The key requirements include a minimum of 4,788 to a maximum of 5,985 gross rentable square feet of commercial storefront, office, or flex space. The space must include secondary egress, 24-hour secured parking for 15 government vehicles, adequate parking for 19 private vehicles, and 24-hour access. Requirements specific to each military branch are also detailed, such as the need for a private office, open workstations, testing/conference room, and storage space. Common area requirements include two restrooms and a janitorial closet. The solicitation, DACA175250000400, is being issued by the U.S. Army Corps of Engineers Jacksonville District. Proposals are due by 11:59 PM on October 4, 2024, and the government will select the location based on the lowest overall cost. Past performance may also be considered.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum and Specific Requirements
- 1 -
Armed Forces Career Center
Minimum Usable Square Footage: 4,788 SF
Maximum Usable Square Footage: 5,985 SF
Minimum Requirements for All Locations:
1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.
2. 24-hour lighted or secured parking within the lessor’s premises for fifteen (15) Government vehicles.
3. Adequate parking for nineteen (19) service member’s privately owned vehicles during working hours as well as for visitors.
4. 24-hour access to the leased spaces.
5. High-speed data service connection from the street to the building demarcation point.
Army Specific Requirements:
1. Private Office Space: One Private Office of 125 SF.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for eight (8) workstations, 125 SF each.
3. Testing/Conference Room: One (1) testing room of 100 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 100 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board. An additional 30 SF shall be allocated for a separate CCTV/security closet is required.
- 2 -
Navy Specific Requirements:
1. Private Office Space: One Private Office of 125 SF.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for four (4) workstations, 125 SF each.
3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a
Air Force Specific Requirements:
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for two (2) workstations, 125 SF each.
3. Testing/Conference Room: One (1) testing room of 50 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a
USMC Specific Requirements:
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for four (4) workstations, 125 SF each.
3. Testing/Conference Room: One (1) testing room of 50 SF with a window or a glass door facing the open area for test monitoring.
- 3 -
4. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a
Common Area:
1. Restrooms: Two (2) located in the common area. Restroom meeting all ADA specifications.
2. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.