NOTIFIER FIRE ALARM SYSTEM SPARES - NCP.pdf
PDF 1 MB Posted
- Attached to
- MEX-NEC NOTIFIER SPARES FOR FIRE ALARM SYSTEMS Federal contract opportunity
- Solicitation number
- 19MX5326Q0053
- Issued by
- Department of State US Embassy Mexico
About this file
This is a Single Source Justification for a simplified acquisition from the Department of State's Overseas Post Mexico City to procure Original Equipment Manufacturer (OEM) NOTIFIER spare parts for the New Embassy Compound (NEC) fire alarm system. The estimated procurement value is $39,214.00 USD. The contracting activity is the General Services Office (GSO), with the Facility Management Office (FAC) as the requiring activity under request PR16075966. The justification cites brand-name authority under FAR 13.106-1(b)(1) as the statutory basis for single-source procurement, as the fire alarm system is a proprietary NOTIFIER life-safety system purpose-built with NOTIFIER components throughout its design, programming, testing, and commissioning stages.
The spare parts list includes seventeen NOTIFIER components: FPTI-951 multi-criteria smoke detector, FSP-951R duct smoke detector, FST-951R heat detector, NBG-12LX pull station, FRM-1 relay module, FMM-1 monitor module, FDM-1 dual monitor, LCM-320 loop control module, LEM-320 loop expander module, HS-NCM-MF network communication module, CPS-24 power supply, ACPS-610 addressable charger/power supply, DNR duct detector casing, SRL wall strobe, and PC2WL ceiling horn strobe. The justification emphasizes that only OEM NOTIFIER parts can maintain system compatibility, configuration integrity, and manufacturer support. The Government determined that introducing non-OEM components would disrupt the integrated system architecture, potentially void warranties, create delays through costly reconfiguration and third-party testing, and compromise critical life-safety functions. The Contracting Officer Morgan Osborne certified that the anticipated cost is fair and reasonable, and Facility Manager David Marshall certified the accuracy of the requirements submission on July 8, 2026.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SINGLE SOURCE JUSTIFICATION NOT EXCEEDING THE SIMPLIFIED ACQUISTION
THRESHOLD
SECTION 1: IDENTIFICATION OF THE AGENCY AND THE CONTRACTING ACTIVITY
Department of State Contracting Activity
☐ Office of Acquisitions Management
☐ Foreign Service Institute
☐ Office of Foreign Missions
☐ U.S. Mission to the United Nations ☒ Overseas Post Mexico City
Requiring Activity PR16075966 - MEX/FAC/7112/NEC/SPARE/NOTIFIER fire system spares
SECTION 2: NATURE AND/OR DESCRIPTION OF THE ACTION BEING APPROVED
FAC requires approval for the procurement of Original Equipment Manufacturer (OEM) NOTIFIER spare parts on a brand-name basis. These spare parts are required for the NEC fire system.
SECTION 3: DESCRIPTION OF SUPPLIES/SERVICES REQUIRED TO MEET THE AGENCY’S NEEDS
FAC requests approval to procure Original Equipment Manufacturer (OEM) NOTIFIER spare parts for the fire alarm system at the New Embassy Compound (NEC) on a brand-name basis.
OBO has reviewed and approved the attached spare parts list and directed that replacement components be limited to the specified NOTIFIER models to maintain system compatibility, configuration integrity, and manufacturer support. Replacement components must be fully compatible with the installed system architecture.
The estimated value of this procurement is $39,214.00 USD. All replacement parts must match the brand and model of the originally installed equipment to ensure compatibility with the existing fire alarm system, maintain critical life-safety functions, and preserve manufacturer warranties. Maintaining this inventory will enable the
FAC team to perform expedited component replacements, minimizing service disruptions and ensuring continuity of Embassy operations.
Brand name Part # Model Item description
Notifier FPTI-951 FPTI-951 SMOKE DETECTOR MULTI-CRITERIA Notifier FSP-951R FSP-951R SMOKE DETECTOR FOR DUCT Notifier FST-951R FST-951R HEAT DETECTOR Notifier NBG-12LX NBG-12LX PULL STATION Notifier FRM-1 FRM-1 MODULE RELAY Notifier FMM-1 FMM-1 MONITOR MODULE Notifier FDM-1 FDM-1 DUAL MONITOR
Notifier LCM-320 LCM-320 LOOP CONTROL MODULE Notifier LEM-320 LEM-320 LOOP EXPANDER MODULE Notifier HS-NCM-MF HS-NCM-MF NETWORK COMUNICATION MODULE Notifier CPS-24 CPS-24 POWER SUPPLY Notifier ACPS-610 ACPS-610 ADDRESSSABLE CHARGER/POWER SUPPLY Notifier DNR DNR DUCT DETECTOR (CASING) Notifier SRL SRL WALL STROBE Notifier PC2WL PC2WL CEILING HORN STROBE
SECTION 4: IDENTIFICATION OF THE STATUTORY AUTHORITY PERMITTING OTHER THAN
FULL AND OPEN COMPETITION
In accordance with Federal Acquisition Regulation (FAR) 13.106-1(b)(1), the Contracting Officer has deemed only one source reasonably available based on the following:
☐ Urgency
☐ Exclusive licensing agreements
☒ Brand-name
☐ Industrial mobilization
☐ Other: Vendor
SECTION 5: DEMONSTRATION THAT THE PROPOSED CONTRACTOR’S UNIQUE
QUALIFICATIONS OR THE NATURE OF THE ACQUISITION REQUIRES USE OF THE AUTHORITY
CITED
The NEC fire alarm system is a proprietary NOTIFIER life-safety system that was purpose-built using NOTIFIER components at every stage — from design and programming through testing and commissioning. This end-to-end integration means that every element of the system, including its software configurations, communication protocols, and hardware interfaces, was engineered to function as a unified NOTIFIER ecosystem. The requested spare parts are OEM replacement components specifically manufactured to operate within this installed system architecture. Introducing non-OEM components would disrupt this carefully engineered compatibility, potentially requiring costly system reconfiguration, additional third-party testing, and re-certification — all of which introduce delays, financial exposure, and unacceptable risk to a critical life-safety system. Furthermore, the use of non-OEM parts may void existing manufacturer warranties, leaving the Government without recourse in the event of system failure and compounding long-term operational costs.
Maintaining a sufficient inventory of OEM NOTIFIER spare parts is not merely a logistical preference — it is an operational necessity. When components fail in a life-safety system, the ability to respond quickly and restore full functionality is paramount. Without readily available OEM parts, FAC technicians face extended lead times, sourcing uncertainty, and the risk of prolonged system downtime that could leave personnel and facilities without adequate fire protection. An on-hand inventory of certified NOTIFIER replacement components ensures that technicians can execute timely repairs with confidence, preserving the continuity of critical life-safety functions and maintaining compliance with applicable safety regulations. Accordingly, the Government has determined that only OEM NOTIFIER replacement parts can satisfy the agency's minimum technical, safety, and operational requirements — and that procuring these parts represents the most responsible and cost-effective path forward.
SECTION 6. DETERMINATION BY THE CONTRACTING OFFICER THAT THE ANTICIPATED COST
TO THE GOVERNMENT IS FAIR AND REASONABLE
By signing the justification, the Contracting Officer makes a determination that the price to the Government is anticipated to be fair and reasonable.
SECTION 7. CERTIFICATIONS
All reviews and approvals should be completed in the order listed unless otherwise authorized or required.
REQUIREMENTS CERTIFICATION
I certify that the facts and representations under my cognizance which are included in this Justification and its supporting acquisition planning documents, except as noted herein, are complete and accurate to the best of my knowledge and belief.
Requirements Cognizance:
SIGNATURE:
David Marshall Date Facility Manager Facility Management Office (FAC)
CONTRACTING OFFICER CERTIFICATION
I certify that this submission is accurate to the best of my knowledge, and that it contains complete information necessary to enable other officials to make an informed recommendation for approval or disapproval.
SIGNATURE:
Morgan Osborne Date Contracting Officer General Services Office (GSO)
07/08/2026 14:40 GMT