FENCE LOCATION
FREEWAYS
HIGHWAYS
OTHER
CORNER POST
R/W R/W
HIGHWAY
M a x
1’-0"
1’-0"
10’-0" Max10’-0" Max
10’-0" Max
10’-0" Max
10’-0" Max
10’-0" Max
10’-0" Max 10’-0" Max
COUNTY ROUTE
POST MILES
TOTAL PROJECT
SHEET TOTAL
SHEETS
PLANS APPROVAL DATE
No.
Exp.
R E
G I
S T
E R
E
D
P
ROFESSIONA
L
E
N G I
N E
E R
S
T A
TE OF CALIF
ORN
IA
REGISTERED CIVIL ENGINEER
CIVIL
Dist No.
THE STATE OF CALIFORNIA OR ITS OFFICERS
OR AGENTS SHALL NOT BE RESPONSIBLE FOR
COPIES OF THIS PLAN SHEET.
STATE OF CALIFORNIA
DEPARTMENT OF TRANSPORTATION
NO SCALE
CHAIN LINK FENCE
LINE POST
TENSION WIRES
BRACE
BRACE
LINE POST
TRUSS RODS
LINE POST
TENSION WIRES
LINE POST
TRUSS RODS
BRACE
LINE POST
BRACE
LINE POST
TENSION WIRES
DIAGONAL BRACE
STRETCHER BAR
LINE POST
CONCRETE
CONCRETE
THE ACCURACY OR COMPLETENESS OF SCANNED
R
V I S
D
S T
A N
D A
D
P L
A N
S
P
A
CHAIN LINK FENCE ON SHARP BREAK IN GRADE
RODS
TRUSS
RODS
TRUSS
TO ACCOMPANY PLANS DATED
REVISED STANDARD PLAN RSP A85
(SEE NOTE 5)
DETAIL PLANS
OR SHOWN ON
6" OR AS SPECIFIED
(SEE NOTE 5)
DETAIL PLANS
SHOWN ON
SPECIFIED OR
6" OR AS
RODS
TRUSS
8’-0" Max
10’-0" Max 10’-0" Max
VERTICAL STAY
LATCH POSTGATE POST
GATE PANEL
HORIZONTAL BRACE WITH
BRACE
LINE POST
STRETCHER BAR
TENSION WIRES
LINE POST
LENGTH AS SPECIFIED
GATE
CONCRETE
TRUSS TIGHTENERS, Typ
TURNBUCKLE OR
�" TRUSS RODS
Braced line post at intervals not exceeding 1000’
BRACED LINE POST
CHAIN LINK GATE INSTALLATION
BRACED LINE POST INSTALLATION
WITH TRUSS RODS
HORIZONTAL BRACE
DIAGONAL BRACE OR
NO
NO
NO
NO
YES
YES
YES
YES
12"
14"
2’-6"
2’-6"
3’-0"
3’-6"
3’-0"
3’-6"
3’-6"
4’-0"
3 Std
3 Std
3 Std
3 Std
4 Std
5 Std
6 Std
7.58
7.58
7.58
14.60
7.58
9.12
10.80
19.00
12"
12"
12"
14"
18"
20"
4.00"
4.50"
5.56"
6.63"
12"
14"
12"
12"
12"
14"
18"
20"
3� Std
3.50"
3.50"
3.50"
3.50"
(See Notes)
BRACES
TYPICAL MEMBER DIMENSIONS
ROLL FORMED
SECTION
1.35
1.35
1.85
ROLL FORMED
1.875" x 1.625"
(lb/ft)
WEIGHT
OD PIPE
ROUND
(lb/ft)
WEIGHT
(lb/ft)
WEIGHT
6’-0"
(Max)
HEIGHT
FENCE
B (in) L (ft)
SECTION
SECTION
OD PIPE
ROUND
1.35
1.35
1.625" x 1.250"
1.625" x 1.250"
1.625" x 1.250"
1.625" x 1.250"
3.66
1.90"
2.38"
3.662.38"
5.802.88"
3.662.38"
2.38"
2.38"
2.88"
N/A
5.80
3.66 N/A
3.66 N/A
N/A
1.875" x 1.625"
3.250" x 2.500"
3.250" x 2.500"
N/A
N/A
N/A
N/A
2.40
4.50
4.50
2 Std
2 Std
2� Std
2 Std
2 Std
2 Std
2� Std
2.72
3.66
5.80
7.58
9.12
1.90"
2.38"
2.88"
3.50"
4.00"
4.50"
5.56"
6.63" 19.00
10.80
14.60
1� Std
2 Std
3 Std
4 Std
5 Std
6 Std
2� Std
3� Std
5’-0"
8’-0"
10’-0"
5’-0"
6’-0"
8’-0"
10’-0"
NO
NO
NO
NO
YES
YES
YES
YES
2’-6"
2’-6"
3’-0"
3’-6"
3’-0"
3’-6"
4’-0"
3’-0"
14"
12"
12"
14"
18"
20"
8"
10"
SECTION
(lb/ft)
WEIGHT
SLATTED
LINE POSTS
ROUND PIPEROUND PIPE
C l r
GATE POST
USED AS AN ALTERNATE TO A DIAGONAL BRACE
HORIZONTAL BRACE WITH TRUSS ROD MAY BE
9-27-16
2.
3.
4.
5.
1.
6.
NOTES:
Options exercised shall be uniform on any one project.
Specifications may be used upon approval.
Other sections which comply with the strength requirements and other provisions of the
See Revised Standard Plan RSP A85B for Brace, Stretcher Bar, and Truss Tightener Details.
the specifications. Larger or heavier post and brace sizes may be used upon approval.
The table to the right shows minimum sized posts and braces complying with
Sections shown in the tables must also comply with the strength requirements and other provisions of the Specifications.
Offset to be 2’-0" at monument locations, measured at right angles to R/W lines. Taper to achieve offset to be at least 20’-0" long.
Maximum Gate Width is 24’-0".
Larger sizes may be used upon approval.
Above post dimensions and weights are minimums.
B
B
DIMENSIONS TABLE
TYPICAL MEMBER
DEPTH "L" PER
DIMENSIONS TABLE
TYPICAL MEMBER
DEPTH "L" PER
WITH MINIMUM OF 8"
CROSS SECTION OF POST
3 TIMES MAXIMUM
NOT LESS THAN
DIMENSIONS TABLE AND
PER TYPICAL MEMBER
FOOTING WIDTH "B"
DIMENSIONS TABLE
TYPICAL MEMBER
DEPTH "L" PER
POST ASSEMBLY
END AND CORNER
DIMENSIONS TABLE
TYPICAL MEMBER
DEPTH "L" PER
DIMENSIONS TABLE
TYPICAL MEMBER
DEPTH "L" PER
BB
TYPE CL-6 = 6’-0" FABRIC
TYPE CL-4 = 4’-0" FABRIC
B
(lb/ft)
WEIGHT
5’-0"
6’-0"
8’-0"
10’-0"
5’-0"
6’-0"
8’-0"
10’-0"
(Max)
HEIGHT
FENCE ROUND PIPE
SLATTED B (in) L (ft)
OD PIPE
ROUND
SECTION
GATE POST TABLE
DEPTH "L" PER
SECTION OF POST WITH MINIMUM OF 8"
LESS THAN 3 TIMES MAXIMUM CROSS
MEMBER DIMENSIONS TABLE AND NOT
FOOTING WIDTH "B" PER TYPICAL
Singh Sandher Sukhdeep
C74893
12-31-17
1�" Std 2.72
TO ACCOMPANY PLANS DATED
All Rights Reserved c 2017 California Department of Transportation