2-2610 - Bethel Twp building 6.17.2026 Bid Set.pdf

PDF 9 MB Posted

Attached to
Bethel Township's Municipal Storage Building Project
Solicitation number
Not on record
Issued by
Lehigh County, Pennsylvania

About this file

This is a bid set document for Bethel Township's Municipal Storage Building Project in Lebanon County, Pennsylvania, consisting of architectural drawings and specifications for construction of a 3,600 square foot accessory storage garage building. The project is located at 01 South Pine Grove Street, Fredericksburg, PA 17026. The building design includes a single-story garage structure with four 14'x14' overhead doors, manual entry doors, concrete apron areas, and internal storage and rack systems. A mandatory pre-bid meeting is scheduled for July 22, 2026 at 3 p.m. at the Bethel Township Building. Electronic bids will be accepted through PennBID until 12 noon on August 13, 2026, with public opening and reading at 7:00 p.m. the same day at the Bethel Township Board of Supervisors' meeting. Bethel Township anticipates completion of the work prior to the end of 2026 calendar year, and a construction schedule from each bidder will be required and evaluated as part of the bid review process.

The bid requires submission of a bid security equal to 10% of the bid amount, with the successful bidder required to furnish Performance and Payment Bonds each in an amount equal to 100% of the contract value within 20 days of award. All proposals must remain irrevocable for sixty days after the bid opening date. The project is subject to Pennsylvania Department of Labor and Industry's Prevailing Wage Determination requirements, with contractors obligated to pay prevailing minimum rates as established under the Prevailing Wage Act. The architectural and engineering drawings specify detailed construction requirements including 8-inch poured concrete foundation walls extending 4 feet above grade, 6-inch concrete slab flooring with vapor barrier and crushed stone base, pre-engineered wood trusses, 28-gauge steel roofing and siding, mechanical, electrical, and plumbing systems with provisions for future natural gas heating, and full compliance with 2019 ACI concrete standards, 2018 NDS wood design standards, 2020 National Electrical Code, and applicable local codes.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWN BY: PROJECT PHASE:

SCALE: DATE:

TH

E

C O

N

TR

A C

TO

R S

H A

LL

C H

EC

K C O

N D

IT

IO

N S

IN

P

LA

C E

A N D

O B

TA

IN

O

R V

ER

IF

Y

A

LL

N

EC

ES

S A R Y

D

IM

EN

S

IO

N S

B

EF

O R E

B

EG

IN

N

IN

G W

O R K

JOB NO:

DRAWING NO:

AS NOTED

REVISIONS:

S O

U

TH

P

IN

E G

R O

V E

S

TR

EE

T

FR

ED

ER

IC

KS

B U R G

PA

B

ET

H

EL

T O

W N S H

IP

LE

B A N O

N C

O U N

TY

JUNE 8, 2026

E ld on R

. S to lt zf us , A rc hi te ct

Ph on e:

(7

) 2

-5

F ax

7)

-9

E -m ai l:

es to ltz fu s@ er sa rc hi te ct .c om

Ar ch ite ct ur e

Pl an ni ng

In te rio r D es ig n

W

IT

H O

U T

H

IS

P

ER

M

IS

SI

O

N A

N D

U N

LE

SS

T H

E R

EP

R

O D

U C

TI

O

N C

AR

R

IE

S

H

IS

N

AM

E

AS

T H

E

AR

C H

IT

EC

T

TH

IS

D

R

AW

IN

G

A S

AN

IN

ST

R

U M

EN

T

O F

SE

R

VI

C

E

IS

T H

E

PR

O

PE

R

TY

O F

TH

E

AR

C

H

IT

EC

T

AN

D

M

AY

N O

T

BE

R

EP

R O

D U

C

ED

So ut h

D ec at ur

S tre et

St ra sb ur g, P en ns yl va ni a

B

ET

H

EL

T O

W N S H

IP

M U N

IC

IP

A L

G A R A G

E

PERMIT SUBMITTAL

CS

INDEX OF DRAWINGS

LOCATION MAP

CS COVER SHEET

A-1 FLOOR PLAN

A-2

BETHEL TOWNSHIP

MUNICIPAL GARAGE

A-3 ELEVATIONS

A-4 ELEVATIONS, SECTIONS

�01� SOUTH PINE GROVE STREET

FREDERICKSBURG, PA 1�026

BETHEL TOWNSHIP, LEBANON COUNTY

FOUNDATION PLAN

A-5 WALL SECTIONS

SITE

MEP MECHANICAL, ELECTRIC, PLUMBING PLAN

A-6 SPECIFICATIONS

LOADING NOTES

DEAD LOADS

ROOF: 10 PSF WALLS: 10 PSF

LIVE LOAD

ROOF: 30 PSF

SNOW LOADS

GROUND SNOW LOAD (PG): 30 PSF

SNOW IMPORTANCE FACTOR (I): 1.0

SNOW EXPOSURE FACTOR (CE): 1.0

SNOW THERMAL FACTOR (CT): 1.1

WIND LOADS

ULTIMATE WIND SPEED (V): 115 MPH

RISK CATEGORY 2

WIND EXPOSURE CATEGORY: B

FOUNDATION NOTES

REMOVE ALL ORGANIC MATERIAL, EXCESSIVELY SOFT OR LOOSE SOIL, ASPHALT, CONCRETE,

OR OTHER DEBRIS WITHIN THE LIMITS OF THE FOUNDATIONS.

USE ON-SITE GRANULAR SOILS FOR FILL. PLACE FILL IN LIFTS NOT EXCEEDING 6" IN LOOSE

THICKNESS AND COMPACT TO 95% MAXIMUM DRY DENSITY PER ASTM D-1557,

STANDARD PROCTOR TEST

FOUNDATIONS ARE DESIGNED BASED ON A PRESUMPTIVE ALLOWABLE BEARING PRESSURE

OF 2,000 PSF. BEARING CAPACITY SHALL BE VERIFIED WITH ON-SITE TESTING.

CONCRETE NOTES

CONDUCT ALL CONCRETE WORK IN ACCORDANCE WITH THE 2019 EDITION OF ACI 318.

PROVIDE THE FOLLOWING CONCRETE COVER ON REINFORCEMENT BARS EXCEPT AS

NOTED:

CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"

CONCRETE EXPOSED TO EARTH OR WEATHER:

#5 BARS OR SMALLER: 1 1/2"

#6 BARS OR LARGER: 2"

USE CONCRETE WITH COMPRESSIVE STRENGTH AT 28-DAYS AS FOLLOWS:

FOUNDATIONS: 3,000 PSI SLABS: 4,000 PSI

PROVIDE GRADE 60 REINFORCEMENT BARS THAT MEET THE REQUIREMENTS OF ASTM A 615

WELDING OF REINFORCEMENT BARS DURING FABRICATION OR CONSTRUCTION IS NOT

PERMITTED.

WOOD NOTES

ALL TIMBER IS DESIGNED IN ACCORDANCE WITH THE 2018 EDITION OF THE NDS

USING ALLOWABLE STRESS METHOD.

USE #2 SPF FOR ALL DIMENSIONAL LUMBER UNLESS NOTED OTHERWISE

PROVIDE 2500 F-2.0E LVL BEAMS

PROVIDE 2600 F-2.0E SOUTHERN PINE MSR LUMBER

DESIGN, MANUFACTURE, AND ERECT PRE-ENGINEERED WOOD TRUSSES IN

ACCORDANCE WITH THE NDS FOR METAL PLATE CONNECTED WOOD TRUSS

CONSTRUCTION BY TRUSS PLATE INSTITUTE

PROVIDE PRESSURE TREATED WOOD THAT IS TREATED IN ACCORDANCE WITH AWPA

STANDARDS

USE WOOD TREATED WITH CHROMATED COPPER ARSENATE (CCA) OR EQUIVALENT.

USE HOT DIP GALVANIZED OR STAINLESS STEEL CONNECTORS ON PRESSURE TREATED LUMBER

A-3

SCALE:

A-1 1/4" = 1'-0"

FLOOR PLAN

90'-0" FOUNDATION

9"

9"

P/T 6x6 POSTS ON

CONCRETE WALL W/

STURDI-WALL SWP66

BASE CONNECTORS

6" CONC. FILLED

STEEL BOLLARD, TYP

(PAINT YELLOW)

'x

' O

.H D

O O

R

'x

' O .H

D

O O

R

5'-0"

CL

8'-0"

CL

5'-0"

CL

8'-0"

CL

CL

CL

CL

CL

2"11

2"

14'x14' O.H. DOOR 14'x14' O.H. DOOR 14'x14' O.H. DOOR

8'-0"

CL CL

14'-0" 8'-51 2" 14'-0" 6'-0" 14'-0" 6'-0"

5'-101 2" 11

2"

8'-23 4"

CL

8'-0"

CL CL

CL

8'-0"

CLCL

8'-0"3'-33 4"

3'-21 4"11

2"

6'-0" CONCRETE APRON

C O

N C R

E T E A

P R

O N

RACK SYSTEM RACK SYSTEM

RACK SYSTEM

26'-0"

D.S.D.S.D.S.D.S.

D.S. D.S. D.S. D.S.

A-3

A-4

A-3

A-4

A-4

STORAGE GARAGE

2x4 VERT. FIRE

BLOCKING BETWEEN

GIRTS, NAILED TO FACE

OF EACH POST, TYP

(INTERIOR & EXTERIOR)

METAL SIDING

METAL LINER

CEILING FINISH

16'-0" HEIGHT

FE

FE

WATER

HYDRANT/HOSE

BIBB

WATER SUPPLY

FROM ADJACENT

BUILDING

ELECTRIC CONDUIT

CONDUIT FOR FUTURE

NATURAL GAS LINE

(FUTURE GAS HEATER(S)

TACTILE EXIT SIGN

TACTILE EXIT SIGN

ALL DOORS TO BE INSULATED

3'x7' INSULATED METAL

DOOR W/ METAL FRAME

-PANIC HARDWARE

-EXTERIOR LEVEL LATCH

-H/C ACC. THRESHOLD

3'x7' INSULATED METAL

DOOR W/ METAL FRAME

-PANIC HARDWARE

-EXTERIOR LEVEL LATCH

-H/C ACC. THRESHOLD

(3) PLY 1 3/4 x 11 1/4" LVL HEADER

CONTINUOUS 2x12

MSR HEADER

BOTH SIDES OF

POSTS

ELECTRIC

PANEL

METAL LINER PANELS

ABOVE ON 2x4 WALL

GIRTS @ 24" OC MAX,

TYP

(3) PLY 1 3/4 x 11 1/4" LVL HEADER (3) PLY 1 3/4 x 11 1/4" LVL HEADER

'-9

"58'-2 1 2"

SLOPE CONC.

MIN. 1/8" / FT

SLOPE CONC.

MIN. 1/8" / FT

PROVIDE DRAFTSTOPPING IN ATTIC AREA, ATTIC

AREA NOT TO EXCEED 3,000 SF.

MATERIALS SHALL BE NOT LESS THAN 1/2-INCH

(12.7 MM) GYPSUM BOARD, 3/8-INCH (9.5 MM)

WOOD STRUCTURAL PANEL, 3/8-INCH (9.5 MM)

PARTICLEBOARD, 1-INCH (25-MM) NOMINAL

LUMBER, CEMENT FIBERBOARD, BATTS OR

BLANKETS OF MINERAL WOOL OR GLASS FIBER,

OR OTHER APPROVED MATERIALS ADEQUATELY

SUPPORTED.

SEE HEADER

CONNECTION DETAIL

5/A-5, TYP

SEE HEADER

CONNECTION

DETAIL 4/A-5, TYP

CONTINUOUS 2x12

MSR HEADER

BOTH SIDES OF

POSTS

SEE HEADER

CONNECTION

DETAIL 4/A-5, TYP

4'-0" HIGH POURED

CONCRETE WALL

METAL LINER PANELS

ABOVE ON 2x4 WALL

GIRTS @ 24" OC MAX,

TYP

4'-0" HIGH POURED

CONCRETE WALL

P/T 6x6 POSTS ON

CONCRETE WALL W/

STURDI-WALL SWP66

BASE CONNECTORS

90'-3"

2"11

2"

F O

UN

D

A T

IO

N

1 1/2" SPRAY FOAM

INSULATION OVER

CONCRETE WALL

(BETWEEN 2x4 WOOD

FURRING)

ADD ALTERNATE #1

GREASE INTERCEPTOR:

ROCKFORD # RGI-1000.

1,000 GALLON TANK W/

BAFFLE & TRAFFIC RATED

ACCESS LIDS.

ADD ALTERNATE #1

TRENCH DRAIN BY MONARCH

W/ STRUCTURAL STEEL COVER

1'-0" x 50'-0"

DESCRIPTIONMARK

EMERGENCY FIXTURE LEGEND

DUAL REMOTE EMERGENCY HEADS

EXIT SIGN - FACE AND DIRECTION ARROWS AS INDICATED

EXIT SIGN w/ REMOTE HEADS

EMERGENCY BATTERY UNIT

FE

20# ABC FIRE EXTINGUISHER (MIN. 2-A RATING)

TOP OF EXTINGUISHER AT 5'-0" MAX. A.F.F.

BOTTOM AT 4" MIN. A.F.F.

FE

RECESSED 20# ABC FIRE EXTINGUISHER (MIN. 2-A RATING)

TOP OF EXTINGUISHER AT 5'-0" MAX. A.F.F.

BOTTOM AT 4" MIN. A.F.F.

1. ALL EMERGENCY LIGHTS COMPLY w/ UL:94V-0

2. EMERGENCY LIGHTING TO BE CONNECTED TO LOCAL

LIGHTING CIRCUITS AHEAD OF ANY SWITCHING DEVICES.

3. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT

BE LESS THAN (1) ONE FOOTCANDLE AT THE WALKING

SURFACE

9"

4" THICK SIGNS W/

GRADE 2 BRAILLE (TYP)

1. CHARACTERS AND IDENTIFICATION SYMBOLS

ARE TO BE DISTINCTLY DIFFERENT FROM THE

BACKGROUND IN COLOR AND CONTRAST.

2.LETTERS AND NUMBERS ON SIGNS SHALL BE

RAISED 132" MIN., SHALL BE A MIN. OF 58" HIGH

AND MAX. OF 2" HIGH. CHARACTERS SHALL BE

UPPERCASE AND SANS-SERIF ACCOMPANIED

BY GRADE 2 BRAILLE.

3.PROVIDE IDENTIFICATION SIGN ON WALL TO

LATCH SIDE OF DOOR. WHERE SIGNS ARE

PROVIDED AT DOUBLE DOORS, THE SIGN

SHALL BE TO THE RIGHT OF THE RIGHT HAND

DOOR. WHERE NO WALL SPACE IS AVAILABLE

SIGNS SHALL BE ON THE NEAREST ADJACENT

WALL.F.F.

PROVIDE TACTILE SIGNS FOR ALL EGRESS EXITS

& HANDICAP ACCESSIBLE RESTROOMS.

SCALE:

A-1 1/4"=1'-0"

IDENTIFICATION SIGN ELEVATION

IDENTIFICATION SIGN

(SEE NOTE 3 FOR

LOCATION

ADA BRAILLE IDENTIFICATION SIGNS

ENTRANCE ACCESSIBLE EXIT

EXIT

RAISED CHARACTERS SHALL BE

48" MIN. ABOVE THE FLOOR,

MEASURED TO THE BASELINE OF

THE LOWEST RAISED CHARACTER

AND 60" MAX. ABOVE THE

FLOOR, MEASURED TO THE

BASELINE OF THE HIGHEST

RAISED CHARACTER

DRAWN BY: PROJECT PHASE:

SCALE: DATE:

TH

E

C O

N

TR

A C

TO

R S

H A

LL

C H

EC

K C O

N D

IT

IO

N S

IN

P

LA

C E

A N D

O B

TA

IN

O

R V

ER

IF

Y

A

LL

N

EC

ES

S A R Y

D

IM

EN

S

IO

N S

B

EF

O R E

B

EG

IN

N

IN

G W

O R K

JOB NO:

DRAWING NO:

AS NOTED

REVISIONS:

S O

U

TH

P

IN

E G

R O

V E

S

TR

EE

T

FR

ED

ER

IC

KS

B U R G

PA

B

ET

H

EL

T O

W N S H

IP

LE

B A N O

N C

O U N

TY

JUNE 11, 2026

E ld on R

. S to lt zf us , A rc hi te ct

Ph on e:

(7

) 2

-5

F ax

7)

-9

E -m ai l:

es to ltz fu s@ er sa rc hi te ct .c om

Ar ch ite ct rio r D es ig n

W

IT

H O

U T

H

IS

P

ER

M

IS

SI

O

N A

N D

U N

LE

SS

T H

E R

EP

R

O D

U C

TI

O

N C

AR

R

IE

S

H

IS

N

AM

E

AS

T H

E

AR

C H

IT

EC

T

TH

IS

D

R

AW

IN

G

A S

AN

IN

ST

R

U M

EN

T

O F

SE

R

VI

C

E

IS

T H

E

PR

O

PE

R

TY

O F

TH

E

AR

C

H

IT

EC

T

AN

D

M

AY

N O

T

BE

R

EP

R O

D U

C

ED

So ut h

D ec at ur

S sb ur g, P en ns yl va ni a

B

ET

H

EL

T O

W N S H

IP

M U N

IC

IP

A L

G A R A G

E

PERMIT SUBMITTAL

A-1

FL

O

O R P

LA

N

AutoCAD SHX Text

8" PVC

UNDERGROUND RAIN

LEADER TO EXISTING

STORM WATER BASIN

8" PVC UNDERGROUND

RAIN LEADER

8" PVC

UNDERGROUND

RAIN LEADER

SCALE:

A-2 1/4" = 1'-0"

FOUNDATION PLAN

D.S.D.S.D.S.D.S.

D.S. D.S. D.S. D.S.

6" CONC. FILLED

STEEL BOLLARD, TYP

(PAINT YELLOW)

6'-0" CONCRETE APRON

C O

N C R

E T E A

P R

O N

90'-0"

A-4

A-4

6" THICK CONCRETE SLAB W/

WWF 6x6 W1.4xW1.4

VAPOR BARRIER AND

6" CRUSHED STONE BASE

24"x2" RIGID

PERIMETER

INSULATION

SLOPE CONC.

MIN. 1/8" / FT

8" POURED CONCRETE FOUNDATION

WALLS, EXTEND TO 4'-0" ABOVE F.F.E.

W/ #6 VERT. BARS HOOKED INTO

FOOTING & #6 HORZ. BARS @ 24" OC

24"x2" RIGID

PERIMETER

INSULATION

24x12" CONC FOOTING

W/ (3) #6 CONT. BARS &

#6 TIES @ 32" OC

SLOPE CONC.

MIN. 1/8" / FT

ADD ALTERNATE #1

SLOPE CONC FLOOR TO

TRENCH DRAIN, TYPICAL

ADD ALTERNATE #1

GREASE INTERCEPTOR:

ROCKFORD # RGI-1000.

1,000 GALLON TANK W/

BAFFLE & TRAFFIC RATED

ACCESS LIDS.

ADD ALTERNATE #1

TRENCH DRAIN BY MONARCH

W/ STRUCTURAL STEEL COVER

1'-0" x 50'-0"

50'-0"

PIPE TO RAIN

LEADER

S L O

P E C

O N C

1/

F T

S L O

P E C

O N C

1/

F T

SLOPE CONC.

1/8" / FT

SLOPE CONC.

1/8" / FT

1" DEPRESSION AT ALL

OVERHEAD DOORS

(SLOPED CONC SILL)

DRAWN BY: PROJECT PHASE:

SCALE: DATE:

TH

E

C O

N

TR

A C

TO

R S

H A

LL

C H

EC

K C O

N D

IT

IO

N S

IN

P

LA

C E

A N D

O B

TA

IN

O

R V

ER

IF

Y

A

LL

N

EC

ES

S A R Y

D

IM

EN

S

IO

N S

B

EF

O R E

B

EG

IN

N

IN

G W

O R K

JOB NO:

DRAWING NO:

AS NOTED

REVISIONS:

S O

U

TH

P

IN

E G

R O

V E

S

TR

EE

T

FR

ED

ER

IC

KS

B U R G

PA

B

ET

H

EL

T O

W N S H

IP

LE

B A N O

N C

O U N

TY

JUNE 8, 2026

E ld on R

. S to lt zf us , A rc hi te ct

Ph on e:

(7

) 2

-5

F ax

7)

-9

E -m ai l:

es to ltz fu s@ er sa rc hi te ct .c om

Ar ch ite ct rio r D es ig n

W

IT

H O

U T

H

IS

P

ER

M

IS

SI

O

N A

N D

U N

LE

SS

T H

E R

EP

R

O D

U C

TI

O

N C

AR

R

IE

S

H

IS

N

AM

E

AS

T H

E

AR

C H

IT

EC

T

TH

IS

D

R

AW

IN

G

A S

AN

IN

ST

R

U M

EN

T

O F

SE

R

VI

C

E

IS

T H

E

PR

O

PE

R

TY

O F

TH

E

AR

C

H

IT

EC

T

AN

D

M

AY

N O

T

BE

R

EP

R O

D U

C

ED

So ut h

D ec at ur

S sb ur g, P en ns yl va ni a

B

ET

H

EL

T O

W N S H

IP

M U N

IC

IP

A L

G A R A G

E

PERMIT SUBMITTAL

A-2

FO

U N D

A

TI

O N P

LA

1ST FLR

0'-0"

EAVE HT.

16'-0"

SCALE:

A-3 1/4" = 1'-0"

EAST ELEVATION

D.S.

28 GA. STEEL SIDING (ABM)

OVER BUILDING PAPER

VAPOR BARRIER

28 GA. STEEL ROOF

(ABM)

D.S.D.S. D.S.

1'-0"

6" CONC. FILLED

STEEL BOLLARD, TYP

(PAINT YELLOW)

3 1/2" x 5/4

BORAL TRIM

PAINTED

1ST FLR

0'-0"

EAVE HT.

16'-0"

SCALE:

A-3 1/4" = 1'-0"

SOUTH ELEVATION

1'-6"

1 2

6" CONC. FILLED

STEEL BOLLARD, TYP

(PAINT YELLOW)

3 1/2" x 5/4

BORAL TRIM

PAINTED

SCALE:

A-3 1/4" = 1'-0"

NORTH ELEVATION

1'-6"

METAL ROOF TRIM

OVER 2x6 RAKE

28 GA. STEEL SIDING (ABM)

OVER BUILDING PAPER

VAPOR BARRIER

DRAWN BY: PROJECT PHASE:

SCALE: DATE:

TH

E

C O

N

TR

A C

TO

R S

H A

LL

C H

EC

K C O

N D

IT

IO

N S

IN

P

LA

C E

A N D

O B

TA

IN

O

R V

ER

IF

Y

A

LL

N

EC

ES

S A R Y

D

IM

EN

S

IO

N S

B

EF

O R E

B

EG

IN

N

IN

G W

O R K

JOB NO:

DRAWING NO:

AS NOTED

REVISIONS:

S

O U

TH

P

IN

E G

R O

V E

S

TR

EE

T

FR

ED

ER

IC

KS

B U R G

PA

B

ET

H

EL

T O

W N S H

IP

LE

B A N O

N C

O U N

TY

JUNE 17, 2026

E ld on R

. S to lt zf us , A rc hi te ct

Ph on e:

(7

) 2

-5

F ax

7)

-9

E -m ai l:

es to ltz fu s@ er sa rc hi te ct .c om

Ar ch ite ct rio r D es ig n

W

IT

H O

U T

H

IS

P

ER

M

IS

SI

O

N A

N D

U N

LE

SS

T H

E R

EP

R

O D

U C

TI

O

N C

AR

R

IE

S

H

IS

N

AM

E

AS

T H

E

AR

C H

IT

EC

T

TH

IS

D

R

AW

IN

G

A S

AN

IN

ST

R

U M

EN

T

O F

SE

R

VI

C

E

IS

T H

E

PR

O

PE

R

TY

O F

TH

E

AR

C

H

IT

EC

T

AN

D

M

AY

N O

T

BE

R

EP

R O

D U

C

ED

So ut h

D ec at ur

S sb ur g, P en ns yl va ni a

B

ET

H

EL

T O

W N S H

IP

M U N

IC

IP

A L

G A R A G

E

PERMIT SUBMITTAL

A-3

EX

TE

R

IO

R E

LE

V A

TI

O

S

1ST FLR

0'-0"

EAVE HT.

16'-0"

SCALE:

A-4 1/4" = 1'-0"

WEST ELEVATION

D.S.D.S.D.S.D.S.

1'-0"

SCALE:

A-4 1/2" = 1'-0"

SECTION 1

A-5

A-5

PROVIDE DRAFTSTOPPING IN ATTIC AREA, ATTIC AREA NOT

TO EXCEED 3,000 SF.

MATERIALS SHALL BE NOT LESS THAN 1/2-INCH (12.7 MM)

GYPSUM BOARD, 3/8-INCH (9.5 MM) WOOD STRUCTURAL

PANEL, 3/8-INCH (9.5 MM) PARTICLEBOARD, 1-INCH (25-MM)

NOMINAL LUMBER, CEMENT FIBERBOARD, BATTS OR

BLANKETS OF MINERAL WOOL OR GLASS FIBER, OR OTHER

APPROVED MATERIALS ADEQUATELY SUPPORTED.

PROVIDE DRAFTSTOPPING ON ONE-SIDE OF TRUSS,

PROVIDE AN ACCESS PANEL W/ CLOSURE

1 2

SCALE:

A-4 1/2"=1'-0"

PIPE BOLLARD DETAIL

PROVIDE GROUTED

DOMED TOP ON ALL

EXTERIOR BOLLARDS

PAINTED 6"Ø RIGID

STEEL PIPE BOLLARD

FILLED WITH

CONCRETE

2" CONSTRUCTION

JOINT (TYP.)

FINISHED

GRADE OR

CONCRETE

FLOOR

SYSTEM

20"Ø

CONCRETE

BASE

COMPACT FILL

NOTE:

ADJUST DEPTH ACCORDINGLY

WHERE LOCATED OVER BUILDING

FOOTINGS

DRAWN BY: PROJECT PHASE:

SCALE: DATE:

TH

E

C O

N

TR

A C

TO

R S

H A

LL

C H

EC

K C O

N D

IT

IO

N S

IN

P

LA

C E

A N D

O B

TA

IN

O

R V

ER

IF

Y

A

LL

N

EC

ES

S A R Y

D

IM

EN

S

IO

N S

B

EF

O R E

B

EG

IN

N

IN

G W

O R K

JOB NO:

DRAWING NO:

AS NOTED

REVISIONS:

S

O U

TH

P

IN

E G

R O

V E

S

TR

EE

T

FR

ED

ER

IC

KS

B U R G

PA

B

ET

H

EL

T O

W N S H

IP

LE

B A N O

N C

O U N

TY

JUNE 8, 2026

E ld on R

. S to lt zf us , A rc hi te ct

Ph on e:

(7

) 2

-5

F ax

7)

-9

E -m ai l:

es to ltz fu s@ er sa rc hi te ct .c om

Ar ch ite ct rio r D es ig n

W

IT

H O

U T

H

IS

P

ER

M

IS

SI

O

N A

N D

U N

LE

SS

T H

E R

EP

R

O D

U C

TI

O

N C

AR

R

IE

S

H

IS

N

AM

E

AS

T H

E

AR

C H

IT

EC

T

TH

IS

D

R

AW

IN

G

A S

AN

IN

ST

R

U M

EN

T

O F

SE

R

VI

C

E

IS

T H

E

PR

O

PE

R

TY

O F

TH

E

AR

C

H

IT

EC

T

AN

D

M

AY

N O

T

BE

R

EP

R O

D U

C

ED

So ut h

D ec at ur

S sb ur g, P en ns yl va ni a

B

ET

H

EL

T O

W N S H

IP

M U N

IC

IP

A L

G A R A G

E

PERMIT SUBMITTAL

A-4

EX

TE

R

IO

R E

LE

V A

TI

O N S

S

EC

TI

O

SCALE:

A-5 1/2" = 1'-0"

WALL SECTION @ OVERHEAD DOOR

2x6

EXP. JOINT

SLOPE MIN. 1/8"/ FT.

FIRE BLOCK GAP

AT HEADER IF REQ'D

2x6 FASCIA

VENTED SOFFIT

6'-0" APRON:

6" THICK CONCRETE SLAB

W/ WWF 6x6 W1.4xW1.4

GRADE

6" THICK CONCRETE SLAB W/

WWF 6x6 W1.4xW1.4

VAPOR BARRIER AND

6" CRUSHED STONE BASE

PRE-ENG. TRUSSES

@ 48" OC

28 GA. STEEL ROOFING

ON 2x4 PURLINS @ 24" OC

HURRICANE CLIPS AT OVERHEAD

DOOR HEADER ONLY

BOX GUTTER

(3) PLY 1 3/4 x 11

1/4" LVL HEADER,

OVERHEAD DOOR

SEE CONNECTION

DETAIL 5/A-5, TYP

2"x24" RIGID R-10 INSULATION

VERTICAL & HORZ.

EXP. JOINT

1" DEPRESSION AT

OVERHEAD DOORS

(SLOPED CONC SILL)

SCALE:

A-5 1/2" = 1'-0"

WALL SECTION

P/T 6x6 POSTS

2x12 MSR HEADER

BOTH SIDES OF POSTS

2x6 FASCIA

VENTED SOFFIT

PRE-ENG. TRUSSES

@ 48" OC

28 GA. STEEL ROOFING

ON 2x4 PURLINS @ 24" OC

24x12" CONC FOOTING

W/ (3) #6 CONT. BARS

& #6 TIES @ 32" OC

2x4 WALL GIRTS @

24" OC MAX, TYP

6" THICK CONCRETE SLAB W/

WWF 6x6 W1.4xW1.4

VAPOR BARRIER AND

6" CRUSHED STONE BASE

HURRICANE CLIPS

BOX GUTTER

GRADE

METAL LINER PANELS

METAL LINER PANELS

FLASHING

2x4 WALL GIRTS @

24" OC MAX, TYP

2x6 FIRE BLOCKING, TYP

2x4 VERT. FIRE

BLOCKING BETWEEN

GIRTS, NAILED TO

FACE OF EACH

POST, TYP

R-38 CEILING

INSULATION

MIN R-21 BATT

INSULATION

(CAVITY)

1'-6"

2x6x±18" TRUSS TIE

DOWN BLOCK, SEE ALSO

DETAIL 3/A-5

(ATTACHMENT BETWEEN

TRUSSES,

TRUSS ATTACHED TO

EACH POST)

28 GA. STEEL SIDING (ABM)

OVER BUILDING PAPER

VAPOR BARRIER

STURDI-WALL

SWP66 POST BASE

CONNECTOR

1 1/2" SPRAY FOAM

INSULATION OVER

CONCRETE WALL

(BETWEEN 2x4

WOOD FURRING)

M

IN

2"x24" RIGID R-10 INSULATION

VERTICAL & HORZ.

8" THICK x 4'-0" HIGH

POURED CONC WALL W/ #6

VERT. BARS HOOKED INTO

FOOTING & #6 HORZ. BARS @

24" OC

TRUSSES @ 48" O/C

ATTACHED TO POST

W/ (6) 12D NAILS

2 X 6 BLOCKING BETWEEN TRUSSES (TYP)

AND EACH HEADER W/ (3) 12D NAILS

2 X 12 MSR

HEADERS 2X6 FIRE BLOCKING

BETWEEN HEADERS

1/2" (TYP)

/4

E

Q S

P A

/4

"0.131 x 3 1/4 Gun Nail (Typ)

2x12 Header

2x4 SYP Block

/4

E

Q S

P A =1

/4

/4

E

Q S

P A

/4

/4

E

Q S

P A =1

/4

8'-0"

ATTACH TO TRUSS W/ (6) 12D NAILS

6 X 6

POST

6 X 6 POST

SCALE:

A-5 N.T.S.

2x12 HEADER CONNECTION DETAIL

SCALE:

A-5 N.T.S.

TRUSS TIE DETAIL

0.131X11 1/4

GUN NAIL (TYP)

2X12 HEADER

2x4 SYP Block

/4

E

Q S

P A =7

/2

/4

LSTA18 BOTH

SIDES

H10A ON DOOR

HEADERS ONLY

SCALE:

A-5 N.T.S.

O/H DOOR HEADER CONNECTION DETAIL

6 X 6 POST

(3) PLY 1 3/4

x 11 1/4" LVL

HEADER

WEATHER STRIPPING

OVERHEAD DOOR

& TRACK

CONT. 2x6 FOR O.H.

DOOR SUPPORT

3 1/2" x 5/4 BORAL

TRIM PAINTED

10 1/2" x 5/4 BORAL

TRIM PAINTED

6x6 POST

2x4 WALL GIRTS

R-21 INSULATION

METAL SIDING &

'J' CHANNEL

METAL LINER PANEL

& 'J' CHANNEL

SCALE:

J1 A-5 1/" = 1'-0"

OVERHEAD DOOR

JAMB DETAIL

BUILDING PAPER

SCALE:

H1 A-5 1/" = 1'-0"

OVERHEAD DOOR

HEAD DETAIL

METAL SIDING &

'J' CHANNEL

BUILDING PAPER

2x4 WALL GIRTS

R-21 INSULATION

(2) 2x6

2x10 VERT. FOR

DOOR TRACK

SUPPORT

10 1/2" x 5/4 BORAL

TRIM PAINTED

3 1/2" x 5/4 BORAL

TRIM PAINTED

2x6

WEATHER STRIPPING

SCALE:

H2 A-5 1/" = 1'-0"

MAN DOOR

HEAD DETAIL

METAL SIDING &

'J' CHANNEL

BUILDING PAPER

2x4 WALL GIRTS

R-21 INSULATION

3 1/2" x 5/4 BORAL

TRIM PAINTED

METAL FRAME

& 2x6

CAULK

METAL LINER

PANEL & 'J'

CHANNEL

DBL. 2x6 HEADER

METAL FLASHING

SCALE:

J2 A-5 1/" = 1'-0"

MAN DOOR

JAMB DETAIL

2"

1 2

CAULK

3 1/2" x 5/4 BORAL

TRIM PAINTED

METAL SIDING &

'J' CHANNEL

3 1/2" x 5/4 BORAL

TRIM PAINTED

3 1/2" x 5/4

BORAL TRIM

PAINTED

5/4 BORAL

TRIM PAINTED

5/4 BORAL

TRIM PAINTED

2x6 JACK &

KING STUD

2x4 WALL

GIRTS

METAL LINER

PANEL & 'J'

CHANNEL

METAL FRAME

& 2x6

8"

DRAWN BY: PROJECT PHASE:

SCALE: DATE:

TH

E

C O

N

TR

A C

TO

R S

H A

LL

C H

EC

K C O

N D

IT

IO

N S

IN

P

LA

C E

A N D

O B

TA

IN

O

R V

ER

IF

Y

A

LL

N

EC

ES

S A R Y

D

IM

EN

S

IO

N S

B

EF

O R E

B

EG

IN

N

IN

G W

O R K

JOB NO:

DRAWING NO:

AS NOTED

REVISIONS:

S O

U

TH

P

IN

E G

R O

V E

S

TR

EE

T

FR

ED

ER

IC

KS

B U R G

PA

B

ET

H

EL

T O

W N S H

IP

LE

B A N O

N C

O U N

TY

JUNE 8, 2026

E ld on R

. S to lt zf us , A rc hi te ct

Ph on e:

(7

) 2

-5

F ax

7)

-9

E -m ai l:

es to ltz fu s@ er sa rc hi te ct .c om

Ar ch ite ct rio r D es ig n

W

IT

H O

U T

H

IS

P

ER

M

IS

SI

O

N A

N D

U N

LE

SS

T H

E R

EP

R

O D

U C

TI

O

N C

AR

R

IE

S

H

IS

N

AM

E

AS

T H

E

AR

C H

IT

EC

T

TH

IS

D

R

AW

IN

G

A S

AN

IN

ST

R

U M

EN

T

O F

SE

R

VI

C

E

IS

T H

E

PR

O

PE

R

TY

O F

TH

E

AR

C

H

IT

EC

T

AN

D

M

AY

N O

T

BE

R

EP

R O

D U

C

ED

So ut h

D ec at ur

S sb ur g, P en ns yl va ni a

B

ET

H

EL

T O

W N S H

IP

M U N

IC

IP

A L

G A R A G

E

PERMIT SUBMITTAL

A-5

W A

LL

S

EC

TI

O

DRAWN BY: PROJECT PHASE:

SCALE: DATE:

TH

E

C O

N

TR

A C

TO

R S

H A

LL

C H

EC

K C O

N D

IT

IO

N S

IN

P

LA

C E

A N D

O B

TA

IN

O

R V

ER

IF

Y

A

LL

N

EC

ES

S A R Y

D

IM

EN

S

IO

N S

B

EF

O R E

B

EG

IN

N

IN

G W

O R K

JOB NO:

DRAWING NO:

AS NOTED

REVISIONS:

S O

U

TH

P

IN

E G

R O

V E

S

TR

EE

T

FR

ED

ER

IC

KS

B U R G

PA

B

ET

H

EL

T O

W N S H

IP

LE

B A N O

N C

O U N

TY

JUNE 11, 2026

E ld on R

. S to lt zf us , A rc hi te ct

Ph on e:

(7

) 2

-5

F ax

7)

-9

E -m ai l:

es to ltz fu s@ er sa rc hi te ct .c om

Ar ch ite ct rio r D es ig n

W

IT

H O

U T

H

IS

P

ER

M

IS

SI

O

N A

N D

U N

LE

SS

T H

E R

EP

R

O D

U C

TI

O

N C

AR

R

IE

S

H

IS

N

AM

E

AS

T H

E

AR

C H

IT

EC

T

TH

IS

D

R

AW

IN

G

A S

AN

IN

ST

R

U M

EN

T

O F

SE

R

VI

C

E

IS

T H

E

PR

O

PE

R

TY

O F

TH

E

AR

C

H

IT

EC

T

AN

D

M

AY

N O

T

BE

R

EP

R O

D U

C

ED

So ut h

D ec at ur

S sb ur g, P en ns yl va ni a

B

ET

H

EL

T O

W N S H

IP

M U N

IC

IP

A L

G A R A G

E

PERMIT SUBMITTAL

A-6

S

PE

C

IF

IC

A

TI

O

SCALE:

MEP 1/4" = 1'-0"

MECHANICAL, ELECTRICAL, PLUMBING PLAN

'x

' O

.H D

O O

R

'x

' O .H

D

O O

R

14'x14' O.H. DOOR 14'x14' O.H. DOOR 14'x14' O.H. DOOR

6'-0" CONCRETE APRON

C O

N C R

E T E A

P R

O N

RACK SYSTEM RACK SYSTEM

RACK SYSTEM

D.S.D.S.D.S.D.S.

D.S. D.S. D.S. D.S.

STORAGE GARAGE

METAL LINER

CEILING FINISH

16'-0" HEIGHT

FE

FE

WATER HYDRANT/HOSE BIBB.

PROVIDE SHUT OFF VALVE ON

WATER LINE PRIOR TO FAUCET

WATER SUPPLY

FROM ADJACENT

BUILDING

ELECTRIC CONDUIT

CONDUIT FOR FUTURE

NATURAL GAS LINE

(FUTURE GAS HEATER(S)

DESCRIPTIONMARK

EMERGENCY FIXTURE LEGEND

DUAL REMOTE EMERGENCY HEADS

EXIT SIGN - FACE AND DIRECTION ARROWS AS INDICATED

EXIT SIGN w/ REMOTE HEADS

EMERGENCY BATTERY UNIT

FE

20# ABC FIRE EXTINGUISHER (MIN. 2-A RATING)

TOP OF EXTINGUISHER AT 5'-0" MAX. A.F.F.

BOTTOM AT 4" MIN. A.F.F.

FE

RECESSED 20# ABC FIRE EXTINGUISHER (MIN. 2-A RATING)

TOP OF EXTINGUISHER AT 5'-0" MAX. A.F.F.

BOTTOM AT 4" MIN. A.F.F.

1. ALL EMERGENCY LIGHTS COMPLY w/ UL:94V-0

2. EMERGENCY LIGHTING TO BE CONNECTED TO LOCAL

LIGHTING CIRCUITS AHEAD OF ANY SWITCHING DEVICES.

3. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT

BE LESS THAN (1) ONE FOOTCANDLE AT THE WALKING

SURFACE

ELECTRICAL NOTES

RECEPTACLES (UNFINISHED AREAS)

LIGHTING CONTROL SWITCHES

RECEPTACLES (FINISHED AREAS)

DEVICE MOUNTING HEIGHTS

FIRE ALARM HORN/STROBE

PANEL BOARDS

TELEPHONE OUTLETS

DISCONNECT SWITCHES

FIRE ALARM STATIONS

80" AFF TO BOTT.

18" AFF TO CL

54" AFF TO BOTT.

72" AFF TO TOP

42" AFF TO CL

46" AFF TO CL

46" AFF TO CL

DISCONNECTS ON

EXTERIOR

OF BUILDING

18" AFF TO CL

· ALL ELECTRICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF 2020 N.E.C.,

ALL LOCAL CODES AND BE INSPECTED BY A REGISTERED ELECTRICAL INSPECTOR.

· COORDINATE ALL ELECTRICAL WORK WITH OTHER TRADE PERSONS TO ENSURE

PROPER CLEARANCE WITH PIPES, DUCTS, AND OPENINGS.

· COORDINATE THE EXACT MOUNTING LOCATION OF DISCONNECT SWITCHES WITH

OTHER TRADES AND PROVIDE MOUNTING HARDWARE FOR EQUIPMENT.

· STARTERS, CONTROLS AND REMOTE SWITCHES SHOW FOR EQUIPMENT FURNISHED BY

OTHER CONTRACTORS WILL BE PROVIDED WITH THE RESPECTIVE EQUIPMENT,

BUT SHALL BE CONNECTED BY THE ELECTRICAL CONTRACTOR.

· THE ELECTRICAL CONTRACTOR SHALL INSTALL A COMPLETE GROUNDING SYSTEM AS

REQUIRED BY THE N.E.C. AND THE UTILITY COMPANY INCLUDING EQUIPMENT GROUNDS.

THIS SHALL INCLUDE GROUNDING THE WATER METER.

· PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANELS AS PER N.E.C. 110.26(F) .

· ALL ELECTRICAL EQUIPMENT AMPERAGE TO BE CHECKED AND DETERMINED BY

ELECTRICAL CONTRACTOR.

· ALL FIXTURE TYPES AND LOCATIONS TO BE VERIFIED BY ELECTRICAL CONTRACTOR.

· EMERGENCY LIGHTING TO BE CONNECTED TO LOCAL LIGHTING CIRCUIT AHEAD OF

ANY SWITCHING DEVICES.

· ALL EQUIPMENT AND ELECTRICAL MATERIALS USED TO CONNECT THE EQUIPMENT,

WHERE POSSIBLE, TO BE LISTED BY A RECOGNIZED TESTING AGENCY SUCH AS U.L.

· ALL PENETRATIONS THROUGH CEILINGS & WALLS TO BE SEALED. PENETRATIONS

THROUGH FIRE RATED CEILINGS & WALLS TO BE SEALED WITH APPROVED FIRE

STOP CAULK.

· WIRING METHOD: ROMEX INTERIOR SPACES WHERE CONCEALED, EMT WHERE

EXPOSED, AND PVC UNDERGROUND.

· CONDUCTORS: COPPER CONDUCTORS SHALL BE TYPE THHN/THWN; ALUMINUM

CONDUCTORS SHALL BE XHHW. CONDUCTORS SHALL BE SIZED PER

N.E.C. 310-15A AND 310-16.

· A.I.C. REQUIREMENTS ARE NOT KNOWN AT THIS TIME. THE ELECTRICAL CONTRACTOR

SHALL VERIFY A.I.C. WITH LOCAL POWER COMPANY, AND PROVIDE ALL PANELS AND

EQUIPMENT WITH PROPER A.I.C. RATINGS.

· ALL LIGHTING CONTROLS TO COMPLY WITH 2021 IECC SECTION C405.2

DESCRIPTIONMARK

ELECTRICAL LEGEND

S

3S

4S

DS

NOTE: NOT ALL SYMBOLS USED IN ALL DRAWINGS

EF

OS

OS

PC

SPECIAL PURPOSE RECEPTACLE

GROUND FAULT CIRCUIT INTERRUPTER

CIRCUIT HOME RUN

EXHAUST FAN

DIMMER SWITCH

JUNCTION BOX

LED HIGH BAY SHOP LIGHT

DUPLEX RECEPTACLE

DOUBLE DUPLEX RECEPTACLE

SINGLE POLE SWITCH

3 WAY SWITCH

4 WAY SWITCH

DISCONNECT/SAFETY SWITCH

PANELBOARD / LOADCENTER

OCCUPANCY SENSOR SWITCH

CEILING OCCUPANCY SENSOR

PHOTOCELL SENSOR

CEILING MOUNTED LIGHTING FIXTURE

WALL MOUNTED LIGHTING FIXTURE

WALL PACK LIGHT FIXTURE

J

WP

MOTOR

WP

GFI

6'-7" MAXIMUM TO THE

UPPERMOST LEVEL

OF THE OPERATING

HANDLE

WEATHER RESISTANT OUTLET &

WEATHER PROOF COVER

NOTE:

UTILITIES FROM ADJACENT

BUILDING ON SITE

ELECTRIC

PANEL

W P

WP

WP

W P

PC

TO ALL WALL

PACK LIGHTS

3S 3S

S

S

LED HIGH BAY

SHOP LIGHT.

E.C. TO VERIFY

SPACING PER

TYPE & LUMENS

±1

±12'-0"

WP

GFI

WP

GFI

WP

GFI

DRAWN BY: PROJECT PHASE:

SCALE: DATE:

TH

E

C O

N

TR

A C

TO

R S

H A

LL

C H

EC

K C O

N D

IT

IO

N S

IN

P

LA

C E

A N D

O B

TA

IN

O

R V

ER

IF

Y

A

LL

N

EC

ES

S A R Y

D

IM

EN

S

IO

N S

B

EF

O R E

B

EG

IN

N

IN

G W

O R K

JOB NO:

DRAWING NO:

AS NOTED

REVISIONS:

S O

U

TH

P

IN

E G

R O

V E

S

TR

EE

T

FR

ED

ER

IC

KS

B U R G

PA

B

ET

H

EL

T O

W N S H

IP

LE

B A N O

N C

O U N

TY

JUNE 8, 2026

E ld on R

. S to lt zf us , A rc hi te ct

Ph on e:

(7

) 2

-5

F ax

7)

-9

E -m ai l:

es to ltz fu s@ er sa rc hi te ct .c om

Ar ch ite ct rio r D es ig n

W

IT

H O

U T

H

IS

P

ER

M

IS

SI

O

N A

N D

U N

LE

SS

T H

E R

EP

R

O D

U C

TI

O

N C

AR

R

IE

S

H

IS

N

AM

E

AS

T H

E

AR

C H

IT

EC

T

TH

IS

D

R

AW

IN

G

A S

AN

IN

ST

R

U M

EN

T

O F

SE

R

VI

C

E

IS

T H

E

PR

O

PE

R

TY

O F

TH

E

AR

C

H

IT

EC

T

AN

D

M

AY

N O

T

BE

R

EP

R O

D U

C

ED

So ut h

D ec at ur

S sb ur g, P en ns yl va ni a

B

ET

H

EL

T O

W N S H

IP

M U N

IC

IP

A L

G A R A G

E

PERMIT SUBMITTAL

MEP

M

EC

H A N

IC

A L, E

LE

C

TR

IC

A L, P

LU

M B

IN

G P

LA

Sheets and Views
CS
Sheets and Views
A-1
Sheets and Views
A-1
Sheets and Views
A-1
Sheets and Views
A-1
Sheets and Views
A-1
Sheets and Views
A-1
Sheets and Views
A-1

File details come from the government source that posted it. Updated .