RFQ 19N06024Q0004 Amendment Number P0002- Revised SOW (F).pdf

PDF 3 MB Posted

Attached to
Residential Exterior Lighting Project
Solicitation number
19N06024Q0004
Issued by

About this file

This document is an Amendment (Amendment Number P0002) to a Request for Quotation (RFQ 19N06024Q0004) for a Residential Exterior Lighting Project at the U.S. Embassy in Oslo, Norway.

The key details are:

  • The solicitation due date has been extended to 16:00 local time on May 15, 2024.
  • The scope of work requires the installation of residential exterior lights, including 10 facade lights, 17 walkway lights, and 2 light poles with lights. All electrical cables must be in underground conduit, and the work must be performed in accordance with Norwegian Electrical Codes (NEK 400).
  • The magnitude of the project is anticipated to be between $25,000 and $100,000 U.S. Dollars.
  • Firms must be knowledgeable in written and spoken English, authorized to operate and do business in Norway, and registered in the SAM (System for Award Management) Database.
  • The solicitation and award will be subject to the laws and regulations of the United States of America, and the requirement is being competed utilizing full and open competition procedures.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Embassy of the United States of America

Oslo, Norway

April 30, 2024

Solicitation number 19N06024Q0004 – Amendment Number P0001

Residential Exterior Lighting Project

The following sections of the above solicitation have been amended as follows:

Section A – SF 1442 – Cover Sheet:

Line number 13A due date for submission of bids is extended to 16:00 local time May 15, 2024.

C.4.1 Lighting Fixtures – paragraph two:

The contractor is requested to install residential exterior lights. All electrical cables must be in underground conduit. All wall-mounted conduits must be steel pipe. Wall-mounted cables to lights fixtures, must be from ground and up. The conduits must be buried minimum 0.50m under the surface. Pull boxes shall be installed wherever it is necessary. The contractor is responsible to locate existing underground utilities to avoid cut and disruption. Tree roots should be avoided to minimize any damages. All length of conduits must be marked with detectable underground utility tape. All the work must be performed in accordance with Norwegian Electrical Codes, NEK 400.

C.5 Technical Specifications:

C.5 TECHINICAL SPECIFICATIONS:

The service should include:

• Installation of:

• 10 Façade Lights: Wall luminaires · BEGA

• 31 072 K3 Graphite 3000K Wall Luminaire

• 17 Walkway Lights: BEGA Light Bollards

• 84 063 K3 Graphite 3000K Pullertarmatur

• 2 Light Poles with lights: Light Building Elements · BEGA

• 84 875 K3 Graphite 3000K Light Building Element

References:

National Park Service Brief #17:

https://www.nps.gov/tps/how-to-preserve/briefs/17-architectural-character.htm National Park Service Brief #36:

https://www.nps.gov/tps/how-to-preserve/briefs/36-cultural-landscapes.htm https://www.nps.gov/tps/how-to-preserve/briefs/17-architectural-character.htm https://www.nps.gov/tps/how-to-preserve/briefs/36-cultural-landscapes.htm

PART III - LIST OF DOCUMENTS, EHIBITS AND OTHER ATTACHMENTS

SECTION J – LIST OF ATTACHMENTS

ATTACHMEN

T NUMBER DESCRIPTION OF ATTACHMENT

NUMBER OF

PAGES

Attachment 1 Drawings 10

ATTACHMENT # 1 - DRAWINGS

Suggestion Only. Red dots: 17 Walkway light fixtures along the driveways, on south side and west side of the building. Blue dots: 10 façade Light fixtures. Yellow dots: 2 Light poles for gates.

2 façade lights mounted approx. 250cm from the ground and approx. 60cm from edge of the wall on both sides.

1 façade light mounted approx. 250cm from the ground and approx. 60cm from edge of the window.

2 façade lights mounted approx. 150cm from the roof and approx. 60cm from edge of the walls.

2 façade lights mounted approx. 150cm from the roof. 1 light on the center between windows and the other one with the same distance to the window.

2 façade lights mounted approx. 150cm from the roof and approx. 60cm from edge of the wall.

4 Walkway lights with an approx. 4m distance. No façade lights.

4 Walkway lights with an approx. 4m distance.

1 façade light replacing the existing wall-mounted light on the same location.

Generic image. Walkway illumination.