The facility must contain between 870 and 1,145 usable square feet and include the following Air Force-specific spaces: one private office (125 SF), open space for two workstations (125 SF each), one testing/conference room (50 SF) with visibility into the open area, one storage room (60 SF) for supplies and equipment with communications board accommodation, and one additional 30 SF CCTV/security closet. Common areas must include one ADA-compliant restroom and one janitorial closet (minimum 20 SF). All locations must provide secondary egress from individual offices separate from the main entry; 24-hour lighted or secured parking for three government vehicles within the lessor's premises; adequate parking for three service members' privately owned vehicles during working hours plus visitor parking; 24-hour access to leased spaces; and high-speed data service connection from the street to the building demarcation point.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum and Specific Requirements
- 1 -
United States Air Force Career Center
Minimum Usable Square Footage: 870 SF
Maximum Usable Square Footage: 1,145 SF
Minimum Requirements for All Locations:
1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.
2. 24-hour lighted or secured parking within the lessor’s premises for three (3) Government vehicles.
3. Adequate parking for three (3) service member’s privately owned vehicles during working hours as well as for visitors.
4. 24-hour access to the leased spaces.
5. High-speed data service connection from the street to the building demarcation point.
Air Force Specific Requirements:
1. Private Office Space: One Private Office of 125 SF.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for Two (2) workstations, 125 SF each.
3. Testing/Conference Room: One (1) testing room of 50 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board. An additional 30 SF shall be allocated for a separate CCTV/security closet is required.
Minimum and Specific Requirements
- 2 -
Common Area:
1. Restrooms: One (1) located in the common area. Restroom meeting all ADA specifications.
2. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.