2-Final Construction Drawings 2027 Phase III Water Replacement Project.pdf

PDF 12 MB Posted

Attached to
2027 Phase III Water Replacement Project
Solicitation number
27-002
Issued by
Utah

About this file

This document comprises the Final Construction Drawings for the 2027 Phase III Water Replacement Project, prepared by the City of Orem Engineering Division in Orem, Utah. The project involves comprehensive water infrastructure improvements across Business Park Drive and 680 South, designed by Tacoma Parkinson (October 2026) with project management oversight from John Wirthlin. The scope of work includes installation of approximately 3,560 linear feet of 12-inch DR-18 C900 waterline, 6,300 linear feet of 8-inch waterline, and 600 linear feet of 6-inch DR-18 C900 waterline, along with 53 water service extensions, connections of 16 existing water services to the new main line, installation of 56 new water services, and placement of 33 new fire hydrants. The construction completion date is October 1, 2027. The drawings encompass 11 utility sheets (UT1-UT11), 4 roadway sheets (RW1-RW4), and 6 detail sheets (D1-D6) depicting exact locations of waterlines, valves, fire hydrants, meter installations, and associated infrastructure modifications including curb and gutter work and asphalt restoration.

The contractor bears responsibility for survey staking within the City's "OREM97" survey datum, utility potholing and location verification, Storm Water Pollution Prevention Plan (SWPPP) development and submission for approval, and maintenance of driveway access during construction. Specifications require all metallic fittings be wrapped in wax tape, with contractor responsibility for greasing, priming, installing profiling mastic, plastic wrap, and tape wrapping of all bolts, nuts, and fittings. High groundwater conditions are anticipated with minimal trench dewatering planned; however, major groundwater requiring well points will be addressed through change order. Field adjustments to waterline locations may be necessary to avoid existing utilities with no price adjustment for incidental changes. Additional requirements include raising all manhole covers and water valves within permanent asphalt patches with concrete collars flush to the new surface, protecting section corners during construction at contractor expense if damaged, and coordinating gas line looping with Dominion Energy (contact: Manny Torres, 801-376-8798) once the project is awarded and two weeks prior to work requiring such looping.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT VICINITY MAP SYMBOLS DRAWING INDEX

LOCATION MAP

ABBREVIATIONS

CITY OF OREM

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

OREM, UT 84057

56 NORTH STATE ST

(801) 229-7107

APPROVAL CITY ENGINEER

APPROVAL COMMUNITY DEVELOPMENT DIRECTOR

DESIGN: TACOMA PARKINSON

DATE: OCT 2026

2000 NORTH

1600 NORTH

1200 NORTH

800 NORTH

400 NORTH

CENTER ST

400 SOUTH

800 SOUTH

1200 SOUTH

1600 SOUTH

2000 SOUTH

W

ES

T

W

ES

T

W

ES

T

W

ES

T

M

AI

N S

T

EA

ST

EA

ST

E

AS

T

GENERAL INFORMATION

PROJECT NUMBER: 27-002

SHEET

TITLENUMBER

TITLE SHEET1

GENERAL INFO AND LOCATION MAP2

UT10-UT11

IRR IRRIGATION

OC ON CENTER

OUTSIDE DIAMETEROD

LIP OF GUTTER

NOT IN CONTRACT

NOT TO SCALE

NIC

NTS

LG

MH MANHOLE

SIDEWALK

TOP OF WALK

TOP OF CONCRETE

TELEPHONE

EOA EDGE OF ASPHALT

END VERTICAL CURVE

FIRE HYDRANT

INSIDE DIAMETER

G

ID

GAS

EVC

FL

FH

FLOW LINE

CONTROL POINT

DUCTILE IRON

END CURB RETURN

EL

ECR

EC END CURVE

ELEVATION

CP

CTV

DI

CABLE TV

TW

W

TYP

WATER

TYPICAL

SW

TC

T

ENGINEERING STATION

POINT OF TANGENCY

POINT ON CURVE

POINT OF INTERSECTION

POLYVINYL CHLORIDE

RIGHT OF WAY

STORM DRAIN

SANITARY SEWER

POINT OF CURVATURE

POLE, POWER

CURB & GUTTER

BEGIN VERTICAL CURVE

CORRUGATED METAL PIPE

CG

CONC

CI

CO

CMP

CAST IRON

CLEANOUT

CONCRETE

BVC

CB

BM BENCH MARK

CATCH BASIN

R/W

SS

SD

STA

PT

PVC

PRV

ASPHALT CONCRETE

BEGIN CURVE

BEGIN CURB RETURN

AC

.BCR

BC

P

POC

PI

PC

S S

EXISTING CATCH BASIN

EXISTING CLEANOUT

EXISTING MANHOLE

EXISTING PRESSURE REDUCER

EXISTING SUMP

EXISTING WATER METER

EXISTING FIRE HYDRANT

EXISTING WATER VALVE

NEW CATCH BASIN

NEW CLEANOUT

NEW MANHOLE

NEW PRESSURE REDUCER

NEW SUMP

NEW WATER METER

NEW FIRE HYDRANT

NEW WATER VALVE

NEW WATER CROSS

NEW WATER TEE

NEW WATER ELBOW

NEW WATER SLEEVE

NEW WATER REDUCER

NEW WATER PLUG

NEW STREETLIGHTEXISTING STREETLIGHT

EXISTING POLE

EXISTING POLE WITH ANCHOR

SECTION CORNER

CONTROL POINT

SIGN

CONIFEROUS TREE DECIDUOUS TREE

CURB, GUTTER & SIDEWALKCG&SW

ROAD CENTERLINERCL

PRESSURE REDUCING VALVE

EXISTING UTILITIES NEW UTILITIES

INVERT ELEVATIONINV

HDPE

REINFORCED CONCRETE PIPERCP

CL CENTERLINE

FO FIBER OPTIC

HIGH-DENSITY POLYETHYLENE

DESIGN ENGINEER TACOMA PARKINSON 229-7314

PROJECT MANAGER JOHN WIRTHLIN 229-7336

SEWER RYAN JOHNSON 229-7481

WATER QUINN FENTON 229-7546

STORM DRAIN RICK SABEY 229-7545

STREETS BILL PETERSON 229-7512

STREET LIGHTS SHAUN BRIDGES 229-7512

SIGNS TRENT MALLINSON 229-7584

TRAFFIC CONTROL TACOMA PARKINSON 229-7314

SWPPP RYAN CASPER 229-7573

CONTACTS

GENERAL NOTES

TOP OF ASPHALTTA

UT1-UT9

680 SOUTH WATERLINE SHEETS

BUSINESS PARK DR WATERLINE SHEETS

ANGLE POINTAP

2027 PHASE III WATER REPLACEMENT

PROJECT

- BUSINESS PARK DR & 680 SOUTH -

1. THE CONTRACTOR IS TO READ AND UNDERSTAND THE M&P SPECIAL

CONDITIONS LOCATED IN THE SPECIFICATIONS. EACH LINE ITEM IS

COVERED IN DETAIL WITH EXTRA INFORMATION THAT MAY NOT BE FOUND

ON THE PLANS. THE CONSTRUCTION COMPLETION DATE IS OCTOBER 1,

2027.

2. UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR IS

RESPONSIBLE TO POTHOLE, LOCATE AND PROTECT ALL EXISTING UTILITIES.

THE CONTRACTOR IS RESPONSIBLE TO POTHOLE EXISTING UTILITIES TO

VERIFY ELEVATION AND LOCATION.

3. THE CONSTRUCTION SURVEY STAKING IS TO BE PROVIDED BY THE

CONTRACTOR. ALL SURVEY ACTIVITIES SHALL BE PERFORMED WITHIN THE

CITY'S “OREM97” SURVEY DATUM, UNLESS OTHERWISE NOTED.

4. THE CONTRACTOR IS REQ'D TO DEVELOP AND IMPLEMENT A STORM

WATER POLLUTION PREVENTION PLAN (SWPPP) ACCORDING TO

SPECIFICATION 01 57 00 BEFORE CONSTRUCTION BEGINS. THE SWPPP IS

TO BE SUBMITTED TO THE CITY OF OREM DEVELOPMENT SERVICES FOR

APPROVAL.

5. HIGH GROUNDWATER CONDITIONS MAY EXIST. THE CONTRACTOR

SHOULD PLAN ON MINIMAL TRENCH DEWATERING. IF MAJOR

GROUNDWATER IS ENCOUNTERED AND WELL POINTS ARE REQUIRED,

THEN WELL POINTS WILL BE ADDRESSED WITH A CHANGE ORDER.

6. THIS PROJECT HAS EXISTING UTILITIES THAT ARE NEAR THE LOCATIONS OF

THE PROPOSED CULINARY WATER MAIN. IT MAY BECOME NECESSARY TO

MAKE FIELD ADJUSTMENTS TO THE EXACT LOCATION OF THE LINES TO

AVOID EXISTING UTILITIES. THE CONTRACTOR SHALL MAKE ADJUSTMENTS

WITH THE PROJECT MANAGER AND ENGINEER. NO PRICE ADJUSTMENT

SHALL BE MADE FOR INCIDENTAL CHANGES.

7. THE CONTRACTOR IS REQ'D TO MAINTAIN DRIVEWAY PARKING ACCESS TO

ALL APARTMENT BUILDINGS, BUSINESSES, HOMES, ETC. DURING

CONSTRUCTION. STEEL PLATES ARE REQ'D WHILE THE NEW CONCRETE

CURES FOR THE CURB, GUTTER, AND SIDEWALK FOR ANY DRIVEWAY

ENTRANCES AFFECTED.

8. THE CONTRACTOR IS RESPONSIBLE TO SURVEY AND LOCATE ALL MANHOLE

COVERS AND WATER VALVES THAT ARE WITHIN THE PERMANENT

ASPHALT PATCH. ALL MANHOLES AND WATER VALVES ARE TO BE RAISED

BY THE CONTRACTOR WITH CONCRETE COLLARS TO BE FLUSH WITH THE

NEW ASPHALT SURFACE.

9. WHENEVER FEASIBLY POSSIBLE THE CONTRACTOR IS REQUIRED TO HAVE

ALL ASPHALT JOINTS PLACED AT THE STRIPING LOCATIONS AND NOT IN

THE WHEEL PATH LOCATIONS.

10. ALL SECTIONS CORNERS MUST BE PROTECTED DURING THE

CONSTRUCTION PROCESS. ANY DAMAGED OR DISTURBED SECTION

CORNERS MUST BE RE-SURVEYED AT THE CONTRACTORS EXPENSE AND

VERIFIED WITH THE CITY SURVEYOR.

11. ROAD CLOSURES WILL ONLY BE ALLOWED WITH APPROVAL FROM THE CITY

ENGINEER. FOR ANY ROAD CLOSURES CONTRACTOR MUST NOTIFY PUBLIC

SAFETY, WASTE MANAGEMENT, POST OFFICE, ANY SCHOOL DISTRICTS

AFFECTED, AND UTA.

12. CONTACT MANNY TORRES AT 801-376-8798 OR

MANNY.TORRES@DOMINIONENERGY.COM TO HAVE GAS LINES LOOPED.

NOTIFY ENBRIDGE OF LOOPING NEEDS ONCE PROJECT HAS BEEN

AWARDED AND 2 WEEKS PRIOR TO START

EXISTING STRUCTURE

OR FACILITY

PROJECT

AREAS

BUSINESS PARK DRIVE AREA

W

W

W

BUSINESS PARK DRIVE

W

W

W

GE

NEV

A

RD

680 SOUTH AREA

S

W

W

W

D1-D6 DETAIL SHEETS

RW1-RW4 BUSINESS PARK DR ROADWAY SHEETS

I-1

680 S

600 S

W

W in

W 12in W 12in W 12inW 12in W 12in W 12in W 12in W 12in W 12inW 12in

W W

SD 12in SD 12in

SD 12in SD 12in

SD

2i n

SD

2i n

SD 10inSD 10in SD 10in SD 10in SD 10in SD 10in

SD 10in

SD 10in

SS

in

SS 8in SS 8in SS 8in SS 8in

SS 10in SS 10in SS 10in SS 10in SS 10in

SS

5i n

SS 15in SS 15in SS 15in SS 15in SS 15in

SS SS

P

P P

PP

P P P P P P P P P P P P P P P

P P P P P P

P

P

P P P P P P P G G G G G G G G G G G G G G

FO

FO FO FO FO FO FO FO FO

FO FO FO FO FO FO FO

FO

FO

FO

FO FO FO FO FO FO FO

FO FO FO FO FO FO FO

FO

FO

FO FO FO FO FO FO FO FO

FO FO FO FO FO FO FO

FO FO FO FO FO FO FO

FO FO FO FO FO FO FO

FO FO FO FO FO FO FO

FH ASSEMBLY

5' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

6" SLEEVE

W

64' OF 12" DR-18 C900 WATERLINE

12" BUTTERFLY VALVE

5' OF 4" DR-18 C900 WATERLINE

4" 45° BEND4" 45° BEND

4" SLEEVE

13' OF 4" DR-18 C900 WATERLINE

4" GATE VALVE

38' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

W

41' OF 6" DR-18 C900 WATERLINE

W W W W W W

266' OF 12" DR-18 C900 WATERLINE

31' OF 12" DR-18 C900 WATERLINE

12" X 4" TEE

12" X 6" TEE

W W W W W

202' OF 12" DR-18 C900 WATERLINE12" X 6" TEE

6" GATE VALVE

BUSINESS PARK DR

REMOVE & DISPOSE OF EXISTING WATER

METER, & CONNECT NEW WATER SERVICE

TO EXISTING WATER SERVICE

4 4

2 5

KILIO INTERNATIONAL

BLENDTEC INC.

SEE SHEETS RW1-RW4 FOR BUSINESS

PARK DR ASPHALT TREATMENT

M

AT

C H

LI

N

E

- U

T1 T

O P

M

AT

C H

LI

N

E

- U

T1 B

TM

M

AT

C H

LI

N

E

- U

T1 B

TM

M

AT

C

H

LI

N E

- U T2

T O

P12.00'

W in

W 12in W 12in W 12in W 12in W 12in W 12in W 12in W 12in

SD

2i n

SD

2in

SD 15in SD 15in SD 15in SD 15in SD 15in SD 15in

SD

5i n

SD

5i n

SS

in

SS

in

SS 15in SS 15in SS 15in SS 15in SS 15in SS 15in SS 15in SS 15in

SS 15in SS 15in SS 15in

SS

SS

SS

P

P

P

P

P P

P P P P P P P

P

P P P P

P P P

G

G

G G G G G G

G

G G G G

FO

W in

FO

FO

FO

FO

FO FO FO FO FO FO FO FO FO FO

FO FO FO FO

FO

FO

FO FO FO

FO

FO

FO FO FO FO FO FO FO FO FOFO FO FO FO FO FO FO FO FO

W W W W W W W

312' OF 8" DR-18 C900 WATERLINE

FH ASSEMBLY

8' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" 45° BEND

FH ASSEMBLY

8" X 12" REDUCER

8" 90° BEND

W

67' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

8" SLEEVE

8" GATE VALVE

6" GATE VALVE

21' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

13' OF 6" DR-18 C900 WATERLINE

W W

99' OF 12" DR-18 C900 WATERLINE

12" X 8" TEE

W

12" X 6" TEE

BUSINESS PARK DR

W

ES

T

6 5

TRI STAR MANUFACTURING

UTDOT MAINTENANCE SHED

SEE SHEETS RW1-RW4 FOR BUSINESS

PARK DR ASPHALT TREATMENT

M

AT

C H

LI

N

E

- U

T1 T

O P

M

AT

C H

LI

N

E

- U

T1 B

TM

10.00'

12.00'

10.00' 10.00'

27' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

W W

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 3 OF 23

OCT 2026

BUSINESS PARK DR UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT1

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

MATCHLINE - UT1 TOP

MATCHLINE - UT4 BTM

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

in

W 12in W

12in W

12in W 12in W 12in W 12in W 12in W 12in W 12in

W 8in

SD

0i n

SD

0i n

SD 10in

SD

SS

in

SS

in

SS 8in SS 8in SS 10in SS 10in SS 10in SS 10in SS 10in SS 10in SS 10in

SS

SS

SS

SS

SS

PP

P P

P

P P

P P P P

P P P P P P

P

P P P P P P P P P P P

P P P

G

G G G G G G G G G G G

G

G G

G G

G G G G G G G G G G G G G

G

FO

FO FO FO

FO

FO FO FO FO FO FO FO FO

FO

FO FO FO FO FO FO FO FO FO FO FO FO

FO

FO

FO

FO

FO

FO FO FO FO

FO

FO FO FO FO FO FO FO FO FO FO

FO

FO

FO

FO

FO

FO FO FO FO FO FO FO FO FO FO FO

SS

in

SS

in

FO FO FO FO FO FO FO FO FO FO FO FO FO FOFO FO FO FO FO FO FO FO FO FO FO FO FO FO

P

P

P P P P P P P P P P P

W W

350' OF 8" DR-18 C900 WATERLINE

5' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

6" SLEEVE

6" GATE VALVE

14' OF 6" DR-18 C900 WATERLINE

13' OF 4" DR-18 C900 WATERLINE

4" 45° BEND

4" 45° BEND

4" SLEEVE

40' OF 6" DR-18 C900 WATERLINE

FH ASSEMBLY

FH ASSEMBLY

6" GATE VALVE

W

42' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

W W

58' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

36' OF 12" DR-18 C900 WATERLINE

W W

106' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

8" GATE VALVE

12" X 8" TEE

W W W W W

224' OF 12" DR-18 C900 WATERLINE

12" X 4" TEE

W W

102' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

BUSINESS PARK DR

W

ES

T

NEW 4" WATER METER VAULT & ASSEMBLY.

SEE DETAILS I & K ON SHEET D3

US SYNTHETIC

SEE SHEETS RW1-RW4 FOR BUSINESS

PARK DR ASPHALT TREATMENT

M

AT

C H

LI

N

E

- U

T1 B

TM

M

AT

C

H

LI

N E

- U T2

T O

P

MATCHLINE - UT2 TOP

MATCHLINE - UT7 TOP

LOOP 2" GAS LINE SEE NOTE 3.

REMOVE EXISTING WATER

METER VAULT & ASSEMBLY.

12.00'

14' OF 4" DR-18 C900 WATERLINE

4" GATE VALVE

W in

W 12in

W 12in

W 12in W 12in W 12in W 12in W 12in W 12in W 12in W 12in

W in W in

W W

SD 12in

SD 12in

SD 12in

SD

2i n

SD

2i n

SD 10in

SD

in

SD 4in

SD 4in SD 4in

SD

in

SD

in

SD 8in SD 8in SD 8in SD 8in SD 8in

SD 8inSD 8in

SD

SS

in

SS

in

SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in

SS

SS SS SS

P

PP

P

P P P

P P P P P P P P P P P P P P

P P P P

P

P

G

G

G G G G G G G G G G G G

G

G G

G G G G G G G G G G G G G G G

G

G

FO

FO

FO FO

FO FO FO FO FO FO FO FO FO FO FO FO FO

FO FO FO FO FO FO FO FO FO FO FO FO FO FO

FO

FO FO FO FO FO FO FO FO FO FO FO FO FO

W in

SS

in

SS

in

G G

P P P P P P P P

P

FO FO FO FO

FO

FO FO FO FO FO FO FO FO FO

FO FO FO FO

FO

FO FO FO FO FO FO FO FO FO

P P P P P P P P P P P P P P

12' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

6" SLEEVE

8' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

6" SLEEVE

6' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

6" SLEEVE

W W

152' OF 12" DR-18 C900 WATERLINE

12" BUTTERFLY VALVE

40' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

W W

W

W

41' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

14' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

408' OF 8" DR-18 C900 WATERLINE

FH ASSEMBLY

12" BUTTERFLY VALVE

3' OF 12" DR-18 C900 WATERLINE

12" BUTTERFLY VALVE

W

12" X 12" TEE

W W W W

178' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

W

75' OF 12" DR-18 C900 WATERLINE

8" GATE VALVE

12" X 8" TEE

W

73' OF 12" DR-18 C900 WATERLINE

6" GATE VALVE

12" X 6" TEE

W

41' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

W W W W

250' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

40' OF 6" DR-18 C900 WATERLINE

BUSINESS PARK DR

W

ES

T

5 3

5 1

7 7

FORTIS SOLUTIONS GROUP

FERGUSON PLUMBING SUPPLY

SEE SHEETS RW1-RW4 FOR BUSINESS

PARK DR ASPHALT TREATMENT

12 12

W

ES

T

M

AT

C H

LI

N

E

- U

T2 B

TM

M

AT

C

H

LI

N E

- U T3

T O

P

12.00'

10.00'

10.00'

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 4 OF 23

OCT 2026

BUSINESS PARK DR UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT24020

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

200 M

AT

C H

LI

N

E

- U

T2 T

O P

M

AT

C H

LI

N

E

- U

T2 B

TM

MATCHLINE - UT 2 TOP

MATCHLINE - UT 5 BTM

MATCHLINE - UT7 BTM

MATCHLINE - UT2 BTM

M

AT

C H

LI

N

E

- U

T2 T

O P

M

AT

C H

LI

N

E

- U

T2 B

TM

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

3. CONTACT MANNY TORRES AT 801-376-8798 OR

MANNY.TORRES@DOMINIONENERGY.COM TO

HAVE GAS LINE LOOPED. NOTIFY ENBRIDGE OF

LOOPING NEEDS ONCE PROJECT HAS BEEN

AWARDED AND AGAIN 2 WEEKS PRIOR TO

WORK THAT REQUIRES LOOP.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

2i n

W

2i n

W 12in W 12in W 12in W 12in

W

2i n

W 12in W 12in W 12in W 12in W 12in

W

W W

SD

2i n

SD

2i n

SD 12in SD 12in SD 12in

SD 10in

SD

8i n

SD

8i n

SD 18in SD 18in SD 18in SD 18inSD 21in SD 21in SD 21in

SD

4i n

SD

4i n

SD

in

SD

in

SD 8in SD 8in SD 8in SD 8in

SD 8in

SD 8in SD 8in SD 8in

SD 8in

SD 8in

SD

SS

in

SS

in

SS 8in SS 8in SS 8in SS 8in

SS 8in

SS

in

SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in

SS

SS

PP PP

P P P P

P P P P P P P P P P P P P P G G G G G G G G G

G G G G G

G G

G

G G G G G G G G G G

G G G G

FO FO FO

FO

FO FO FO FO FO FO FO FO FO FO FO

FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO

FO FO FO FO FO FO FO FO FO FO FO FO FO FO

P P

P P P P P P

P

FO FO FO FO FO FO FO FO FO FOFO FO FO FO FO FO FO FO FO FO

P P P P P P P P P P P P P P

6" 45° BEND

6" 45° BEND

6" SLEEVE

FH ASSEMBLY

12" 45° BEND

12" 45° BEND

W

6" GATE VALVE W

W

12" SLEEVE

12" BUTTERFLY VALVE

3' OF 6" DR-18 C900 WATERLINE

5' OF 12" DR-18 C900 WATERLINE

43' OF 6" DR-18 C900 WATERLINE

32' OF 6" DR-18 C900 WATERLINE

2' OF 12" DR-18 C900 WATERLINE

276' OF 8" DR-18 C900 WATERLINE

33' OF 12" DR-18 C900 WATERLINE

12" BUTTERFLY VALVE

13' OF 12" DR-18 C900 WATERLINE

12" 45° BEND

6' OF 12" DR-18 C900 WATERLINE

12" 45° BEND

W W W

15' OF 12" DR-18 C900 WATERLINE

W W W W

193' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE 12" X 8" TEE

8" GATE VALVE

6" GATE VALVE

12" X 6" TEE

W W W W

12" X 12" TEE

240' OF 12" DR-18 C900 WATERLINE

BUSINESS PARK DR

W

ES

TREMOVE & DISPOSE OF EXISTING WATER METER,

& CONNECT TO EXISTING WATER SERVICE

INSTALL NEW WATER METER & CONNECT TO

EXISTING WATER SERVICE

6 5

7 7

ECHO PARK PAPER CO

UVU PRINTING SERVICES

PEAK FITNESS

SEE SHEETS RW1-RW4 FOR BUSINESS

PARK DR ASPHALT TREATMENT

M

AT

C H

LI

N

E

- U

T2 B

TM

M

AT

C

H

LI

N E

- U T3

T O

P

M

AT

C H

LI

N

E

- U

T3 T

O P

M

AT

C H

LI

N

E

- U

T3 B

TM

12.00' 14.00'

10.00'

W in

W in

W in

W 8in

W 8in

W in W in

W 12in

W 12in

W 12in

W 12in

W 12in W 12in W 12in

W W

SD

12in

SD 12in

SD 12in

SD 12in SD 12in

SD

2i n

SD 15in

SD 18in

SD 18in

SD 18in SD 18in

SD 18in

SD 18in SD 18in SD 18in SD 18in

SD 18in

SD

in

SD 6in

SD 8in

SD 8in

SD 8in

SD 8in

SD 8in SD 8in SD 8in SD 8in SD 8in

SS 8in SS 8in

SS

in

SS

in

SS

in

SS 8in SS 8in

SS 8in

SS 8in

SS 8in

SS 8in

SS 10in

SS 10in

SS 10in

SS 10in

SS

SS

P

P

P P

P

P P

P

P

P

P

PP

P

P P P

P

P

P

P

P P P

P P P P

P

P P

P

P

P

P

P

P

G G G G G G

G

G

G

G

G

G

G

G

G

G

G

G

G G G G G G G

G

G

G

FO

FO

FO FO FO FO FO FO FO

FO

FO

FO

FO

FO

FO

FO

FO FO FO

FO

FO

FO FO FO FO

FO

FO

FO

FO

FO

FO

FO FO FO

FO

FO FO FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO FO FO

FO

FO

FO

FO

FO

FO

P P P P

G G

G G

G G

G

G

G

G

G

W

62' OF 8" DR-18 C900 WATERLINE

8" 11.25° BEND

8" 45° BEND

26' OF 8" DR-18 C900 WATERLINE

8" 22.5° BEND

7' OF 8" DR-18 C900 WATERLINE

5' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" 45° BEND

FH ASSEMBLY

6' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

6" SLEEVE

W

W

W

W

181' OF 12" DR-18 C900 WATERLINE

12" 22.5° BEND

4' OF 12" DR-18 C900 WATERLINE

12" 11.25° BEND

3' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

8" SLEEVE

6" GATE VALVE

W

47' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

32' OF 6" DR-18 C900 WATERLINE

12" X 8" TEE

8" GATE VALVE

W

W

12" BUTTERFLY VALVE

W

W

W W W

240' OF 12" DR-18 C900 WATERLINE

37' OF 12" DR-18 C900 WATERLINE

12" X 8" TEE

13' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

31' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

BUSINESS PARK DR

W

ES

T

REMOVE & DISPOSE OF EXISTING WATER

METER, & CONNECT EXISTING WATER SERVICE

INSTALL NEW WATER METER & CONNECT TO

EXISTING WATER SERVICE

7 7

REDX

MOUNTAINLAND TECHNICAL COLLEGE

SEE SHEETS RW1-RW4 FOR BUSINESS

PARK DR ASPHALT TREATMENT

M

AT

C H

LI

N

E

- U

T3 T

O P

M

AT

C H

LI

N

E

- U

T3 B

TM MAT

CHLIN

E

- U

T3 B

TM

MAT

CHLIN

E

- U

T4 T

OP

M

AT

C H

LI

N

E

- U

T3 B

TM

M

AT

C

H

LI

N E

- U T9

T O

P

14.00'

10.00'

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 5 OF 23

OCT 2026

BUSINESS PARK DR UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT3

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

MATCHLINE - UT8 TOP

MATCHLINE - UT3 TOP

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

in

W in

W in

W 12in

W 12in W 12in

W 12in W 12in W 12in

W 12in

W 12in

W

6i n

W

6i n

W 8in

W 8in

W in

SD

12in

SD 18in SD 18in SD 18in SD 18in

SD 18in

SD

8i n

SD

8i n

SD

18in

SD 18in SD 18in

SD 24in

SD

in

SD 6in

SD 8in SD 8in

SD 8in SD 8in

SD 8in

SD 8in

SD 8i n

SD

SD

SD

SD

SS

8i n

SS 8in

SS 8in SS 8in

SS 8in

SS 10in

SS 10in SS

P

P

P

P

P

PP

P

P P

P P P P P P P P

P

G

G G

G G

G G

G G

G G

G

G

G

G G

G G

G G G G G

G G

G

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

P P

G

G

G

G

G

G G G

G G

G G

G G

G G

G

G

G

G

W

W

W W

W W

166' OF 12" DR-18 C900 WATERLINE

W

64' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

17' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

W W

W W

W

W

12" X 8" TEE

8" GATE VALVE

62' OF 8" DR-18 C900 WATERLINE

8" 11.25° BEND

FH ASSEMBLY FH ASSEMBLY

12" X 6" TEE

8' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

16" X 12" TEE

9' OF 16" DR-18 C900 WATERLINE

16" BUTTERFLY VALVE

170' OF 12" DR-18 C900 WATERLINE

12" BUTTERFLY VALVE

16" SLEEVE

12" BUTTERFLY VALVE

BUSINESS PARK DR

W

ES

T

REMOVE & DISPOSE OF EXISTING

WATER METER, & CONNECT TO

EXISTING WATER SERVICE

INSTALL NEW WATER METER &

CONNECT TO EXISTING WATER SERVICE

CUT & INSTALL NEW 16" X 12" TEE

3 5

DAVA STUDIOS

BLIP BILLBOARDS

SEE SHEETS RW1-RW4 FOR BUSINESS

PARK DR ASPHALT TREATMENT

SIDEWALK IMPROVEMENTS TO

BE INSTALLED BY OTHERS

SIDEWALK IMPROVEMENTS TO

BE INSTALLED BY OTHERS

COORDINATE WITH PROJECT MANAGER TO VERIFY

WATER METER AND NEW FH DO NOT CONFLICT

WITH LOCATION OF THE FUTURE SIDEWALK

ENSURE NEW FH IS LOCATED

BEHIND FUTURE SIDEWALK

G

EN

EV

A

R O

AD

(U

D O

T)

M

AT

C H

LI

N

E

- U

T3 B

TM

M

AT

C

H

LI

N E

- U T4

T O

P

16" SLEEVE

10.00'

W 8in

W 12in

W 12in

SD 12in

SD 12in

SD 12in SD 12in

SD 12in

SD

15in

SD

15in

SS 8in SS 8in SS 8in SS 8in

SS 8in

SS 8in

SS 15in SS 15in

SS 15in SS 15in

SS

P

P

P

PP

P

PP

P

P

P

P P

G G

G

GG

G

G

W 8in W 8in W 8in

W 8in

FO

FO FO

W W

FH ASSEMBLY

38' OF 6" DR-18 C900 WATERLINE

8" 11.25° BEND

6" X 8" REDUCER

W

8" 90° BEND

FH ASSEMBLY

6" GATE VALVEW

W

W166' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

8" GATE VALVE

67' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

8" X 6" TEE

1890 WEST

TCG PRECAST

MATCHLINE - UT4 BTM

MATCHLINE - UT5 TOP

10.00'

WWWWW

223' OF 8" DR-18 C900 WATERLINE

8" X 8" TEE

10.00'

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 6 OF 23

OCT 2026

BUSINESS PARK DR & 1890 W UTILITY PROJECT

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT4

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

M

AT

C H

LI

N

E

- U

T1 T

O P

M

AT

C H

LI

N

E

- U

T4 B

TM

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

3. FOR GENEVA ROAD NIGHT WORK REQ'D. 7"

ASPHALT (OR MATCH EXISTING IF GREATER

THAN 7"), 3' MIN FLOW FILL FROM BOTTOM OF

ASPHALT, T PATCH REQ'D AFTER

CONSTRUCTION, MILL 2" AND OVERLAY TO THE

NEXT LANE LINE WITH 10' ON BOTH SIDES OF

TRENCH. FOR COORDINATION AND OBTAINING

PERMIT, CONTACT DALE FITZHUGH (801)

227-8017.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (38" PG 58-28)

1 12" EDGE MILL (1

2" PG 64-34) WITH 2"

OVERLAY (1

2" PG 58-28)

3" TRAVEL LANE PROFILE MILL (1

2" PG

64-34)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

in

W 8in

SD

2i n

SD

2i n

SD

5i n

SD

5i n

SD

5i n

SD

5i n

SD

5i n

SS

in

SS 8in

SS 8in

SS 8inP

P

P

G G

G

W 8in

8" 90° BEND

6" X 8" REDUCER

26' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

FH ASSEMBLY

W W W W

38' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

6" X 8" REDUCER

8" 11.25° BEND

8" GATE VALVE 166' OF 8" DR-18 C900 WATERLINE

W

ES

T

3 3

TCG PRECAST

VINTAGE GERMAN MOTORS

M

AT

C H

LI

N

E

- U

T4 B

TM

M

AT

C

H

LI

N E

- U T5

T O

P 10.00'

10.00'

W

W 8in W 8in W 8in W 8in W 8in W 8in

W in

W 8in W 8in

W 8in

W in

W in

W

SD

2i n

SD 12in SD 12in SD 12inSD 12in SD 12in

SD 10in SD 10in SD 10in SD 10in SD 10in SD 10in

SD 10in SD 10in

SD

4in

SD 4in

SD

4in

SD

in

SD 8in

SD 8in

SD

SD

SD

SD

SD

SD

SS

in

SS

in

SS

in

SS 8in

SS 8in

SS 8in

SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in

SS

SS

SS

SS

SS

P

P

P P P P P P

P

P P

G G G G G G G

G G

G G

G

G

G G

G G

FO FO FO

FO FO FO

FO

FO

FO

FOFOFO

W in

W 8in W 8in

W in

W 8in W 8in W 8in

W in

P

P P

P P

PPPPPP

G

G

G

G G

W

W 111' OF 8" DR-18 C900 WATERLINE

WWWWWWW

350' OF 8" DR-18 C900 WATERLINE

8" 90° BEND

29' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

6" 45° BEND

6" X 8" REDUCER

6" SLEEVE

W W

100' OF 8" DR-18 C900 WATERLINE

8" 90° BEND

8" 90° BEND

6" X 8" REDUCER

7' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

FH ASSEMBLY

W W

W W

187' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

FH ASSEMBLY

15' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

5' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

8" X 8" TEE

W

42' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

1680 WEST

OPTI-LUBE ADDITIVES

& LUBRICANTS

BLENDTEC INC.

MATCHLINE - UT5 BTM

MATCHLINE - UT6 TOP

10.00'

10.00'

10.00'

10.00'

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 7 OF 23

OCT 2026

1890 W & 1680 W UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT5

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

M

AT

C H

LI

N

E

- U

T

TO

P

M

AT

C H

LI

N

E

- U

T

BT

M

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

SD 10in SD 10in

SD 8in

SD 8in

SS

in

SS

in

SS 8in SS 8in SS 8in SS 8in

SS

SSSS

W in

W 8in W 8in W 8in W 8in

W 8in

W 8in W 8in

W 3/4in

W 3/4in

W in

W in

SS

in

SS

in

SS 8in

SS 8in

SS 8in SS 8in

SS

in

SS

in

SS

in

SS

SSSS

SD 10in

G G G G G G G G G

G

G

W

42' OF 8" DR-18 C900 WATERLINE

8" 22.5° BEND

8" 22.5° BEND

W

9' OF 4" DR-18 C900 WATERLINE

4" 45° BEND

4" 45° BEND

9' OF 4" DR-18 C900 WATERLINE

4" GATE VALVE

4" SLEEVE

FH ASSEMBLY

17' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

W W

8" GATE VALVE 14' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

FH ASSEMBLY

W

60' OF 8" DR-18 C900 WATERLINE

W W

97' OF 8" DR-18 C900 WATERLINE

8" X 4" TEE

7' OF 4" DR-18 C900 WATERLINE

4" 45° BEND

4" 45° BEND

9' OF 4" DR-18 C900 WATERLINE

4" GATE VALVE

4" SLEEVE

111' OF 8" DR-18 C900 WATERLINE

39' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

11' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" X 6" TEE

5' OF 8" DR-18 C900 WATERLINE

8" X 4" TEE 8" X 6" TEE

187' OF 8" DR-18 C900 WATERLINE

21' OF 8" DR-18 C900 WATERLINE

8" X 8" TEE

W

59' OF 8" DR-18 C900 WATERLINE 8" GATE VALVE

WWWWW

226' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

WASTACH CABLE

BUCKET WONDERS

MATCHLINE - UT5 BTM

MATCHLINE - UT6 TOP

M

AT

C H

LI

N

E

- U

T6 T

O P

M

AT

C H

LI

N

E

- U

T6 B

TM

10.00'

10.00'

W 8in

W in

W 8in W 8inW 8in W 8in W 8in W 8in W 8in

W in W in

W in

W 8in

W 3/4in

W 3/4in

W in

W

SS 8in SS 8in

SS 8in SS 8in

SS

in

SS

in

SS

in

SS

2i n

SS

2i n

SS

2i n

SS 12in SS 12in SS 12in

SS 12in

SD

8i n

SD 8in

SD

SD

SD

SD

8" 90° BEND

W

5' OF 8" DR-18 C900 WATERLINE

12' OF 6" DR-18 C900 WATERLINE

FH ASSEMBLY

23' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

14' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

FH ASSEMBLY

4" 45° BEND

4" 45° BEND

4" SLEEVE

W W W

125' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

FH ASSEMBLY

10' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

13' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" 45° BEND

24' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

W W

102' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

6" GATE VALVE

97' OF 8" DR-18 C900 WATERLINE

8" X 8" TEE 8" SLEEVE

8" GATE VALVE

6' OF 4" DR-18 C900 WATERLINE

4" X 8" REDUCER

5' OF 4" DR-18 C900 WATERLINE

MEXAN AUTOMATION

LAKESHORE PLASTICS

M

AT

C H

LI

N

E

- U

T6 T

O P

M

AT

C H

LI

N

E

- U

T6 B

TM

10.00'

10.00'

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 8 OF 23

OCT 2026

1680 W UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT6

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

in W in

W in W in

W in W in

W 12in W 12in W 12in W 12in W 12in W 12in W 12in W 12in W 12in

SD 12in

SD 12

in

SD 12

in

SD 12in SD 12in SD 12in SD 12in

SD

2i n

SD 12in SD 12in

SD

0i n

SD

SD

SD

SD

SS

in

SS

in

SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in

SS

in

SS

in

SS 8in SS 8in SS 8in

SS

P

P P

P

G G G G G G G G G G G G G G G

FO

SD SD SD SD SD SD SD

G G G G G G G G G G

G G G G G

FO FO FO FO FO FO FO FO

FO FO FO FO FO FO FO FO

SD

SD SD SD SD

SD SD SD SD

25' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

FH ASSEMBLY

11' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

W W

W

135' OF 6" DR-18 C900 WATERLINE

6" SLEEVE

32' OF 6" DR-18 C900 WATERLINE

FH ASSEMBLY

6' OF 12" DR-18 C900 WATERLINE

12" 45° BEND

12" SLEEVE

20' OF 12" DR-18 C900 WATERLINE

6" GATE VALVE

8" X 6" TEE

W W

152' OF 12" DR-18 C900 WATERLINE

3' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" 45° BEND

2' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

8" SLEEVE

4' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" 45° BEND

9' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

8" SLEEVE

12' OF 12" DR-18 C900 WATERLINE

12" BUTTERFLY VALVE

W

75' OF 12" DR-18 C900 WATERLINE

12" X 6" TEE

W W W

151' OF 12" DR-18 C900 WATERLINE

1600 WEST

REMOVE & DISPOSE OF EXISTING WATER

METER, & CONNECT NEW WATER SERVICE

TO EXISTING WATER SERVICE

5 5

7 7

US SYNTHETIC

FORTIS SOLUTIONS GROUP 5

M

AT

C H

LI

N

E

- U

T2 T

O P

M

AT

C H

LI

N

E

- U

T7 T

O P

10.00'10.00'

6" GATE VALVE

12" X 6" TEE

12" X 8" TEE

W W W

149' OF 12" DR-18 C900 WATERLINE

12" X 8" TEE

10.00'

W 8in W 8in W 8in W 8in W 8in

W 12in

W 12in

W 12in

W

W W

W

SD

12in

SD 12in SD 12in SD 12in

SD

4in

SD

in

SD

4in

SD

4in

SD

in

SD

in

SD 8in SD 8in SD 8in SD 8in SD 8in SD 8in SD 8in

SD

8in

SD

8in

SD

8in

SD

8in

SD 8in

SD

SD

SD

SD

SD

SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in

SS 8in SS 8in

SS 8in

SS

SS

SS

SS

SS

SS

P

P P

P

P P P P P P

P

P

P

G G

G G

G

G

G G G G G

G G

G

G

G G

G

G

G

G G

G G

G

G G G G G G G

G

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

W 8in W 8in W 8in W 8in W 8in

W

W W

W

P P

P P P P P P

P

P

P

P

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

P

P P

P P

P FH ASSEMBLY

2' OF 6" DR-18 C900 WATERLINE

W W W W W W W W W W

408' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

FH ASSEMBLY

6" GATE VALVE

8" 45° BEND

6" X 8" REDUCER

9' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

8" GATE VALVE

6" SLEEVE

6" 45° BEND

W W

W

W 12" X 8" TEE

1580 WEST

ABANDONED FIRE LINEABANDONED FIRE LINE

FUSION PAIN & COATINGS CO

NORCO INDUSTRIAL

FERGUSON PLUMBING SUPPLY

WASTE MANAGEMENT

10.00'

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 9 OF 23

OCT 2026

1600 W & 1580 W UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT7

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

M

AT

C H

LI

N

E

- U

T7 B

TM

M

AT

C

H

LI

N E

- U T2

B

TM

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

W 6i n

W 12in W 12in W 12in W 12in W 12in

W 12in

W 12in

W 12in

W 12in

W 12in

W in W in

W

SD

2i n

SD

2i n

SD

2i n

SD 12in

SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in

SD

18in

SD 18in

SD

21in

SD

21in

SD

21in

SD

in

SD 8in SD 8in SD 8in SD 8in SD 8in SD 8in SD 8in

SD

8in

SD 8in SD 8in SD 8in SD 8in

SD

8in

SD

8in

SD

8in

SS

in

SS 8in SS 8in SS 8in SS 8inSS 8in

SS 8in

SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in

SS 8in SS 8in

SS 8in

SS

SS

SS

SS

SS

SS

SS

SS

PP

PG

G G

G G

G

G G G G G G G

G G

G G

G

G G

G G

G

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

P

P P P P P P

P P

P P

P

P

P P P P P

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

P P

P P

P

16' OF 8" DR-18 C900 WATERLINE

32' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" 22.5° BEND

8" 45° BEND

W

FH ASSEMBLY

6" X 8" REDUCER

20' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

27' OF 8" DR-18 C900 WATERLINE

8" X 8" TEE

3' OF 8" DR-18 C900 WATERLINE

12' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

FH ASSEMBLY

W

6" GATE VALVE

8" 45° BEND

42' OF 8" DR-18 C900 WATERLINE

W W W W W W

276' OF 8" DR-18 C900 WATERLINE

77' OF 6" DR-18 C900 WATERLINE

8" GATE VALVE

W W

W W

1480 WEST

3 35

REMOVE & DISPOSE OF EXISTING WATER

METER, & CONNECT NEW WATER SERVICE

TO EXISTING WATER SERVICE

CSA HEATING & AIR

ECHO PARK PAPER CO

MATCHLINE - UT8 TOP

MATCHLINE - UT8 BTM

10.00'

8" GATE VALVE

12" BUTTERFLY VALVE

12" X 8" TEE

W in

W in

W 6i n

W in

W in

W in

SD 12in

SD

in

SD

in

SD 8in SD 8in SD 8in

SS

in

SS

in

SS

in

SS 6in SS 6in SS 6in

SSSS

SSSS SS

SS

G G P

P

W 6in W 6in W 6in W 6in

W

W W

104' OF 8" DR-18 C900 WATERLINE

28' OF 8" DR-18 C900 WATERLINE

W W W W W

231' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" 90° BEND

8" 45° BEND

FH ASSEMBLY

8" 45° BEND

6" X 8" REDUCER

4' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

2 2 2 2

33 3

MCNEIL PRINT & PROMOS

APPLIED INDUSTRIAL TECHNOLOGIES

MATCHLINE - UT8 TOP

MATCHLINE - UT8 BTM

10.00'

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 10 OF 23

OCT 2026

1480 W UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT8

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

M

AT

C H

LI

N

E

- U

T3 T

O P

M

AT

C H

LI

N

E

- U

T8 T

O P

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

in

W 8i n

W 8i n

W 8in W 8in

W 8in

W 8in

W 12in

W 12in

W in

W 8i n

W

SD 12inSD 12in

SD 12in

SD 12in

SD 10in

SD 15in

SD 15in

SD

5i n

SD

5i n

SD

5i n

SD

5i n

SD 18

in

SD 18

in

SD 18in

SD 6i n

SD 8i n

SD 8in

SD 8in

SD

SS

in

SS

in

SS 8in

SS 8in

SS 8in

SS 10in

SS 10in

SS 10in

SS 10in SS 10in

SS 10in

SS 10in

SS 10in

SS

SS

SS

SS

SS

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P P

P P

P

P

P

P

P

P

P

P

P

P P

P

P

G

G

G

G

G

G

G

G

G

G

G G

G G

G

G

G

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO FO

FO

FO

FO

FO

FO FO

FO FO FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

W in

G

G

G

G

G G

G

G

22' OF 6" DR-18 C900 WATERLINE

W

W

105' OF 8" DR-18 C900 WATERLINE

8" 22.5° BEND

26' OF 8" DR-18 C900 WATERLINE

8" 22.5° BEND

7' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

W

62' OF 8" DR-18 C900 WATERLINE

8" 11.25° BEND

FH ASSEMBLY

4' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

13' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

6" 45° BEND

6" GATE VALVE

6" X 8" REDUCER

6" SLEEVE

36' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

8" 45° BEND

22' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

8" SLEEVE

W

W

W

47' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

5' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" 45° BEND

6" SLEEVE

12' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

15' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

W

57' OF 8" DR-18 C900 WATERLINE

W

W

92' OF 8" DR-18 C900 WATERLINE

8" X 8" TEE

27' OF 8" DR-18 C900 WATERLINE

8" 45° BEND

14' OF 6" DR-18 C900 WATERLINE

6" 22.5° BEND

8" X 6" TEE

6" SLEEVE

FH ASSEMBLY

3' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

12' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

8" GATE VALVE

6" X 8" REDUCER

5' OF 6" DR-18 C900 WATERLINE

3' OF 6" DR-18 C900 WATERLINE

8" X 8" TEE

1380 WEST

BUSINESS PARK DR

BLIP BILLBOARDS

SFC ENERGY

MATCHLINE - U

T3 BTM

MATCHLINE - U

T4 TOP

M

AT

C H

LI

N

E

- U

T3 B

TM

M

AT

C H

LI

N

E

- U

T9 T

O P

10.00'

10.00'

8" GATE VALVE

12" X 8" TEE

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 11 OF 23

OCT 2026

1380 W UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

BA

SE

M

AP

.D

W G

UT9

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

W 6in W 6in W 6in

W 6in

W 6in

W 6in

W 6in

W in W in

W 6inW 3/4in

W 3/4in

W 3/4in

SD

5i n

SD

5i n

SD 18in SD 18in

SD 18in

SD 18in

SD 18in

SD 18in

SD 18in

SD 18in SD 18in

SD

in

SD

in

SDSD

SS 8in

SS 8in SS 8in SS 8in

SS 8in

SS 8in

SS 8in

SS 8in SS 8in SS 8in

SS

in

SS

in

SS

SS SSSS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

P P

P

P P

P

G G G G G

G

G

G

G

G G G G G G

G G

G G

G G

G

G

G G

G

G G

G

G G

G

G G

G

G G

W

W

W W W

8" X 6" TEE

8" 22.5° BEND

99' OF 8" DR-18 C900 WATERLINE

8" 11.25° BEND

39' OF 8" DR-18 C900 WATERLINE

8" 11.25° BEND

152' OF 8" DR-18 C900 WATERLINE

W

52' OF 6" DR-18 C900 WATERLINE

6" GATE VALVE

W8" X 6" TEE

6" GATE VALVE

34' OF 6" DR-18 C900 WATERLINE

FH ASSEMBLY

6" X 8" REDUCER

6" GATE VALVE

8' OF 6" DR-18 C900 WATERLINE

FH ASSEMBLY

W

8" X 8" TEE

6" CAP

61' OF 8" DR-18 C900 WATERLINE

8" 90° BEND

W W

W

8" GATE VALVE

133' OF 8" DR-18 C900 WATERLINE

W W W

8" GATE VALVE

150' OF 8" DR-18 C900 WATERLINE

4 4

M

AT

C H

LI

N

E

- U

T1

TO

P

M

AT

C H

LI

N

E

- U

T1

BT

M

680 SOUTH

W

ES

T

W

ES

T

9 9

10.00'

10.00'

W 6in W 6in W 6in W 6in W 6in W 6in W 6in W 6in W 6in

W in

W 3/4in

W 3/4in

W 3/4in

W

/4 in

W

/4 in

W 3/4in

W in

SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in

SS

in

SS 8in SS 8in SS 8in SS 8in SS 8in

SS 8in SS 8in SS 8in SS 8in SS 8in

SS 8in

SS

SS

SS

SSSS

SSSS

SS

SS

SS

SSSS

P P P

P P

PP

P P

W in

G G G G G G G G G G G G G G

G

G G

G

G

G G

G

G

G

G

G G

W W

W

W 6" GATE VALVE

44' OF 6" DR-18 C900 WATERLINE

W W W

6" GATE VALVE

8' OF 6" DR-18 C900 WATERLINE

8" X 6" TEE

FH ASSEMBLY

W W W W W W

8" GATE VALVE

266' OF 8" DR-18 C900 WATERLINE

6" CAP

117' OF 8" DR-18 C900 WATERLINE

150' OF 8" DR-18 C900 WATERLINE

8" X 6" TEE

8" TO 8" HOT TAP

4 4

M

AT

C H

LI

N

E

- U

T1

TO

P

M

AT

C H

LI

N

E

- U

T1

BT

M

680 SOUTH

W

ES

T

W

ES

T

W

ES

T

5 5

9 9

9 9

9 9

10.00'

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 12 OF 23

OCT 2026

680 S UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

SO

U

TH

\2 7-

SO

U

TH

B

AS

EM

AP

.D

W G

UT10

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

M

AT

C H

LI

N

E

- U

T1

BT

M

M

AT

C H

LI

N

E

- U

T1

TO

P

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

REMOVE & REPLACE DRIVE APPROACH

W 6in W 6in W 6in W 6in

6in

W 6in

W 6in W 6in W 6in

W in

W W

W

SD

5i n

SD

5i n

SD

8i n

SD

8i n

SD 18in SD 18in SD 18in SD 18in SD 18in SD 18in

SD 18in SD 18in SD 18in

SD

6in

SD

6in

SS 8in SS 8in

SS 8in SS 8in SS 8in SS 8in SS 8in

SS

in

SS

in

SS 8in SS 8in SS 8in SS 8in

SS

SSSS

SS

SS

SS

SS

SSP

P P

P P

P

G G G G G G G G G G G

G

G G

G

G

G

G

G G

W

10' OF 6" DR-18 C900 WATERLINE

8' OF 6" DR-18 C900 WATERLINE

W W W W W W W W W W W W

167' OF 8" DR-18 C900 WATERLINE

273' OF 8" DR-18 C900 WATERLINE

FH ASSEMBLY

6" GATE VALVE

FH ASSEMBLY

6" GATE VALVE

8" GATE VALVE

6" X 8" REDUCER

8" 90° BEND

8" X 8" TEE

8" X 8" TEE

8" X 6" TEE

6" GATE VALVE

5' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6' OF 6" DR-18 C900 WATERLINE

6" 45° BEND

6" SLEEVE

8" GATE VALVE

91' OF 8" DR-18 C900 WATERLINE

15' OF 8" DR-18 C900 WATERLINE

4 4

4 4

680 SOUTH

W

ES

T

9 9

10.00'

W 6in

W 6in

W 6in

W 6in

W 6in

W 6in

W 6in W 6in W 6in

SD 18in

SD 18in

SD 18in

SD 18in

SD 18in

SD 6in

SD 6in

SD

SD

SD

SS 8in

SS 8in

SS 8in

SS 8in

SS 8in SS 8in SS 8in SS 8in SS 8in SS 8in

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

P

P

P

W in

W in

W in

W 6in W 6in W 6in W 6in

G

G

G

G

G

G

G G G G G G G G G

G

G

G

G

G

G

G

G

G G

G

G

G

G

W

W W W

45' OF 8" DR-18 C900 WATERLINE

149' OF 8" DR-18 C900 WATERLINE 33' OF 8" DR-18 C900 WATERLINE

W

W

W

W

W

W

W

8" 11.25° BEND

8" 11.25° BEND

8" 22.5° BEND

8" X 8" TEE

8" GATE VALVE

68' OF 8" DR-18 C900 WATERLINE

W W W W

6" GATE VALVE

8" X 6" TEE

9' OF 6" DR-18 C900 WATERLINE

FH ASSEMBLY

8" GATE VALVE191' OF 8" DR-18 C900 WATERLINE

8" GATE VALVE

6" SLEEVE

6" SLEEVE

8" X 8" TEE

4 4

1030 WEST

9 9

6" X 8" REDUCER

6" X 8" REDUCER

SO

UT

H

10.00'

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 13 OF 23

OCT 2026

680 S & 1030 W UTILITY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

SO

U

TH

\2 7-

SO

U

TH

B

AS

EM

AP

.D

W G

UT11

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

M

AT

C H

LI

N

E

- U

T1

BT

M

H

AL

F M

AT

C

H

LI

N E

- U T1

TO

P H

AL

F

MATCHLINE - U

T11 BTM

MATCHLINE - U

T11 TOP

M

AT

C H

LI

N

E

- U

T1

BT

M

M

AT

C H

LI

N

E

- U

T1

TO

P

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

12.00'

BUSINESS PARK DRM

AT

C H

LI

N

E

- R

W

TO

P

M

AT

C H

LI

N

E

- R

W

BT

M

M

AT

C H

LI

N

E

- R

W

BT

M

M

AT

C H

LI

N

E

- R

W

TO

P

12.00'

BUSINESS PARK DR

W

ES

T

M

AT

C H

LI

N

E

- R

W

TO

P

M

AT

C H

LI

N

E

- R

W

BT

M

10 10 11 11

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 14 OF 23

OCT 2026

BUSINESS PARK DR ROADWAY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

RO

AD

W

AY

S

HE

ET

S.

DW

G

RW1

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

MATCHLINE - RW4 BTM

MATCHLINE - RW1 TOP

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

CROSSES, SADDLES, REDUCERS, ETC.

CONTRACTOR SHALL GREASE/PRIME ALL

BOLTS, NUTS, FITTINGS, ETC., INSTALL

PROFILING MASTIC WHERE NEEDED TO

ELIMINATE VOIDS, INSTALL WAX TAPE, INSTALL

PLASTIC WRAP, AND TAPE WRAP.

2. CONTRACTOR SHALL PRESERVE AND PROTECT

ALL EXISTING TREES WITHIN THE WORK AREA

WHEREVER POSSIBLE. IF SITE CONFLICTS

REQUIRE THE REMOVAL OR HEAVY PRUNING

OF ANY EXISTING TREE THE CONTRACTOR

MUST HAVE APPROVAL FROM THE PROJECT

MANAGER.

HATCH LEGEND:

WATERLINE TEE PATCH 6" THICK

ASPHALT (1

2" PG 58-28)

WATERLINE TEE PATCH 4" THICK

ASPHALT (1

2" PG 58-28)

1 12" EDGE MILL WITH 2" OVERLAY (1

2"

PG 64-34)

3" TRAVEL LANE PROFILE MILL (1

2" PG

58-28)

4" CONCRETE FLATWORK OVER 4"

UTBC

LANDSCAPE & IRRIGATION

RESTORATION

UDOT ROW SEE NOTE 3 FOR

ASPHALT & FILL SPECIFICATIONS

NOTE LEGEND:

REMOVE & ABANDON EXISTING FH ASSEMBLY

CONNECT TO EXISTING WATER SERVICE

EXTEND EXISTING WATER SERVICE

NEW WATER SERVICE

ABANDON EXISTING WATER VALVE

ABANDON EXISTING WATER LINE

REMOVE & REPLACE CURB & GUTTER

REMOVE & REPLACE NEW CROSS GUTTER

REMOVE & REPLACE CURB, GUTTER & SIDEWALK

ADJUST MANHOLE TO FINISHED GRADE

ADJUST VALVE TO FINISHED GRADE

PLUG & CAP EXISTING ABANDONED WATERLINE

BUSINESS PARK DR

W

ES

T

M

AT

C H

LI

N

E

- R

W

BT

M

M

AT

C H

LI

N

E

- R

W

TO

P

M

AT

C H

LI

N

E

- R

W

BT

M

M

AT

C H

LI

N

E

- R

W

TO

P

10 10

1111111111

12.00'

BUSINESS PARK DR

W

ES

T

W

ES

T

M

AT

C H

LI

N

E

- R

W

BT

M

M

AT

C H

LI

N

E

- R

W

TO

P

M

AT

C H

LI

N

E

- R

W

BT

M

M

AT

C H

LI

N

E

- R

W

TO

P

10 11

11 11 1110

CITY OF OREM

OREM, UT 84057

56 NORTH STATE ST

ENGINEERING DIVISION

COMMUNITY DEVELOPMENT

DESCRIPTIONBYREV DATE

PROJECT # DESIGN DRAWN CHECKED PAGE #

27-002 GTP GTP TLN 15 OF 23

OCT 2026

BUSINESS PARK DR ROADWAY SHEET

2027 PHASE III WATER REPLACEMENT PROJECT

Z:

\D

S_

EN

G\

EN

G_

PR

O

JE

CT

S\

\2 7-

P

HA

SE

II

I W

AT

ER

R

EP

LA

CE

M

EN

T

PR

O

JE

CT

\D

ES

IG

N

\D W

G\

BU

IS

N

ES

S

PA

RK

D R\

-0

B

U

SI

N

ES

S

PA

RK

D

R

RO

AD

W

AY

S

HE

ET

S.

DW

G

RW24020

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SCALE: 1" = 40' (11"x 17" SHEET SIZE)

SHEET NOTES:

1. ALL METALLIC FITTINGS NEED TO BE WRAPPED

IN WAX TAPE INCLUDING BENDS, TEES,

C…

This is the start of the file's text. The full file is on GovTribe.