2-2. Appendix A - JAZZ Shelter Specifications 1.pdf

PDF 417 KB Posted

Attached to
Purchase and Installation of Digital Displays for the Monterey-Salinas Transit District Transit Centers and JAZZ Shelters
Solicitation number
IFB #27-02
Issued by
Monterey County, San Francisco City, California

About this file

This is a technical specification document for a 24-foot custom shelter design developed by Tolar Manufacturing Company, Inc., in coordination with the Monterey-Salinas Transit District (MST) for their transit centers and JAZZ shelters in California. The shelter features a domed roof structure measuring 24 feet 4 inches in overall width with columns spaced 11 feet on center, providing a minimum clearance of 8 feet 2 3/8 inches at the front. The design incorporates custom glass display panels and schedule holders branded "JAZZ," LED lighting spaced 3 feet on center, stainless steel framing with 4-inch Schedule 80 pipe in a 180-grit brushed finish, polycarbonate lens components, and integrated camera locations for security surveillance. The shelter structure is supported by rear frame members constructed of 2-inch by 2-inch by 3/16-inch wall thickness aluminum tubing and stainless steel threaded rods with expansion anchors that anchor into 30-inch by 30-inch by 24-inch deep pad footings.

The specifications detail material requirements and construction standards including ASTM A-36 structural steel with a minimum yield strength of 36,000 PSI, 6063-T5 or greater aluminum alloy, and compliance with American Welding Society standards D1.1-00 for steel welding and D1.2-08 for aluminum welding. All structural welding must be performed at Tolar Manufacturing Company's facility. The design accommodates electrical service integration for camera power supply and LED lighting systems. The document includes a floor and foundation plan with precise dimensional details and camera location specifications to support the installation of digital displays within the shelter environment for the MST transit system.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DETAIL A

SCALE 1 / 4

A A

B B

C C

D D

DESCRIPTION

CUSTOMER/VENDOR

MATL.

SCALE

SIZE

DATE DRAWN BY:

DWG NO.

Tolar Manufacturing Company, Inc 258 Mariah Circle, Corona CA. 92879

24' CUSTOM SHELTER

D

16730-00 5/18/2012 Emeza

\\TOLAR3\Data\Inventor\Shelters\Ad Custom Dome\16730-00.idw

REV. NO.

SHEET NO.

1 OF 2 MST

1/32

A

B B

11'-0" C/C COLUMNS 11'-0" C/C COLUMNS

24'-4" O/A ROOF

1'-2" 1'-2"3'-0" C/C LEDs 3'-0" C/C LEDs 3'-0" C/C LEDs 3'-0" C/C LEDs

1'-0"

6' -1

1/

2" T

OP

O

F

BA

CK

P

AN

EL

7' -1

5/

8" M

IN

. C

LE

AR

AN

CE

8' -4

/8

" M

IN

. C

LE

AR

AN

CE

A

T

FR

ON

T

9' -1

/8

" O /A

H

EI

GH

T

6' -3

" B

AC

K

PA

NE

L

8 1/2" CLEARANCE

REAR FRAME SUPPORTS (4X)

STN STL THREARED ROD W/ Ø3/4"

INTERNALLY THREARED EXPANSION

ANCHOR (1 1/4" O.D. X 2 3/4" LONG)

DATA SIGN

DISPLAY

SCHEDULE HOLDER

"JAZZ" CUSTOM GLASS

DISPLAY

"JAZZ" CUSTOM GLASS

SCHEDULE HOLDER

3/16" POLYCARBONATE LENS

4" SCH 80 (316) STN STL SCH 80 PIPE

180 GRIT BRUSHED FINISH

6 7/16" CLEARANCE

7'

- 1

/8 " T

O

RA

DI

US

7' -1

5/

8" T

O

CO

LU

M

N 8'

-2

/8 " M

IN

. C

LE

AR

AN

CE

A T

FR

ON

T

8' -1

3/

4" O

/A H

EI

GH

T

4' -8

" R

OO

F

24'-4" ROOF

1/

2" T

YP

11'-0" C/C COLUMNS

REAR FRAME, 2" X 2" X 3/16" W.T.

ALUMINUM TUBING

CAMERA LOCATIONS

CAMERA LOCATION

SPECO D4WRSP

POWER SUPPLYELECTRICAL SERVICE HERE

CAMERA LOCATION

GENERAL NOTES:

1. ALL STRUCTURAL STEEL, UNLESS OTHERWISE NOTED, SHALL

BE ASTM A-36, MINIMUM YIELD STRENGTH 36,000 PSI.

2. ALL STRUCTURAL ALUMINUM MEMBERS, UNLESS OTHERWISE

NOTED, SHALL BE OF ALLOY 6063-T5 OR GREATER.

3. ALL HOLES TO BE DRILLED OR PUNCHED.

4. STEEL WELDING SHALL CONFORM TO AMERICAN WELDING

SOCIETY STANDARD D1. 1-00. ELECTRODES SHALL CONFORM

TO AWS 5.1, CLASS E70S-5.

5. ALUMINUM WELDING SHALL CONFORM TO AMERICAN

WELDING SOCIETY STANDARD D1. 2-08. ELECTRODES SHALL

CONFORM TO AWS/SFA 5.10 CLASS ER4043.

6. ALL WELDING TO BE DONE AT TOLAR MANUFACTURING

COMPANY, INC. FACILITY.

11'-0" C/C COLUMNS

4'-8" 5 25/32"

1'-9 5/8"

2'-9 5/8"

11'-0"

4'- 1/8"

5/8" OFFSET (TYP.)

3'-9" 3'-2 7/8" 3'-2 7/8" 3'-9" 4'- 1/8"

11'-0"

GLASS SUPPORTS

FLOOR / FOUNDATION PLAN

30" X 30" X 24" DEEP

PAD FOOTINGS PER

FOUNDATION PLAN

SHELTER ROOF ABOVE

File details come from the government source that posted it. Updated .