20220310-CMOSS-IRS-v1-1-Dist-A-A518.pdf
PDF 1 MB Posted
- Solicitation number
- FY22-C5ISR-CMOSS
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
PPR
O
VED
FO
R
PU
B
LIC
R
ELEA
SE
C M
O SS Interoperability
R equirem ents Specification v 1.1
C5ISR/EW Modular Open Suite of Standards (CMOSS) Interoperability Requirements Specification Version 1.1
JOSEPH D. WELCH
Director C5ISR Center
Controlled by:
Office of the MOSA Chief Engineer, MOSA Management Office (MMO) FCDD-ISE-FD
APPROVED FOR PUBLIC RELEASE
APPROVED FOR PUBLIC RELEASE
10 March 2022
Approved by:
JOSEPH D. WELCH
Director C5ISR Center
WILLIAM C. HOPPE
Associate Director, Science and Technology and Engineering
DONALD A. REAGO
Executive Director, Research and Technology Integration Directorate
MICHAEL C. MONTELEONE
Executive Director, Engineering and Systems Integration Directorate
Reviewed by:
SETH A. SPOENLEIN
Assistant Director, Systems Integration Portfolio
JOHN J. SOOS
Deputy Assistant Director, Prototyping, Integration & Testing
JOHN C. NILSEN
Project Manager, MOSA Management Office by:
JASON M. DIRNER
MOSA Chief Engineer, MOSA Management Office
WELCH.JOSEP
H.D.1241937905
Digitally signed by
WELCH.JOSEPH.D.1241937905
Date: 2022.03.10 10:19:12 -05'00'
HOPPE.WILLIAM.C
HARLES.10443874
Digitally signed by
HOPPE.WILLIAM.CHARLES.1044387464
Reason I concur and recommend approval Date 2022.03.08 15 42 32 -05'00'
REAGO.DONALD.
A.JR.1229634280
Digitally signed by
REAGO.DONALD.A.JR.1229634
Date: 2022.03.01 08:57:36 -05'00'
MONTELEONE.MIC
HAEL.C.127941312
Digitally signed by
MONTELEONE.MICHAEL.C.127
9413128 Date: 2022.02.23 15:13:37 -05'00'
SPOENLEIN.SET
H.A.1241431637
Digitally signed by
SPOENLEIN.SETH.A.124143163
Date: 2022.02.15 16:44:55 -05'00'
SOOS.JOHN.
J.1228923075
Digitally signed by
SOOS.JOHN J.1228923075
Date: 2022.01.26 08 21 29 -05'00'
NILSEN.JOHN.
C.1256161652
Digitally signed by
NILSEN.JOHN.C.1256161652
Date: 2022.01.24 15:08:39 -05'00'
DIRNER.JASON.MIC
HAEL.1369520500
Digitally signed by
DIRNER.JASON.MICHAEL.1369
520500 Date: 2022.01.24 15:06:25 -05'00'
ParentID UID Portion Marking
Content Type Strength
CMOSS0001 (U)
0BC5ISR/EW Modular Open Suite of Standards (CMOSS) Interoperability Requirements Specification (IRS)
Information
CMOSS0002 (U) Version 1.1 Information CMOSS0003 (U) Dated 20220310 Information CMOSS0004 (U) [Change Log Table.png] Information CMOSS0005 (U) Table 1 - Change Log Information
CMOSS0006 (U)
1BPurpose Information
CMOSS0007 (U) The purpose of the CMOSS Interoperability Requirements Specification is to provide a common, configuration-controlled, Science, Technology, Engineering, Experimentation, Test & Evaluation and Acquisition minimum baseline technical requirements document. This allows US Army (T), and Joint, Interagency, Intergovernmental, Multinational (JIIM) (O), materiel developers and integrators to ensure CMOSS compliant/conformant solutions are over-the-interface(s)-interoperable with other components/systems developed to the same "shalls". This document also addresses the need for the US Army (T), and JIIM (O), to have a mechanism to codify critical, Government interoperability design choices at the 'speed of relevance', in the event that public-private consortium governance processes/timelines would negatively impact Army Modernization. It also allows the Government to add additional specificity above and beyond consortium-based standards in order to achieve the portability and reuse objectives of the US Army. Although there are significant benefits from leveraging Public-Private consortium-based open standards approaches, the Government must always maintain the ability to make and coordinate inherently Governmental decisions in the best interests of the Warfighter. The requirements within this document should be incorporated by reference in contracts, citing the document title, revision number, and effective date of publication.
'CMOSS#####' Unique Identifiers (UID) will typically be linked as 'parent requirements' from which materiel system, subsystem, component, etc. 'child requirements' are derived. This CMOSS Interoperability Requirements Specification is under the configuration control of the chartered C5ISR Center MOSA Management Office (MMO).
Information
CMOSS0008 (U)
2BBackground Information
Content Type Strength
CMOSS0009 (U) In January 2019, the secretaries of the Army, Navy, and Air Force signed a memo entitled, “Modular Open Systems Approaches (MOSA) for our Weapon Systems is a Warfighting Imperative,” directing MOSA standards to be included in all requirements, programming, and development activities for future weapon system modifications and new-start development. This direction was reinforced by the House Armed Services Committee report for the FY21 National Defense Authorization Act, which recommended that “CMOSS and SOSA military electronics standards be more tightly connected to use the same hardware pinout standards and, more importantly, the same software data transport protocols, such as the Modular Open RF Architecture (MORA), to further solidify a common Department of Defense-wide technical approach to create an open systems architecture standard by which small businesses and large primes can compete”.
Information
CMOSS0010 (U)
3BCapability Overview and Benefits Information
CMOSS0011 (U) The Command, Control, Computers, Communications, Cyber, Intelligence, Surveillance and Reconnaissance (C5ISR) Center-developed and managed C5ISR/Electronic Warfare Modular Open Suite of Standards (CMOSS) delivers on that intent. This MOSA approach:
Information
CMOSS0011 CMOSS0012 (U) •Reduces the size, weight and power (SWaP) footprint of C5ISR systems by enabling integration and hardware sharing for communications, position, navigation and timing (PNT), mission command, and electronic warfare (EW) capabilities.
Information
CMOSS0011 CMOSS0013 (U) •Allows for rapid technology insertion to keep pace with emerging needs, permitting capabilities that are innovative, yet unanticipated, to be quickly implemented using well-defined components with open interfaces. The components are commonly referred to as “cards” and “radioheads”.
Information
CMOSS0014 (U) CMOSS consists of the following suite of layered standards that are individually useful and can be combined to form a holistic converged architecture:
Information
CMOSS0014 CMOSS0015 (U) •Network-based interoperability to enable sharing of services, such as time and position. Information CMOSS0014 CMOSS0016 (U) •Hardware form factor to enable capability fielding using cards in a common chassis. Information CMOSS0014 CMOSS0017 (U) •Functional decomposition to allow for sharing of resources, such as antennas and amplifiers. Information CMOSS0014 CMOSS0018 (U) •Software frameworks to enable portability of software applications. Information
Content Type Strength
CMOSS0019 (U) Information
CMOSS0020 (U) Figure 1 - Layered Standards Information CMOSS0021 (U) The overall approach has been referred to as the "Universal A-Kit," where platforms come with one or more standard chassis and are already plumbed for power, networks, and radio frequency (RF) distribution. Hardware for capabilities such as communications, PNT, mission command, and EW can then be fielded in the form of cards physically inserted in a common chassis and radioheads bolted to standard mount points.
Information
CMOSS0022 (U) CMOSS has the potential to significantly reduce costs over the lifecycle of a system. Information CMOSS0023 (U) Logistics tails can be smaller due to common spares. Information CMOSS0024 (U) Unit costs can be reduced due to greater competition among vendors and economies of scale. Information CMOSS0025 (U) Sustainment organizations can avoid purchasing spares intended to last 30+ years and instead perform modernization by upgrading to the latest hardware as components are replaced.
Information
Content Type Strength
CMOSS0026 (U) Information
CMOSS0027 (U) Figure 2 - The image above represents a notional portrayal of a Next Generation Optionally Manned Fighting Vehicle featuring a CMOSS-based chassis and capability cards.
Information
CMOSS0028 (U)
4BCMOSS Requirements Information
CMOSS0029 (U) The following describes the CMOSS requirements for systems and associated components. Information CMOSS0030 (U) CMOSS supports systems ranging in scale from a fully integrated platform to a dismounted manpack chassis. Information CMOSS0031 (U) Examples of components within systems include chassis, transceiver cards, single board computers, timing cards, radioheads, and C5ISR applications.
Information
CMOSS0032 (U)
5BVehicular Integration for C4ISR/EW Interoperability (VICTORY) Information
CMOSS0033 (U) Background: The Vehicular Integration for C4ISR/EW Interoperability (VICTORY) initiative was started as a way to correct the problems created by the "bolt-on" approach to fielding equipment on US Army vehicles.
Information
CMOSS0034 (U) Implementation of VICTORY allows tactical platforms and systems to recover lost space while reducing weight and saving power.
Information
CMOSS0035 (U) Additionally, implementation allows platform systems to share information and provide an integrated picture to the crews. Information
Content Type Strength
CMOSS0036 (U) Finally, implementation provides an open architecture that will allow platforms to accept future technologies without the need for significant re-design.
Information
CMOSS0037 (U) Under the initiative, a framework for integration of C4ISR/EW and other electronic mission equipment on tactical platforms continues to be developed.
Information
CMOSS0038 (U) Additional information is available at DI2E (https://di2e.net/). Information CMOSS0039 (U) Systems, when in a vehicle mounted configuration, shall implement a VICTORY Data Bus that complies with the following
VICTORY specifications:
Threshold shall
CMOSS0039 CMOSS0040 (U) a. Switch <VT50900-V1.9> to provide core network transport. Threshold shall CMOSS0039 CMOSS0041 (U) b. Shared Processing Unit <VT51900-V1.9> to host portable software. Threshold shall CMOSS0039 CMOSS0042 (U) c. VDB Management Service <VT52200-V1.9> to enable basic network management functions. Threshold shall CMOSS0039 CMOSS0043 (U) d. Support a minimum 10/100 Base-T Ethernet interface as specified in VICTORY <VT52303-V1.2> and <VT52101-V1.9>. Threshold shall
CMOSS0044 (U) All systems and components shall implement services to receive/consume external PNT data from authorized source such as PNT Mounted system.
Threshold shall
CMOSS0044 CMOSS0045 (U) All systems and components shall comply with the following VICTORY specifications: Threshold shall CMOSS0045 CMOSS0046 (U) a. Position Service (POS) <VT50100-V1.9> whenever position data is required. Threshold shall CMOSS0045 CMOSS0047 (U) b. Time Synchronization Service <VT50000-V1.7> with Precision Time Protocol (PTP) per VICTORY <VT50001.T2-V1.7> or
Network Time Protocol (NTP) per VICTORY <VT50001.T1-V1.4> whenever time synchronization is required.
Threshold shall
CMOSS0045 CMOSS0048 (U) c. Orientation Service <VT50200-V1.9> whenever orientation data is required. Threshold shall CMOSS0045 CMOSS0049 (U) d. Direction of Travel Service <VT50300-V1.9> whenever direction of travel (heading) data is required. Threshold shall
CMOSS0050 (U) Position, Navigation, and Timing (PNT) systems shall implement services to distribute PNT data for other client systems’ consumption:
Threshold shall
CMOSS0050 CMOSS0051 (U) a. Position Service (POS) <VT50100-V1.9> Threshold shall CMOSS0050 CMOSS0052 (U) b. Time Synchronization Service <VT50000-V1.7> Threshold shall CMOSS0050 CMOSS0053 (U) c. Orientation Service <VT50200-V1.9> Threshold shall CMOSS0050 CMOSS0054 (U) d. Direction of Travel Service <VT50300-V1.9> Threshold shall
CMOSS0055 (U) PNT systems shall implement the following services to enable remote management & control functions: Threshold shall CMOSS0055 CMOSS0056 (U) a. Global Positioning Service (GPS) Receiver < VT61000-V1.9> Threshold shall CMOSS0055 CMOSS0057 (U) b. Assured PNT <VT61600-V1.9> Threshold shall
CMOSS0058 (U) Tactical radios shall implement Data Radio <VT60800-V1.9> and Legacy Radio <VT60200-V1.9> to enable remote management & control functions.
Threshold shall
Content Type Strength
CMOSS0059 (U) Electronic Warfare (EW) and Signals Intelligence (SIGINT) systems shall implement Electronic Warfare Device <VT60900-V1.9> to enable remote management & control functions.
Threshold shall
CMOSS0059 CMOSS0060 Note that the Electronic Warfare Device component type will be deprecated in the future as the corresponding functionality will be provided by additional MORA Processing Resource component types.
Information
CMOSS0061 (U)
6BModular Open RF Architecture (MORA) Information
CMOSS0062 (U) Background: MORA extends VICTORY to support radio frequency (RF) systems. Information CMOSS0063 (U) MORA decomposes monolithic radio systems into high-level devices with well-defined functions and interfaces. Information CMOSS0064 (U) Devices include Software Defined Radios (SDRs), RF Conditioning and Distribution (RCD), and Radioheads (RHDs). Information CMOSS0065 (U) Additional information is available at DI2E (https://di2e.net/). Information CMOSS0066 (U) Please refer to “MORA DI2E Instructions” to request access to the MORA project on DI2E. Information CMOSS0067 (U) Systems shall comply with the MORA functional decomposition and interfaces. Threshold shall CMOSS0068 (U) Components containing signal resources such as but not limited to amplifiers, antennas, filters and switches shall implement the MORA Device <MT92010-V2.4> interfaces as specified in the MORA Specification.
Threshold shall
CMOSS0069 (U) Components containing signal resources such as but not limited to amplifiers, antennas, filters and switches shall implement the MORA Signal Resource Manager <MT92013-V2.4> interfaces as specified in the MORA Specification.
Threshold shall
CMOSS0070 (U) Components containing signal resources such as but not limited to amplifiers, antennas, filters and switches shall implement the MORA Signal Port Manager <MT92016-V2.4> interfaces as specified in the MORA Specification.
Threshold shall
CMOSS0071 (U) MORA interfaces shall include all required specifications as well as any optional specifications that correspond to functionality provided by the component.
Threshold shall
CMOSS0072 (U) Cascaded signal resources on different components shall communicate exclusively using MORA standard interfaces. Threshold shall CMOSS0072 CMOSS0073 (U) Signal resources shall be discovered and allocated over the VICTORY Data Bus (VDB). Threshold shall CMOSS0072 CMOSS0074 (U) Signal resources shall be controlled over the MORA Low Latency Bus (ML2B). Threshold shall
CMOSS0075 (U) Applications and processing resources shall interface with signal resources exclusively using MORA standard interfaces. Threshold shall CMOSS0075 CMOSS0076 (U) Signal resources shall be discovered and allocated over the VDB. Threshold shall CMOSS0075 CMOSS0077 (U) Signal resources shall be controlled over the ML2B. Threshold shall
CMOSS0078 (U) Systems and components should implement separate domains where the VDB is Domain 1 and the ML2B is Domain 2. Objective should
CMOSS0079 (U)
7BOpenVPX Information CMOSS0080 (U) Background: OpenVPX is a Backplane standard that uses serial fabrics with a high density connector, coupled with a systems level approach that defines standard profiles for pins, protocols, and interconnections.
Information
CMOSS0081 (U) Additional information is available at http://www.vita.com/ and http://www.opengroup.org/sosa Information
Content Type Strength
CMOSS0082 (U) Systems shall contain an OpenVPX chassis with modular hardware resources that complies with the slot and module profiles in this specification to facilitate interoperability with cards developed by third-party vendors.
Threshold shall
CMOSS0082 CMOSS0083 (U) System should use 3U OpenVPX whenever possible. Objective should CMOSS0084 (U) Systems and components shall use the Control Plane for the VICTORY Data Bus (VDB) and the Data Plane for the MORA Low
Latency Bus (ML2B).
Threshold shall
CMOSS0085 (U) Systems and components should implement separate domains on the backplane and plug-in cards where the Control Plane and Expansion Plane are Domain 1, while the Data Plane and Utility Plane are Domain 2.
CMOSS0086 (U) 3U payload cards such as RF transceivers that require RF connections shall comply with a slot profile of SLT3-PAY- 1F1U1S1S1U1U2F1H-14.6.11-4 as defined in ANSI/VITA 65.0, and shall have an Alternate Module Profile Scheme (AMPS) string that conforms to Table 2.
Threshold shall
CMOSS0086 CMOSS0087 (U) Connections on the front of these payload cards shall only be used for key fill and maintenance. Threshold shall CMOSS0088 (U) RF connections shall comply with the coaxial pin assignment in Figure 3. Threshold shall CMOSS0089 (U) 3U payload cards such as single board computers (SBCs) and general-purpose graphics processing units (GPGPUs) that don’t require RF connections shall comply with a slot profile of SLT3-PAY-1F1U1S1S1U1U2F1H-14.6.11-0 as defined in ANSI/VITA 65.0, and shall have an AMPS string that conforms to Table 2.
Threshold shall
CMOSS0089 CMOSS0090 (U) Connections on the front of these payload cards shall only be used for key fill and maintenance. Threshold shall CMOSS0091 (U) 3U payload cards that require standard I/O such as USB, DisplayPort, and serial ports or are intended to be used for system-specified interfaces shall comply with a slot profile of SLT3-PAY-1F1F2U1TU1T1U1T-14.2.16 as defined in ANSI/VITA 65.0, and shall have an Alternate Module Profile Scheme (AMPS) string that conforms to Table 2.
Threshold shall
CMOSS0091 CMOSS0092 (U) Connections on the front of these payload cards shall only be used for key fill and maintenance. Threshold shall CMOSS0093 (U) Systems that require more system-specific interfaces than can be accommodated by 14.2.16 may use a dedicated external I/O card. This card shall comply with a slot profile of SLT3-PAY-2U2U-14.2.17 as defined in ANSI/VITA 65.0, and shall have an Alternate Module Profile Scheme (AMPS) string that conforms to Table 2.
Threshold shall
CMOSS0093 CMOSS0094 (U) Connections on the front of these payload cards shall only be used for maintenance. Threshold shall CMOSS0095 (U) 3U Ethernet switch cards shall comply with a slot profile of SLT3-SWH-6F1U7U-14.4.14 or SLT3-SWH-4F1U7U1J-14.8.7-n as defined in ANSI/VITA 65.0, and shall have an AMPS string that conforms to Table 3.
Threshold shall
CMOSS0095 CMOSS0096 (U) Connections on the front of Ethernet switch cards shall only be used for external Ethernet connections, key fill, and maintenance.
Threshold shall
CMOSS0097 (U) 3U PCIe/Ethernet switch cards shall comply with a slot profile of SLT3-SWH-6F8U-14.4.15 as defined in ANSI/VITA 65.0, and shall have an AMPS string that conforms to Table 3.
Threshold shall
CMOSS0097 CMOSS0098 (U) Connections on the front of PCIe/Ethernet switch cards shall only be used for maintenance. Threshold shall
Objective should
CMOSS0086
Content Type Strength
CMOSS0099 (U) 6U payload cards such as RF transceivers that require RF connections shall comply with a slot profile of SLT6-PAY- 4F2Q1H4U1T1S1S1TU2U2T1H-10.6.4-2 as defined in ANSI/VITA 65.0, and shall have an AMPS string that conforms to Table 13.3.4-2 in SOSA Technical Standard Edition 1.0.
Threshold shall
CMOSS0099 CMOSS0100 (U) Connections on the front of these payload cards shall only be used for key fill and maintenance. Threshold shall CMOSS0099 CMOSS0101 (U) RF connections shall comply with the coaxial pin assignment in Figure 3. Threshold shall
CMOSS0102 (U) 6U payload cards such as SBCs and GPGPUs that don’t require RF connections shall comply with a slot profile of SLT6-PAY- 4F2Q1H4U1T1S1S1TU2U2T1H-10.6.4-0 as defined in ANSI/VITA 65.0, and shall have an AMPS string that conforms to Table 13.3.4-2 in SOSA Technical Standard Edition 1.0.
Threshold shall
CMOSS0102 CMOSS0103 (U) Connections on the front of payload cards shall only be used for key fill and maintenance. Threshold shall CMOSS0104 (U) 6U Ethernet switch cards shall comply with a slot profile of SLT6-SWH-14F16U1U15U1J-10.8.1-n as defined in ANSI/VITA 65.0, and shall have an AMPS string that conforms to Table 13.3.5-1 in SOSA Technical Standard Edition 1.0.
Threshold shall
CMOSS0104 CMOSS0105 (U) Connections on the front of Ethernet switch cards shall only be used for external Ethernet connections, key fill, and maintenance.
Threshold shall
CMOSS0106 (U) Timing cards shall comply with a slot profile of SLT3x-TIM-2S1U22S1U2U1H-14.9.2-1 as defined in ANSI/VITA 65.0, and shall have an AMPS string that conforms to Table 2.
Threshold shall
CMOSS0106 CMOSS0107 (U) Connections on the front of timing cards shall only be used for key fill and maintenance. Threshold shall CMOSS0108 (U) Switch cards shall support auto-negotiation and fixed rates. Threshold shall CMOSS0109 (U) Non-switch cards should support auto-negotiation and fixed rates. Objective should CMOSS0110 (U) All cards shall only use the following power inputs from the backplane: 12 VDC (Vs1), 3.3V_AUX, and VBAT. Threshold shall CMOSS0111 (U) Payload cards and timing cards shall support a 100 MHz REF_CLK and 1 PPS AUX_CLK that are distributed radially over the backplane.
Threshold shall
CMOSS0112 (U) All cards shall zeroize when GDiscrete1 is asserted. Threshold shall CMOSS0113 (U) All cards shall be Type 1, 1.0 in. pitch conduction cooled plug-in units per ANSI/VITA 48.2 or Type 1, 1.5 in. pitch air flow through plug-in units per ANSI/VITA 48.8 to support 2 Level Maintenance.
Threshold
CMOSS0113 CMOSS0114 (U) Cards should use ANSI/VITA 48.2 whenever possible. Objective should CMOSS0115 (U) Systems should conform to the Out-of-Band Hardware Management Definitions within the Sensor Open Systems Architecture
(SOSA TM) Technical Standard whenever possible.
Objective should
CMOSS0115 CMOSS0116 (U) These requirements can be found in Section 6.4 (Out-of-Band Hardware Management Definitions) of SOSA Technical Standard Edition 1.0 and are based on the Hardware Open Systems Technology (HOST) and ANSI/VITA 46.11 standards.
Information
CMOSS0117 (U) All cards shall conform to the plug-in card specifications within the Sensor Open Systems Architecture (SOSA TM) Technical Standard that don’t conflict with requirements within this document.
Threshold shall
CMOSS0117 CMOSS0118 (U) These requirements can be found in Section 13 (Hardware Element) of SOSA Technical Standard Edition 1.0. Information shall
Content Type Strength
CMOSS0119 (U) In the case of a conflict, this document shall supersede the SOSA TM Technical Standard. Threshold shall CMOSS0120 (U) Threshold shall
CMOSS0121 (U) Figure 3 - 3U Payload Card Coaxial Pin Assignment Information
CMOSS0122 (U) Threshold shall
Content Type Strength
CMOSS0123 (U) Table 2 - AMPS Strings for 3U Payload Plug-In Card Profiles (adapted from Table 13.3.4-1 in SOSA Technical Standard Edition 1.0)
Information
CMOSS0124 Threshold shall
CMOSS0125 (U) Table 3 - AMPS Strings for 3U Switch Plug-In Card Profiles (adapted from Table 13.3.5-1 in SOSA Technical Standard Edition 1.0) Information
CMOSS0126 (U)
8BSoftware Frameworks Information CMOSS0127 (U) Background: Software frameworks enable portability of applications between hardware platforms. Information CMOSS0128 (U) CMOSS leverages prominent software frameworks within each mission area to maximize reuse of existing software capabilities. Information CMOSS0129 (U) Software frameworks can be integrated with underlying specifications such as VICTORY and MORA which provide standard interfaces to sensors and services on the platform.
Information
CMOSS0130 (U) Additional information is available at https://redhawksdr.github.io/Documentation/, http://www.public.navy.mil/jtnc/, and http://www.opengroup.org/face/.
Information
CMOSS0131 (U) Systems shall implement applications within REDHAWK/TOA, SALVAGE, X-Midas, Photon, Software Communications Architecture (SCA), and/or Future Airborne Capability Environment (FACE) when appropriate.
Threshold shall
CMOSS0132 (U) Where existing Government frameworks are determined to be insufficient for a required application, such as in cases where hardware acceleration is used, the contractor shall document the design choices and provide the explanation to the Government for their concurrence.
Threshold shall
Content Type Strength
CMOSS0133 (U) The contractor shall deliver a Software Development Kit (SDK) or Integrated Development Environment (IDE) to facilitate development and deployment of applications for lower level processing hardware, such as hardware accelerators, that may not be covered by existing Government frameworks.
Threshold shall
CMOSS0134 (U)
9BMechanical and Electrical Interfaces Information
CMOSS0135 (U) Background: The Sensor Open Systems Architecture (SOSA TM) Technical Standard defines standard mounts and connectors in order to facilitate platform integration and maximize cable reuse.
Information
CMOSS0136 (U) Additional information is available at http://www.opengroup.org/sosa/. Information CMOSS0137 (U) Systems should conform to the mechanical and electrical specifications within the SOSA TM Technical Standard whenever possible.
should
CMOSS0138 (U) These requirements can be found in Section 13.5 (SOSA Aperture and Chassis Electrical and Mechanical Interface Standard) of SOSA Technical Standard Edition 1.0.
Information
CMOSS0139 (U) Reserved Information CMOSS0140 (U) Reserved Information CMOSS0141 (U) Reserved Information CMOSS0142 (U) Reserved Information CMOSS0143 (U) Reserved Information CMOSS0144 (U) Reserved Information
Auto-generated from Authoritative Source: https://armyeitaas.sharepoint-mil.us/teams/MMO/Lists/cmossIRS/
Data is valid as of: 2021-12-08_1627EST
Objective
File details come from the government source that posted it. Updated .