2.2.1.ii Attachment 2 Pricing Template.xlsx

XLSX spreadsheet 15 KB Posted

Attached to
Fire System Repairs and Inspection Services at the FEMA Selma Transportable Housing Storage Site (THSS)
Solicitation number
70FB8026Q00000026
Issued by

About this file

This is a pricing template for fire system repairs and inspection services at the FEMA Selma Transportable Housing Storage Site (THSS) in Selma, Alabama under solicitation 70FB8026Q00000026. The template is organized into four CLINs with specific pricing requirements for contractors to complete.

CLIN 1 covers fire system repairs and replacement work as a lump sum contract line item. CLIN 2 provides optional times-and-materials pricing with a not-to-exceed amount for additional repairs, including specific line items for jockey pumps, fire pump control panels, fire hydrants, and associated labor for installation and electrician work. CLIN 3 establishes inspection and maintenance services across a base period and four option periods, with detailed quarterly, monthly, and annual inspection requirements including wet sprinkler inspections (4 quarterly), annual fire pump tests, monthly fire pump run tests (12 annually), backflow preventer inspections, fire extinguisher checks for 30 units, fire hydrant testing and lubrication for 6 hydrants, and comprehensive fire alarm system testing. CLIN 4 addresses any other future maintenance as needed with a $30,000.00 cap per period. The template shows a five-year total contract value of $150,000.00 ($30,000.00 per option period including the base period), though specific unit pricing for CLIN 3 inspection services and CLIN 1 repair work must be completed by contractors in the light blue cells designated for pricing input.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Federal Emergency Management Agency (FEMA)
Pricing Template
Fire System Repairs and Inspecion Services at the FEMA Selma Transportable Housing Storage Site (THSS)
CLIN 1DescriptionPriceQuantityTotal Price
0001Selma THSS Fire System Repairs/ Replacement1$0.00
Optional CLIN 2Description
0002Additional Repair/Replacement (Times and Materials) Not to Exceed Amount (NTE) (Optional - As Needed)1$0.00
0002AAJockey Pump
0002BBJockey Pump Controller
0002CCFire Pump Control Panel
0002DDFire Hydrant, Control Valve, & Bolt Packs
0002EELabor: Fire Hydrant Installation
0002FFLabor: Pump & Controller Installation
0002GGLabor: Electrician Work
0002HHAny Other Material If Needed
CLIN 3Description
0003Fire System InspectionsBase PeriodOption Period 1Option Period 2Option Period 3Option Period 4
0003AAQuarterly Wet Sprinkler Inspection (there is one sprinkler system in the main warehouse, with 3 Tampers and 3 Flows).4$0.004$0.004$0.004$0.004$0.00
0003BBAnnual Fire Pump Test1$0.001$0.001$0.001$0.001$0.00
0003CCMonthly Fire Pump Run Test12$0.0012$0.0012$0.0012$0.0012$0.00
0003DDAnnual Backflow Preventer Inspection & Test1$0.001$0.001$0.001$0.001$0.00
0003EEAnnual Fire Extinguisher Checks (there are a total of 30 fire extinguishers, class A, B, and C. All Fire Extinguishers are the same)1$0.001$0.001$0.001$0.001$0.00
0003FFAnnual Fire Hydrant Test, Flush, & Lubrication of 6 Fire Hydrants located on site1$0.001$0.001$0.001$0.001$0.00
0003GGAnnual Fire Alarm Test/Inspection of the Site Fire Alarm System which includes:

-Fire Pump Churn Test -1 Zone -5 Duct Detectors -9 Pull Stations.

-Honeywell & Gamewell Alarm Panels1$0.001$0.001$0.001$0.001$0.00
Total CLIN 3 per Period of Performance$0.00$0.00$0.00$0.00$0.00
Optional CLIN 4Description
0004Any Other Future Maintenance (Optional - As Needed)$30,000.001$30,000.00$30,000.001$30,000.00$30,000.001$30,000.00$30,000.001$30,000.00$30,000.001$30,000.00
TOTAL Base Period$30,000.00TOTAL Option Period 1$30,000.00TOTAL Option Period 2$30,000.00TOTAL Option Period 3$30,000.00TOTAL Option Period 4$30,000.00
TOTAL$150,000.00