2. Existing Hydronic System.pdf
PDF 170 KB Posted
- Solicitation number
- RFP-171-250000002458-3
- Issued by
- Delta County, Edmore Village, Michigan
About this file
This schematic diagram is a Revised Hydronic System and DOAS (Dedicated Outdoor Air System) Schematic for the State of Michigan, specifically the Department of Health and Human Services (MDHHS) Design and Construction Division. The technical drawing details a complex mechanical system involving heat pumps, air handling units (AHUs), temperature sensors, control valves, and various piping configurations for water treatment, heating, cooling, and ventilation systems. The diagram includes specific equipment like DOAS-1, AHU-1, AHU-2, AHU-3, and multiple pumps and heat exchangers, with a focus on integrating new equipment with existing building automation systems.
The schematic emphasizes several key operational sequences, including maintaining specific temperature controls, managing heating and cooling modes, and ensuring compatibility with the existing building automation system (BAS/DDC). Notable requirements include interfacing new equipment with the central BAS, retaining existing peer-to-peer network controllers, using only current manufacturer products, and ensuring spare parts availability for at least 10 years after contract completion. A specific note highlights the need to separate the fire protection system from the hydronic system, indicating a comprehensive approach to system design and safety integration.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P L U R I B U E
S U N U M
C I R C U M S P I C E
S I QU EREI S P E N I N SU L AM AMOENA M
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
STATE OF MICHIGAN
ROBERT C. HALL, RA, NCARB, DIRECTOR
FACILITIES AND BUSINESS SERVICES ADMINISTRATION
DESIGN AND CONSTRUCTION DIVISION
F
IL
E N
O . 4
/1
.R A
A
IN
D
E X
N O
. 6
WATER
TREATMENT
BF
P
BFP
T-3
T-1 T-2
M
P-1
P-2
P-3
P-4
ET-2
PRV STATION
3/4" MAKE-UP
WATER
4"
3" R-4B
2-1/2"
1-1/2"
2-1/2"
AHU-1
GARAGE AND RECEIVING
GYMNASIUM AHU-2,3
BALANCE VALVE (TYP.)
4" HWR
3"
3"
2-1/2"
HX-1
ET-1
FC-1
4" BYPASS
N.O.
4"
4"
4"
4"
FIRE
PROTECTION
SYSTEM RISER
1" COLD
WATER
R-4
4"
3"
P-5
P-6
P
2"
2" DRAIN
FIRE PROTECTION
BYPASS
CHEMICAL POT FEEDER
FOR PROPYLENE
GLYCOL AND CHEMICAL
TREATMENT OF WATER
N.O.
HIGH LIMIT TO SHUT-
DOWN AT 120°F
4"
PS-1
UH-2
UH-3
T
T
T
DUCTED OA FROM SOFFIT
DUCTED OA FROM SOFFIT
R A
R A
TS-2 PS-2
SA
SA
FACE AND
BYPASS
DAMPERS
FACE AND
BYPASS
DAMPERS
AHU-3
HC-2
AHU-2
HC-3
PRIMARY AIR MEDIUM PRESSURE
DUCT SYSTEM
P
PP
PRESSURE
GAUGE (TYP.) HEAT PUMP
LOOP
CONTROL
M
M M
TS-1
1.2" WC
MANUAL
BALANCING
DAMPER
8"
FILTER PLENUM WITH 8" ROUND
FA INLET AND 14x12 RA OPENING
HEAT
PUMP
FILTER PLENUM WITH 8" ROUND
FA INLET AND 14x12 RA OPENING
HEAT
PUMP
MANUAL
BALANCING
DAMPER
HOSE KIT WITH
AUTOFLOW CV
B-1 B-2
3"
4" 4"
P-7 P-8
HEAT PUMP SUPPLY
OUT TO BUILDING
HEAT PUMP RETURN
OUT TO BUILDING
3" 4"
T-4
T-5
T-6
T-7
UH-1
MIXED AIR
DAMPERS
MIXED AIR
DAMPERS
NEW DISCHARGE
AIR TEMPERATURE
SENSOR
4 4
SPACE
SENSORS
NOTE: EXISTING AIR FLOW
SYSTEM SCHEMATICS SHOWN
ARE FOR REFERENCE ONLY;
EXISTING CONTROLS TO REMAIN.
P-9
SEE ENLARGED DHWG-1
PLAN FOR CONTINUATION
CONTROLLED BY BMS
ENERGIZED ON CALL FOR
DOMESTIC HOT WATER.
PREHEATED
AIR TO COIL
T-8
DOAS-1
54" X 30"54" X 30"
40" X 20"
RHC-1
BarschJ Callout Separate Fire Protection System from Hydronic System