2010-04-19 MIL-STD-1623E(NAVY) w CHANGE 1.pdf
PDF 243 KB Posted
- Attached to
- Mattresses Federal contract opportunity
- Solicitation number
- 70Z04026Q60428Y00
About this file
This is a Department of Defense Design Criteria Standard (MIL-STD-1623E with Change 1, dated April 19, 2010) establishing fire performance requirements and approved specifications for interior finish materials and furnishings used on Naval surface ships and submarines.
The standard applies to bulkhead sheathing, overhead sheathing, furniture, draperies and curtains, deck coverings, insulation, and bedding applications. Table I specifies material requirements across these categories with corresponding fire tests and performance limits. For bulkhead and overhead sheathing, approved materials include high-pressure laminates, PVC film-aluminum laminates, and PVF film-aluminum laminates, all requiring ASTM E84 or UL 723 testing with flame spread indices not exceeding 25. Furniture requirements include vinyl upholstery, polychloroprene cushioning, and various laminate types tested to ASTM D6413 and ASTM E162 standards. Deck coverings encompass vinyl tiles, rubber tiles, vinyl sheets, terrazzo, latex mastic, and latex concrete, all requiring ASTM E648 testing with minimum critical radiant flux of 0.45 w/cm². Insulation materials include pipe insulation, insulating boards, insulating felts, glass cloth, cellular foam, and high-temperature fire/thermal/acoustic insulation tested per ASTM E84, ASTM E162, or 46 CFR 164.009 depending on material type. Bedding components including mattresses, cushioning, covers, and blankets must meet ASTM D6413 and NFPA 267 requirements. Section 5.2.1 mandates that manufacturers conduct all fire tests through independent laboratories accredited to ISO/IEC 17025 or equivalent by recognized bodies such as A2LA or IAS, with the Government reserving witness and testing rights. Change 1 modifications updated references to MIL-PRF-24667 for deck coatings, corrected insulating board requirements, and added MIL-STD-3020 for fire resistance test methods for N-Class divisions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FAR Clauses.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INCH-POUND
MIL-STD-1623E(NAVY)
w/CHANGE 1 19 April 2010
SUPERSEDING
MIL-STD-1623E(SH)
20 June 2006
DEPARTMENT OF DEFENSE
DESIGN CRITERIA STANDARD
FIRE PERFORMANCE REQUIREMENTS AND
APPROVED SPECIFICATIONS FOR INTERIOR
FINISH MATERIALS AND FURNISHINGS
(NAVAL SHIPBOARD USE)
AMSC N/A FSC 19GP
Source: https://assist.dla.mil -- Downloaded: 2015-11-05T20:46Z
Check the source to verify that this is the current version before use.
w/CHANGE 1
FOREWORD
1. This military standard is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense.
2. Comments, suggestions, or questions on this document should be addressed to Commander, Naval Sea Systems Command, ATTN: SEA 05S, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard, DC 20376- 5160 or emailed to commandstandards@navy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https://assist.daps.dla.mil/online .
ii https://assist.daps.dla.mil/online
SUMMARY OF CHANGE 1 MODIFICATIONS
1. The reference to MIL-PRF-17951 in table I, deck coverings, treads non-skid, was deleted and replaced with MIL-PRF-24667. MIL-PRF-17951 was cancelled and superseded by MIL-PRF-24667 on 8/7/2008.
2. The change to table I, insulating board, is proposed to correct an error. In the existing document, the requirement for MIL-I-742 core material, insulating board, Type I, was inadvertently mixed up with fire performance requirement for MIL-I-742 faced insulating board system (Type I). This error, if not corrected, could lead to mis-interpretation of acceptance criteria during qualification testing.
3. The reference to MIL-PRF-2818 in table I, insulating blanket, was deleted because there is no acceptable commercial specification readily available to replace it. Determining the suitable commercial replacement specification, or modifying an existing commercial specification to make it suitable for NAVSEA use, will require a significant amount of testing/tasking to establish compliance of a commercial specification with a variety of requirements typical of such a specification.
4. Added requirements for on-deck insulation to table I.
5. Replaced reference to MIL-PRF-32161 Appendix A with MIL-STD-3020 in table I, high temperature fire/thermal/acoustic insulation. MIL-STD-3020 is the new standard for all fire resistance test methods for N-Class divisions. Added MIL-STD-3020 to list of applicable documents in Section 2.
6. The following modifications to MIL-STD-1623E have been made:
Paragraph Modification
Foreword Changed
2.2.1 Changed
2.4 Changed
Table I Changed
6.4 Changed
iii
CONTENTS
PARAGRAPH PAGE
FOREWORD....................................................................................................................................................... ii Summary of change 1 modifications ................................................................................................................... iii
1. SCOPE
1.1 Scope 1
1.2 Applicability
1.3 Limitations
2. APPLICABLE DOCUMENTS
2.1 General
2.2 Government documents
2.2.1 Specifications, standards, and handbooks
2.2.2 Other Government documents, drawings, and publications
2.3 Non-Government publications
2.4 Order of precedence
3. DEFINITIONS
4. GENERAL REQUIREMENTS
5. DETAILED REQUIREMENTS
5.1 Materials
5.2 Fire test provisions
5.2.1 Responsibility for testing
5.2.2 Methods of testing
6. NOTES
6.1 Intended use
6.2 Acquisition requirements
6.3 Subject term (key word) listing
6.4 Change notations
TABLES
TABLE I. Material requirements TABLE II. Fire tests iv
1. SCOPE
1.1 Scope. This design criteria standard provides fire performance requirements and approved specifications for various categories of interior finish materials and furnishings for use on Naval surface ships and submarines.
1.2 Applicability. This design criteria standard applies to materials for bulkhead sheathing, overhead sheathing, furniture, draperies and curtains, deck coverings, insulation, and bedding applications. The fire performance requirements of this design criteria standard supersede those contained in the applicable specifications.
1.3 Limitations. Although the development of limits for toxic products of combustion is of major concern, the information generally available is not refined to the degree to allow inclusion of finite limits in this standard at this time. Components and materials not previously approved by the Navy will be evaluated for fire gas toxicity, off-gassing, health hazards, dermal irritation/sensitization, and other pertinent factors as determined by the Naval Technical Authority.
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this standard. This section does not include documents cited in other sections of this standard or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this standard, whether or not they are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.
FEDERAL SPECIFICATIONS
CCC-C-436 - Cloth, Ticking Twill, Cotton
L-P-1040 - Plastic Sheets and Strips (Polyvinyl Fluoride)
FEDERAL STANDARDS
FED-STD-191 - Textile Test Methods
FED-STD-501 - Floor Coverings, Resilient, Nontextile: Sampling and Testing
COMMERCIAL ITEM DESCRIPTIONS
A-A-52085 - Cloth, Drill, Cotton
A-A-55188 - Blankets, Bed, Wool, Shrink Resistant and Mothproofed
A-A-59502 - Plastic Sheet, Polycarbonate
A-A-59517 - Cloth, Coated or Laminated, Polyvinylchloride (Artificial Leather)
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-I-742 - Insulation Board, Thermal, Fibrous Glass
MIL-I-2781 - Insulation, Pipe, Thermal
MIL-PRF-2819 - Insulation Block, Thermal
MIL-D-3134 - Deck Covering Materials
MIL-PRF-3135 - Deck Covering Underlay Materials
- Matting or Sheet, Floor Covering Insulating for High Voltage Application MIL-DTL-15562
MIL-I-16411 - Insulation Felt, Thermal, Glass Fiber
MIL-P-17171 - Plastic, Laminate, Decorative, High Pressure
MIL-D-18873 - Deck Covering Magnesia Aggregate Mixture
MIL-C-20079 - Cloth, Glass; Tape, Textile Glass; and Thread, Glass
MIL-PRF-20092 - Rubber or Plastic Sheets and Assembled and Molded Shapes, Synthetic, Foam or Sponge Open Cell
MIL-A-21016 - Adhesive, Resilient Deck Covering
MIL-D-21631 - Deck Covering, Latex Concrete
MIL-I-22023 - Insulation Felt, Thermal and Sound Absorbing Felt, Fibrous Glass, Flexible
MIL-PRF-22344 - Insulation, Pipe, Thermal
MIL-C-22395 - Compound, End Sealing, Thermal Insulation Pipe Covering -Fire-, Water-, and Weather-Resistant
MIL-P-22581 - Plastic Tiles, Vibration Damping, Type III
MIL-A-23054 - Acoustical Absorptive Board, Fibrous Glass Perforated Fibrous Glass Cloth Faced
MIL-PRF-23653 - Plastic Tiles, Vibration Damping
MIL-PRF-24172 - Insulation, Plastic, Cellular Foam, Rigid, Preformed and Foam-in- Place
MIL-DTL-24191 - Plastic Sheet, Cell or Continuous Cast, Acrylic, Shipboard Application (Illumination and Signal Lighting)
MIL-C-24500 - Cloth, Drapery, Bunk Curtain, Slipcovers, and Labels, Fire Retardant
MIL-L-24518 - Laminate, Vinyl Film-Aluminum, Decorative
MIL-PRF-24613 - Deck Covering Materials, Interior, Cosmetic Polymeric
MIL-PRF-24667 - Coating System, Non-Skid, for Roll or Spray Application
DOD-I-24688 - Insulation Panel, Thermal and Acoustic Absorptive, Open-Cell Polyimide Foam
MIL-T-24708 - Thermal/Acoustic Insulation Barrier Material: Polyimide Foam
MIL-PRF-24712 - Coatings, Powder (Metric)
MIL-PRF-32161 - Insulation, High Temperature Fire Protection, Thermal and Acoustic
MIL-PRF-32170 - Deck Tiles, Wear-Resistant
MIL-PRF-32171 - Deck Coatings, High Durability
DEPARTMENT OF DEFENSE STANDARD
MIL-STD-3020 - Department of Defense Standard Practice for Fire Resistance of U.S.
Naval Surface Ships
(Copies of these documents are available online at https://assist.daps.dla.mil/online or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.
NAVAL SEA SYSTEMS COMMAND
NAVSEA 05Z6 PD 5-04A - Mattress, Innerspring, Flame-Resistant, Shipboard
(Copies of this document are available from the Commander, Naval Sea Systems Command, ATTN: SEA 05Z, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160).
CODE OF FEDERAL REGULATIONS (CFR)
46 CFR 164.009 - Noncombustible Materials for Merchant Vessels
(Copies of this document are available from the Superintendent of Documents, U.S. Government Printing Office, Washington DC 20401 or online at www.gpoaccess.gov/index.html.)
2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.
AMERICAN ASSOCIATION OF TEXTILE CHEMISTS AND COLORISTS (AATCC)
AATCC-135 - Dimensional Changes of Fabrics After Home Laundering
(Copies of this document are available from the American Association of Textile Chemists and Colorists, P.O. Box 12215, Research Triangle Park, NC 27709.)
ASTM INTERNATIONAL
ASTM D635 - Rate of Burning and/or Extent and Time of Burning of Self- Supporting Plastics in a Horizontal Position, Standard Test Method for
ASTM D6413 - Flame Resistance of Textiles (Vertical Test), Standard Test Method for
ASTM E84 - Surface Burning Characteristics of Building Materials
ASTM E162 - Surface Flammability of Materials Using a Radiant Heat Energy Source, Standard Test Method for
ASTM E648 - Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source, Standard Test Method for
ASTM E662 - Specific Optical Density of Smoke Generated by Solid Materials, Standard Test Method for
ASTM E1264 - Acoustical Ceiling Products, Standard Classification for
ASTM F1066 - Tile, Floor, Vinyl Composition, Standard Specification for
ASTM F1700 - Solid Vinyl Floor Tile, Standard Specification for
Source: https://assist.dla.mil -- Downloaded: 2015-11-05T20:46Z
Check the source to verify that this is the current version before use.
www.gpoaccess.gov/index.html
(Copies of these documents are available from ASTM International, 100 Barr Harbor Avenue, PO Box C700, West Conshohocken, PA, USA 19428-2959 or online at www.astm.org.)
ELECTRIC BOAT CORPORATION
EB Corp. Spec 4013 - Anti-Sweat and Refrigerant Insulation Systems (Sheets and Tubes)
(Copies of this document are available from Electric Boat Corporation, a General Dynamics Company, Department 447, Material Services, 75 Eastern Point Road, Groton, CT 06340-4899.)
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 267 - Fire Characteristics of Mattresses and Bedding Assemblies Exposed to Flaming Ignition Source
(Copies of this document are available from NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471 or online at www.nfpa.org.)
UNDERWRITERS LABORATORIES, INC. (UL)
UL 94 - Tests for Flammability of Plastic Materials
UL 723 - Test for Surface Burning Characteristics of Building Materials
(Copies of these documents are available from COMM 2000, 1414 Brook Drive, Downers Grove, IL 60515 or online at www.ul.com.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.
3. DEFINITIONS
This section is not applicable to this standard.
4. GENERAL REQUIREMENTS
This section is not applicable to this standard.
5. DETAILED REQUIREMENTS
5.1 Materials. Interior finish materials and furnishings shall meet the requirements set forth in table I.
Thickness for bulkhead sheathing, overhead sheathing, and furniture indicate maximum limits in both application and fire tests.
Check the source to verify that this is the current version before use.
http://www.astm.org/ http://www.nfpa.org/ http://www.ul.com/
TABLE I. Material requirements.
Category Material Specification Fire test Test limits Flame spread index 25 MAX High pressure laminate
MIL-P-17171,
Type IV
ASTM E84 or UL 723 15 MAX Smoke developed index
Flame spread index 25 MAX Fabric-backed vinyl Commercial ASTM E84 75 MAX Smoke developed index
0.035 inch
MAX
Vinyl thickness
Flame spread index 25 MAX Smoke developed index 75 MAX
PVC film-aluminum laminate
ASTM E84 or
UL 723
MIL-L-24518
0.011 inch
MAX
PVC film thickness
0.063 inch
MAX
Aluminum thickness
Flame spread index 25 MAX Smoke developed index 15 MAX
Bulkhead sheathing1 High pressure laminate pre-bonded to aluminum
ASTM E84 or
UL 723
MIL-P-17171 /
0.050 inch
MAX
Aluminum thickness
Flame spread index 25 MAX Smoke developed index 75 MAX
PVF film-aluminum laminate
PVF film thickness 0.004 inch
MAX
L-P-1040, Type II, Grade A, Class 1
ASTM E84 or
UL 723
0.063 inch
MAX
Aluminum thickness
9Plastic tile MIL-PRF- 23653
ASTM D635 /, 10/
9Plastic sheet MIL-P-22581 ASTM D635 /, 10/ Flame spread index 25 MAX ASTM E1264
Class A (all surfaces)
ASTM E84
Smoke developed index 50 MAX
Acoustical ceiling products
Class B (face side)
ASTM E84 Flame spread index 75 MAX
1.35 inch/minute
MAX
ASTM D635 Flame rate Acrylic light-diffusing panel/windows (lighting fixture only)
MIL-DTL-
24191
ASTM E66220/ Smoke density 50 MAX at
0.250 inch thickness
Overhead sheathing2/
Flame spread index 25 MAX Smoke developed index 35 MAX
Fibrous glass opaque suspended ceiling panel
Commercial ASTM E84
0.750 inch
MAX
Panel thickness
TABLE I. Material requirements – continued.
Flame spread index 25 MAX Smoke developed index 75 MAX
PVC film-aluminum laminate
ASTM E84 or
UL 723
MIL-L-24518
0.063 inch
MAX
Aluminum thickness
Flame spread index 25 MAX Smoke developed index 75 MAX
Overhead sheathing2 PVF film-aluminum laminate
PVF film thickness 0.004 inch
MAX
L-P-1040, Type II, Grade A, Class 1
ASTM E84 or
UL 723
continued
0.05 inch
MAX
Aluminum thickness
Char length 3 inch MAX After flame 2 sec MAX
A-A-59517, Class 4, Condition a
Vinyl upholstery ASTM D6413
Flaming droplets None Char length 3 inch MAX Upholstery fabric Commercial ASTM D6413 After flame 2 sec MAX Flaming droplets None
ASTM E162 Flame spread 10 MAX ASTM E66220/ Smoke density 200 MAX
Polychloroprene cushioning15
Net peak HRR 150 kW MAX
MIL-PRF-
20092, Type II, Class 5
Avg specific extinction area
300 m2/kg
MAX
MIL-PRF-
20092 Appendix A
Furniture
Burning droplets or flaming material19
None
Flame spread index 75 MAX Smoke developed index 50 MAX
High pressure laminate for table tops4
MIL-P-17171,
Type I
ASTM E84
0.062 inch
MAX
Laminate thickness
A-A-59502, Type II
Polycarbonate UL 94 Flammability V-0
Char length 3 inch MAX After flame 1 sec MAX
MIL-C-24500,
Type II13
Polyaramid/novoloid ASTM D6413
After glow 25 sec MAX ASTM E66220/ Smoke density 20 MAX
Char length 5 inch MAX After flame 1 sec MAX
MIL-C-24500,
Type I13
Polyaramid ASTM D6413
After glow 25 sec MAX
ASTM E66220/ Smoke density 20 MAX
Draperies and curtains5/
Char length 1.5 inch MAX Fibrous glass Commercial ASTM D6413 After flame 1 sec MAX After glow 2 sec MAX
ASTM E66220/ Smoke density 20 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux ASTM F1066 and ASTM F1700
Vinyl tile
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Fire-retardant plastic Commercial
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Vinyl sheet Commercial
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Rubber tile Commercial
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Vinyl tile or sheet with backing Commercial
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
Deck coverings7
ASTM E648 Critical radiant flux MIL-PRF- 24667
Treads non-skid
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux MIL-PRF-
24667 Epoxy non-skid
ASTM E66220/ Smoke density 450 MAX Char length 10 inch MAX Combustion time 4.0 minute
MAX
MIL-PRF-
FED-STD-501,
method 6411
Underlay
Ignition time7/ 20 sec MIN Char length 10 inch MAX Combustion time 4.0 minute
MAX
MIL-D-3134,
Type I, Class 1, Type I, Class 2
FED-STD-501,
method 6411
Terrazzo
Ignition time7/ 20 sec MIN Char length 10 inch MAX Combustion time 4.0 minute
MAX
MIL-D-3134,
Type II
FED-STD-501,
method 6411
Latex mastic
Ignition time7/ 20 sec MIN Char length 3 inch MAX Combustion time 4.0 minute
MAX
FED-STD-501,
method 6411
Latex concrete MIL-D-21631
Ignition time7/ 20 sec MIN
Char length 3 inch MAX Combustion time 4.0 minute
MAX
Magnesium aggregate
FED-STD-501,
method 6411
MIL-D-18873
Ignition time7/ 20 sec MIN
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Electrical grade mat or sheet
MIL-DTL-
155626/
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Carpet Commercial
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux MIL-PRF-
24667 Spray-on non-skid
ASTM E66220/ Smoke density 450 MAX
Deck coverings7
Flame spread 20 MAX continued
MIL-PRF-
24712
Powder coating ASTM E162 Dripping None
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Interior cosmetic polymeric
MIL-PRF-
24613
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Deck tiles, wear resistant
MIL-PRF-
32170
ASTM E66220/ Smoke density 450 MAX
0.45 w/cm2
MIN
ASTM E648 Critical radiant flux Deck coating, high durability
MIL-PRF-
32171
ASTM E66220/ Smoke density 450 MAX Flame spread index 25 MAX
Smoke developed index
15 MAX
MIL-I-742,
Type I
Insulating board ASTM E84
(faced board) 14/ Thickness
Pass8
Type I (Core only)
46 CFR 164.009 /
Pass8
Type II (unfaced board)
46 CFR 164.009 /
Insulation
Flame spread index 0 MAX Pipe insulation MIL-I-2781 ASTM E84 Smoke developed index
0 MAX
Flame spread index 25 MAX MIL-PRF- 22344
Pipe insulation ASTM E84 Smoke developed index
50 MAX
1 ft. on horizontal pipe runs
MAX
Flame spread Anti-sweat pipe insulation15
EB Corp Spec
Ignition of target array None
Room/corner test (see applicable specification, Appendix A)
Melting, dripping or flaming droplets
None
Heat release rate (material only)
11,384 Btu/minute (200 kW)
MAX
Flame spread index 0 MAX MIL-PRF-
Block insulation ASTM E84 Smoke developed index
0 MAX
Pass8Insulating felt MIL-I-16411 46 CFR 164.009 / 21Insulating blanket / 46 CFR 164.009 Pass8/
22On-deck insulation / 46 CFR 164.009 Pass8/ MIL-C-20079 (All tests before and after treatment) Type I, Classes 1, 3, 5, 7, 9
46 CFR 164.009 Pass8/ Insulation continued
Glass cloth
Flame spread index 20 MAX Type I, Class 2 ASTM E84 Smoke developed index
10 MAX
After flame and afterglow
0 sec MAX
Char length 0 inch MAX
Type I, Classes 4, 6, 8, ASTM D6413 or FED-STD- 191 Method 5903.2
Flame travel 1.5 inch MAX Pass8Type II, Classes 1, 3, 4
46 CFR 164.009 /
Flame spread index 20 MAX Type II, Class
ASTM E84
Smoke developed index
10 MAX
Flame spread index 25 MAX Smoke developed index
250 MAX
Cellular foam (Reefer spaces only)
MIL-PRF-
24172
ASTM E84
(before and after humid aging)
Foam thickness 1.0 inch MAX Melting, dripping, or flaming droplets
None
MIL-C-22395,
fire resistance
Burn after removal of a test flame
End sealer MIL-C-22395 30 sec MAX
Flame spread index 25 MAX MIL-I-22023 Type I and Type II
ASTM E84
Smoke developed index
50 MAX
Thermal/sound absorbing felt15/
MIL-I-22023
Appendix A
> 10 minute
MIN
Type III Flash-over time
ASTM E662 Smoke density 5 max Insulation continued DOD-I-24688, Type I DOD-I-24688 Appendix A
Flash-over time > 10 minute
MIN
Thermal/acoustic panel15/
Type II, Class 1 and 2
DOD-I-24688
Appendix A
> 10 minute
MIN
Flash-over time
Flame spread index 25 MAX MIL-PRF- 32161, Type I, II, and III
ASTM E84
Smoke developed index
50 MAX
High temperature fire/thermal/acoustic insulation15/
Type I MIL-STD-3020 Full-scale fire resistance test
Flame spread index12ASTM E162 / 25 MAX MIL-T-24708, Type I ASTM E66220/ Smoke density 150 MAX
Thermal/acoustic barrier15/
MIL-T-24708
Appendix
> 10 minute
MIN
Type I, Class 3 Flash-over time
Flame spread index 30 MAX ASTM E84 or
UL 723
Acoustic board MIL-A-23054 Smoke developed index
100 MAX
Component testing:
Upholstery Ticking, Border Ticking, Flange, Tape16/ and
Pocketing Material16/
NAVSEA
05Z6 PD 5-
04A
Mattress, innerspring
Initial flammability: ASTM D6413 Char length 5 inch MAX
Bedding
After flame 2 sec MAX Molten and/or flaming drops
None
Flammability after 15 launderings:
Char length 5 inch MAX
Mattress, innerspring continued
After flame 2 sec MAX
FED-STD-191
Method 5556 and ASTM D6413
Molten and/or flaming drops
None
NAVSEA
05Z6 PD 5-
04A continued
Cushioning and insulator pad Char length 5 inch MAX ASTM D6413 After flame 2 sec MAX Molten and/or flaming drops
None
Flame spread18ASTM E162 / 10 MAX Smoke density18/ 200 MAX ASTM E66220/ Molten and/or flaming drops
None
Finished mattress testing:
Net peak HRR 150 kW MAX Avg specific extinction area
300 m2/kg
MAX
NFPA 267 (with Navy exceptions)
Burning droplets or flaming material19
None
ASTM E162 Flame spread 10 MAX ASTM E66220/ Smoke density 200 MAX
Bedding continued
Mattress, polychloroprene15
Net peak HRR 150 kW MAX
MIL-PRF-
20092, Type II, Class 5
Avg specific extinction area
300 m2/kg
MAX
MIL-PRF-
20092 Appendix A
Burning droplets or flaming material19
None
Char length 5 inch MAX After flame 2 sec MAX
Treated cotton mattress ticking (non-launderable)3
CCC-C-436,
Type II, Class
ASTM D6413
Flaming droplets None Char length 5 inch MAX Mattress cover, cotton drill (launderable)3
A-A-52085, Type I, Class 2
ASTM D6413
After flame 2 sec MAX / Flame time 5 sec MAX Blanket17
Drip flame time 5 sec MAX
/ A-A-55188 Aircraft Material Fire Test Handbook , Chapter 18, Recommended Procedure for the 4-Ply Horizontal Flammability Test for Aircraft Blankets
Holing, flame penetration, or burn-through permitted
None
NOTES:
1/ Maximum test limits are based upon material bonded to a non-combustible substrate.
2/ Maximum test limits are based upon material attached to, or supported by, a non-combustible substrate.
3/ Use with polychloroprene mattress only.
4/ Wherever a flame spread index higher than 25 is indicated, the material is acceptable since there is no other acceptable material available with a lower flame spread index.
5/ An 8-ounce weight shall be used for materials tested in accordance with ASTM D6413.
6/ Cement test specimen with MIL-A-21016. Permit cement to dry a minimum of 72 hours before conducting fire test.
7/ Materials tested in accordance with method 6411 of FED-STD-501 shall exhibit ignition time no less than 20 seconds. Ignition time is defined as the time in seconds from the initial application of the burners on the sample until the first self-sustaining flame (ignition) is observed issuing from the top surface of the sample.
8/ Materials tested in accordance with 46 CFR 164.009 shall pass all requirements for noncombustibility.
9/ Specimen shall not burn to the 4-inch mark after the first or second ignition.
10/ No wire gauze shall be mounted beneath the specimen and only three (3) specimens cut from the same tile shall be tested. Each of the three (3) specimens shall pass. If any do not pass, the procedure in ASTM D635 which specifies tests in groups of ten (10) specimens (cut from the same tile) shall be followed.
11/ (a) The fire-containment assembly, with attached insulation, shall have withstood the fire endurance test without passage of flame for a time period equal to that for which the classification is desired, and (b) Transmission of heat through the assembly during the fire endurance test period shall not have raised the average temperature on its unexposed surface more than 250 °F (139 °C) above its initial temperature, nor the temperature of any one point on the surface, more than 325 °F (181 °C) above its initial temperature. The test shall be performed in both vertical and horizontal configurations.
12/ Type I shall be tested twice. One with the glass cloth cover facing the heat source, and one with the flexible polyimide foam facing the heat source.
13/ Material shall be tested as received and after five (5) launderings as per AATCC 135 Procedure IIIB in both warp and fill directions.
14/ Test at maximum thickness contemplated for use.
15/ Where test methods are non-standard, but are called out from within the specification or an Appendix to that specification, the test methods will be referenced as such.
16/ Only molten and/or flaming drops requirement applies to tape. Only initial flammability requirements apply to pocketing material.
17/ The A-A-55188 limits the use of blankets to wool material only. The fire performance requirements apply to alternative materials which are subject to approval by Naval Technical Authority.
18/ When materials are not identical on both sides, each side shall be tested as a different specimen (does not apply to cushioning).
19/ This means no flaming droplets or flaming material which fall from the test mattress during the fire test, shall continue flaming after reaching the test platform or floor.
20/ Where test method ASTM E662 is invoked, tests shall be conducted in both non-flaming and flaming modes.
21/ MIL-PRF-2818 has been cancelled without replacement. When this product is required, vendor/contractor shall submit recommended product specification to the Naval Technical Authority for approval prior to use.
22/ MIL-D-23134 has been inactivated. When this product is required, vendor/contractor shall submit recommended product specification to the Naval Technical Authority for approval prior to use.
5.2 Fire test provisions.
5.2.1 Responsibility for testing. Unless otherwise required in the applicable material specification, the manufacturer is responsible for conducting fire tests as specified herein. All tests specified in this document shall be conducted by an independent testing laboratory that is accredited to ISO/IEC 17025 or equivalent procedure.
Accreditation shall be obtained from a recognized accreditation body such as American Association for Laboratory Accreditation (A2LA) or International Code Council’s International Accreditation Services (IAS). The scope of accreditation shall include specific flammability and fire tests required for qualification. The Government reserves the right to witness the tests, and/or perform any of the tests set forth herein where such testing is deemed necessary to assure compliance to prescribed requirements.
5.2.2 Methods of testing. Fire tests shall be conducted on materials as specified in table I and the notes therein. All fire test procedures shall be in accordance with prescribed standards and test methods and, unless otherwise specified herein, no less than three specimens shall be tested on material of the same lot with results averaged (arithmetic means). Tests as listed in table II shall apply.
TABLE II. Fire tests.
Specification Description Surface flammability
ASTM D635 Burn rate test
ASTM E84 Tunnel test
ASTM E162 Radiant panel
ASTM E648 Flooring radiant panel
FED-STD-501,
Method 6411
Floor covering, fire resistance
UL 94 Flammability of plastics
Vertical flame resistance
ASTM D6413* Flame resistance of textiles
Smoke generation
ASTM E84 Tunnel test
ASTM E662 Specific optical density of smoke
Test for noncombustibility
46 CFR 164.009 Heated tube test
Fire endurance
NFPA 267** Fire characteristics of mattresses
UL 1709** Hydrocarbon pool fire exposure test
* A minimum of five specimens from each of the warp and fill directions on materials of the same lot shall be tested and their results averaged (arithmetic mean).
** Only one specimen.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Intended use. This standard contains requirements necessary to establish fire performance criteria and to provide a list of approved specifications for interior finish materials and furnishings to be used on Naval surface ships and submarines.
6.2 Acquisition requirements. Acquisition documents should specify the title, number, and date of this standard.
6.3 Subject term (key word) listing.
Ceiling products, acoustical Char Combustion Curtains Deck coverings Draperies Fire resistance Flame Flame spread Flashover Furniture Heat release Ignition Insulation, thermal Sheathing, bulkhead Sheathing, overhead Smoke
6.4 Change notations. The margins of this standard are marked with vertical lines to indicate modifications generated by this change. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations.
Custodian: Preparing activity:
Navy – SH Navy – SH (Project 19GP-2008-001)
Review activity:
Navy – YD
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.daps.dla.mil/online.
File details come from the government source that posted it. Updated .