This document details the minimum and specific requirements for an Armed Forces Career Center lease space with square footage between 5,335 and 7,020 SF. The space must include secondary egresses, 24-hour secured parking for 19 government vehicles, adequate parking for service member vehicles, 24-hour access, and high-speed data connectivity.

The requirements are broken down by military branch, with specific allocations for the Army (1 private office, 10 workstations, training room, testing room), Navy (2 private offices, 4 workstations), Marine Corps (1 private office, 3 workstations), and Air Force (3 workstations). Each branch requires dedicated testing/conference rooms and storage areas of varying sizes. Common areas must include a 15 SF network/CCTV closet, gender-specific ADA-compliant restrooms (male 100 SF, female 64 SF), and a 20 SF janitorial closet. All testing rooms require windows or glass doors facing open areas for monitoring purposes, and storage rooms are to be located preferably in the rear of each suite.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Minimum and Specific Requirements

- 1 -

Armed Forces Career Center

Minimum Gross Rentable Square Footage: 5,335 SF

Maximum Gross Rentable Square Footage: 7,020 SF

Minimum Requirements for All Locations:

1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.

2. 24-hour lighted or secured parking within the lessor’s premises for 19 Government vehicles.

3. Adequate parking for service member privately owned vehicles during working hours.

4. 24-hour access to the leased spaces.

5. High-speed data service connection from the street to the building demarcation point.

Army Specific Requirements:

1. Private Offices: One (1) at 125 SF.

2. Open Space for cubicles or work stations: Space lay out to include an open area within the front of the suite for 10 work stations.

3. Future Soldier Training Room: One (1) at 125 SF.

4. Testing/Conference Room: One (1) testing room of 100 SF with a window or a glass door facing the open area for test monitoring.

5. Storage Room: One (1) storage room of 125 SF for supplies/equipment storage, preferably in the rear of the suite.

Navy Specific Requirements:

6. Private Offices: Two (2) at 125 SF each.

7. Open Space for cubicles or work stations: Space lay out to include an open area within the front of the suite for 4 work stations.

Minimum and Specific Requirements

- 2 -

8. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.

Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite.

USMC Specific Requirements:

9. Private Offices: One (1) at 125 SF.

10. Open Space for cubicles or work stations: Space lay out to include an open area within the front of the suite for 3 work stations.

11. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass

Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, Air Force Specific Requirements:

12. Open Space for cubicles or work stations: Space lay out to include an open area within the front of the suite for 3 work stations.

13. Testing/Conference Room: One (1) testing room of 50 SF with a window or a glass

Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, Common Area:

1. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 15 SF for CCTV system and entry control system housing. This closet should be located in the private office if a single Service station, or built into the common area if a multiple Service station.

2. Restrooms: Two with a male 100 SF and female 64 SF restrooms meeting and ADA specifications.

3. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.