2-Step Salient Characteristics.pdf

PDF 64 KB Posted

Attached to
2-Step Multiview Positioning Platform for Carl R. Darnall Army Medical Center (CRDAMC), Fort Hood, TX
Solicitation number
W81K0026QA074
Issued by

About this file

This document is an Equipment Technical Specifications sheet for medical imaging equipment. The specifications establish the requirements for equipment that must integrate with GE XR650 and GE AMX700 imaging systems. The equipment must have a minimum weight capacity of 500 lbs. to accommodate diverse patient populations and be constructed from non-porous materials to facilitate cleaning and sanitation in clinical environments.

The equipment must incorporate specific design features to enhance operational efficiency and patient safety. Key requirements include four or more placement locations for imaging panels to support versatile radiographic positioning, a design that minimizes patient repositioning to improve comfort and workflow, at least two integrated grab bars for patient stability and fall prevention, and integrated casters for transport and maneuverability within clinical settings. The specified dimensional footprint is approximately 30.5" (Width) × 31.5" (Length) × 49.5" (Height). These specifications ensure seamless integration with existing imaging systems while prioritizing patient safety, operational flexibility, and ease of maintenance in healthcare facilities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Equipment Technical Specifications

To ensure seamless integration and optimal performance, the required equipment must meet the following criteria:

• System Compatibility: Must be fully compatible with GE XR650 and GE AMX700 imaging systems.

• Weight Capacity: A minimum weight capacity of 500 lbs. is required to accommodate a broad range of patients.

• Patient Handling: The design must minimize the need for patient repositioning, thereby enhancing comfort and workflow efficiency.

• Imaging Flexibility: The unit must provide four or more placement locations for imaging panels to ensure versatile radiographic positioning.

• Safety Features: To enhance patient stability and minimize fall risk, the equipment must be fitted with at least two integrated grab bars.

• Mobility: Integrated casters are required for effortless transport and maneuverability within the clinical environment.

• Material Composition: Must be constructed from non-porous materials to allow for easy and effective cleaning and sanitation.

• Dimensional Footprint: The equipment's dimensions should be approximately 30.5” (Width) x 31.5” (Length) x 49.5” (Height).

File details come from the government source that posted it. Updated .