This document is an Addendum No. 2 to the 100% Construction Documents for the Downtown Bathrooms project issued by Architects: Lewis + Whitlock, P.A. on behalf of the City of Thomasville, Georgia. The addendum modifies the original construction drawings dated August 4, 2023, and includes revisions to the landscape plan, irrigation plan and details, and architectural site plans. The revisions address requested changes to the landscape, irrigation, and site elements such as the ramp section, brick screen wall, and plaza surface. No bid due date or award information is provided in this addendum.
The addendum includes revised drawings and specifications for various elements of the project, including LS1.0 Landscape Plan, IR1.0 Irrigation Plan, IR2.0 Irrigation Details, and AS1.1 Architectural Site Plans. The revisions focus on updating the landscape, irrigation, and site details to incorporate requested changes prior to the construction phase. Pricing terms, funding sources, incumbent contractors, or other salient commercial information are not included in this technical addendum.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2023_06_26 Downtown Bathroom Geotech Report.pdf | ||
| DowntownBathroomBidRejectionLetter (example).docx | DOCX document | |
| 2023_10_02 Addendum 1 (executed).pdf | ||
| 2023_09_05 Advertisement for Bids.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum NO. 2 100% Construction Documents
October 2, 2023
Project: Issued by:
Downtown Bathrooms Architects: Lewis + Whitlock, P.A.
206 W. Virginia Street Tallahassee, FL 32301 AL+W Project No. 22462 ph: 850.942.1718 fax: 850.942.2110
Distribution to:
OWNER REP: E. Geyer ARCHITECT: C. Whitlock
MPFP. ENGINEER: R. Gelhardt E ENGINEER: J. Lamb
This Addendum forms a part of the 100% Construction Documents and modifies the original Construction Drawings August 4th, 2023. Please attach this Addendum inside the front cover of the bound specifications and replace drawings and specifications as required. This Addendum consists of 2 pages and 6 attachments.
DRAWINGS:
Landscape
2-1 LS1.0 – Landscape Plan Replace sheet LS1.0 with Revised sheet LS1.0
• Revise landscape plan to show requested changes.
Irrigation
2-2 IR1.0 – Irrigation Plan Replace sheet IR1.0 with Revised sheet IR1.0
• Revise Irrigation plan to show requested changes.
2-3 IR2.0 – Irrigation Details Replace sheet IR2.0 with Revised sheet IR2.0
• Revise Irrigation plan to remove Hunter Pros-06 spray head detail.
Architectural
2-4 AS1.1 – Architectural Site Plans Replace sheet AS1.1 with Revised sheet AS1.1
• Revise 3/ Ramp Section to add edge protection rail.
• Revise Brick Screen Wall Elevation
Specifications
2-5 Section 042000 – Unit Masonry Revise sheet SP1.2 as follows.
• Modify Section 2.02-A.1: Basis of design as shown on attachment ADD 2-5.
2-6 Section 096700 – Fluid Applied Flooring Revise sheet SP1.6 as follows.
• Modify Section 2.01-A.6: Products as shown on attachment ADD 2-6.
Addendum No. 2 Thomasville Downtown Bathroom October 2, 2023
Attachments
2 - 8 1/2" x 11" pages: ADD 2-5 and ADD 2-6 4 - 24" x 36" sheets: LS1.0, IR1.0, IR2.0, and AS1.1
BY: Architects: Lewis + Whitlock, PA
B. Baylor bbaylor New Stamp
ID
RE
VI
SI
ON
DR
AW
N:
RE
VI
EW
ED
DA
TE
1 2 Ad de nd um #1
Ad de nd um
#2 B.
B.
B.
B.
C.
W
HI
TL
OC
K C.
W
HI
TL
OC
K 9/2
0/2
/02 /20
TH
ES
E
DR
AW
IN
GS
A
ND
R
EN
DE
RI
NG
S
AR
E
IN
ST
RU
ME
NT
S
OF
S
ER
VI
CE
. T
HE
D
RA
W
IN
GS
A
ND
A
SS
OC
IA
TE
D
CO
PI
ES
T
HE
RE
OF
, I
NC
LU
DI
NG
E
LE
CT
RO
NI
C
ME
DI
A
AN
D
CA
DD
F
ILE
S, A
RE
T
HE
P
RO
PE
RT
Y
OF
A
RC
HI
TE
CT
S:
LE
W
IS
W
HI
TL
OC
K, P A.
A.
T
HE
IR
U
SE
, R
EP
RE
SE
NT
AT
IO
N
OR
R
EP
RO
DU
CT
IO
N
FO
R
AN
Y
PU
RP
OS
E
EX
CE
PT
B
Y W
RI
TT
EN
A
GR
EE
ME
NT
W
IT
H
TH
E
AR
CH
IT
EC
T
IS
P
RO
HI
BI
TE
D.
T
HI
S
CO
PY
RI
GH
T
NO
TI
FI
CA
TI
ON
S
HA
LL
B E
TR
UE
A S
IF
D
IR
EC
TL
Y
PL
AC
ED
O
N
EA
CH
D
RA
W
IN
G
EX
HI
BI
T
OR
R
EN
DE
RI
NG
O N
TH
IS
D
OC
UM
EN
T
AN
D
SH
AL
L N
OT
B
E
RE
MO
VE
D
FR
OM
T
HE
SE
D
OC
UM
EN
TS
Sheet No.:
AS1.1
PH
AS
E:
CO
NC
EP
T
SC
HE
M.
D
ES
IG
N
AD
VA
NC
ED
S
CH
EM
. D
ES
IG
N
C
ON
ST
RU
CT
IO
N
DO
CS
C
ON
ST
RU
CT
IO
N
DO
CS
PE
RM
IT
D
OC
S.
0%
C
ON
ST
RU
CT
IO
N
DO
CS
DR
AW
N:
DA
TE
C on su lta nt
Description:
Architectural Site Plan
Jo b
Ti tle
D ow nt ow n Ba th ro om s
Pr oj ec t #
Ph as e:
0%
C on st ru ct io n D oc um en ts
C lie nt
C ity o f T ho m as vi lle
R em in gt on
A ve
, T ho m as vi lle
, G eo rg ia
Se al
B
IM
cl ou d:
L ew is
-B
IM
B
IM
cl ou d
B as ic fo r A rc hi ca d
/2
Th om as vi lle R es tr oo m s
C
D 7:
A
M
Architects Lewis + Whitlock 206 West Virginia St.
Tallahassee, Florida 32301 850,942.1718 www.think3d.net
RE
VI
EW
ED
AT
C.
W
HI
TL
OC
K
/14 /23
AT
/ B
B C.
W
HI
TL
OC
K
/04 /23
SLOPING SIDEWALK
MAX SLOPE - 1:20
'-1
1/ 8"
'-3
'-4
2'- 6"
1'- 0"
2 1/4" (+/-) 10'-10" 38'-8" 13'-6" 5'-0"
6'- 0"
TY
P.
S
PA
CI
NG
3'- 1"
8'- 8"
1'- 0"
'-4
'-8
4'- 5"
4'- 0"
- 2
2'- 8"
3'-6" 25'-4" 3'-6"
5'- 7"
3'- 9"
4'- 0"
4'- 0"
4" 5'-
4" 4"
279.95
279.82 279.98279.94
281.27281.27
282.38
280.00
282.50
279.86
AS1.1
AS1.1
2'-0" HIGH BRICK
SCREEN WALL
6'-0" HIGH METAL FENCING W/ GATE
6'-0 HIGH METAL FENCING
TIE IN TO SIDEWALK TO
MUNICIPAL PARKING
TIE IN TO EX. SIDEWALK
TIE IN TO EX. SIDEWALK
NEW UTILITY POLE, BY CITY.
PEDESTAL MOUNTED -
ELECTRICAL SERVICE,
COOR. W/ ELEC DWGS
TIE IN TO EX.
LANDSCAPING &
CURB
SINGLE BRICK BANDING (P1) AT
CONC. SIDEWALK
PROVIDE CONTINUATION OF EX.
RETAINING WALL TO EDGE OF ADJ.
BUILDING WHERE SIDEWALK WAS
REMOVED
SURFACE DRAIN, SEE CIVIL DWGS
SIDEWALK
CONSTRUCTED BY
OTHER CITY PROJECT -
COOR. W/ GC FOR
CONNECTION
PROVIDE SLOPE OUT OF
CORNER TO ALLOW
DRAINAGE TO LANDSCAPING
PROPERTY
LINE
SL
OP
IN
G
SI
DE
W
AL
K
MA
X
SL
OP
E
- 1 :20
LA
ND
SC
AP
IN
G
SL
OP
E
TO
E X.
SE
RV
IC
E
DR
IV
E
LANDSCAPING
LANDSCAPING
LANDSCAPING
LA
ND
SC
AP
IN
G
UTILITY AREA
(CONCRETE SURFACE)
RA
MP
MA
X
SL
OP
E
- 1
:12
RA
MP
MA
X
SL
OP
E
- 1
:12
SLOPE TO DRAIN
(CROSS SLOPE TO NOT EXCEED 2%)
C
J
C
J
C
J
E
J
E
J
C
J
E
J
E J
CONCRETE
UP
UP
E J
C J
E J
C J
C J
E J
E J
CONCRETE PLAZA
W/ DOUBLE BRICK
BANDING (P2)
T J T J
T
J
T J T
J
TYP.
T J T J T J T J
SLOPE
- 1
'-3
3'- 0"
2" 4'-
0" 2"
4'- 7"
5'-0" 10" 5'-0"
2'- 5"
2'- 7"
3'-8"3'-8" 31'-4"
5 1/4" 4 3/4"
279.74
280.04 280.03 279.84
281.20281.28
AS1.1
SLOPING SITE WALL, 6" ABOVE
GRADE OF ADJACENT
SIDEWALK/ UPPER GRADE
2'-0" HIGH BRICK
SCREEN WALL
2'-0" HIGH BRICK
SCREEN WALL
CITY OF THOMASVILLE STANDARD
BENCH - OWNER PROVIDED,
CONTRACTOR INSTALLED (TYP. OF 2)
2'-0" HIGH BRICK
SCREEN WALL
ALTERNATE: PLAZA SURFACE & SCREEN WALLS
BRICK SCREEN WALLS AND BRICK PAVERS TO BE PRICED AS AN
ALTERNATE.
BASE BID: GROUND SURFACE IS 4" CONCRETE SLAB W/ LIGHT BROOM
FINISH, CONTROL JOINTS TO BE UTILIZED TO CREATE OUTSIDE BANDING
3'-0" HIGH STUCCOED
CMU WALL
PERFORATED
METAL PANEL
GUARDRAIL
DOWNTOWN RESTROOMS
105 REMINGTON AVE
FFE: 280.08
6" T
YP
3'-0 1/2"
3'- 0"
1-1/2" CONT. HANDRAIL
AT 36" AFF, TYP.
#4 BAR AT NOSING -
TYPICAL ALL RISERS
3/8" COMPRESSIBLE
JOINT FILLER - TYP.
MIN. 4" CLEAN,
COMPACTED FILL BELOW
CONCRETE, TYP. #5 BAR CONT.
4" THICK 3000 PSI
CONCRETE WITH
6X6 (W2.9/W2.9)
WWF
4 MIL POLYETHYLENE
VAPOR BARRIER
SUBGRADE, 95%
COMPACTED
3/8" COMPRESSIBLE
JOINT FILLER - TYP.
1'-0" 11" 11" 11" 11"
8"
4"
8"
4"
P1 - SINGLE
HEADER BRICK
PAVING
P2 - DOUBLE
HEADER BRICK
PAVING
5" 4'-2 1/2" 5"
VARIES, EDGE OF SLAB
EXTENDS TO EX. RETAINING WALL
5'-0"
5" 4'-2 1/2" 5"
5'-0"
4" T
YP
2'- 8"
T
YP
3'-
0" T
YP
DIRECT APPLIED STUCCO FINISH,
SEE PRODUCT INFO, SHEET A2.1
CONCRETE STEM WALL, SEE
STRUC. DWGS
1 1/2" DIA. HANDRAIL, SEE SPECS.
1 1/2" DIA RAIL - SEE WEST
ELEVATION FOR LOCATION
CORE DRILL TO PROVIDE 4"
IMBED - PROVIDE NON-SHRINK
GROUT AND SLOPE UP TO POLE
EXISTING CONC.
RETAINING WALL
3/8" JOINT FILLER, RECESS 1/4"
BELOW CONC, TYP.
FOUNDATION, SEE STRUCT.
DWGS.
MIN. 4" CLEAN, COMPACTED
FILL BELOW FOOTING, TYP.
PROVIDE SLOPED SURFACE AT
TOP OF STUCCOED WALL TO
DRAIN WATER (SLOPE BOTH
DIRECTIONS)
1 1/2" DIA RAIL POST
2'-6"
UPPER LANDING
PAVER, TYP. (SEE NOTES)
1 1/2"- 2" SAND SETTING BED
1/2" COMPRESSIBLE JOINT
FILLER, TYP. EA SIDE
4" 3000 PSI CONCRETE
#4 X 4" REBAR DOWEL AT 18" O.C.
MIN. 4" CLEAN, COMPACTED FILL
BELOW CONCRETE, TYP.
SUBGRADE, 95% COMPACTED
PAVER, TYP. (SEE NOTES)
1 1/2"- 2" SAND SETTING BED
CONCRETE EDGE RESTRAINT
(CONCEALED FROM VIEW) WHERE
PAVER BANDS TERMINATE INTO
PLANTING AREA
PLANTING AREA
4" 3000 PSI CONCRETE
#4 X 4" REBAR DOWEL AT 18" O.C.
MIN. 4" CLEAN, COMPACTED FILL
BELOW CONCRETE, TYP.
SUBGRADE, 95% COMPACTED
1/2" COMPRESSIBLE JOINT FILLER
LINE OF VERTICAL
SUPPORT, TYP.
MASONRY, AS
SPECIFIED.
MASONRY CAP
2'- 1"
7 5/8"
13/16" 6" 13/16"
1'- 0"
1'-6"
BRICK CAP
OPENING - FACE OF BRICK
BEYOND SHOWN
STRETCHER COURSE
FLASHING
8" M
IN
#4 VERTICAL AT 32" OC
#4 CONTINUOUS
(2) #4 CONT W/ #3 TIES @ 24" OC
CONCRETE FOOTING
MIN. 4" CLEAN, COMPACTED FILL
BELOW FOOTING, TYP.
NN
1/4" = 1'-0"1 Architectural Site Plan
1" = 1'-0"2 Stair Section
1" = 1'-0"4 Paver Patterns
1" = 1'-0"3 Ramp Section
1" = 1'-0"5 Paver Detail - Building Edge
1" = 1'-0"6 Paver Detail - Building Edge
1" = 1'-0"7 Brick Screen Wall Elevation
1" = 1'-0"8 Brick Screen Wall Section
TRUE
NORTH
PLAN
NORTH
GRADING NOTE:
SEE CIVIL DRAWINGS FOR GRADING PLAN. GRADE
ELEVATIONS SHOWN THIS PLAN FOR REFERENCE ONLY.
PAVER NOTES:
1. PAVERS TO BE: PAVESTONE HOLLAND 6 CM; SIZE: 4"X8", COLOR:
CHARCOAL
2. PAVERS SHALL BE PLACED HANDTIGHT WITH SAND SWEPT JOINTS
3. WHERE VOIDS BETWEEN PAVER BAND AND BUILDING WALL EXIST,
PROVIDE 1/2" COMPRESSIBLE JOINT FILLER.
CONCRETE JOINT NOTES:
TJ = TOOLED JOINT
CJ = CONTROL JOINT - 1/4" DEEP SAW CUT JOINT
EJ = EXPANSION JOINT - 3/8" COMPRESSIBLE JOINT FILLER
Thomasville | Downtown Bathrooms
22462 Unit Masonry 042000 -2
S. BIA Technical Notes No. 13 - Ceramic Glazed Brick Exterior Walls 2017.
T. BIA Technical Notes No. 28B - Brick Veneer/Steel Stud Walls 2005.
U. BIA Technical Notes No. 46 - Maintenance of Brick Masonry 2017.
V. TMS 402/602 - Building Code Requirements and Specification for Masonry Structures 2016.
1.04 SUBMITTALS
A. See Section 013000 - Administrative Requirements for submittal procedures.
B. Product Data: Provide data for masonry units, fabricated wire reinforcement, mortar, and masonry accessories.
C. Samples: Submit two samples of decorative block units to illustrate color, texture, and extremes of color range.
D. Submit manufacturer's full color range for Architect selection.
1.05 QUALITY ASSURANCE
A. Comply with provisions of TMS 402/602, except where exceeded by requirements of Contract Documents.
B. Manufacturer Qualifications: Company specializing in manufacturing the type of products specified in this section with minimum 10 years of documented experience.
1.06 MOCK-UPS
A. Construct a masonry wall as a mock-up panel sized 8 feet (2.4 m) long by 6 feet (1.8 m) high;
include mortar, accessories, structural backup, and flashings (with lap joint, corner, and end dam) in mock-up.
B. Locate where directed.
C. Mock-up may remain as part of work.
1.07 DELIVERY, STORAGE, AND HANDLING
A. Deliver, handle, and store masonry units by means that will prevent mechanical damage and contamination by other materials.
PART 2 PRODUCTS
2.01 CONCRETE MASONRY UNITS
A. Concrete Block: Comply with referenced standards and as follows:
1. Size: Standard units with nominal face dimensions of 16 by 8 inches (400 by 200 mm) and nominal depths as indicated on drawings for specific locations.
2. Load-Bearing Units: ASTM C90, normal weight.
a. Hollow block, as indicated.
b. Exposed Faces: Manufacturer's standard color and texture where indicated.
2.02 BRICK UNITS
A. Facing Brick: ASTM C216, Type FBS Smooth, Grade SW.
1. Basis of design:
a. Manufacturer: Cherokee Brick, Macon Plant
b. Color and texture: Kennesaw, heritage texture .
2. Queen Modular size: As indicated on drawings .
3. Bond pattern: common bond.
4. Special shapes: Molded units as required by conditions indicated, unless standard units can be sawn to produce equivalent effect.
a. Provide solid brick at locations where brick cores would otherwise be visible.
2.03 MORTAR AND GROUT MATERIALS
A. Portland Cement: ASTM C150/C150M, Type I; color as required to produce approved color sample.
B. Hydrated Lime: ASTM C207, Type S.
cwhitlock Polygon cwhitlock Polygon cwhitlock Typewritten Text cwhitlock Typewritten Text Attachment Add 2-5
Thomasville | Downtown Bathrooms
22462 Fluid-Applied Flooring 096700 -2
4. Color: as indicated on drawings .
5. Base - 6" high integral resinous.
6. Products:
a. Key Resin Company ; Key Quartz B-125 : www.keyresin.com/#sle.
b. Stonhard; Stonshield SLT: www.stonhard.com/#sle.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that subfloor surfaces are smooth and flat within the tolerances specified for that type of work and are ready to receive flooring.
B. Verify that subfloor surfaces are dust-free and free of substances that could impair bonding of materials to subfloor surfaces.
C. Cementitious Subfloor Surfaces: Verify that substrates are ready for fluid-applied flooring installation by testing for moisture and alkalinity (pH).
1. Obtain instructions if test results are not within limits recommended by fluid-applied flooring manufacturer.
3.02 PREPARATION
A. Remove subfloor ridges and bumps. Fill low spots, cracks, joints, holes, and other defects with subfloor filler.
B. Apply, trowel, and float filler to achieve smooth, flat, hard surface. Grind irregularities above the surface level. Prohibit traffic until filler is cured.
C. Vacuum clean substrate.
D. Apply primer to surfaces required by flooring manufacturer.
3.03 INSTALLATION - FLOORING
A. Apply in accordance with manufacturer's instructions.
B. Apply each coat to minimum thickness required by manufacturer.
C. Finish to smooth level surface.
3.04 FIELD QUALITY CONTROL
A. See Section 014000 - Quality Requirements, for additional requirements.
3.05 PROTECTION
A. Prohibit traffic on floor finish for 48 hours after installation.
B. Barricade area to protect flooring until fully cured.
END OF SECTION
cwhitlock Polygon cwhitlock Polygon cwhitlock Typewritten Text cwhitlock Typewritten Text Attachment Add 2-6
RE
M
IN
G
TO
N
A
VE
N
UE
1 inch = ft.
GRAPHIC SCALE
2 84
PROPOSED DOWNTOWN RESTROOMS
105 REMINGTON AVENUE
(SEE ARCHITECTURAL PLANS)
PROPOSED WALL
(SEE ARCHITECTURAL PLANS)
PROPOSED HARD SURFACE / PLAZA
(SEE ARCHITECTURAL PLANS)
PR
O
PO
SE
D R
AM
P
(S
EE
A
RC
H
ITE
C
TU
RA
L
PL
AN
S)
PR
O
PO
SE
D R
AM
P
(S
EE
A
RC
H
ITE
C
TU
RA
L
PL
AN
S)
PROPOSED WALL
(SEE ARCHITECTURAL PLANS)
PROPOSED ROOF OVERHANG
(SEE ARCHITECTURAL PLANS)
SITE BOUNDARY (TYP.)
PROPOSED HARDSCAPE / PLAZA
(SEE ARCHITECTURAL PLANS)
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
PROPOSED WALL
(SEE ARCHITECTURAL PLANS)
PROPOSED WALL
(SEE ARCHITECTURAL PLANS)
EXISTING
CONCRETE
EXISTING
CONCRETE
EXISTING
CONCRETE
EXISTING
CONCRETE
PROPOSED SURFACE DRAINS
(SEE CIVIL PLANS)PROPOSED FENCE
(SEE ARCHITECTURAL PLANS)
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
EXISTING OVERHEAD UTILITY
(APPROXIMATE LOCATION)
EXISTING
LANDSCAPING
AREA
IRRIGATION NOTES:
1. IRRIGATION SYSTEM DESIGN REQUIREMENTS: MIN. 25 GPM @ 50 PSI @ THE WATER
SOURCE.
2. VALVE NUMBERS INDICATE CONTROLLER STATION TO WHICH THAT VALVE IS TO BE
CONNECTED.
3. AUTOMATIC ELECTRIC VALVES AND ISOLATION VALVES ARE TO BE INSTALLED IN
RECTANGULAR VALVE BOXES PER DETAIL OR AS APPROVED.
4. WIRE CONNECTIONS TO THE ELECTRIC VALVES ARE TO BE MADE WITH WATERPROOF
WIRE CONNECTORS.
5. ELECTRICAL WIRE IS TO BE TYPED UF 600 VOLT AWG - CONTROL CABLE, COMMON OR
'GROUND' WIRE IS TO BE #14 OR LARGER AND WHITE IN COLOR. CONTROL OF 'HOT'
WIRE IS TO BE #14 OR LARGER AND ANY COLOR OTHER THAN WHITE.
6. ALL VALVE WIRES SHALL BE TAPED AT 20' INTERVALS AND LOCATED UNDER IRRIGATION
MAINLINE OR AS SHOWN ON DETAIL.
7. POP-UPS ARE TO BE INSTALLED ON FLEX TUBING OR AS SHOWN ON DETAIL.
8. SPRAY NOZZLES, INSTALLED IN SHRUB OR FLOWER BEDS, MAY REQUIRE EXTENSIONS FOR
SUFFICIENT HEIGHT TO PREVENT INTERRUPTION OF THE STREAM BY THE PLANT MATERIAL.
9. PIPING MAY SOMETIMES BE INDICATED AS BEING LOCATED IN UNLIKELY AREAS; I.E., IN
BUILDINGS, UNDER PAVEMENT, OUTSIDE OF PROPERTY LINES, ETC... THIS IS DONE FOR
GRAPHIC CLARITY ONLY. WHENEVER POSSIBLE, PIPING IS TO BE INSTALLED IN SOIL
AREAS.
10. MAINLINE IS TO BE INSTALLED A MINIMUM OF 18" BELOW FINISH GRADE. LATERAL LINES
ARE TO BE INSTALLED A MINIMUM OF 14" BELOW FINISH GRADE.
11. UNLESS OTHERWISE INDICATED, ALL SLEEVES ARE TO BE PVC SCH 40 AND TWO (2) SIZES
LARGER THAN THE PIPE TO BE SLEEVED. FOR EXAMPLE: THE SLEEVE FOR A 1" PIPE SHALL
BE 1-1/2" PVC SCH 40. NO IRRIGATION SLEEVE SHALL BE SMALLER THAN 1-1/2".
12. ALL IRRIGATION MAINLINES SHALL BE PVC SCH 40 UNLESS OTHERWISE NOTED.
13. ALL IRRIGATION LATERALS SHALL BE PVC SCH 40 UNLESS OTHERWISE NOTED.
14. EXACT CONTROLLER LOCATION SHALL BE DETERMINED IN THE FIELD AT THE TIME OF
INSTALLATION AND APPROVED BY THE LANDSCAPE ARCHITECT.
15. LIGHTNING PROTECTION SHALL BE INSTALLED ON EACH CONTROLLER: A 5/8" x 8'
COPPER CLAD LIGHTNING GROUND ROD W/5 OHMS OR LESS RESISTANCE TO EARTH
AND CONNECTED TO THE CONTROLLER.
16. THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR BRINGING ELECTRICAL
POWER TO THE CONTROLLER LOCATION.
17. WHERE APPLICABLE, MAINLINE AND LATERAL SHALL BE PLACED IN SAME TRENCH OR AS
SHOWN ON DETAIL.
18. ALL IRRIGATION HEADS SHALL BE A MINIMUM OF 12" FROM BUILDINGS AND WALLS. ALL
IRRIGATION HEADS SHALL BE A MINIMUM OF 6" FROM PAVEMENT EDGES.
19. THE IRRIGATION CONTRACTOR MAY HAVE TO MAKE FIELD ADJUSTMENTS. ANY
SUBSTANTIAL DEVIATIONS TO THE PLAN SHALL REQUIRE THE IRRIGATION CONTRACTOR
TO PROVIDE AS-BUILT DRAWING(S) OF THE CONSTRUCTED SYSTEM.
-WATERING SCHEDULE-
ZONE GPM
TIME/DAY
30 MIN.
20 MIN.
DAYS/WEEK
PROGRAM
BED
LAWN
WEEK #1
WEEK #2
WEEK #3
WEEK #4
DAYS/WEEK (AT INITIAL PLANTING)
NOTE:
IRRIGATION PIPING LOCATIONS MAY BE DRAWN FOR
GRAPHIC CLARITY ONLY. WHENEVER POSSIBLE, PIPING
IS TO BE INSTALLED IN SOIL AREAS & MAINLINE AND
LATERAL LINES SHALL BE PLACED IN SAME TRENCH.
PLACE IRRIGATION PIPING ALONG THE EDGE OF
PAVEMENT IF POSSIBLE AND MINIMIZE TRENCHING
UNDER EXISTING TREES.
1" IRRIGATION BACKFLOW PREVENTER
BURIED IRRIGATION LINE (PVC SCH 40)
RAIN SENSOR: HUNTER MINI-CLIK
1" ELECTRIC VALVE: HUNTER PGV 101
4 STATIONS CONTROLLER: HUNTER PRO-C PC-400
1" IRRIGATION METERM
SCH 40 SLEEVE
SCH 40 MAINLINE
C
RS
PROPOSED IRRIGATION ZONE
ZONE NUMBER
VALVE SIZEGPM
12" POP-UP
12" POP-UP
12" POP-UP
5' X 15' 5' X 30'
0.22
0.44
0.22 40
PROS - 12 - PRS40 - CV - MPLCS515
PROS - 12 - PRS40 - CV - MPRCS515
PROS - 12 - PRS40 - CV - MPSS530
5' X 15'40
PCB-10 18" BUBBLER1.00 40 3'
IRRIGATION SCHEDULE
SYMBOL GPMMANF. NUMBER REMARKSPSI RAD.
HUNTER MP ROTATOR
BUBBLER
OTHER
4"
CONST. 1 12" SLEEVE TO
CONTROLLER FOR ELECTRICAL
WIRES FROM VALVES
CONST. SLEEVE TWO (2) SIZES LARGER
THAN THE PIPE TO BE SLEEVED AND
NO SMALLER THAN 1 12" (TYP.)
APPROXIMATE LOCATION OF
IRRIGATION CONTROLLER AND
RAIN SENSOR. IRRIGATION
CONTRACTOR SHALL COORDINATE
EXACT LOCATION WITH GENERAL
CONTRACTOR. INSTALL RAIN
SENSOR IN AN OPEN (UNCOVERED)
LOCATION.
12" POP-UP2' X 10'0.42 40PROS - 12 - PRS40 - CV - 5-CST-B
C RS
M
CONST. 1" WATER METER AND BACKFLOW
PREVENTER FOR IRRIGATION SYSTEM PER
DETAIL (OR CITY SPECIFICATIONS) IRRIGATION SERVICE POINT OF
CONNECTION (TBD)
CONST. 1 12" SCH 40
MAINLINE (TYP.)
4"
4"
4"
4"
4"
4"
4"
4"
4"
1"
1"
1"
CONST. 1 12" SLEEVE
TO CONTROLLER FOR
ELECTRICAL WIRES
FROM VALVES
4"3
4"
SHEET
SH
EE
T
TIT
LE
PR
O
JE
C T
N
AM
E
C
LI
EN
T
N
AM
E
RE
VI
SI
O
N S
DATE:
DRAWN BY:
COWLES LANDSCAPE ARCHITECTURE
(CLA)
2285 TRESCOTT DRIVE
TALLAHASSEE, FL 32308
(850) 545-7035 www.cowlesLA.com
D a vi d
L . C o w le s, J r., R .L
.A
Fl o rid a
R e g . N o : L
A6 w w w .C
O W
LE
SL
A.
c o m
0)
-7
T
AL
LA
H
AS
SE
E, F
L
IR1.0
IR
RI
G A
TI
O
N P
LA
N
D O
W N
TO
W
N B
A
TH
RO
O
M S
RE
M
IN
G
TO
N
A
VE
N
UE
C
IT
Y O
F
TH
O M
A
SV
IL
LE
TH
O
M A
SV
IL
LE
, G
EO
RG
IA
9/29/2023
DLC
IRRIGATION SPECIFICATIONS
1. GENERAL/PRODUCTS
1.1. SYSTEM SHALL CONFORM TO ALL LOCAL CROSS-CONNECTIONS, PLUMBING AND
ELECTRICAL CODES.
1.2. ALL MATERIALS TO BE INCORPORATED IN THIS SYSTEM SHALL BE NEW AND WITHOUT FLAWS OR
DEFECTS. ALL PIPE DAMAGED OR REJECTED BECAUSE OF DEFECTS SHALL BE REMOVED,
WITH EXCEPTION TO RELOCATED MATERIAL, FROM THE SITE AT THE TIME OF REJECTION.
1.3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSURE AND GUARANTEE COMPLETE 100%
COVERAGE OF THE AREAS SHOWN ON THE DRAWINGS TO BE IRRIGATED. HE SHALL ALSO
GUARANTEE THE SATISFACTORY OPERATION OF THE ENTIRE SYSTEM AND THE RESTORATION OF
THE SITE PRIOR TO WORK.
1.4. THE ENTIRE SYSTEM SHALL BE GUARANTEED TO BE COMPLETE AND FULLY OPERATIONAL FOR
THE PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. CONTRACTOR SHALL REPAIR
OR REPLACE ANY DEFECTS OCCURRING WITHIN THAT YEAR, FREE OF EXPENSE TO THE
OWNER.
1.5. AFTER FINAL ACCEPTANCE OF THE COMPLETED INSTALLATION, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR HAVING COMPLETE REPRODUCIBLE DRAWINGS PREPARED AND SHOWING
ALL CHANGES. THESE DRAWINGS SHALL BE TURNED OVER TO THE OWNER.
1.6. PLASTIC PIPE LINE SHALL BE RIGID UN-PLASTICIZED, BELL END, PVC TYPE (1102,2120, ETC), SCHEDULE 40 PVC (ASTM-1785).
1.7. ALL PLASTIC PIPE FITTINGS SHALL BE SCHEDULE 40 PVC (ASTM D-2466) MOLDED FITTINGS
MANUFACTURED OF THE SAME MATERIAL AS THE PIPE.
2. AS-BUILTS
2.1. STATIC PRESSURE OF THE WATER SOURCE SHALL BE MEASURED AND NOTED ON THE SHOP
DRAWINGS.
2.2. THE PRESSURE LOSS THROUGH THE SYSTEM SHALL BE INCLUDED AS PART OF THE SHOP
DRAWINGS.
2.3. THE MAXIMUM AND MINIMUM PRESSURE AT THE BASE OF THE CLOSEST AND FURTHEST
SPRINKLER SHALL BE INDICATED ON THE SHOP DRAWING.
2.4. ADEQUATE PRESSURE RELIEF, SURGE PROTECTION, THRUST RESTRAINT, AND AIR RELIEF VALVES
SHALL BE USED FOR ALL PIPING.
3. HYDROSTATIC TESTS
3.1. TESTING OF THE INSTALLED SYSTEM SHALL BE REQUESTED OF THE CONTRACTOR BY THE
OWNER IN WRITING AT LEAST 48 HOURS IN ADVANCE OF THE TEST.
3.2. TESTING SHALL BE ACCOMPLISHED AT THE EXPENSE OF THE CONTRACTOR AND IN THE
PRESENCE OF THE OWNER.
3.3. WHEN TESTING WITH OPEN TRENCHES, CENTER LOAD PIPING WITH SMALL AMOUNT OF
BACKFILL TO PREVENT ARCHING OR SLIPPING UNDER PRESSURE.
3.4. MAIN LINES AND SUB-MAINS SHALL BE TESTED FOR TWO HOURS AND LATERAL LINES FOR ONE
HOUR.
3.5. IF LINES OR FITTINGS DO NOT HOLD OR MORE THAN 5 PSI IS LOST DURING TESTING, THE
CONTRACTOR MUST MAKE CORRECTIONS AND RESCHEDULE TESTING.
4. EXECUTION
4.1. ALL PRESSURIZED PLASTIC AND GALVANIZED PIPE, SPRINKLER LINES OR MAINS SHALL BE
INSTALLED WITH A MINIMUM COVER OF 18 INCHES BASED ON FINISHED GRADES.
NON-PRESSURIZED LINES SHALL BE INSTALLED WITH A MINIMUM COVER OF 12" BASED ON
FINISHED GRADE.
4.2. DEPTH OF SLEEVES UNDER ASPHALT OR CONCRETE SHALL BE 24", EXCEPT 30" FOR 6" AND
LARGER PIPES, WHERE ANY CUTTING OR BREAKING OF SIDEWALKS, CONCRETE WORK
AND/OR ASPHALT IS NECESSARY, IT SHALL BE REMOVED AND REPLACED BY THE
CONTRACTOR. PERMISSION TO CUT OR BREAK SIDEWALKS, CONCRETE AND/OR ASPHALT
SHALL BE OBTAINED FROM THOSE HAVING PROPER JURISDICTION.
4.3. PIPE USED ABOVE GROUND WITH BACKFLOW PREVENTION DEVICES OR PUMPING STATIONS
SHALL BE SCHEDULED 40 GALVANIZED STEEL (ASTM A-120/A-53) AND JOINTED WITH 150
POUND TESTED GALVANIZED MALLEABLE IRON PIPE FITTINGS (ASTM A-338). PIPE OF THE
ABOVE TYPE SHALL BE ANCHORED WITH ONE CUBIC FOOT OF CONCRETE.
4.4. THE BACKFILL SHALL BE THOROUGHLY COMPACTED AND EVENED OFF WITH THE ADJACENT
SOIL LEVEL. BACKFILL SHALL CONTAIN NO LUMPS OR ROCKS LARGER THAN 2 1/2".
4.5. TRENCHES SHALL BE OPENED AND BACKFILLED ON THE SAME DAY.
4.6. PLASTIC PIPE SHALL BE INSTALLED ACCORDING TO ASTM D-2855, ASAES-376, AND SCS
430-DD-1. PIPE SHALL BE INSTALLED AS RECOMMENDED BY THE MANUFACTURER TO ALLOW
FOR EXPANSION, CONTRACTION AND SNAKING.
4.7. PLASTIC PIPE SHALL BE CUT WITH A HACK SAW WITH THE ASSISTANCE OF A SQUARE SAWING
DEVICE, OR IN A MANNER TO ENSURE A SQUARE CUT. BURRS AT CUT ENDS SHALL BE
REMOVED PRIOR TO INSTALLATION TO PROVIDE A SMOOTH UNOBSTRUCTED FLOW.
4.8. ALL PLASTIC TO PLASTIC JOINTS SHALL BE SOLVENT WELD JOINTS OR SLIP SEAL JOINTS. ONLY
THE SOLVENT RECOMMENDED BY THE PIPE MANUFACTURER (ASTMD-2564) SHALL BE USED.
ALL FLEX PIPE SWING JOINTS SHALL BE CEMENTED WITH IPS #795, OR EQUAL. ALL PLASTIC PIPE AND FITTINGS SHALL BE CLEANED WITH APPROPRIATE PVC CLEANER (ASTM F-656), AND
INSTALLED AS OUTLINED AND INSTRUCTED BY THE PIPE MANUFACTURER. NO GLUE SHALL BE
LEFT INSIDE THE PIPE.
4.9. THE SOLVENT WELD JOINTS SHALL BE MADE IN THE FOLLOWING MANNER:
4.9.1. THOROUGHLY CLEAN THE MATING PIPE AND FITTING WITH A CLEAN DRY CLOTH.
4.9.2. APPLY A UNIFORM COAT OF SOLVENT TO THE PIPE WITH AN APPROVED APPLICATOR.
4.9.3. APPLY SOLVENT TO FITTING IN A SIMILAR MANNER.
4.9.4. REAPPLY A LIGHT COAT OF SOLVENT TO THE PIPE AND IMMEDIATELY INSERT INTO THE
FITTING.
4.9.5. TURN THE PIPE OR FITTING ONE QUARTER TO INSURE EVEN DISTRIBUTION IN THE SOCKET.
INSERT PIPE TO THE FULL DEPTH OF THE FITTING SOCKET.
4.9.6. WIPE OFF ANY EXCESS SOLVENT THAT APPEARS AT THE OUTER SHOULDER OF THE FITTING.
DO NOT USE AN EXCESSIVE AMOUNT OF SOLVENT SO AS TO AVOID ANY OBSTRUCTION
TO FORM ON THE PIPE. ALLOW JOINTS TO SET A MINIMUM OF 24 HOURS BEFORE
PRESSURE IS APPLIED TO THE SYSTEM.
4.10. ALL OPENINGS SHALL BE CAPPED OR PLUGGED FOLLOWING THE INSTALLATION OF LINES TO
PREVENT THE ENTRANCE OF MATERIALS THAT WOULD OBSTRUCT THE PIPE OR SPRINKLERS.
LEAVE PLUG OR CAP IN PLACE UNTIL REMOVAL IS NECESSARY FOR COMPLETION OF
INSTALLATION.
4.11. THOROUGHLY FLUSH OUT ALL WATER LINES BEFORE INSTALLING HEADS, VALVES, AND OTHER
HYDRANTS.
4.12. UPON COMPLETION OF THE FLUSHING, THE CONTRACTOR SHALL RECAP THE LINES FOR
PRESSURE TESTING..
SHEET
SH
EE
T
TIT
LE
PR
O
JE
C T
N
AM
E
C
LI
EN
T
N
AM
E
RE
VI
SI
O
N S
DATE:
DRAWN BY:
COWLES LANDSCAPE ARCHITECTURE
(CLA)
2285 TRESCOTT DRIVE
TALLAHASSEE, FL 32308
(850) 545-7035 www.cowlesLA.com
D a vi d
L . C o w le s, J r., R .L
.A
Fl o rid a
R e g . N o : L
A6 w w w .C
O W
LE
SL
A.
c o m
0)
-7
T
AL
LA
H
AS
SE
E, F
L
IR2.0
IR
RI
G A
TI
O
N D
ET
A
IL
S
H
EE
T
D O
W N
TO
W
N B
A
TH
RO
O
M S
RE
M
IN
G
TO
N
A
VE
N
UE
C
IT
Y O
F
TH
O M
A
SV
IL
LE
TH
O
M A
SV
IL
LE
, G
EO
RG
IA
9/29/2023
DLC
PRO FLEX SWING JOINT:
HUNTER 'PRO-FLEX' TUBING
24"-36", HSBE-050 ELBOWS (2),
MARLEX STREET ELBOW (1)
LATERAL TEE OR ELL
FINISH GRADE
MODEL PCB BUBBLER
HUNTER PCB BUBBLER DETAIL
NOT TO SCALE
LATERAL PIPE
MANUFACTURER:
NDS, INC.
851 NORTH HARVARD AVE.
LINDSAY, CA 93247
www.ndspro.com
TOLL FREE: 1-800-726-1994
PHONE: (559) 562-9888
FAX: (559) 562-4488
NOTES:
1. INSTALLATION TO BE
COMPLETED IN
ACCORDANCE WITH
MANUFACTURER'S
SPECIFICATIONS.
2. DO NOT SCALE DRAWING.
3. ALL INFORMATION
CONTAINED HEREIN WAS
CURRENT AT THE TIME OF
DEVELOPMENT BUT MUST BE
REVIEWED AND APPROVED
BY THE PRODUCT
MANUFACTURER TO BE
CONSIDERED ACCURATE.
PERSPECTIVE
PART
NUMBER
BOX &
COVER
314BC
314BCB
314BCSAND
314BCBSAND
314BNHCWG
314PBCR
314PBCBR
314PBCR NH
314BCRG
COVER ONLY
313C
313CSAND
313CR
313CRG
BOX ONLY
314B
314BSAND
314PB
314BNH
314PBNH
214-6
113BB
DESCRIPTION - MARKING
14"X19" BOX, OVERLAPPING COVER - ICV
14"X19" CORRUGATED BOX, OVERLAPPING
BOLT-DOWN COVER -ICV
14"X19" CORRUGATED BOX W/ NO HOLES
OVERLAPPING COVER - ICV
14"X19" BOX, OVERLAPPING COVER - ICV
14"X19" CORRUGATED BOX, OVERLAPPING
BOLT-DOWN COVER -ICV
14” X 19” CORRUGATED BOX W/NO
HOLES, OVERLAPPING COVER
RECLAIMED WATER
14"X19" BOX, OVERLAPPING COVER -
RECLAIMED WATER
14"X19" CORRUGATED BOX, OVERLAPPING
BOLT-DOWN COVER - RECLAIMED WATER
14"X19" CORRUGATED BOX W/ NO HOLES,
OVERLAPPING COVER - RECLAIMED WATER
14"X19" BOX, 14"X19" OVERLAPPING COVER -
RECLAIMED WATER
14"X19" OVERLAPPING COVER - ICV
14"X19" OVERLAPPING COVER - ICV
14"X19" OVERLAPPING COVER -
RECLAIMED WATER
14"X19" OVERLAPPING COVER -
RECLAIMED WATER
14"X19" BOX
14"X19" BOX
14"X19" BOX
14"X19" CORRUGATED BOX W/ NO HOLES
14"X19" CORRUGATED BOX W/ NO HOLES
14"X19"X6" EXTENSION
2-1/2" X 3/8" SS BOLT
COLOR
(BOX/COVER)
GREEN/
GREEN
GREEN/
GREEN
SAND/
SAND
SAND/
SAND
PURPLE/
PURPLE
PURPLE/
PURPLE
PURPLE/
PURPLE
PURPLE/
PURPLE
GREEN/
GREEN
GREEN
SAND
PURPLE
GREEN
GREEN
SAND
PURPLE
GREEN
PURPLE
GREEN
STEEL
PALLET
QTY.
(BAG OF
10)
PRODUCT
CLASS
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20PR
20NM
21"20"14 3/4"15 3/4"
11 3/4"17"
13 1/4" 24 3/8"
6 3/4"
11 3/4" 17"
15 3/8"10 1/8"
16 1/4" 11"
2"
PRO PLUS SERIES VALVE BOXES DETAIL
NOT TO SCALE
PERSPECTIVE
PERSPECTIVE
FINISH GRADE
3/4" MINUS WASHED GRAVEL
BRICK SUPPORTS (4)
MAIN LINE PIPE & FITTINGS
SCH 80 T.O.E. NIPPLE
REMOTE CONTROL VALVE MODEL
PGV-101G / 151 G
ACCU-SYNC-40
STANDARD VALVE BOX
WATERPROOF CONNECTORS (2)
18-24" COILED WIRE
PVC SLIP UNIONS
HUNTER PGV GLOBE VALVE DETAIL
NOT TO SCALE
MODEL MINI-CLIK
EXTERIOR WALL OR POST
(SEE NOTE)
RUN LEAD WIRES
TO CONTROLLER
NOTE:
MOUNT SENSOR ON SURFACE WHERE IT WILL
BE EXPOSED TO UNOBSTRUCTED RAINFALL,
BUT NOT IN PATH OF SPRINKLER SPRAY.
HUNTER MINI-CLIK RAIN SENSOR DETAIL
NOT TO SCALE
SWING JOINT:
HUNTER 'PRO-FLEX' TUBING,
HSBE-050 ELBOWS (2), &
MARLEX STREET ELBOW (1)
MODEL PROS-12-PRS40-CV
MP ROTATOR SPRAY HEAD
FINISH GRADE
LATERAL TEE OR ELL
LATERAL PIPE
HUNTER PROS-12-PRS40-CV SPRAY HEAD DETAIL
NOT TO SCALE
CONTROL WIRE IN ELECTRICAL
CONDUIT. SIZE AND TYPE
PER LOCAL CODE
NOTE:
MOUNT CONTROLLER WITH
LCD SCREEN AT EYE LEVEL.
CONTROLLER SHALL BE
HARD-WIRED TO GROUNDED
110 VAC SOURCE.
MINIMUM CLEARANCE
FOR DOOR OPENING EXTERIOR WALL
1.81'
MODEL PC-XX00
ELECTRICAL SUPPLY CONDUIT.
CONNECT TO POWER SOURCE.
J BOX INSIDE CONTROLLER.
HUNTER PRO-C WALL-MOUNT CONTROLLER DETAIL
NOT TO SCALE
4"
FINISH
GRADE
DIRECTION OF FLOW
975XL2
WILKINS
ZURN
WILKINSXL
METER & BACKFLOW DETAIL
NOT TO SCALE
OPTIONAL LEAD-FREE
STRAINER (MODEL SXL)
WATER METER
PER LOCAL
MUNICIPALITY
STANDARDS
INLET SHUT-OFF
DRAIN
PROTECTIVE
ENCLOSURE
AIR GAP
12" MIN.
30" MAX.
ZURN MODEL 975XL2
REDUCED PRESSURE PRINCIPLE
ASSEMBLY (SIZE PER PLAN)
FINISH
GRADE
BRICK
LA
TE
RA
L
PI
PE
M
AI
N L
IN
E)
NOTES:
1. PREVENT UNCOVERED PIPE FROM FLOATING UP DURING RAINS. PIPE WHICH FLOATS-UP
DUE TO WATER ACCUMULATION IN TRENCH SHALL BE RESET TO SPECIFIED DEPTHS AT NO
EXTRA COSTS.
2. TRENCH WIDTH TO BE SIZED ACCORDING TO NEEDS. DO NOT DIG EXCESSIVELY WIDE
TRENCH SO AS TO MINIMIZE DAMAGETO SURROUNDING SOILS AND VEGETATION.
FINAL
GRADE
4" MINIMUM
(SEE NOTE #2)
"DUCT" TAPE INDIVIDUAL WIRES
TOGETHER, BUT DO NOT ATTACH
TO PIPE.
PIPES AS SHOWN, SIZE AS
INDICATED ON PLAN.
MAINLINE TO BE PLACED ON
BOTTOM WHEN IN TRENCH
WITH LATERAL. ONE BUNDLE OF
WIRING PER TRENCH.
TRENCHING DETAIL
NOT TO SCALE
PLAN
SECTION
TRENCH
WIDTH
LAY WIRES IN TRENCH - CURVING
AS SHOWN BELOW TO PRODUCE
SLACK.
INSTALL TRACER WIRE
6" ABOVE ALL
IRRIGATION MAIN LINES
RE
M
IN
G
TO
N
A
VE
N
UE
1 inch = ft.
GRAPHIC SCALE
2 84
PROPOSED DOWNTOWN RESTROOMS
105 REMINGTON AVENUE
(SEE ARCHITECTURAL PLANS)
PROPOSED WALL
(SEE ARCHITECTURAL PLANS)
PROPOSED HARD SURFACE / PLAZA
(SEE ARCHITECTURAL PLANS)
PR
O
PO
SE
D R
AM
P
(S
EE
A
RC
H
ITE
C
TU
RA
L
PL
AN
S)
PR
O
PO
SE
D R
AM
P
(S
EE
A
RC
H
ITE
C
TU
RA
L
PL
AN
S)
PROPOSED WALL
(SEE ARCHITECTURAL PLANS)
PROPOSED ROOF OVERHANG
(SEE ARCHITECTURAL PLANS)
SITE BOUNDARY (TYP.)
PROPOSED HARDSCAPE / PLAZA
(SEE ARCHITECTURAL PLANS)
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
PROPOSED WALL
(SEE ARCHITECTURAL PLANS)
PROPOSED WALL
(SEE ARCHITECTURAL PLANS)
EXISTING
CONCRETE
EXISTING
CONCRETE
EXISTING
CONCRETE
EXISTING
CONCRETE
PROPOSED SURFACE DRAINS
(SEE CIVIL PLANS)PROPOSED FENCE
(SEE ARCHITECTURAL PLANS)
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
O E
EXISTING OVERHEAD UTILITY
(APPROXIMATE LOCATION)
EXISTING
LANDSCAPING
AREA
1 inch = ft.
GRAPHIC SCALE
2 84
T R E E S
ULMUS PARVIFOLIA ‘EMER II’ ALLEE UP
SYMBOL
PLANTING SCHEDULE
QTY. BOTANICAL NAME COMMON NAME SIZE/REMARKS
7-8' HT. X 3-4' SPR., 2" CAL., 30 GAL.1
S H R U B S
ROSA HYBRIDA 'KORVIOROS' SUNBELT SAVANNAH TEA ROSE 18" X 15", 3 GAL., 30" O.C.RH
MUHLENBERGIA CAPILLARIS 'WHITE CLOUD' WHITE CLOUD MUHLY GRASS 18" X 15", 3 GAL., 30" O.C.MC
ZOYSIA GRASSZOYSIA JAPONICA SOD ALL DISTURBED AREAS NOT PLANTED
T U R F G R A S S / L A W N
SOD 170
LEGEND
ACOMA CRAPE MYRTLE (WHITE)
SUNBELT SAVANNAH TEA ROSE
WHITE CLOUD MUHLY GRASS
PODOCARPUS 'MAKI'
ZOYSIA SOD
PINE STRAW MULCH
PODOCARPUS MACROPHYLLUS VAR. MAKI PODOCARPUS 'MAKI' 16" X 16", 3 GAL., 24"' O.C.PM 18
ALLEE ELM
GENERAL NOTES:
1. ALL PLANT MATERIAL SHALL BE FLORIDA #1 AS CLASSIFIED IN "GRADES AND STANDARDS FOR NURSERY PLANTS 2022, SIXTH
EDITION, PUBLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES (OR GEORGIA EQUIVALENT).
2. PERFORM A SOIL TEST AND APPLY THE NECESSARY AMENDMENTS AND/OR FERTILIZER. THE PLANTING AREAS SHALL NOT BE UNSUITABLE COMPACTED BACKFILL, BUT FERTILE WELL DRAINED LOAMY TOPSOIL WITH AN APPROPRIATE RATIO OF NITROGEN, POTASSIUM, PHOSPHORUS AND MICRO-NUTRIENTS (CORRESPONDING TO THE NEEDS OF A SOIL TEST).
3. WATER SETTLE ALL PLANTING PITS TO REMOVE AIR BUBBLES AND STABILIZE PLANT MATERIAL.
4. PLANTING BACKFILL MIX SHALL BE AS PER SPECIFICATIONS. BACKFILL MIX SHALL BE FREE OF CLODS AND STONES OVER THE
DIAMETER OF 1".
5. ALL LANDSCAPE AREAS THAT RECEIVE MULCH OR ROCK COVER SHALL BE TREATED WITH PRE-EMERGENT WEED CONTROL BEFORE AND AFTER PLACEMENT, AT RATES RECOMMENDED BY THE MANUFACTURER. THE CONTRACTOR SHALL GUARANTEE CONTROL OF
ALL WEEDS FOR A PERIOD OF ONE YEAR FROM THE TIME OF FINAL ACCEPTANCE.
6. INSTALL PINE STRAW MULCH (OR APPROVED EQUAL) WITHIN ALL LANDSCAPE AREAS AT A MINIMUM OF 3" COMPACTED THICKNESS.
IF AN INDIVIDUAL TREE (NEWLY PLANTED OR EXISTING) IS SURROUNDED BY TURF, THE MULCH AREA SHALL BE DESCRIBED AS THE DIAMETER OF THE TRUNK IN TERMS OF RADIUS IN FEET. FOR EXAMPLE: 3" CALIPER TREE = 3' RADIUS (6' DIAMETER) MULCH AREA.
DO NOT PILE MULCH AROUND THE TRUNK OR ROOT FLARE.
9. SOD ALL DISTURBED AREAS UNLESS INDICATED TO CONTAIN SEED & MULCH, SHRUBS, GROUNDCOVER, MULCH OR OTHER
MATERIAL.
10.ALL REQUIRED LANDSCAPE AREAS AND BUFFER STRIPS SHALL BE PROVIDED WITH AN IRRIGATION SYSTEM TO ALLOW 100 PERCENT
COVERAGE.
11. THE IRRIGATION SYSTEM SHALL BE GUARANTEED BY THE CONTRACTOR FOR A MINIMUM OF TWO (2) YEARS AFTER FINAL APPROVAL.
12. THE CONTRACTOR SHALL WARRANTY ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM THE TIME OF FINAL ACCEPTANCE AND SHALL WARRANTY ALL PLANT MATERIAL REPLACED FOR A PERIOD OF ONE YEAR FROM THE TIME OF REPLACEMENT.
PROPOSED
METAL EDGING
ALLEE ELM
LAGERSTROEMIA INDICA X FAURIEI 'ACOMA'LI 7-8' HT. X 3-4' SPR., 2" CAL., 30 GAL.2 ACOMA CRAPE MYRTLE (OR MATCH EX.)
EXISTING TREE (APPROXIMATE)
PROPOSED
METAL EDGING
SHEET
SH
EE
T
TIT
LE
PR
O
JE
C T
N
AM
E
C
LI
EN
T
N
AM
E
RE
VI
SI
O
N S
DATE:
DRAWN BY:
COWLES LANDSCAPE ARCHITECTURE
(CLA)
2285 TRESCOTT DRIVE
TALLAHASSEE, FL 32308
(850) 545-7035 www.cowlesLA.com
D a vi d
L . C o w le s, J r., R .L
.A
Fl o rid a
R e g . N o : L
A6 w w w .C
O W
LE
SL
A.
c o m
0)
-7
T
AL
LA
H
AS
SE
E, F
L
LS1.0
LA
N
D
SC
A
PE
P
LA
N D
O W
N
TO
W N
B A
TH
RO
O M
S
RE
M
IN
G
TO
N A
VE
N
UE
C
IT
Y O
F
TH
O M
A
SV
IL
LE
TH
O
M A
SV
IL
LE
, G
EO
RG
IA
9/29/2023
DLC
| Thomasville Downtown Bathrooms - Addendum No. 2 Narrative.pdf |
| October 2, 2023 |
| LS1.0.pdf |
| Sheets and Views |
| 105-REMINGTON-LS-LS1-24X36 |
| 105-REMINGTON-LS-LS2-24X36 |
| IR2.0.pdf |
| Sheets and Views |
| 105-REMINGTON-IR-IR1-24X36 |
| 105-REMINGTON-IR-IR2-24X36 |
File details come from the government source that posted it. Updated .