This is a Department of Defense Design Criteria Standard (MIL-STD-1623E with Change 1, dated April 19, 2010) establishing fire performance requirements and approved specifications for interior finish materials and furnishings used on Naval surface ships and submarines.

The standard applies to bulkhead sheathing, overhead sheathing, furniture, draperies and curtains, deck coverings, insulation, and bedding applications. Table I specifies material requirements across these categories with corresponding fire tests and performance limits. For bulkhead and overhead sheathing, approved materials include high-pressure laminates, PVC film-aluminum laminates, and PVF film-aluminum laminates, all requiring ASTM E84 or UL 723 testing with flame spread indices not exceeding 25. Furniture requirements include vinyl upholstery, polychloroprene cushioning, and various laminate types tested to ASTM D6413 and ASTM E162 standards. Deck coverings encompass vinyl tiles, rubber tiles, vinyl sheets, terrazzo, latex mastic, and latex concrete, all requiring ASTM E648 testing with minimum critical radiant flux of 0.45 w/cm². Insulation materials include pipe insulation, insulating boards, insulating felts, glass cloth, cellular foam, and high-temperature fire/thermal/acoustic insulation tested per ASTM E84, ASTM E162, or 46 CFR 164.009 depending on material type. Bedding components including mattresses, cushioning, covers, and blankets must meet ASTM D6413 and NFPA 267 requirements. Section 5.2.1 mandates that manufacturers conduct all fire tests through independent laboratories accredited to ISO/IEC 17025 or equivalent by recognized bodies such as A2LA or IAS, with the Government reserving witness and testing rights. Change 1 modifications updated references to MIL-PRF-24667 for deck coatings, corrected insulating board requirements, and added MIL-STD-3020 for fire resistance test methods for N-Class divisions.

View the file

Other files for this federal contract opportunity

Other files attached to Mattresses, newest first.
File Type Posted
FAR Clauses.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INCH-POUND

MIL-STD-1623E(NAVY)

w/CHANGE 1 19 April 2010

SUPERSEDING

MIL-STD-1623E(SH)

20 June 2006

DEPARTMENT OF DEFENSE

DESIGN CRITERIA STANDARD

FIRE PERFORMANCE REQUIREMENTS AND

APPROVED SPECIFICATIONS FOR INTERIOR

FINISH MATERIALS AND FURNISHINGS

(NAVAL SHIPBOARD USE)

AMSC N/A FSC 19GP

Source: https://assist.dla.mil -- Downloaded: 2015-11-05T20:46Z

Check the source to verify that this is the current version before use.

w/CHANGE 1

FOREWORD

1. This military standard is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense.

2. Comments, suggestions, or questions on this document should be addressed to Commander, Naval Sea Systems Command, ATTN: SEA 05S, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard, DC 20376- 5160 or emailed to commandstandards@navy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https://assist.daps.dla.mil/online .

ii https://assist.daps.dla.mil/online

SUMMARY OF CHANGE 1 MODIFICATIONS

1. The reference to MIL-PRF-17951 in table I, deck coverings, treads non-skid, was deleted and replaced with MIL-PRF-24667. MIL-PRF-17951 was cancelled and superseded by MIL-PRF-24667 on 8/7/2008.

2. The change to table I, insulating board, is proposed to correct an error. In the existing document, the requirement for MIL-I-742 core material, insulating board, Type I, was inadvertently mixed up with fire performance requirement for MIL-I-742 faced insulating board system (Type I). This error, if not corrected, could lead to mis-interpretation of acceptance criteria during qualification testing.

3. The reference to MIL-PRF-2818 in table I, insulating blanket, was deleted because there is no acceptable commercial specification readily available to replace it. Determining the suitable commercial replacement specification, or modifying an existing commercial specification to make it suitable for NAVSEA use, will require a significant amount of testing/tasking to establish compliance of a commercial specification with a variety of requirements typical of such a specification.

4. Added requirements for on-deck insulation to table I.

5. Replaced reference to MIL-PRF-32161 Appendix A with MIL-STD-3020 in table I, high temperature fire/thermal/acoustic insulation. MIL-STD-3020 is the new standard for all fire resistance test methods for N-Class divisions. Added MIL-STD-3020 to list of applicable documents in Section 2.

6. The following modifications to MIL-STD-1623E have been made:

Paragraph Modification

Foreword Changed

2.2.1 Changed

2.4 Changed

Table I Changed

6.4 Changed

iii

CONTENTS

PARAGRAPH PAGE

FOREWORD....................................................................................................................................................... ii Summary of change 1 modifications ................................................................................................................... iii

1. SCOPE

1.1 Scope 1

1.2 Applicability

1.3 Limitations

2. APPLICABLE DOCUMENTS

2.1 General

2.2 Government documents

2.2.1 Specifications, standards, and handbooks

2.2.2 Other Government documents, drawings, and publications

2.3 Non-Government publications

2.4 Order of precedence

3. DEFINITIONS

4. GENERAL REQUIREMENTS

5. DETAILED REQUIREMENTS

5.1 Materials

5.2 Fire test provisions

5.2.1 Responsibility for testing

5.2.2 Methods of testing

6. NOTES

6.1 Intended use

6.2 Acquisition requirements

6.3 Subject term (key word) listing

6.4 Change notations

TABLES

TABLE I. Material requirements TABLE II. Fire tests iv

1. SCOPE

1.1 Scope. This design criteria standard provides fire performance requirements and approved specifications for various categories of interior finish materials and furnishings for use on Naval surface ships and submarines.

1.2 Applicability. This design criteria standard applies to materials for bulkhead sheathing, overhead sheathing, furniture, draperies and curtains, deck coverings, insulation, and bedding applications. The fire performance requirements of this design criteria standard supersede those contained in the applicable specifications.

1.3 Limitations. Although the development of limits for toxic products of combustion is of major concern, the information generally available is not refined to the degree to allow inclusion of finite limits in this standard at this time. Components and materials not previously approved by the Navy will be evaluated for fire gas toxicity, off-gassing, health hazards, dermal irritation/sensitization, and other pertinent factors as determined by the Naval Technical Authority.

2. APPLICABLE DOCUMENTS

2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this standard. This section does not include documents cited in other sections of this standard or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this standard, whether or not they are listed.

2.2 Government documents.

2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

FEDERAL SPECIFICATIONS

CCC-C-436 - Cloth, Ticking Twill, Cotton

L-P-1040 - Plastic Sheets and Strips (Polyvinyl Fluoride)

FEDERAL STANDARDS

FED-STD-191 - Textile Test Methods

FED-STD-501 - Floor Coverings, Resilient, Nontextile: Sampling and Testing

COMMERCIAL ITEM DESCRIPTIONS

A-A-52085 - Cloth, Drill, Cotton

A-A-55188 - Blankets, Bed, Wool, Shrink Resistant and Mothproofed

A-A-59502 - Plastic Sheet, Polycarbonate

A-A-59517 - Cloth, Coated or Laminated, Polyvinylchloride (Artificial Leather)

DEPARTMENT OF DEFENSE SPECIFICATIONS

MIL-I-742 - Insulation Board, Thermal, Fibrous Glass

MIL-I-2781 - Insulation, Pipe, Thermal

MIL-PRF-2819 - Insulation Block, Thermal

MIL-D-3134 - Deck Covering Materials

MIL-PRF-3135 - Deck Covering Underlay Materials

- Matting or Sheet, Floor Covering Insulating for High Voltage Application MIL-DTL-15562

MIL-I-16411 - Insulation Felt, Thermal, Glass Fiber

MIL-P-17171 - Plastic, Laminate, Decorative, High Pressure

MIL-D-18873 - Deck Covering Magnesia Aggregate Mixture

MIL-C-20079 - Cloth, Glass; Tape, Textile Glass; and Thread, Glass

MIL-PRF-20092 - Rubber or Plastic Sheets and Assembled and Molded Shapes, Synthetic, Foam or Sponge Open Cell

MIL-A-21016 - Adhesive, Resilient Deck Covering

MIL-D-21631 - Deck Covering, Latex Concrete

MIL-I-22023 - Insulation Felt, Thermal and Sound Absorbing Felt, Fibrous Glass, Flexible

MIL-PRF-22344 - Insulation, Pipe, Thermal

MIL-C-22395 - Compound, End Sealing, Thermal Insulation Pipe Covering -Fire-, Water-, and Weather-Resistant

MIL-P-22581 - Plastic Tiles, Vibration Damping, Type III

MIL-A-23054 - Acoustical Absorptive Board, Fibrous Glass Perforated Fibrous Glass Cloth Faced

MIL-PRF-23653 - Plastic Tiles, Vibration Damping

MIL-PRF-24172 - Insulation, Plastic, Cellular Foam, Rigid, Preformed and Foam-in- Place

MIL-DTL-24191 - Plastic Sheet, Cell or Continuous Cast, Acrylic, Shipboard Application (Illumination and Signal Lighting)

MIL-C-24500 - Cloth, Drapery, Bunk Curtain, Slipcovers, and Labels, Fire Retardant

MIL-L-24518 - Laminate, Vinyl Film-Aluminum, Decorative

MIL-PRF-24613 - Deck Covering Materials, Interior, Cosmetic Polymeric

MIL-PRF-24667 - Coating System, Non-Skid, for Roll or Spray Application

DOD-I-24688 - Insulation Panel, Thermal and Acoustic Absorptive, Open-Cell Polyimide Foam

MIL-T-24708 - Thermal/Acoustic Insulation Barrier Material: Polyimide Foam

MIL-PRF-24712 - Coatings, Powder (Metric)

MIL-PRF-32161 - Insulation, High Temperature Fire Protection, Thermal and Acoustic

MIL-PRF-32170 - Deck Tiles, Wear-Resistant

MIL-PRF-32171 - Deck Coatings, High Durability

DEPARTMENT OF DEFENSE STANDARD

MIL-STD-3020 - Department of Defense Standard Practice for Fire Resistance of U.S.

Naval Surface Ships

(Copies of these documents are available online at https://assist.daps.dla.mil/online or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)

2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

NAVAL SEA SYSTEMS COMMAND

NAVSEA 05Z6 PD 5-04A - Mattress, Innerspring, Flame-Resistant, Shipboard

(Copies of this document are available from the Commander, Naval Sea Systems Command, ATTN: SEA 05Z, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160).

CODE OF FEDERAL REGULATIONS (CFR)

46 CFR 164.009 - Noncombustible Materials for Merchant Vessels

(Copies of this document are available from the Superintendent of Documents, U.S. Government Printing Office, Washington DC 20401 or online at www.gpoaccess.gov/index.html.)

2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

AMERICAN ASSOCIATION OF TEXTILE CHEMISTS AND COLORISTS (AATCC)

AATCC-135 - Dimensional Changes of Fabrics After Home Laundering

(Copies of this document are available from the American Association of Textile Chemists and Colorists, P.O. Box 12215, Research Triangle Park, NC 27709.)

ASTM INTERNATIONAL

ASTM D635 - Rate of Burning and/or Extent and Time of Burning of Self- Supporting Plastics in a Horizontal Position, Standard Test Method for

ASTM D6413 - Flame Resistance of Textiles (Vertical Test), Standard Test Method for

ASTM E84 - Surface Burning Characteristics of Building Materials

ASTM E162 - Surface Flammability of Materials Using a Radiant Heat Energy Source, Standard Test Method for

ASTM E648 - Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source, Standard Test Method for

ASTM E662 - Specific Optical Density of Smoke Generated by Solid Materials, Standard Test Method for

ASTM E1264 - Acoustical Ceiling Products, Standard Classification for

ASTM F1066 - Tile, Floor, Vinyl Composition, Standard Specification for

ASTM F1700 - Solid Vinyl Floor Tile, Standard Specification for

Source: https://assist.dla.mil -- Downloaded: 2015-11-05T20:46Z

Check the source to verify that this is the current version before use.

www.gpoaccess.gov/index.html

(Copies of these documents are available from ASTM International, 100 Barr Harbor Avenue, PO Box C700, West Conshohocken, PA, USA 19428-2959 or online at www.astm.org.)

ELECTRIC BOAT CORPORATION

EB Corp. Spec 4013 - Anti-Sweat and Refrigerant Insulation Systems (Sheets and Tubes)

(Copies of this document are available from Electric Boat Corporation, a General Dynamics Company, Department 447, Material Services, 75 Eastern Point Road, Groton, CT 06340-4899.)

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 267 - Fire Characteristics of Mattresses and Bedding Assemblies Exposed to Flaming Ignition Source

(Copies of this document are available from NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471 or online at www.nfpa.org.)

UNDERWRITERS LABORATORIES, INC. (UL)

UL 94 - Tests for Flammability of Plastic Materials

UL 723 - Test for Surface Burning Characteristics of Building Materials

(Copies of these documents are available from COMM 2000, 1414 Brook Drive, Downers Grove, IL 60515 or online at www.ul.com.)

2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

3. DEFINITIONS

This section is not applicable to this standard.

4. GENERAL REQUIREMENTS

This section is not applicable to this standard.

5. DETAILED REQUIREMENTS

5.1 Materials. Interior finish materials and furnishings shall meet the requirements set forth in table I.

Thickness for bulkhead sheathing, overhead sheathing, and furniture indicate maximum limits in both application and fire tests.

Check the source to verify that this is the current version before use.

http://www.astm.org/ http://www.nfpa.org/ http://www.ul.com/

TABLE I. Material requirements.

Category Material Specification Fire test Test limits Flame spread index 25 MAX High pressure laminate

MIL-P-17171,

Type IV

ASTM E84 or UL 723 15 MAX Smoke developed index

Flame spread index 25 MAX Fabric-backed vinyl Commercial ASTM E84 75 MAX Smoke developed index

0.035 inch

MAX

Vinyl thickness

Flame spread index 25 MAX Smoke developed index 75 MAX

PVC film-aluminum laminate

ASTM E84 or

UL 723

MIL-L-24518

0.011 inch

MAX

PVC film thickness

0.063 inch

MAX

Aluminum thickness

Flame spread index 25 MAX Smoke developed index 15 MAX

Bulkhead sheathing1 High pressure laminate pre-bonded to aluminum

ASTM E84 or

UL 723

MIL-P-17171 /

0.050 inch

MAX

Aluminum thickness

Flame spread index 25 MAX Smoke developed index 75 MAX

PVF film-aluminum laminate

PVF film thickness 0.004 inch

MAX

L-P-1040, Type II, Grade A, Class 1

ASTM E84 or

UL 723

0.063 inch

MAX

Aluminum thickness

9Plastic tile MIL-PRF- 23653

ASTM D635 /, 10/

9Plastic sheet MIL-P-22581 ASTM D635 /, 10/ Flame spread index 25 MAX ASTM E1264

Class A (all surfaces)

ASTM E84

Smoke developed index 50 MAX

Acoustical ceiling products

Class B (face side)

ASTM E84 Flame spread index 75 MAX

1.35 inch/minute

MAX

ASTM D635 Flame rate Acrylic light-diffusing panel/windows (lighting fixture only)

MIL-DTL-

24191

ASTM E66220/ Smoke density 50 MAX at

0.250 inch thickness

Overhead sheathing2/

Flame spread index 25 MAX Smoke developed index 35 MAX

Fibrous glass opaque suspended ceiling panel

Commercial ASTM E84

0.750 inch

MAX

Panel thickness

TABLE I. Material requirements – continued.

Flame spread index 25 MAX Smoke developed index 75 MAX

PVC film-aluminum laminate

ASTM E84 or

UL 723

MIL-L-24518

0.063 inch

MAX

Aluminum thickness

Flame spread index 25 MAX Smoke developed index 75 MAX

Overhead sheathing2 PVF film-aluminum laminate

PVF film thickness 0.004 inch

MAX

L-P-1040, Type II, Grade A, Class 1

ASTM E84 or

UL 723

continued

0.05 inch

MAX

Aluminum thickness

Char length 3 inch MAX After flame 2 sec MAX

A-A-59517, Class 4, Condition a

Vinyl upholstery ASTM D6413

Flaming droplets None Char length 3 inch MAX Upholstery fabric Commercial ASTM D6413 After flame 2 sec MAX Flaming droplets None

ASTM E162 Flame spread 10 MAX ASTM E66220/ Smoke density 200 MAX

Polychloroprene cushioning15

Net peak HRR 150 kW MAX

MIL-PRF-

20092, Type II, Class 5

Avg specific extinction area

300 m2/kg

MAX

MIL-PRF-

20092 Appendix A

Furniture

Burning droplets or flaming material19

None

Flame spread index 75 MAX Smoke developed index 50 MAX

High pressure laminate for table tops4

MIL-P-17171,

Type I

ASTM E84

0.062 inch

MAX

Laminate thickness

A-A-59502, Type II

Polycarbonate UL 94 Flammability V-0

Char length 3 inch MAX After flame 1 sec MAX

MIL-C-24500,

Type II13

Polyaramid/novoloid ASTM D6413

After glow 25 sec MAX ASTM E66220/ Smoke density 20 MAX

Char length 5 inch MAX After flame 1 sec MAX

MIL-C-24500,

Type I13

Polyaramid ASTM D6413

After glow 25 sec MAX

ASTM E66220/ Smoke density 20 MAX

Draperies and curtains5/

Char length 1.5 inch MAX Fibrous glass Commercial ASTM D6413 After flame 1 sec MAX After glow 2 sec MAX

ASTM E66220/ Smoke density 20 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux ASTM F1066 and ASTM F1700

Vinyl tile

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Fire-retardant plastic Commercial

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Vinyl sheet Commercial

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Rubber tile Commercial

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Vinyl tile or sheet with backing Commercial

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

Deck coverings7

ASTM E648 Critical radiant flux MIL-PRF- 24667

Treads non-skid

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux MIL-PRF-

24667 Epoxy non-skid

ASTM E66220/ Smoke density 450 MAX Char length 10 inch MAX Combustion time 4.0 minute

MAX

MIL-PRF-

FED-STD-501,

method 6411

Underlay

Ignition time7/ 20 sec MIN Char length 10 inch MAX Combustion time 4.0 minute

MAX

MIL-D-3134,

Type I, Class 1, Type I, Class 2

FED-STD-501,

method 6411

Terrazzo

Ignition time7/ 20 sec MIN Char length 10 inch MAX Combustion time 4.0 minute

MAX

MIL-D-3134,

Type II

FED-STD-501,

method 6411

Latex mastic

Ignition time7/ 20 sec MIN Char length 3 inch MAX Combustion time 4.0 minute

MAX

FED-STD-501,

method 6411

Latex concrete MIL-D-21631

Ignition time7/ 20 sec MIN

Char length 3 inch MAX Combustion time 4.0 minute

MAX

Magnesium aggregate

FED-STD-501,

method 6411

MIL-D-18873

Ignition time7/ 20 sec MIN

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Electrical grade mat or sheet

MIL-DTL-

155626/

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Carpet Commercial

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux MIL-PRF-

24667 Spray-on non-skid

ASTM E66220/ Smoke density 450 MAX

Deck coverings7

Flame spread 20 MAX continued

MIL-PRF-

24712

Powder coating ASTM E162 Dripping None

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Interior cosmetic polymeric

MIL-PRF-

24613

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Deck tiles, wear resistant

MIL-PRF-

32170

ASTM E66220/ Smoke density 450 MAX

0.45 w/cm2

MIN

ASTM E648 Critical radiant flux Deck coating, high durability

MIL-PRF-

32171

ASTM E66220/ Smoke density 450 MAX Flame spread index 25 MAX

Smoke developed index

15 MAX

MIL-I-742,

Type I

Insulating board ASTM E84

(faced board) 14/ Thickness

Pass8

Type I (Core only)

46 CFR 164.009 /

Pass8

Type II (unfaced board)

46 CFR 164.009 /

Insulation

Flame spread index 0 MAX Pipe insulation MIL-I-2781 ASTM E84 Smoke developed index

0 MAX

Flame spread index 25 MAX MIL-PRF- 22344

Pipe insulation ASTM E84 Smoke developed index

50 MAX

1 ft. on horizontal pipe runs

MAX

Flame spread Anti-sweat pipe insulation15

EB Corp Spec

Ignition of target array None

Room/corner test (see applicable specification, Appendix A)

Melting, dripping or flaming droplets

None

Heat release rate (material only)

11,384 Btu/minute (200 kW)

MAX

Flame spread index 0 MAX MIL-PRF-

Block insulation ASTM E84 Smoke developed index

0 MAX

Pass8Insulating felt MIL-I-16411 46 CFR 164.009 / 21Insulating blanket / 46 CFR 164.009 Pass8/

22On-deck insulation / 46 CFR 164.009 Pass8/ MIL-C-20079 (All tests before and after treatment) Type I, Classes 1, 3, 5, 7, 9

46 CFR 164.009 Pass8/ Insulation continued

Glass cloth

Flame spread index 20 MAX Type I, Class 2 ASTM E84 Smoke developed index

10 MAX

After flame and afterglow

0 sec MAX

Char length 0 inch MAX

Type I, Classes 4, 6, 8, ASTM D6413 or FED-STD- 191 Method 5903.2

Flame travel 1.5 inch MAX Pass8Type II, Classes 1, 3, 4

46 CFR 164.009 /

Flame spread index 20 MAX Type II, Class

ASTM E84

Smoke developed index

10 MAX

Flame spread index 25 MAX Smoke developed index

250 MAX

Cellular foam (Reefer spaces only)

MIL-PRF-

24172

ASTM E84

(before and after humid aging)

Foam thickness 1.0 inch MAX Melting, dripping, or flaming droplets

None

MIL-C-22395,

fire resistance

Burn after removal of a test flame

End sealer MIL-C-22395 30 sec MAX

Flame spread index 25 MAX MIL-I-22023 Type I and Type II

ASTM E84

Smoke developed index

50 MAX

Thermal/sound absorbing felt15/

MIL-I-22023

Appendix A

> 10 minute

MIN

Type III Flash-over time

ASTM E662 Smoke density 5 max Insulation continued DOD-I-24688, Type I DOD-I-24688 Appendix A

Flash-over time > 10 minute

MIN

Thermal/acoustic panel15/

Type II, Class 1 and 2

DOD-I-24688

Appendix A

> 10 minute

MIN

Flash-over time

Flame spread index 25 MAX MIL-PRF- 32161, Type I, II, and III

ASTM E84

Smoke developed index

50 MAX

High temperature fire/thermal/acoustic insulation15/

Type I MIL-STD-3020 Full-scale fire resistance test

Flame spread index12ASTM E162 / 25 MAX MIL-T-24708, Type I ASTM E66220/ Smoke density 150 MAX

Thermal/acoustic barrier15/

MIL-T-24708

Appendix

> 10 minute

MIN

Type I, Class 3 Flash-over time

Flame spread index 30 MAX ASTM E84 or

UL 723

Acoustic board MIL-A-23054 Smoke developed index

100 MAX

Component testing:

Upholstery Ticking, Border Ticking, Flange, Tape16/ and

Pocketing Material16/

NAVSEA

05Z6 PD 5-

04A

Mattress, innerspring

Initial flammability: ASTM D6413 Char length 5 inch MAX

Bedding

After flame 2 sec MAX Molten and/or flaming drops

None

Flammability after 15 launderings:

Char length 5 inch MAX

Mattress, innerspring continued

After flame 2 sec MAX

FED-STD-191

Method 5556 and ASTM D6413

Molten and/or flaming drops

None

NAVSEA

05Z6 PD 5-

04A continued

Cushioning and insulator pad Char length 5 inch MAX ASTM D6413 After flame 2 sec MAX Molten and/or flaming drops

None

Flame spread18ASTM E162 / 10 MAX Smoke density18/ 200 MAX ASTM E66220/ Molten and/or flaming drops

None

Finished mattress testing:

Net peak HRR 150 kW MAX Avg specific extinction area

300 m2/kg

MAX

NFPA 267 (with Navy exceptions)

Burning droplets or flaming material19

None

ASTM E162 Flame spread 10 MAX ASTM E66220/ Smoke density 200 MAX

Bedding continued

Mattress, polychloroprene15

Net peak HRR 150 kW MAX

MIL-PRF-

20092, Type II, Class 5

Avg specific extinction area

300 m2/kg

MAX

MIL-PRF-

20092 Appendix A

Burning droplets or flaming material19

None

Char length 5 inch MAX After flame 2 sec MAX

Treated cotton mattress ticking (non-launderable)3

CCC-C-436,

Type II, Class

ASTM D6413

Flaming droplets None Char length 5 inch MAX Mattress cover, cotton drill (launderable)3

A-A-52085, Type I, Class 2

ASTM D6413

After flame 2 sec MAX / Flame time 5 sec MAX Blanket17

Drip flame time 5 sec MAX

/ A-A-55188 Aircraft Material Fire Test Handbook , Chapter 18, Recommended Procedure for the 4-Ply Horizontal Flammability Test for Aircraft Blankets

Holing, flame penetration, or burn-through permitted

None

NOTES:

1/ Maximum test limits are based upon material bonded to a non-combustible substrate.

2/ Maximum test limits are based upon material attached to, or supported by, a non-combustible substrate.

3/ Use with polychloroprene mattress only.

4/ Wherever a flame spread index higher than 25 is indicated, the material is acceptable since there is no other acceptable material available with a lower flame spread index.

5/ An 8-ounce weight shall be used for materials tested in accordance with ASTM D6413.

6/ Cement test specimen with MIL-A-21016. Permit cement to dry a minimum of 72 hours before conducting fire test.

7/ Materials tested in accordance with method 6411 of FED-STD-501 shall exhibit ignition time no less than 20 seconds. Ignition time is defined as the time in seconds from the initial application of the burners on the sample until the first self-sustaining flame (ignition) is observed issuing from the top surface of the sample.

8/ Materials tested in accordance with 46 CFR 164.009 shall pass all requirements for noncombustibility.

9/ Specimen shall not burn to the 4-inch mark after the first or second ignition.

10/ No wire gauze shall be mounted beneath the specimen and only three (3) specimens cut from the same tile shall be tested. Each of the three (3) specimens shall pass. If any do not pass, the procedure in ASTM D635 which specifies tests in groups of ten (10) specimens (cut from the same tile) shall be followed.

11/ (a) The fire-containment assembly, with attached insulation, shall have withstood the fire endurance test without passage of flame for a time period equal to that for which the classification is desired, and (b) Transmission of heat through the assembly during the fire endurance test period shall not have raised the average temperature on its unexposed surface more than 250 °F (139 °C) above its initial temperature, nor the temperature of any one point on the surface, more than 325 °F (181 °C) above its initial temperature. The test shall be performed in both vertical and horizontal configurations.

12/ Type I shall be tested twice. One with the glass cloth cover facing the heat source, and one with the flexible polyimide foam facing the heat source.

13/ Material shall be tested as received and after five (5) launderings as per AATCC 135 Procedure IIIB in both warp and fill directions.

14/ Test at maximum thickness contemplated for use.

15/ Where test methods are non-standard, but are called out from within the specification or an Appendix to that specification, the test methods will be referenced as such.

16/ Only molten and/or flaming drops requirement applies to tape. Only initial flammability requirements apply to pocketing material.

17/ The A-A-55188 limits the use of blankets to wool material only. The fire performance requirements apply to alternative materials which are subject to approval by Naval Technical Authority.

18/ When materials are not identical on both sides, each side shall be tested as a different specimen (does not apply to cushioning).

19/ This means no flaming droplets or flaming material which fall from the test mattress during the fire test, shall continue flaming after reaching the test platform or floor.

20/ Where test method ASTM E662 is invoked, tests shall be conducted in both non-flaming and flaming modes.

21/ MIL-PRF-2818 has been cancelled without replacement. When this product is required, vendor/contractor shall submit recommended product specification to the Naval Technical Authority for approval prior to use.

22/ MIL-D-23134 has been inactivated. When this product is required, vendor/contractor shall submit recommended product specification to the Naval Technical Authority for approval prior to use.

5.2 Fire test provisions.

5.2.1 Responsibility for testing. Unless otherwise required in the applicable material specification, the manufacturer is responsible for conducting fire tests as specified herein. All tests specified in this document shall be conducted by an independent testing laboratory that is accredited to ISO/IEC 17025 or equivalent procedure.

Accreditation shall be obtained from a recognized accreditation body such as American Association for Laboratory Accreditation (A2LA) or International Code Council’s International Accreditation Services (IAS). The scope of accreditation shall include specific flammability and fire tests required for qualification. The Government reserves the right to witness the tests, and/or perform any of the tests set forth herein where such testing is deemed necessary to assure compliance to prescribed requirements.

5.2.2 Methods of testing. Fire tests shall be conducted on materials as specified in table I and the notes therein. All fire test procedures shall be in accordance with prescribed standards and test methods and, unless otherwise specified herein, no less than three specimens shall be tested on material of the same lot with results averaged (arithmetic means). Tests as listed in table II shall apply.

TABLE II. Fire tests.

Specification Description Surface flammability

ASTM D635 Burn rate test

ASTM E84 Tunnel test

ASTM E162 Radiant panel

ASTM E648 Flooring radiant panel

FED-STD-501,

Method 6411

Floor covering, fire resistance

UL 94 Flammability of plastics

Vertical flame resistance

ASTM D6413* Flame resistance of textiles

Smoke generation

ASTM E84 Tunnel test

ASTM E662 Specific optical density of smoke

Test for noncombustibility

46 CFR 164.009 Heated tube test

Fire endurance

NFPA 267** Fire characteristics of mattresses

UL 1709** Hydrocarbon pool fire exposure test

* A minimum of five specimens from each of the warp and fill directions on materials of the same lot shall be tested and their results averaged (arithmetic mean).

** Only one specimen.

6. NOTES

(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)

6.1 Intended use. This standard contains requirements necessary to establish fire performance criteria and to provide a list of approved specifications for interior finish materials and furnishings to be used on Naval surface ships and submarines.

6.2 Acquisition requirements. Acquisition documents should specify the title, number, and date of this standard.

6.3 Subject term (key word) listing.

Ceiling products, acoustical Char Combustion Curtains Deck coverings Draperies Fire resistance Flame Flame spread Flashover Furniture Heat release Ignition Insulation, thermal Sheathing, bulkhead Sheathing, overhead Smoke

6.4 Change notations. The margins of this standard are marked with vertical lines to indicate modifications generated by this change. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations.

Custodian: Preparing activity:

Navy – SH Navy – SH (Project 19GP-2008-001)

Review activity:

Navy – YD

NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.daps.dla.mil/online.

File details come from the government source that posted it. Updated .