2-Bid Sheet Required Tests and Proposed Fees (Revised 3-17-2026).xlsx

XLSX spreadsheet 18 KB Posted

Attached to
Sprinkler, FDC, and pump testing and related maintenance at Milwaukee Mitchell International Airport
Solicitation number
ITB-2026-Sprinkler, FDC, and pump testing and related maintenance at Milwaukee Mitchell International Airport
Issued by
Milwaukee County, Mattoon Village, Wisconsin

About this file

This is a bid sheet for required tests and proposed fees related to sprinkler, FDC (fire department connection), and pump testing and maintenance services at Milwaukee Mitchell International Airport in Wisconsin. The contract encompasses weekly, annual, three-year, and five-year inspection and maintenance schedules for fire suppression systems at the airport's main facility located at 5300 S. Howell Ave., Milwaukee, WI 53207. A mandatory pre-bid meeting is scheduled for Monday, June 8th, 2026 at 9:00 AM Central Time at the Milwaukee County Milwaukee Mitchell International Airport Fire Department (5800 S. Howell Ave., Milwaukee, WI 53207), unless bidders have completed the required work within the last 18 months. The bid sheet document outlines the specific tests required and allows bidders to propose their fees for performing these services according to the established testing schedule.

The revised bid sheet (dated March 17, 2026) serves as the pricing proposal mechanism for this contract opportunity, requiring bidders to submit their proposed fees for each category of testing and maintenance work. The document establishes the framework for fee submission and comparison among competing bidders, enabling the airport authority to evaluate cost proposals alongside compliance with the mandatory testing requirements and schedules. This procurement allows the airport to solicit competitive pricing while ensuring all required fire safety inspections and maintenance activities are performed in accordance with applicable codes and regulations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fire Alarm Locations

GMIA- Grounds
BuildingAlarm SystemAll buildings are Simplex unless specified
Air Freight Cargo Upper Level
Air Freight Cargo Lower Level
Firehouse Deck Level
Firehouse Main Level
Cold StorageAttached to Firehouse Simplex
IAB Lower Level
IAB Main Level
Powerhouse Deck Level
Powerhouse Main Level
Regulator Building Ground Floor
Regulator Building Basement
Combined Maintenance Ground Level
Combined Maintenance Mezz Levels
Parking Lower Level
Parking Admin Office
Parking Structure Levels 1-6
Terminal Basement Level
Main Terminal Ground Level
Main Terminal Gate Level
Terminal Mezz Level
Terminal Level 5
Terminal Smoke Hatches
Cessna Pump House
Mezz and Baggage Matrix
College Ave TunnelSimplex/ Protect-o-wire"Protectowire Fire system 2000" Ahern Fire Protection
Total of 33 NODES

Fees

Sprinkler, FDC, and Pump Tests/Fees
Bid Sheet Required Tests and Proposed Fees: Must be completed and uploaded to "Requested Information" for continued consideration.Fill in White Squares only
Building NameLocationDescriptionTypeSystemsCommentsRequired TestAnnual Price3 year Price5 Year PriceWeeklyWeekly (Nov-Mar)Fall Drain/Winterization
Per YearPer 3 Year TestPer 5 Yr TestPer WeekPer Week (Nov-Mar)Per Year
Firehouse Main LevelGMIASprinkler SystemWet System1Annual/ 5 Yearxx
Cold StorageGMIASprinkler SystemDry System1Annual/ 5 Yearxx
Powerhouse- MezzanineGMIASprinkler SystemDry System1Annual/ 5 Yearxx
Powerhouse- Ground Level, SW cornerGMIASprinkler SystemWet System1Annual/ 5 Yearxx
College Ave Tunnel- EastGMIASprinkler SystemDry System1Annual/ 5 Yearxx
College Ave Tunnel- WestGMIASprinkler SystemDry System1Annual/ 5 Yearxx
College Ave West- DrainGMIASprinkler SystemDry System1Weekly Draining of dry system condenstaion/Heater CheckWeekly (Nov-Mar)x
Air Cargo WayGMIASprinkler SystemWet System1Annual/ 5 Yearxx
Combined Maintenance- Airport MaintenanceGMIASprinkler SystemWet System1Annual/ 5 Yearxx
Combined Maintenance- Highway (Center Building)GMIASprinkler SystemWet System1Annual/ 5 Yearxx
Combined Maintenance- FleetGMIASprinkler SystemWet System1Annual/ 5 Yearxx
Concourse C- Hammerhead RM C150GMIASprinkler SystemWet System2Annual/ 5 Yearxx
Concourse C- Stem RM 130/ East and WestGMIASprinkler SystemWet System2Annual/ 5 Yearxx
Concourse C- M201GMIAWater CurtainWet System1Annual/ 5 Yearxx
Concourse D- Stem, Gate D35, RM D106GMIASprinkler SystemWet System7Annual/ 5 Yearxx
Concourse D- Hamerhead South, RM D115AGMIASprinkler SystemWet System4Annual/ 5 Yearxx
Concourse D- Hamerhead North, RM D175GMIASprinkler SystemWet System1Annual/ 5 Yearxx
Concourse D- RM 200C, behind TSA podiumGMIAWater CurtainWet System1Annual/ 5 Yearxx
Concourse E/ New Itnter. Building- RM 294AGMIAWater CurtainWet System1Annual/ 5 Yearxx
Parking Admin Office/CPSGMIASprinkler SystemWet System1Annual/ 5 Yearxx
Main Terminal- Stair 1,2, 5, 7, and 9GMIASprinkler System/FDC ConnectedWet System1Stair 2,5,and7 are Standpipes connected to the same loopAnnual/ 5 Yearxx
Main Terminal- Basement, RM 1GMIASprinkler SystemDry SystemTo Include area under floor in confrence room hallwayAnnual/ 5 Yearxx
Baggage Matrix- Outside screening RoomGMIASprinkler SystemDry System13Annual/ 5 Yearxx
Baggage Matrix- RM T114GMIASprinkler SystemDry System1Annual/ 5 Yearxx
Parking Structure Levels 1-6GMIAStandpipeDry System714 FCD's Per FloorAnnual/ 3 Year/Winterizationxxx
Baggae Road way CenterGMIAStandpipeDry System1Hook ups on either end- 3 FDC along the runAnnual/ 3 Yearxx
Admininstartion Building/MCSOGMIAStandpipeDry System22- FDC LocationsAnnual/ 3 Yearxx
Main Terminal-Basement- HMS HostGMIAStandpipeDry System1Stair 20, RM 6/3- Main connection is South TickettingAnnual/ 3 Yearxx
Main Terminal-Basement- Center Island- StorageGMIAStandpipeDry System1Center of ticketting sideAnnual/ 3 Yearxx
Cessna Pump HouseGMIAFire PumpAnnual, Weeklyxx
BLD 120 Pump HouseMKE Buisness ParkFire PumpAnnual, Weeklyxx
BLD 220MKE Buisness ParkSprinkler SystemWet System12- Risers, 1st floor, and 2nd floorAnnual/5 Yearxx
Freight Runners- BLD 217MKE Buisness ParkSprinkler SystemWet System12- Water CannonAnnual/5 Yearxx
Total$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
Total (Five Years)$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0$ - 0
Total 5 Year Price
Extra FeesPrice
Straight Time Hourly Charge
After Hour Hourly Charge
***4 Hour Emergency Response Time***
***No Truck Charge***

File details come from the government source that posted it. Updated .