2-IFB Dwgs.pdf
PDF 7 MB Posted
- Attached to
- REBID of CD 50 7. 2C Ingram Foster Park
- Solicitation number
- Not on record
- Issued by
- Allegheny County, Pennsylvania
About this file
This document consists of architectural and engineering drawings prepared by Gateway Engineers, Inc. for the Borough of Ingram regarding the renovation of Foster Park restroom facilities. The project involves comprehensive renovation of existing multi-user, accessible restroom facilities including demolition of interior walls and existing plumbing fixtures, replacement of exterior doors, and installation of new ADA-compliant plumbing fixtures and accessories. The scope of work includes replacing water closets, lavatories, and urinals in-kind without reducing the number of existing fixtures; demolishing and reconstructing interior CMU partition walls; installing new toilet partitions, grab bars, mirrors, soap dispensers, paper towel dispensers, and related accessories; relocating electrical junction boxes and switches; and repairing all wall, ceiling, and floor finishes disturbed during construction. The project is designed to comply with the 2021 International Existing Building Code (Level 1 Alterations), 2021 International Building Code, 2021 International Fire Code, and all applicable accessibility standards under ICC A117.1 and the Americans with Disabilities Act. The drawing set includes a cover sheet, general notes and accessibility details, demolition and floor plans, and schedules and details for doors, hardware, and plumbing accessories.
The drawings specify detailed accessibility requirements including precise measurements for clear floor spaces, reach ranges, grab bar installations, water closet positioning, and fixture heights in compliance with ADA standards. All plumbing fixtures are designated as new installations to be selected from manufacturer specifications with options for approved equals, and existing plumbing lines are to be reused for connections per applicable codes and Authority Having Jurisdiction regulations. Door hardware specifications include heavy-duty hollow metal frames with coordinated closers, hinges, kick plates, and push plates; specific hardware sets are detailed in the door schedule. Contractor responsibilities include field verification of all existing dimensions and layouts, protection of existing elements to remain, coordination of all work with manufacturer installation requirements, and immediate notification to the Engineer of Record if structural elements such as concrete lintels do not adequately span modified openings. The document emphasizes that notes and details take precedence over general notes, and contractors are prohibited from scaling drawings to obtain dimensions.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
FU
LL
-S
ER
VI
CE
C
IV
IL
E
NG
IN
EE
RI
NG
F
IR
M
W W
W .G
AT
EW
AY
EN
G
IN
EE
RS
.C O
M
P
IT
TS
BU
RG
H
B
U
TL
ER
, P
1-
5-
4-
PR
EP
AR
ED
F O
R
R
EV
IS
IO
N R
EC
O
R D
N o
D at e
Pa th
F ile na m e=
G :\P ro je ct s\
\6
6\ -0
Fo st er P ar k
AD
A
R es tro om s\ D w g\
-S he et
\A D
A R es tro om R en ov at io n.
dw g Pl ot D at e=
7/
/2
4:
P
M K ay le
M . L an gf or d
Sa ve
D at e= 7/
/2
1:
P M
Project Number:
Drawing Scale:
Date Issued:
Index Number:
Drawn By:
Checked By:
Project Manager:
22.0
G at ew ay E ng in ee rs
In c.
A ll
R ig ht s
R es er ve d
THE GATEWAY ENGINEERS, INC. RETAINS OWNERSHIP RIGHTS OF ALL DATA WITHIN THE PLANS. DATA CONTAINED WITHIN IS ONLY TO BE USED FOR ITS INTENDED PURPOSE BY ITS RESPONSIBLE PARTY. THE USE, REPLICATION, REPRODUCTION, OR REDISTRIBUTION OF DATA CONTAINED WITHIN IS STRICTLY PROHIBITED AND SUBJECT TO LEGAL ACTION. CS
BWF
BWF
AAS/KML
07/17/2026
AS NOTED
C-6106-0008
COVER SHEET
PI
TT
SB
U
R G
H , P
A
C R
AF
TO
N , P
A
W
P R
O
SP
EC
T
AV
EN
U E
FO
ST
ER
A
VE
N
U E
BO
R
O U
G H
O F
IN
G
R
AM
FO
ST
ER
P
AR
K
R
ES
TR
O
O M
R
EN
O R
E-
BI
D
FOSTER PARK RESTROOM RENO RE-BID
PREPARED FOR:
101 FOSTER AVENUE
BOROUGH OF INGRAM
40 W PROSPECT AVENUE
PITTSBURGH, PA 15205
CRAFTON, PA 15205
SITE LOCATION MAP
SITE
NOT TO SCALE
SHEET INDEX
NO. TITLE
CS COVER SHEET
A001 GENERAL NOTES AND ACCESSIBILITY DETAILS
A100 DEMOLITION PLAN AND FLOOR PLANS
A200 SCHEDULES AND DETAILS
PROJECT AND CODE SUMMARY
PROJECT SUMMARY
PROJECT ENTAILS THE RENOVATION OF EXISTING RESTROOM FACILITIES IN AN EXISTING BUILDING. RESTROOMS ARE INTENDED TO BE MULTI USER AND ACCESSIBLE IN NATURE. RENOVATION DOES NOT REDUCE THE NUMBER OF EXISTING PLUMBING FIXTURES.
EXISTING RESTROOM FIXTURES ARE TO BE REPLACED IN-KIND.
APPLICABLE CODES:
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL BUILDING CODE (AS REFERENCED BY THE 2018 IEBC)
2021 INTERNATIONAL FIRE CODE, NFPA AS REFERENCED
2021 INTERNATIONAL ENERGY CONSERVATION CODE (AS REFERENCED BY THE 2018 IEBC)
ALLEGHENY COUNTY PLUMBING CODE
CODE COMPLIANCE PATHWAY: 2021 INTERNATIONAL EXISTING BUILDING CODE, LEVEL 1 ALTERATIONS
BUILDING INFORMATION
TYPE OF CONSTRUCTION: VB
BUILDING HEIGHT AND AREA: EXISTING, NO CHANGE
PROJECT DOES NOT CONSTITUTE A CHANGE OF USE OR OCCUPANCY
2021 INTERNATIONAL EXISTING BUILDING CODE SUMMARY
SECTION 302.3 MATERIALS ALREADY IN USE IN A BUILDING IN COMPLIANCE WITH REQUIREMENTS OR APPROVALS IN EFFECT AT THE TIME OF THEIR ERECTION OR INSTALLATION SHALL BE PERMITTED TO REMAIN IN USE UNLESS DETERMINED BY THE CODE OFFICIAL TO BE UNSAFE.
SECTION 302.4 EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS SHALL BE PERMITTED FOR REPAIRS AND ALTERATIONS, PROVIDED THAT UNSAFE CONDITIONS ARE NOT CREATED. HAZARDOUS MATERIALS SHALL NOT BE USED WHERE THE CODE FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR USE
IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND LOCATION.
SECTION 306.2 BUILDINGS AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE ACCESSIBLE IN ACCORDANCE WITH THIS CODE AND
THE ALTERATION AND EXISTING BUILDING PROVISIONS IN ICC A117.1, AS APPLICABLE.
SECTION 306.3.1 PROHIBITED REDUCTION IN ACCESSIBILITY. AN ALTERATION THAT DECREASES OR HAS THE EFFECT OF DECREASING ACCESSIBILITY OF A BUILDING, FACILITY OR ELEMENT, THEREOF, BELOW THE REQUIREMENTS FOR NEW CONSTRUCTION AT THE TIME OF THE ALTERATION IS PROHIBITED. THE NUMBER OF ACCESSIBLE ELEMENTS NEED NOT EXCEED THAT REQUIRED FOR NEW CONSTRUCTION AT THE
TIME OF ALTERATION.
SECTION 306.4 EXTENT OF APPLICATION. AN ALTERATION OF AN EXISTING FACILITY SHALL NOT IMPOSE A REQUIREMENT FOR GREATER
ACCESSIBILITY THAN THAT WHICH WOULD BE REQUIRED FOR NEW CONSTRUCTION.
SECTION 306.7 A FACILITY THAT IS ALTERED SHALL COMPLY WITH THE APPLICABLE PROVISIONS IN CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE, ICC A117.1 AND THE PROVISIONS OF SECTIONS 306.7.1 THROUGH 306.7.16, UNLESS TECHNICALLY INFEASIBLE. WHERE COMPLIANCE WITH THIS SECTION IS TECHNICALLY INFEASIBLE, THE ALTERATION SHALL PROVIDE ACCESS TO THE MAXIMUM EXTENT TECHNICALLY FEASIBLE.
SECTION 306.7.1 ALTERATIONS AFFECTING AN AREA CONTAINING A PRIMARY FUNCTION. INSIGHTS WHERE AN ALTERATION AFFECTS THE ACCESSIBILITY TO, OR CONTAINS AN AREA OF PRIMARY FUNCTION, THE ROUTE TO THE PRIMARY FUNCTION AREA SHALL BE ACCESSIBLE. THE ACCESSIBLE ROUTE TO THE PRIMARY FUNCTION AREA SHALL INCLUDE TOILET FACILITIES AND DRINKING FOUNTAINS SERVING THE AREA OF PRIMARY FUNCTION.EXCEPTIONS: 1.THE COSTS OF PROVIDING THE ACCESSIBLE ROUTE ARE NOT REQUIRED TO EXCEED 20 PERCENT OF THE COSTS OF THE ALTERATIONS AFFECTING THE AREA OF PRIMARY FUNCTION.4.THIS PROVISION DOES NOT APPLY TO ALTERATIONS UNDERTAKEN
FOR THE PRIMARY PURPOSE OF INCREASING THE ACCESSIBILITY OF A FACILITY.
SECTION 306.7.6 EXTERIOR ACCESSIBLE ROUTES, INCLUDING CURB RAMPS, SHALL BE NOT LESS THAN 36 INCHES MINIMUM IN WIDTH.
SECTION 701.2 AN EXISTING BUILDING OR PORTION THEROF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN ITS
EXISTING CONDITION.
SECTION 702.1 NEWLY INSTALLED INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH CHAPTER 8 OF THE IBC.
SECTION 702.2 NEW INTERIOR FLOOR FINISH, INCLUDING NEW CARPETING USED AS AN INTERIOR FLOOR FINISH MATERIAL, SHALL COMPLY WITH
SECTION 804 OF THE IBC.
SECTION 702.3 NEWLY INSTALLED INTERIOR TRIM MATERIALS SHALL COMPLY WITH SECTION 806 OF THE IBC.
SECTION 703.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE PROTECTION PROVIDED.
SECTION 704.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF PROTECTION PROVIDED FOR THE MEANS OF EGRESS.
SECTION 708.1 LEVEL 1 ALTERATIONS TO EXISTING BUILDINGS OR STRUCTURES DO NOT REQUIRE THE ENTIRE BUILDING OR STRUCTURE TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE IECC. THE ALTERATIONS SHALL CONFORM TO THE ENERGY REQUIREMENTS OF THE IECC AS
THEY RELATE TO NEW CONSTRUCTION ONLY.
SECTION C501.1.1 EXCEPT AS SPECIFIED IN THIS CHAPTER, THIS CODE SHALL NOT BE USED TO REQUIRE THE REMOVAL, ALTERATION OR ABANDONMENT OF, NOR PREVENT THE CONTINUED USE AND MAINTENANCE OF, AN EXISTING BUILDING OR BUILDING SYSTEM LAWFULLY IN
EXISTENCE AT THE TIME OF ADOPTION OF THIS CODE.
SECTION C503.1 ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF SECTION C503. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NOT LESS CONFORMING TO THE PROVISIONS OF THIS CODE THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION. ALTERATIONS TO AN EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF SHALL CONFORM TO THE PROVISIONS OF THIS CODE AS THOSE PROVISIONS RELATE TO NEW CONSTRUCTION WITHOUT REQUIRING THE UNALTERED PORTIONS OF THE EXISTING BUILDING OR BUILDING SYSTEM TO COMPLY WITH THIS CODE. ALTERATIONS SHALL NOT CREATE AN UNSAFE OR HAZARDOUS CONDITION OR OVERLOAD EXISTING BUILDING SYSTEMS. EXCEPTION: 3.EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION, PROVIDED THAT THESE CAVITIES ARE FILLED WITH INSULATION.4.CONSTRUCTION WHERE THE
EXISTING ROOF, WALL OR FLOOR CAVITY IS NOT EXPOSED.
SECTION C504.1 BUILDINGS AND STRUCTURES, AND PARTS THEREOF, SHALL BE REPAIRED IN COMPLIANCE WITH SECTION C501.3 AND THIS SECTION. WORK ON NONDAMAGED COMPONENTS THAT IS NECESSARY FOR THE REQUIRED REPAIR OF DAMAGED COMPONENTS SHALL BE CONSIDERED TO BE PART OF THE REPAIR AND SHALL NOT BE SUBJECT TO THE REQUIREMENTS FOR ALTERATIONS IN THIS CHAPTER. ROUTINE MAINTENANCE REQUIRED BY SECTION C501.3, ORDINARY REPAIRS EXEMPT FROM PERMIT AND ABATEMENT OF WEAR DUE TO NORMAL SERVICE CONDITIONS SHALL NOT BE SUBJECT TO THE REQUIREMENTS FOR REPAIRS IN THIS SECTION.WHERE A BUILDING WAS CONSTRUCTED TO COMPLY WITH ANSI/ASHRAE/IESNA 90.1, REPAIRS SHALL COMPLY WITH THE STANDARD AND NEED NOT COMPLY WITH SECTIONS C402-C405.
ADDL - ADDITIONAL
ALT - ALTERNATE
ARCH - ARCHITECTURAL
BLDG - BUILDING
BLK (G) - BLOCK(ING)
BTM/ xxx - BOTTOM OF xxx
BTM - BOTTOM
BS - BOTH SIDES
BTW - BETWEEN
CL - CENTERLINE
CLR - CLEAR(ANCE)
CMU - CONCRETE MASONRY UNIT
COL - COLUMN
CONC - CONCRETE
CONN - CONNECTION
CONST - CONSTRUCTION
CONT - CONTINUOUS
CONTR - CONTRACTOR
COORD - COORDINATE
CTR - CENTER(ED)
D - DEPTH or DEEP
DBL - DOUBLE
DEG - DEGREE
DEM - DEMOLITION
DET - DETAIL
DIA - DIAMETER
DIAG - DIAGONAL
DIM - DIMENSION
DIST - DISTANCE
DN - DOWN
DWG - DRAWING
EA - EACH
ELEC - ELECTRICAL
EQ - EQUAL
EW - EACH WAY
EXIST - EXISTING
EXT - EXTERIOR
FIN - FINISH(ED)
FLR - FLOOR
FO xxx - FACE OF xxx
FOF - FACE OF FINISH
FT - FOOT or FEET
GEN - GENERAL
GWB - GYPSUM WALLBOARD
HORIZ - HORIZONTAL
HT - HEIGHT
HVAC - HEATING, VENTILATING/
AIR CONDITIONING
IN - INCHES
INFO - INFORMATION
INSUL - INSULATE or INSULATION
JT - JOINT
L - LENGTH
MAS - MASONRY
MAX - MAXIMUM
MECH - MECHANICAL
MFR - MANUFACTURE(R/D)
MIN - MINIMUM
MISC - MISCELLANEOUS
NA - NOT APPLICABLE
NIC - NOT IN CONTRACT
NIP - NOT IN PERMIT
A. - NUMBER
NTS - NOT TO SCALE
OC - ON CENTER
OFCI - OWNER FURNISHED
CONTRACTOR INSTALLED
OFI - OWNER FURNISHED AND
INSTALLED
PLWD - PLYWOOD
PSF - POUNDS PER SQUARE FOOT
PSI - POUNDS PER SQUARE INCH
PT - POINT
REF - REFERENCE
REQD - REQUIRED
SHTG - SHEATHING
SIM - SIMILAR
SPEC - SPECIFICATION
STD - STANDARD
TBR - TO BE REMOVED
THK - THICK(NESS)
TO xxx - TOP OF xxx
TOC - TOP OF CONCRETE
TOSL - TOP OF SLAB
TYP - TYPICAL
UNO - UNLESS NOTED OTHERWISE
VERT - VERTICAL
W - WIDTH
W/ - WITH
W/O - WITHOUT
ABBREVIATIONS
48 min m in m in
18 min
(a) front approach, pull side m in
12 min
(c) front approach, push side, door provided with both closer and latch
(i) latch approach, pull side, door provided with closer m in
70 610 24 min
(k) latch approach, push side, door provided with closer
24 min 12 m in
(a) hinged door
32 min m in
24 min m in
36 min
12 min
12 min
60 min base ar m ar m
30 min
48 min m in m in
(a) forward
(b) parallel
4 max
X ³
X m in
48 min 24 max m in m in m in
24 max
17-25
430-635 6 max m in
(a) elevation
(b) plan m in m ax
16-18 405-455
LC
(a) wheelchair accessible water closets m ax m ax
>20-25 max 510-635
20 max
(a) (b) m in
42 max
24 min
1-1/2" min transfer side
12 min
LC
24 min
36 min
12 max
42 min
54 min
LC
39-41 990-1040
-4
0-
18 min
Section 609.4
-3
0-
11 min m in
8 min
9 min
(a) elevation
(b) plan m in
25 max
10 max m ax m ax m ax m ax
> 10-24 max 255-610
(a) (b) m in
60 min
(a) adult wall hung water closet
(b) adult floor mounted water closet and children's water closet
60 min m in
17 - 19 430 - 485
Seat height m in
7-9 180-230 m ax
LC
RESTROOM
9" ON CENTER FROM
DOOR FRAME
RESTROOM
" M
IN
. T
O B
AS
EL
IN
E
O F
BR
AI
LL
E
" M
AX
. T
O B
AS
EL
IN
E
O F
H
IG
H
ES
T
TA
C
TI
LE
C
H
AR
AC
TE
R
RESTROOM
9" ON CENTER FROM
DOOR FRAME
RESTROOM
" M
IN
. T
O B
AS
EL
IN
E
O F
BR
AI
LL
E
" M
AX
. T
O B
AS
EL
IN
E
O F
H
IG
H
ES
T
TA
C
TI
LE
C
H
AR
AC
TE
R
(g) hinge approach, push side, door provided with both closer and latch m in
54 min
(b) stall type
(a) wall hung type
17 max
13½ min 13½ min
A
FU
LL
-S
ER
VI
CE
C
IV
IL
E
NG
IN
EE
RI
NG
F
IR
M
W W
W .G
AT
EW
AY
EN
G
IN
EE
RS
.C
TS
BU
RG
H
B
U
TL
ER
5-
4-
PR
EP
AR
ED
F O
R
R
EV
IS
IO
N R
EC
O
R D
N o
D at e
Pa th
F ile na m e=
G :\P ro je ct s\
\6
6\ -0
Fo st er P ar k
AD
A
R es tro om s\ D w g\
-S he et
\A D
A R es tro om R en ov at io n.
dw g Pl ot D at e=
7/
/2
4:
P
M K ay le
M . L an gf or d
Sa ve
D at e= 7/
/2
1:
P M
Project Number:
Drawing Scale:
Date Issued:
Index Number:
Drawn By:
Checked By:
Project Manager:
22.0
G at ew ay E ng in ee rs
In c.
A ll
R ig ht s
R es er ve d
THE GATEWAY ENGINEERS, INC. RETAINS OWNERSHIP RIGHTS OF ALL DATA WITHIN THE PLANS. DATA CONTAINED WITHIN IS ONLY TO BE USED FOR ITS INTENDED PURPOSE BY ITS RESPONSIBLE PARTY. THE USE, REPLICATION, REPRODUCTION, OR REDISTRIBUTION OF DATA CONTAINED WITHIN IS STRICTLY PROHIBITED AND SUBJECT TO LEGAL ACTION. A001
BWF
BWF
AAS/KML
07/17/2026
AS NOTED
C-6106-0008
GENERAL NOTES
AND ACCESSIBILITY
DETAILS
PI
TT
SB
U
R G
H , P
A
C R
AF
TO
N , P
A
W
P R
O
SP
EC
T
AV
EN
U E
FO
ST
ER
A
VE
N
U E
BO
R
O U
G H
O F
IN
G
R
AM
FO
ST
ER
P
AR
K
R
ES
TR
O
O M
R
EN
O R
E-
BI
D
1. OBTAIN EXTINGUISHERS FROM ONE SOURCE FROM A SINGLE MANUFACTURER. UL-LISTED PRODUCTS: FIRE EXTINGUISHERS SHALL BE UL LISTED WITH UL LISTING MARK FOR TYPE, RATING, AND CLASSIFICATION OF EXTINGUISHER. FIRE EXTINGUISHERS APPROVED BY FACTORY MUTUAL RESEARCH CORPORATION FOR TYPE, RATING, AND CLASSIFICATION OF EXTINGUISHER WITH FM MARKING. FABRICATE AND LABEL FIRE EXTINGUISHERS TO COMPLY WITH NFPA 10, "STANDARDS
FOR PORTABLE FIRE EXTINGUISHERS".
2. PROVIDE FIRE EXTINGUISHERS FOR EACH CABINET AND OTHER LOCATIONS INDICATED, IN COLORS AND FINISHES SELECTED BY ENGINEER FROM MANUFACTURER'S STANDARD THAT COMPLY WITH AUTHORITIES HAVING JURISDICTION.
MULTIPURPOSE DRY CHEMICAL TYPE: UL-RATED 2-A:10:B:C, 5-LB NOMINAL CAPACITY, IN ENAMELED STEEL CONTAINER.
3. INSTALL FIRE EXTINGUISHERS AND CABINETS AS INDICATED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN
INSTRUCTIONS AND RECOMMENDATIONS. COMPLY WITH THE FOLLOWING:
A. MAXIMUM DISTANCE A.F.F. TO TOP OF ANY EXTINGUISHER SHALL BE 4'-0", IN ACCORDANCE WITH THE AMERICANS WITH
DISABILITIES ACT.
5. INSTALL IN LOCATIONS INDICATED OR, IF NOT INDICATED, AT LOCATIONS DIRECTED BY ENGINEER TO COMPLY WITH
APPLICABLE REGULATIONS OF GOVERNING AUTHORITIES.
A. PREPARE RECESSES IN WALLS FOR CABINETS AS REQUIRED BY TYPE AND SIZE OF CABINET AND STYLE OF TRIM AND TO
COMPLY WITH MANUFACTURER'S INSTRUCTIONS.
B. FASTEN MOUNTING BRACKETS AND CABINETS TO STRUCTURE, SQUARE AND PLUMB.
FIRE EXTINGUISHERS 1. SUBMIT SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, AND LARGE-SCALE SECTIONS OF TYPICAL MEMBERS AND OTHER COMPONENTS. SHOW MOUNTING METHODS, GROUNDS, MOUNTING HEIGHTS, LAYOUT, SPACING, REINFORCEMENT, ACCESSORIES, AND INSTALLATION DETAILS.
A. PROVIDE MESSAGE LIST FOR EACH SIGN, INCLUDING LARGE-SCALE DETAILS OF WORDING, LETTERING AND BRAILLE
LAYOUT.
2. FIELD MEASUREMENTS: WHERE SIZES OF SIGNS ARE DETERMINED BY DIMENSIONS OF SURFACES ON WHICH THEY ARE
INSTALLED, VERIFY DIMENSIONS BY FIELD MEASUREMENT BEFORE FABRICATION AND INDICATE MEASUREMENTS ON SHOP
DRAWINGS.
3. THE ENGINEER WILL MAKE THE FINAL SELECTION OF MATERIALS. ALL SIGNAGE SHALL BE FABRICATED AND INSTALLED IN
ACCORDANCE WITH IBC AND ADA REQUIREMENTS.
4. GENERAL: LOCATE SIGNS AND ACCESSORIES WHERE INDICATED, USING MOUNTING METHODS OF TYPES DESCRIBED AND IN
COMPLIANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
A. INSTALL SIGNS LEVEL, PLUMB, AND AT HEIGHTS INDICATED, WITH SIGN SURFACES FREE FROM DISTORTION AND OTHER
DEFECTS IN APPEARANCE.
B. INTERIOR WALL SIGNS: INSTALL SIGNS ON WALLS ADJACENT TO LATCH SIDE OF DOOR WHERE APPLICABLE. WHERE NOT
INDICATED OR POSSIBLE, SUCH AS DOUBLE DOORS, INSTALL SIGNS ON NEAREST ADJACENT WALLS. LOCATE TO ALLOW APPROACH WITHIN 3 INCHES (75 MM) OF SIGN WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN
SWING OF DOOR.
5. PROVIDE BRACKET-MOUNTED UNITS: PROVIDE MANUFACTURER'S STANDARD BRACKETS, FITTINGS, AND HARDWARE AS APPROPRIATE FOR MOUNTING SIGNS THAT PROJECT AT RIGHT ANGLES FROM WALLS AND CEILINGS. ATTACH BRACKETS AND FITTINGS SECURELY TO WALLS AND CEILINGS WITH CONCEALED FASTENERS AND ANCHORING DEVICES TO COMPLY
WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
SIGNAGE NOTES
1. ALL CONSTRUCTION MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND REGULATIONS OF THE INTERNATIONAL BUILDING CODE, 2021 EDITION, AND
ALL OTHER APPLICABLE BUILDING CODES.
2. SPECIFICATIONS, CODES, AND STANDARDS NOTED IN THE CONTRACT DOCUMENTS SHALL BE OF THE LATEST APPROVED ISSUE, INCLUDING SUPPLEMENTS, UNLESS OTHERWISE NOTED. MATERIAL SPECIFICATIONS ARE ASTM LATEST EDITION.
3. THESE DRAWINGS HAVE BEEN PRODUCED ON THE GATEWAY ENGINEERS, INC. CADD SYSTEM. ANY OTHER MARKS AFFIXED TO THE DRAWINGS, OTHER THAN PROFESSIONAL STAMPS AND SIGNATURES, HAVE BEEN MADE WITHOUT THE THE
AUTHORIZATION OF GATEWAY ENGINEERS AND ARE THEREFORE INVALID.
4. IF ANY ERRORS OR OMISSIONS APPEAR IN THESE DRAWINGS, SPECIFICATIONS, OR OTHER DOCUMENTS; THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OR ARCHITECT IN WRITING OF SUCH OMISSION OR ERROR BEFORE PROCEEDING
WITH THE WORK.
5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. THE OWNER AND ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES. THE STRUCTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL STRUCTURAL FEATURES, U.N.O. THE ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK RELATED TO DIMENSIONS.
SCALING OF DRAWINGS TO OBTAIN DIMENSIONS SHALL NOT BE DONE AT ANY TIME. IF A REQUIRED DIMENSION IS NOT PROVIDED, THE CONTRACTOR SHALL SUBMIT A REQUEST FOR INFORMATION TO THE ENGINEER FOR CLARIFICATION. U.N.O.
CONTRACTOR SHALL PROVIDE EQUAL SPACING OF STRUCTURAL COMPONENTS BETWEEN OVERALL DIMENSIONS PROVIDED
ON THE DRAWINGS.
6. NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NOTES AND DETAILS ON DRAWINGS AND THESE GENERAL NOTES AND TYPICAL DETAILS ARE IN CONFLICT WITH THE PROJECT SPECIFICATIONS, CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED AS SHOWN FOR SIMILAR WORK, SUBJECT TO REVIEW BY THE ARCHITECT AND STRUCTURAL ENGINEER.
7. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE; THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE
INSPECTION OF THE ABOVE ITEMS.
8. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE EXISTING AND NEW STRUCTURE AND ALL STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE STRUCTURAL
DOCUMENTS.
9. MANUFACTURED MATERIALS SHALL BE APPROVED BY THE CHECKING AGENCY PRIOR TO THEIR USE. ALL REQUIREMENTS OF
THOSE APPROVALS SHALL BE FOLLOWED.
10. CONTRACTOR SHALL SUBMIT ELECTRONIC COPIES (OF SHOP DRAWINGS, IN PDF FORM, FOR REVIEW OF GATEWAY ENGINEERS, INC. SHOP DRAWINGS SHOULD PROVIDE A COMPLETE COMPLETE INFORMATION FOR THE PRODUCTS AND/OR COMPONENTS BEING SUBMITTED. INCLUDING BUT NOT LIMITED TO: MEMBER SIZES AND LOCATIONS, GRADES OF MATERIALS, MATERIAL FINISH/COATING, CONNECTIONS, AND ANY SPECIAL REQUIREMENTS FOR INSTALLATION/ERECTION.
11. THE CONTRACTOR SHALL NOT DIRECTLY INCORPORATE THE STRUCTURAL DRAWINGS OR ANY PORTIONS THEREOF INTO THE
SHOP DRAWINGS WITHOUT WRITTEN PERMISSION OF GATEWAY ENGINEERS, INC.
12. THE REVIEW OF SHOP DRAWINGS AND OTHER SUBMITTALS FOR THIS PROJECT IS FOR GENERAL CONFORMANCE WITH THE CONTRACT DOCUMENTS. ANY COMMENTS EXPRESSED AS PART OF THE REVIEW OF SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR OF THEIR CONTRACTUAL OBLIGATION TO PROVIDE THE OWNER WITH THE PROJECT OUTLINED IN THE CONTRACT DOCUMENTS. ANY SUBMITTALS REVISED AND RESUBMITTED FOR REVIEW OR RECORD PURPOSES SHALL HAVE
THE SUBSEQUENT REVISIONS CLOUDED ON THE RESUBMITTED SHEETS.
13. ENGINEER IS NOT RESPONSIBLE FOR VERIFICATION OF PRESENCE OF EXISTING FIRE WALLS, FIRE PARTITIONS, SMOKE BARRIERS, ETC. GENERAL CONTRACTOR IS TO NOTIFY ENGINEER IMMEDIATELY IF A RATED ASSEMBLY OR OTHER FIRE PROTECTED ASSEMBLY IS DISTURBED DURING DEMOLITION OR THE COURSE OF NEW CONSTRUCTION.
GENERAL NOTES
603.6 Operable Parts
Operable parts on towel dispensers and hand dryers serviing lavatories complying with Section 606 shall comply with Table 603.6
ICC A117.1 2009 CODE NOTE:
TABLE 603.6 MAXIMUM REACH DEPTH AND HEIGHT
Maximum Reach Depth
Maximum Reach Height
0.5 inch (13 mm)
48 inches (1220 mm)
2 inches (51 mm)
46 inches (1170 mm)
5 inches (125 mm)
42 inches (1065 mm)
6 inches (150 mm)
40 inches (1015 mm)
9 inches (230 mm)
36 inches (915 mm)
11 inches (280 mm)
34 inches (865 mm)
NOTE: SIGNAGE TO BE
PROVIDED BY OWNER
MASONRY NOTES
1. ALL MASONRY WORK SHALL BE IN CONFORMANCE WITH THE LATEST EDITION OF 'BUILDING CODE REQUIREMENTS FOR
MASONRY STRUCTURES', TMS 402/ACI 530/ASCE 5, AND THE 'SPECIFICATIONS FOR MASONRY STRUCTURES', TMS 602/ACI
530/ASCE 6.
2. SOLID AND HOLLOW LOAD BEARING CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. FURNISH CONCRETE BLOCK UNITS WITH NET AREA COMPRESSIVE STRENGTH AS SPECIFIED IN THE ABOVE MENTIONED CODE REFERENCES PER THE UNIT
STRENGTH METHOD.
3. MORTAR SHALL CONFORM TO THE PROPERTY SPECIFICATION OF ASTM 270, TYPE S.
4. GROUT SHALL CONFORM TO ASTM C476. FURNISH FINE GROUT WHEN WIDTH OF GROUT SPACE IS LESS THAN 2" OR WHEN REINFORCING HAS LESS THAN 1/2" CLEARANCE. FURNISH COURSE GROUT AT ALL OTHER INSTANCES.
5. MINIMUM 28 DAY COMPRESSIVE STRENGTH OF MASONRY (F'm) EQUALS 1500 PSI
6. FULL BED AND HEAD JOINTS SHALL BE USED
7. GROUT SOLID ALL CELLS IN MASONRY UNITS CONTAINING REINFORCING, WHERE INSTALLED BELOW GRADE, AND WHERE
INDICATED ON PLANS/SECTIONS.
8. HORIZONTAL JOINT REINFORCING FOR ALL EXTERIOR AND LOAD BEARING WALLS SHALL BE GALVANIZED TRUSS OR LADDER
REINFORCING.
9. ALL MASONRY WORK TO BE COMPLETED IN COLD WEATHER SHALL BE IN CONFORMANCE WITH THE ABOVE MENTIONED CODE
RECOMMENDATIONS FOR COLD WEATHER CONSTRUCTION.
10. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60.
11. PROVIDE LAP SPLICES OF 72 BAR DIAMETERS WHERE SPLICING IS REQUIRED.
AutoCAD SHX Text Figure 305.3 Clear Floor or Ground Space
AutoCAD SHX Text Figure 304.3.2 T-Shaped Turning Space
AutoCAD SHX Text Figure 307.2 Limits of Protruding Objects
AutoCAD SHX Text Figure 403.5.1 Clear Width of an Accessible Route
AutoCAD SHX Text Figure 306.2 Toe Clearance
AutoCAD SHX Text Figure 308.2.1 Unobstructed Forward Reach
AutoCAD SHX Text Figure 604.2 Water Closet location
AutoCAD SHX Text Figure 308.2.2 Obstructed High Forward Reach
AutoCAD SHX Text Figure 604.7 Dispenser Outlet Location
AutoCAD SHX Text Figure 604.5.1 Side Wall Grab Bar at Water Closets
AutoCAD SHX Text Figure 604.5.2 Rear Wall Grab Bar at Water Closets
AutoCAD SHX Text Figure 306.3 Knee Clearance
AutoCAD SHX Text Figure 308.3.2 Obstructed High Side Reach
AutoCAD SHX Text Figure 604.4 Water Closet Seat Height
AutoCAD SHX Text Figure 604.7 Dispenser Outlet Location
AutoCAD SHX Text Figure 605.2 Height and Depth of Urinals
MATERIALPRODUCTTRADENAMEMODELNUMBER
9'-5" F.V.
'-7
4"
F .V
'-9
1 4" F
.V
9'-4" F.V.
REMOVE
EXISTING
FLOOR DRAIN
GRATE,
TYP. OF 2
EXISTING LOUVER
TO REMAIN
REMOVE AND DISPOSE OF
EXISTING WATER CLOSET.
PLUMBING CONNECTIONS ARE
EXISTING TO REMAIN;
PLUMBER SHALL USE EXISTING
LINES TO CONNECT TO NEW
WATER CLOSET FIXTURES PER
APPLICABLE CODES AND AHJ
REGULATIONS, TYP. OF 3
EXISTING PLUMBING
VENT STACK AND
WATERLINE TO
REMAIN
DEMOLISH DOOR AND FRAME;
PATCH AND REPAIR ADJACENT
SURFACES FOR NEW DOOR AND
FRAME INSTALLATION
DEMOLISH EXISTING CMU
PARTITION WALL, TYP.
FLOORS AND WALLS TO BE PATCHED AND
REPAIRED, TYP. ALL SURFACES TO BE PREPARED
FOR NEW CONSTRUCTION. COORDINATE ALL
CONSTRUCTION DOCUMENTS FOR
MANUFACTURER STANDARD PREPARATION AND
INSTALLATION REQUIREMENTS, TYP.
EXISTING CMU
WALL TO REMAIN;
PROTECT
SAW CUT CMU WALL TO SHIFT
DOORWAY; CONTRACTOR SHALL
SHORE OPENING DURING
CONSTRUCTION AND CONFIRM
CONCRETE LINTEL (ABOVE) SPANS
TO RETURN WALL. CONTRACTOR
SHALL INFORM E.O.R. IMMEDIATELY IF
CONCRETE LINTEL DOES NOT SPAN
TO RETURN WALL.
PATCH AND REPAIR SURFACES FOR
NEW DOOR AND FRAME
INSTALLATION.
REMOVE AND DISPOSE OF
EXISTING URINAL. PLUMBING
CONNECTIONS ARE EXISTING
TO REMAIN; PLUMBER SHALL
USE EXISTING LINES TO
CONNECT TO NEW URINAL
FIXTURES PER APPLICABLE
CODES AND AHJ REGULATIONS
REMOVE AND DISPOSE OF
EXISTING LAVATORY. PLUMBING
CONNECTIONS ARE EXISTING TO
REMAIN; PLUMBER SHALL USE
EXISTING LINES TO CONNECT TO
NEW LAVATORY FIXTURES PER
APPLICABLE CODES AND AHJ
REGULATIONS, TYP. OF 2.
EXISTING LOUVER TO REMAIN
EXISTING PLUMBING VENT STACK
AND WATERLINE TO REMAIN
DEMOLISH DOOR AND FRAME;
PATCH AND REPAIR ADJACENT
SURFACES FOR NEW DOOR AND
FRAME INSTALLATION
EXISTING SURFACE-MOUNTED
JUNCTION BOX AND LIGHT SWITCH
TO BE RELOCATED
EXISTING LIGHTING TO
REMAIN; PROTECT.
TYPICAL EACH RESTROOM.
MATERIAL PRODUCT TRADENAME MODELNUMBER
9'-5" F.V.
9'-4" F.V.
4' -6
" H O
LD
C
LE
AR
7"
4'-6" 4'-6"
4' -8
" H O
LD
C
LE
AR
5' -0
5'-0" HOLD
CLEAR 4'-4"
5' -0
" H O
LD
C
LE
AR
5'-0" HOLD
CLEAR
NEW WATER CLOSET PER PLUMBING
FIXTURE SPECIFICATIONS (OR
APPROVED EQUAL). PLUMBER SHALL
USE EXISTING LINES TO CONNECT TO
NEW TOILET PER APPLICABLE CODES
AND AHJ REGULATIONS, TYP. OF 3
D-1
D-2
6" CMU
PARTITION WALL
(6'-6" TALL MIN.),
TYP.
6" CMU
PARTITION WALL
(6'-6" TALL MIN.),
TYP.
CONTRACTOR SHALL REPAIR
ANY WALL, CEILING AND
FLOOR FINISHES DISTURBED
DURING CONSTRUCTION, TYP.
FLOORS AND WALLS TO BE PATCHED AND
REPAIRED, TYP. ALL SURFACES TO BE PREPARED
FOR NEW CONSTRUCTION. COORDINATE ALL
CONSTRUCTION DOCUMENTS FOR
MANUFACTURER STANDARD PREPARATION AND
INSTALLATION REQUIREMENTS, TYP
NEW
STAINLESS
STEEL FLOOR
DRAIN GRATE,
TYP. OF 2
NEW LAVATORY PER PLUMBING
FIXTURE SPECIFICATIONS
(OR APPROVED EQUAL).
USE EXISTING LINES TO CONNECT
TO NEW LAVATORY PER
APPLICABLE CODES AND AHJ
REGULATIONS, TYP. OF 2
NEW URINAL PER PLUMBING
FIXTURE SPECIFICATIONS (OR
APPROVED EQUAL)
USE EXISTING LINES TO CONNECT
TO NEW URINAL PER APPLICABLE
CODES AND AHJ REGULATIONS
NEW TOILET PARTITIONS PER
ACCESSORY SCHEDULE AND
SPECIFICATIONS, TYP.
NEW CMU INFILL TO MATCH
EXISTING WALL THICKNESS. GROUT
CELLS SOLID AND REINF. W/ #5
VERT. BAR. DOWEL INTO BOND
BEAM (ABOVE) AND SLAB-ON-GRADE
(BELOW) WITH #5 DOWELS USING
HILTI-HY 200-R V3 ADHESIVE
ANCHORING SYSTEM (6" MIN.
EMBED) (OR APPROVED EQUAL).
RELOCATE EXISTING
SURFACE-MOUNTED JUNCTION BOX
AND LIGHT SWITCH PER
APPLICABLE ELECTRICAL AND
ACCESSIBILITY CODES
CONTRACTOR SHALL PROTECT VENT
STACK AND WATERLINE DURING
CONSTRUCTION. CONTRACTOR
SHALL CONSTRUCT WALL AROUND
PIPES AS TO NOT DISTURB PIPING. IF
PIPING IS DAMAGED DURING
CONSTRUCTION, CONTRACTOR
SHALL REPAIR AT NO ADDITIONAL
COST. (TYP. OF 2 LOCATIONS)
EXISTING SIDEWALK (TO PARKING)
1'-4" MIN.
1'-6" MAX.
1'-4" MIN.
1'-6" MAX.
SEALING OF EXISTING
CONCRETE, CAULKING
OF FLOOR AND WALL
PERIMETER, ALL
INTERIOR WALL AND
CEILING PAINTING,
INCLUDING EXISTING
LOUVERS, BY OTHERS
(NO SCOPE)
MATERIALPRODUCTTRADENAMEMODELNUMBER
5'-0" CLEAR
4' -1
1" C
LE
AR
2'-6"
4' -0
5'-0" CLEAR
4' -1
1" C
LE
AR
4' -0
2'-6"
1' -6
" M
IN
C
LE
AR
5'-0" MIN. CLEAR
2' -0
" M
IN
C
LE
AR
4'-0" MIN. CLEAR
Ø5'-0"Ø5'-0"
2'-0" MIN.
CLEAR
1'-10" MIN.
CLEAR
4' -0
" M
IN
. C
LE
AR
4' -6
" M
IN
. C
LE
AR
" M
IN
C
LE
AR
32" MIN.
CLEAR
D-1
D-2
EXISTING SIDEWALK (TO PARKING)
4' -0
2'-6"
1'-4" MIN.
1'-6" MAX.
1'-4" MIN.
1'-6" MAX.
MATERIALPRODUCTTRADENAMEMODELNUMBER
9B
9A
10 10
A
FU
LL
-S
ER
VI
CE
C
IV
IL
E
NG
IN
EE
RI
NG
F
IR
M
W W
W .G
AT
EW
AY
EN
G
IN
EE
RS
.C
TS
BU
RG
H
B
U
TL
ER
5-
4-
PR
EP
AR
ED
F O
R
R
EV
IS
IO
N R
EC
O
R D
N o
D at e
Pa th
F ile na m e=
G :\P ro je ct s\
\6
6\ -0
Fo st er P ar k
AD
A
R es tro om s\ D w g\
-S he et
\A D
A R es tro om R en ov at io n.
dw g Pl ot D at e=
7/
/2
4:
P
M K ay le
M . L an gf or d
Sa ve
D at e= 7/
/2
1:
P M
Project Number:
Drawing Scale:
Date Issued:
Index Number:
Drawn By:
Checked By:
Project Manager:
22.0
G at ew ay E ng in ee rs
In c.
A ll
R ig ht s
R es er ve d
THE GATEWAY ENGINEERS, INC. RETAINS OWNERSHIP RIGHTS OF ALL DATA WITHIN THE PLANS. DATA CONTAINED WITHIN IS ONLY TO BE USED FOR ITS INTENDED PURPOSE BY ITS RESPONSIBLE PARTY. THE USE, REPLICATION, REPRODUCTION, OR REDISTRIBUTION OF DATA CONTAINED WITHIN IS STRICTLY PROHIBITED AND SUBJECT TO LEGAL ACTION. A100
BWF
BWF
AAS/KML
07/17/2026
AS NOTED
C-6106-0008
DEMOLITION PLAN
AND FLOOR PLANS
PI
TT
SB
U
R G
H , P
A
C R
AF
TO
N , P
A
W
P R
O
SP
EC
T
AV
EN
U E
FO
ST
ER
A
VE
N
U E
BO
R
O U
G H
O F
IN
G
R
AM
FO
ST
ER
P
AR
K
R
ES
TR
O
O M
R
EN
O R
E-
BI
D
SCALE:
EXISTING CONDITIONS AND DEMOLITION PLANA100
3/8" = 1'-0"
NOTES:
1. GENERAL CONTRACTOR SHALL PROTECT ALL FINISHES AND ELEMENTS
TO REMAIN DURING DEMOLITION AND CONSTRUCTION.
2. LAYOUT SHOWN IS APPROXIMATE. CONTRACTOR SHALL VERIFY ALL
EXISTING LAYOUTS AND DIMENSIONS IN FIELD.
SCALE:
RESTROOM FLOOR PLANA100
3/8" = 1'-0"
NOTES:
1. ALL PLUMBING FIXTURES AND ACCESSORIES SHALL BE MOUNTED IN
COMPLIANCE WITH ACCESSIBILITY REQUIREMENTS.
2. GENERAL CONTRACTOR SHALL REPAIR AND RESTORE ANY AND ALL
FINISHES DAMAGED DURING CONSTRUCTION.
3. CONTRACTOR TO VERIFY PLACEMENT OF PLUMBING FIXTURES, PARTITIONS
AND ACCESSORIES FOR ACCESSIBILITY COMPLIANCE PER PROVIDED
DRAWINGS AND TYPICAL DETAILS, APPLICABLE CODES AND REQUIREMENTS
OF AUTHORITIES HAVING JURISDICTION.
4. GENERAL CONTRACTOR SHALL PROTECT ALL EXISTING TO REMAIN
ELEMENTS DURING CONSTRUCTION.
SCALE:
RESTROOM ACCESSIBILITY PLANA100
3/8" = 1'-0" SCALE:
RESTROOM ACCESSORY KEY PLANA100
3/8" = 1'-0"
NOTES:
1. ALL PLUMBING FIXTURES AND ACCESSORIES SHALL BE MOUNTED IN COMPLIANCE WITH
ACCESSIBILITY REQUIREMENTS.
2. GENERAL CONTRACTOR SHALL REPAIR AND RESTORE ANY AND ALL FINISHES DAMAGED
DURING DEMOLITION AND CONSTRUCTION.
3. CONTRACTOR TO VERIFY PLACEMENT OF PLUMBING FIXTURES, PARTITIONS AND
ACCESSORIES FOR ACCESSIBILITY COMPLIANCE PER PROVIDED DRAWINGS AND TYPICAL
DETAILS, APPLICABLE CODES AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION.
3'-0"
6' -1
0"
KICK PLATE. SEE
'DOOR HARDWARE
SCHEDULE'
3'-0"
6' -1
0"
REFER TO PLANS
FOR DOOR
SWING DIRECTION
KICK PLATE. SEE
'DOOR HARDWARE
SCHEDULE'
1' -0
3'-4"
2" 3'-0"
7' -0
2"
2" 6'
-1 0"
1' -7
M
AX
3' -0
" M
AX
2' -1
0" M
AX
3' -4
M
AX
TO
R
EF
LE
C
TI
VE
S
U R
FA
C
E
WALL-MOUNTED LAVATORY PER PLANS
FLOOR-MOUNTED TOILET PER
PLANS
4' -0
" M
AX
TO
O
PE
R
AB
LE
E
LE
M
EN
T
4' -0
" M
AX
TO
O
PE
R
AB
LE
E
LE
M
EN
T
-4
1"
12"
MIN.
3'-2"
2" 2'-10"
7' -0
2"
2" 6'
-1 0"
2'-10"
6' -1
0"
1' -0
KICK PLATE. SEE
'DOOR HARDWARE
SCHEDULE'
2'-10"
6' -1
0"
REFER TO PLANS
FOR DOOR
SWING DIRECTION
KICK PLATE. SEE
'DOOR HARDWARE
SCHEDULE'
A
FU
LL
-S
ER
VI
CE
C
IV
IL
E
NG
IN
EE
RI
NG
F
IR
M
W W
W .G
AT
EW
AY
EN
G
IN
EE
RS
.C
TS
BU
RG
H
B
U
TL
ER
5-
4-
PR
EP
AR
ED
F O
R
R
EV
IS
IO
N R
EC
O
R D
N o
D at e
Pa th
F ile na m e=
G :\P ro je ct s\
\6
6\ -0
Fo st er P ar k
AD
A
R es tro om s\ D w g\
-S he et
\A D
A R es tro om R en ov at io n.
dw g Pl ot D at e=
7/
/2
4:
P
M K ay le
M . L an gf or d
Sa ve
D at e= 7/
/2
1:
P M
Project Number:
Drawing Scale:
Date Issued:
Index Number:
Drawn By:
Checked By:
Project Manager:
22.0
G at ew ay E ng in ee rs
In c.
A ll
R ig ht s
R es er ve d
THE GATEWAY ENGINEERS, INC. RETAINS OWNERSHIP RIGHTS OF ALL DATA WITHIN THE PLANS. DATA CONTAINED WITHIN IS ONLY TO BE USED FOR ITS INTENDED PURPOSE BY ITS RESPONSIBLE PARTY. THE USE, REPLICATION, REPRODUCTION, OR REDISTRIBUTION OF DATA CONTAINED WITHIN IS STRICTLY PROHIBITED AND SUBJECT TO LEGAL ACTION. A200
BWF
BWF
AAS/KML
07/17/2026
AS NOTED
C-6106-0008
SCHEDULES AND
DETAILS
PI
TT
SB
U
R G
H , P
A
C R
AF
TO
N , P
A
W
P R
O
SP
EC
T
AV
EN
U E
FO
ST
ER
A
VE
N
U E
BO
R
O U
G H
O F
IN
G
R
AM
FO
ST
ER
P
AR
K
R
ES
TR
O
O M
R
EN
O R
E-
BI
D
DOOR SCHEDULE
MARK COUNT DOOR AND FRAME TYPE DOOR MATERIAL FRAME MATERIAL GLAZING HEIGHT WIDTH HDWR. SET NO.
D1 1 1/A200 HEAVY DUTY H.M. NO 6' - 10" 2' - 10" 1
QTY. ITEM MANUFACTURER PRODUCT FINISH
DOOR HARDWARE SCHEDULE - SET NO. 2
HINGES
CLOSER WITH STOP
HAGAR US 32D
EN
BB1191 (STAINLESS)
281-PS -DA
SILENCERS 608
KICK PLATE 8400 (12" x 32")
SARGENT
SARGENT
IVES
2 PAIR
SCALE:
DOOR AND FRAME DETAILA200
3/4" = 1'-0"
DOOR AND FRAME NOTES:
1) ALL HOLLOW METAL (H.M.) DOOR FRAMES TO BE WELDED, U.N.O.
2) REFER TO SCHEDULE FOR SPECIFIC HARDWARE SETS
3) PROVIDE ANSI/ADA COMPLIANT ALUMINUM THRESHOLDS AND FULL WEATHER STRIPPING AT ALL EXTERIOR DOORS
4) PROVIDE WALL OR FLOOR MOUNTED DOOR STOPS AT ALL NEW DOOR LOCATIONS
5) ALL DOORS AND FRAMES SHALL BE FACTORY PAINTED FROM MANUFACTURER'S FULL COLOR RANGE OR BE FIELD PAINTED.
6) ALL DOORS SHALL HAVE TACTILE ACCESSIBLE SIGNAGE IN ACCORDANCE WITH ANSI/ADA STANDARDS. REFER TO A000 FOR TYPICAL DETAIL AND MOUNTING INFORMATION
US 32D
US 32D
WELDED H.M.
DOOR STOP1 ULINE H-11877SS US 32D
COMMENTS
1 DEAD BOLT SCHLAGE B661P US 26D
SCALE:
TYPICAL ACCESSIBLE FIXTURE AND
ACCESSORY MOUNTING HEIGHTSA200
N.T.S.
PLUMBING ACCESSORY SCHEDULE
ITEM NO. DESCRIPTION
SURFACE-MOUNTED MULTIROLL TOILET TISSUE DISPENSER
SURFACE-MOUNTED SOAP DISPENSER
GRAB BAR - 42" (SATIN FINISH)
FRAMED MIRROR 24"x36" (STAINLESS STEEL)
9B
GRAB BAR - 18" (SATIN FINISH) (VERTICAL MOUNT)
ANSI/ADA COMPLIANT TACTILE MENS ACCESSIBLE RESTROOM SIGNAGE
MANUF. CODE NO.
B-6806x42
BOBRICK B-27460
B-818615
BOBRICK B-290
*S-15597
BOBRICK
*COLOR TO BE SELECTED BY OWNER FROM MANUFACTURER'S FULL RANGE
**REFER TO MANUFACTURER SPECIFICATIONS FOR ANSI/ADA COMPLIANT INSTALLATION
BOBRICK2
GRAB BAR - 36" (SATIN FINISH)7
**B-43949SURFACE MOUNTED PAPER TOWEL DISPENSER AND WASTE RECEPTACLE
SANITARY NAPKIN DISPOSAL BOBRICK B-270
NOTES:
1. ALL PLUMBING FIXTURES AND ACCESSORIES (GRAB
BARS, SOAP DISPENSER, ETC.) SHALL BE MOUNTED IN
COMPLIANCE WITH ANSI/ADA REQUIREMENTS AND
A000 TYPICAL DETAILS.
D2 1 2/A200 NO 6' - 10" 3' - 0" 2WELDED H.M.
SCALE:
DOOR AND FRAME DETAILA200
3/4" = 1'-0"
CONTRACTOR SHALL FIELD MEASURE EXISTING MASONRY
OPENING AND VERIFY DIMENSIONS PRIOR TO CONSTRUCTION
QTY. ITEM MANUFACTURER PRODUCT FINISH
DOOR HARDWARE SCHEDULE - SET NO. 1
HINGES
CLOSER WITH STOP
HAGAR US 32D
EN
BB1191 (STAINLESS)
281-PS -DA
SILENCERS 608
KICK PLATE 8400 (12" x 34")
SARGENT
SARGENT
IVES
2 PAIR
2 PUSH PLATE WITH HANDLE ROCKWOOD 102X70B US 32D
US 32D
US 32D
DOOR STOP1 ULINE H-11877SS US 32D
HEAVY DUTY H.M.
DEAD BOLT SCHLAGE B661P US 26D
2 PUSH PLATE WITH HANDLE ROCKWOOD 102X70B US 32D
BOBRICK
BOBRICK
BOBRICK
ULINE
B-6806x18
B-6806x36
FLOOR MOUNTED SOLID PLASTIC HPL TOILET PARTITIONS WITH STAINLESS STEEL BASE
(7 FEET HIGH)
CONTRACTOR SHALL FIELD MEASURE EXISTING MASONRY
OPENING AND VERIFY DIMENSIONS PRIOR TO CONSTRUCTION
9A ANSI/ADA COMPLIANT TACTILE WOMENS ACCESSIBLE RESTROOM SIGNAGE *S-15598ULINE
BOBRICK DESIGNER SERIES
NOTES:
1) DOORS SHALL PROVIDE 32" MINIMUM CLEAR WIDTH COMPLYING WITH ANSI/ADA REQUIREMENTS.
| Sheets and Views |
| CS COVER SHEET |
| A001 GENERAL NOTES AND ACCESSIBILITY DETAILS |
| A100 DEMOLITION PLAN AND FLOOR PLANS |
| A200 SCHEDULES AND DETAILS |