This document outlines the minimum and specific requirements for Armed Forces Career Center leased spaces across multiple military service branches.
The facility must contain between 3,850 and 5,133 gross square feet and meet universal requirements including secondary egress from individual offices, 24-hour lighted or secured parking for 15 Government vehicles, adequate private vehicle parking during business hours, 24-hour access to leased spaces, and high-speed data service connections from street to building demarcation point. Service-specific requirements vary by branch: Navy locations require eight workstations, a 100 SF testing/conference room, and 100 SF storage room; USMC locations require four workstations, an 80 SF testing/conference room, and 80 SF storage room; Army locations require ten workstations, an 80 SF testing/conference room, and 80 SF storage room. All service branches require one 125 SF private office with secondary egress. Common areas must include a 54 SF network/CCTV security closet (located in the private office for single-service stations or in common areas for multi-service stations), a minimum of two 100 SF unisex ADA-compliant restrooms, and a minimum 20 SF janitorial closet.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| b. General Clause, GSA Form 3517B.pdf | ||
| 3a. Construction_Specifications_Bid_Proposal_Worksheet.xlsx | XLSX spreadsheet | |
| a. U.S. Government Lease for Real Property.pdf | ||
| 1. Proposal to Lease Space Worksheet.xlsx | XLSX spreadsheet | |
| 3. Construction and Security Specifications.pdf | ||
| 4. Janitorial Services Specification - Requirements.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum and Specific Requirements
- 1 -
Armed Forces Career Center
Minimum Gross Square Footage: 3,850 SF
Maximum Gross Square Footage: 5,133 SF
Minimum Requirements for All Locations:
1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.
2. 24-hour lighted or secured parking within the lessor’s premises for fifteen (15) Government vehicles.
3. Adequate parking for service member privately owned vehicles during working hours.
4. 24-hour access to the leased spaces.
5. High-speed data service connection from the street to the building demarcation point.
Navy Specific Requirements:
1. Private Offices: One (1) private office of 125 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for eight (8) workstations.
3. Testing/Conference Room: One (1) testing room of 100 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 100 SF for supplies/equipment storage, preferably in the rear of the suite.
USMC Specific Requirements:
1. Private Offices: One (1) private office of 125 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.
Minimum and Specific Requirements
- 2 -
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for four (4) workstations.
3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, Army Specific Requirements:
1. Private Offices: One (1) private office of 125 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for ten (10) workstations.
3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, Common Area:
1. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 54 SF for CCTV system and entry control system housing. This closet should be located in the private office if a single Service station or built into the common area if a multiple Service station.
2. Restrooms: A minimum of two (2) unisex 100 SF restroom meeting ADA specifications. Construction specifications will indicate if more than one restroom is required.
3. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.