This is an Appendix A Parts List for an E-Rate 2026 project issued by Rockwood School District in Missouri, detailing the comprehensive materials and equipment specifications required for a data cable and network infrastructure installation project at Wildwood Middle School and multiple school buildings within the District.
The parts list specifies a detailed inventory of networking equipment organized by manufacturer and product category, including copper cabling systems from Wire, Berk-Tek, Belden, and Superior Essex (Cat 6A plenum and 10GX UTP cables); connection hardware from Ortronics (HDJ faceplates, modules, and clarity patch panels in 24-port and 48-port configurations); rack and cabinet infrastructure from multiple vendors (wall cabinets ranging from 12U to 26U, universal racks from 24U to 45U, and cable management systems); and comprehensive fiber optic infrastructure from Corning (singlemode and multimode fiber cables ranging from 6 to 48 fiber counts, closet connector housings, splice cassettes, and field-installable connectors in various configurations). The specification also includes equipment from Chatsworth Products for cooling and mounting solutions and Panduit for nonmetallic raceway. The materials appear designed to support both copper-based data drops and fiber campus backbone connectivity across multiple buildings.
The parts list does not include pricing information, specific quantities per item, delivery timelines, bid submission dates, or contract award dates in this document. As an appendix focused on technical specifications rather than procurement terms, it serves as the detailed bill of materials for vendors to reference when preparing bids. The E-Rate funding designation indicates this project qualifies for federal Universal Service Fund support through the Schools and Libraries Program, which typically underwrites eligible network infrastructure improvements for educational institutions.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-Acknowledgement Form.pdf | ||
| 3-Wildwood 2026.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Rockwood School District - Appendix A | ||
| Wire | ||
| Berk-Tek | ||
| LANmark-10G Cat 6A Plenum | 10137385 | |
| Belden | ||
| 10GX System UTP Cable | 10GX130042500 | |
| 10GXW System UTP Cable | 10GXW13004 | |
| Superior Essex | ||
| Superior Essex 10Gain XP Cat 6A | CMP 6A-246-6B / CMP 6A-272-6B | |
| Ortronics | ||
| HDJ 2 hole faceplate | OR-403HDJ12 | fog white |
| HDJ 3 hole faceplate | OR-403HDJ13 | fog white |
| HDJ 6 hole faceplate | OR-403HDJ16 | fog white |
| HDJ 4 hole faceplate | OR-403HDJ14 | fog white |
| HDJ Blank Modules | OR-HDJB20 | fog white |
| OR-404HDJ1 | One Port HDJ Pleunum / Surface Mount Box | |
| OR-404HDJ2 | Two Port HDJ Plenum / Surface Mount Box | |
| Clarity 10G 24-port panel, Cat6a, six-port modules, 19" x 1.75" | OR-PHD610U24 | |
| Clarity 10G 48-port panel, Cat6a, six-port modules, 19" x 3.5" | OR-PHD610U48 | |
| Clarity Cat6a 24 port flat panel, 110/6port , T568A/B, 1.75 x 19, HD | OR-PHD6AU24 | |
| Clarity Cat6a 48 port flat panel, 110/6port , T568A/B, 3.5 x 19, HD | OR-PHD6AU48 | |
| HDJ Series 24 Port 2RU Standard Density | OR-PHDHJU24 | |
| HDJ Series 48 Port 2RU Standard Density | OR-PSDHJU48 | |
| Clarity Cat6a High Density jack RJ45 | OR-HDJ6A-36 | High Density Jack - Blue |
| Clarity Cat6a High Density jack RJ45 | OR-HDJ6A-88 | High Density Jack - White |
| Direct Attach 6A | HDPUC6A-5PK | Used to Connect IP Cameras |
| Data Rack | ||
| HDPUC6A-5PK | Mighty Mo 6 Cable Management Rack 6" deep | |
| OR-MM6VMD706 | Mighty Mo 6 Cable Management Cage with door | |
| OR-19-84-T2SDB | 19" DirectPatch Cable Management Rack, 3" Channel Black | |
| DVMS704 | Double Sideed Standard Vertical Cable Management Cage w/covers | |
| URT10-12B | Tubular Runway 12"W Black | |
| OR-P128240HB | Wall Angle Assembly 12" Runway Black | |
| Wall Cabinet | ||
| SWM12RUPD-26-26 | 12U X 26" W X 28"D PlexiDoor | |
| OR-SWM18RUPL-26-26 | 18U X 26" W X 28"D PlexiDoor | |
| OR-SWM26RUPL-26-26 | 26U X 26" W X 28"D PlexiDoor | |
| VWMFK-115 | Fan Kit, 4", 50cfm | |
| Chatsworth Products | ||
| 48353-703 | 19”W Universal Rack - UL Listed | 84"H x 19"W, 45U |
| 48353-720 | 19”W Universal Rack - UL Listed | 48"H x 19"W, 24U |
| 11583-519 | Flush Mounted Wall Bracket | 19" rack |
| 57004-X03 | 19"W Rack with 6" Vertical Cable MGMT | 19" Rack 45U |
| 11911-712 | Cable runway Wall to Rack | Wall to Rack Runway |
| Belden | ||
| AX103114 | 24 port 1u emptykeystone | |
| AX103115 | 48 port 2u empty keystone | |
| AX103116 | 72 port 2u keystone | |
| 10GX Patch Panels | AX103254 | 24 port, 1U, 10GX Keyconnect patch panel |
| 10GX Patch Panels | AX103256 | 48 port, 2U, 10GX Keyconnect patch panel |
| T568A/B | AX103073 | Copper - Category 6A - 10GX Modular Jacks - KeyConnect |
| 1-port, with ID windows, single-gang | AX102660 | KeyConnect Faceplate |
| 2-port, with ID windows, single-gang | AX102655 | KeyConnect Faceplate |
| 4-port, with ID windows, single-gang | AX102249 | KeyConnect Faceplate |
| 6-port, with ID windows, single-gang | AX102251 | KeyConnect Faceplate |
| CAT6+ KeyConect Patch Panel, 24 port, 1U | AX103114 | KeyConnect patch Panel |
| CAT6+ KeyConect Patch Panel, 48 port, 2U | AX103115 | KeyConnect patch Panel |
| Corning | ||
| 006E68-31131-29 | 6 F, 2.9 mm Subunits, Singlemode | six strands fiber singlemode |
| 012E68-31131-29 | 12 F, 2.99 mm Subunits, Singlemode | 12 strands fiber singlemode |
| 006T88-31190-D3 | MIC® DX Tight-Buffered Armored Cable | 6 F, 50 µm multimode (OM4) |
| 012T88-31190-D3 | MIC® DX Tight-Buffered Armored Cable | 6 F, 50 µm multimode (OM4) |
| 048T88-31190-D3 | MIC® DX Tight-Buffered Armored Cable | 6 F, 50 µm multimode (OM4) |
| 012ESP-T4101DA3 | FREEDM® Loose Tube, Gel-Free, Interlocking Armored Cable, Plenum, 12 F, Single-mode (OS2) | 12 fiber, single mode - indoor/outdoor |
| 012E8P-31131-A3 | FREEDM® One Tight-Buffered, Interlocking Armored Cable, Plenum, 12 F, Single-mode (OS2) | 12 fiber, single mode - indoor/outdoor |
| 024ESP-T4101DA3 | FREEDM® Loose Tube, Gel-Free, Interlocking Armored Cable, Plenum, 24 F, Single-mode (OS2) | 24 fiber, single mode - indoor/outdoor |
| 024E8P-31131-A3 | FREEDM® One Tight-Buffered, Interlocking Armored Cable, Plenum, 24 F, Single-mode (OS2) | 24 fiber, single mode - indoor/outdoor |
| 048E8P-31131-A3 | FREEDM® One Tight-Buffered, Interlocking Armored Cable, Plenum, 48 F, Single-mode (OS2) | 48 fiber, single mode - indoor/outdoor |
| 006TSF-T4190DA1 | OUTDOOR 50 µm MM (OM4) | 6 F, 50 µm multimode (OM4) |
| 006T88-31190-A3 | 50 µm MM OM4 cable | 6 F, 50 µm multimode (OM4) |
| 024T88-31190-A3 | MIC Tight-Buffered, Interlocking Armored Cable, Plenum, 24 fiber, 50 µm multimode (OM4) | 24 F, 50 µm multimode (OM4) |
| 006T88-31191-A3 | 50 µm MM OM4+ cable (extd distance) | 6 F, 50 µm multimode (OM4+) |
| CCH-CS12-AD-P00QE | Closet Connector Housing, Pigtailed, LC Adapters | Duplex, 12 F, 50 µm multimode (OM4) |
| CCH - CS 06 - E4 - P00QE | Closet Connector Housing, Pigtailed, LC Adapters | Duplex, 6 F, 50 µm multimode (OM4) |
| CCH-CS24-AD-P00QE | Closet Connector Housing, Pigtailed, LC Adapters | Duplex, 24 F, 50 µm multimode (OM4) |
| CCH-CP06-E4 | Closet Connector Housing, LC Adapter | Duplex, 6 F, 50 µm multimode (OM3/4) |
| CCH-CP12-A9 | LC Adapter 0S2 12 Fiber | |
| CCH-01U | Closet Conector Housing | 2 panel |
| CCH-02U | Closet Connector Housing | 4 panel |
| CCH-CS12-E4-P00RE | CCH Pigtailed Splice Cassette, 12 F, Multi-mode fiber (OM4), (50 µm) | |
| CCH-01U | Rack 19-in, Rack 23-in, Cabinet-mount | one rack unit, holds two CCH connector panels |
| CCH-02U | Rack 19-in, Rack 23-in, Cabinet-mount | two rack units, holds four CCH connector panels |
| CCH-03U | Rack 19-in, Rack 23-in, Cabinet-mount | three rack units, holds six CCH connector panels |
| CCH-04U | Rack 19-in, Rack 23-in, Cabinet-mount | four rack units, holds 12 CCH connector panels |
| CCH-CS12-AE-P00RE | CCH Pigtailed Splice Cassette, 12 F, LC UPC duplex, Single-mode (OS2), single-fiber (250 µm) | splice cassette |
| CCH-CS24-AE-P00RE | CCH Pigtailed Splice Cassette, 24 F, LC UPC duplex, Single-mode (OS2), single-fiber (250 µm) | splice cassette |
| CCH-CF | Termination and Slack Storage, empty, for one CCH adapter panel | Rack-Mountable Hardware |
| CCH-CS | Splicing, empty, for one CCH adapter panel | Rack-Mountable Hardware |
| 2806031-01 | Heat Shrink Fusion Splice |
| FL2-LC-900-OM4-6 | 50 µm multimode (OM2/3/4) | Field-Installable Connectors |
| FL2-LC-2MM-OM4-6 | 50 µm multimode (OM2/3/4) | Field-Installable Connectors |
| 96-050-51-X-2 | ST 50/125 SX | 25 pack / field-installable connectors |
| 95-051-98-SP-X | Field-Installable Connectors | 50 µm multimode (OM3/OM4/OM4 extended 10G distance) |
| WCH-02P | Wall-Mountable Connector Housing | Holds 2 CCH connector panels/cassettes |
| WCH-04P | Wall-Mountable Connector Housing | Holds 4 CCH connector panels/cassettes |
| WCH-06P | Wall-Mountable Connector Housing | Holds 6 CCH connector panels/cassettes |
| Panduit | ||
| LDWH6-A | Nonmetallic raceway 6' L x 1.01" H | LD5 Adhesive |