2-Plans-LaRockConcession.pdf
PDF 11 MB Posted
- Solicitation number
- Not on record
- Issued by
- Luzerne County, Pennsylvania
About this file
This file contains construction plans for a new concession stand facility at Joe LaRock Recreation Field in Sugarloaf Township, Pennsylvania. The project involves the demolition of an existing concession stand and construction of a replacement structure in the same location, including temporary relocation of site features and limited site work to restore stone finishes. The contract is structured as a multi-prime agreement encompassing General Building Construction, Plumbing, Electrical, and Mechanical trades. Sealed bids are due by 4:00 PM prevailing time on Wednesday, October 28, 2026, through the PennBid Program, with bidding documents available beginning October 7, 2026. A non-mandatory pre-bid meeting is scheduled for 9:00 AM on Tuesday, October 13, 2026, at the project site. Questions must be submitted through PennBid's messaging system by 3:00 PM on Friday, October 23, 2026. Bids will be opened immediately following the due date and time at the Engineer's Office.
Bidders are required to submit a bid bond with corporate surety authorized in Pennsylvania equal to 10 percent of the total bid amount. The successful bidder must furnish a Performance and Payment Bond in the amount of 100 percent of the contract value. Prevailing wage rates apply to this project. An abstract of all bids received will be posted on PennBid following the bid deadline to allow prospective bidders to review submitted proposals. The contract will be awarded by Sugarloaf Township following the Engineer's recommendation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-Contract Documents and Specifications-LaRockConcession.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Plans
CONTRACTOR SHALL VERIFY ALL CONDITIONS
AND DIMENSIONS FOR THE ENTIRE PROJECT
BEFORE PROCEEDING WITH THE WORK.
CONTROL JOINT NOTE:
SLAB-ON-GRADE CONTROL JOINT SPACING AND LOCATIONS SHALL BE
COORDINATED WITH ARCHITECTURAL DRAWINGS AND
SPECIFICATIONS. A PLAN LAYOUT SHALL BE SUBMITTED TO THE
ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION.
N
NOTES:
1. SEE CHART BELOW FOR FINISH FLOOR ELEVATION AND SLAB CONSTRUCTION
T.F. ***.**'
T.P. ***.**'
Step Footing Marker
Top of Pier Marker
Top of Footing Marker
Pier Size Marker
Column Footing Size Marker
Foundation Wall Size Marker
P**
W**
Foundation Wall Footing Size Marker
F*.*
WF****
Foundation Symbol Legend
T.W. ***.**' Top of Wall Marker
Transition from Standard Footing to Trench Footing Marker
Rectangular Pier Size Marker RP**
Combined Column Footing Size Marker CF*.*
Retaining Wall Footing Marker RW-*
S3.0
S3.0
WF1224
MFW12
M F
W
W F
MFW12
WF1224
M F
W
W F
FROST WALL
SEE "TYPICAL
FROST WALL"
DETAIL
FROST WALL
SEE "TYPICAL
FROST WALL"
DETAIL
FROST WALL
SEE "TYPICAL
FROST WALL"
DETAIL
WF1224
MFW12
M F
W
W F
24 M
F W
W F
M F
W
W F
F3.0
MP1616
MP1616
F3.0
A
T.F. 96.00'
T.F. 96.00'
T.F. 96.00'T.F . 9
6.
T.F. 96.00' T.
F.
6.
T.F. 96.00'
T.F. 96.00'
T.F. 96.00'
T .F
.0
T.P. 100.00'
T.P. 100.00'
S3.0
S3.0
WRT @ 24" o.c.
L1
L2L2L2 L2
L2L2L2L2L2 L1
L2 L2 L2 L2
MLW8
M W
MLW8
M W
MW8
M
W
M W
M W
A
MP1616
MP1616
(3) 1.75x11.25 LVL
(3) 1.75x11.25 LVL
N
NOTES:
1.
2. MAXIMUM ROOF JOIST SPACING 2'-0" U.N.O.
3. ALL WOOD-TO-WOOD CONNECTIONS TO BE MADE WITH APPLICABLE SIMPSON PRODUCT OR EQUAL.
4. ROOF CONSTRUCTION 3/4" PLYWOOD.
5. ROOF JOISTS TO SATISFY 3/4" TOTAL DEFLECTION & 3/8" SNOW DEFLECTION.
TYPE
SLAB
REINFORCING FINISH FLOOR
4" Concrete 66-W2.9xW2.9 100'-0"
5" Concrete 44-W4.0xW4.0 100'-0"
DSGN:
JOB:
CHK:
DRAWN: APPRD:
DATE:
SCALE:
P MGR:
COPYRIGHT 2026
SHEET:
F
IL
E N
A M
E
R E
V
IS
IO
N
S D
A T
E
A ut od es k D oc s:
//3
.0
1_ S ug ar lo af
T w p_
L ar oc k_
F ie ld
C o nc e ss io n/
1_ S tr uc t_ S ug ar lo a f- T w p
_L ar o ck
_C o nc es si on
R
.r vt
As indicated
RPK
LRW10/02/26
329526.001
/0
/2
S1.0
RCS
RCS
F ou nd at io n a nd
F ra m in g P la n
N E
W C
O N
C E
S S
IO
N
S T
A N
D
K E
L
LE
R S
R O
A D
, D R
U M
S ,P
A
JO
E
L aR
O C
K R
E C
R E
A T
IO
N
F
IE
LD
LU
Z
E R
N E
C O
U N
T Y
, P A
Is su e d fo r
B id
TK
SCALE: 1/4" = 1'-0"
Foundation Plan
SCALE: 1/4" = 1'-0"
Roof Framing Plan
Schedule - Lintel
MARK TYPE
L1 W8x10 w/ CONT 3/8" x 0'-7" PL L2 (2) 3 1/2x3 1/2x5/16
TYPE
MAX. FRAMING
SPACING (U.N.O.)
3/4" Plywood 24" o.c.
ROOF TOW ELEVATION (U.N.O.): 110'-11"
NOTE:
PROVIDE MP16 AT EA END OF LINTEL (TYP).
GENERAL NOTES:
1. SLOPE ALL EXTERIOR SLABS 2% FROM
BUILDING WALLS.
2. ALL EXTERIOR SLABS TO HAVE A BROOMED
FINISH WITH TOOLED EDGES.
3. FOUNDATION WALL BELOW GRADE TO
HAVE CEMENT PARAGE COAT AND LIQUID
RUBBER FOUNDATION SEALANT FINISH.
4. PROVIDE A 15MIL VAPOR BARRIER BELOW
ALL INTERIOR CONCRETE SLABS.
rsotak Stamp
DESIGN LOADS:
ROOF LIVE LOAD 20 PSF
ROOF 25 PSF
SEISMIC IMPORTANCE FACTOR (Ie) 1.0
ADDITIONAL NOTES:
a. THE CONTRACTOR IS CAUTIONED AS TO NOT STORE ANY
CONSTRUCTION MATERIALS OR UNDERTAKE ANY CONSTRUCTION
OPERATION WILL EXCEED THE DESIGN LIVE LOAD CAPACITIES NOTED.
b. THE STRUCTURE HAS BEEN DESIGNED FOR THE DEAD AND LIVE
LOADS INDICATED ABOVE, ANY INCREASE OF LOADS DUE TO CHANGE
IN USAGE OR CONSTRUCTION MATERIALS, ETC. SHALL HAVE THE
WRITTEN APPROVAL OF THE ENGINEER.
c. THE STABILITY OF THE STRUCTURE IS DEPENDENT UPON THE
DIAPHRAGM ACTION OF THE ROOFS. THE CONTRACTOR IS
COMPLETELY RESPONSIBLE FOR THE METHODS OF CONSTRUCTION
AND SHALL PROVIDE ALL GUYS, BRACING AND SHORING REQUIRED TO
ACCOMMODATE ALL INTERIM LOADING CONDITIONS THROUGHOUT
THE CONSTRUCTION PHASE.
d. WEIGHT OF EQUIPMENT SHOWN ON THE STRUCTURAL DRAWINGS
HAVE BEEN CONSIDERED IN THE DESIGN OF THE FRAMING. ANY
ADDITIONAL EQUIPMENT NOT SHOWN ON THE STRUCTURAL
DRAWINGS AND EXCEEDING 300 POUNDS SHALL BE BROUGHT TO THE
ATTENTION OF THE ENGINEER FOR APPROVAL PRIOR TO
INSTALLATION.
GOVERNING DESIGN CODE
2021 INTERNATIONAL BUILDING CODE
ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
BUILDING RISK CATEGORY
DESIGN ROOF LIVE LOADS
DESIGN DEAD LOADS - NOT INCL. STRUCTURE SELF WEIGHT
SEISMIC DESIGN DATA
DESIGN WIND LOAD PARAMETERS
GROUND SNOW LOAD (Pg) 40 PSF
DESIGN ROOF SNOW LOADS
FLAT ROOF SNOW LOAD (Pf) 35 PSF
SNOW EXPOSURE FACTOR (Ce) 1.0
SNOW LOAD IMPORTANCE FACTOR (Is) 1.00
THERMAL FACTOR (Ct) 1.2
SNOW DRIFT SEE DIAGRAM
UNBALANCED ROOF SNOW LOADS
ROOF SLOPE FACTOR (Cs) 1.0
SLOPED ROOF SNOW LOAD 35 PSF
WINDWARD SNOW LOAD 40 PSF
LEEWARD SNOW LOAD EXTENDING X'-X" FROM RIDGE N/A
II
LEEWARD SNOW LOAD X'-X" FROM RIDGE EXTENDING TO EAVE N/A
MINIMUM UNIFORM DESIGN SNOW LOAD (NOT REDUCIBLE) 30 PSF
ULTIMATE DESIGN WIND SPEED (Vult) 112 MPH
ALLOWABLE STRESS DESIGN WIND SPEED (Vasd) 87 MPH
INTERNAL PRESSURE COEFFICIENT +/- 0.18
WIND EXPOSURE CATEGORY - PLAN WEST-EAST B
MAPPED SPECTRAL ACCELERATION (Ss)
MAPPED SPECTRAL ACCELERATION (S1)
SITE CLASS
DESIGN SPECTRAL RESPONSE COEFF. (Sds)
DESIGN SPECTRAL RESPONSE COEFF. (Sd1)
SEISMIC DESIGN CATEGORY
PLAN NORTH-SOUTH DIRECTION
SEISMIC FORCE RESISTING SYSTEM
DESIGN BASE SHEAR (V)
0.122
0.044
D
0.13
0.07
B
ORDINARY REINFORCED
MASONRY SHEAR WALLS
8.9 KIPS
ANALYSIS PROCEDURE EQUIV. LATERAL FORCE
RESPONSE MODIFICATION COEFF. (R) 3.0
SEISMIC RESPONSE COEFF. (Cs) 0.043
PLAN WEST-EAST DIRECTION
SEISMIC FORCE RESISTING SYSTEM
DESIGN BASE SHEAR (V) 8.9 KIPS
RESPONSE MODIFICATION COEFF. (R) 3.0
SEISMIC RESPONSE COEFF. (Cs) 0.043
WIND EXPOSURE CATEGORY - PLAN NORTH-SOUTH B
ROOF RAIN LOADS
INTENSITY (i) 3.0 IN/HR
ORDINARY REINFORCED
MASONRY SHEAR WALLS
GENERAL NOTES
1. THE CONTRACTOR IS ADVISED THAT ALL PLANS, DIMENSIONS, AND DETAILS DEPICT
FIELD CONDITION AS SHOWN. MINOR VARIATIONS ARE TO BE EXPECTED AND ANY
DEVIATIONS FROM THE CONTRACT DOCUMENTS SHALL BE APPROVED BY THE
ARCHITECT IN WRITING PRIOR TO PROCEEDING.
2. THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS AND
ELEVATIONS OF EXISTING WORK PRIOR TO FABRICATION OF ANY NEW MATERIALS.
IF THE EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF THE
WORK IN ACCORDANCE WITH THE DETAILS SHOWN, THE CONTRACTOR SHALL
NOTIFY THE ENGINEER IMMEDIATELY AND PROVIDE A SKETCH OF THE CONDITION
WITH THEIR PROPOSED MODIFICATION OF THE DETAILS GIVEN ON THE CONTRACT
DOCUMENTS. DO NOT COMMENCE WORK UNTIL CONDITION IS RESOLVED AND
MODIFICATION IS APPROVED BY THE ENGINEER.
3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE LOCATION OF
UTILITIES IN THE IMMEDIATE VICINITY OF CONSTRUCTION SO AS TO PREVENT
DAMAGE TO THEM. SHOULD DAMAGE TO SUCH UTILITIES OCCUR, THE CONTRACTOR
SHALL BE REQUIRED TO REPAIR SUCH DAMAGE AT THEIR OWN EXPENSE AND TO
THE SATISFACTION OF THE OWNER.
4. SHOP DRAWINGS FOR ALL STRUCTURAL ELEMENTS SHOWN ON THE CONTRACT
DOCUMENTS MUST BE SUBMITTED BY THE GENERAL CONTRACTOR AND REVIEWED
BY THE ENGINEER. IF THE CONTRACTOR OR OWNER FAILS TO OBTAIN ENGINEER'S
REVIEW OF THE SHOP DRAWINGS, THE ENGINEER WILL NOT BE RESPONSIBLE FOR
THE STRUCTURAL CERTIFICATION AND DESIGN OF THE PROJECT. SHOP DRAWINGS
ARE REVIEWED BY THE ENGINEER AS A CONVENIENCE TO THE GENERAL
CONTRACTOR AND ARE NOT A CONTRACT DOCUMENT.
5. LOADS GREATER THAN THE DESIGN LIVE LOADS SHALL NOT BE PLACED ON THE
STRUCTURE. A CONCRETE STRUCTURE MAY NOT SUPPORT IT'S DESIGN LIVE LOAD
FOR 28 DAYS. CONTRACTOR SHALL SUPPORT ADJACENT STRUCTURES, UTILITIES,
AND EXCAVATIONS AS REQUIRED. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS
FOR ALL TEMPORARY FORM WORK, SHEETING, SHORING AND UNDERPINNING
SEALED BY A PROFESSIONAL ENGINEER AS A PART OF THE CONTRACTOR'S WORK.
6. THE CONTRACTOR SHALL CONSULT THE ARCHITECTURAL, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR THE QUANTITY, LOCATION, AND DIMENSION OF HOLES
THROUGH FLOOR AND ROOF: CHASES, INSERTS, OPENINGS, SLEEVES, WASHERS,
DRIPS, REVEALS, DEPRESSIONS AND OTHER PROJECT REQUIREMENTS. REFER TO
ARCHITECTURAL DRAWINGS FOR THE FOLLOWING INFORMATION:
a. LOCATION AND THICKNESS OF MASONRY PARTITIONS
b. FULL EXTENT OF MASONRY INFILL AREAS
c. LOCATION AND THICKNESS OF STUD PARTITIONS
d. LOCATION AND SIZE OF WINDOWS, DOORS AND WALL OPENINGS
e. STAIRS, FLOOR AND WALL FINISHES
f. DETAIL DIMENSIONS AND SECTION DETAILS AS REQUIRED
7. THIS STRUCTURE HAS BEEN DESIGNED TO BE SELF-SUPPORTING AND STABLE
AFTER THE CONSTRUCTION OF THE BUILDING IS TO BE COMPLETED. THE STABILITY
OF THE STRUCTURE PRIOR TO COMPLETION IS SOLELY THE RESPONSIBILITY OF
THE CONTRACTOR. THIS RESPONSIBILITY EXTENDS TO ALL RELATED ASPECTS OF
THE CONSTRUCTION ACTIVITY INCLUDING, BUT NOT LIMITED TO, ERECTION
METHODS, ERECTION SEQUENCE, TEMPORARY BRACING, FORMS, SHORING, USE OF
EQUIPMENT AND SIMILAR CONSTRUCTION PROCEDURES.
8. THE CONTRACTOR SHALL BE RESPONSIBLE TO DETERMINE ALLOWABLE
CONSTRUCTION LOADS AND TO PROVIDE DESIGN AND CONSTRUCTION OF
FALSEWORK, FORMWORK, STAGING, BRACING, SHEETING, SHORING, AND
UNDERPINNING AS NECESSARY TO PREVENT ANY LATERAL OR VERTICAL
MOVEMENTS TO, AND TO INSURE THE STRUCTURAL INTEGRITY OF EXISTING
BUILDINGS, STREETS, AND ANY EXISTING UTILITY LINES.
9. BRACING, SHEETING, SHORING, ETC., REQUIRED TO INSURE THE STRUCTURAL
INTEGRITY OF THE EXISTING BUILDINGS OR NEW CONSTRUCTION, SIDEWALKS,
UTILITIES ETC., SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER ENGAGED BY
THE CONTRACTOR. DETAILED SIGNED AND SEALED SHOP DRAWINGS SHALL BE
PREPARED INDICATING ALL WORK TO BE PERFORMED. SUBMIT THE SHOP
DRAWINGS IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS.
SHOP DRAWINGS
1. DUPLICATION/PHOTOCOPYING OF THESE STRUCTURAL DRAWINGS SHALL NOT BE
PERMITTED FOR SHOP DRAWINGS. THIS INCLUDES PARTIAL AND/OR COMPLETE
DUPLICATION OF PLAN SHEETS AS BACKGROUNDS FOR SHOP DRAWINGS. ALL
SECTIONS INCLUDED IN THESE CONTRACT DRAWINGS MAY NOT BE
DUPLICATED/PHOTOCOPIED ON ANY SHOP DRAWINGS.
2. ORIGINAL SHOP DRAWINGS SHALL BE SUBMITTED FOR THE ARCHITECT/ENGINEER
REVIEW FOR THE FOLLOWING ITEMS AND AS PER THE SPECIFICATIONS:
a. CONCRETE AND MASONRY REINFORCING
b. SLAB ON GRADE CONTROL JOINT LAYOUT
c. CONCRETE MIX DESIGNS
• FOUNDATIONS
• RETAINING WALLS
• SLAB ON GRADE LISTING FIBER MESH REINFORCEMENT & DOSAGE RATE
d. MASONRY CERTIFICATIONS AND GROUT DESIGN
3. CONTRACTOR SHALL SUBMIT, FOR REVIEW, DRAWINGS AND CALCULATIONS FOR
ALL PERFORMANCE ASSEMBLIES IDENTIFIED IN THE GENERAL NOTES AND SPECIFIC
MATERIAL NOTES AS WELL AS LISTED BELOW: THE DESIGN OF THESE ASSEMBLIES
IS THE RESPONSIBILITY OF THE CONTRACTOR'S ENGINEER REGISTERED IN THE
PROJECT'S JURISDICTION. ALL SUBMITTALS SHALL BEAR THIS ENGINEER'S SEAL
AND SIGNATURE. REVIEW SHALL BE FOR GENERAL CONFORMANCE WITH THE
PROJECT REQUIREMENTS AS INDICATED ON THE DRAWINGS AND IN THE GENERAL
NOTES.
A.F.F. Above Finish Floor BCX Bottom Chord Extension B.O.F. Bottom of Footing B.S. Brick Shelf Elevation (plans) B.S. Both Sides (sections) CANT. Cantilever CJ Control Joints CL Center Line CMU Concrete Masonry Units CONT. Continuous DIA. Diameter DBA Deformed Bar Anchor E.E. Each End E.F. Each Face E.S. Each Side E.W. Each Way EXIST Existing F.F. Finish Floor F.S. Flat Strap GA Gage GT Girder Truss GALV Galvanized H# Header HORIZ Horizontal HSS Hollow Structural Section L Angle LG Long LLH Long Leg Horizontal
ABBREVIATION LIST
LLV Long Leg Vertical LSH Long Side Horizontal LSV Long Side Vertical N.T.S. Not To Scale o.c. On Center PL Plate PT Pressure Treated Wood REINF. Reinforcing REM. To Remain S.F. Step Footing STIFF PL Stiffener Plate T# Wood Truss T.B.R. To Be Removed T&B Top and Bottom T.F. Top of Footing T.O.S. Top of Steel T.O.W. Top of Wall T.P. Top of Pier TYP Typical U.N.O. Unless Noted Otherwise VERT. Vertical V.I.F. Verify In Field WFT Wood Floor Truss WGT Wood Girder Truss WHT Wood Hip Truss WRT Wood Roof Truss WWF Welded Wire Fabric XE Extended End - Type R
CONTRACTOR NOTE
CONCRETE WALL SHALL BE IN PLACE A MINIMUM OF 14 DAYS
BEFORE BACKFILLING. AT CONTRACTOR'S OPTION, BACKFILL MAY
BE PLACED AGAINST WALL THAT HAS BEEN TEMPORARILY SHORED;
HOWEVER, CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING
ANY MOVEMENT OF WALL DUE TO BACKFILLING.
FOUNDATIONS AND BACKFILL
1. SOIL BEARING CAPACITY OF 2,000 PSF WAS UTILIZED IN THE DESIGN OF THE
FOUNDATION SYSTEM.
2. SLAB ON GRADE DESIGN BASED ON MODULUS OF SUBGRADE REACTION OF 100 PCI.
3. PLACE EXTERIOR FOOTINGS AND FROST WALLS EXPOSED TO WEATHER AT LEAST
48" BELOW THE ADJACENT OUTSIDE FINISHED GRADE TO PROTECT FROM FROST
DAMAGE.
4. THE OWNER SHALL ENGAGE THE SERVICES OF A REGISTERED PROFESSIONAL
GEOTECHNICAL ENGINEER TO MONITOR AND INSPECT ALL EARTH WORK AND TO
PERFORM THE SPECIAL INSPECTIONS REQUIRED BY THE SCHEDULE OF SPECIAL
INSPECTIONS. THE GEOTECHNICAL ENGINEER SHALL SUPERVISE THE PLACING OF
THE COMPACTED FILL AND ALL THE MATERIALS AND EQUIPMENT USED FOR THIS
PURPOSE. THE GEOTECHNICAL ENGINEER SHALL CERTIFY, BY SEAL AND
SIGNATURE, THAT THE EARTH-WORK IS IN ACCORDANCE WITH THE GEOTECHNICAL
REPORT, PLANS AND SPECIFICATIONS.
5. THE SUB-FLOOR MATERIALS SHALL CONSIST OF AT LEAST FOUR TO SIX INCHES OF
GRAVEL OR CRUSHED STONE. THE SUB-FLOOR MATERIALS SHALL BE COMPACTED
BY AT LEAST FOUR COVERAGES OF A HEAVY-DUTY VIBRATORY ROLLER OR UNTIL
NO FURTHER COMPACTION IS OBSERVED. SEE THE DRAWINGS AND
SPECIFICATIONS FOR THE VAPOR BARRIER SIZE, TYPE AND LOCATION.
6. PRIOR TO CONCRETE PLACEMENT THE FOUNDATION BOTTOM SHALL BE
COMPACTED USING A WALK BEHIND VIBRATORY ROLLER OR GAS-POWERED
TAMPER.
7. IF SOIL OF THE BEARING CAPACITY NOTED ABOVE IS NOT ENCOUNTERED AT THE
ELEVATIONS SHOWN ON PLAN, UNSUITABLE SOILS SHALL BE REMOVED AND
REPLACED WITH STRUCTURAL FILL IN ACCORDANCE WITH THE GEOTECHNICAL
ENGINEER'S DIRECTION.
8. IF BEDROCK IS ENCOUNTERED AT OR ABOVE FOUNDATION SUBGRADE ELEVATION,
THE BEDROCK SURFACE SHALL BE OVER EXCAVATED A MINIMUM OF SIX INCHES
AND BACKFILLED WITH CRUSHED STONE TO THE SUBGRADE ELEVATION.
9. THE GEOTECHNICAL ENGINEER SHALL APPROVE SAMPLES OF ALL CONTRACTOR
PROPOSED COMPACTED FILL MATERIAL. IMPORTED STRUCTURAL FILL SHALL BE
FREE OF ORGANIC MATTER, ASH, CINDERS AND DEMOLITION DEBRIS.
10. CONTROL OF MOISTURE FOR PLACING FILL WILL BE BASED ON THE RESULTS OF
ASTM D-1557 MODIFIED PROCTOR TESTS.
11. ALL COMPACTED FILL SHALL HAVE A DENSITY OF AT LEAST 98% OF MAXIMUM DRY
DENSITY AS DETERMINED BY THE ASTM D-1557 MODIFIED PROCTOR TEST. PLACING
OF FILL WITH MOISTURE CONTENT OUTSIDE THE LIMITS FOR PROPER COMPACTION
SHALL NOT BE PERMITTED.
12. THE EXISTING SUBGRADE IN ALL FILL AND CUT AREAS SHALL BE COMPACTED TO A
FIRM, STABLE CONDITION AS DETERMINED BY THE GEOTECHNICAL ENGINEER,
PRIOR TO PLACEMENT OF FILLS AND EXCAVATION FOR FOOTINGS.
13. FILL MATERIAL SHALL BE PLACED IN LOOSE LIFTS NOT EXCEEDING 8" IN THICKNESS
AND SHALL BE MIXED, SPREAD, AND PLACED IN SUCH A WAY AS TO PRODUCE A
UNIFORM THICKNESS OF MATERIAL AFTER PLACING.
14. EACH LAYER OF FILL MATERIAL SHALL BE COMPACTED ON ALL PORTIONS OF THE
SURFACE OF EACH LIFT OF FILL BY RUBBER TIRE ROLLERS, SHEEP'S FOOT
ROLLERS, VIBRATORY ROLLERS, ETC. AS NECESSARY TO ATTAIN THE MAXIMUM DRY
DENSITY NOTED ABOVE AND AS APPROVED BY THE GEOTECHNICAL ENGINEER.
15. WHENEVER IN PLACE DENSITIES ARE FOUND TO BE BELOW LIMITS ACCEPTABLE TO
THE GEOTECHNICAL ENGINEER, ADDITIONAL ROLLING TO PRODUCE THE SPECIFIED
DENSITIES SHALL BE REQUIRED.
16. PLACING OF FILL WHEN FREE WATER IS STANDING ON THE EXISTING SURFACE
SHALL NOT BE PERMITTED.
17. PLACING OF FILL IN A FROZEN CONDITION OR ON TOP OF FROZEN MATERIAL SHALL
NOT BE PERMITTED.
18. SUBGRADE SUITABILITY SHALL BE VERIFIED BY GEOTECHNICAL ENGINEER WITHIN
24 HOURS PRIOR TO PLACING CONCRETE FOUNDATIONS AND CONCRETE SLABS ON
GRADE TO CONFIRM THAT NO DETERIORATION HAS OCCURRED SUBSEQUENT TO
TESTING PERFORMED AT TIME OF FILL PLACEMENT. UNSUITABLE CONDITIONS
SHALL BE CORRECTED PER GEOTECHNICAL ENGINEER'S RECOMMENDATION.
19. EXCAVATIONS SHOULD BE BACKFILLED OR HAVE CONCRETE PLACED AS SOON AS
POSSIBLE DURING CONSTRUCTION TO MINIMIZE ADVERSE AFFECTS TO SUBGRADE
CONDITIONS. GRADING DEPRESSIONS SHOULD BE AVOIDED.
20. WATER SHALL BE PREVENTED FROM ENTERING OPEN EXCAVATIONS. ANY
ACCUMULATED WATER SHALL BE REMOVED AS SOON AS POSSIBLE. IT IS
RECOMMENDED THAT CONCRETE BE PLACED THE SAME DAY THE EXCAVATION IS
MADE.
21. THE CONTRACTOR SHALL PROVIDE FOR DEWATERING AS REQUIRED DURING
EXCAVATION AND CONSTRUCTION.
CONCRETE
1. ALL WORK SHALL CONFORM TO THE "SPECIFICATIONS FOR STRUCTURAL
CONCRETE" (AMERICAN CONCRETE INSTITUTE, ACI 301) AND THE "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318), LATEST EDITIONS, UNLESS
NOTED OTHERWISE IN THE DRAWINGS OR PROJECT SPECIFICATIONS.
2. CONSTRUCTION TOLERANCES SHALL CONFORM TO THE "SPECIFICATION FOR
TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS" (ACI 117), LATEST
EDITION.
3. SHOP DRAWINGS SHALL BE PREPARED IN ACCORDANCE WITH THE "GUIDE TO
PRESENTING REINFORCING STEEL DESIGN DETAILS" (ACI 315) AND THE "ACI
DETAILING MANUAL" (SP-066), LATEST EDITIONS.
4. CONCRETE MATERIALS SHALL BE PROVIDED IN ACCORDANCE WITH THE
FOLLOWING SPECIFICATIONS:
• PORTLAND CEMENT ASTM C150
• HYDRAULIC CEMENT ASTM C1157
• FLY ASH AND NATURAL POZZOLAN ASTM C618
• SLAG CEMENT ASTM C989
• SILICA FUME ASTM C1240
• NORMAL WEIGHT AGGREGATE ASTM C33
• LIGHTWEIGHT AGGREGATE ASTM C330
• MIXING WATER ASTM C1602
• ADMIXTURES
• WATER REDUCTION AND SETTING TIME MODIFICATION ASTM C494
• PRODUCING FLOWING CONCRETE ASTM C107
• AIR ENTRAINMENT ASTM C260
• INHIBITING CHLORIDE-INDUCED CORROSION ASTM C1582
5. REINFORCING MATERIALS:
• REINFORCING BARS PLAIN-STEEL ASTM A615, GRADE 60, DEFORMED
• REINFORCING BARS LOW-ALLOY-STEEL ASTM A706, DEFORMED
(WELDABLE)
• REINFORCING BARS EPOXY-COATED ASTM A775
• WELDED WIRE FABRIC ASTM A1064
• EPOXY-COATED WELDED WIRE FABRIC ASTM A884, CLASS A COATING
6. REINFORCING SHALL COMPLY WITH ACI FOR FABRICATING, PLACING, AND
SUPPORTING REINFORCEMENT, AND THE FOLLOWING:
• BAR SPLICE LOCATIONS SHALL CONFORM TO ACI 318
• HORIZONTAL REINFORCING BARS IN WALLS AND FOOTINGS SHALL BE
CONTINUOUS AROUND CORNERS.
• UNLESS DETAILED CALCULATIONS ARE PROVIDED, REINFORCING BARS
DEVELOPMENT LENGTHS, EMBEDMENT DEPTHS AND LAP SPLICE DISTANCES
FOR f'c = 4000psi, NORMAL-WEIGHT CONCRETE, SHALL BE PER BELOW
7. EMBEDDED AND MISCELLANEOUS STEEL SHALL COMPLY WITH ASTM A36.
8. CONTINUOUS WALL OR FOOTING PLACEMENT SHALL NOT EXCEED 60 FEET
BETWEEN CONSTRUCTION JOINTS.
9. ALL EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED 3/4" AT 45 DEGREES
UNLESS NOTED OTHERWISE.
10. SHALLOW INTERIOR FOUNDATIONS AND SLABS ON GRADE ARE NOT DESIGNED FOR
OR INTENDED TO BE EXPOSED TO FREEZE/THAW CYCLING OR RESIST FROST
HEAVE FORCES. GENERAL CONTRACTOR TO COORDINATE CONSTRUCTION AND
PROVIDE INTERIOR FOOTINGS BELOW FROST PENETRATION AS REQUIRED FOR
WINTER CONSTRUCTION.
11. PROVIDE CONSTRUCTION / CONTROL JOINT INSTALLATION PLAN AND PLACEMENT
SEQUENCE PLAN SUBMITTALS FOR REVIEW OF STRUCTURAL ENGINEER OF
RECORD PRIOR TO PLACING CONCRETE.
12. PROVIDE WALL AND SLAB THRU-SLEEVE PLAN SUBMITTALS FOR REVIEW OF
STRUCTURAL ENGINEER OF RECORD PRIOR TO PLACING CONCRETE.
13. CORE-DRILLING CONCRETE WALLS, SLABS, BEAMS OR COLUMNS WITHOUT
REINFORCING LOCATION SCANS AND PRIOR APPROVAL OF STRUCTURAL ENGINEER
OF RECORD SHALL NOT BE PERMITTED.
14. CONDUITS AND PIPES SHALL NOT BE EMBEDDED IN ELEVATED CONCRETE SLABS
SUPPORTED BY METAL DECK OR CONCRETE SLABS ON GRADE.
15. FIBER REINFORCED CONCRETE SHALL COMPLY WITH "GUIDE TO DESIGN WITH
FIBER-REINFORCED CONCRETE" (ACI 544.4), LATEST EDITION. DESIGN
CALCULATIONS SHALL BE SUBMITTED AS PER THE SHOP DRAWING NOTES AND
SPECIFICATIONS.
16. NON-SHRINK GROUT SHALL CONFORM TO ASTM C1107 AND ACHIEVE A MINIMUM 28
DAY COMPRESSIVE STRENGTH OF 8,000 psi.
17. STRUCTURAL ADHESIVES SHALL ONLY BE USED WITH PRIOR PERMISSION OF THE
STRUCTURAL ENGINEER OF RECORD OR AS SHOWN ON CONSTRUCTION
DOCUMENTS. THE BASIS OF DESIGN FOR ADHESIVES IS HY-200 BY "HILTI" OR SET BY
"SIMPSON" - THE USE OF ANY OTHER STRUCTURAL ADHESIVES SHALL BE SUBJECT
TO REVIEW BY THE EOR PRIOR TO INSTALLATION.
18. MINIMUM WIRE WELDED FABRIC REQUIREMENTS FOR SLABS:
• 4" FLOOR SLAB ON GRADE 66-W2.9xW2.9
• 5" FLOOR SLAB ON GRADE 44-W4.0xW4.0
19. COLD-WEATHER CONCRETE PLACEMENT SHALL COMPLY WITH THE PROVISIONS OF
ACI 306R. THE USE OF CALCIUM CHLORIDE, SALT, AND OTHER MATERIALS
CONTAINING ANTI- FREEZE AGENTS OR CHEMICAL ACCELERATORS SHALL NOT
BE PERMITTED UNLESS ACCEPTED IN THE MIX DESIGN.
20. HOT-WEATHER CONCRETE PLACEMENT SHALL COMPLY WITH THE PROVISIONS OF
ACI 305.
21. MINIMUM CONCRETE CLEAR COVER SHALL BE PROVIDED FOR REINFORCEMENT
PER ACI AND THE FOLLOWING:
• CONCRETE CAST AGAINST EARTH & PERMANENTLY 3"
EXPOSED
• CONCRETE EXPOSED TO EARTH OR WEATHER
#6 & LARGER 2"
#5 & SMALLER 1-1/2"
• CONCRETE NOT EXPOSED TO WEATHER OR GROUND
SLABS, WALLS, AND JOINTS 3/4"
BEAMS AND COLUMNS 1-1/2"
BAR LOCATION
VERT. & HORIZ. WALL BARS
FOOTING TOP BARS
FOOTING BOTTOM BARS
BAR SIZE
#3 ld ls ldh
20" 25" 8"
15" 19" 8"
#4 ld ls ldh
25" 33" 10"
19" 25" 10"
#5 ld ls ldh
32" 41" 12"
24" 31" 12"
REBAR LAP SPLICE LENGTHS
20" 25" 8" 25" 33" 10" 32" 41" 12"
VERT. & HORIZ. WALL BARS
FOOTING TOP BARS
FOOTING BOTTOM BARS
#6 ld ls ldh
38" 50" 15"
29" 38" 15"
#7 ld ls ldh
55" 71" 17"
42" 54" 17"
#8 ld ls ldh
62" 81" 19"
47" 62" 19"
38" 50" 15" 55" 71" 17" 62" 81" 19"
NOTE:
• VALUES ABOVE ARE FOR NORMAL WEIGHT CONCRETE ONLY.
• ld = MINIMUM TENSION DEVELOPMENT LENGTH
• ldh = MINIMUM 90 DEGREE HOOKED BAR DEVELOPMENT LENGTH
• ls = MINIMUM LENGTH OF LAP SPLICES IN TENSION
BAR SIZE
CONCRETE MIX DESIGN CRITERIA
FOOTINGS AND
FOUNDATION WALLS
INTERIOR SLABS ON
GRADE
EXPOSURE
CLASS
F1,S0,W0,C1
MAX. w/c
RATIO
0.55
MIN. f'c
3,500
AIR
CONTENT
5%
CEMENT
TYPE
I or II
INTERIOR ELEVATED
SLABS
EXTERIOR SLABS
F0,S0,W0,C1 0.50 4,000 N/A I or II
F0,S0,W0,C1 0.50 4,000 N/A I or II
F3,S0,W0,C2 0.40 5,000 6% I or II
CONCRETE MASONRY
1. ALL MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF
TMS 402/ACI 530/ASCE 5: BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES LATEST EDITION.
2. THE OWNER SHALL ENGAGE A TESTING AND INSPECTION AGENCY TO PERFORM
THE SPECIAL INSPECTIONS REQUIRED BY THE SCHEDULE OF SPECIAL
INSPECTIONS.
3. HOLLOW MASONRY UNITS SHALL BE GRADE N-1 CONFORMING TO ASTM C-90,
UNLESS NOTE OTHERWISE WITH A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI
(MASONRY ASSEMBLY F'm = 2,000 PSI).
4. ALL FILL FOR MASONRY WALLS SHALL BE PEA GRAVEL CONCRETE OR GROUT
CONFORMING TO ASTM C476 WITH A MINIMUM GROUT STRENGTH OF 3,000 PSI AT 28
DAYS. FILL SHALL BE PLACED IN 5'-0" LIFTS IN ACCORDANCE TO INTERNATIONAL
MASONRY INSTITUTE GUIDELINES AND ACI 530.1 / ASCE 6 FOR LOW LIFT GROUTING.
5. ALL MORTAR SHALL BE TYPE "M" CONFORMING TO ASTM C270 WITH A MINIMUM
COMPRESSIVE STRENGTH OF 2,500 PSI AT 28 DAYS.
6. ALL MORTAR FOR MASONRY OTHER THAN VENEER SHALL BE PORTLAND CEMENT
LIME MORTAR, NOT MASONRY CEMENT.
7. VERTICAL WALL REINFORCING SHALL BE INTERMEDIATE GRADE DEFORMED BARS
OF NEW BILLET STEEL CONFORMING TO ASTM A-615, GRADE 60.
8. JOINT REINFORCING SHALL BE 0.148" RODS MIN. CONFORMING TO ASTM A-951.
9. ALL MORTAR JOINTS IN MASONRY WALLS (HORIZONTAL AND VERTICAL) SHALL BE
FULL MORTAR BEDDING.
10. ALL SECTIONS OF BEARING WALLS HAVING A HORIZONTAL PLAN DIMENSION OF 2'-0"
OR LESS SHALL BE OF SOLID (CONCRETE FILLED) MASONRY CONSTRUCTION FOR
THE FULL HEIGHT OF THE WALL SECTION.
11. PROVIDE A MINIMUM OF ONE COURSE OF SOLID BLOCK UNDER ALL JOIST AND SLAB
BEARING ENDS FOR THE FULL WIDTH OF THE WALL, UNLESS NOTED OTHERWISE.
12. BRACE AND SHORE ALL NEW MASONRY WALLS AS REQUIRED UNTIL ROOF AND
FLOOR DECKS HAVE BEEN COMPLETELY INSTALLED.
13. THE TOP OF ALL MASONRY WALLS SHALL BE BRACED TO THE STEEL FRAMING. SEE
TYPICAL DETAILS ON FRAMING SECTIONS AND DETAIL DRAWINGS.
14. BACKFILL AGAINST MASONRY WALLS SHALL BE PLACED AT EQUAL HEIGHTS ON
EACH SIDE OF WALL UP TO FINAL GRADE.
15. QUALITY ASSURANCE PROGRAM TO BE PROVIDED PER SECTION 3.1 OF TMS 402/ACI
16. FILL ALL BLOCK CORES SOLID FROM FOUNDATION TO SLAB ON GRADE.
17. BOND BEAMS WITH HORIZONTAL REINFORCEMENT NOT LESS THAN (2) #5 REBAR
SHALL BE PROVIDED CONTINUOUSLY AT STRUCTURALLY CONNECTED ROOF AND
FLOOR LEVELS, AT THE TOP OF WALLS, AT THE BOTTOM OF WALLS OR IN THE TOP
OF THE FOUNDATION WHEN DOWELING INTO THE WALL.
18. ALL MASONRY WORK TO BE EXECUTED IN HOT OR COLD WEATHER SHALL BE IN
CONFORMANCE WITH THE RECOMMENDATIONS FOR COLD WEATHER
CONSTRUCTION FOUND IN TMS 402/ACI 530 WITH THE FOLLOWING ADDITIONS: FOR
ALL CONDITIONS WHEN TEMPERATURES FALL BELOW 40 DEGREES F, THE
TEMPERATURE OF THE NEWLY LAID MASONRY OR NEWLY GROUTED MASONRY
SHALL BE MAINTAINED ABOVE 30 DEGREES F FOR A MINIMUM OF 24 HOURS USING
THE METHODS DESCRIBED IN TMS 402/ACI 530.
19. UNLESS NOTED OTHERWISE ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE
FOLLOWING MINIMUM REINFORCING SHALL BE USED. ALL CORES WITH
REINFORCING SHALL BE GROUTED SOLID.
MINIMUM WALL REINFORCING
BENEATH STEEL BEAMS
BENEATH STEEL OR CONCRETE LINTELS
REINFORCING
(2) #5 BARS - (1) PER CORE
(1) #5 BAR
LOCATION
INTERIOR NON-LOAD BEARING WALLS
VERTICAL
HORIZONTAL
CORNERS, EA. SIDE OF EA. OPENING, ENDS OF
WALLS, EA. SIDE OF EXPANSION/CRACK
CONTROL JOINTS
TOP OF WALL, BOTTOM AND TOP OF EA.
OPENING
#4 BARS @ 48" o.c.
JOINT REINFORCING @ 16" o.c.
(1) #5 BAR
(1) #5 BAR - EXTEND 24" OR 40
BAR DIAMETERS PAST OPENING
BAR SIZE
LAP SPLICE LENGTH *
#3 #4 #5
REBAR LAP SPLICE LENGTHS
22" 29" 36" 44" 51" 58"
#6 #7 #8
* UNLESS NOTED OTHERWISE
WOOD TRUSSES
1. WOOD TRUSSES ARE TO BE MANUFACTURED IN ACCORDANCE WITH ANSI/TPI 1
"NATIONAL DESIGN STANDARD FOR METAL-PLATE-CONNECTED WOOD TRUSS
CONSTRUCTION", LATEST EDITION.
2. SIGNED AND SEALED SHOP DRAWINGS AND DESIGN CALCULATIONS SHALL BE
SUBMITTED AS PER THE SHOP DRAWING NOTES AND SPECIFICATIONS.
CALCULATIONS SHALL INCLUDE, BUT ARE NOT LIMITED TO:
a. DESCRIPTION OF THE DESIGN CRITERIA
b. ENGINEERING ANALYSIS DEPICTING STRESS AND DEFLECTION
REQUIREMENTS FOR EACH TRUSS APPLICATION
c. SELECTION OF TRUSS COMPONENTS AND ACCESSORIES
d. VERIFICATION OF ATTACHMENT TO STRUCTURE AND/OR ADJACENT
FRAMING COMPONENTS
e. NOTE: TRUSS CONFIGURATIONS SHOWN ON PLANS ARE APPROXIMATE
3. CUTTING, DRILLING, OR NOTCHING ANY OF THE TRUSS MEMBERS IS NOT
PERMITTED WITHOUT APPROVAL FROM THE TRUSS DESIGNER.
4. PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT/BRACING AND THE METHOD
OF ANCHORING OR RESTRAINING TO PREVENT LATERAL MOVEMENT OF ALL TRUSS
MEMBERS SHALL BE ACCOMPLISHED AT MINIMUM BY DETAILS IN ACCORDANCE
WITH BCSI-B3 "PERMANENT RESTRAINT/BRACING OF CHORDS & WEB MEMBERS"
AND/OR BCSI-B7 "TEMPORARY & PERMANENT RESTRAINT/BRACING FOR PARALLEL
CHORD TRUSSES"
5. ANY BRACING REQUIRED IN EXCESS OF BCSI-B3 OR BCSI-B7 SHALL BE PROVIDED BY
THE TRUSS DESIGNER.
6. WOOD TRUSSES SHALL BE CONFIGURED TO ACCOMMODATE MECHANICAL UNIT
LOCATIONS, DUCTWORK RUNS, CATWALKS & STORAGE LOCATIONS. COORDINATE
WITH MECHANICAL & ARCHITECTURAL DRAWINGS.
7. WOOD TRUSSES TO BE DESIGNED FOR CRITERIA IN TABLE BELOW.
WOOD TRUSS DESIGN CRITERIA
TCLL (PSF)
TCDL (PSF)
PRIVATE
ROOMS
PUBLIC
ROOMS
CORRIDOR
SAME AS
AREA SERVED
STORAGE
ROOF
BREAKDOWN
BCLL (PSF) -- -- -- -- --
BCDL (PSF) 5 5 5 5 5
TOTAL (PSF) 65 125 65/125 25 50
LL DEFLECTION (TYP.) L/480 L/480 L/480 L/480 L/480
LL DEFLECTION (@ TILE) L/720 L/720 L/720 L/720 --
TL DEFLECTION (TYP.) L/240 L/240 L/240 L/240 L/240
WALL
THICKNESS
STEEL LINTEL SCHEDULE FOR NON-LOADBEARING
MASONRY WALLS
CLEAR SPAN
4'-0" or Less
L3 1/2x3 1/2x5/16"
(2) L3 1/2x2 1/2x3/8" -or- WT7x11
(2) L3 1/2x3 1/2x5/16" -or- WT7x15
W8x10 w/ 1/4"x0'-9" PL.
(3) L4x3 1/2x3/8" (LLV) -or- W8x10 w/
1/4"x0'-9" PL.
4'-1" to 6'-0"
L4x3 1/2x5/16" (LLV)
(2) L3 1/2x2 1/2x3/8" -or- WT7x11
(2) L3 1/2x3 1/2x5/16" -or- WT7x15
W8x10 w/ 1/4"x0'-9" PL.
(3) L4x3 1/2x3/8" (LLV) -or- W8x10 w/
1/4"x0'-9" PL.
6'-1" to 8'-0"
L5x3 1/2x5/16" (LLV)
(2) L3 1/2x2 1/2x3/8" -or- WT7x11
(2) L5x3 1/2x5/16" (LLV) -or- WT7x15
W8x10 w/ 1/4"x0'-9" PL.
(3) L5x3 1/2"x5/16" (LLV) -or- W8x10 w/
1/4"x0'-11" PL.
8'-1" to 10'-0"
L5x3 1/2x5/16" (LLV)
WT7x11
W8x10 w/ 1/4"x0'-7"
PL.
W8x10 w/ 1/4"x0'-9" PL.
W8x10 w/ 1/4"x0'-11"
PL.
4" CMU
or Brick
6" CMU
8" CMU
10" CMU
12" CMU
NOTES:
1. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL STEEL LINTELS IN ALL MASONRY WALLS, INCLUDING
THE FOLLOWING (REF. CONTRACT DOCUMENTS):
2. ABOVE ALL METAL FRAMES IN MASONRY WALLS.
3. ABOVE ALL NEW OPENINGS, PASSAGES, ROLL-UP OR OVERHEAD DOORS IN MASONRY WALLS.
4. ABOVE ALL NEW DUCTWORK PASSING THROUGH MASONRY WALLS.
5. ABOVE ALL BUILT-IN ITEMS (SUCH AS CABINET HEATERS, CONVECTORS, LOUVERS, ACCESS PANELS, BRICK
GRILLES, WINDOWS, ETC.)
6. AT ALL LOCATIONS WHERE NOTED ON THE PLANS AND/OR WALL SECTIONS. SIZES TO BE AS INDICATED IN THE
SCHEDULE ABOVE. LENGTH TO BE FULL OPENING AND A MINIMUM 8" BEARING ON EACH END.
7. ALL LOOSE LINTELS AT OPENINGS 8" OR LESS FROM STEEL COLUMN SHALL BE ATTACHED W/ CLIP ANGLES TO
COLUMNS. CONTRACTOR SHALL VERIFY ALL CONDITIONS
AND DIMENSIONS FOR THE ENTIRE PROJECT
BEFORE PROCEEDING WITH THE WORK.
DSGN:
JOB:
CHK:
DRAWN: APPRD:
DATE:
SCALE:
P MGR:
COPYRIGHT 2026
SHEET:
F
IL
E N
A M
E
R E
V
IS
IO
N
S D
A T
E
A ut od es k D oc s:
//3
.0
1_ S ug ar lo af
T w p_
L ar oc k_
F ie ld
C o nc e ss io n/
1_ S tr uc t_ S ug ar lo a f- T w p
_L ar o ck
_C o nc es si on
R
.r vt
As indicated
RPK
LW09/21/2026
329526.001
/0
/2
S2.0
RCS
RCS
N ot es a nd S ch ed ul e s N
E W
C O
N C
E S
S
IO
N S
T A
N D
K E
L
LE
R S
R O
A D
, D R
U M
S ,P
A
JO
E
L aR
O C
K R
E C
R E
A T
IO
N
F
IE
LD
LU
Z
E R
N E
C O
U N
T Y
, P A
Is su e d fo r
B id
TK
BENT
BARS (B)
CONT.
BARS
D E
P T
H
WIDTHNOTES:
1. CONTINUOUS BARS SHALL HAVE 3" MINIMUM COVER
ON ALL SIDES.
2. BENT BARS SHALL BE PER THE FOUNDATION WALL
SCHEDULE.
BENT
BARS (B)
NOTES:
1. GROUT ALL CORES SOLID BELOW GRADE w/ 3,000 psi CONCRETE GROUT.
2. REINFORCING SHALL BE CENTERED IN WALL (U.N.O.)
3. PROVIDE HORIZONTAL JOINT REINFORCING PER SPECIFICATIONS -
SPACING NOT TO EXCEED 16" o.c.
4. WALLS WITH MULTIPLE WYTHES SHALL HAVE (1) LAYER OF REINFORCING
PER WYTHE
VERT.
BARS (V)
2'-0" MIN.
SPLICE
WIDTH
JOINT
REINF.
DOWEL
BARS (D)
NOTES:
1. GROUT ALL CORES WITH REINFORCING SOLID w/ 3,000 psi CONCRETE
GROUT.
2. REINFORCING SHALL BE CENTERED IN WALL (U.N.O.)
3. PROVIDE HORIZONTAL JOINT REINFORCING PER SPECIFICATIONS -
SPACING NOT TO EXCEED 16" o.c.
4. DOWEL BAR SIZE AND SPACING SHALL MATCH VERTICAL BARS (U.N.O.)
AND EXTEND 2'-0" INTO WALL BELOW
VERT.
BARS (V)
2'-0" MIN.
SPLICE
WIDTH
JOINT
REINF.
WALL
BELOW
DOWEL
BARS (D)
NOTES:
1. GROUT ALL CORES WITH REINFORCING SOLID w/ 3,000 psi CONCRETE GROUT.
2. REINFORCING SHALL BE CENTERED IN WALL (U.N.O.)
3. PROVIDE HORIZONTAL JOINT REINFORCING PER SPECIFICATIONS - SPACING
NOT TO EXCEED 16" o.c.
4. DOWEL BAR SIZE AND SPACING SHALL MATCH VERTICAL BARS (U.N.O.) AND
EXTEND 2'-0" INTO WALL BELOW
VERT.
BARS (V)
2'-0" MIN.
SPLICE
WIDTH
JOINT
REINF.
WALL
BELOW
NOTES:
1. REINFORCING BARS SHALL HAVE 3" MINIMUM COVER ON ALL SIDES.
2. COLUMNS SHALL BE ATTACHED ACCORDING TO BASE PLATE
SCHEDULE INFORMATION.
3. SEE BASE PLATE DETAILS FOR MORE INFORMATION.
LENGTH
W
ID
T H
T H
IC
K
N E
S S
REINFORCEMENT
1/2" PREMOLDED
FIBER FILLER
#3 TIES @ 1 1/2" o.c.
TOP AND BOTTOM w/
REMAINDER AS
INDICATED IN
SCHEDULE
CONCRETE
SLAB ON
GRADE
SEE FOUNDATION
PLAN FOR PIER
SIZE AND
REINFORCING
SEE FOUNDATION
PLAN FOR
FOOTING SIZE AND
REINFORCING
WRAP MESH
AROUND #4
NOSING BAR
#4 BENT BARS @
16" o.c. AROUND #4
NOSING BAR
SEE FOUNDATION
PLAN FOR FOOTING
SIZE AND
REINFORCING
(2) #5
SEE PLAN
FOR WALL
SIZE AND
REINF.
'-0
(M
IN
8"
SEE PLAN FOR LIMITS
DOOR LOC.
COORD w/
(2) #5
WRAP MESH
AROUND #4
NOSING BAR
EXTERIOR GRADE
COORDINATE w/ SITE
DRAWINGS
'-0
(M
IN
8"
1'-0"
PIPE
6" 6"
SLEEVE
TOP OF
FOOTING
NOTE:
IF DIMENSION TO PIPE SLEEVE IS LESS THAN
THE FOOTING DEPTH, LOWER FOOTING TO
PERMIT PIPE TO PASS THRU WALL ABOVE
FOOTING. REFER TO CONDITION #3 & FOOTING
STEP DOWN DETAILS.
S E
E N
O T
E
T O
P O
F
P
IP
E S
LE
E
V E
6"
UNDERGROUND
PIPE
NOTE:
WHERE TOP OF PIPE / CONDUIT IS BELOW
BOTTOM OF FOOTING BY AT LEAST FOOTING
WIDTH OR 4'-0" WHICHEVER IS GREATER, PIPE
MAY BE RUN UNDER FOOTING WITHOUT A
SLEEVE OR CONCRETE ENCASEMENT .
BOTTOM OF
FOOTING
S E
E N
O T
E
REINFORCED
CONCRETE
FOOTING
PIPE
(SEE MEP
DWGS.)
PIPE SLEEVE
GROUT
M
IN
NOTE:
STEP FOOTING DOWN AS REQUIRED IN
ACCORDANCE WITH TYPICAL WALL FOOTING
STEP DETAIL.
D E
P T
H
F T
G
2'-8" MIN.
CONDUIT
(TYP.)
TOP OF
FOOTING
NOTE:
a. IF DIMENSION TO CONDUIT IS LESS THAN THE FOOTING DEPTH, LOWER FOOTING TO PERMIT CONDUIT TO PASS THRU WALL ABOVE
FOOTING. REFER TO CONDITION #3 & FOOTING STEP DOWN
DETAILS.
b. THE GREATER OF PROVISIONS PER ELECTRICAL
DRAWINGS/SPECIFICATIONS & 3 INCHES.
MIN.
6" b
MIN.
6"
M
IN
S E
E N
O T
E a
T O
P O
F C
O N
D U
IT
b
CONDUIT (TYP.)
NOTE:
STEP FOOTING DOWN AS REQUIRED IN ACCORDANCE
WITH TYPICAL WALL FOOTING STEP DETAIL
REINFORCED
CONCRETE
FOOTING
M
IN
16" DEEP CMU LINTEL
w/ (2) - #5 BARS
MIN
2'-8"
D E
P T
H
F T
G
TOOL OR SAW CUT - 1/4
DEPTH (SAW WITHIN 24 HRS.
OF PLACING CONCRETE)
NOTE: CONTRACTORS OPTION
FOR TYPE OF JOINT
PREMOLDED
KEYED JOINT
STOP REINFORCING 6"
FROM JOINT
SAWED CONTROL JOINT
CONSTRUCTION JOINT
T /3
T
4"
T /3
T
1'-6" 1'-6"
CONTRACTOR SHALL VERIFY ALL CONDITIONS
AND DIMENSIONS FOR THE ENTIRE PROJECT
BEFORE PROCEEDING WITH THE WORK.
CONT. HORIZ TRUSS TYPE
JOINT REINF - 9 GA GALV
METAL @ 16" o.c. VERT.
#5 @ 48" o.c. - GROUT
CORES SOLID @ REINF.
w/ 3000 psi CONC GROUT
BENT BARS -
GROUT CORES
SOLID @ REINF
8" CMU WALL
OR WIDER
P
LA
N
S E
E
P
LA
N
S E
E
PLAN
SEE
NOTES
1. DIMENSIONS SHOWN ARE NOMINAL.
2. PILASTER SHALL EXTEND THE FULL HEIGHT OF THE WALL (U.N.O.)
3. GROUT ALL CORES SOLID w/ 3,000 PSI CONCRETE GROUT.
4. (1) BAR PER CORE (U.N.O.)
5. DBA's SHALL MATCH THE PILASTER AND WALL REINFORCING SIZE
AND EXTEND THE FULL LINTEL LENGTH. DBA SPACING TO BE THE
LESSER OF THE WALL REINFORCING SPACING OR 24".
REINFORCING
LINTEL w/
CONT. PL.
DBA
PLAN
REINFORCING
ELEVATION
LENGTH
W
ID
T H
LENGTH
DSGN:
JOB:
CHK:
DRAWN: APPRD:
DATE:
SCALE:
P MGR:
COPYRIGHT 2026
SHEET:
F
IL
E N
A M
E
R E
V
IS
IO
N
S D
A T
E
A ut od es k D oc s:
//3
.0
1_ S ug ar lo af
T w p_
L ar oc k_
F ie ld
C o nc e ss io n/
1_ S tr uc t_ S ug ar lo a f- T w p
_L ar o ck
_C o nc es si on
R
.r vt
As indicated
RPK
LW09/21/2026
329526.001
/0
/2
S2.1
RCS
RCS
N ot es
S ch ed ul es , a nd D et ai ls N
E W
C O
N C
E S
S
IO
N S
T A
N D
K E
L
LE
R S
R O
A D
, D R
U M
S ,P
A
JO
E
L aR
O C
K R
E C
R E
A T
IO
N
F
IE
LD
LU
Z
E R
N E
C O
U N
T Y
, P A
Is su e d fo r
B id
TK
SCALE: 3/4" = 1'-0"
Typical Pier Detail At Exterior Wall
SCALE: 3/4" = 1'-0"
Typical Exterior Wall At Door Detail
SCALE: 3/4" = 1'-0"
Typical Frost Wall
SCALE: 3/4" = 1'-0"
Typical Pipe at Wall Footing Details
SCALE: 3/4" = 1'-0"
Typical Conduit at Wall Footing Details
SCALE: 3/4" = 1'-0"
Typical Crack Control Joints
SCALE: 3/4" = 1'-0"
Wall Footing Schedule with Masonry Foundation Walls
SCALE: 3/4" = 1'-0"
Column Footing Schedule Detail
SCALE: 3/4" = 1'-0"
Masonry Foundation Wall Schedule
SCALE: 3/4" = 1'-0"
Load Bearing Masonry Wall Schedule
SCALE: 3/4" = 1'-0"
Non-Load Bearing Masonry Wall Schedule
Schedule - Masonry Foundation Wall
MARK WIDTH REINFORCING
MFW12 12" #5 @ 48" o.c. (V) - #5 @ 24" o.c. (B)
Schedule - Masonry Non-Load Bearing Wall
MARK WIDTH REINFORCING
MW8 8" #5 @ 48" o.c. (V)
Schedule - Masonry Load Bearing Wall
MARK WIDTH REINFORCING
MLW8 8" #5 @ 48" o.c. (V)
Schedule - Wall Footing
MARK DEPTH WIDTH REINFORCING
WF1224 1'-0" 2'-0" (3) #5 CONT.
Schedule - Square Column Footing
MARK WIDTH LENGTH THICKNESS REINFORCING
F3.0 3'-0" 3'-0" 1'-0" 3 #5 (E.W.)
SCALE: 3/4" = 1'-0"
Typical Interior Wall Footing
SCALE: 3/4" = 1'-0"
Masonry Pier Schedule
Schedule - Masonry Pilaster
MARK WIDTH LENGTH
VERTICAL
REINFORCING
MP1616 16" 16" (4) #4
CAULK & JOINT
FILLER (B.S.) 3000 PSI CONC GROUT
BUILDING PAPER
(1) #5 (TYP) GROUT
CORES SOLID AT REINF
NOTES:
1. DO NOT EXTEND MASONRY REINF. THROUGH CONTROL JOINTS
2. CONTRACTOR'S OPTION FOR TYPE OF JOINT
SYNTHETIC RUBBER
CONTROL JOINT
MIN
1'-4"
BEARING
SEE PLAN
T.O.M.
SEE PLAN
TOF
SEE PLAN
P A
R A
P E
T
OPEN
OPEN
PROVIDE 1'-4" MIN.
BETWEEN WALL OPENINGS
FOR MECHANICAL
PENETRATIONS
LINTEL
(SEE PLAN)
LINTEL
(SEE PLAN)
WELD DOWELS TO
LINTELS PER LINTEL
SCHEDULES
MASONRY PIERS
MASONRY
PIERS
SEE "MASONRY WALL
REINFORCING
SCHEDULE" OF SIZE &
SPACING OF VERTICAL
REINFORCEMENT
END OF
WALL
BOND BEAM
PROVIDE ONE COURSE
SOLID GROUTED MASONRY
ABOVE ALL LINTELS
CONTROL
JOINT
CONTROL
JOINT
SEE "MASONRY WALL REINFORCING
SCHEDULE" FOR FOOTING DOWEL
REINFORCEMENT
HORIZONTAL BOND BEAM
REINFORCEMENT SHALL
BE CONTINUOUS
THROUGH ALL CONTROL
JOINTS
BARS EACH SIDE OF CONTROL
JOINT PER "TYPICAL MASONRY
WALL CONTROL JOINTS &
HORIZONTAL JOINT
REINFORCEMENT" DETAIL
PROVIDE MINIMUM TWO
COURSES SOLID GROUT BELOW
ALL LINTELS
ADDED BARS AT WINDOW SILL:
(2) #4 FOR OPENINGS LESS THAN OR EQUAL TO 4' - 0"
(2) #5 FOR OPENINGS LESS THAN OR EQUAL TO 6' - 8"
(2) #6 FOR OPENINGS LESS THAN OR EQUAL TO 13' - 0"
EXTEND BARS 48 BAR DIA. BEYOND OPENINGS
CONTINUE HORIZONTAL
REINF. THRU CONTROL JOINT
ONLY AT WINDOW SILL
SEE "MASONRY WALL
REINFORCING SCHEDULE" FOR
DOWEL REINF. INTO BOND BEAM
SEE "TYPICAL MASONRY WALL
CONTROL JOINTS & HORIZONTAL
JOINT REINFORCEMENT" DETAIL
FOR HORIZONTAL JOINT
REQUIREMENTS
GROUT PARAPET
SOLID
HORIZONTAL JOINT
REINFORCEMENT TO
BE DISCONTINUOUS AT
ALL CONTROL JOINTS
WIRE SCREEN OR METAL
LATH TO SUPPORT GROUT
IN CORE ABOVE AS
REQUIRED
CAULK JOINTCONTROL JOINT
(NO MORTAR)
1 1/2" x 1/4" x 32" STRAP ANCHOR w/ 3" RIGHT-
ANGLE BENDS EACH END
(16" o.c. MAXIMUM
VERTICALLY)
EMBED BENT ENDS OF
STRAP ANCHOR IN
CORES OF CMU & FILL w/
GROUT
BEARING OR SHEAR WALLS
FILL SOLID
AT ANCHOR
CAULK JOINTCONTROL JOINT
(NO MORTAR)
JOINT STABILIZING
ANCHOR @ 16" o.c.
MAXIMUM VERTICALLY
INTERSECTING
WALL
TYPICAL
NOTE:
1. VERTICAL & HORIZONTAL REINFORCEMENT NOT SHOWN FOR CLARITY
BEARING AND
SHEAR WALL
#5 BENT BAR
CAULK BOTH SIDES
SYNTHETIC RUBBER
CONTROL JOINT
BOND BEAM w/ (2) #5
BARS DO NOT
EXTEND BARS
THROUGH JOINT
(2) #5 - 5'-0" LG
- 2'-6" LEG -
TYP.
BOND BEAM
REINFORCING
(2) #5
2'-0" MIN. BAR
SPLICE
DIAGONAL WEB
MEMBER BRACING TO
BE INSTALLED ON ANY
WEB MEMBER REQUIRING
CONTINUOUS LATERAL
BRACING - TO BE USED AS
BOTH TEMPORARY AND
PERMANENT BRACING
CONTINUOUS BOTTOM
CHORD BRACING TO BE USED
AS BOTH TEMPORARY AND
PERMANENT BRACING
CONTINUOUS LATERAL WEB
MEMBER BRACING AS
INDICATED BY THE TRUSS
MANUFACTURER OR AT 16'
INTERVALS ALONG THE
LENGTH OF THE TRUSS- TO
BE USED AS BOTH TEMPORARY
AND PERMANENT BRACING
SIMPSON H1
HURRICANE
ANCHOR
TEMPORARY CONTINUOUS
LATERAL TOP CHORD
BRACING
PLYWOOD SHEATHING
TO BE USED AS
PERMANENT TOP
CHORD BRACING
BOTTOM CHORD DIAGONAL
BRACING BETWEEN LATERAL
BRACING MEMBERS - TO
BE USED AS BOTH
TEMPORARY AND
PERMANENT
BRACING
10'-0" M
AXIM
UM
O
R SD PER BCSI REQ
UIREM
ENTS
10'-0" MAXIMUM OR
AS SPECIFIED BY
TRUSS MANUFACTURER
6"
CONTRACTOR SHALL VERIFY ALL CONDITIONS
AND DIMENSIONS FOR THE ENTIRE PROJECT
BEFORE PROCEEDING WITH THE WORK.
SCALE: 3/4" = 1'-0"
Typical Bond Beam Detail At Corner
SCALE: 3/4" = 1'-0"
Control Joints
SCALE: 3/8" = 1'-0"
Extra Reinforcing at CMU Wall Openings
SCALE: 3/4" = 1'-0"
Typical Masonry Wall Intersection Details
SCALE: 3/4" = 1'-0"
Typical Bond Beam At Crack Control Joint
DSGN:
JOB:
CHK:
DRAWN: APPRD:
DATE:
SCALE:
P MGR:
COPYRIGHT 2026
SHEET:
F
IL
E N
A M
E
R E
V
IS
IO
N
S D
A T
E
A ut od es k D oc s:
//3
.0
1_ S ug ar lo af
T w p_
L ar oc k_
F ie ld
C o nc e ss io n/
1_ S tr uc t_ S ug ar lo a f- T w p
_L ar o ck
_C o nc es si on
R
.r vt
As indicated
RPK
LW09/21/2026
329526.001
/0
/2
S2.2
RCS
RCS
N ot es
S ch ed ul es , a nd D et ai ls N
E W
C O
N C
E S
S
IO
N S
T A
N D
K E
L
LE
R S
R O
A D
, D R
U M
S ,P
A
JO
E
L aR
O C
K R
E C
R E
A T
IO
N
F
IE
LD
LU
Z
E R
N E
C O
U N
T Y
, P A
Is su e d fo r
B id
TK
SCALE: 1/2" = 1'-0"
Typical Roof Truss Bracing
GRADE
F.F. ELEV. 100'-0"
T.O.W. ELEV. 110'-11"
S3.0
S3.0
CONCRETE
SLAB ON
GRADE
SEE PLAN FOR
FOUNDATION
WALL SIZE AND
REINFORCING
SEE PLAN FOR
FOOTING SIZE
AND
REINFORCING
SEE PLAN FOR
FOOTING SIZE
AND
REINFORCING
SEE PLAN FOR
FOUNDATION
WALL SIZE AND
REINFORCING
A
F.F. ELEV. 100'-0"
T.O.W. ELEV. 110'-11"
S3.0
S3.0
SEE PLAN FOR
FOUNDATION
WALL SIZE AND
REINFORCING
SEE PLAN FOR
FOOTING SIZE
AND
REINFORCING
SEE PLAN FOR
FOUNDATION
WALL SIZE AND
REINFORCING
SEE PLAN FOR
FOOTING SIZE
AND
REINFORCING
SEE PLAN FOR
FOUNDATION
WALL SIZE AND
REINFORCING
SEE PLAN FOR
FOOTING SIZE
AND
REINFORCING
SEE PLAN FOR
FOOTING SIZE
AND
REINFORCING
SEE PLAN FOR
FOUNDATION
WALL SIZE AND
REINFORCING
SEE PLAN FOR
FOUNDATION
WALL SIZE AND
REINFORCING
SEE PLAN FOR
FOOTING SIZE
AND
REINFORCING
CONCRETE
SLAB ON
GRADE
BOND BEAM w/
(2) #5 CONT.
BARS
BOND BEAM w/
(2) #5 CONT.
BARS
BOND BEAM w/
(2) #5 CONT.
BARS
BOND BEAM w/
(2) #5 CONT.
BARS
BOND BEAM w/
(2) #5 CONT.
BARS
LVL BEAM
BEYOND
COLUMN
BEYOND
SIMPSON
A35F
CONN.
2x4 BLOCKING @ 48" o.c. -
FIRST 2 TRUSS
SPACES
PLYWOOD
SHEATHING
2x4 KICKERS @ 48" o.c. TO
ROOF DECK
ROOF
TRUSSES
SIMPSON
A35F CONN.
CONT. 2x4
BLOCKING
WOOD BLKG.
BETWEEN
TRUSSES
GABLE END
TRUSS - DROP
TOP CHORD FOR
OUTRIGGERS
2x4
OUTRIGGERS
@ 24" o.c.
CMU WALL
PLYWOOD
SHEATHING
ROOF
TRUSS
SIMPSON H1A
HURRICANE TIE
(2) 2x TOP PLATE -
SEE SCHEDULE
DRAWINGS
SEE ARCH
BOND BEAM
w/ (2) #5 BARS SIMPSON TITEN HD
(THD50800H) 1/2" DIA
ANCHOR w/ 4" MIN
GROUT EMBED.
DSGN:
JOB:
CHK:
DRAWN: APPRD:
DATE:
SCALE:
P MGR:
COPYRIGHT 2026
SHEET:
F
IL
E N
A M
E
R E
V
IS
IO
N
S D
A T
E
A ut od es k D oc s:
//3
.0
1_ S ug ar lo af
T w p_
L ar oc k_
F ie ld
C o nc e ss io n/
1_ S tr uc t_ S ug ar lo a f- T w p
_L ar o ck
_C o nc es si on
R
.r vt
As indicated
RPK
LW09/21/2026
329526.001
/0
/2
S3.0
RCS
RCS
S ec tio ns
N E
W C
O N
C E
S S
IO
N
S T
A N
D
K E
L
LE
R S
R O
A D
, D R
U M
S ,P
A
JO
E
L aR
O C
K R
E C
R E
A T
IO
N
F
IE
LD
LU
Z
E R
N E
C O
U N
T Y
, P A
Is su e d fo r
B id
TK
SCALE: 1/4" = 1'-0"S3.0
1 Section
SCALE: 1/4" = 1'-0"S3.0
2 Section
SCALE: 3/4" = 1'-0"S3.0
4 Typical Section At Gable End
SCALE: 3/4" = 1'-0"S3.0
3 Typical Truss Bearing Detail
NOTE:
NOT ALL ABBREVIATIONS AND SYMBOLS INDICATED
MAY APPEAR ON THESE CONTRACT DRAWINGS.
THIS IS FOR REFERENCE ONLY.
ABBREVIATIONS
A/C
AFF
AFG
AMB
AMP
AP
APROX
ARR
ATC
AUTO
AUX
AVG
BF
BHP
BOD
BOP
BOT
BP
BSMT
BTU
CA
CAP
CF
CFM
CL
CO
COL
CONC
CONN
CONT
CTR
D
DB
DDC
DEG
DET
DIA
DISC
DN
DWG
EA
EAT
EER
EFF
EJ
EL
ELEC
ENT
ESP
EVAP
EWT
EXH
EXP
EXST
EXT
F&T
FC
FDW
FLA
FLR
FO
FPM
FPS
FS
FT
GA
GAL
GALV
GND
GPH
GPM
GR
HD
HG
HGT
HMD
HORIZ
HP
HTD
HTR
AIR CONDITIONING
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMBIENT
AMPERE
ACCESS PANEL
APPROXIMATE
ARRANGEMENT
AUTOMATIC TEMPERATURE CONTROL
AUTOMATIC
AUXILIARY
AVERAGE
BOILER FEED
BRAKE HORSEPOWER
BOTTOM OF DUCT
BOTTOM OF PIPE
BOTTOM
BACK PRESSURE
BASEMENT
BRITISH THERMAL UNIT
COMPRESSED AIR
CAPACITY
CUBIC FOOT (FEET)
CUBIC FOOT (FEET) PER MINUTE
CENTER LINE
CLEANOUT
COLUMN
CONCRETE OR CONCENTRIC
CONNECT OR CONNECTION
CONTINUATION
CENTER
DRAIN OR DEEP
DRY BULB
DIRECT DIGITAL CONTROL
DEGREE
DETAIL
DIAMETER
DISCONNECT
DOWN
DRAWING
EACH
ENTERING AIR TEMPERATURE
ENERGY EFFICIENCY RATIO
EFFICIENCY
EXPANSION JOINT
ELEVATION
ELECTRICAL
ENTERING
EXTERNAL STATIC PRESSURE
EVAPORATOR
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
EXISTING
EXTERNAL
FLOAT & THERMOSTATIC
FLEXIBLE CONNECTION
FEED WATER
FULL LOAD AMPS
FLOOR
FUEL OIL
FOOT (FEET) PER MINUTE
FOOT (FEET) PER SECOND
FLOW SWITCH
FOOT (FEET)
GAUGE
GALLONS
GALVANIZED
GROUND
GALLONS PER HOUR
GALLONS PER MINUTE
GRAIN
HEAD
HOT GAS
HEIGHT
HUMIDITY
HORIZONTAL
HORSEPOWER
HEATED
HEATER
Hz
INSUL
INTL
LAT
LBS
LIN
LP
LRA
LVL
LVR
LWT
MAN
MAX
MBH
MIN
MOD
MTD
MU
NA
NC
NEG
NIC
NO
NTS
OA
OED
OFCI
OV
PCR
PD
PG
PL
PNEU
PRESS
PROP
PSIG
QTY
REF
REQD
REV
RL
RM
RS
RTN
S
SCH
SD
SEC
SENS
SEP
SEQ
SER
SERV
SHT
SOL
SP
SPLY
SS
STL
SUCT
TD
TEMP
TH
THK
TSP
TYP.
UON
V
VAC
VAV
VB
VEL
VERT
VIB
VOL
VSD
VTR
W
WB
WMS
HERTZ
INSULATION
INTERNAL
LEAVING AIR TEMPERATURE
POUNDS
LINEAL
LOW PRESSURE
LOCKED ROTOR AMPS
LEVEL
LOUVER
LEAVING WATER TEMPERATURE
MANUAL
MAXIMUM
THOUSAND BRITISH THERMAL UNITS PER HOUR
MINIMUM
MODEL
MOUNTED
MAKEUP
NOT APPLICABLE
NORMALLY CLOSED
NEGATIVE
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OPEN END DUCT
OWNER FURNISHED CONTRACTOR INSTALLED
OUTLET VELOCITY
PUMPED CONDENSATE RETURN
PRESSURE DROP
RESSURE GAUGE
PLATE
PNEUMATIC
PRESSURE
PROPELLER
POUNDS PER SQUARE INCH GAUGE
QUANTITY
REFERENCE
REQUIRED
REVISION
REFRIGERANT LIQUID
ROOM
REFRIGERANT SUCTION
RETURN
SWITCH
SCHEDULE
SMOKE DAMPER
SECONDARY SECONDS
SENSIBLE
SEPARATE
SEQUENCE
SERIES
SERVICE
SHEET
SOLENOID
STATIC PRESSURE
SUPPLY
STAINLESS STEEL
STEEL
SUCTION
TEMPERATURE DIFFERENTIAL
TEMPERATURE
THERMOMETER
THICK
TOTAL STATIC PRESSURE
TYPICAL
UNLESS OTHERWISE NOTED
VENT OR VOLT
VACUUM
VARIABLE AIR VOLUME
VACUUM BREAKER
VELOCITY
VERTICAL
VIBRATION
VOLUME
VARIABLE SPEED DRIVE
VENT THRU ROOF
WATT, WIDTH OR WIDE
WET BULB
WIRE MESH SCREEN
SYMBOL DESCRIPTION
SHUT-OFF VALVE
GLOBE VALVE
CHECK VALVE
FLOW SETTER
ANGLE GATE VALVE
RELIEF OR SAFETY VALVE
SOLENOID VALVE
BUTTERYFLY VALVE
2-WAY CONTROL VALVE
3-WAY CONTROL VALVE
PRESSURE REDUCING VALVE
UNION
STRAINER W/BLOW-OFF & CAP
PIPE GUIDE
PIPE ANCHOR
FLEXIBLE CONNECTOR
EXPANSION JOINT
THERMOMETER
PRESSURE GAUGE W/COCK
AUTOMATIC AIR VENT
MANUAL AIR VENT
DIRECTION OF FLOW
DIRECTION OF SLOPE
CONCENTRIC REDUCER
ECCENTRIC REDUCER
PIPE UP
PIPE DOWN
PIPE THROUGH
TOP TAKE-OFF
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW WORK
BOILER FEED WATER
COMPRESSED AIR
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CONDENSATE DRAIN OR DRAIN
FUEL OIL RETURN
FUEL OIL SUPPLY
FUEL OIL TANK VENT
HOT GAS
HIGH PRESSURE CONDENSATE RETURN
HIGH PRESSURE STEAM SUPPLY
HEATING WATER RETURN
HEATING WATER SUPPLY
LOW PRESSURE CONDENSATE RETURN
LOW PRESSURE STEAM SUPPLY
MEDIUM PRESSURE CONDENSATE RETURN
MEDIUM PRESSURE STEAM SUPPLY
PUMPED CONSENSATE RETURN
REFRIGERANT LIQUID
REFRIGERANT SUCTION
VENT LINE
PIPING SYMBOLS
A
M
36x14Ø
UP DN
24x36
DOUBLE LINE
ROUND DUCT UP
45°ELBOW (NO VANES)
DIRECTION OF FLOW
ROUND DUCT DOWN
36x14Ø
UP DN
24x36
SINGLE LINE
NEW WORK
SUPPLY AIR DOWN
SUPPLY AIR UP
EXISTING TO BE REMOVED
EXISTING TO REMAIN
DESCRIPTION
4-WAY DIFFUSER
EXHAUST OR RETURN GRILLE
FLAT OVAL DUCT SIZE
(FIRST FIGURE-SIDE SHOWN)
DUCT INCLINED RISE OR DROP
IN DIRECTION OF FLOW
90° ELBOW WITH
TURNING VANES
SUPPLY OR RETURN BRANCH CONNECTION
SUPPLY BRANCH WITH SPIN
COLLAR CONNECTION
LATERAL CONNECTION
ROUND DUCTWORK
CONICAL TEE ROUND DUCTWORK
EXHAUST OR RETURN AIR UP
EXHAUST OR RETURN AIR DOWN
DUCTWORK SYMBOLS
3-WAY, 2-WAY, OR 1-WAY GRILLE
RECTANGULAR DUCT SIZE SHOWN IN
INCHES (FIRST FIGURE-SIDE SHOWN)
DUCT SMOKE DETECTOR SDT
MOTORIZED DAMPER
BACK DRAFT DAMPER
VOLUME DAMPER
MD
FLEXIBLE DUCTWORK
(DUCT PRESSURE CLASS)
SMOKE DAMPER WITH ACCESS DOOR
FIRE DAMPER WITH ACCESS DOOR
COMBINATION FIRE & SMOKE
DAMPER WITH ACCESS DOOR
MD
BDD BDD
BYPASS DAMPER
BD BD
STATIC PRESSURE SENSOR
SP SP
POINT OF CONNECTION-NEW TO EXISTING
H HUMIDISTAT
DRAWING NOTE SYMBOL
REVISION SYMBOL
# SECTION NUMBER
# DETAIL OR SECTION NUMBER
DIRECTION OF VIEW
MISCELLANEOUS SYMBOLS
T THERMOSTAT
DRAWING FROM WHICH SECTION
OR DETAIL IS TAKEN
DRAWING ON WHICH SECTION
OR DETAIL IS SHOWN
S SWITCH
POINT OF DEMOLITION CONCLUSION
CWS
V
LPR
LPS
PCR
MPS
RS
RL
MPR
FOR
FOS
HG
FOV
HPR
HPS
HWR
HWS
CD
CHWR
CA
BF
CHWS
CWR
VFD (VARIABLE FREQUENCY DRIVE)
RUNOUT SCHEDULE
FLEXIBLE DUCT
SCHEDULE
0.0 - 3.0
3.1 - 6.5
6.6 - 11.5
11.6 - 18.5
18.6 - 40.0
40.1 - 69.0
69.1 - 122.0
3/4"
1"
1 1/4"
1 1/2"
2"
2-1/2"
3"
GPM PIPE SIZE
CFM
UP TO 125
126 TO 280
281 TO 380
381 TO 550
551 TO 750
DUCT DIAMETER
6"
8"
10"
12"
14"
122.1 - 255.0 4"
255.1 - 750.0 6"
S*
AIR TERMINAL DESIGNATION
AIR TERMINAL NECK SIZE
AIR TERMINAL CFM
DOUBLE-WALL SPIRAL DUCT
(COLOR SHALL BE SELECTED BY ARCHITECT)
MEDIUM PRESSURE DUCTWORK
D
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
ALL WORK AND EQUIPMENT SHALL COMPLY WITH ALL APPLICABLE LAWS, CODES, AND
REQUIREMENTS; OF ALL AUTHORITIES HAVING JURISDICTION, INCLUDING BUT NOT
LIMITED TO THE INTERNATIONAL MECHANICAL CODE, THE INTERNATIONAL PLUMBING
CODE, THE INTERNATIONAL ENERGY CODE, THE LOCAL FIRE MARSHALL, UNDERWRITERS
LABORATORY, IRI, FM, OSHA, AND THE NATIONAL ELECTRICAL CODE. MODIFICATIONS
REQUIRED BY THE ABOVE AUTHORITIES IN ORDER TO BRING THE PROJECT INTO CODE
COMPLIANCE SHALL BE MADE AT NO ADDITIONAL COST TO OWNER. IF CONTRACT
DOCUMENTS ARE MORE STRINGENT THAN CODE REQUIREMENTS, THE CONTRACT
DOCUMENTS SHALL GOVERN.
ALL SPECIFICATIONS AND DRAWINGS ARE COMPLIMENTARY AND MUST BE USED IN
COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. ANY CONFLICTING
INFORMATION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER, AND WORK
SHALL CEASE ON THAT PORTION OF THE PROJECT UNTIL CLARIFICATIONS ARE ISSUED.
HEATING CONTRACTOR (H.C.) AND MECHANICAL CONTRACTOR (M.C.) TERMINOLOGY IS
INTERCHANGEABLE.
CONTRACTOR SHALL CONFIRM THE REQUIREMENTS FOR PREMIUM TIME OR SPECIAL
PROCEDURES WITH THE OWNER. CONTRACTOR SHALL INCLUDE LONG LEAD EQUIPMENT
SUBMITTALS WITH BID PROPOSALS.
CONTRACTOR SHALL COORDINATE, PREPARE AND SUBMIT SHOP DRAWINGS TO THE
ARCHITECT AND ENGINEER FOR APPROVAL. SHOP DRAWINGS TO BE SUBMITTED
INCLUDE: SHEET METAL AND ALL EQUIPMENT. SHEET METAL SHOP DRAWINGS SHALL BE
COORDINATED AND SHOW DUCT ELEVATIONS. INCLUDE RISES, DROPS, AND OFFSETS TO
PROVIDE A COMPLETE AND FUNCTIONAL SYSTEM. AREAS OF POTENTIAL CONFLICT SHALL
BE BROUGHT TO THE ENGINEER'S ATTENTION.
A SET OF MEP RECORD/COORDINATION DRAWINGS SHALL BE MAINTAINED BY THE
CONTRACTOR AT THE JOB SITE. ACTUAL LOCATIONS OF ALL EQUIPMENT, DUCTWORK,
AND ALL OTHER ITEMS INCLUDED IN THIS CONTRACT, AND ALL DEVIATIONS OF THE WORK
FROM THAT SHOWN ON THE CONTRACT DOCUMENTS SHALL BE MARKED ON THE
RECORD/COORDINATION DRAWINGS. EACH TRADE SHALL REVIEW THE COORDINATION
DRAWINGS AND RESOLVE ANY POTENTIAL CONFLICTS WITH OTHER TRADES PRIOR TO
INSTALLING ANY PORTION OF THEIR WORK.
THE MECHANICAL CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER AS-BUILT
DRAWINGS AND OPERATION AND MAINTENANCE MANUALS INCLUDING ALL NAMEPLATE
DATA, WIRING DIAGRAMS, MAINTENANCE INSTRUCTIONS, AND PARTS LIST UPON PROJECT
COMPLETION.
WORK SHALL BE EXECUTED IN A GOOD WORKMANLIKE MANNER USING MECHANICS IN
THEIR RESPECTIVE TRADES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR
COORDINATING THE WORK UNDER THIS CONTRACT. UPON COMPLETION OF
CONSTRUCTION, THE CONTRACTOR SHALL DELIVER COMPLETE AND FUNCTIONAL
SYSTEMS AS ENCOMPASSED BY THE CONTRACT. ALL EQUIPMENT SHALL BE INSTALLED
PER MANUFACTURER'S RECOMMENDATIONS AND CODE REQUIREMENTS.
THE HVAC CONTRACTOR SHALL ARRANGE THE PROGRESS OF HIS WORK SO AS TO
CONFORM TO THE PROGRESS OF THE TRADES AND SHALL COMPLETE THE ENTIRE
INSTALLATION AS SOON AS THE CONDITION OF THE PROJECT WILL PERMIT.
THE CONTRACTOR SHALL PROVIDE ADEQUATE CLEARANCE FOR ALL UNIT CONTROLS.
CONTRACTOR SHALL MAKE ALL FINAL EQUIPMENT CONNECTIONS AND PROVIDE THE
NECESSARY ADAPTERS, FITTINGS, VALVES, AND DEVICES FOR A COMPLETE OPERABLE
SYSTEM. COORDINATE REQUIREMENT FOR PROVISION OF CONTRACTORS AND CONTROL
WIRING FOR PROPER FUNCTIONING SYSTEM WITH ELECTRICAL CONTRACTOR. MOTOR
STARTERS, COMBINATION MOTOR STARTERS, AND DISCONNECTS ARE TO BE PROVIDED
BY THIS CONTRACTOR FOR INSTALLATION BY OTHERS.
FURNISH AND INSTALL ALL EQUIPMENT ELECTRICAL DISCONNECTS UNLESS INDICATED
OTHERWISE. DISCONNECTS SHALL BE PROVIDED BY EQUIPMENT MANUFACTURER AND
SHALL BE IN ACCORDANCE WITH SPECIFICATION SECTION 262816.
CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE RELATION OF PIPING,
DUCTWORK, CONNECTIONS, AND EQUIPMENT. CONTRACTOR SHALL TAKE ALL
INTERFERENCES INTO CONSIDERATION. PROVIDE ALL NECESSARY OFFSETS OR
TRANSITIONS WITH EQUIVALENT AREAS TO MATCH DUCT SIZES AS INDICATED ON
DRAWINGS. ALL PIPING AND DUCTWORK TO BE CONCEALED IN CEILINGS AND WALLS,
EXCEPT IN MECHANICAL ROOMS, SPACES WITHOUT CEILINGS, OR WHERE NOTED
OTHERWISE.
COORDINATE INSTALLATION OF NEW WORK WITH ARCHITECTURAL PLANS, STRUCTURAL
PLANS, AND LIGHTING PLANS. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR CEILING TYPES AND LOCATIONS OF ALL GRILLES AND DIFFUSERS. PROVIDE
APPROPRIATE FRAMES AND MOUNTING HARDWARE FOR ALL AIR DEVICES. MECHANICAL
CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL MOUNTING DETAILS AND
REQUIREMENTS WITH CEILING CONTRACTOR.
COORDINATE EXACT LOCATIONS OF DIFFUSERS/DUCTWORK WITH LIGHTS, SPRINKLERS,
AND CEILING WITH REFLECTED CEILING PLAN AND ARCHITECT.
NO PIPING OR DUCTWORK FOREIGN TO ELECTRICAL, DATA, OR ELEVATOR MACHINE
ROOMS IS PERMITTED TO BE INSTALLED IN THESE SPACES. DO NOT INSTALL ANY
MECHANICAL WORK ABOVE ELECTRICAL PANELS.
ALL DIMENSIONS AND PIPE SIZES ARE IN INCHES UNLESS NOTED OTHERWISE.
INSTALL DUCTWORK IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION
STANDARDS. PRESSURE CLASSIFICATION OF DUCTWORK TO BE AS FOLLOWS:
EXHAUST = 1"
FOR ALL BRANCH DUCT CONNECTIONS TO MAIN TRUNK, PROVIDE 45 DEGREE TRANSITION
FITTING OR CONICAL TAP FOR ROUND DUCT. BUTT FITTINGS ARE NOT PERMITTED.
PROVIDE MANUAL VOLUME DAMPER WITH LOCKING QUADRANT IN ALL BRANCH RUNOUTS.
PROVIDE INDIVIDUAL VOLUME DAMPERS FOR BALANCING ON ALL SUPPLY, RETURN,
RELIEF, AND…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .