This file is a Minimum and Specific Requirements document for a United States Marine Corps Career Center lease space. The requirements specify a usable square footage between 1,140 and 1,425 SF, with detailed spatial and functional specifications including a 125 SF private office, open space for 3 workstations, an 80 SF testing room with a glass door, an 80 SF storage room, a 30 SF CCTV/Security closet, and a 20 SF janitorial closet. Additional mandatory requirements include 24-hour secured parking for two government vehicles, adequate parking for service members and visitors, 24-hour space access, high-speed data service connection, ADA-compliant restroom, and secondary egress for offices.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Minimum and Specific Requirements

- 1 -

United States Marine Corps Career Center

Minimum Usable Square Footage: 1,140 SF

Maximum Usable Square Footage: 1,425 SF

Minimum Requirements for All Offices:

1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.

2. 24-hour lighted or secured parking within the lessor’s premises for TWO (2)

Government vehicles.

3. Adequate parking for TWO (2) Service member privately owned vehicles during working hours, as well as for office visitors.

4. 24-hour access to the leased spaces.

5. High-speed data service connection (Fiber is preferred) from the street to the building demarcation point.

USMC Specific Requirements 1,140 SF Min – 1,425 SF Max:

1. Private Office Space: One private office of approximately 125 SF.

2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 3 workstations.

3. Testing Room: One (1) testing room of 80 SF with a glass door facing the open area for test monitoring.

4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board. An additional 30 SF shall be allocated for a separate

CCTV/Security closet is required.

Additional Requirements:

1. Restrooms: ONE (1) located in the common area, restrooms meeting all ADA specifications.

Minimum and Specific Requirements

- 2 -

2. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications. The janitorial closet must be located in the common area.