The document is a Minimum and Specific Requirements file for an Army Career Center lease in Deerfield Beach, FL. The solicitation requires a commercial storefront space between 1,417 and 1,865 gross rentable square feet, located within specified geographic boundaries. Key space requirements include one 100 SF private office, an open area for 5 workstations of approximately 125 SF, an 80 SF testing/conference room, an 80 SF storage room, two ADA-compliant restrooms, and a 20 SF janitorial closet. Additional mandatory features include 24-hour lighted/secured parking for four government vehicles, adequate visitor parking, 24-hour facility access, high-speed data service (preferably fiber), and a secondary office egress. The five-year lease will be a full-service arrangement, with proposals due by 4:00 PM on May 7, 2025, to the Jacksonville District U.S. Army Corps of Engineers, with selection expected approximately 30 days after the proposal deadline.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

- 1 -

Minimum and Specific Requirements

Armed Forces Career Center

Minimum Usable Square Footage: 1,492 SF

Maximum Usable Square Footage: 1,865 SF

Minimum Requirements for All Offices:

1. Secondary egress for office suite leading away from the main entry door.

2. 24-hour lighted or secured parking within the lessor’s premises for FOUR (4)

Government vehicles.

3. Adequate parking for Service member privately owned vehicles during working hours, as well as for office visitors.

4. 24-hour access to the leased spaces.

5. High-speed data service connection (Fiber is preferred) from the street to the building demarcation point.

Army Specific Requirements:

1. Private Offices: One (1) private office of 100 SF within each individual Armed Forces

Center; see specific requirements detailed within the construction specifications.

2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for 5 workstations of approximately 125 SF.

3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.

4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board. An additional 40 SF shall be allocated if separate

CCTV/Security closet is required.

Minimum and Specific Requirements

- 2 -

Common Area Requirements:

1. Restrooms: A minimum of TWO (2) located within the suite; each restroom meeting

ADA specifications built to accommodate at least one at one time.

2. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications. The janitorial closet must be located in the common area.