This is a Description of Requirement for Supplies document for the Alpena CRTC Munitions Section detailing the procurement of an ordnance deformer system.
The government seeks one stationary electric ordnance deformer unit capable of processing spent cartridges up to and including 20mm at a throughput rate of 8,000 to 11,000 pounds per hour depending on cartridge size and mix. The equipment must include an infeed conveyor with electric drive and catch hopper, a high-speed rotary drum grinder with hood, chute, and soft start, a discharge conveyor with electronic drive, a control panel, and system integration. The available electrical supply is 120/208 volts, 3-phase. The procurement also includes one installation, setup, and training group consisting of on-site training, equipment setup, and system calibration to meet government specifications, as well as shipping of the equipment. All equipment and services must comply with DESR 6055.09 91-201, Edition 1, Change 1, effective February 23, 2024, specifically paragraph V4.E5.18 and all sub-paragraphs. This standard establishes requirements that demilitarization processing equipment must be tested to contain overpressure, fragment, and thermal hazards; screened and segregated materials; operated within manufacturer specifications; and properly inspected and maintained. DoD Components and DAF installations must follow specific guidance documents including DoDM 4140.72, DAFMAN 21-201, and technical orders for procedures related to screening, operation, inspection, maintenance, and disposition of processed materials. Explosives safety siting requirements vary based on whether operations are located outside or within Inhabited Building Distance arcs from Potentially Exposed Sites.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions and Answers W50S8626QA006 - CAO 10 June 2026.pdf | ||
| Solicitation - W50S8626QA006.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESCRIPTION OF REQUIREMENT – SUPPLIES
Ordnance Deformer
The Alpena CRTC Munitions Section
To be acceptable to the government, the requirement must comply with DESR 6055.09 91-201, Edition 1, Change 1, February 23, 2024, paragraph V4.E5.18 and sub paragraphs. (see below)
Ordnance Deformer, Stationary Electric – 1ea.
ORDNANCE DEFORMER, STATIONARY UNIT, PROCESSES SPENT CARTRIDGES UP TO AND
INCLUDING 20MM AT 8,000 TO 11,000 LBS PER HOUR DEPENDING ON SIZE AND MIX OF
CARTRIDGES.
INCLUDES:
INFEED CONVEYOR, ELECTRIC DRIVE, INCLUDES INFEED CATCH HOPPER HIGH SPEED ROTARY
DRUM GRINDER, INCLUDES HOOD, CHUTE AND SOFT START. DISCHARGE CONVEYOR,
ELECTRONIC DRIVE. CONTROL PANEL AND SYSTEM INTEGRATION.
CURRENT ELECTRIC AVAILABLE IS 120/208 VOLT, 3 PHASE
Installation Set up and training – 1 group. On site training/set up of equipment and calibrate system to meet government specifications.
Shipping – 1 ea.
DESR 6055.09 91-201, Edition 1, Change 1, February 23, 2024, paragraph V4.E5.18 and sub paragraphs for informational purposes only:
V4.E5.18.1. A demilitarization operation for processing expended .50-caliber and smaller cartridge cases can be treated as a non-explosive operation provided:
V4.E5.18.1.1. Cartridge casings to be processed are screened prior to processing. Screening is intended to ensure that only .50-caliber and smaller are processed, and to remove unused .50-caliber and smaller cartridges.
V4.E5.18.1.2. Demilitarization processing equipment is tested to be capable of containing overpressure, fragment, and thermal hazards associated with a worst-case reaction involving a single live round of the most energetic cartridge that could be processed in the equipment.
V4.E5.18.1.3. Demilitarization processing equipment is operated within the manufacturer’s specifications and restricted only to the processing of expended .50-caliber and smaller cartridge casings.
V4.E5.18.1.4. Demilitarization processing equipment is inspected and maintained to ensure safe operation.
V4.E5.18.2. The DoD Components must:
V4.E5.18.2. (Added)(DAF) Installations will follow guidance as specified in DoDM 4140.72: (T- 0)
V4.E5.18.2.1. Approve the use of specific demilitarization processing equipment. V4.E5.18.2.1.
(Added)(DAF) Commanders will approve the use of demilitarization equipment that meets the requirements of paragraph V4.E5.18.1.2.
V4.E5.18.2.2. Establish and implement procedures for:
V4.E5.18.2.2.1. Screening and segregating the material to be processed.
V4.E5.18.2.2.1. (Added)(DAF) Units will follow guidance and procedures in DoDM 4140.72, item technical data, DAFMAN 21-201, and T.O. 11A-1-60. (T-0) V4.E5.18.2.2.2. Operating, inspecting, and maintaining the demilitarization processing equipment to ensure safe operation.
V4.E5.18.2.2.2. (Added)(DAF) Units will follow manufacturers’ instructions and develop locally written instructions specific to their installation for the type(s) of demilitarization equipment utilized. (T-0) Follow guidance in paragraph V1.E6.12. for locally written instructions. (T-1)
V4.E5.18.2.2.3. Dispositioning of processed material.
V4.E5.18.2.2.3. (Added)(DAF) Units will establish procedures for the management and disposition of materials in accordance with DoDM 4140.72, DoDD 5134.01, DoDM 4160.21, DoDI 4160.28, DoDI 4140.62, DAFMAN 21-201, and AFMAN 32-7002. (T-0)
V4.E5.18.3. Explosives safety siting requirements are:
V4.E5.18.3.1. Demilitarization processing operation locations meeting the requirements of paragraphs V4.E5.18.1. and V4.E5.18.2., and located outside of IBD from all PESs, do not require submission of a site plan to the DDESB as addressed in paragraph V1.E5.3.9.
V4.E5.18.3.2. Locations used for demilitarization processing operations that are located within IBD arcs:
V4.E5.18.3.2.1. Require submission of a site plan to the DDESB.
V4.E5.18.3.2.2. Must be sited at ILD, except from the PES to which it is integral.