
G I
A
P R
O J E
M B E
R
T
S C
A L E
IN
F
E E
T
STA. 105+58.50
END CONSTRUCTION
STA. 106+00.00
END PROJECT
G P L
O T
V g p l o t b o r d e r
V i P
O t b l
T d g n
P
M w i n n i e g o b b e l
S U
X E
N
R E V I S I O N
D A T E S
D R
A W
C H E
C K E
D
B A
C K
C H E
C K E
D
C O
R R E
C T E
D
V E
R I F I E
D
D A T E
D A T E
D A T E
D A T
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
104+80
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
105+00
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
105+20
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
105+40
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
105+60
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
105+80
0 10 20 30 40 50 60 70 80 85-10-20-30-40-50-60-70-80-85
106+00
0.
0.
1.
2.
3.
4.
5.
G H
P
O I
A D
G H
P
O I
A D
S
A N
D Y
S P
R I
N G
UTILITY PLANS
24-0001
1/18/2024 winnie.gobbel
GPLOT-V8
00T2305_24-0001.dgn
3:00:52 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
SCALE IN FEET
0 40 80
PROPERTY AND EXISTING R/W LINE
REQUIRED R/W LINE
EASEMENT FOR CONSTR
& MAINTENANCE OF SLOPES
EASEMENT FOR CONSTR
& MAINTENANCE OF DRAINAGE
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
PL CONSTRUCTION LIMITS
LIMIT OF ACCESS
REQ’D R/W & LIMIT OF ACCESS
ORANGE BARRIER FENCE
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
DROP INLETCATCH BASIN
OUTFLOW CONTROL DEVICE
JUNCTION BOXMANHOLE
C F
Peachtree Corners, Georgia 30092
3930 East Jones Bridge Road, Suite 350
Engineering, Planning, and Environmental Consultants
PEDESTRIAN CROSSING DESIGN
5080 HIGH POINT ROAD
5080 HIGH POINT ROAD, SANDY SPRINGS, GA 30342
P
HIGH POINT ROAD
F O
R E
L
F O
R E
L
D R I
V E
W A
Y B E T
H
T E F I L L
A H
E 2235587.2794
N 1416103.7443
STA. 101+00.00
BEGIN PROJECT T-2305
E 2235591.6289
N 1416603.7207
STA. 106+00.00
END PROJECT T-2305
STA. 101+27.23
BEGIN CONSTRUCTION
STA. 105+58.50
END CONSTRUCTION
DB 51502, PG 535
(5058 HIGH POINT ROAD)
CAROLYN PRICE MASSICOTT
DB 60115, PG 288
(5072 HIGH POINT ROAD)
SAMUEL SILVER & BARBARA CONVENY
DB 52130, PG 408
(5042 HIGH POINT ROAD)
DAVID AUTOPOLSKY
DB 50128, PG 416
(5098 HIGH POINT ROAD)
ERICA KAYZ
DB 52260, PG 259
(5065 HIGH POINT ROAD)
CONGREGATION BETH TEFILLAH, INC
DB 43994, PG 349
(605 FOREST HILLS DRIVE)
JAMES MICHAEL TORCIVIA
DB 43994, PG 349
(600 FOREST HILLS DRIVE)
MITCHELL & CHERYL A. TEPPER
DB 64173, PG 266
(5105 HIGH POINT ROAD)
MENACHEM EIZICOVIES
PL
PL
PL
PL
PL
EXIST. R/W
EXIST. R/W
EXIST. R/W EXIST. R/W EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
WROUGHT IRON FENCE
W R
O U
G H
T
IR
F
N C
E
W R
O U
G H
T
IR
F
N C
E
WROUGHT IRON FENCE
L A
N D
S C
A P
E
LAN
D S C
AP
IN
G
LIN
E
L A N
D S C
A P
IN
G
L
IN
E
LANDSCAPING LINE
GATE
P
IN
V B
.0
P
IN
V A
.1
T O
P
.3
S W
A
B
A
B
P
IN
V B
.0
P
IN
V A
.3
T O
P
.6
CANNOT SEE PIPES
TOP = 991.71
SWCB
C
M P
IN
V B
.1
P
IN
V A
.4
T O
P
.9
C C
E S
S
IB
L E
T O
P
.9
S S
V
C
IN
V C
.2
C
IN
V B
.2
C
IN
V A
.4
T O
P
.8
S S
C
IN
V
.6
T O
P
.7
S S
SIGNING AND MARKING PLANS
26-0001
PEDESTRIAN CROSSING DESIGN
winnie.gobbel
GPLOT-V8
00T2305_26-0001.dgn
12:28:09 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
PROPERTY AND EXISTING R/W LINE
REQUIRED R/W LINE
EASEMENT FOR CONSTR
& MAINTENANCE OF SLOPES
EASEMENT FOR CONSTR
& MAINTENANCE OF DRAINAGE
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
PL CONSTRUCTION LIMITS
LIMIT OF ACCESS
REQ’D R/W & LIMIT OF ACCESS
ORANGE BARRIER FENCE
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
DROP INLETCATCH BASIN
OUTFLOW CONTROL DEVICE
JUNCTION BOXMANHOLE
C F
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
SCALE IN FEET
0 40 80
Peachtree Corners, Georgia 30092
3930 East Jones Bridge Road, Suite 350
Engineering, Planning, and Environmental Consultants
TP 2 ARROW (TYP.)
5" SKIP WHITE (2’ SEG. 6’ GAP)
24" SOLID WHITE (TYP.)
5" SOLID WHITE
DETAIL "C"
TRAFFIC STRIPING - WHITE
REQ’D 24 SY OF THERMOPLASTIC
8" SOLID WHITE (TYP.)
STA. 105+11.15
EDGE STRIPE
TIE TO EXIST.
PL
PL
PL
PL
PL
EXIST. R/W
EXIST. R/W
EXIST. R/W EXIST. R/W EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
HIGH POINT ROAD
F O
R E
L
F O
R E
L
D R I
V E
W A
Y B E T
H
T E F I L L
A H
E 2235587.2794
N 1416103.7443
STA. 101+00.00
BEGIN PROJECT T-2305
E 2235591.6289
N 1416603.7207
STA. 106+00.00
END PROJECT T-2305
STA. 101+27.23
BEGIN CONSTRUCTION
STA. 105+58.50
END CONSTRUCTION
SIGNAL PLANS
27-0001
SHALL BE INSTALLED FOR EACH FLASHING YELLOW ARROW SIGNAL HEAD.
THE INSTALLATION. AN ADDITIONAL 7-CONDUCTOR, 14 AWG, STRANDED SIGNAL CABLE
PROPOSED AND FUTURE VEHICLE SIGNALS SHALL BE INSTALLED ON ALL FOUR SIDES OF
POLE. A MINIMUM OF ONE 7-CONDUCTOR, 14 AWG, STRANDED SIGNAL CABLE FOR
PROPOSED AND FUTURE PEDESTRIAN SIGNALS SHALL BE INSTALLED AT EACH STRAIN
20. ONE 7-CONDUCTOR, 14 AWG,STRANDED CABLE AND ONE 3-PAIR DETECTOR CABLE FOR
ITEMS OR TO SUBMIT ITEMS FOR TESTING AND APPROVAL.
SPRINGS SHALL BE USED. CONTACT CITY OF SANDY SPRINGS FOR A LIST OF APPROVED
AND PUSH BUTTONS THAT HAVE BEEN TESTED AND PRE-APPROVED BY CITY OF SANDY
19. ONLY THE MODELS OF VEHICLE SIGNAL MODULES, PEDESTRIAN SIGNAL MODULES,
FEEDBACK.
SHALL BE VANDAL RESISTANT WITH A PIEZO SWITCH, LED INDICATION AND AUDIBLE
WITH SIGN ARROW INDICATING THE CROSSING DIRECTION. PEDESTRIAN PUSHBUTTONS
ADAPTER". PEDESTRIAN PUSHBUTTONS SHALL BE INSTALLED WITHIN 10" OF SIDEWALK
PERPENDICULAR CROSSINGS SHALL BE MOUNTED ON A "DOUBLE PUSHBUTTON STATION
18. PUSHBUTTON STATIONS THAT ARE INSTALLED ON A PEDESTAL POLE FOR TWO
NUMERAL LED MODULES.
SHALL BE EQUIPPED WITH COUNTDOWN, UNIFORM APPEARANCE, FULL HAND/ MAN/
WITH ONE-WAY SIDE-OF-POLE POLYCARBONATE BRACKETS. PEDESTRIAN SIGNAL HEADS
PEDESTRIAN SIGNAL HEADS ATTACHED TO CONCRETE STRAIN POLES SHALL BE MOUNTED
POLES SHALL BE MOUNTED WITH "CLAMSHELL" TYPE BRACKET ASSEMBLIES. ALL
17. PEDESTRIAN SIGNAL HEADS ATTACHED TO PEDESTAL POLES AND STEEL STRAIN
LED MODULES.
MADE OF POLYCARBONATE MATERIAL. VEHICLE SIGNAL HEADS SHALL BE EQUIPPED WITH
BLACK IN COLOR. VEHICLE SIGNAL HEADS SHALL HAVE TUNNEL VISORS AND SHALL BE
16. VEHICLE AND PEDESTRIAN SIGNAL HEADS AND HARDWARE SHALL BE GREEN AND
15. SIGNAL HEADS ON MAST ARMS SHALL HAVE BACK PLATES AND BE RIGID MOUNTED.
SEPARATE FROM THE FIBER OPTIC INTERCONNECT CABLE.
TRACING WIRE GROUNDED ON ONE END SHALL BE INSTALLED INSIDE A CONDUIT
UNDERGROUND CONDUIT CONTAINING FIBER OPTIC INTERCONNECT CABLE. AN INSULATED
SANDY SPRINGS CALL (770) 730-5600" SHALL BE INSTALLED DIRECTLY ABOVE ALL
14. WHEN APPLICABLE TO THE PLANS, DETECTABLE MARKING TAPE LABELED "CITY OF
THE ENGINEER.
LENGTH SHALL BE BURIED TO A MINIMUM DEPTH OF 48 INCHES, UNLESS APPROVED BY
RIGID METAL OR ENCASED IN CONCRETE. ALL CONDUIT RUNS GREATER THAN 50 FEET IN
13. CONDUIT UNDER DRIVEWAYS AND ROADWAYS SHALL BE TYPE 3 (SDR II HDPE),
EQUIVALENT CABLE.
LOOP AND PEDESTRIAN DETECTOR CABLES SHALL BE 14 AWG IMSA 50-2 3-PAIR
SHEET. DETECTORS SHALL HAVE SEPARATE LEAD-INS TO THE CONTROLLER CABINET.
12. SHIELDED CABLE SHALL BE USED FOR DETECTOR RUNS, AS SHOWN ON THE DETAIL
TRAFFIC SIGNAL GENERAL NOTES
Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
WHEN REOUIRED, AS DIRECTED BY THE ENGINEER.
WHEN ATTACHING SPAN WIRE OR FIBER OPTIC INTERCONNECT CABLE TO THE POLES,
11. THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL NEW GUYS ON EXISTING POLES
THE CONTROLLER CABINET.
NEW RISER, CONDUIT, CONDUCTORS AND DISCONNECT TO PROVIDE POWER SERVICE INTO
10. WHEN APPLICABLE TO THE PLANS, CONTRACTOR WILL BE REQUIRED TO PROVIDE A
NEW SIGNAL ITEMS PRIOR TO REMOVING EXISTING SIGNALS FROM SERVICE.
9. WHEN APPLICABLE TO THE PLANS, THE CONTRACTOR MUST INSTALL AND TEST ALL
RAISE POWER LINES IF NECESSARY.
8. PROVIDE A MINIMUM OF 10 FEET CLEARANCE BETWEEN POWER LINES AND MAST ARMS.
FACES.
AND A MINIMUM OF 8 FEET MEASURED HORIZONTALLY BETWEEN CENTERS OF SIGNAL
THAN 19 FEET CLEARANCE FROM BOTTOM OF SIGNAL HEADS TO TOP OF ROAD SURFACE
7. SIGNAL HEADS SHALL BE ERECTED TO PROVIDE AT LEAST 17 FEET BUT NO MORE
RETAINED AS SHOWN ON THE PLANS.
OF PAVEMENT SHALL BE MAINTAINED. PLACEMENT OF THE SIGNAL HEADS MUST BE
ARE ACCEPTABLE TO AVOID UNDERGROUND UTILITIES. MINIMUM CLEARANCES FROM EDGE
5 FEET) IN LOCATION OF NEW SIGNAL POLES, AT THE DISCRETION OF THE ENGINEER,
TRAFFIC SIGNAL POLES BEFORE INSTALLATION. MINOR SHIFTS ( UP TO A MAXIMUM OF
6. THE CONTRACTOR SHALL LOCATE UNDERGROUND UTILITIES IN THE VICINITY OF NEW
MAST ARM POLE FOUNDATION SHEET.
5. FOR STRAIN POLE FOUNDATION SIZE AND REINFORCEMENT, SEE STRAIN POLE AND
SIGNAL ENGINEER FOR APPROVAL.
ELECTRICAL / LINE HARDWARE MATERIALS TO THE CITY OF SANDY SPRINGS TRAFFIC
DIMENSIONS OF POLES AND CATALOG CUTS OF PROPOSED SIGNAL EQUIPMENT AND
4. CONTRACTOR SHALL SUBMIT LOAD CALCULATIONS, SHOP DRAWINGS AND FOUNDATION
SPRINGS, ATTN: TRAFFIC SIGNAL ENGINEER.
INSTALLATION WORK.THE CONTRACTOR SHALL SUBMIT DOCUMENTATION TO CITY OF SANDY
3. MATERIAL CERTIFICATION IS REQUIRED PRIOR TO BEGINNING ANY SIGNAL
AND ANSI NATIONAL ELECTRICAL SAFETY CODE.
SERVICES). INSTALLATIONS SHALL MEET CURRENT NFPA NATIONAL ELECTRICAL CODE
EXCEPTIONS AS DIRECTED BY THESE PLANS OR CITY OF SANDY SPRINGS TRAFFIC
SPECIFICATIONS AND STANDARD DETAILS FOR TRAFFIC SIGNAL INSTALLATION (WITH
DEPARTMENT OF TRANSPORTATION CURRENT STANDARD AND SUPPLEMENTAL
2. ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH THE GEORGIA
SUBSEQUENT PUBLISHED RULINGS.
OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, CURRENT EDITION, INCLUDING
I. THE COMPLETE SIGNAL INSTALLATION SHALL CONFORM TO ALL APPROPRIATE PARTS
OF EQUIPMENT.
SHALL COORDINATE WITH SANDY SPRINGS TRAFFIC SERVICES STAFF PRIOR TO DELIVERY
SPRINGS WAREHOUSE: 7477 TROWBRIDGE ROAD, SANDY SPRINGS, GA 30328. CONTRACTOR
OLD CABINET, CABLES, ETC.) SHALL BE REMOVED AND RETURNED TO THE SANDY
31. ALL EXISTING SIGNAL EQUIPMENT (SIGNS, SIGNAL HEADS, ANCILLARY EQUIPMENT,
AT A MINIMUM OF TWO WEEKS PRIOR TO SIGNAL TURN-ON FOR PROGRAMMING.
SHALL PROVIDE NEW 2070LX CONTROLLER TO SANDY SPRINGS TRAFFIC SERVICES STAFF
PROGRAMMING OF SIGNAL TIMING AND TURN-ON OF NEW TRAFFIC SIGNAL. CONTRACTOR
30. SANDY SPRINGS PUBLIC WORKS, TRAFFIC SERVICES, WILL BE RESPONSIBLE FOR
SPRINGS OF ANY ACTIVITY.
CONTRACTOR TO PERFORM ANY WORK ON SAID INFRASTRUCTURE. NOTIFY CITY OF SANDY
CONSTRUCTION ACTIVITIES AND MUST USE A CITY OF SANDY SPRINGS APPROVED
INFRASTRUCTURE (LOOP, LEAD-IN, FIBER OPTICS, CONDUIT, PULL BOX, ETC.) DUE TO
RELOCATION OR DAMAGE TO CITY OF SANDY SPRINGS TRAFFIC SIGNAL OR ATMS
29. THE CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ANY
TO THE CONTROLLER IF LOOP FAILURE OCCURS).
NONCONCURRENTLY. DETECTOR UNIT SHALL BE FAIL SAFE (PROVIDE A CONSTANT CALL
28. LOOP DETECTOR UNIT SHALL ENERGIZE ITS INDIVIDUAL LOOP CHANNELS
IN DELAY OF THE ACTIVATION OF THE NEW TRAFFIC SIGNAL INSTALLATION.
27. ENSURE ALL DETECTION IS INSTALLED PROMPTLY. FAILURE TO DO SO WILL RESULT
ANY PART OF THE SIGNAL OPERATION TO BE INOPERABLE.
INSTALLATION OF NEW SIGNAL EQUIPMENT. AT NO TIME SHALL THE CONTRACTOR CAUSE
LOCATION(S) REQUIRED BY THE PROJECT DURING THE INTERIM PERIOD THROUGH
AND/ OR CONTROL SYSTEM ADJUSTMENTS, INCLUDING TEMPORARY SUPPORT POLE
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC SIGNAL
26. THE CONTRACTOR SHALL MAINTAIN EXISTING TRAFFIC SIGNALS DURING
THE ENGINEER. NO IN-LINE SPLICES SHALL BE MADE IN ANY CABLE.
SPLICES. UNLESS OTHERWISE SPECIFICALLY NOTED IN EACH INSTANCE OR DIRECTED BY
25. ALL SPLICES OF FIBER OPTIC CABLE UNDER THIS CONTRACT SHALL BE FUSION
MAINTAINING ITS OPERATIONS.
24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING EXISTING FIBER AND
23. ALL FIBER JUMPERS ARE INCIDENTAL TO THE SWITCH.
DEVICE.
22. ALL CAT-5 CABLES SHALL BE PROVIDED BY THE CONTRACTOR FOR EACH ETHERNET
GUY ANCHORS SHALL BE GALVANIZED.
21. HOT DIP GALVANIZED WELDLESS RINGS SHALL BE USED FOR SPAN WIRE JUNCTIONS.
winnie.gobbel
GPLOT-V8
00T2305_27-0001.dgn
12:28:13 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
GENERAL NOTES
27-0002 Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
TRAFFIC SIGNAL LEGEND
winnie.gobbel
GPLOT-V8
00T2305_27-0002.dgn
12:28:17 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
TRENCHED CONDUIT
BORED CONDUIT
VIDEO DETECTION CAMERA
6x40 PRESENCE LOOP (QUADRUPOLE)
4-SECTION HEAD W/BACKPLATE
EXISTING SIGNAL PROPOSED SIGNAL
CONTROLLER CABINET
STRAIN POLE
TIMBER POLE
MAST ARM
3-SECTION HEAD
OVERHEAD SIGN
PEDESTAL POLE
CURB CUT RAMP
PULLBOX, TP 2
6x40 PRESENCE LOOP (QUADRUPOLE)
CONDUIT
RAILROAD CONTROLLER
SIGN POST
WV
WM
FH
GV
GM
SD
V
EXISTING UTILITIES
DOWN GUY
CONTROLLER CABINET
STRAIN POLE
TIMBER POLE
DOWN GUY
MAST ARM
OVERHEAD SIGN
PEDESTAL POLE
CURB CUT RAMP
PULLBOX, TP 2
PULLBOX, TP 3
RAILROAD CONTROLLER
SIGN POST
E
HEX ELECTRICAL HAND HOLE
EX COMMUNICATIONS MANHOLE
EX SD MANHOLE
EX DROP INLET
EX CATCH BASIN
EX STORM DRAIN
EX UG CABLE TV
EX OH CABLE TV
EX UG TELEPHONE
EX TELEPHONE POLE
EX OH TELEPHONE
EX TELEPHONE MH
EX SS MANHOLE
EX SANITARY SEWER
EX WATER VALVE
EX WATER METER
EX FIRE HYDRANT
EX WATER LINE
EX GAS VALVE
EX GAS METER
EX GAS LINE
EX. UG ELECTRIC
EX TRANSFORMER
EX POWER POLE
EX. OH ELECTRIC
EXISTING GUY WIRE
PULLBOX, TP 3
STREET LIGHT ON LUMINAIRE ARMSTREET LIGHT ON LUMINAIRE ARM
VIDEO DETECTION CAMERA
4-SECTION HEAD
3-SECTION HEAD W/BACKPLATE
PULLBOX, TP 4/4S
PULLBOX, TP 5/5S
PULLBOX, TP 4/4S
PULLBOX, TP 5/5S
PEDESTRIAN SIGNAL HEADPEDESTRIAN SIGNAL HEAD
SIGN POST SIGN POST
PULLBOX, TP 1 PULLBOX, TP 1
DETECTABLE WARNING SURFACE DETECTABLE WARNING SURFACE
6x6 PULSE LOOP
6x18 CALL LOOP
6x40 PRESENCE LOOP (DIPOLE)
6x6 PULSE LOOP
6x18 CALL LOOP
6x40 PRESENCE LOOP (DIPOLE)
5-SECTION / 4-SECTION T-SHAPED HEAD
WIRELESS SENSOR
SPP RADIO
WIRELESS REPEATER
WIRELESS SENSOR
SPP RADIO
WIRELESS REPEATER
DIGITAL WAVE RADAR UNIT
DIGITAL WAVE RADAR UNIT
ELECTRICAL SERVICE POINT
ELECTRICAL SERVICE POINT
5-SECTION / 4-SECTION T-SHAPED HEAD W/BACKPLATE
6x40 VIRTUAL DETECTION ZONE 6x40 VIRTUAL DETECTION ZONE
LEGEND
27-0003 Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
SIGNAL HEAD
PROPOSED 3-SEC
SIGNAL HEAD
EXISTING 3-SEC
SIGNAL HEAD
RELOCATED 3-SEC
SIGNAL HEAD
PROPOSED 4-SEC
SIGNAL HEAD
(CLUSTER)/T-SHAPED
PROPOSED 5-SEC
SIGNAL HEAD
PEDESTRIAN
SIGNAL LEGEND
PROPOSED RADAR
PROPOSED VIRTUAL DETECTION ZONE
PROPOSED INDUCTIVE LOOP
PROPOSED VIDEO DETECTION CAMERA
PROPOSED MAGNETOMETER
DETECTION LEGEND
W16-9P (24"X12")
W11-2 (30"X30")
AHEAD
W16-7P(R) (24"X12")
W16-7P(L) (24"X12")
SIGNS
R560-5 (18"X24")
TURNING
VEHICLES
FORSTOP
R10-15A(L) (30"X30")
STOP
R1-1
HIGH POINT RD (35 MPH)
HIGH POINT RD (35 MPH)
N
O
P
O S T E
D
S P E E
D
L I
M I T
F O
R E
L
F O
R E
L
N
O
P
O S T E
D
S P E E
D
L I
M I T
TURNING
VEHICLES
FORSTOP
R10-15A(R) (30"X30")
S1-1
SCHOOL
S4-3P
BE
PREPARED
TO STOP
(36"X36") W3-4
WITHIN
STOP
FOR
(12"X36") R1-6A
9"X12" R10-25 winnie.gobbel
GPLOT-V8
00T2305_27-0003.dgn
2:07:43 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
30 120
SCALE IN FEET
0 60
HIGH POINT RD @ FOREST HILLS DR
- R10-15A(R)
INSTALL ON EXISTING POST:
- R1-1
EXISTING:
- W16-9P
- W11-2
INSTALL:
- R10-15A(R)
INSTALL ON EXISTING POST:
- R1-1
EXISTING:
- R10-15A(L)
INSTALL ON EXISTING POST:
- R1-1
EXISTING:
- W16-9P
- W11-2
INSTALL:
INSTALL R560-5
INSTALL R560-5
- S4-3P
- S1-1
RELOCATE EXISTING:
IN 5" DIRECTIONAL BORE (50 LF)
INSTALL CONDUITS, NM, TP 3, 2-2" (100 LF)
INSTALL W3-4
INSTALL W3-4
INSTALL R1-6A
- TP 2 PULL BOX
- (2) W16-7P (24" X 12")
- (2) W11-2 (30" X 30")
AND MASTER CONTROLLER (SEE DETAIL ON SHEET 27-0004)
BEACON ASSEMBLY WITH PUSH BUTTON ACTIVATION, SIGN,
- GROUND MOUNTED AND DOUBLE-SIDED RECTANGULAR RAPID FLASHING
INSTALL:
LIGHTS
WARNING
TURN ON
BUTTON TO
PUSH
POWER POLE AND ROUTE TO CABINET
CONTRACTOR TO OBTAIN POWER SERVICE FROM EXISTING
INSTALL TP 2 PULL BOX
R1-6A
INSTALL
INSTALL CONDUITS, NM, TP 2, 2-2" (30 LF)
FROM POLE TO CABINET (SEE DETAIL 27-0005)
- CONDUIT, GRS, 1-2" (5 LF) FOR POWER SERVICE;
- PEDESTAL WITH POWER METER AND DISCONNECT UNIT
INSTALL:
PROPOSED SIGNAL DESIGN
5080 HIGH POINT ROAD
5080 HIGH POINT ROAD, SANDY SPRINGS, GA 30342
INSTALL CONDUIT, GRS, 1-1" (95 LF) FOR POWER SERVICE
PROJECT COST.
ALL COSTS TO BE INCIDENTAL TO THE OVERALL
PROVIDER TO TIE INTO THE EXISTING POWER SERVICE.
1. CONTRACTOR TO COORDINATE WITH POWER UTILITY
NOTE:
INSTALL TP 1 PULL BOX FOR POWER SERVICE
INSTALL TP 1 PULL BOX FOR POWER SERVICE
- IVDS CAMERA UNITS FOR PASSIVE PEDESTRIAN DETECTION
- LUMINAIRE ARM
- STEEL STRAIN POLE, TP IV, DECORATIVE
INSTALL:
INSTALL CONDUIT, GRS, 1-1" (15 LF) FOR POWER SERVICE
INSTALL TP 1 PULL BOX FOR POWER SERVICE
- TP 2 PULL BOX
- (2) W16-7P (24" X 12")
- (2) W11-2 (30" X 30")
WITH PUSH BUTTON ACTIVATION, SIGN, AND REMOTE CONTROLLER (SEE DETAIL ON SHEET 27-0004)
- GROUND MOUNTED AND DOUBLE-SIDED RECTANGULAR RAPID FLASHING BEACON ASSEMBLY
INSTALL:
POWER METER TO PULL BOX
- CONDUIT, GRS, 1-1" (5 LF) FOR POWER SERVICE; FROM
- TP 1 PULL BOX FOR POWER SERVICE
INSTALL:
PL
PL
PL
EXIST. R/W
EXIST. R/W
EXIST. R/W EXIST. R/W EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
E X I S
W
E X I S
27-0004 Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
PUSH
BUTTON
TO
CROSS
7’ MIN
13’
42"
MIN
1’-0"
LENGTH
OVERALL
VARIABLE
IVDS CAMERA UNIT
SPECIFIED ON PLANS
EVERY POLE UNLESS OTHERWISE
PULL BOX REQUIRED AT
PEDESTAL BASE
(DOUBLE-SIDED)
30"X30"
W11-2
(DOUBLE-SIDED)
24"X12" W16-7P
CONTROLLER CABINET
FLASHING BEACON
RECTANGULAR RAPID
POLE MOUNTED
9"X12" R10-25
POWER DISCONNECT BOX
(DOUBLE-SIDED)
FLASHING BEACONS
RECTANGULAR RAPID
CROSSWALK
TO FACE PEDESTRIAN
ORIENT PUSH BUTTON
13’
7’ MIN
42"
ENTRANCE CONDUITS PER SPECIFICATIONS
GROUND ROD PER SPECIFICATIONS
LUMINAIRE ARM
STEEL STRAIN POLE
TYPICAL EXAMPLE
AND STEEL STRAIN POLE
GROUND MOUNTED RECTANGULAR RAPID FLASHING BEACON
winnie.gobbel
GPLOT-V8
00T2305_27-0004.dgn
12:01:39 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
HIGH POINT RD @ FOREST HILLS DR
QUANTITIES
27-0005
SIGNAL PLAN
Peachtree Corners, Georgia 30092
Suite 350, 3930 East Jones Bridge Road
Engineering, Planning, and Environmental Consultants
REVISION DATES
12/8/2023 winnie.gobbel
GPLOT-V8
00T2305_27-0005.dgn
12:28:43 PM
GPLN4/28/2016
DRAWING No.
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
CHECKED:
PROJECT NUMBER
T2305
SANDY SPRINGS
GEORGIA
POWER METER SERVICE AND DISCONNECT
DETAIL
winnie.gobbel Image
BMP LOCATION DETAILS
54-0001
TEMPORARY GRASSING.
UPON GRADING COMPLETION IN LIEU OF
2. CONTRACTOR SHALL IMPLEMENT DS4 SODDING
PROJECT LIMITS PRIOR TO CONSTRUCTION
1. NO SUITABLE LOCATION FOR BMPS WITHIN
NOTES:
winnie.gobbel
GPLOT-V8
00T2305_54-0001.dgn
12:29:02 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
SCALE IN FEET
0 40 80
PROPERTY AND EXISTING R/W LINE
REQUIRED R/W LINE
EASEMENT FOR CONSTR
& MAINTENANCE OF SLOPES
EASEMENT FOR CONSTR
& MAINTENANCE OF DRAINAGE
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
PL CONSTRUCTION LIMITS
LIMIT OF ACCESS
REQ’D R/W & LIMIT OF ACCESS
ORANGE BARRIER FENCE
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
DROP INLETCATCH BASIN
OUTFLOW CONTROL DEVICE
JUNCTION BOXMANHOLE
C F
Peachtree Corners, Georgia 30092
3930 East Jones Bridge Road, Suite 350
Engineering, Planning, and Environmental Consultants
BMP LOCATION DETAILS
PEDESTRIAN CROSSING DESIGN
5080 HIGH POINT ROAD
5080 HIGH POINT ROAD, SANDY SPRINGS, GA 30342
P
HIGH POINT ROAD
F O
R E
L
F O
R E
L
D R I
V E
W A
Y B E T
H
T E F I L L
A H
E 2235587.2794
N 1416103.7443
STA. 101+00.00
BEGIN PROJECT T-2305
E 2235591.6289
N 1416603.7207
STA. 106+00.00
END PROJECT T-2305
STA. 101+27.23
BEGIN CONSTRUCTION
STA. 105+58.50
END CONSTRUCTION
PL
PL
PL
PL
PL
EXIST. R/W
EXIST. R/W
EXIST. R/W EXIST. R/W EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
E X I S
W
E X I S
W
EXIST. R/W
3 9
7 9
Ds4
Ds4
Ds4
EROSION CONTROL CONTRUCTION DETAILS
56-0001 winnie.gobbel
GPLOT-V8
00T2305_56-0001.dgn
12:29:07 PM
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
SANDY SPRINGS
GEORGIA
PROJECT NUMBER
T2305
SCALE IN FEET
0 40 80
PROPERTY AND EXISTING R/W LINE
REQUIRED R/W LINE
EASEMENT FOR CONSTR
& MAINTENANCE OF SLOPES
EASEMENT FOR CONSTR
& MAINTENANCE OF DRAINAGE
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
PL CONSTRUCTION LIMITS
LIMIT OF ACCESS
REQ’D R/W & LIMIT OF ACCESS
ORANGE BARRIER FENCE
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
DROP INLETCATCH BASIN
OUTFLOW CONTROL DEVICE
JUNCTION BOXMANHOLE
C F
Peachtree Corners, Georgia 30092
3930 East Jones Bridge Road, Suite 350
Engineering, Planning, and Environmental Consultants
PEDESTRIAN CROSSING DESIGN
File details come from the government source that posted it. Updated .