2-Attachment 8-Drawings.pdf

PDF 18 MB Posted

Attached to
Interior Renovations Board of Education Central Office 50 Nye Road
Solicitation number
GL-2027-05
Issued by
Hartford County, Connecticut

About this file

This architectural drawing set, prepared by Silver Petrucelli + Associates for the Town of Glastonbury Board of Education, documents the interior renovations for the Central Office located at 50 Nye Road, Glastonbury, Connecticut 06033. The project encompasses comprehensive renovations to both lower and upper floor levels of an approximately 28,069 square-foot facility, with a bid set dated June 12, 2026. The scope of work includes demolition plans and reflected ceiling plans for both levels, new architectural layouts, plumbing systems, mechanical systems, and electrical systems including lighting and power distribution. A non-mandatory pre-bid meeting is scheduled for August 17, 2026 at 11:00 AM at the project site. The drawing set designates the building as mixed-use occupancy with Business (B) and Storage (S-1) classifications, constructed to Type IIB construction standards with existing sprinkler systems throughout.

Bidders must be licensed, qualified general contractors prequalified through the Connecticut Department of Administrative Services Contractor Prequalification Program. Each bid requires bid security in the form of a bond certified at not less than 10 percent of the base bid, with the successful bidder required to provide performance and labor and material payment bonds in the full amount of the contract price. The project is subject to prevailing wage requirements under Connecticut General Statutes Section 31-53 and state spending allocation goals and contract compliance requirements including non-discrimination requirements enforced by the Connecticut Human Rights Office. The drawings provide comprehensive code information based on the 2021 Connecticut State Building Code, 2021 IBC, 2021 IPC, 2020 NFPA 70, 2017 ICC A117.1, and 2021 IEBC standards, with detailed specifications for accessibility compliance, fire-rated separations, egress capacity, and plumbing fixture requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SILVER PETRUCELLI + ASSOCIATES

3190 WHITNEY AVENUE, HAMDEN CT 06518

311 STATE STREET NEW LONDON, CT 06320

PHONE 203 230 9007 silverpetrucelli.com

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

PROJECT LOCATION:

PROJECT TITLE:

ARCHITECT

SILVER PETRUCELLI + ASSOCIATES

3190 WHITNEY AVENUE, HAMDEN CT 06518

311 STATE STREET NEW LONDON, CT 06320

PHONE 203 230 9007 silverpetrucelli.com

M/E/P/FP ENGINEERS

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

REDESIGN BID SET: 06/12/2026

FULL SCALE PRINT: 30"x42"

SILVER

203 230 9007

3190 WHITNEY AVENUE HAMDEN

silverpetrucelli.com

CT 06320

ASSOCIATESPETRUCELLI +

CT 06518

311 STATE STREET NEW LONDON

Attachment 8

S.Liu

GENERAL INFORMATION

G100 Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:

Scale:

Drawn By:

Project Number:

Drawing Number:

SILVER PETRUCELLI + ASSOCIATES

203 230 9007

3190 WHITNEY AVENUE HAMDEN CT 06518

silverpetrucelli.com

311 STATE STREET NEW LONDON CT 06320

Project Phase:

25-106

06/12/2026

BID SET

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

As Indicated

- COVER SHEET

GENERAL:

G100 GENERAL INFORMATION

G101 CODE INFORMATION

G102 CODE PLAN

ARCHITECTURAL:

A010 LOWER LEVEL DEMOLITION PLAN

A011 UPPER LEVEL DEMOLITION PLAN

A020 LOWER LEVEL DEMOLITION RCP

A021 UPPER LEVEL DEMOLITION RCP

A110 LOWER LEVEL PLAN

A111 UPPER LEVEL PLAN

A112 ROOF PLAN AND DETAILS

A250 LOWER LEVEL REFLECTED CEILING PLAN

A251 UPPER LEVEL REFLECTED CEILING PLAN

A490 WALL TYPES AND CASEWORK

A850 DOOR SCHEDULE AND DETAIL

PLUMBING:

P001 NOTES, LEGENDS & ABBREVIATIONS

P010 LOWER LEVEL DEMOLITION

P011 UPPER LEVEL DEMOLITION

P100 LOWER LEVEL NEW WORK

P101 UPPER LEVEL NEW WORK

P300 PLUMBING SCHEDULES

P400 PLUMBING DETAILS

MECHANICAL:

M001 NOTES, LEGENDS & ABBREVIATIONS

M010 LOWER LEVEL DEMOLITION PLAN

M011 UPPER LEVEL DEMOLITION PLAN

M110 LOWER LEVEL PLAN

M111 UPPER LEVEL PLAN

M112 ROOF PLAN

M300 DETAILS

M301 DETAILS

M400 SCHEDULES

ELECTRICAL:

E001 NOTES, LEGENDS & ABBREVIATIONS

E010 LOWER LEVEL DEMOLITION PLAN - LIGHTING

E011 UPPER LEVEL DEMOLITION PLAN - LIGHTING

E020 LOWER LEVEL DEMOLITION PLAN - POWER

E021 UPPER LEVEL DEMOLITION PLAN - POWER

E110 LOWER LEVEL PLAN - LIGHTING

E111 UPPER LEVEL PLAN - LIGHTING

E210 LOWER LEVEL PLAN - POWER

E211 UPPER LEVEL PLAN - POWER

E212 ROOF LEVEL PLAN - POWER

E501 PANEL & LIGHT FIXTURE SCHEDULES

E601 DETAILS

BRICK

CONCRETE

CONCRETE MASONRY UNIT (CMU)

RIGID BOARD INSULATION

INSULATION (BATT)

EARTH

GYPSUM BOARD

PLYWOOD

WOOD FRAMING (THROUGH MEMBER)

WOOD FRAMING (INTERRUPTED MEMBER)

ACOUSTICAL TILE OR PANEL

WOOD TRIM/FINISH

DRAWING NUMBER

CX

DETAIL NUMBER

CONSTRUCTION NOTE

ROOM NUMBER

WINDOW TYPE

DX DEMOLITION NOTE

DOOR NUMBER

EXISTING DOOR

NEW DOOR

DOUBLE LEAF DOOR

DOOR W/ 180 HOLD OPEN

UNEQUAL LEAF DOOR

TWO-WAY DOOR

EXISTING DOOR TO BE REMOVED

ROOM NAMEROOM NAME

ACT-1

ROOM IDENTIFICATION

CEILING PLAN

ROOM IDENTIFICATION

ROOM NAME

MATERIAL - HEIGHT

CB1

18"

PRE-MANUFACTURED

CASEWORK SYMBOL

CABINET TYPE

NOMINAL HEIGHT/WIDTH

SPECIAL DEPTH &/OR EQUIP.

EX EQUIPMENT SYMBOL

POCKET DOOR

BI- FOLDING DOOR

SLIDING DOOR

DOUBLE ACTING DOOR

CPT-1

ROOM NAME

FINISH FLOOR PLAN

ROOM IDENTIFICATION

ROOM NAME

MATERIAL - RM NUMBER

SQ FTSQ FT

ROOM NAME

ROOM NUMBER

ABBREVIATIONS (NOT ALL ARE USED) GRAPHIC SYMBOLS MATERIAL CONVENTIONS

DOOR INDICATIONS

METAL FRAMING

X

AXXX

SIGNAGE SYMBOL

TX TOILET ACCESSORY SYMBOL

W

XX

STOREFRONT TYPESF

XX

CURTAIN WALL TYPECW

XX

DRAWING NUMBER

DRAWING NUMBER

REVISION CLOUD & MARK

WALL / PARTITION TYPE

BUILDING SECTION

SECTION/DETAIL

x x

COLUMNS (EXISTING)

DETAIL CALL OUT

"XX" DRAWING NUMBER

"#" INTERIOR ELEVATION

LABEL

ELEVATION

ELEVATION MARKER

DATUM POINT

DRAWING NUMBER

WALL SECTION

X

AXXX

X

AXXX

X

AXXX

X

AXXX

AXXX#

X

X

AXXX

"XX" DRAWING NUMBER

"#" EXTERIOR ELEVATIONAXXX

NORTH ARROW

XX

EXISTING-TO-REMAIN WINDOW,

STOREFRONT, OR CURTAIN WALLETR

A.B. ANCHOR BOLT

ABV. ABOVE

A/C AIR CONDITIONING

A.C.P. ASBESTOS CEMENT PIPE

ACT ACOUSTICAL CEILING TILE

AD. AREA DRAIN

ADJ. ADJUSTABLE

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM. ALUMINUM

ANOD ANODIZED

APPROX. APPROXIMATE

ARCH. ARCHITECT(URAL)

ASPH. ASPHALT

AVG. AVERAGE

BC BRICK COURSE

B/C BOTTOM OF CURB

BD. BOARD

B.E.J BRICK (BLOCK) EXPANSION JOINT

B.F. BOTTOM OF FOOTING

BIT. BITUMINOUS

BLDG. BUILDING

BLK. BLOCK

BLKG. BLOCKING

BM BEAM

B.M. BENCH MARK

B.O. BOTTOM OF

BRG. BEARING

BRK. BRICK

B.S. BOTH SIDES

BSMT. BASEMENT

B.U.R. BUILT UP ROOFING

B/W BOTTOM OF WALL

B.W.R. BOTH WAYS WALL

CAB CABINET

C.B. CATCH BASIN

C. BD. CHALK BOARD

C.B.R. CATCH BASIN TO BE REMOVED

C.C. CURB CUT

CEM CEMENT

CER CERAMIC

C.F.M.F. COLD FORMED METAL FRAMING

CG CORNER GUARD

C.H. CABINET HEATER

CHKBD CHALKBOARD

C.I. CAST IRON

C.I.P. CAST IN-PLACE CONCRETE

C.J. CONTROL/CONSTRUCTION JOINT

CLG. CEILING

CLG. HT. CEILING HEIGHT

CLOS. CLOSET

CLR CLEAR

CLRM CLASSROOM

CMU CONCRETE MASONRY UNIT

CNTR COUNTER

C.O. CLEAN OUT

COL COLUMN

CONC. CONCRETE

CONF. CONFERENCE

CONN CONNECTION

CONSTR. CONSTRUCTION

CONT. CONTINUOUS, CONTINUE

CONTR. CONTRACTOR

CORR. CORRIDOR

CP CONTROL PANEL

CPT CARPET

C.R. CEILING REGISTER

CT CERAMIC TILE

CT CONNECTICUT

CTR CENTER

C.U.H. CABINET UNIT HEATER

C.Y. CUBIC YARD

DBL DOUBLE

DEPT DEPARTMENT

DET. DETAIL

DF DRINKING FOUNTAIN

DIA. DIAMETER

DIFF DIFFUSER

DIM. DIMENSION(S)

DISP DISPENSER

DIV DIVISION

D.L. DEAD LOAD

DN DOWN

D.O. DOOR OPENING

DP DAMP PROOFING

DR. DOOR

DS DOWNSPOUT

D.S.P. DRY STAND PIPE

DTL. DETAIL

DWG, DWGS DRAWING(S)

DWL DOWEL

E EAST

EA. EACH

ECTR. EXISTING CEILING-TO-REMAIN

ED. EDUCATION

E.F. EACH FACE

EIFS EXTERIOR INSULATION & FINISH SYSTEM

E.J. EXPANSION JOINT

E.J.C. EXPANSION JOINT COVER

EL. ELEVATION

ELEC. ELECTRICAL

ELEV. ELEVATION

EMER. EMERGENCY

ENCL. ENCLOSURE

ENGR ENGINEER

ENL. ENLARGED

ENT. ENTRANCE

EP. EPOXY PAINT

EQ. / = EQUAL(S)

EQUIP EQUIPMENT

ES. EXPOSED STRUCTURE

E.T.R. EXISTING-TO-REMAIN

E.W. EACH WAY

E.W.C. ELECTRIC WATER COOLER

E.W./E.F. EACH WAY/EACH FACE

EXAM. EXAMINATION

EXH EXHAUST

EXIST. EXISTING

EXP. EXPANSION

EXPO EXPOSED

EXT. EXTERIOR

F.A. FIRE ALARM

F.A.P. FIRE ALARM PANEL

F.B. FOOTING BREAK

PART PARTITION

P.C.B. PAINTED CONCRETE BLOCK

P.G.B. PAINTED GYPSUM BOARD

PL. OR PLAM PLASTIC LAMINATE

PLUMB. PLUMBING

PLYWD. PLYWOOD

PREFAB PREFABRICATED

PREP. PREPARATION

PROJ PROJECTION

PROP PROPERTY

P.T., PR. TR. PRESSURE TREATED

PTD PAINTED

P.V.C. POLYVINYL CHLORIDE

QT QUARRY TILE

R. RISER

R OR RAD. RADIUS

RB RESILIENT BASE

RCP REFLECTED CEILING PLAN

R.D. ROOF DRAIN

RECPT RECEPTACLE

REF REFERENCE

REFG REFRIGERATOR

REINF. REINFORCEMENT

REQ'D REQUIRED

RES RESILIENT

RET RETAINING

REV REVISION

R.H. ROOF HATCH

RI RHODE ISLAND

R.L. ROOF LEADER

RM. ROOM

R.O. ROUGH OPENING

R.O.W. RIGHT OF WAY

R.T. RUBBER TILE

RV ROOF VENT

R.W.L. RAIN WATER LEADER

S SOUTH

S. STORM

SAN. SANITARY

SB SMART BOARD

SC SEALED CONCRETE

S.C. SOLID CORE

SCHED. SCHEDULE

S.D. SOAP DISPENSER

SECT. SECTION

SF SQUARE FEET

S.FPRG. SPRAYED-ON FIREPROOFING

S.G.F.T. STRUCTURAL GLAZED FACING TILE

SHR SHOWER

SIM. SIMILAR

SK SKETCH

S.N.D. SANITARY NAPKIN DISPENSER

S.N.R. SANITARY NAPKIN RECEPTACLE

S.O.G. SLAB-ON-GRADE

SPEC. SPECIFICATIONS

SPKLR SPRINKLER

S.P.R. SINGLE PLY ROOF

SQ. SQUARE

SQ. FT. SQUARE FEET

SS SOLID SURFACE

SSTL STAINLESS STEEL

STA STATION

STD STANDARD

STIFF STIFFENERS

STL. STEEL

STRUCT. STRUCTURAL

SUSP. SUSPENDED, SUSPENSION

S.W. SHEAR WALL

S.W.F. SHEAR WALL FOOTING

SYM SYMMETRICAL

SYS.,SYST. SYSTEM

T. TELEPHONE

TB TACKBOARD

T&B TOP & BOTTOM

TBD TO BE DETERMINED

TECH. TECHNOLOGY

TEMP TEMPERED

TERR TERRAZZO

TEL TELEPHONE

THK THICK

THRES THRESHOLD

T.O. TOP OF

T.O.F. TOP OF FOUNDATION

T.O.S. TOP OF STEEL

T.P. TOILET PARTITION

T.P.D. TOILET PAPER DISPENSER

T/S TOP OF SLAB

T.T.F. TRIM TO FIT

T/W TOP OF WALL

TYP. TYPICAL

UL UNDERWRITERS LABORATORIES

UNO UNLESS NOTED OTHERWISE

UON UNLESS OTHERWISE NOTED

V.B. VINYL BASE

VCT VINYL COMPOSITE TILE

VERT. VERTICAL

VIF VERIFY IN FIELD

VT VERMONT

W WEST

W. WATER

W/ WITH

MA MASSACHUSETTS

WB WHITE BOARD

WC WALL COVERING

WCJ WALL CONTROL JOINT

WD. WOOD

WF. WIDE FLANGE

WIN. WINDOW

W/O WITHOUT

WOM WALK-OFF-MAT

WP WATERPROOFING

WS WOOD STAIN

W.W.F WELDED WIRE FABRIC

W.W.M. WELDED WIRE MESH

& AND

∠ ∡ ANGLE

@ AT

℄ CENTERLINE

= EQUAL(S)

⌀ DIAMETER

F.BRK FACE BRICK

FD FLOOR DRAIN

FDN. FOUNDATION

F.E. FIRE EXTINGUISHER

F.E.C. FIRE EXTINGUISHER & CABINET

F.F. FINISHED FLOOR

F.H. FIRE HYDRANT

F.H.P. FULL HEIGHT PARTITION

FFE, FF&E FURNITURE, FIXTURES, AND EQUIPMENT

FIN. FINISH, FINISHED

FIXT. FIXTURE

FL. FLOOR

FLASH FLASHING

FLEX FLEXIBLE

F.O.F. FACE OF FINISH

F.O.G. FACE OF GYPSUM BOARD

F.O.M. FACE OF MASONRY

F.O.S. FACE OF STUD

F.O.T. FACE OF TILE

F.P. FIRE PROOF / FIRE PROTECTION

FPFG FIREPROOFING

F.R. FIRE RATED

FRP FIBERGLASS REINFORCED PANEL

F.S. FAR SIDE

FT. FOOT OR FEET

F.T. FIRE TREATED

FTG FOOTING

F.T.R. FINNED TUBE RADIATION

FUR FURRING

G GAS

GA. GAGE, GAUGE

GALV. GALVANIZED

G.B. GRAB BAR

G.C. GENERAL CONTRACTOR

GEN. GENERAL

GFB GROUND FACE BLOCK

GL GLASS

GND GROUND

GRD GRADE

GYP. GYPSUM

GWB GYPSUM WALL BOARD

GYP. BD. GYPSUM BOARD

H.B. HOSE BIBB

H.C. HANDICAP(PED)

H.C. HOLLOW CORE

HD. HEADED

HDWR. HARDWARE

HGT. HEIGHT

HM HOLLOW METAL

HORIZ. HORIZONTAL, HORIZONTALLY

H.P. HIGH POINT

HR. HOUR

HTG HEATING

H.U. HEATING UNIT

HVAC HEATING / VENTILATION / AIR CONDITIONING

HWD HARDWOOD

HYD. HYDRANT

ID INTERIOR DESIGN

I.D. INSIDE DIAMETER

IN. INCH

INCL. INCLUDE OR INCLUDING

INSUL. INSULATION, INSULATED

INT. INTERIOR

INV. INVERT

JAN. JANITOR

JNT/JT JOINT

JST JOIST

K.D. KNOCK DOWN

KIT KITCHEN

K.P. KICK PLATE

LAM. LAMINATE(D)

LAV LAVATORY

LBS POUNDS

LCKR LOCKER

L.F. LINEAR FOOT

LG. LONG

L.L. LIVE LOAD

LOC. LOCATION

L.P. LOW POINT

LTG. LIGHTING

LVL. LEVEL

LVT LUXURY VINYL TILE

M MINUTE

MAS. MASONRY

MATL MATERIAL

MAX. MAXIMUM

M.C. MASONRY COURSE

MECH. MECHANICAL

M.H. MANHOLE

MIN. MINIMUM

MIR MIRROR

MISC. MISCELLANEOUS

M.O. MASONRY OPENING

MTD. MOUNTED

MTL. METAL

MULL MULLION

N NORTH

N.A. NOT APPLICABLE

NH NEW HAMPSHIRE

N.I.C. NOT IN CONTRACT

NJ NEW JERSEY

NO. NUMBER

NOM. NOMINAL

N.P.S. NOMINAL PIPE SIZE

N.R.C. NOISE REDUCTION COEFFICIENT

N.S. NEAR SIDE

N.T.S. NOT TO SCALE

NY NEW YORK

NYC NEW YORK CITY

O/A OUTSIDE AIR

O.C. ON CENTER

O.C.C. OCCUPANT

O.D. OUTSIDE DIAMETER

OFF OFFICE

O.H. OPPOSITE HAND

OPNG. OPENING

OPP OPPOSITE

O.W.S.J. OPEN WEB STEEL JOIST

OZ OUNCE

PA PENNSYLVANIA

GENERAL NOTES

NEW WALL

EXISTING WALL TO BE REMOVED

TYPICAL WINDOW

EXISTING WALL

WINDOW WALL

RECESSED ITEM

WALL INDICATIONS

DRAWINGS LIST

RESERVED ACCESSIBILITY SYMBOL

(OLD TERM "HANDICAPPED")

S#

1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS & DIMENSIONS PRIOR TO FABRICATION, FURNISHING & INSTALLATION OF ANY MATERIALS, EQUIPMENT AND WORK.

2. ALL MATERIALS & EQUIPMENT SHOWN ARE NEW TO BE PROVIDED BY CONTRACTOR(S) UNLESS OTHERWISE NOTED.

3. ALL EXISTING UTILITIES & EQUIPMENT LOCATIONS ARE APPROXIMATE - CONTRACTOR(S) SHALL FIELD VERIFY &/OR COORDINATE EXACT LOCATIONS.

4. CONTRACTOR ASSUMES ALL RESPONSIBILITY DURING CONSTRUCTION TO PROTECT MATERIALS & EQUIPMENT. ANY & ALL DAMAGED ITEMS & EQUIPMENT DURING CONSTRUCTION SHALL BE REPLACED AT NO ADDITIONAL COST TO THE OWNER.

5. ALL RATED DOORS & DOORS FRONTING A CORRIDOR SHALL HAVE POSITIVE LATCHING LOCKSETS UNLESS OTHERWISE INDICATED ON THE DOOR SCHEDULE.

6. ALL DOORS EXITING 50 PERSONS OR MORE SHALL HAVE PANIC EXIT DEVICES.

7. ALL HANDICAP ACCESSIBLE DOOR HARDWARE SHALL BE PROVIDED TO COMPLY WITH ADA, ANSI, & ALL OTHER APPLICABLE CODES.

8. ALL NEW & EXISTING EXPOSED/VISIBLE GUARDRAILS, HANDRAILS, DOOR FRAMES, GLAZING FRAMES, DECKING, BEAMS, COLUMNS, JOISTS & OTHER STRUCTURAL COMPONENTS SHALL BE PAINTED UNLESS OTHERWISE NOTED.

9. ALL CONTRACTORS SHALL REVIEW DRAWINGS & PROJECT MANUAL. IF THERE IS A DISCREPANCY BETWEEN THE TWO (2) OR ANY OTHER PARTS OF THE DOCUMENTS, THE HIGHER VALUE (IN DOLLARS) SHALL PREVAIL AS THE SCOPE OF WORK THAT WILL BE PRICED UNLESS OTHERWISE DIRECTED IN WRITING BY THE ARCHITECT DURING THE BIDDING PERIOD.

10. PATCH ALL EXISTING WALLS & OTHER SURFACES AFFECTED BY DEMOLITION & REMOVALS WITH MATERIALS TO MATCH EXISTING.

11. SAW CUT & REMOVE PORTIONS OF CONCRETE SLAB AS REQUIRED TO ACCOMMODATE NEW PLUMBING, ELECTRICAL, MECHANICAL & OTHER TRADES WORK. COORDINATE LOCATION, WIDTH, & DEPTH OF TRENCHING WITH M/E/P DRAWINGS FOR SCOPE OF NEW

WORK REQUIRED.

12. WALL OPENINGS RESULTING FROM REMOVAL OF DUCTS, PIPES, CONDUITS, ETC. SHALL BE INFILLED WITH MATERIALS TO MATCH THE WALL. SEE M/E/P DEMOLITION DRAWINGS FOR REMOVALS.

13. WHERE NEW DUCTS, PIPES, & CONDUITS PASS THROUGH NEW & EXISTING WALLS, PROVIDE OPENING & HEADER AS REQUIRED & SEAL THE PERIMETER OF THE PENETRATION FOR SOUND TRANSMISSION RESISTANCES & FIRE RATING WHERE INDICATED ON CODE PLANS & OTHER DRAWINGS. COORDINATE WITH M/E/P/FP DRAWINGS FOR ALL OPENINGS REQUIRED.

ENTRY

WORK SPACE

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

214 OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

JAN.

SUPPLY CLOSET

H.C. TOILET

ELEC.

C201AMEN'S TOILET

WOMEN'S TOILET

CORRIDOR

C203

OFFICE

OFFICE

OFFICE

221OFFICE

OFFICE

223OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

OFFICE

OFFICE

OFFICE

231 OFFICE

OFFICE

VESTIBULE

LOBBY

235CONFERENCE ROOM

MEN'S TOILET

236WOMEN'S TOILET

KITCHEN

C205A

H.C. TOILET

STOR.

STOR.

234A

ELEC. CLOSET

C206A STOR.

C206B

STOR.

C206C

STOR.

C204A

15 SF

CORRIDOR

C207

CORRIDOR

C200

CONFERENCE ROOM

1671 SF

CORRIDOR

C201

CORRIDOR

C202

KITCHEN

C202B

CORRIDOR

C204

CORR.

C205

KITCHEN

C200A

CORRIDOR

C206

STAIR

ST1.2

STAIR

ST2.2

ELEVATOR

EL1.2

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6

EX.7 EX.8

EX.X

OFFICE

CORRIDOR

C100

IT STORAGE

STORAGE

SUMP PUMP

CONFIDENTIAL STORAGE

SUMP PUMP

STORAGE

105A

SUMP PUMP

105B

SCIENCE KIT STORAGE

H.C. TOILET

WELLNESS

H.C. TOILET

CORRIDOR

C102

STORAGE

FOR PUPIL SERV.

TIS

DATA TEAM

OFFICE

OFFICE

OFFICE

OFFICE

BREAKOUT AREA

OFFICE

OFFICE

OFFICE

118 OFFICE

OFFICE

VEST.

ELECTRICAL

STORAGE

SAFE ROOM

SAFE ROOM

STORAGE

FOR BUSINESS

STORAGE

FOR BUSINESS

STORAGE

FOR BUSINESS

WORK SPACE

DATA

MEN

VEST.

ELEC.

C100A

ELEC.

CLOSET

C104A

ELEV. MACH.

C104B

STOR.

C106A

WOMEN

133A

OFFICE

CORRIDOR

C103

STOR. CLOSET

C102A

CORR.

C104

KITCHEN

115A

CORRIDOR

C105

CORRIDOR

C106

CORRIDOR

C107

STAIR

ST1.1

STAIR

ST2.1

ELEVATOR

EL1.1

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6 EX.7 EX.8

EX.X

CORRIDOR

C101

S.Liu

CODE INFORMATION

G101

CODE LEGEND

Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:

Scale:

Drawn By:

Project Number:

Drawing Number:

SILVER PETRUCELLI + ASSOCIATES

203 230 9007

3190 WHITNEY AVENUE HAMDEN CT 06518

silverpetrucelli.com

311 STATE STREET NEW LONDON CT 06320

Project Phase:

25-106

06/12/2026

BID SET

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

As Indicated

X

2/28'-9"

3/55'-0"

A-3 (ASSEMBLY)

1986, 1999

14,685

NONE

IIB

X

13,655 SF

14,685

NONE

15. CODES TO WHICH THIS PROJECT WAS DESIGNED

13. ENTIRE BUILDING SPRINKLERED

14. THRESHOLD BUILDING CONDITIONS

CODE INFORMATION

4. ACTUAL BUILDING AREA (CSBC 502.1):

3. BUILDING HEIGHT (CSBC 504 & 506):

2. CONSTRUCTION TYPE (CSBC 602):

1. GROUP CLASSIFICATION (CSBC 302):

8. FIRE-RESISTANCE RATED REQUIREMENTS FOR BUILDING ELEMENTS

11. ACCESSIBLE BUILDING

9. OCCUPANCY LOAD - REFER TO LIFE & SAFETY PLANS FOR OCCUPANT

LOADS OF INDIVIDUAL ROOMS (CSBC 1004.1):

10. MODIFICATIONS

NoYes

DATE OF ORIGINAL CONSTRUCTION

EXISTING CONSTRUCTION

NEW CONSTRUCTION

1) BUILDING AREA (LOWER FLOOR LEVEL)

(STORIES ABOVE GRADE)

ACTUAL HEIGHT (STORY/FEET)

ALLOWABLE HEIGHT (STORY/FEET)

MINIMUM TYPE REQUIRED:

ACTUAL TYPE PROVIDED (EXISTING):

DATE OF ADDITIONS

sq.ft.

sq.ft.

(PROPOSED NEW OR ADDITION):

sq.ft.

DATE OF RENOVATIONS

Designated

Non Designated

(CSBC Table 601, See Code Plans for specific designations)

UPPER FLOOR

LOWER FLOOR

Not ApprovedApproved

TOTAL FLOOR

EXIT CAPACITY - (UPPER LEVEL)

EXIT CAPACITY

TOTAL EXIT CAPACITY FOR BUILDING

DESIGN TOTAL FOR BUILDING

M-XXX-XXX /(CSBC 506.2)

(Allowable Area Increase)

>30'

150.58 ft.

649 649

5. BUILDING AREA & MODIFICATIONS (CSBC 503 & 506):

Total Frontage (F)

Open Perimeter = Total Perimeter =

Total Perimeter (P)

N E ft.

W S ft.

If = (F/P - 0.25) W/30

(building perimeter which fronts on a public way or open space having 20 feet open min.)

(perimeter of the entire building)

Width of open space (W) =

N/A

12. MINIMUM PLUMBING FIXTURE COUNT (I.P.C. Chapter 4)

For each type of occupancy per entire facility

BUSINESS (B) Group occupancy:

TOTAL Occupancy Load (Use B) : (Design Load = 183)

2.14

2.83

2.83

Required

W/C Male

2.14

W/C Female

Lavs Male

Lavs Female

1.83

D/F

Service Sink

TOTAL REQUIRED AND PROVIDED QUANTITY OF PLUMBING FIXTURES:

3.16 (4)

Required

W/C Male

W/C Female

Lavs Male

Lavs Female

D/F

Service Sink

IIB

ASSEMBLY: A-3

Aa = [At + (NS x lf )]

At = 9,500

NS = 9,500

Aa = 9,500 + (9,500 x .75)

Aa = 16,625 sq. ft. (Max allowable area)

2021 IPC/2022 CT

Current

2010 ADA

2021 NFPA 1 & 101 / 2022 CT

ADA Standards for Accessible Design

Section 504

State Fire Prevention / Life Safety Code

State Energy Conservation Code w/ CT Amend.

State Plumbing Code w/ CT Amendments

State Mechanical Code w/ CT Amendments

State Electrical Code w/ CT Amendments

Accessible and Usable Bldgs w/ CT Amendments

2021 IMC / 2022 CT

2021 IECC / 2022 CT

2020 NFPA 70 / 2022 CT

2017 ICC A117.1 / 2022 CT

2021 IEBC/2022 CTState Existing Building Code w/ CT Amendments

2021 IFC/2022 CTState Fire Safety Code

State Building Code w/ CT Amendments 2021 IBC/2022 CT

7. CASE 2 - SEPARATED OCCUPANCIES (CSBC 508.4)

6. CASE 1 - NONSEPARATED OCCUPANCIES (CSBC 508.3)

LOWER FLOOR LEVEL

TOTAL FLOOR AREA 13,655 sq. ft B USE FLOOR AREA 6,493 sq. ft S-1 USE FLOOR ARE 6,701 sq.ft

REQUIRED FIRE-RESISTANCE RATED SEPARATION: NO SEPARATION REQUIREMENTS

(NOT USED)

NONE

NoYes X

19. HISTORIC BUILDING:

16. EXIT ACCESS:

17. EGRESS CAPACITY OF DOORS (CSBC 1005.3.2):

18. INTERIOR FINISHES (CSBC 803.13):

20. EGRESS-RELATED CODE INFORMATION:

EXIT ACCESS TRAVEL DISTANCE LIMITATIONS (CSBC 1017.2)

DOORS WITH STANDARD HOLLOW METAL FRAMES AND BUTT HINGES

SIZE CLEAR WIDTH MAX. OCC. LOAD (CAP = 0.2"/OCC)

(1) 3'-0" 33.125" 165 OCCUPANTS

(1) 3'-2" 35.125" 175 OCCUPANTS

(1) 3'-4" 37.125" 185 OCCUPANTS

(1) 3'-6" 39.125" 195 OCCUPANTS

(1) 3'-8" 41.125" 205 OCCUPANTS

(1) 3'-10" 43.125" 215 OCCUPANTS

(1) 4'-0" 45.125" 225 OCCUPANTS

(2) 3'-0" 67.125" 337 OCCUPANTS

(2) 3'-2" 71.125" 357 OCCUPANTS

(2) 3'-4" 75.125" 377 OCCUPANTS

(2) 3'-6" 79.125" 397 OCCUPANTS

(2) 3'-8" 83.125" 417 OCCUPANTS

(2) 3'-10" 87.125" 437 OCCUPANTS

(2) 4'-0" 91.125" 457 OCCUPANTS

FLOOR AREA ALLOWANCES PER OCCUPANT (CSBC 1004.5)

BUSINESS/OFFICE OCCUPANCY - 150 GROSS

EGRESS WIDTH PER OCCUPANT SERVED

STORAGE & MECHANICAL OCCUPANCY - 300 GROSS

COMMON PATH OF TRAVEL LIMITATIONS (CSBC 1006.2.1)

MINIMUM CORRIDOR WIDTH (CSBC 1020.3)

ALLOWABLE: PROVIDED:44" (B OCC.) > 44"

CORRIDOR DEAD END LIMITATION (CSBC 1020.5)

ALLOWABLE:

(2) 3'-7" 407 OCCUPANTS81.125"

(2) 3'-3" 73.125" 367 OCCUPANTS

DESIGN TOTAL FOR EACH FLOOR:

PROVIDED:

200' (S-1 OCC.)

< 200'

ALLOWABLE: PROVIDED:20' < 20'

NO

EGRESS - STAIRS = 0.3" PER PERSON (CSBC 1005.3.1)

EGRESS - CORRIDORS, RAMPS AND DOORS = 0.2" PER PERSON (CSBC 1005.3.2)

173.75 ft. ft. 150.58 ft.

ft. ft. ft. ft.

USE GROUP(S):

ACCESSORY USE AREAS (CSBC 508.2):

MIXED OCCUPANCIES (CSBC 508):

YES

NON-SEPARATED USES (CSBC 508.3): NO

SEPARATED USES (CSBC 508.4):

S-1 (STORAGE)

N/A

STORAGE: S-1

Aa = [At + (NS x lf )]

At = 17,500

NS = 17,500

Aa = 17,500 + (17,500 x .75)

Aa = 30,625 sq. ft. (Max allowable area)

As per Table 506.3.3, allowable increase = .75 Percentage of Open Perimeter (649 ft / 649 ft) x 100 = 100%

ALLOWABLE AREA ( Aa ) CALCULATION BY OCCUPANCY CLASSIFICATION:

N/A

14,414 SF

28,069 SF

1,664 Occ.

502 Occ.

1,162 Occ.

STORAGE (S-1) Group occupancy:

TOTAL Occupancy Load (Use S-1):_(Design Load = 32)

0.16

Required

W/C Male

W/C Female

Lavs Male

Lavs Female

0.03

D/F

Service Sink

0.16

0.16

0.16

3.31 (4)

2.41 (3)

2.41 (3)

1.94 (2)

Provided

ALLOWABLE: PROVIDED:

200' (B OCC.)

< 200'

GROUP

NONSPRINKLERED

B A S B

Interior exit stairways and ramps and exit passageways

Corridors and enclosure for exit access stairways and ramps

B B

C C

Rooms and enclosed spaces

Class Class Class

ASSEMBLY WITHOUT FIXED SEATS

CONCENTRATED (CHAIRS ONLY —NOT FIXED) - 7 NET

UNCONCENTRATED (TABLES AND CHAIRS) - 15 NET

22. THERMAL ENVELOPE:

21. FIRE TEST DESIGN INFORMATION:

STRUCTURAL FRAME:

EXISTING. REFER TO G102 FOR NEW 2-HOUR FIRE SEPARATION ASSEMBLY

FLOOR CONSTRUCTION (INCLUDING BEAMS):

ROOF CONSTRUCTION (INCLUDING BEAMS/JOISTS):

EXISTING

PARTITION CONSTRUCTION:

EXISTING, REFER TO A490 FOR NEW SPECIFIC UL-TESTED PARTITION ASSEMBLY

15,790

NONE

15,790

EXISTING CONSTRUCTION

NEW CONSTRUCTION

1) BUILDING AREA (UPPER FLOOR LEVEL)

sq.ft.

sq.ft.

sq.ft.TOTAL FLOOR

150.58 150.58

UPPER FLOOR LEVEL

TOTAL FLOOR AREA 14,414 sq. ft A USE FLOOR AREA 1,671 sq. ft B USE FLOOR AREA 12,325 sq. ft

REQUIRED FIRE-RESISTANCE RATED SEPARATION: 2HRS BETWEEN A USE AND B USE.

- (LOWER LEVEL)

NORTH

173.75 173.75173.75

- 1 existing bottle filler

The following fixtures are included in the "Provided" tabulation above:

Hr(s)

Structural frame: including columns, girders, trusses

2 Bearing walls:

Exterior (Table 602) Interior

3 Nonbearing walls & partitions Exterior (Table 602)

4 Nonbearing walls & partitions Interior

5 Floor Construction (including supporting beams & joists)

6 Roof Construction (including supporting beams & joists)

Hr(s) Hr(s)

Hr(s)

Hr(s)

Hr(s)

Hr(s)

- 5 existing single-occupant unisex accessible restrooms divided between genders

- 4 existing urinals

ALLOWABLE: PROVIDED:100' (B OCC.) < 100'

ALLOWABLE: PROVIDED:100' (S OCC.) <100'

EXISTING

EXISTING. REFER TO G102 FOR NEW 2-HOUR FIRE SEPARATION ASSEMBLY.

1 LOWER LEVEL USE GROUP OCCUPANCY PLAN

1/16"=1'-0"

2 UPPER LEVEL USE GROUP OCCUPANCY PLAN

1/16"=1'-0"

BUSINESS (B) GROUP

STORAGE (S-1) GROUP

ASSEMBLY (A-3) GROUP

B (BUSINESS)

BUSINESS: B

Aa = [At + (NS x lf )]

At = 23,000

NS = 23,000

Aa = 23,000 + (23,000 x .75)

Aa = 40,250 sq. ft. (Max allowable area)

A-3 A A C

ASSEMBLY (A-3) Group occupancy: (Conference Room)

TOTAL Occupancy Load (Use A) : (Design Load = 42)

0.11

0.32

0.17

Required

W/C Male

0.11

W/C Female

Lavs Male

Lavs Female

0.08

D/F

Service Sink

NOTE: ALL NEW SIGNAGE TO BE PROVIDED BY OWNER (N.I.C.)

23. ALTERATION (IEBC 603)

TOTAL WORK AREA: 13,478 sq.ft TOTAL BUILDING AREA: 30,475 sq.ft

PERCENTAGE: 44.2%

ALTERATION LEVEL: LEVEL 2

1 S.Liu06/22/2026Building Official Comments

WORK SPACE

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

214 OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

JAN.

SUPPLY CLOSET

H.C. TOILET

ELEC.

C201AMEN'S TOILET

WOMEN'S TOILET

CORRIDOR

C203

OFFICE

OFFICE

OFFICE

221OFFICE

OFFICE

223OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

OFFICE

OFFICE

OFFICE

231 OFFICE

OFFICE

VESTIBULE

LOBBY

235CONFERENCE ROOM

MEN'S TOILET

236WOMEN'S TOILET

KITCHEN

C205A

H.C. TOILET

STOR.

STOR.

234A

ELEC. CLOSET

C206A STOR.

C206B

STOR.

C206C

STOR.

C204A

15 SF

CORRIDOR

C207

CORRIDOR

C200

CONFERENCE ROOM

1671 SF

CORRIDOR

C201

CORRIDOR

C202

KITCHEN

C202B

CORRIDOR

C204

CORR.

C205

KITCHEN

C200A

CORRIDOR

C206

150 10

300 1 1

150 1

300 1

150 1

150 1143

150 1143 150 1

15 19

150 2

150 1

150 1

12 2

150 1

150 1

150 3141

150 1291 150 2368

150 3

150 2

150 1

150 1

15 25

150 2

150 1

150 2

150 3

150 2

15 26

150 4

STAIR

ST1.2

150 1

15 2

STAIR

ST2.2

ELEVATOR

EL1.2

23 24 25 27 28

2 1 3

20 21 24

43 44 46 49

79 79 119

15 1

TD 145'

TD 103'

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6

EX.7 EX.8

EX.X

OFFICE

150 1

MAXIMUM OCCUPANTS: 42*

* OWNER TO PROVIDE MAXIMUM OCCUPANCY SIGN OF 42 OCC.

CORRIDOR

C100

IT STORAGE

STORAGE

SUMP PUMP

CONFIDENTIAL STORAGE

SUMP PUMP

STORAGE

105A

SUMP PUMP

105B

SCIENCE KIT STORAGE

H.C. TOILET

WELLNESS

H.C. TOILET

CORRIDOR

C102

STORAGE

FOR PUPIL SERV.

TIS

DATA TEAM

OFFICE

OFFICE

112OFFICE

OFFICE

BREAKOUT AREA

OFFICE

OFFICE

OFFICE

118 OFFICE

OFFICE

VEST.

ELECTRICAL

STORAGE

SAFE ROOM

SAFE ROOM

STORAGE

FOR BUSINESS

STORAGE

FOR BUSINESS

STORAGE

FOR BUSINESS

WORK SPACE

DATA

MEN

VEST.

ELEC.

C100A

ELEC.

CLOSET

C104A

ELEV. MACH.

C104B

STOR.

C106A

WOMEN

133A

OFFICE

CORRIDOR

C103

STOR. CLOSET

C102A

CORR.

C104

KITCHEN

115A

CORRIDOR

C105

CORRIDOR

C106

CORRIDOR

C107

150 1

150 2

150 1

150 2

300 1

300 1

300 1

165 113

300 1

300 1

300 1

300 1

300 11

300 1259

150 1

150 1

150 1

150 1

150 1

15 27

15 3

150 2 2

150 1

150 3

300 5

300 1

300 3

300 1

300 6

300 1

300 1

STAIR

ST1.1

STAIR

ST2.1

ELEVATOR

EL1.1

300 3

111111

3456911

300 1 31

300 1

2 4

TD

1'

TD

TD 112'

TD

TD 64'

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6 EX.7 EX.8

EX.X

CORRIDOR

C101

S.Liu

CODE PLAN

G102

(60.66')

60.66'

MAX. ALLOWABLE EGRESS OCC. OF DOOR

ACTUAL EGRESS OCC. OF DOOR

CODE LEGEND

840 SF

TD 145'

DIRECTION OF TRAVEL W/ ACCUMULATED OCC. LOAD

EXIT CAPACITY

ROOM NUMBER

MAXIMUM TRAVEL DISTANCE FROM FURTHEST POINT

ROOM OCCUPANCY LOAD

1 HOUR RATED FIRE BARRIER

COMMON PATH OF TRAVEL

AREA IN SF

OCC. LOAD FACTOR

C216

198'

2 UPPER LEVEL CODE PLAN

3/32"=1'-0"

Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:

Scale:

Drawn By:

Project Number:

Drawing Number:

SILVER PETRUCELLI + ASSOCIATES

203 230 9007

3190 WHITNEY AVENUE HAMDEN CT 06518

silverpetrucelli.com

311 STATE STREET NEW LONDON CT 06320

Project Phase:

25-106

06/12/2026

BID SET

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

As Indicated

DIMENSION OF NON-OPEN PERIMETER ALONG ENTIRE

LONGITUDINAL FACE

DIMENSION OF OPEN PERIMETER ALONG ENTIRE

LONGITUDINAL FACE

1 LOWER LEVEL CODE PLAN

3/32"=1'-0"

+/-173' - 9"

NORTH

-1

'-7

+/-173'-83 8"

-1

'-7

2 HOUR RATED FIRE BARRIER

AREA TO BE PROVIDED WITH CONT. 2-HOUR

FIRE-RATED SEPARATION. APPLY FIRE PROOFING TO

EXIST. STRUCTURAL STEEL MEMBERS AS REQUIRED,

INCLUDING BEAMS, JOISTS, COLUMNS, DECKING, ETC.

VERIFY COVERAGE AND THICKNESS IN FIELD.

STORAGE

X100

SUMP PUMP

X101

STORAGE

X104

SUMP PUMP

X105

H.C. TOILET

X107

TOILET

X109

H.C. TOILET

X108

CORRIDOR

X106

OFFICE

X111

OFFICE

X112

OFFICE

X113

OFFICE

X114

OFFICE

X115

OFFICE

X116

BREAKOUT AREA

X117

OFFICE

X120

OFFICE

X121

OFFICE

X123

OFFICE

X124

VEST.

X125

ELECTRICAL

X126

STORAGE

X127

STORAGE

X128

STORAGE

X129

STORAGE

X131

STORAGE

X132

STORAGE

X133

WORK SPACE

X135

DATA

X134

MEN

X137

VEST.

X138

ELEC.

X100A

ELEC. CLOSET

X122A

ELE.

MACH.

X122B

JAN.

X136A

WOMEN

X138A

CORRIDOR

X110

CORR.

X118 CORRIDOR

X130CORRIDOR

X136

STORAGE

X110A

KITCHEN

X117A

STAIR

XST2.1

STAIR

XST1.1

ELEVATOR

XEL1.1

OFFICE

X119

CORRIDOR

X122

STORAGE

X102

SUMP PUMP

X103

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6 EX.7 EX.8

EX.X

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6 EX.7 EX.8

EX.X

DEMOLITION GENERAL NOTES

1. READ ALL GENERAL NOTES ON DRAWING G100.

2. PROPERLY DISPOSE OF ALL ITEMS IDENTIFIED IN DEMOLITION NOTES BELOW, UNLESS

OTHERWISE NOTED AS "SALVAGE".

3. DEMOLITION TAGS WITHOUT LEADERS & LOCATED BENEATH EXISTING ROOM NAMES SHALL

APPLY IN ENTIRETY TO THE ROOM IN WHICH THEY ARE LOCATED.

4. COORDINATE ARCHITECTURAL DEMOLITION WORK WITH ALL OTHER TRADES, INCLUDING

HAZARDOUS MATERIAL ABATEMENT DRAWINGS.

5. WHERE INCONSISTENCIES OCCUR, NOTIFY THE DESIGN TEAM & ASSUME THE GREATER VALUE

FOR BIDDING PURPOSES.

6. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS & DIMENSIONS.

7. SAW CUT/CORE EXISTING ELEVATED CONCRETE SLAB & DECK AT ALL AREAS AS NECESSARY

FOR NEW PIPING, CONDUIT, ETC. COORDINATE w/M/E/P/FP DRAWINGS.

8. ITEMS IDENTIFIED WITH DASHED LINES, AS SHOWN ABOVE, BUT WITHOUT TAGS SHALL BE

ASSUMED AS ITEMS TO BE DEMOLISHED.

9. PROVIDE NEW OPENINGS IN EXISTING WALLS AS NECESSARY FOR ALL NEW PENETRATIONS

BY DUCT, PIPE, CONDUIT, ETC.

10. NOT ALL DEMOLITION NOTES ARE PRESENT ON EVERY DEMOLITION SHEET.

11. THIS DRAWING IS INTENDED TO SHOW THE GENERAL LAYOUT OF EXISTING CONSTRUCTION

TO BE REMOVED. IT IS NOT A DETAILED REPRESENTATION OF THE SPECIFIC ITEMS FOR

REMOVAL, AND SHOULD NOT BE A SUBSTITUTE FOR THE CONTRACTOR'S OWN

DETERMINATION OF THE EXTENT OF REMOVAL INVOLVED THROUGH FIELD INSPECTIONS. IN

GENERAL, DEMOLITION IS TO INCLUDE THE REMOVAL OF ALL EXISTING CONSTRUCTION

NECESSARY FOR THE COMPLETION OF THE CONTRACT.

DEMOLITION LEGEND

EXISTING WALLS TO REMAIN

DASHED LINES INDICATE REMOVALS, SEE DEMOLITION NOTES ON

ARCHITECTURAL AS WELL AS ALL M/E/P/FP DRAWINGS.

DEMOLITION NOTESD01

DEMOLITION NOTES

1. REMOVE & DISPOSE OF EXISTING METAL STUD PARTITION WALL/SOFFIT.

2. REMOVE & DISPOSE OF EXISTING METAL STUD PARTITION WALL AS REQUIRED TO

ACCOMMODATE NEW DOOR. REMOVE EXISTING GYPSUM BOARD, WALL COVE BASE, & METAL

STUDS WITHIN THE EXTENT OF THE DOOR OPENING.

3. REMOVE & DISPOSE OF EXISTING DOOR, INCLUDING HOLLOW METAL FRAME, ANY ATTACHED

VIEWING PANELS/SIDELIGHTS, & ASSOCIATED HARDWARE.

4. REMOVE EXISTING P.LAM COUNTERTOP, METAL SINK & FAUCET. CAP ALL PLUMBING LINES AS

REQUIRED TO RECEIVE NEW SINK. SEE PLUMBING DWGS.

5. REMOVE EXISTING RUBBER WALL BASE AS REQUIRED TO RECEIVE NEW METAL STUD

PARTITION WALL.

6. REMOVE EXISTING 2X2 CEILING GRIDS, LIGHTS, DIFFUSERS, & OTHER CEILING MOUNTED

FIXTURES IN THE ENTIRE ROOM. COORDINATE WITH MECHANICAL TO RELOCATE/REINSTALL

DIFFUSERS & GRILLES. COORDINATE WITH ELECTRICAL TO RELOCATE/REINSTALL LIGHTS.

7. REMOVE & RELOCATE EXISTING 2X2 LIGHTS. SEE ELECTRICAL DWGS.

8. REMOVE & RELOCATE EXISTING DIFFUSERS/GRILLES. SEE MECHANICAL DWGS.

9. REMOVE ALL EXISTING WINDOW FILM FROM EXISTING DOOR/WINDOW GLAZING.

10. REMOVE ALL EXISTING DIMENSIONAL SIGNAGE ON COLUMNS. WHERE THIS OCCURS, PATCH &

REFINISH FASTENER HOLES TO MATCH EXISTING FINISH.

11. REMOVE EXISTING P.LAM BASE COUNTER.

12. REMOVE GYPSUM BOARD AS REQUIRED TO INSTALL NEW ELEC. DEVICES. REFER TO ELEC.

DWGS.

13. REMOVE EXISTING WATER CLOSET AND ASSOCIATED HARDWARE. CAP AND SEAL ALL PIPING

AS REQUIRED. SEE PLUMBING DWGS.

14. REMOVE EXISTING GYPSUM BOARD FINISH TO RECEIVE FIRE PROOFING.

15. REMOVE AND REINSTALL CEILING GRID AS REQUIRED TO COORDINATE AND ALLOW FOR NEW

HVAC WORK. COORDINATE WITH MECHANICAL DRAWINGS.

16. REMOVE AND REINSTALL CEILING GRID AS REQUIRED TO INSTALL NEW GYPSUM BOARD AT

INSIDE FACE OF EXTERIOR WALL. REFER TO CONSTRUCTION NOTE C10.

17. EXISTING CEILING SYSTEM TO REMAIN.

D01

LOWER LEVEL DEMOLITION PLAN

A010 Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:

Scale:

Drawn By:

Project Number:

Drawing Number:

SILVER PETRUCELLI + ASSOCIATES

203 230 9007

3190 WHITNEY AVENUE HAMDEN CT 06518

silverpetrucelli.com

311 STATE STREET NEW LONDON CT 06320

Project Phase:

25-106

06/12/2026

BID SET

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

As Indicated

1 LOWER LEVEL DEMOLITION PLAN

1/8"=1'-0"

D02

D03

D03

D03

D01

D04

D04

3'-4" +/-3'-2"

D02

-7

'-0

3'- 4"

3'- 6"

D05

D05

D03D03

D03

S.Liu

-1

1'- 1"

D13

11"

D14 D14

D14

D14

D14

D14

D14

D03

EXISTING DEPRESSED

SLAB WITH RAISED

FLOOR WITHIN EXTENT

OF PHANTOM LINE.

PHANTOM LINE INDICATE EXISTING DEPRESSED SLAB

WITH RAISED FLOOR.

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6

EX.7 EX.8

EX.X

ENTRY

X200

OFFICE

X202

OFFICE

X217

OFFICE

X216

OFFICE

X215

OFFICE

X214

OFFICE

X213

OFFICE

X212

OFFICE

X211

JAN.

X206

SUPPLY CLOSET

X205

H.C. TOILET

X204

ELEC.

X203A

MEN'S TOILET

X208

WOMEN'S TOILET

X207

CORRIDOR

X209

OFFICE

X220

OFFICE

X221

OFFICE

X222

OFFICE

X223

OFFICE

X224

OFFICE

X225

OFFICE

X227

OFFICE

X228

OFFICE

X229

CONFERENCE ROOM

X230

OFFICE

X232

OFFICE

X233

OFFICE

X234

OFFICE

X235

OFFICE

X236

VESTIBULE

X238

LOBBY

X237CONFERENCE ROOM

X239

MEN'S TOILET

X240

WOMEN'S TOILET

X241

KITCHEN

X226A

H.C. TOILET

X242

STOR.

X237B

STOR.

X237A

ELEC.

X231A

STOR.

X231B

STORAGE

X231C

STOR.

X219A

15 SF

CORRIDOR

X219

CORRIDOR

X201

CORRIDOR

X210

KITCHEN

X210A

CORRIDOR

X203

CORRIDOR

X226

CORRIDOR

X231

CORRIDOR

X238

KITCHEN

X201A

STAIR

XST2.2

STAIR

XST1.2

ELEVATOR

XEL1.2

OFFICE

X218

EX.LADDER

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6

EX.7 EX.8

EX.X

DEMOLITION GENERAL NOTES

1. READ ALL GENERAL NOTES ON DRAWING G100.

2. PROPERLY DISPOSE OF ALL ITEMS IDENTIFIED IN DEMOLITION NOTES BELOW, UNLESS

OTHERWISE NOTED AS "SALVAGE".

3. DEMOLITION TAGS WITHOUT LEADERS & LOCATED BENEATH EXISTING ROOM NAMES SHALL

APPLY IN ENTIRETY TO THE ROOM IN WHICH THEY ARE LOCATED.

4. COORDINATE ARCHITECTURAL DEMOLITION WORK WITH ALL OTHER TRADES, INCLUDING

HAZARDOUS MATERIAL ABATEMENT DRAWINGS.

5. WHERE INCONSISTENCIES OCCUR, NOTIFY THE DESIGN TEAM & ASSUME THE GREATER VALUE

FOR BIDDING PURPOSES.

6. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS & DIMENSIONS.

7. SAW CUT/CORE EXISTING ELEVATED CONCRETE SLAB & DECK AT ALL AREAS AS NECESSARY

FOR NEW PIPING, CONDUIT, ETC. COORDINATE w/M/E/P/FP DRAWINGS.

8. ITEMS IDENTIFIED WITH DASHED LINES, AS SHOWN ABOVE, BUT WITHOUT TAGS SHALL BE

ASSUMED AS ITEMS TO BE DEMOLISHED.

9. PROVIDE NEW OPENINGS IN EXISTING WALLS AS NECESSARY FOR ALL NEW PENETRATIONS

BY DUCT, PIPE, CONDUIT, ETC.

10. NOT ALL DEMOLITION NOTES ARE PRESENT ON EVERY DEMOLITION SHEET.

11. THIS DRAWING IS INTENDED TO SHOW THE GENERAL LAYOUT OF EXISTING CONSTRUCTION

TO BE REMOVED. IT IS NOT A DETAILED REPRESENTATION OF THE SPECIFIC ITEMS FOR

REMOVAL, AND SHOULD NOT BE A SUBSTITUTE FOR THE CONTRACTOR'S OWN

DETERMINATION OF THE EXTENT OF REMOVAL INVOLVED THROUGH FIELD INSPECTIONS. IN

GENERAL, DEMOLITION IS TO INCLUDE THE REMOVAL OF ALL EXISTING CONSTRUCTION

NECESSARY FOR THE COMPLETION OF THE CONTRACT.

DEMOLITION LEGEND

EXISTING WALLS TO REMAIN

DASHED LINES INDICATE REMOVALS, SEE DEMOLITION NOTES ON

ARCHITECTURAL AS WELL AS ALL M/E/P/FP DRAWINGS.

DEMOLITION NOTESD01

DEMOLITION NOTES

1. REMOVE & DISPOSE OF EXISTING METAL STUD PARTITION WALL/SOFFIT.

2. REMOVE & DISPOSE OF EXISTING METAL STUD PARTITION WALL AS REQUIRED TO

ACCOMMODATE NEW DOOR. REMOVE EXISTING GYPSUM BOARD, WALL COVE BASE, & METAL

STUDS WITHIN THE EXTENT OF THE DOOR OPENING.

3. REMOVE & DISPOSE OF EXISTING DOOR, INCLUDING HOLLOW METAL FRAME, ANY ATTACHED

VIEWING PANELS/SIDELIGHTS, & ASSOCIATED HARDWARE.

4. REMOVE EXISTING P.LAM COUNTERTOP, METAL SINK & FAUCET. CAP ALL PLUMBING LINES AS

REQUIRED TO RECEIVE NEW SINK. SEE PLUMBING DWGS.

5. REMOVE EXISTING RUBBER WALL BASE AS REQUIRED TO RECEIVE NEW METAL STUD

PARTITION WALL.

6. REMOVE EXISTING 2X2 CEILING GRIDS, LIGHTS, DIFFUSERS, & OTHER CEILING MOUNTED

FIXTURES IN THE ENTIRE ROOM. COORDINATE WITH MECHANICAL TO RELOCATE/REINSTALL

DIFFUSERS & GRILLES. COORDINATE WITH ELECTRICAL TO RELOCATE/REINSTALL LIGHTS.

7. REMOVE & RELOCATE EXISTING 2X2 LIGHTS. SEE ELECTRICAL DWGS.

8. REMOVE & RELOCATE EXISTING DIFFUSERS/GRILLES. SEE MECHANICAL DWGS.

9. REMOVE ALL EXISTING WINDOW FILM FROM EXISTING DOOR/WINDOW GLAZING.

10. REMOVE ALL EXISTING DIMENSIONAL SIGNAGE ON COLUMNS. WHERE THIS OCCURS, PATCH &

REFINISH FASTENER HOLES TO MATCH EXISTING FINISH.

11. REMOVE EXISTING P.LAM BASE COUNTER.

12. REMOVE GYPSUM BOARD AS REQUIRED TO INSTALL NEW ELEC. DEVICES. REFER TO ELEC.

DWGS.

13. REMOVE EXISTING WATER CLOSET AND ASSOCIATED HARDWARE. CAP AND SEAL ALL PIPING

AS REQUIRED. SEE PLUMBING DWGS.

14. REMOVE EXISTING GYPSUM BOARD FINISH TO RECEIVE FIRE PROOFING.

15. REMOVE AND REINSTALL CEILING GRID AS REQUIRED TO COORDINATE AND ALLOW FOR NEW

HVAC WORK. COORDINATE WITH MECHANICAL DRAWINGS.

16. REMOVE AND REINSTALL CEILING GRID AS REQUIRED TO INSTALL NEW GYPSUM BOARD AT

INSIDE FACE OF EXTERIOR WALL. REFER TO CONSTRUCTION NOTE C10.

17. EXISTING CEILING SYSTEM TO REMAIN.

D01

UPPER LEVEL DEMOLITION PLAN

A011 Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:

Scale:

Drawn By:

Project Number:

Drawing Number:

SILVER PETRUCELLI + ASSOCIATES

203 230 9007

3190 WHITNEY AVENUE HAMDEN CT 06518

silverpetrucelli.com

311 STATE STREET NEW LONDON CT 06320

Project Phase:

25-106

06/12/2026

BID SET

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

As Indicated

1 UPPER LEVEL DEMOLITION PLAN

1/8"=1'-0"

D02

D03D03

D02

D03

D03

D04

D02

D02 D02

-1

0'- 1"

3'- 4"

1'- 51 2"

3'- 4"

-1

1'- 21 2"

4"

-1

0'- 2"

3'- 4"

-1

0'- 2"

3'- 4"

+/-7'-61 2" 3'-4" 4"

S.Liu

D04

D12

D12

D12

D12

D12

D12

D10

D09

D09

D09

D09

2'- 81 2"

2'- 81 2"

S

STORAGE

X100

SUMP PUMP

X101

STORAGE

X104

SUMP PUMP

X105

H.C. TOILET

X107

TOILET

X109

H.C. TOILET

X108

CORRIDOR

X106

OFFICE

X111

OFFICE

X112

OFFICE

X113

OFFICE

X114

OFFICE

X115

OFFICE

X116

BREAKOUT AREA

X117

OFFICE

X120

OFFICE

X121

OFFICE

X123

OFFICE

X124

VEST.

X125

ELECTRICAL

X126

STORAGE

X127

STORAGE

X128

STORAGE

X129

STORAGE

X131

STORAGE

X132

STORAGE

X133

WORK SPACE

X135

DATA

X134

MEN

X137

VEST.

X138

ELEC.

X100A

ELEC. CLOSET

X122A

ELE.

MACH.

X122B

JAN.

X136A

WOMEN

X138A

CORRIDOR

X110

CORR.

X118 CORRIDOR

X130CORRIDOR

X136

STORAGE

X110A

KITCHEN

X117A

STAIR

XST2.1

STAIR

XST1.1

ELEVATOR

XEL1.1

OFFICE

X119

CORRIDOR

X122

STORAGE

X102

SUMP PUMP

X103

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6 EX.7 EX.8

EX.X

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6 EX.7 EX.8

EX.X

DEMOLITION GENERAL NOTES

1. READ ALL GENERAL NOTES ON DRAWING G100.

2. PROPERLY DISPOSE OF ALL ITEMS IDENTIFIED IN DEMOLITION NOTES BELOW, UNLESS

OTHERWISE NOTED AS "SALVAGE".

3. DEMOLITION TAGS WITHOUT LEADERS & LOCATED BENEATH EXISTING ROOM NAMES SHALL

APPLY IN ENTIRETY TO THE ROOM IN WHICH THEY ARE LOCATED.

4. COORDINATE ARCHITECTURAL DEMOLITION WORK WITH ALL OTHER TRADES, INCLUDING

HAZARDOUS MATERIAL ABATEMENT DRAWINGS.

5. WHERE INCONSISTENCIES OCCUR, NOTIFY THE DESIGN TEAM & ASSUME THE GREATER VALUE

FOR BIDDING PURPOSES.

6. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS & DIMENSIONS.

7. SAW CUT/CORE EXISTING ELEVATED CONCRETE SLAB & DECK AT ALL AREAS AS NECESSARY

FOR NEW PIPING, CONDUIT, ETC. COORDINATE w/M/E/P/FP DRAWINGS.

8. ITEMS IDENTIFIED WITH DASHED LINES, AS SHOWN ABOVE, BUT WITHOUT TAGS SHALL BE

ASSUMED AS ITEMS TO BE DEMOLISHED.

9. PROVIDE NEW OPENINGS IN EXISTING WALLS AS NECESSARY FOR ALL NEW PENETRATIONS

BY DUCT, PIPE, CONDUIT, ETC.

10. NOT ALL DEMOLITION NOTES ARE PRESENT ON EVERY DEMOLITION SHEET.

11. THIS DRAWING IS INTENDED TO SHOW THE GENERAL LAYOUT OF EXISTING CONSTRUCTION

TO BE REMOVED. IT IS NOT A DETAILED REPRESENTATION OF THE SPECIFIC ITEMS FOR

REMOVAL, AND SHOULD NOT BE A SUBSTITUTE FOR THE CONTRACTOR'S OWN

DETERMINATION OF THE EXTENT OF REMOVAL INVOLVED THROUGH FIELD INSPECTIONS. IN

GENERAL, DEMOLITION IS TO INCLUDE THE REMOVAL OF ALL EXISTING CONSTRUCTION

NECESSARY FOR THE COMPLETION OF THE CONTRACT.

DEMOLITION LEGEND

EXISTING WALLS TO REMAIN

DASHED LINES INDICATE REMOVALS, SEE DEMOLITION NOTES ON

ARCHITECTURAL AS WELL AS ALL M/E/P/FP DRAWINGS.

DEMOLITION NOTESD01

DEMOLITION NOTES

1. REMOVE & DISPOSE OF EXISTING METAL STUD PARTITION WALL/SOFFIT.

2. REMOVE & DISPOSE OF EXISTING METAL STUD PARTITION WALL AS REQUIRED TO

ACCOMMODATE NEW DOOR. REMOVE EXISTING GYPSUM BOARD, WALL COVE BASE, & METAL

STUDS WITHIN THE EXTENT OF THE DOOR OPENING.

3. REMOVE & DISPOSE OF EXISTING DOOR, INCLUDING HOLLOW METAL FRAME, ANY ATTACHED

VIEWING PANELS/SIDELIGHTS, & ASSOCIATED HARDWARE.

4. REMOVE EXISTING P.LAM COUNTERTOP, METAL SINK & FAUCET. CAP ALL PLUMBING LINES AS

REQUIRED TO RECEIVE NEW SINK. SEE PLUMBING DWGS.

5. REMOVE EXISTING RUBBER WALL BASE AS REQUIRED TO RECEIVE NEW METAL STUD

PARTITION WALL.

6. REMOVE EXISTING 2X2 CEILING GRIDS, LIGHTS, DIFFUSERS, & OTHER CEILING MOUNTED

FIXTURES IN THE ENTIRE ROOM. COORDINATE WITH MECHANICAL TO RELOCATE/REINSTALL

DIFFUSERS & GRILLES. COORDINATE WITH ELECTRICAL TO RELOCATE/REINSTALL LIGHTS.

7. REMOVE & RELOCATE EXISTING 2X2 LIGHTS. SEE ELECTRICAL DWGS.

8. REMOVE & RELOCATE EXISTING DIFFUSERS/GRILLES. SEE MECHANICAL DWGS.

9. REMOVE ALL EXISTING WINDOW FILM FROM EXISTING DOOR/WINDOW GLAZING.

10. REMOVE ALL EXISTING DIMENSIONAL SIGNAGE ON COLUMNS. WHERE THIS OCCURS, PATCH &

REFINISH FASTENER HOLES TO MATCH EXISTING FINISH.

11. REMOVE EXISTING P.LAM BASE COUNTER.

12. REMOVE GYPSUM BOARD AS REQUIRED TO INSTALL NEW ELEC. DEVICES. REFER TO ELEC.

DWGS.

13. REMOVE EXISTING WATER CLOSET AND ASSOCIATED HARDWARE. CAP AND SEAL ALL PIPING

AS REQUIRED. SEE PLUMBING DWGS.

14. REMOVE EXISTING GYPSUM BOARD FINISH TO RECEIVE FIRE PROOFING.

15. REMOVE AND REINSTALL CEILING GRID AS REQUIRED TO COORDINATE AND ALLOW FOR NEW

HVAC WORK. COORDINATE WITH MECHANICAL DRAWINGS.

16. REMOVE AND REINSTALL CEILING GRID AS REQUIRED TO INSTALL NEW GYPSUM BOARD AT

INSIDE FACE OF EXTERIOR WALL. REFER TO CONSTRUCTION NOTE C10.

17. EXISTING CEILING SYSTEM TO REMAIN.

D01

LOWER LEVEL DEMOLITION RCP

A020 Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:

Scale:

Drawn By:

Project Number:

Drawing Number:

SILVER PETRUCELLI + ASSOCIATES

203 230 9007

3190 WHITNEY AVENUE HAMDEN CT 06518

silverpetrucelli.com

311 STATE STREET NEW LONDON CT 06320

Project Phase:

25-106

06/12/2026

BID SET

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

As Indicated

1 LOWER LEVEL DEMOLITION RCP

1/8"=1'-0"

D01

S.Liu

D07

D06

D06

D01

D08

D07

D08 D07

D08

D07

D08

D16

D16

D16

D16

D16

D16

D16

D16

D15

D15 D15

D15

D06

D08

D06

D06

D06

D06

D02

D17 D17 D17

D17

D17

D17 D17

D17

D17

D17 D17

D17

D17

D17

D17

D17

D17 D17 D17 D17

D17

D17

D17

D17

D15

D17

D17

D17

D17 D17D02

D17 D17

D17

D17 D17

D17

D17

D17

D17

D17D17

D17

D17

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6

EX.7 EX.8

EX.X

ENTRY

X200

OFFICE

X202

OFFICE

X217

OFFICE

X216

OFFICE

X215

OFFICE

X214

OFFICE

X213

OFFICE

X212

OFFICE

X211

JAN.

X206

SUPPLY CLOSET

X205

H.C. TOILET

X204

ELEC.

X203A

MEN'S TOILET

X208

WOMEN'S TOILET

X207

CORRIDOR

X209

OFFICE

X220

OFFICE

X221

OFFICE

X222

OFFICE

X223

OFFICE

X224

OFFICE

X225

OFFICE

X227

OFFICE

X228

OFFICE

X229

CONFERENCE ROOM

X230

OFFICE

X232

OFFICE

X233

OFFICE

X234

OFFICE

X235

OFFICE

X236

VESTIBULE

X238

LOBBY

X237CONFERENCE ROOM

X239

MEN'S TOILET

X240

WOMEN'S TOILET

X241

KITCHEN

X226A

H.C. TOILET

X242

STOR.

X237B

STOR.

X237A

ELEC.

X231A

STOR.

X231B

STORAGE

X231C

STOR.

X219A

15 SF

CORRIDOR

X219

CORRIDOR

X201

CORRIDOR

X210

KITCHEN

X210A

CORRIDOR

X203

CORRIDOR

X226

CORRIDOR

X231

CORRIDOR

X238

KITCHEN

X201A

STAIR

XST2.2

STAIR

XST1.2

ELEVATOR

XEL1.2

OFFICE

X218

EX.LADDER

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6

EX.7 EX.8

EX.X

DEMOLITION GENERAL NOTES

1. READ ALL GENERAL NOTES ON DRAWING G100.

2. PROPERLY DISPOSE OF ALL ITEMS IDENTIFIED IN DEMOLITION NOTES BELOW, UNLESS

OTHERWISE NOTED AS "SALVAGE".

3. DEMOLITION TAGS WITHOUT LEADERS & LOCATED BENEATH EXISTING ROOM NAMES SHALL

APPLY IN ENTIRETY TO THE ROOM IN WHICH THEY ARE LOCATED.

4. COORDINATE ARCHITECTURAL DEMOLITION WORK WITH ALL OTHER TRADES, INCLUDING

HAZARDOUS MATERIAL ABATEMENT DRAWINGS.

5. WHERE INCONSISTENCIES OCCUR, NOTIFY THE DESIGN TEAM & ASSUME THE GREATER VALUE

FOR BIDDING PURPOSES.

6. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS & DIMENSIONS.

7. SAW CUT/CORE EXISTING ELEVATED CONCRETE SLAB & DECK AT ALL AREAS AS NECESSARY

FOR NEW PIPING, CONDUIT, ETC. COORDINATE w/M/E/P/FP DRAWINGS.

8. ITEMS IDENTIFIED WITH DASHED LINES, AS SHOWN ABOVE, BUT WITHOUT TAGS SHALL BE

ASSUMED AS ITEMS TO BE DEMOLISHED.

9. PROVIDE NEW OPENINGS IN EXISTING WALLS AS NECESSARY FOR ALL NEW PENETRATIONS

BY DUCT, PIPE, CONDUIT, ETC.

10. NOT ALL DEMOLITION NOTES ARE PRESENT ON EVERY DEMOLITION SHEET.

11. THIS DRAWING IS INTENDED TO SHOW THE GENERAL LAYOUT OF EXISTING CONSTRUCTION

TO BE REMOVED. IT IS NOT A DETAILED REPRESENTATION OF THE SPECIFIC ITEMS FOR

REMOVAL, AND SHOULD NOT BE A SUBSTITUTE FOR THE CONTRACTOR'S OWN

DETERMINATION OF THE EXTENT OF REMOVAL INVOLVED THROUGH FIELD INSPECTIONS. IN

GENERAL, DEMOLITION IS TO INCLUDE THE REMOVAL OF ALL EXISTING CONSTRUCTION

NECESSARY FOR THE COMPLETION OF THE CONTRACT.

DEMOLITION LEGEND

EXISTING WALLS TO REMAIN

DASHED LINES INDICATE REMOVALS, SEE DEMOLITION NOTES ON

ARCHITECTURAL AS WELL AS ALL M/E/P/FP DRAWINGS.

DEMOLITION NOTESD01

DEMOLITION NOTES

1. REMOVE & DISPOSE OF EXISTING METAL STUD PARTITION WALL/SOFFIT.

2. REMOVE & DISPOSE OF EXISTING METAL STUD PARTITION WALL AS REQUIRED TO

ACCOMMODATE NEW DOOR. REMOVE EXISTING GYPSUM BOARD, WALL COVE BASE, & METAL

STUDS WITHIN THE EXTENT OF THE DOOR OPENING.

3. REMOVE & DISPOSE OF EXISTING DOOR, INCLUDING HOLLOW METAL FRAME, ANY ATTACHED

VIEWING PANELS/SIDELIGHTS, & ASSOCIATED HARDWARE.

4. REMOVE EXISTING P.LAM COUNTERTOP, METAL SINK & FAUCET. CAP ALL PLUMBING LINES AS

REQUIRED TO RECEIVE NEW SINK. SEE PLUMBING DWGS.

5. REMOVE EXISTING RUBBER WALL BASE AS REQUIRED TO RECEIVE NEW METAL STUD

PARTITION WALL.

6. REMOVE EXISTING 2X2 CEILING GRIDS, LIGHTS, DIFFUSERS, & OTHER CEILING MOUNTED

FIXTURES IN THE ENTIRE ROOM. COORDINATE WITH MECHANICAL TO RELOCATE/REINSTALL

DIFFUSERS & GRILLES. COORDINATE WITH ELECTRICAL TO RELOCATE/REINSTALL LIGHTS.

7. REMOVE & RELOCATE EXISTING 2X2 LIGHTS. SEE ELECTRICAL DWGS.

8. REMOVE & RELOCATE EXISTING DIFFUSERS/GRILLES. SEE MECHANICAL DWGS.

9. REMOVE ALL EXISTING WINDOW FILM FROM EXISTING DOOR/WINDOW GLAZING.

10. REMOVE ALL EXISTING DIMENSIONAL SIGNAGE ON COLUMNS. WHERE THIS OCCURS, PATCH &

REFINISH FASTENER HOLES TO MATCH EXISTING FINISH.

11. REMOVE EXISTING P.LAM BASE COUNTER.

12. REMOVE GYPSUM BOARD AS REQUIRED TO INSTALL NEW ELEC. DEVICES. REFER TO ELEC.

DWGS.

13. REMOVE EXISTING WATER CLOSET AND ASSOCIATED HARDWARE. CAP AND SEAL ALL PIPING

AS REQUIRED. SEE PLUMBING DWGS.

14. REMOVE EXISTING GYPSUM BOARD FINISH TO RECEIVE FIRE PROOFING.

15. REMOVE AND REINSTALL CEILING GRID AS REQUIRED TO COORDINATE AND ALLOW FOR NEW

HVAC WORK. COORDINATE WITH MECHANICAL DRAWINGS.

16. REMOVE AND REINSTALL CEILING GRID AS REQUIRED TO INSTALL NEW GYPSUM BOARD AT

INSIDE FACE OF EXTERIOR WALL. REFER TO CONSTRUCTION NOTE C10.

17. EXISTING CEILING SYSTEM TO REMAIN.

D01

UPPER LEVEL DEMOLITION RCP

A021 Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:

Scale:

Drawn By:

Project Number:

Drawing Number:

SILVER PETRUCELLI + ASSOCIATES

203 230 9007

3190 WHITNEY AVENUE HAMDEN CT 06518

silverpetrucelli.com

311 STATE STREET NEW LONDON CT 06320

Project Phase:

25-106

06/12/2026

BID SET

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

As Indicated

1 UPPER LEVEL DEMOLITION RCP

1/8"=1'-0"

EX. SKYLIGHT

EX. SKYLIGHT

S.Liu

D07

D07

D08

D07 D07

D07

D08

D16

D16

D16 D16

D15

D15

D15

D08

D06

D15

D08

D15

D17 D17 D17

D17

D17

D17

D17

D17 D17 D17

D17 D17

D17

D17

D17 D17 D17 D17

D17

D17 D17 D17

D17

D17

D17

D17D17

D17 D17

D17 D17

D17

D17

D17

D17 D17 D17 D17

D17

D17

D17

D17

D17 D17D17

D17

D17D17

D17

D17

D17

D17

D17

D16

D16

D16

D16

D16

D16

D15

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6 EX.7 EX.8

EX.X

CORRIDOR

C100

IT STORAGE

STORAGE

SUMP PUMP

STORAGE

105A

SUMP PUMP

105B

SCIENCE KIT STORAGE

H.C. TOILET

WELLNESS

H.C. TOILET

CORRIDOR

C102

COPY ROOM

TIS

DATA TEAM

OFFICE

OFFICE

OFFICE

OFFICE

BREAKOUT AREA

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

VEST.

ELECTRICAL

STORAGE

SAFE ROOM

SAFE ROOM

STORAGE

FOR BUSINESS

STORAGE

FOR BUSINESS

STORAGE

FOR BUSINESS

WORK SPACE

DATA

MEN

VEST.

ELEC.

C100A

ELEC. CLOSET

C105A

ELE.

MACH.

C105B

JAN.

C107A

WOMEN

133A

CORRIDOR

C103

CORR.

C104 CORRIDOR

C106CORRIDOR

C107

STORAGE

C103A

KITCHEN

115A

CORRIDOR

C101

STAIR

ST2.1

STAIR

ST1.1

ELEVATOR

EL1.1

OFFICE

CORRIDOR

C105

CONFIDENTIAL STORAGE

SUMP PUMP

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6 EX.7 EX.8

EX.X

PLAN SYMBOL LEGEND

EXISTING WALLS TO REMAIN

CONSTRUCTION NOTES - SEE DWG. A110

### DOOR TAG

Cxx

EXISTING DOORS TO REMAIN

NEW WALL

NEW DOOR, ALL NEW DOORS AND METAL FRAMES

N.I.C. SEE GENERAL NOTE #8

ROOM TAG

1 WALL TAG

A110

DETAIL BOX

DETAIL BUBBLE TAG

GENERAL NOTES

1. READ ALL GENERAL NOTES ON DRAWING G100.

2. INTERIOR PARTITION DIMENSIONS ARE FROM OUTSIDE FACE OF GWB,

MASONRY, OR CONCRETE.

3. CONTRACTORS SHALL FIELD VERIFY ALL CONDITIONS & DIMENSIONS.

4. PATCH TO MATCH ALL EXISTING WALLS, CEILINGS, & SURFACES TO REMAIN

THAT ARE AFFECTED BY THE NEW WORK.

5. ALL NEW WALL & PARTITION ASSEMBLIES SHALL EXTEND TO UNDERSIDE OF

DECK UNLESS OTHERWISE NOTED.

6. WHERE THE WORD "ALIGN" IS INDICATED IT SHALL MEAN TO ALIGN BOTH SIDES

OF WALL.

7. SEE M/E/P DRAWINGS TO COORDINATE NEW OPENINGS REQUIRED IN WALLS

TO ACCOMMODATE NEW DUCTS, PIPES, & CONDUITS. FRAME AND SEAL

OPENINGS AS REQUIRED.

OFFICE

CONSTRUCTION NOTES

1. PATCH & REPAIR AT PARTITION WALL TO MATCH EXISTING. PROVIDE SMOOTH

SURFACE TO RECEIVE NEW PAINT.

2. NEW 2X2 ACT TILES TO BE PROVIDED BY OWNER AND INSTALLED BY

CONTRACTOR IN THE EXISTING CEILING GRIDS.

3. NEW 2X2 ACT TILES TO BE PROVIDED BY OWNER AND INSTALLED BY

CONTRACTOR IN NEW CEILING GRIDS. CONTRACTOR TO PROVIDE CEILING

GRIDS, INCLUDING ASSOCIATED HANGERS, WIRES, ETC.

4. EXISTING 2X4 CEILING GRIDS TO REMAIN. ADD INTERMEDIATE CEILING GRIDS

AS REQUIRED TO RECEIVE NEW 2X2 ACT CEILING TILES. OWNER TO PROVIDE

NEW CEILING TILES.

5. REPAIR EXISTING CEILING GRIDS AS REQUIRED TO RECEIVE NEW 2X2 ACT

CEILING TILES. OWNER TO PROVIDE NEW CEILING TILES.

6. INSTALL WIRELESS ACCESS POINT ON CEILING AS REQUIRED. REFER TO ELEC.

DWGS.

7. CORE DRILL EXISTING SLAB AS REQUIRED TO INSTALL FLUSH-MOUNTED

FLOOR BOXES. SEE ELEC. DWGS.

8. HATCHED AREA TO BE PROVIDED WITH CONTINUOUS 2-HOUR FIRE-RATED

SEPARATION. APPLY FIRE-PROOFING SPRAY TO EXISTING STRUCTURAL STEEL

MEMBERS AND DECKING AS REQUIRED. VERIFY COVERAGE & THICKNESS IN

FILED.

9. PROVIDE BLOCKING IN WALL AS REQUIRED TO INSTALL NEW ELEC. DEVICES.

PATCH AND REPAIR EXISTING GYPSUM BOARD. COORDINATE w/ ELEC. AND

OWNER.

10. CONTRACTOR TO PROVIDE 1/2" GYPSUM BOARD ON THE INSIDE OF EXTERIOR

WALLS ABOVE WINDOW/CEILING IN THE ENTIRE BUILDING TO ENCAPSULATE

EXISTING INSULATION AND VAPOR BARRIER.

11. EXTEND EXISTING METAL FRAMING AND GYPSUM BOARD TO THE UNDERSIDE

OF EXISTING DECK. SEE 9/A490.

12. REBUILD COLUMN WRAP/GYPSUM FINISH TO MATCH EXISTING. SEE 2/A110.

13. NO NEW CEILING WORK IN THE AREA.

Cxx

LOWER LEVEL PLAN

A110

Drawing Title:Revised By:Date:Description:Revision:Project Title: Date:

Scale:

Drawn By:

Project Number:

Drawing Number:

SILVER PETRUCELLI + ASSOCIATES

203 230 9007

3190 WHITNEY AVENUE HAMDEN CT 06518

silverpetrucelli.com

311 STATE STREET NEW LONDON CT 06320

Project Phase:

25-106

06/12/2026

BID SET

INTERIOR RENOVATIONS FOR:

BOARD OF EDUCATION CENTRAL OFFICE

50 NYE ROAD

GLASTONBURY, CONNECTICUT 06033

As Indicated

1 LOWER LEVEL PLAN

1/8"=1'-0"

-7

'-0

3'- 4"

3'- 6"

1+/ -9

'-3

3'- 4"1'- 3"

5'- 0"

-1

1'- 1"

5'-9" 6'-4" +/-16'-8"

3'-4"

ALIGN

BOTH SIDES

ALIGN

BOTH SIDES

ALIGN

+/-3'-2"3'-4"

C01

C01

C01 C01

C01

C01 C01

C01

C01

C01

C01

118A

119 120 121 122.1

122.2

124.1

124.2

127131

109110111112113114

105.3

105.2

105.1

105B

105A

ST1.1

C105A.1 C105A.2 C105B

C107A

C103A

C102.1

C102.2

ST2.1.2

ST2.1.1

120A

A490

A490

C100A.1 C100A.2

133A

S.Liu

1ALIGN

BOTH SIDES

ALIGN

BOTH SIDES

5'-0" 1

5'-0"

5'-6"

'-9

28'-8"

EX.FLOOR HATCH

EX.FLOOR HATCH

2'-6" 6'-4" 20'-3"

C100.1

C100.2

-5

'-6 1 2"

11"

ALIGN

2 TYPICAL INTERIOR COLUMN

1 1/2"=1'-0"

GFRG PREFABRICATED COLUMN

COVER TO MATCH EXISTING

EXISTING METAL COLUMN

COORDINATE FIRE-PROOFING w/

EXISTING METAL STUD COLUMN

COVER BRACE TO MAINTAIN

CONTINUOUS FIRE-RESISTIVE

PROTECTION.

EXISTING METAL ANGLE BASE

SUPPORT

FIRE-PROOFING SPRAY TO

ACHIEVE 2HR RATED FIRE

SEPARATION, SEE

CONSTRUCTION NOTE C08.

C12

C12

C12

C12

C12 C12

C12

C12C12

C12

C12

C01

EXISTING DEPRESSED

SLAB WITH RAISED

FLOOR WITHIN EXTENT

OF PHANTOM LINE.

C01

ALIGN

+/-6'-4"

AL

IG

N 2

2'- 2"

3'- 2"

CENTER OVERALL DOOR

FRAME OPENING

BETWEEN ENDS OF NEW

WALL SEGMENT.

UNEQUAL DOOR LEAF

WIDTHS SHALL BE AS

SCHEDULED.

6" 3'-4"

C12

PHANTOM LINE INDICATE EXISTING DEPRESSED SLAB

WITH RAISED FLOOR.

C01C01

C01

C01

WORK SPACE

CONFERENCE ROOM

OFFICE

OFFICE

CONFERENCE ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

JAN.

SUPPLY CLOSET

H.C. TOILET

ELEC.

C201A

MEN'S TOILET

WOMEN'S TOILET

CORRIDOR

C203

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

LOBBY

235CONFERENCE ROOM

MEN'S TOILET

WOMEN'S TOILET

KITCHEN

C205A

H.C. TOILET

STOR.

234B

STOR.

234A

ELEC.

C206A

STOR.

C206B

STORAGE

C206C

C204A

15 SF

CORRIDOR

C204

CORRIDOR

C200

CORRIDOR

C202

KITCHEN

C202A

CORRIDOR

C201

CORRIDOR

C205

CORRIDOR

C206

CORRIDOR

C207

KITCHEN

C200A

STAIR

ST2.2

STAIR

ST1.2

ELEVATOR

EL1.2

OFFICE

OFFICE

EX.LADDER

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6

EX.7 EX.8

EX.X

EX.1 EX.2 EX.3 EX.4 EX.5 EX.5.1

EX.D

EX.C

EX.B

EX.A

EX.Z

EX.Y-4

EX.Y

EX.6

EX.7 EX.8

EX.X

C07

C07

C07 C07

C07

C07

PLAN SYMBOL LEGEND

EXISTING WALLS TO REMAIN

CONSTRUCTION NOTES - SEE DWG. A110

### DOOR TAG

Cxx

EXISTING DOORS TO REMAIN

NEW WALL

NEW DOOR, ALL NEW DOORS AND METAL FRAMES

N.I.C. SEE GENERAL NOTE #8

ROOM TAG

1 WALL TAG

A110

DETAIL BOX

DETAIL BUBBLE TAG

GENERAL NOTES

1. READ ALL GENERAL NOTES ON DRAWING G100.

2. INTERIOR PARTITION DIMENSIONS ARE FROM OUTSIDE FACE OF GWB,

MASONRY, OR CONCRETE.

3. CONTRACTORS SHALL FIELD VERIFY ALL CONDITIONS & DIMENSIONS.

4. PATCH TO MATCH ALL EXISTING WALLS, CEILINGS, & SURFACES TO REMAIN

THAT ARE AFFECTED BY THE NEW WORK.

5. ALL NEW WALL & PARTITION ASSEMBLIES SHALL EXTEND TO UNDERSIDE OF

DECK UNLESS OTHERWISE NOTED.

6. WHERE THE WORD "ALIGN" IS INDICATED IT SHALL MEAN TO ALIGN BOTH SIDES

OF WALL.

7. SEE M/E/P DRAWINGS TO COORDINATE NEW OPENINGS REQUIRED IN WALLS

TO ACCOMMODATE NEW DUCTS, PIPES, & CONDUITS. FRAME AND SEAL

OPENINGS AS REQUIRED.

OFFICE

CONSTRUCTION NOTES

1. PATCH & REPAIR AT PARTITION WALL TO MATCH EXISTING. PROVIDE SMOOTH

SURFACE…