2. PRD Dining DW WS WH Dwgs rev Finals 2023 04 19.pdf

PDF 2 MB Posted

Attached to
Pine Ridge Job Corps Center Dishwasher Replacement Federal contract opportunity
Solicitation number
1282A723Q0056
Issued by
Department of Agriculture Forest Service

About this file

This document package includes construction drawings and specifications for replacing the dishwashers at the Pine Ridge Job Corps Center. The drawings show layouts for installing two new high-efficiency natural gas water heaters, associated valves, piping, venting, and controls. Product cut sheets provide specifications for the water heaters, valves, gauges, and other accessories. Key requirements include 199,000 BTU input water heaters with 100-gallon tanks, parallel plumbing configuration, isolation valves, temperature and pressure gauges, condensate neutralizing kits, and matching gas, water, and vent materials to the existing building systems. The solicitation requests bids for this work in support of the Pine Ridge Job Corps Center Dishwasher Replacement project led by the US Department of Agriculture Forest Service.

View the file

Other files for this federal contract opportunity

Other files attached to Pine Ridge Job Corps Center Dishwasher Replacement, newest first.
File Type Posted
3. PRD Dining ScheduleOfItems-SectionB.pdf PDF
1282A723Q0056.pdf PDF
1. PRD Dining Hall DW WS WH Specs 2023 04 19.pdf PDF
4 WDOL_DBA_NE.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CHADRON, NEBRASKA

PINE RIDGE CCC

PINE RIDGE

CIVILIAN CONSERVATION CENTER

20 MI100

W

W

W

W

W

W

W

H

W

H

W

W

H W

E

E

E

E

E

S

S

E

E

E

E

E E

W

W

W

W

W

HW

GAS

S

UNITED STATES

DEPARTMENT OF AGRICULTURE

FOREST SERVICE

DATENO. REVISION / ISSUE

WATER HEATERS

A. GARRISON, PE

A. CARROLL, PE

P1.0

JOB CORPS

NATIONAL OFFICE

DINING HALL

DISHWASHER, WATER

SOFTENER, AND

WATER HEATERS

PINE RIDGE JOB CORPS

CIVILIAN CONSERVATION

CENTER

NEBRASKA NATIONAL FOREST

04/2023 1

A

P1.0

WATER HEATERS ISOMETRIC, PARALLEL PLUMBED

NO SCALE, SCHEMATIC, RE-USE OF CONFORMING EXISTING MATERIALS IS ACCEPTABLE

WH1

WH2

C

W

WATER HEATER AND ACCESSORIES

PRODUCT

BASIS OF

DESIGN

CERTIFICATIONS SALIENT FEATURES/ADDITIONAL INFORMATION ACCESSORIES AND NOTES

WATER HEATERS

AMERICAN

STANDARD

HE-100-199-NG

NSF 5, ENERGY

STAR

NATURAL GAS HIGH EFFICIENCY DIRECT VENT STORAGE WATER HEATER. 100 GALLON NOMINAL

STORAGE. 199,000 BTU INPUT (NOMINAL). THERMAL EFFICIENCY 0.96+, 100 DEG. F. RECOVERY

RATE: 235 GALLON/HOUR OR GREATER, WARRANTY: MANUFACTURER STANDARD 3 YEAR LIMITED

WARRANTY. GLASSLINED INTERIOR TANK.

FURNISH AND INSTALL SUPPORTS, ADAPTERS, AND OTHER

ACCESSORIES AND INCIDENTAL MATERIALS AS REQUIRED FOR FULLY

FUNCTIONAL SYSTEM. INSTALL WATER HEATERS ON HOUSEKEEPING

BLOCKS.

WATER AND GAS

PIPE

MATCH EXISTING PIPING MATERIALS, MODIFY AS REQUIRED FOR INSTALLATION OF NEW WATER HEATERS, ACCESSORIES, AND OTHER COMPONENTS INDICATED IN THE WATER HEATER DETAIL.

ISOLATION

VALVES

WATTS

LFB6080G2-SS

NSF 61, LEAD

FREE

FULL PORT LEAD FREE BRONZE WITH STAINLESS STEEL TRIM. SIZE TO MATCH PIPE.

PROVIDE PERMANENT TAGS/LABELS FOR ALL VALVES INDICATING

PURPOSE AND AREA SERVED "NW RESTROOM HW ISOLATION" FOR

EXAMPLE

TEMP/PRESSURE

GAUGES

WATTS

LFDPTG-1 3"

NSF 61, LEAD

FREE

LEAD-FREE COPPER BODY, ASME TYPE B OR BETTER ACCURACY. TEMPERATURE RANGE 32-240 F

+/-. PRESSURE RANGE 0-200 PSI. CONTRACTOR HAS OPTION TO INSTALL COMBINATION GAUGES

OR SEPARATE TEMP/PRESSURE GAUGES IN LOCATIONS INDICATED.

PROVIDE WITH REQUIRED PIPE FITTINGS.

EXPANSION

TANK

AMTROL

THERMXTROL

ST-12C-DD

NSF61, ASME

NOMINAL TANK SIZE 6.4 GALLONS w/ ACCEPTANCE FACTOR OF 0.50. SHELL: STEEL, DIAPHRAGM:

HD BUTYL, NSF61, ANTIMICROBIAL LINING, STAINLESS STEEL CONNECTION, 150 PSIG WORKING

PRESSURE,

CONTRACTOR SHALL ADJUST TANK PRE-CHARGE TO MATCH BUILDING

STATIC WATER PRESSURE PRIOR TO PRESSURIZING WATER SYSTEM.

GLOBE OR

THROTTLING

VALVES

MILWAUKEE

VALVE, UP502

SERIES

NSF 61, LEAD

FREE

INSTALLED ON WATER HEATER INLET PIPING FOR PARALLEL PLUMBED WATER HEATER BALANCING, MATCH TO INLET PIPE SIZE. AFTER SYSTEM FLUSHING AND WATER

HEATER TEMPS HAVE STABILIZED, RUN HOT WATER IN MOST DISTANT HOT WATER FIXTURE, MONITOR OUTLET TEMPS FROM WATER HEATERS AND ADJUST VALVES FOR

OUTLET TEMPS WITHIN 5 DEGREES F.

CONDENSATE

NEUTRALIZING

KIT

2"

NEUTRA-SAFE

CN2-220C

NA

2" DIAMETER CLEAR MEDIA TUBE, RATED FOR 199,000 BTUH MINIMUM CONDENSING APPLIANCES. PROVIDE WITH MOUNTING BRACKETS, ADAPTERS, AND NEUTRALIZING

MEDIA.

GAS, WATER,

AND VENT PIPES

NA IPC COMPLIANT

UTILIZE MATERIALS MATCHING EXISTING WHERE ALLOWED BY IPC AND WATER HEATER AND PRESSURE TANK MANUFACTURER'S. PROVIDE DIELECTRIC FITTINGS

BETWEEN DISSIMILAR METALS. PROVIDE FITTINGS, ADAPTERS, AND UNIONS AS REQUIRED FOR INSTALLATION OF NEW PRODUCTS AND CONNECTION TO EXISTING

BUILDING SERVICES TO REMAIN.

BALL VALVE, NORMALLY OPEN, MATCH PIPE SIZE

SWITCH

TEMP/PRESSURE GAUGE

COLD WATER (CW)

HOT WATER (HW)

B

P1.0

PLUMBING LEGEND

NO SCALE

GENERAL NOTES

1. EXISTING INFORMATION SHOWN ON DRAWINGS HAS BEEN TAKEN FROM LIMITED FIELD OBSERVATIONS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BEGINNING WORK.

2. EXISTING GAS PIPE, WATER PIPE, VENT PIPE, AND ELECTRICAL THAT CONFORMS TO THESE DRAWINGS, THE REFERENCED CODES, AND MANUFACTURER'S REQUIREMENTS MAY BE RE-UTILIZED.

3. PHOTOS SHOW EXISTING CONDITIONS SURROUNDING THE AREAS FOR NEW WORK. FILED VERIFY CONDITIONS PRIOR TO BEGINNING WORK.

4. DRAWING IS SCHEMATIC IN NATURE AND IS INTENDED ONLY TO SHOW REQUIRED PRODUCTS AND REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT THE PROJECT IN A NEAT

WORKMANLIKE MANNER THAT DOES NOT OBSTRUCT ANY REQUIRED BUILDING OR EQUIPMENT SUCH AS ELECTRICAL PANELBOARDS AND ALLOWS FOR FULL ACCESS TO PERFORM ROUTINE AND

PREVENTATIVE MAINTENANCE ON INSTALLED EQUIPMENT INCLUDING INTAKE FILTERS, VALVES, CONTROL BOARDS, ETC.

5. THE FOLLOWING TERMS IN ANY COMBINATION RELATING TO THE INSTALLATION OF PRODUCTS/MATERIALS: INSTALL, FURNISH, PROVIDE, OR SIMILAR STATEMENTS; MEAN THAT THE CONTRACTOR IS

RESPONSIBLE FOR THE PROCUREMENT AND INSTALLATION OF THE PRODUCTS UNLESS IT IS SPECIFICALLY DESIGNATED AS A GOVERNMENT FURNISHED ITEM, SUPPLY ONLY PRODUCT, OR SPARE.

KEY NOTES

EACH WATER HEATER SHALL BE ON DEDICATED 120V 15A BRANCH CIRCUIT WITH DISCONNECT SWITCH AT EACH WATER HEATER. FINAL CONNECTION TO WATER HEATERS FROM SWITCH SHALL

BE IN LIQUID TIGHT AC OR MC RACEWAY. ALL OTHER CONDUIT SHALL BE IN EMT RACEWAY. VERIFY EXISTING CONDITIONS AND MODIFY, EXTEND, OR PROVIDE NEW AS REQUIRED FOR

INSTALLATION.

EXHAUST VENT: 2" MINIMUM (3" FOR DEVELOPED VENT LENGTHS EXCEEDING 25') PER MANUFACTURER'S RECOMMENDATIONS. INSTALL CONDENSATE DRAIN WITH NEUTRALIZING KIT FOR EACH

WATER HEATER AND EXTEND TO SUITABLE FLOOR DRAIN OR CONDENSATE PUMP.

INTAKE VENT: 2" MINIMUM (3" FOR DEVELOPED VENT LENGTHS EXCEEDING 25') PER MANUFACTURER'S RECOMMENDATIONS, PROVIDE TRAP/DRAIN IF INSTALLATION IS RECOMMENDED BY

MANUFACTURER.

MODIFY HOT AND COLD WATER PIPING TO PROVIDE APPROXIMATELY EQUAL PIPE LENGTHS AND MATCHING VALVES AND FITTINGS FOR EACH WATER HEATER. PROVIDE GLOBE

(ISOLATION/THROTTLING) VALVES ON THE COLD WATER SUPPLY LINE FOR EACH TANK. PROVIDE FULL PORT BALL VALVE (ISOLATION ONLY) ON THE OUTLET SIDE OF EACH WATER HEATER.

PROVIDE COMBINATION TEMPERATURE AND PRESSURE GAUGES ON THE OUTLET SIDE OF EACH WATER HEATER PRIOR TO ISOLATION VALVE.

MANUFACTURER STANDARD T&P VALVE AND DOWN PIPING BY CONTRACTOR.

EXTEND GAS PIPING TO EACH WATER HEATER, PROVIDE DRIP LEG FOR EACH.

PROVIDE EXPANSION TANK ON COLD WATER SUPPLY PIPE TO WATER HEATERS, DOWNSTREAM FROM COLD WATER SUPPLY ISOLATION VALVE AND UPSTREAM FROM INDIVIDUAL TANK ISOLATION

VALVES.

GAS PIPE (GAS)

AutoCAD SHX Text 4/19/23 13:08 AGARRISON C:\USERS\AGARRISON\BOX\JCENG_PROJECTS\PINERIDGE\B121_DINING\2022 WATERS-DISHW -WATERH\DWGS\WATER HEATERS DWG.DWG; 13:08 AGARRISON C:\USERS\AGARRISON\BOX\JCENG_PROJECTS\PINERIDGE\B121_DINING\2022 WATERS-DISHW -WATERH\DWGS\WATER HEATERS DWG.DWG;13:08 AGARRISON C:\USERS\AGARRISON\BOX\JCENG_PROJECTS\PINERIDGE\B121_DINING\2022 WATERS-DISHW -WATERH\DWGS\WATER HEATERS DWG.DWG; AGARRISON C:\USERS\AGARRISON\BOX\JCENG_PROJECTS\PINERIDGE\B121_DINING\2022 WATERS-DISHW -WATERH\DWGS\WATER HEATERS DWG.DWG;AGARRISON C:\USERS\AGARRISON\BOX\JCENG_PROJECTS\PINERIDGE\B121_DINING\2022 WATERS-DISHW -WATERH\DWGS\WATER HEATERS DWG.DWG; C:\USERS\AGARRISON\BOX\JCENG_PROJECTS\PINERIDGE\B121_DINING\2022 WATERS-DISHW -WATERH\DWGS\WATER HEATERS DWG.DWG;C:\USERS\AGARRISON\BOX\JCENG_PROJECTS\PINERIDGE\B121_DINING\2022 WATERS-DISHW -WATERH\DWGS\WATER HEATERS DWG.DWG;;

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DESIGNER

AutoCAD SHX Text

STAMPS, LOGOS, AND SEALS

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

ARCHIVE NO.

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

DATE

PRD Dining DW WS WH Dwgs rev
P1.0WaterHeaters
Sheets and Views
P1.0WaterHeaters

File details come from the government source that posted it. Updated .