2-Appendix A - Parts List - E-Rate 2026.xlsx
XLSX spreadsheet 194 KB Posted
- Attached to
- Data Cable RFP - Pond Elementary
- Solicitation number
- 26-13101
- Issued by
- Missouri
About this file
This file is an Appendix A Parts List for the Rockwood School District's E-Rate 2026 Data Cable RFP for Pond Elementary in Missouri. The document provides a comprehensive inventory of networking and telecommunications equipment required for the project, including Cat 6A plenum cabling from manufacturers such as Berk-Tek, Belden, and Superior Essex; structured cabling components including Ortronics HDJ faceplates and panels in various configurations (2-hole, 3-hole, 4-hole, and 6-hole options); Clarity 10G patch panels in 24-port and 48-port formats; cable management systems including Mighty Mo racks and Chatsworth Products universal racks; and Belden KeyConnect patch panels in multiple port densities. The parts list also specifies fiber optic cabling infrastructure from Corning, including singlemode and multimode fiber options with various strand counts (6-fiber through 48-fiber configurations), MIC DX tight-buffered armored cables, FREEDM loose-tube and tight-buffered plenum cables, and associated closet connector housings and field-installable connectors. Additionally, the list includes wall-mountable and rack-mountable hardware from Panduit and other manufacturers for cable termination and management.
The Appendix A parts list does not contain pricing information, set-asides, contract duration terms, response dates, or other commercial terms. The document serves as a detailed bill of materials and equipment specifications for bidders responding to the Rockwood School District's request to provide and install Cat 6A drops, IDF racks and cabinets, and a fiber campus backbone infrastructure. The specification of multiple manufacturers and product models suggests the district's intent to allow flexibility in bidder sourcing while maintaining performance standards and compatibility requirements for the network infrastructure project across multiple school buildings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 4-26-13101 Addendum 1.pdf | ||
| 6-26-13101 Addendum 1.pdf | ||
| 5-Appendix B.pdf | ||
| 1-Acknowledgement Form.pdf | ||
| 3-Pond 2026.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Rockwood School District - Appendix A | ||
| Wire | ||
| Berk-Tek | ||
| LANmark-10G Cat 6A Plenum | 10137385 | |
| Belden | ||
| 10GX System UTP Cable | 10GX130042500 | |
| 10GXW System UTP Cable | 10GXW13004 | |
| Superior Essex | ||
| Superior Essex 10Gain XP Cat 6A | CMP 6A-246-6B / CMP 6A-272-6B | |
| Ortronics | ||
| HDJ 2 hole faceplate | OR-403HDJ12 | fog white |
| HDJ 3 hole faceplate | OR-403HDJ13 | fog white |
| HDJ 6 hole faceplate | OR-403HDJ16 | fog white |
| HDJ 4 hole faceplate | OR-403HDJ14 | fog white |
| HDJ Blank Modules | OR-HDJB20 | fog white |
| OR-404HDJ1 | One Port HDJ Pleunum / Surface Mount Box | |
| OR-404HDJ2 | Two Port HDJ Plenum / Surface Mount Box | |
| Clarity 10G 24-port panel, Cat6a, six-port modules, 19" x 1.75" | OR-PHD610U24 | |
| Clarity 10G 48-port panel, Cat6a, six-port modules, 19" x 3.5" | OR-PHD610U48 | |
| Clarity Cat6a 24 port flat panel, 110/6port , T568A/B, 1.75 x 19, HD | OR-PHD6AU24 | |
| Clarity Cat6a 48 port flat panel, 110/6port , T568A/B, 3.5 x 19, HD | OR-PHD6AU48 | |
| HDJ Series 24 Port 2RU Standard Density | OR-PHDHJU24 | |
| HDJ Series 48 Port 2RU Standard Density | OR-PSDHJU48 | |
| Clarity Cat6a High Density jack RJ45 | OR-HDJ6A-36 | High Density Jack - Blue |
| Clarity Cat6a High Density jack RJ45 | OR-HDJ6A-88 | High Density Jack - White |
| Direct Attach 6A | HDPUC6A-5PK | Used to Connect IP Cameras |
| Data Rack | ||
| HDPUC6A-5PK | Mighty Mo 6 Cable Management Rack 6" deep | |
| OR-MM6VMD706 | Mighty Mo 6 Cable Management Cage with door | |
| OR-19-84-T2SDB | 19" DirectPatch Cable Management Rack, 3" Channel Black | |
| DVMS704 | Double Sideed Standard Vertical Cable Management Cage w/covers | |
| URT10-12B | Tubular Runway 12"W Black | |
| OR-P128240HB | Wall Angle Assembly 12" Runway Black | |
| Wall Cabinet | ||
| SWM12RUPD-26-26 | 12U X 26" W X 28"D PlexiDoor | |
| OR-SWM18RUPL-26-26 | 18U X 26" W X 28"D PlexiDoor | |
| OR-SWM26RUPL-26-26 | 26U X 26" W X 28"D PlexiDoor | |
| VWMFK-115 | Fan Kit, 4", 50cfm | |
| Chatsworth Products | ||
| 48353-703 | 19”W Universal Rack - UL Listed | 84"H x 19"W, 45U |
| 48353-720 | 19”W Universal Rack - UL Listed | 48"H x 19"W, 24U |
| 11583-519 | Flush Mounted Wall Bracket | 19" rack |
| 57004-X03 | 19"W Rack with 6" Vertical Cable MGMT | 19" Rack 45U |
| 11911-712 | Cable runway Wall to Rack | Wall to Rack Runway |
| Belden | ||
| AX103114 | 24 port 1u emptykeystone | |
| AX103115 | 48 port 2u empty keystone | |
| AX103116 | 72 port 2u keystone | |
| 10GX Patch Panels | AX103254 | 24 port, 1U, 10GX Keyconnect patch panel |
| 10GX Patch Panels | AX103256 | 48 port, 2U, 10GX Keyconnect patch panel |
| T568A/B | AX103073 | Copper - Category 6A - 10GX Modular Jacks - KeyConnect |
| 1-port, with ID windows, single-gang | AX102660 | KeyConnect Faceplate |
| 2-port, with ID windows, single-gang | AX102655 | KeyConnect Faceplate |
| 4-port, with ID windows, single-gang | AX102249 | KeyConnect Faceplate |
| 6-port, with ID windows, single-gang | AX102251 | KeyConnect Faceplate |
| CAT6+ KeyConect Patch Panel, 24 port, 1U | AX103114 | KeyConnect patch Panel |
| CAT6+ KeyConect Patch Panel, 48 port, 2U | AX103115 | KeyConnect patch Panel |
| Corning | ||
| 006E68-31131-29 | 6 F, 2.9 mm Subunits, Singlemode | six strands fiber singlemode |
| 012E68-31131-29 | 12 F, 2.99 mm Subunits, Singlemode | 12 strands fiber singlemode |
| 006T88-31190-D3 | MIC® DX Tight-Buffered Armored Cable | 6 F, 50 µm multimode (OM4) |
| 012T88-31190-D3 | MIC® DX Tight-Buffered Armored Cable | 6 F, 50 µm multimode (OM4) |
| 048T88-31190-D3 | MIC® DX Tight-Buffered Armored Cable | 6 F, 50 µm multimode (OM4) |
| 012ESP-T4101DA3 | FREEDM® Loose Tube, Gel-Free, Interlocking Armored Cable, Plenum, 12 F, Single-mode (OS2) | 12 fiber, single mode - indoor/outdoor |
| 012E8P-31131-A3 | FREEDM® One Tight-Buffered, Interlocking Armored Cable, Plenum, 12 F, Single-mode (OS2) | 12 fiber, single mode - indoor/outdoor |
| 024ESP-T4101DA3 | FREEDM® Loose Tube, Gel-Free, Interlocking Armored Cable, Plenum, 24 F, Single-mode (OS2) | 24 fiber, single mode - indoor/outdoor |
| 024E8P-31131-A3 | FREEDM® One Tight-Buffered, Interlocking Armored Cable, Plenum, 24 F, Single-mode (OS2) | 24 fiber, single mode - indoor/outdoor |
| 048E8P-31131-A3 | FREEDM® One Tight-Buffered, Interlocking Armored Cable, Plenum, 48 F, Single-mode (OS2) | 48 fiber, single mode - indoor/outdoor |
| 006TSF-T4190DA1 | OUTDOOR 50 µm MM (OM4) | 6 F, 50 µm multimode (OM4) |
| 006T88-31190-A3 | 50 µm MM OM4 cable | 6 F, 50 µm multimode (OM4) |
| 024T88-31190-A3 | MIC Tight-Buffered, Interlocking Armored Cable, Plenum, 24 fiber, 50 µm multimode (OM4) | 24 F, 50 µm multimode (OM4) |
| 006T88-31191-A3 | 50 µm MM OM4+ cable (extd distance) | 6 F, 50 µm multimode (OM4+) |
| CCH-CS12-AD-P00QE | Closet Connector Housing, Pigtailed, LC Adapters | Duplex, 12 F, 50 µm multimode (OM4) |
| CCH - CS 06 - E4 - P00QE | Closet Connector Housing, Pigtailed, LC Adapters | Duplex, 6 F, 50 µm multimode (OM4) |
| CCH-CS24-AD-P00QE | Closet Connector Housing, Pigtailed, LC Adapters | Duplex, 24 F, 50 µm multimode (OM4) |
| CCH-CP06-E4 | Closet Connector Housing, LC Adapter | Duplex, 6 F, 50 µm multimode (OM3/4) |
| CCH-CP12-A9 | LC Adapter 0S2 12 Fiber | |
| CCH-01U | Closet Conector Housing | 2 panel |
| CCH-02U | Closet Connector Housing | 4 panel |
| CCH-CS12-E4-P00RE | CCH Pigtailed Splice Cassette, 12 F, Multi-mode fiber (OM4), (50 µm) | |
| CCH-01U | Rack 19-in, Rack 23-in, Cabinet-mount | one rack unit, holds two CCH connector panels |
| CCH-02U | Rack 19-in, Rack 23-in, Cabinet-mount | two rack units, holds four CCH connector panels |
| CCH-03U | Rack 19-in, Rack 23-in, Cabinet-mount | three rack units, holds six CCH connector panels |
| CCH-04U | Rack 19-in, Rack 23-in, Cabinet-mount | four rack units, holds 12 CCH connector panels |
| CCH-CS12-AE-P00RE | CCH Pigtailed Splice Cassette, 12 F, LC UPC duplex, Single-mode (OS2), single-fiber (250 µm) | splice cassette |
| CCH-CS24-AE-P00RE | CCH Pigtailed Splice Cassette, 24 F, LC UPC duplex, Single-mode (OS2), single-fiber (250 µm) | splice cassette |
| CCH-CF | Termination and Slack Storage, empty, for one CCH adapter panel | Rack-Mountable Hardware |
| CCH-CS | Splicing, empty, for one CCH adapter panel | Rack-Mountable Hardware |
| 2806031-01 | Heat Shrink Fusion Splice |
| FL2-LC-900-OM4-6 | 50 µm multimode (OM2/3/4) | Field-Installable Connectors |
| FL2-LC-2MM-OM4-6 | 50 µm multimode (OM2/3/4) | Field-Installable Connectors |
| 96-050-51-X-2 | ST 50/125 SX | 25 pack / field-installable connectors |
| 95-051-98-SP-X | Field-Installable Connectors | 50 µm multimode (OM3/OM4/OM4 extended 10G distance) |
| WCH-02P | Wall-Mountable Connector Housing | Holds 2 CCH connector panels/cassettes |
| WCH-04P | Wall-Mountable Connector Housing | Holds 4 CCH connector panels/cassettes |
| WCH-06P | Wall-Mountable Connector Housing | Holds 6 CCH connector panels/cassettes |
| Panduit | ||
| LDWH6-A | Nonmetallic raceway 6' L x 1.01" H | LD5 Adhesive |
Sheet2
Sheet3
File details come from the government source that posted it. Updated .