2-26-278 IFB Courthouse Sheets - Posted.pdf
PDF 10 MB Posted
- Attached to
- Bank Building Renovation & Courthouse Restrooms
- Solicitation number
- 26-278
- Issued by
- Harford County, Maryland
About this file
Bank Building Renovation & Courthouse Restrooms Project
This is a project specification and construction document set for Harford County, Maryland's Bank Building Renovation & Courthouse Restrooms project, involving the Harford County Department of Public Works - Capital Works and located at 12 Office Street (M&T Bank renovation) and 20 West Courtland Street (Circuit Courthouse). The project encompasses renovation of an existing bank building for the State's Attorney Office and the addition of two single-occupancy, staff restrooms on the first floor of the Circuit Courthouse. This is classified as a Level 2 Alteration under the International Existing Building Code, affecting less than 1% of the 92,400 square foot building (150 square feet of work area). The scope includes demolition of existing office space, construction of new partition walls, installation of plumbing and HVAC systems, flooring, wall finishes, doors, hardware, electrical connections, and accessible restroom fixtures. The project incorporates ADA compliance requirements, fire-rated assembly construction, and coordination with existing building systems. Permit/bid/construction submission date is 08/28/2026.
The construction documents include comprehensive architectural, mechanical, plumbing, and electrical drawings prepared by Manns Woodward Studios (Architect), with structural engineering by Morabito Consultants, MEP engineering by BKM, and dated through April 22, 2026 (Revision B). Project compliance is required under the 2021 International Building Code, 2021 International Existing Building Code, 2021 International Energy Conservation Code, State of Maryland Fire Prevention Code, Maryland Accessibility Code, 2023 National Electric Code, and 2021 International Plumbing Code. The project specifies finishes including ceramic tile flooring and base, wall tile, gypsum wall board ceilings, accessible grab bars, mirrors, dispensers, and stainless steel grab bars per Bobrick specifications. Specific mechanical requirements include new exhaust fans, ductwork connections to existing risers, and plumbing fixtures including wall-mounted lavatories, floor-mounted water closets with flush valves, and floor drains with trap priming lines. The contractor is responsible for all demolition, existing condition verification, temporary bracing and support, site coordination with occupied courthouse operations, utility outages (minimum 72-hour notice), and maintaining HVAC service to unaffected areas during construction phasing.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-26-278 IFB - Posted.pdf | ||
| 4-26-278 IFB Bank Building Sheets - Posted.pdf | ||
| 3-26-278 IFB Technical Specifications - Posted.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
PROJECT LOCATION
SYMBOLS
& - AND
@ - AT
- DIAMETER
- SQUARE
A
AB - ANCHOR BOLT
ABV - ABOVE
ACOUST - ACOUSTICAL
ACT - ACOUSTIC CEILING TILE
AFF - ABOVE FINISH FLOOR
AHJ - AUTHORITY HAVING
JURISDICTION
ALUM - ALUMINUM
AP - ACCESS PANEL
APPROX - APPROXIMATELY
ARCH - ARCHITECTURAL
B
B.C. - BOTTOM CHORD
BLK - BLOCK
BLDG - BUILDING
BLKG - BLOCKING
BLKHD - BULKHEAD
BM - BEAM
B.O. - BOTTOM OF
BOD - BASIS OF DESIGN
BOT - BOTTOM
B.R. - BULLET RESISTANT
BRNG - BEARING
C
C - CENTER LINE
CFCI - CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CFOI - CONTRACTOR FURNISHED,
OWNER INSTALLED
CFLS - COUNTER FLASHING
CJ - CONTROL JOINT
CL - CLOSET
CLG - CEILING
CMU - CONCRETE MASONRY UNIT
CND - CONDUIT
COL. - COLUMN
COOR - COORDINATE
CONC - CONCRETE
CONSTR - CONSTRUCTION
CONT - CONTINUOUS
C.T. / CT - CERAMIC TILE
CPT - CARPET / CARPET TILE
CTSK - COUNTERSUNK
CU - CUBIC
CU FT - CUBIC FOOT
CU YD - CUBIC YARD
D
D - DEEP / DEPTH
DEG - DEGREE
DIA - DIAMETER
DIM - DIMENSION
DL - DEAD LOAD
DMPR - DAMPER
DN - DOWN
DR - DOOR
DS - DOWNSPOUT
DTL - DETAIL
DWG - DRAWING
E
EA - EACH
EIFS - EXTERIOR INSULATON AND
FINISHING SYSTEM
ELEC - ELECTRICAL
EL - ELEVATION
ELEV - ELEVATION
ELMA - ELEVATOR MACHINE ROOM
EJ - EXPANSION JOINT
ENT - ENTRANCE, ENTRY
EQ - EQUAL
EST - ESTIMATE
ETR - EXISTING TO REMAIN
EW - EACH WAY
EXST - EXISTING
EXT - EXTERIOR
EXP - EXPOSED
EXP JT - EXPANSION JOINT
F
F - FAHRENHEIT
FD - FLOOR DRAIN
F.E. - FIRE EXTINGUISHER
F.E.C. - FIRE EXTINGUISHER CABINET
FF - FINISHED FLOOR
FF EL - FINISHED FLOOR ELEVATION
FG - FINISHED GRADE
FHY - FIRE HYDRANT
FDC - FIRE DEPARTMENT
CONNECTION
FIN - FINISH
FIN FL - FINISHED FLOOR
FL - FLOOR
FLEX - FLEXIBLE
FLUOR - FLUORESCENT
FND - FOUNDATION
FPM - FEET PER MINUTE
FRT - FIRE RETARDANT
TREATED
FSK - FOIL SCRIM KRAFT
FT - FEET, FOOT
FT - FLOOR TRANSITION
FTG - FOOTING
G
GA - GAGE, GAUGE
GALV - GALVANIZED
GL - GLASS, GLAZING
GND - GROUND
GRTG - GRATING
GWB - GYPSUM WALL BOARD
H
H - HIGH / HEIGHT
HC - HANDICAPPED
HD - HEAD
HM - HOLLOW METAL
HORIZ - HORIZONTAL
HR - HOUR
HT - HEIGHT
I
ID - INSIDE DIAMETER
IN - INCH
INFO - INFORMATION
INSUL - INSULATION
J
JB - JUNCTION BOX
JM - JAMB
JST - JOIST
JT - JOINT
L
LG - LONG
LL - LIVE LOAD
LSC - LIFE SAFETY CODE
LTG - LIGHTING
M
MACH - MACHINE
MAT'L - MATERIAL
MAX - MAXIMUM
MBT - MARBLE THRESHOLD
MECH - MECH
MEP - MECHANICAL /
ELECTRICAL /
PLUMBING
MFGR - MANUFACTURER
MH - MANHOLE
MIN - MINIMUM
MO - MASONRY OPENING
MSNRY - MASONRY
M.T. - METAL THRESHOLD
MTL - METAL
MTD - MOUNTED
N
NA - NOT APPLICABLE
NIC - NOT IN CONTRACT
NO - NUMBER
NTS - NOT TO SCALE
O
O/C - ON CENTER
OD - OUTSIDE DIAMETER
OFCI - OWNER FURNISHED,
CONTRACTOR INSTALLED
OFOI - OWNER FURNISHED,
OWNER INSTALLED
OPNG - OPENING
OPP - OPPOSITE
OPP HND - OPPOSITE HAND
OV - OVER
OVHD - OVERHEAD
P
P.LAM - PLASTIC LAMINATE
PLY - PLYWOOD
PLYWD - PLYWOOD
PNLBD - PANELBOARD
PNT/ PT - PAINT
POLYISO - POLYISOCYANURATE
PRESS - PRESSURE
PROJ - PROJECT
PROP - PROPERTY
PSF - POUNDS PER SQUARE FOOT
PSI - POUNDS PER SQUARE INCH
PT - PRESSURE TREATED
PTD - PAINTED
PVC - POLYVINYL CHLORIDE
PVMT - PAVEMENT
PWT - PREFABRICATED WOOD
TRUSS
R
R - RADIUS
RCP - REFLECTED CEILING PLAN
REINF - REINFORCING,
REINFORCED
RES - RESINOUS
REQD - REQUIRED
REV - REVISION
RGD - RIGID
RM - ROOM
RO - ROUGH OPENING
RST - REINFORCING STEEL
S
SB - SMART BOARD
SCHED - SCHEDULE
SD - STORM DRAIN
SECT - SECTION
SF - SQUARE FOOT
SI - SQUARE INCH
SIM - SIMILAR
SLP - SLOPE
SPCL - SPECIAL
SPEC - SPECIFICATIONS
SPLY - SUPPLY
SQ - SQUARE
SS - STAINLESS STEEL
ST - STREET
STD - STANDARD
STL - STEEL
STOR - STORAGE
STRUCT - STRUCTURAL
SURF - SURFACE
SUSP - SUSPENDED
SW - SWITCH
SYS - SYSTEM
T
T & B - TOP AND BOTTOM
T.B. - TACK BOARD
T.B.D. - TO BE DETERMINED
TEMP - TEMPERATURE
THK - THICK
THRES - THRESHOLD
T&G - TONGUE & GROOVE
T0 - TOP OF
TOB - TOP OF BEARING POINT
TOC - TOP OF CONCRETE
TOF - TOP OF FOOTING
TOM - TOP OF MASONRY
TOP - TOP OF PAVEMENT, PARAPET
TOS - TOP OF STEEL
TRTD - TREATED
T.S. - TRANSITION STRIP
TYP - TYPICAL
U
UGND - UNDERGROUND
UL - UNDERWRITERS LAB
UNO - UNLESS NOTED OTHERWISE
UON - UNLESS OTHERWISE NOTED
V
VB - VAPOR BARRIER
VCT - VINYL COMPOSITION TILE
VERT - VERTICAL
VIF - VERIFY IN FIELD
VOL - VOLUME
W
W - WIDE / WIDTH
W/ - WITH
W/0 - WITHOUT
W.B. - WHITEBOARD
WD - WOOD
WR - WATER RESISTANT
WTRPRF - WATERPROOF
WWF - WELDED WIRE FABRIC
WWM - WELDED WIRE MESH
L
THIS LIST OF ABBREVIATIONS IS A GUIDE TO ABBREVIATIONS WHICH MAY BE USED IN THESE DOCUMENTS.
ABBREVIATIONS NOT LISTED MAY ALSO BE USED.
COMMON ABBREVIATIONS
CORRELATION AND INTENT OF THE
CONTRACT DOCUMENTS
THE INTENT OF THE CONSTRUCTION DRAWINGS AND THE CONSTRUCTION SPECIFICATIONS/PROJECT MANUAL IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE
WORK BY THE CONTRACTOR. THE CONSTRUCTION DRAWINGS AND THE CONSTRUCTION
SPECIFICATIONS/PROJECT MANUAL ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL; PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE
EXTENT CONSISTENT WITH THE CONSTRUCTION DRAWINGS AND THE CONSTRUCTION
SPECIFICATIONS/PROJECT MANUAL AND REASONABLY INFERABLE FROM THEM AS BEING NECESSARY TO PRODUCE THE INDICATED/INTENDED RESULTS. IN THE CASE OF INCONSISTENCIES BETWEEN THE CONSTRUCTION DRAWINGS AND THE CONSTRUCTION SPECIFICATIONS/PROJECT MANUAL OR WITHIN EITHER DOCUMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE
PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION.
SECTION PATTERN
BRICK
CMU MASONRY
CONCRETE
POROUS FILL
PLYWOOD
RIGID INSULATION
BATT INSULATION
DESCRIPTION
EARTH
GYPSUM BOARD
END GRAIN LUMBER
WOOD BLOCK OR SHIM
FINISH WOOD
KEY TO MATERIALS
ARCHITECT
MANNS WOODWARD STUDIOS
10839-D PHILADELPHIA ROAD
WHITE MARSH MARYLAND 21162
PHONE: 410-344-1460
FAX: 443-403-2460
PROJECT TEAM
STRUCTURAL ENGINEER
MORABITO CONSULTANTS
652 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
CONTACT: DANA ELLEBERGER, PE
PHONE: 410-773-0244 (DIRECT)
MEP ENGINEER
BKM
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
CONTACT: IAN SWEENEY, PE
PHONE: 443-632-1252 (DIRECT)
E-MAIL: ISWEENEY@BKMA.COM
OWNER
HARFORD COUNTY
DPW - CAPITAL WORKS
220 S MAIN STREET
BEL AIR, MD 21014
CIVIL ENGINEER
SPECIALITY CONSULTANT
EQ-XX SPECIALTY EQUIPMENT TAG
COLUMN LINE
DESIGNATION
TAG
LEVEL ELEVATION TAG
NORTH ARROW TAG
ROOM NAME &
NUMBER TAG
DETAIL / DRAWING
TITLE TAG
PARTITION TAG
WINDOW TAG
SLOPE ANNOTATION
SPOT ELEVATION TAG
SECTION TAG
CALLOUT / DETAIL
00.0
ELEVATION TAG
0'-0"
1t
1 A
A101
A101
SPECIFIC NOTE
P
DRAWING TITLE
DRAWING SCALE
0'-0"
REFERENCE
A101
MATERIAL TAG
T = TRUE NORTH
P = PROJECT NORTH
T
TAG
DOOR TAG
30.00 24.00 84.00
CASEWORK TAG
DESCRIPTION
CABINET DEPTH
CABINET HEIGHTCABINET
WIDTH
NUMBER OF
SHELVES
AS OUTLINED IN THE ARCHITECTURAL
WOODWORK INSTITUTE (AWI)
STANDARDS
CASEWORK
SERIES
ROOM
DEMOLITION
NEW
CONSTRUCTION
SYMBOLS & TAGS LEGEND
CLG-12
1'-0"
CEILING TAG
TYPE
HEIGHT
U 100A
MINIMUM CLEAR CABINET DEPTH
DIMENSION = DEPTH LESS 1"
HARFORD COUNTY, MD
26-278 BANK BUILDING RENOVATION & COURTHOUSE RESTROOMS
20 WEST COURTLAND STREET, BEL AIR, MD 21014
PERMIT/BID/CONSTRUCTION 08/28/2026
NOT TO SCALE
VICINITY MAP
DRAWING INDEX
SHEET
NUMBER SHEET NAME
GENERAL / CODE
V2-G000 COVER SHEET
V2-G001 CODE ANALYSIS & DIAGRAM
V2-G010 TYPICAL ACCESSIBILITY GUIDELINES
OVERALL INFORMATION
V2-A001 OVERALL INFORMATION
ARCHITECTURAL
V2-A101 FLOOR PLANS
V2-A103 ENLARGED PLANS, FINISHES & INT. ELEVATIONS
V2-A600 DOOR AND SIGNAGE INFORMATION
V2-A800 RCPS, CEILING TYPES, & NOTES
MECHANICAL
V2-M001 MECHANICAL LEGEND, ABBREVIATIONS & GENERAL
NOTES
V2-M101 FIRST FLOOR DUCTWORK PLAN - NEW WORK
V2-M201 MECHANICAL DETAILS AND SCHEDULES
PLUMBING
V2-P001 PLUMBING LEGEND, ABBREVIATIONS & GENERAL NOTES
V2-P101 FIRST FLOOR PLUMBING PLAN - NEW WORK
V2-P201 PLUMBING DETAILS AND SCHEDULES
ELECTRICAL
V2-E001 ELECTRICAL LEGEND, ABBREVIATIONS, GENERAL NOTES
V2-E101 FIRST FLOOR PLAN ELECTRICAL - NEW WORK
SHEET NUMBER:
ORIGINAL ISSUE DATE:
SHEET REVISION SCHEDULE:
SUBMISSION:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
DULY LICENSED PROFESSIONAL ARCHITECT UNDER
THE LAWS OF THE STATE OF MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
SEAL:
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
S T U D I O S
8098 SANDPIPER CIR, SUITE H
NOTTINGHAM, MD 21236
ARCHITECTURE + INTERIOR DESIGN
CONSULTANT:
9/ /2 9:
:2
AM
LAST PROJECT REVISION: No B | 04/22/26
V2-G000
COVER SHEET
08/28/2026
PROJECT NUMBER: 23-194
PERMIT/BID/CONSTRUCTION
H A
RF
O
RD
C O U N
TY
M D
-2 B A N K B U
IL
D
IN
G R
EN
O V A
TI
O N
C O U
RT
H O U
SE
R
ES
TR
O O M S
W
ES
T C O U
RT
LA
N D S
TR
EE
T, B
EL
A
IR
M D
REVISION SCHEDULE
No. DATE DESCRIPTION
A 04/09/26 PERMIT COMMENT RESPOINSES
B 04/22/26 PERMIT COMMENTS
No. DATE A 04/09/26 B 04/22/26
Reviewed For Code Compliance
These plans have been reviewed for code compliance to the applicable provisions of Chapter 82 of the Harford County Code and, when applicable, the Maryland Accessibility Code. Harford County Code is currently based on the 2021 versions of the IBC, IRC and IECC.
Electric, mechanical and plumbing reviews have not been performed at this time.
The approval of these plans shall not grant authority to violate any state or local laws. Construction must be in accordance with approved plans or approved amendments thereto. All agency comments should be reviewed and understood prior to commencing work.
Approved By; Cody J. Davis, Senior Plans Examiner 04/27/2026
UP
DN
AREA NOT IN SCOPE
EXISTING
EXIT STAIR
EXISTING
EXIT STAIR
EXIT
EXIT
AREA NOT IN SCOPE
DE-1
DEAD
END
DE-2
DEAD
END
ASSUMEDASSUMED2 HR2 HR
EXISTING MASONRYEXISTING MASONRY
ASSUMEDASSUMED2 HR2 HR
EXISTING MASONRYEXISTING MASONRY
90MIN.
90MIN.
CODE ANALYSISCODE ANALYSIS - SUMMARY
PROJECTPROJECT
HARFORD COUNTY
CIRCUIT COURTHOUSE
RESTROOM RENOVATION
PROJECT DESCRIPTIONPROJECT DESCRIPTION
THIS PROJECT IS A RENOVATION TO THE EXISTING COURTHOUSE. THE PROPOSED PROJECT IS TO ADD TO SINGLE USER STAFF RESTROOMS ON THE 1ST FLOOR/MAIN LEVEL. THE RESTROOMS WILL OVERTAKE PORTIONS OF CURRENTLY OCCUPIED OFFICE SPACE.
THIS PROJECT IS A LEVEL 2 ALTERATION PER THE EXISTING BUILDING CODE CONSISTING OF AN ALTERATION TO THE EXISTING SPACE THAT IS LESS THAN 50% OF THE EXISTING BUILDING. THE EXISTING BUILDING’S USE, OCCUPANCIES, AND LEVEL OF FIRE
SAFETY/EGRESSING WILL REMAIN AS IT EXISTS.
THE EXISTING COURTHOUSE IS UN-SPRINKLERED
EXISTING COURTHOUSE HAS A FIRE ALARM
APPLICABLE CODESAPPLICABLE CODES
2021 International Building Code 2021 International Mechanical Code 2021 International Existing Building Code 2021 International Energy Conservation Code State of Maryland Fire Prevention Code, COMAR 29.06.01
2024 NFPA 101
Maryland Building Rehabilitation Code COMAR 09.12.58 COMAR .09.12.53 Maryland Accessibility Code 2023 National Electric Code 2021 International Plumbing Code 2021 International Fuel Gas Code
SQUARE FOOTAGESQUARE FOOTAGE
TOTAL EXISTING BUILDING = 92,400 SF
3RD FLOOR: 19,400 SF
2ND FLOOR: 19,400 SF
1ST FLOOR: 19,400 SF
BASEMENT LEVEL A: 13,000 SF
BASEMENT LEVEL B: 10,600 SF
BASEMENT LEVEL C: 10,600 SF
WORK AREA: 150 SF WHICH IS LESS THAN 1%
OF BUILDING SF
COMPLIANCE METHOD - IEBC 601COMPLIANCE METHOD - IEBC 601
LEVEL 2 ALTERATION - THIS ALTERATION IS LESS THAN 50% OF THE BUILDING AREA.
603.1 - SHALL COMPLY WITH CHAPTERS 7 & 8.
BUILDING ELEMENTS & MATERIALS - IEBC 702BUILDING ELEMENTS & MATERIALS - IEBC 702
ALL NEW WORK WILL COMPLY WITH THE REQUIREMENTS OF
THE APPLICABLE CODES NOTED ABOVE
ENERGY CONSERVATION - IEBC 707/809ENERGY CONSERVATION - IEBC 707/809
ALTERATIONS SHALL CONFORM TO THE NEW CONSTRUCTION
CODE REQUIREMENTS.
ALL NEW CONSTRUCTION WILL COMPLY WITH THE
REQUIREMENTS OF THE IBC WITH EXCEPTIONS THAT NEWLY
INSTALLED ELECTRICAL EQUIPMENT SHALL COMPLY WITH NFPA
70, DEAD END CORRIDORS SHALL COMPLY WITH IEBC 805.6, AND
THE MIN. CEILING HEIGHT SHALL BE 7'-0".
COMPLIANCE - IEBC 801.4COMPLIANCE - IEBC 801.4
USE GROUP: B – BUSINESS (UNCHANGED)
CONST. TYPE: II-B (UNCHANGED)
SPRINKLER: NO (UNCHANGED)
FIRE ALARM: YES (UNCHANGED)
EXISTING INFORMATIONEXISTING INFORMATION
GENERAL CODE PLAN NOTES
1 FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND
SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE
PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND
PERMANENTLY IDENTIFIED AS REQUIRED BY IBC 703.7
1/16" = 1'-0"1 CODE PLAN
SHEET NUMBER:
ORIGINAL ISSUE DATE:
SHEET REVISION SCHEDULE:
SUBMISSION:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
SEAL:
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
S T U D I O S
8098 SANDPIPER CIR, SUITE H
NOTTINGHAM, MD 21236
/2 9:
:2
AM
LAST PROJECT REVISION: No B | 04/22/26
V2-G001
CODE ANALYSIS & DIAGRAM
08/28/2026
PROJECT NUMBER: 23-194
PERMIT/BID/CONSTRUCTION
H A
RF
O
RD
C
O U
N
TY
M
D
-2
B A
N K
B U
IL
D
IN
G
R
EN
O V
A
TI
O N
C
O U
RT
H
O U
SE
R
ES
TR
O O
M S
W
ES
T C
O U
RT
LA
N D
S
TR
EE
T, B
EL
A
IR
M
D
CODE DISTANCES
PATH ID LENGTH
DEAD END
DE-1 19'-0"
DE-2 19'-0"
P T
No. DATE A 04/09/26 B 04/22/26
" M
IN
18" MIN.
PULL SIDE
" M
IN
PUSH SIDE
NOTE: x = 12" IF DOOR HAS BOTH A CLOSER AND LATCH.
(a)
Front Approaches - Swinging Doors
PULL SIDE
" M
IN
PUSH SIDE
NOTE: y = 48" MINIMUM IF DOOR HAS BOTH A CLOSER AND LATCH.(b)
Hinge Side Approaches - Swinging Doors
X Y
NOTE: X = 36" MIN IF Y = 60"
S = 42" MIN IF Y = 54"
Y
" M
IN
24" MIN.
PULL SIDE
" M
IN
PUSH SIDE
NOTE: y = 48" MINIMUM IF DOOR HAS CLOSER.
X
(c) Latch Side Approaches - Swinging Doors
X
Y
NOTE: y = 54" MINIMUM IF DOOR HAS CLOSER
24" MIN.
Y
48" MIN. 48" MIN.
Two Hinged Doors in Series
22" MIN.
X
48" MIN
(d) Doorways without Doors
" M
IN
" M
IN
22" MIN. 42
" M
IN
" M
IN
24" MIN.
Front Approach Side Approach Pocket or Hinge Approach Stop or Latch Approach
18" MIN.60
" M
IN
X
" M
IN
X
" 12" MIN.
" M
IN
X
(e) Recessed Doors and Gates
Pull Side Push Side Push Side with Closer and Latch
30" MIN.
" M
IN
CLEAR FLOOR SPACE
" M
IN
48" MIN.
FREE STANDING FOUNTAIN OR COOLER
MAX
5"
15" MIN
X
59"
60 INCH - DIAMETER SPACE
12" MIN. 36" MIN. 12" MIN.
" M
IN
" M
IN
T - SHAPED SPACE FOR 180 DEGREE TURNS
9" M
IN
17" - 19"
" M
IN
ALLOWABLE PROTRUSIONS INTO
WHEELCHAIR SPACE
" M
AX
6" MAX.
8" MIN.
36"
48" MIN.
" M
IN
back co nt ro l w al l se at w al l
" M
IN
60" MIN.
" M
IN
si de si de
27" MAX.
lav
15"-16"
22"-23"
2" M
AX
3" MAX. 14
5"
BACK CONTROL WALL
" M
IN
" M
AX
SIDE BACK (LONG) SIDE
NOTE: SHOWER HEAD AND CONTROL AREA MAY BE ON BACK (LONG) WALL (AS SHOWN)
OR ON EITHER SIDE WALL.
SS1
CR1
3" M
AX
CL
1"
6"
MAX
15"
MAX
15"
SHOWERHEAD AND
CONTROL AREA
SHOWERHEAD
AND CONTROL
AREA
GB1
18"
GB1
GB2
GB1
GB6
UPDN
PLAN EXTENSION AT BOTTOM OF RUN EXTENSION AT TOP OF RUN
12"
12" MIN. 12" MIN.
ELEVATION
" M
IN
. C
LE
AR
36" MIN. CLEAR
" M
IN
60" MIN.
UP
UP
LANDING
RAMP & LANDING
8"
X
8"
X
TR
EA
D
DE
PT
H
TR
EA
D
DE
PT
H
TREAD DEPTH
TREAD DEPTH
" M
IN
" M
AX
M
AX
MIRROR
20" X 40"
TOILET
PAPER
DISP.
LIQUID
SOAP
DISPENSER
SANITARY
NAPKIN
DISPOSAL
ELECTRIC
HAND
DRYER
PAPER
TOWEL
DISPENSER
COAT HOOK
/ ROBE
HOOK
TOWEL
BAR
4"
MIRROR -
FULL
HEIGHT
NOTE: ALL CONTROLS SHALL NOT EXTEND ABOVE 48" FOR
FRONT APPROACH & 54" FOR SIDE APPROACH. (SEE REACH
RANGE DIAGRAMS.)
NOTE: NOT ALL ITEMS SHOWN MAY BE USED IN
THIS BUILDING.
FINISH FLOOR
DRINKING
FOUNTAIN
(H.C.)
MOP
HOLDER/
SHELF
DRINKING
FOUNTAIN
RECESSED
MOUNT
BABY
CHANGING
STATION
" M
AX
3"
" M
AX
M
AX
" M
IN
48"
HIGH FORWARD REACH LIMIT (FRONT APPROACH)
48"
MAXIMUM FORWARD REACH OVER AN OBSTRUCTION
X
Y
48"
X
NOTE: WHEN X IS >20 INCHES MAX, Y SHALL BE 48 INCHES MAX
WHEN X IS 20-25 INCHES MAX, Y SHALL BE 44 INCHES MAX
" M
IN
30"
HIGH & LOW SIDE REACH LIMITS
10" MAX.
" M
AX
30"
" M
AX
SIDE REACH
FRONT APPROACH
30"
SIDE APPROACH
48"
M
AX
24" MAX
56" MIN.
" M
IN
.4" M
AX
" M
IN
4" MAX. 32" MIN.
ALTERNATE
DOOR
LOCATION
42" MIN. LATCH
APPROACH ONLY,
OTHER APPROACHES
48" MIN. 59" MIN.
W/ WALL MOUNTED W.C.
W/ FLOOR MOUNTED W.C.
56" MIN.
" M
IN
59" MIN.
W/ WALL MOUNTED W.C.
W/ FLOOR MOUNTED W.C.
36" MIN.
CLEAR
FLOOR
SPACE
STANDARD STALL STANDARD STALL ( END OF ROW)
REAR WALL OF STANDARD STALL
SIDE WALLS
" M
IN
CLEAR
FLOOR
SPACE
60" MIN.
" M
AX
" M
IN
" M
IN
9" M
IN
8" MIN. (KNEE CLEARANCE)
17" MIN. (DEPTH)
6" MAX. (TOE CLEARANCE)
" M
AX
LAVATORY CLEARANCES
17" MIN.
48" MIN.
" M
IN
. CLEAR
FLOOR
SPACE
19" MAX.
CLEAR FLOOR SPACE AT LAVATORIES
GB4
GB5
GB4
GB4
GB4
GB5
GB5
GB5
42" MIN. 12"
16" - 18"
7" - 9" CL
42" MIN. 12" MAX
" M
IN
" M
AX
M
AX
A
FF
" M
IN
9"
39" - 41"
GB1
GB1
39" - 41"
GB1 18
" M
IN
1"
GB1
GB1
6"
DISPENSER
OUTLET
LOCATION
NOT TO SCALE
DOOR CLEARANCES (TYPICAL)
NOT TO SCALE
DRINKING FOUNTAINS (TYPICAL)
NOT TO SCALE
FLOOR CLEARANCES (TYPICAL)
NOT TO SCALE
SHOWERS (TYPICAL)
NOT TO SCALE
STAIR & RAMP CLEARANCES (TYPICAL)
NOT TO SCALE
TYPICAL ACCESSIBLE MOUNTING HEIGHTS
NOT TO SCALE
REACH RANGES & APPROACHES (TYPICAL)
NOT TO SCALE
TOILET ROOM CLEARANCES (TYPICAL)
GB1
GB2
GB3
GB4
GB5
GB6
CR1
SS1
GRAB BAR - 18"
GRAB BAR - 24"
GRAB BAR - 30"
GRAB BAR - 36"
GRAB BAR - 42"
GRAB BAR - 48"
SHOWER CURTAIN ROD
FOLDING SHOWER SEAT
TAG FIXTURE/ACCESSORY
SHEET NUMBER:
ORIGINAL ISSUE DATE:
SHEET REVISION SCHEDULE:
SUBMISSION:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
SEAL:
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
S T U D I O S
8098 SANDPIPER CIR, SUITE H
NOTTINGHAM, MD 21236
/2 9:
:2
AM
LAST PROJECT REVISION: No B | 04/22/26
V2-G010
TYPICAL ACCESSIBILITY GUIDELINES
08/28/2026
PROJECT NUMBER: 23-194
PERMIT/BID/CONSTRUCTION
H A
RF
O
RD
C
O U
N
TY
M
D
-2
B A
N K
B U
IL
D
IN
G
R
EN
O V
A
TI
O N
C
O U
RT
H
O U
SE
R
ES
TR
O O
M S
W
ES
T C
O U
RT
LA
N D
S
TR
EE
T, B
EL
A
IR
M
D
No. DATE
DN
AREA NOT IN SCOPE
AREA NOT IN SCOPE
SCOPE OF WORK AREA -
NEW RESTROOM 1
SCOPE OF WORK AREA -
NEW RESTROOM 2
PARTITION TYPE DETAILS
P7
3 5/8" METAL STUD
5/8" 3 5/8" 5/8"
5/8" GWB EACH SIDE
4 7/8"
P8
6" METAL STUD
5/8" 6" 5/8"
5/8" GWB EACH SIDE
7 1/4"
P5
6" METAL STUD @ 16"
O.C.
5/8" GWB
6" 5/8"
6 5/8"
ACOUSTICAL BATT
INSULATION, SEE PLANS
FOR LOCATION
ACOUSTICAL BATT
INSULATION, SEE PLANS
FOR LOCATION
ACOUSTICAL BATT
INSULATION, SEE PLANS
FOR LOCATION
SHEET NUMBER:
ORIGINAL ISSUE DATE:
SHEET REVISION SCHEDULE:
SUBMISSION:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
SEAL:
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
S T U D I O S
8098 SANDPIPER CIR, SUITE H
NOTTINGHAM, MD 21236
/2 9:
:2
AM
LAST PROJECT REVISION: No B | 04/22/26
V2-A001
OVERALL INFORMATION
08/28/2026
PROJECT NUMBER: 23-194
PERMIT/BID/CONSTRUCTION
H A
RF
O
RD
C O U N
TY
M D
-2 B A N K B U
IL
D
IN
G R
EN
O V A
TI
O N
C O U
RT
H O U
SE
R
ES
TR
O O M S
W
ES
T C O U
RT
LA
N D S
TR
EE
T, B
EL
A
IR
M D
1/16" = 1'-0"1 KEY PLAN
GENERAL DEMOLITION NOTES
1 ALL BIDDERS SHALL MAKE THEMSELVES FAMILIAR WITH THE EXISTING PROJECT CONDITIONS PRIOR TO SUBMITTING A BID. THIS IS
INCLUSIVE OF CONDITIONS ABOVE ACCESIBLE CEILINGS TO DETERMINE WORKING CONDITIONS.
2 PRIOR TO THE PERFORMANCE OF ANY DEMOLITION WORK THE CONTRACTOR SHALL MAKE THEMSELVES FAMILIAR WITH THE
EXISTING CONDITIONS OF THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGNING, PROVIDING, INSTALLING, AND
MAINTAINING ALL TEMPORARY SUPPORT AND BRACING REQUIRED TO COMPLETE THE WORK.
3 THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS, DIMENSIONS, CONSTRUCTION ASSEMBLIES AND THE LIKE PRIOR TO FABRICATING, INSTALLING, OR PURCHASING ANY NEW WORK. DETAILS INDICATING EXISTING MATERIALS OF CONDITIONS MAY BE SHOWN WITHIN THE DOCUMENTS BUT ARE NOT INTENDED TO FULLY DEFINE EXISTING CONDITIONS.
4 DEMOLITION WORK MAY BE INDICATED THROUGHOUT THE CONTRACT DOCUMENTS. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO REVIEW ALL DOCUMENTS FOR ADDITIONAL DEMOLITION WORK.
5 IT IS THE CONTRACTORS RESPONSIBILITY TO MAINTAIN SAFE WORKING CONDITIONS THROUGHOUT THE CONSTRUCTION SITE. THE CONTRACTOR SHALL PROVIDE TEMPORARY BARRIERS AS REQUIRED TO PROTECT PERSONS AND PROPERTY AND OTHERWISE
MAINTAIN SAFE WORKING CONDITIONS.
6 THE CONTRACTOR SHALL MAINTAIN A CLEAR, CLEAN, USEABLE CONSTRUCTION SITE THROUGH DAILY CLEANUP OF WORK AREAS.
7 THE OWNER SHALL BE MAINTAINING OCCUPANCY OF THE SITE AND PORTIONS OF THE BUILDING DURING THE CONSTRUCTION
PROCESS. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER AND THE OWNER'S PERSONNEL THROUGHOUT THE CONSTRUCTION TO MINIMIZE, TO THE GREATEST EXTENT POSSIBLE, ANY DISRUPTIONS IN THE OWNER'S WORKING PROCEDURES.
THE PHASING OF THE PROJECT SHALL BE DETERMINED BY THE CONTRACTOR AND SHALL NOT BE REASON FOR ADDITIONAL FEES.
ADDITIONALLY, THE CONTRACTOR SHALL COORDINATE WITH THE OWNER A MINIMUM OF 72 HOURS PRIOR TO ANY DISRUPTION
OF SERVICES/UTILITIES REQUIRED TO COMPLETE THE WORK.
8 THE CONTRACTOR SHALL PROVIDE TEMPORARY DUST AND DEBRIS BARRIERS BETWEEN AREAS TO REMAIN IN OPERATION AND WORK AREAS. BARRIERS SHALL BE PROVIDED AT, BUT NOT LIMITED TO HVAC SUPPLY AND RETURN OPENINGS, TRANSFER VENTS, EXHAUST VENTS, AND OTHER SUCH OPENINGS. BARRIERS SHALL BE A MINIMUM OF 10 MIL PLASTIC SHEETING SECURED AND SEALED TO EXISTING CONSTRUCTION AND/OR TEMPORARY FRAMING. PLASTIC SHEETING SHALL BE OVERLAPPED A MINIMUM OF 12" AND
TAPED BOTH SIDES.
9 THE CONTRACTOR SHALL PROVIDE PROTECTION FROM THE WEATHER FOR PORTIONS OF EXISTING CONSTRUCTION THAT ARE TO REMAIN OCCUPIED OR USEABLE BY THE OWNER OR TO AREAS THAT CONTAIN ITEMS TO REMAIN THAT WILL BE DAMAGED BY
WEATHER.
10 ALL ITEMS INDICATED TO BE REMOVED AND/OR DEMOLISHED SHALL REMAIN THE PROPERTY OF THE OWNER. THE CONTRACTOR SHALL REVIEW WITH THE OWNER IF ANY ITEMS TO BE REMOVED AND/OR DEMOLISHED ARE TO BE RETAINED BY THE OWNER PRIOR TO ANY DEMOLITION WORK BEING PERFORMED. ALL ITEMS TO BE RETAINED BY THE OWNER SHALL BE REMOVED BY THE CONTRACTOR AND DELIVERED TO THE OWNER IN THE CONDITION FOUND PRIOR TO ANY WORK BEING PERFORMED. ALL OTHER ITEMS INDICATED TO BE REMOVED AND/OR DEMOLISHED SHALL BE DISPOSED OF OFF SITE BY THE CONTRACTOR IN A LAWFUL
MANNER.
11 THE CONTRACTOR SHALL REPLACE OR REPAIR ANY ITEMS DAMAGED BY THE CONTRACTOR OR ANY OF ITS AGENTS TO A MINIMUM CONDITION MATCHING THE ITEMS' CONDITION AT THE START OF CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER.
12 THE CONTRACTOR SHALL REPAIR ANY MATERIALS, SYSTEMS, OR FINISHES WITHIN OR OUTSIDE OF THE GENERAL WORK AREA THAT ARE REQUIRED TO BE DISTURBED TO COMPLETE THE ENTIRE SCOPE OF WORK ASSOCIATED WITH BUILDING SYSTEM CONNECTIVITY.
13 THE CONTRACTOR SHALL PREPARE ALL SURFACES AFFECTED BY DEMOLITION OPERATIONS TO RECEIVE NEW WORK AS BOTH INDICATED WITHIN THESE DRAWINGS AND SPECIFICATIONS/PROJECT MANUAL AND AS RECOMMENDED BY THE MANUFACTURERS'
WRITTEN INSTRUCTIONS FOR THE INSTALLATION OF EACH RESPECTIVE PRODUCT.
14 THE CONTRACTOR SHALL REMOVE EXISTING FINISHES AS INDICATED THROUGHOUT THE CONTRACT DOCUMENTS AND ENSURE THAT SUBSTRATE CONDITIONS ARE SMOOTH AND IN SATISFACTORY CONDITION TO RECEIVE NEW WORK.
15 THE CONTRACTOR SHALL REMOVE ALL ANCHORS, FASTENERS, WALL HANGERS, AND MISCELLANEOUS EXTRUSIONS AND APPURTENANCES OF ITEMS BOTH NO LONGER INSTALLED AND ITEMS REMOVED THROUGH DEMOLITION PROCEDURES.
16 THE CONTRACTOR SHALL COORDINATE ANY SAW CUTS WITHIN THE EXISTING SLABS WITHIN THE NEW WORK AREA AS REQUIRED TO INSTALL NEW ELECTRICAL CONDUIT, PLUMBING, AND/OR STRUCTURAL ELEMENTS. CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND DEPTH WITH THE FULL SET OF DOCUMENTS. REPLACE AND REPAIR CONCRETE AND FLASH AS REQUIRED TO CREATE
A FLUSH SUBSTRATE AFTER COMPLETION OF WORK TASKS.
GENERAL PROJECT NOTES
1 THE FOLLOWING GENERAL NOTES APPLY TO THE ENTIRE PROJECT.
2 THE CONTRACTOR SHALL EXAMINE ALL CONTRACT DOCUMENTS AND ALL SPECIFICATIONS AND DRAWINGS FOR THE PROJECT, INCLUDING THOSE THAT MAY PRIMARILY PERTAIN TO
WORK THAT THE CONTRACTOR NORMALLY DOES NOT PERFORM WITH ITS OWN FORCES. THE CONTRACTOR SHALL USE ALL OF THE PROJECT DRAWINGS AND SPECIFICATIONS FOR A COMPLETE UNDERSTANDING OF THE PROJECT AND ITS WORK, TO DETERMINE THE TYPE OF CONSTRUCTION AND SYSTEMS, FOR COORDINATION, TO DETERMINE WHAT OTHER WORK MAY BE INVOLVED THROUGHOUT, TO ANTICIPATE AND NOTIFY OTHERS WHEN THEIR COORDINATED EFFORTS WILL BE REQUIRED, AND ALL OTHER RELEVANT MATTERS
RELATED TO THE PROJECT AND ITS WORK.
3 IF THERE IS ANY INCONSISTENCY IN THE QUALITY OR QUANTITY OF THE WORK REQUIRED UNDER THE CONTRACT DOCUMENTS, THEN THE CONTRACTOR SHALL (1) IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF SUCH INCONSISTENCY AND (2) PROVIDE THE BETTER QUALITY OF OR GREATER QUANTITY OF WORK OR MATERIALS, UNLESS OTHERWISE ORDERED IN WRITING BY THE OWNER. COMPUTED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE DIMENSIONS. THE CONTRACT DOCUMENTS GENERALLY SET FORTH THE BASIS AND ANALYSIS OF DESIGN, AND THE CONTRACTOR SHALL OBTAIN SUCH INFORMATION AS MAY BE NECESSARY TO SATISFACTORILY PERFORM AND COMPLETE THE WORK.
4 THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF DRAWINGS WHICH, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE INDEX OF DRAWINGS AND WITHIN THE SPECIFICATIONS. THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE AND MAY REQUIRE REFERENCE TO THE DRAWINGS OF ANOTHER DISCIPLINE. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR UTILIZED BY THE CONTRACTOR. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES, AND SUPPLIERS WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS, SUPPLIERS, AND VENDORS BASED ON THE ENTIRE SET OF THESE DOCUMENTS. NO ADDITIONAL COMPENSATION WILL BE DUE TO A CONTRACTOR FOR ANY ISSUES AS A RESULT OF ANY USE OF AN INCOMPLETE SET OF CONSTRUCTION DOCUMENTS.
5 AT WALLS WITH SOUND ATTENUATION BLANKETS, CONTRACTOR SHALL SEAL DOOR FRAMES, GLAZED OPENING FRAMES, INTERSECTIONS, AND OTHER PENETRATIONS WITH
ACOUSTICAL SEALANT.
6 VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT, OR BY OTHERS. UNLESS NOTED OTHERWISE, ALL MATERIALS AND EQUIPMENT TO BE INSTALLED PER THE APPLICABLE PROVISIONS OF THESE DOCUMENTS AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
7 CUTTING INTO NEW WORK OF OTHER TRADES SHALL BE DONE BY THE TRADE REQUIRING THE CUTTING. ALL CUTTING SHALL BE DONE IN A NEAT MANNER USING SAWS WHERE POSSIBLE. ALL PATCHING AND PAINTING REQUIRED AS A RESULT OF THIS CUTTING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. PROVIDE ADEQUATE TEMPORARY SUPPORT FOR WORK BEING CUT AND PATCHED TO PREVENT FAILURE. DO NOT ENDANGER OTHER WORK. PROVIDE ADEQUATE PROTECTION OF OTHER WORK DURING CUTTING AND
PATCHING TO PREVENT DAMAGE.
8 PROPERLY PREPARE ALL SURFACES FOR NEW FINISHES. PATCH WITH SEAMS WHICH ARE DURABLE AND AS INVISIBLE AS POSSIBLE. COMPLY WITH SPECIFIC TOLERANCES FOR THE TYPE
OF WORK BEING DONE.
9 ALL PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE SEALED WITH PROPER/APPROVED THROUGH PENETRATION FIRE STOP SYSTEM AS RECOGNIZED BY AND LISTED WITH
NATIONALLY AND ACCEPTED TESTING LABORATORIES.
10 OBTAIN ARCHITECT'S SPECIFIC APPROVAL PRIOR TO DEVIATING FROM THE CONTRACT DOCUMENTS. THE ARCHITECT'S RESPONSIBILITY IS LIMITED TO THE ITEMS SHOWN ON THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO COMPLY WITH STANDARD BUILDING AND CONSTRUCTION PRACTICES AND MANUFACTURER'S RECOMMENDATIONS FOR ALL ITEMS NOT SPECIFICALLY INDICATED AND DETAILED ON THE DRAWINGS. FOLLOW THE BEST TRADE PRACTICES AND ENGINEERING FOR THE ITEMS NOT
SPECIFICALLY DETAILED AND INDICATED.
11 ALL PARTS OF THE WORK, INCLUDING MATERIALS, METHODS, ASSEMBLIES, ETC, MUST COMPLY WITH THE MINIMUM REQUIREMENTS OF THE GOVERNING REGULATIONS OF ALL FEDERAL, STATE, DISTRICT, AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT AS WELL AS THOSE GREATER REQUIREMENTS INDICATED BY THE CONTRACT DOCUMENTS. NO PART OF THE CONTRACT DOCUMENTS MAY BE CONSTRUED TO REQUIRE OR PERMIT WORK CONTRARY TO A GOVERNING REGULATION.
12 THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A CURRENT SET OF CONSTRUCTION DRAWINGS ON SITE DURING CONSTRUCTION. THE CONTRACTOR SHALL INDICATE ON THESE DRAWINGS ALL APPROVED CHANGES TO THE WORK. THIS SET OF DRAWINGS SHALL BE TURNED OVER TO THE OWNER/CLIENT WHEN THE PROJECT IS COMPLETE.
13 THE BUILDING HAS BEEN DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE DEMOLITION, ERECTION PROCEDURES, SEQUENCE, AND TO ENSURE THE STABILITY OF ITS COMPONENTS AND PARTS, AND THE ADEQUACY OF TEMPORARY OR INCOMPLETE CONNECTIONS DURING ERECTION. THIS INCLUDES THE ADDITION OF ANY GUYS, SHORING, SHEETING OR TEMPORARY BRACING AND TIE-DOWNS THAT MIGHT BE NECESSARY. SUCH MATERIALS ARE NOT SHOWN ON THE DRAWINGS. IF APPLIED, THEY SHALL BE REMOVED AS CONDITIONS PERMIT, AND SHALL REMAIN THE CONTRACTOR'S
PROPERTY.
14 THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL GRADING, MECHANICAL, AND ELECTRICAL PERMITS, AND ALL OTHER RELATED PERMITS REQUIRED TO COMPLETE THE WORK. ALL PLUMBING, ELECTRICAL & MECHANICAL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THE LATEST ADOPTED BUILDING CODE AND SHALL BE SUBJECT TO FIELD
INSPECTION BY THE AGENCIES HAVING JURISDICTION.
15 MANNS WOODWARD STUDIOS, INC. HAS NO EXPERTISE IN, AND TAKES NO RESPONSIBILITY FOR, CONSTRUCTION MEANS AND METHODS OR JOB SITE SAFETY DURING CONSTRUCTION. PROCESSING AND/OR APPROVING SUBMITTALS MADE BY THE CONTRACTOR CONTAINING INFORMATION RELATED TO CONSTRUCTION METHODS, OR SAFETY ISSUES, OR PARTICIPATION IN MEETINGS WHERE SUCH ISSUES MIGHT BE DISCUSSED. IT SHALL NOT BE CONSTRUED AS VOLUNTARY ASSUMPTION BY MANNS WOODWARD STUDIOS, INC. OR ANY RESPONSIBILITY FOR SAFETY PROCEDURES. IT IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING CONSTRUCTION. MANNS WOODWARD STUDIOS, INC. DOES NOT ENGAGE IN, AND DOES NOT SUPERVISE THE CONSTRUCTION PROCESS.
16 THESE DRAWINGS ARE THE PROPERTY OF MANNS WOODWARD STUDIOS, INC. AND MAY NOT BE MODIFIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. REPRODUCTIONS OF THE DRAWINGS MUST BEAR THE NAME OF THE ARCHITECT AND PROJECT LOCATION. THESE DRAWINGS ARE FULLY PROTECTED BY FEDERAL AND STATE COPYRIGHT LAWS; ANY
INFRINGEMENT WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW.
17 ALL DEVICES INCLUDING SWITCHES, PLATES, THERMOSTATS, CONTROL PANELS, ETC. SHALL BE COORDINATED BY THE CONTRACTOR BASED UPON THE FOLLOWING CRITERIA: A.
DEVICES LOCATED WITHIN 36" OF EACH OTHER HORIZONTALLY (IN PLAN VIEW) OF EACH OTHER SHALL BE INSTALLED SUCH THAT THE TOPS OF ALL DEVICES ARE ALIGNED OR THE CENTERLINE OF DEVICES ARE MAINTAINED. B. DEVICES LOCATED VERTICALLY (TWO OR MORE STACKED DEVICES) SHALL BE INSTALLED SUCH THAT THE CENTERLINES ARE MAINTAINED.
SEE DIAGRAMS FOR REFERENCE. ADA REACH HEIGHTS AND DEVICE REQUIREMENTS PER CODE SUPERCEDE THIS NOTE AND WHERE IN CONFLICT SHALL REQUIRE COORDINATION AND
APPROVAL FROM THE ARCHITECT.
GENERAL PARTITION NOTES
1 PROVIDE FIBERGLASS REINFORCED MOISTURE RESISTANT GYPSUM WALL BOARD IN ALL EQUIPMENT ROOMS, JANITOR'S CLOSETS, RESTROOMS, KITCHENS AND OTHER WET AREAS. PROVIDE FIBERGLASS REINFORCED MOISTURE RESISTANT WALL BOARD IN ALL OTHER
AREAS WITHIN 8'-0" OF WATER SOURCE.
2 CONTRACTOR SHALL PROVIDE BLOCKING AND NAILERS AS REQUIRED TO SUPPORT ALL NEW WORK, INCLUDING ITEMS TO BE PROVIDED
AND/OR INSTALLED BY OWNER.
3 PROVIDE CONCRETE BACKER BOARD IN LIEU OF GYPSUM WALL BOARD WHERE TILE FINISH IS INDICATED.
4 INTERIOR METAL STUD FRAMING AND EXTERIOR FURRING/MISCELLANEOUS FRAMING, UNLESS NOTED OTHERWISE, SHALL BE A MINIMUM
OF 20 GAUGE THICKNESS AND SHALL BE SPACED 16 INCHES ON CENTER. METAL STUD PROVIDER/INSTALLER SHALL BE RESPONSIBLE FOR THE DELEGATED DESIGN AND FINAL ENGINEERING OF ALL METAL STUD FRAMING COMPONENTS INCLUDING BUT NOT LIMITED TO SOFFITS, BULKHEADS, PARTITIONS, FURRING, CEILINGS, AND MISCELLANEOUS FRAMING/BLOCKING REQUIRED TO SUPPORT AND COMPLETE THE WORK. METAL STUD PROVIDER/INSTALLER/DESIGNER SHALL PROVIDE METAL STUDS IN WIDTHS INDICATED. METAL STUD DESIGNER SHALL FIRST INCREASE METAL STUD THICKNESS, SECOND DECREASE METAL STUD SPACING TO 12 INCHES ON CENTER, AND THIRD INCREASE STUD WIDTH WHERE ADJUSTING STUD THICKNESS AND SPACING ARE INSUFFICIENT TO COMPLY WITH REQUIREMENTS.
5 MOISTURE RESISTANT GYPSUM WALL BOARD SHALL BE UTILIZED IN ALL AREAS WHERE GYPSUM WALL BOARD IS TO BE DIRECTLY ADHERED TO CONCRETE OR MASONRY SURFACES IN INTERIOR APPLICATIONS. SUBSTRATE SHALL BE CLEANED AS REQUIRED AND FREE OF DUST, DEBRIS, AND MOISTURE PRIOR TO ADHESION AND FINISHING.
6 CONSTRUCTION OF RATED WALL ASSEMBLIES SHALL BE STRICTLY ADHERED TO IN ACCORDANCE WITH UL AND/OR GYPSUM ASSEMBLY
SPECIFICATIONS. REFER TO CODE PLANS FOR ADDITIONAL INFORMATION.
SCHEDULE - INTERIOR PARTITION & WALL TYPE
MARK WIDTH DESCRIPTION
FIRE RATING
STC
RATINGRATING
ASSEMBLY
REF
P5 6 5/8" 6" METAL STUD W/ 5/8" GWB ONE SIDE UP TO 12'-0" AFF
P7 4 7/8" 3-5/8" METAL STUD W/ 5/8" GYPSUM WALL BOARD EACH SIDE UP TO 12'-0" AFF
P8 7 1/4" 6" METAL STUD W/ 5/8" GYPSUM WALL BOARD EACH SIDE UP TO 12'-0" AFF
P T
No. DATE
RESTROOM
AA
RESTROOM
BB
V2-A103
V2-A103
V2-A103
BB-A
AA-A
P7
P7
P5
P7
P7
P8
V2-A1038
V2-A1039
V2-A103
EXISTING WALL TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED (SEE DEMO PLANS)
NEW WALL/PARTITION
PLAN LEGEND
AREA NOT IN SCOPE
1/4" = 1'-0"2 FIRST FLOOR PLAN
SHEET NUMBER:
ORIGINAL ISSUE DATE:
SHEET REVISION SCHEDULE:
SUBMISSION:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
SEAL:
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
S T U D I O S
8098 SANDPIPER CIR, SUITE H
NOTTINGHAM, MD 21236
/2 9:
:2
AM
LAST PROJECT REVISION: No B | 04/22/26
V2-A101
FLOOR PLANS
08/28/2026
PROJECT NUMBER: 23-194
PERMIT/BID/CONSTRUCTION
H A
RF
O
RD
C O U N
TY
M D
-2 B A N K B U
IL
D
IN
G R
EN
O V A
TI
O N
C O U
RT
H O U
SE
R
ES
TR
O O M S
W
ES
T C O U
RT
LA
N D S
TR
EE
T, B
EL
A
IR
M D
1/4" = 1'-0"1 FIRST FLOOR DEMOLTION PLAN
P T
GENERAL PLAN NOTES
1 G.C. SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. REPORT ANY
DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH ANY WORK.
2 ALL DOOR JAMBS IN METAL STUD WALL SHALL BE A MINIMUM OF 4" FROM ADJACENT / PERPENDICULAR WALLS UNLESS NOTED
OTHERWISE.
LEGEND - KEYNOTE LEGEND
KEY NOTE
1 REMOVE EXISTING MASONARY W/ PLASTER FINISH ABD ALL ASSOCIATED APPURTENANCES IN THEIR ENTIRETY, FOR NEW
OPENING.
2 REMOVE EXISTING CARPET FLOOR FINISH, FLOOR BASE, WALL FINISHES, AND ALL ASSOCIATED APPURTENANCES IN THEIR
ENTIRETY.
3 LOCATION OF TEMPORARY CONSTRUCTION PARTITION.
4 DEMOLISH PORTION OF FLOOR FOR NEW PLUMBING.
No. DATE
RESTROOM
AA
1/ 4"
6' -8
7/ 8"
4 7/8" 8'-1 1/2"
V2-A103
V2-A103
OPP/SIM
AA-A
GB5
TD1
SN1
GB4
P7
CT-1
P7
P8
CL
1'-5" 8 1/8"
LD1
V2-A1038
PT1
GB1
1' -8 "P5
CL
1'-6"
RESTROOM
BB
7/ 8"
6' -8
5/ 8"
4 7/8" 8'-1 1/2"
V2-A103
CT-1
GB4
LD1
GB5
SN1
TD1
BB-A
P5
P7
P7
CL1'-6"
V2-A1039
V2-A103
PT1
CL 1'-5" 8 1/8"
P5
1' -8
B-1
P-1
FIRST FLOOR
0"
B-1
GB1
GB5
CLCL
1'-0" 2'-0"
TD1
SN1
FIRST FLOOR
0"
GB4
MR1CT-2
B-1
PT1
B-1
P-2
CT-2
CL
10"
LD1
BB-A
P-1
FIRST FLOOR
0"
EXISTING EXPOSED WAFFLE
SLAB TO REMAIN
'-0
CLG-1
8'-10"
P7 P8
V2-A103 11V2-A103
Sim
3 5/8" STRUCTURAL
METAL STUD @ 16" O.C.
MIN. W/(1) ROW OF
BRIDGING MID-SPAN
13'-2"
11'-0"
MAX.
8" Ø
OF SLAB ONLY
PENETRATION
IN THIN PART
8"Ø MAX CORE WITHOUT SLAB
REINFORCING
HOLES MAY ONLY BE CORED IN
THIN PART OF SLAB - NO
PENETRATIONS IN WAFFLE RIBS
IS PERMITTED
PE
R M
IT
TE
D
N O
PE
N
ET
R
AT
IO
N S
P7
CLG-1
8'-10"
9'-0"
10'-2"
3 5/8" STRUCTURAL METAL
JOISTS/STUD @ 16" O.C. MIN.
w/ (1) ROW OF BRIDGING MID-
SPAN
P-1, FIELD PAINT
FIRST FLOOR
0"
P-1
AA-A
B-2
EXISTING DRYWALL REVEAL
FIRST FLOOR
0"
BB-AEX122IIII
P-1
B-2
FIRST FLOOR
0"
NEW TILE BASE, TYP.
NEW WALL TILE, TYP.
EXISTING WALL
EXISTING SLABNEW FLOOR TILE, TYP.
EXISTING WAFFLE SLAB
NEW GWB CEILING
ASSEMBLY, TYP.
MATCH WITH
EXISTING BASE, TYP.
SHEET NUMBER:
ORIGINAL ISSUE DATE:
SHEET REVISION SCHEDULE:
SUBMISSION:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
SEAL:
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
S T U D I O S
8098 SANDPIPER CIR, SUITE H
NOTTINGHAM, MD 21236
/2 9:
:2
AM
LAST PROJECT REVISION: No B | 04/22/26
V2-A103
ENLARGED PLANS, FINISHES & INT.
ELEVATIONS
08/28/2026
PROJECT NUMBER: 23-194
PERMIT/BID/CONSTRUCTION
H A
RF
O
RD
C O U N
TY
M D
-2 B A N K B U
IL
D
IN
G R
EN
O V A
TI
O N
C O U
RT
H O U
SE
R
ES
TR
O O M S
W
ES
T C O U
RT
LA
N D S
TR
EE
T, B
EL
A
IR
M D
1/4" = 1'-0"1 ENLARGED PLAN - TOILET AA
1/4" = 1'-0"2 ENLARGED PLAN - TOILET BB
1/4" = 1'-0"5 BB TOILET - SOUTH
1/4" = 1'-0"6 BB TOILET - WEST
1/4" = 1'-0"3 BB TOILET - NORTH
1/4" = 1'-0"4 BB TOILET - EAST
1/4" = 1'-0"7 TOILET ROOM SECTION
3/4" = 1'-0"10 WAFFLE SLAB PLUMBING PENETRATION DETAIL
SCHEDULE - TOILET ROOM ACCESSORIES
MARK DESCRIPTION BOD MANUFACTURER BOD MODEL COMMENTS
GB1 18" GRAB BAR BOBRICK B-5806-18
GB4 36" GRAB BAR BOBRICK B-5806-36
GB5 42" GRAB BAR BOBRICK B-5806-42
LD1 LIQUID SOAP DISPENSER PURELL ES8
MR1 20" x 40" CHANNEL FRAME MIRROR AMERICAN SPECIALTIES 0620
PT1 MANUAL PAPER TOWEL DISPENSER SCOTT 46253
SN1 SURFACE MOUNTED SANITARY WASTE RECEPTACLE GRAINGER 1ECK9
TD1 TWIN TOILET PAPER DISPENSER IN-SIGHT DISPENSERS 09608
SCHEDULE - FINISHES
ROOM INFORMATION
FLOOR FINISH BASE
WALL FINISH CEILING
FINISH REMARKSRM # ROOM NAME NORTH SOUTH EAST WEST
AA RESTROOM CT-2 B-1 P-1/CT-1 P-1/CT-1 P-1/CT-1 P-1/CT-1 GYPSUM
BB RESTROOM CT-2 B-1 P-1/CT-1 P-1/CT-1 P-1/CT-1 P-1/CT-1 GYPSUM
SCHEDULE - MATERIAL FINISH KEY
FINISH MARK DESCRIPTION BOD MANUFACTURER BOD MODEL/PRODUCT LINE BOD COMMENTS
B-1 6" CERAMIC TILE COVE BASE FLORIDATILE SERENDIPITY - FATE WARM GRAY GROUT - LATICRETE - 45 RAVEN
B-2 MATCH EXISTING BASE MATCH EXISTING MATCH EXISTING
CT-1 2" x 2" CERAMIC TILE FLORIDATILE SERENDIPITY - FATE WARM GRAY FLOOR TILE - GROUT - LATICRETE - 45 RAVEN CT-2 12" x 24" CERAMIC TILE ARCHITESSA DISTRICT - SILVER HONED WALL TILE - GROUNT - LATICRETE - 97 IRON
P-1 FIELD PAINT SHERWIN WILLIAMS SW7029 AGREEABLE GREY - EGGSHELL
P-2 TRIM PAINT SHERWIN WILLIAMS SW 7005 PURE WHITE
1 1/2" = 1'-0"11 SOFFIT DETAIL
1/4" = 1'-0"8 EXTERIOR RESTROOM AA - WEST
1/4" = 1'-0"9 EXTERIOR RESTROOM BB - WEST
1 1/2" = 1'-0"12 EXISTING WALL SECTION DETAIL
No. DATE
VARIES
VA
RI
ES
F
1. SEE DOOR SCHEDULE FOR ACTUAL PANEL DIMENSIONS.
HOLLOW METAL STANDARD
FRAME
JAMB VARIES JAMB VARIES
PANEL(S) WIDTH VARIES
DO
OR
P
AN
EL
(S ) H
EI
GH
T
VA
RI
ES
HE
AD
V
AR
IE
S
OVERALL WIDTH VARIES
OV
ER
AL
L H
EI
GH
T
VA
RI
ES
HM ST
1.) SEE DOOR SCHEDULE FOR FRAME DIMENSION VARIABLES
STANDARD
FRAME
5' -0
2"
TACTILE
SURFACE
" M
IN
DOUBLE
DOOR
FRAME
5' -0
2"
TACTILE
SURFACE
" M
IN
SIDE LITE
FRAME
5' -0
2"
TACTILE
SURFACE
" M
IN
. PROVIDE A BLANK GLASS
BACKUP ON OPPOSITE SIDE
OF THE GLASS EXACTLY
BEHIND THE SIGN
1.
2.
3.
4.
5.
6.
7.
PROVIDE SIGNAGE AT ALL OF THE FOLLOWING LOCATIONS:
ADA COMPLIANT IDENTIFICATION ROOM SIGNAGE WITH REMOVABLE INSERT AT ALL ROOMS OTHER THAN MECHANICAL ROOMS AND TOILET ROOMS.
SIGNS SHALL INDICATE ROOM NUMBER AND PROVIDE REMOVABLE INSERT FOR ROOM NAMES.
ADA COMPLIANT IDENTIFICATION ROOM SIGNAGE AT MECHANICAL ROOMS AND TOILET ROOMS. SINGLE OCCUPANT TOILET ROOMS SHALL BE IDENTIFIED AS UNI-SEX. SINGLE OCCUPANT TOILET ROOMS WITH CHANGING STATIONS SHALL BE IDENTIFIED AS FAMILY RESTOOMS.
ADA COMPLIANT IDENTIFICATION EXIT SIGNAGE AT ALL DOORS LEADING TO RATED EXITS.
ADA COMPLIANT IDENTIFICATION FLOOR LEVEL SIGNAGE AT ALL FLOOR LANDINGS OF STAIRS AND RAMPS.
ADA COMPLAINT INFORMATIONAL SIGNAGE AT ALL AED STATIONS AND FIRE EXTINGUISHERS.
ADA COMPLIANT INFORMATIONAL SIGNAGE INDICATING THE MAXIMUM OCCUPANCY OF ALL ASSEMBLY SPACES.
ADA COMPLIANT INFORMATIONAL SIGNAGE SHALL BE PROVIDED AT ALL ELEVATORS.
CONTINUOUS SEALANT
BOTH SIDES, TYPICAL
H.M. FRAME, PAINTED
DH-1
DJ-1
EXISTING MASONRY WALL
TO REMAIN
7 3/4"
5/8" GWB EACH SIDE
EQ 3 5/8"
2 3/8"
1 3/4" EQ
CORNER BEAD, BOTH SIDES,
FLOAT SMOOTH, TYPICAL
H.M. FRAME, PAINTED
EXISTING MASONRY WALL
TO REMAIN
7 3/4"
5/8" GWB
EQ
3 5/8" 2 3/8"
1 3/4" EQ
1/2"
CORNER BEAD, FLOAT
SMOOTH, TYPICAL
TILE BACKER BOARD WALL TILE, TYP.
V.I.F.
9 1/4"
SCHLUTER
TRIM, TYP.
V.I.F.
9 3/8"
C L 1"
2" 5/ 8"
C L
5/ 8"
2" 1"
TH-1TH-1
CARPET - PORCELAIN TILE
EXISTING CARPET
DOOR PANEL
PORCELAIN TILE
DOOR FRAME
ADA MARBLE
THRESHOLD, TYP.
SCHEDULE - DOOR
MARK
DOOR PANEL FRAME DETAILS RATINGS
HARDWARE COMMENTSSIZE TYPE THICKNESS MATERIAL FINISH FRAME TYPE
SIZE SUMMARY
FRAME PROFILE
SUMMARY
MATERIAL FINISH HEAD JAMB THRESHOLD STC
FIRE
(MINUTES)
OVERALL
HEIGHT
OVERALL
WIDTH HEAD JAMB
AA-A 3'-0" x 8'-5" PANEL : F 1 3/4" SCWD STAIN TO MATCH EXISTING HM ST 8'-7" 3'-4" 2" 2" HM PAINT TO MATCH EXISTING DH-1 DJ-1 TH-1 90 24 BB-A 3'-0" x 8'-5" PANEL : F 1 3/4" SCWD STAIN TO MATCH EXISTING HM ST 8'-7" 3'-4" 2" 2" HM PAINT TO MATCH EXISTING DH-1 DJ-1 TH-1 90 24
DOOR PANEL TYPE FRAME TYPE
SHEET NUMBER:
ORIGINAL ISSUE DATE:
SHEET REVISION SCHEDULE:
SUBMISSION:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
SEAL:
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
S T U D I O S
8098 SANDPIPER CIR, SUITE H
NOTTINGHAM, MD 21236
/2 9:
:2
AM
LAST PROJECT REVISION: No B | 04/22/26
V2-A600
DOOR AND SIGNAGE INFORMATION
08/28/2026
PROJECT NUMBER: 23-194
PERMIT/BID/CONSTRUCTION
H A
RF
O
RD
C O U N
TY
M D
-2 B A N K B U
IL
D
IN
G R
EN
O V A
TI
O N
C O U
RT
H O U
SE
R
ES
TR
O O M S
W
ES
T C O U
RT
LA
N D S
TR
EE
T, B
EL
A
IR
M D
SCHEDULE - DOOR HARDWARE
SET
No. HW DESCRIPTION HW FUNCTION NARRATIVE 24 COURTHOUSE TOILET CARD READER TO BE USED BY AUTHORIZED PERSONS TO GAIN ENTRY FROM THE PUSH SIDE OF THE OPENING.
CARD READER TO BE USED TO UNLOCKED THE PUSH SIDE LEVER OF THE ELECTRIFIED PRIVACY.
PROJECTING THE DEADBOLT BY USE OF THE PUSH SIDE CYLINDER OR PULL SIDE TURNPIECE OF THE ELECTRIFIED
PRIVACY SET WILL DEACTIVATE THE CARD READER.
RETRACTING THE DEADBOLT BY USE OF THE PUSH SIDE CYLINDER, PULL SIDE TURNPIECE OR ROATATING THE PULL
SIDE LEVER OF THE ELECTRIFIED PRIVACY SET WILL ACTIVATE THE CARD READER.
CARD READER CANNOT BE DEACTIVATED UNLESS THE DOOR IS IN THE CLOSED POSITION.
PULL SIDE LEVER OF THE ELECTRIFIED PRIVACY SET ALWAYS FREE FOR IMMEDIATE EGRESS.
GENERAL DOOR NOTES
1 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING OPENINGS/MODIFIED OPENINGS PRIOR TO FABRICATION
OF DOORS AND FRAMES.
2 DETAILS MAY VARY AT EACH DOOR. VERIFY EACH CONDITION IN FIELD.
3 SEE PARTITION SCHEDULE, FLOOR PLAN, AND STRUCTURAL DRAWINGS FOR CONSTRUCTION OF WALLS
AND PARTITIONS.
4 ALL DOORS SHALL BE SET WITHIN OPENINGS TO ENSURE ADA APPROACH COMPLIANCE AS INDICATED
ON SHEET A0.3.
5 AT WALLS WITH SOUND ATTENUATION BLANKETS, CONTRACTOR SHALL SEAL DOOR FRAMES, GLAZED
OPENING FRAMES, INTERSECTIONS, AND OTHER PENETRATIONS WITH ACOUSTICAL SEALANT.
6 DOOR HARDWARE SHALL BE ADA COMPLIANT
NOT TO SCALE
ADA SIGNAGE MOUNTING LOCATIONS
1 1/2" = 1'-0"
DOOR DETAILS
3" = 1'-0"
THRESHOLD DETAILS
No. DATE x12x11x10 x13 xF xH xJ xM x14
OPEN TO ABOVE
NO DEMO
OPEN TO ABOVE
NO DEMO
13'-2"
11'-0"
13'-2"
11'-0" x12x11x10 x13 xF xH xJ xM x14
CLG-1
8'-10"
CLG-1
8'-10"
RESTROOM
BB
RESTROOM
AA
CLCL
2'-3 1/2" 4'-2" 1'-8"
C L C L
1' -8
3' -4
1' -8
CLCL
2'-3 1/2" 4'-2" 1'-8"
C L C L
1' -8
3' -4
1' -8
EXISTING WALL TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED (SEE DEMO PLANS)
NEW WALL/PARTITION
PLAN LEGEND
AREA NOT IN SCOPE
CEILING TYPE DETAILS
CLG-1
5/8" GWB, PAINTED, TYP.
3 5/8" METAL STUD @
16" OC, TYP.
EXISTING STRUCTURE
ABOVE
NO HANGING WIRES
SHEET NUMBER:
ORIGINAL ISSUE DATE:
SHEET REVISION SCHEDULE:
SUBMISSION:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
SEAL:
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
S T U D I O S
8098 SANDPIPER CIR, SUITE H
NOTTINGHAM, MD 21236
/2 9:
:2
AM
LAST PROJECT REVISION: No B | 04/22/26
V2-A800
RCPS, CEILING TYPES, & NOTES
08/28/2026
PROJECT NUMBER: 23-194
PERMIT/BID/CONSTRUCTION
H A
RF
O
RD
C O U N
TY
M D
-2 B A N K B U
IL
D
IN
G R
EN
O V A
TI
O N
C O U
RT
H O U
SE
R
ES
TR
O O M S
W
ES
T C O U
RT
LA
N D S
TR
EE
T, B
EL
A
IR
M D
GENERAL CEILING NOTES
1 CONTRACTOR SHALL COORDINATE FINAL FIELD LOCATION OF ALL EXIT SIGNS AND EMERGENCY LIGHTING WITH ARCHITECT PRIOR TO ROUGH-IN, TYP.
2 WHERE CEILINGS ARE EXPOSED ALL TIES, CABLES, AND SUPPORTS FOR CLOUDS, ELECTRICAL, MECHNICAL EQUIPMENT AND OTHER APPURTENANCES SHALL BE
INSTALLED IN A NEAT, ORGANIZED AND WORKMAN LIKE MANNER. VISIBLE TIES SHALL BE PLUMB/TRUE/SQUARE TO ELEMENTS, TIGHTLY WRAPPED, WITH EXCESS
WIRE NEATLY CUT.
3 CONTRACTOR SHALL COORDINATE THE COLOR AND FINISH OF ALL CEILING MOUNTED EQUIPMENT SUCH AS DIFFUSERS, RETURNS, SPEAKERS, ETC. WITH THE
ARCHITECT TO ENSURE THERE ARE NO STARK CONTRASTING COLORS.
4 WHERE ACT GRID LAYOUT AT EDGE CONDITIONS FOR 2X2 TILES REQUIRE TILES TO BE CUT TO LESS THAN 3", UTILIZE A 2X4 TILE IN LIEU OF THE 2X2 TILE. OMIT CILING GRID CROSS MEMBERS AS REQUIRED. NO TILE SHALL EXCEED 27" OR BE LESS THAN 3" AT PERIMETER CONDITIONS. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE GRID MAINS AS REQUIRED TO ACHIEVE THIS DESIGN INTENT.
SCHEDULE - CEILING TYPES
MARK DESCRIPTION
BOD
MANUFACTURER BOD MODEL COMMENTS
CLG-1 5/8" GWB ON 3 5/8" METAL STUDS @ 16" O.C. N/A N/A
1/4" = 1'-0"1 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN
1/4" = 1'-0"2 FIRST FLOOR REFLECTED CEILING PLAN
P T
RCP EQUIPMENT LEGENDRCP EQUIPMENT LEGEND
EXHAUST FAN LOCATION
RECESSED DOWNLIGHT LOCATION
No. DATE
1. THE MECHANICAL AND PLUMBING CONTRACT DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO INDICATE SCOPE AND THE GENERAL ARRANGEMENT OF THE SYSTEMS. WHERE APPLICABLE THE FOLLOWING NOTES SHALL APPLY TO ALL
MECHANICAL (HVAC, PLUMBING, PIPING AND FIRE PROTECTION) SYSTEMS.
2. THOUGH SOME DUCTWORK AND PIPING OFFSETS AND TRANSITIONS ARE INDICATED, IT IS NOT THE INTENT OF THE DRAWINGS TO SHOW ALL OFFSETS AND TRANSITIONS REQUIRED. THE CONTRACTOR SHALL FULLY COORDINATE THE MECHANICAL WORK WITHIN ITSELF AND WITH THE WORK OF ALL OTHER TRADES TO PROVIDE COMPLETE AND OPERABLE
SYSTEMS WITHOUT INTERFERENCES.
3. DEMOLISH ALL SYSTEMS AND EQUIPMENT INDICATED TO BE REMOVED BY DRAWINGS OR NOTES. WHERE EXISTING SYSTEMS ARE TO REMAIN IN USE, REMOVE ALL UNUSED PORTIONS OF THE SYSTEMS TO A POINT AS CLOSE TO THE REMAINING SYSTEMS AS POSSIBLE AND CAP WITH MATERIALS AND CONSTRUCTION MATCHING THE REMAINING SYSTEMS'
CUT END.
4. PROVIDE APPROVED FIRE STOPPING MATERIAL AROUND ALL DUCTWORK AND PIPING PENETRATIONS (NEW AND EXISTING) THROUGH FIRE RATED FLOORS AND WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIRE RATED FLOORS AND WALLS. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FLOORS AND FIRE RATED
WALLS AND FIRE/SMOKE DAMPERS AT ALL PENETRATIONS THROUGH SHAFT ENCLOSURES.
5. SUPPORT ALL EQUIPMENT (I.E. AHU'S, HEATERS, FANS, AIR TERMINAL UNITS, ETC.) FROM STRUCTURE WITH SPECIFIED
VIBRATION ISOLATION.
6. PROVIDE ACCESS PANELS WHERE REQUIRED FOR ADEQUATE ACCESS TO ALL CONCEALED EQUIPMENT, VALVES, DAMPERS AND CONTROLS.
7. ALL DUCT SIZES REFER TO INTERNAL FREE AREA. REFER TO DRAWINGS AND SPECIFICATIONS FOR INTERNAL INSULATION
AND SOUND LINING PRIOR TO FABRICATION.
8. ALL DUCTWORK SHALL BE CONSTRUCTED OF RIGID SHEET METAL UNLESS OTHERWISE NOTED.
9. COORDINATE DIFFUSER, REGISTER AND GRILLE LOCATIONS AND BORDER TYPES WITH ARCHITECTURAL REFLECTED
CEILING PLAN.
10. INSTALL DUCTWORK AND PIPING MAINS TIGHT TO UNDERSIDE OF STRUCTURE UNLESS OTHERWISE INDICATED.
11. REFER TO MECHANICAL DETAILS FOR TYPICAL EQUIPMENT CONNECTIONS.
12. PIPING CONNECTIONS TO HEATING AND COOLING COILS SHALL BE MADE TO PROVIDE COUNTER FLOW BETWEEN WATER
AND AIR.
13. PROVIDE CONDENSATE DRAIN PIPING FROM EACH AIR HANDLING UNIT TO NEAREST FLOOR DRAIN. PROVIDE CLEAN OUT
AT EACH ELBOW. SIZE PER MANUFACTURER.
14. AIR CONDITIONING (A/C) CONDENSATE PIPING SHALL BE EXTENDED FROM ALL A/C CONDENSATE SOURCE EQUIPMENT (AHU'S, FAN COIL UNITS, UNIT VENTILATORS, SPLIT SYSTEM A/C UNITS, ETC.) AND CONNECTED TO THE NEAREST STORM
WATER PIPE/DRAIN LOCATION. SIZE PER MANUFACTURER.
15. REFER TO STRUCTURAL DRAWINGS FOR EXACT LOCATION OF DUCT PENETRATIONS THRU ROOF. PROVIDE DUCT
TRANSITIONS AT ROOF FOR ALL ROOF MOUNTED EQUIPMENT.
16. PATCH AND SEAL ALL REMAINING OPENINGS (NEW AND EXISTING) THROUGH FLOORS, CEILINGS, WALLS, AND ROOF RESULTING FROM DEMOLITION OR NEW WORK WITH MATERIALS AND FINISHES TO MATCH EXISTING CONSTRUCTION AND
FIRE RATING.
17. AS AN INTEGRAL PART OF THESE DOCUMENTS, THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
18. PRIOR TO THE BALANCING OF SYSTEMS BY THE AABC CERTIFIED BALANCING CONTRACTOR, ALL HIGH PRESSURE AND LOW PRESSURE SYSTEMS SHALL BE TESTED BY THE MECHANICAL CONTRACTOR FOR DUCT LEAKAGE. DUCT LEAKAGE SHALL NOT EXCEED 1% FOR A DURATION OF TEN (10) MINUTES. SEE SPECIFICATIONS FOR ADDITIONAL TESTING CRITERIA.
INSULATION MATERIALS SHALL NOT BE APPLIED UNTIL SYSTEMS HAVE BEEN WITNESSED, DOCUMENTED AND SUBMITTED TO MEET THE ABOVE TESTING REQUIREMENTS. REFER SPECIFICATIONS FOR SYSTEMS INDICATED AS LOW PRESSURE OR HIGH PRESSURE. THE BALANCE CONTRACTOR SHALL WITNESS AND CERTIFY ALL DUCT PRESSURE TESTS.
19. THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A TESTING AGENCY TO PLAN AND IMPLEMENT AN INDOOR AIR QUALITY CONSTRUCTION MANAGEMENT PLAN PER THE REQUIREMENTS OF THE INTERNATIONAL GREEN CONSTRUCTION
CODE.
20. CONTRACTOR SHALL VISIT THE SITE AND VERIFY EXISTING CONDITIONS PRIOR TO THE BEGINNING OF ANY WORK.
FAILURE TO VISIT THE SITE SHALL IN NO WAY RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY.
21. CONTRACTOR SHALL USE CARE WHEN PERFORMING SELECTIVE DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO BUILDING FINISHES, EQUIPMENT, FURNITURE, STRUCTURE, AND MECHANICAL/ELECTRICAL SYSTEMS AND EQUIPMENT. SHOULD ANY DAMAGE OCCUR THE CONTRACTOR SHALL RESTORE DAMAGED AREA/ITEMS TO ORIGINAL
CONDITION TO MEET THE OWNER'S…