Appendix 1 - Architectural Plans 1 (1).pdf

PDF 2 MB Posted

Attached to
CGR Interior Painting and Repairs
Solicitation number
19M03027Q0004
Issued by

About this file

This document is a set of architectural drawings depicting the existing conditions of the U.S. Consul General Residence in Casablanca, Morocco, prepared by A359 Partners in Architecture as of September 18, 2026. The package includes thirteen sheets at 1:100 scale showing floor plans, reflected ceiling plans, elevations, and sections. The drawings document the basement, ground floor, and upper level layouts with detailed notation of existing conditions including moisture damage, cracking, loose plaster, corroding railings, pitted marble, and water damage throughout the structure. Door and window types are classified by material (steel, wood, aluminum) and configuration, while floor finishes include ceramic tile, marble, concrete, terrazzo, stone, brick, flagstone, and cement tile. Ceiling materials consist of ceramic tile, surface-applied plaster, suspended plaster, and painted concrete, with lighting fixtures including recessed cans, surface-mounted wall sconces, chandeliers, pendants, and linear lights.

The building encompasses a basement level at -2.44 meters, ground floor at 0.00 meters, upper floor at 3.99 meters, terrace at 8.10 meters, and parapet heights ranging from 8.60 to 9.28 meters. Key spaces include a staff area with bedrooms and utilities, living and dining rooms, kitchen, offices, foyer, patio, and multiple toilets throughout. Exterior elevations reveal security grilles, insect screens, downspouts, pipe scuppers, wood lattice elements, light fixtures, awnings, and cable molding. The roof plan identifies scuppers, collector heads, ladder and cage access, flood lights, antennae, satellite dishes, and vent stacks. Notable structural observations include concrete pavers on the roof with minimal gaps to the parapet wall and roof slopes assessed visually without water testing. The drawings serve as an existing conditions survey to inform restoration or renovation planning for the federal diplomatic property.

View the file

Other files

File Type Posted
SOW CGR Maintenace Repair.docx DOCX document
SF18.pdf PDF
19M03027Q0004-CGR Interior repairs and Painting-RFQ.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STAFF

BEDROOM 2

STAFF

BEDROOM 1

GARAGE

TOILET

LAUNDRY

PANTRY

STORAGE

IT ROOM

J

EE

A

A

A

F

F F

F

F F

B

B B

D

C

DOOR AND WINDOW TYPES

A. STEEL DOOR

B. FLUSH WOOD DOOR

C. WOOD DOOR WITH GLAZING

D. WOOD FRAMED WINDOW

E. ALUMINUM FRAMED WINDOW W STEEL GRILLE

F. WOOD SLAT DOOR

H. SECTIONAL OVERHEAD GARAGE DOOR

J. EGRESS LITE

SHEET KEY NOTES

1. ELECTRIC EQUIPMENT.

2. OPENING IN FLOOR

3. MOISTURE IN WALL (DASHED LINE).

4. WALL OPENING INFILL W BLOCK.

5. BOARDED-UP WINDOW.

6. RAISED FLOOR.

7. MECHANICAL/PLUMBING EQUIPMENT.

8. IRRIGATION ADJACENT TO FOUNDATION.

SHOWER

HALL

UTILITY

ROOM

XX

XX

A2021

A203

A204 1

A201

H

J E

E E

STOR.

A206

A205

5D

21.03 m

.5 m

OUTLINE OF GROUND

FLOOR ABOVE

WH

B

WH

WH

2WH W DW

W

STAIR

STAIR

STAIR 3

STAIR

CERAMIC TILE

CONCRETE W/ EPOXY COATING

CERAMIC TILE (BALCONIES)

MARBLE TILE (STAIRS)

FLOOR FINISH LEGEND

CERAMIC TILE (BATHROOMS)

TERRAZZO

STONE (HALLS)

MARBLE TILE (GRID PATTERN)

BRICK

FLAGSTONE

CONCRETE

CEMENT TILE

A359 PARTNERS IN ARCHITECTURE A101

18 SEP 2026

BASEMENT PLANUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

1:100 SCALE (PRINTED 11"X17")

0 1m 5m 10m

LIVING

ROOM

DINING

ROOM

KITCHEN

MAP

ROOM

TOILET

OFFICE

FOYER

D

D

A

E

PATIO

DOOR AND WINDOW TYPES

A. STEEL DOOR

B. FLUSH WOOD DOOR

C. WOOD DOOR WITH GLASS

D. WOOD WINDOW

E. ALUMINUM WINDOW

F. WOOD SLAT DOOR

G. SLIDING FLUSH DOOR

SHEET KEY NOTES

1. PITTED AND LOOSE MARBLE.

2. CRACKED MARBLE.

3. HEAVING MARBLE FLOOR.

4. BRICK APRON ON GRADE.

5. INFILLED/REDUCED WINDOW OPENING.

6. RECESSED RADIATOR AND GRILLE.

7. IRRIGATION ADJACENT TO FOUNDATION.

A

A

B

C

C

B

B

D D

D

XX

XX

DD

C

D

D

E

A2021

A203

A204 1

A201

E

STAIR

A206

A205

B

B

F G

F

G

B

12.84 m 8.11 m

.4 m

2.

m 3.

m

FIREPLACE

FOUNTAIN

HALL

6 6

STAIR

STAIR

STAIR

STAIR

CERAMIC TILE

CONCRETE W/ EPOXY COATING

CERAMIC TILE (BALCONIES)

MARBLE TILE (STAIRS)

FLOOR FINISH LEGEND

CERAMIC TILE (BATHROOMS)

TERRAZZO

STONE (HALLS)

MARBLE TILE (GRID PATTERN)

BRICK

FLAGSTONE

CONCRETE

CEMENT TILE

A359 PARTNERS IN ARCHITECTURE A102

18 SEP 2026

GROUND FLOOR PLANUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

TOILET 3TOILET

TOILET

TOILET

TOILET 4

TOILET

OFFICE

DOOR AND WINDOW TYPES

A. STEEL DOOR.

B. FLUSH WOOD DOOR.

C. WOOD DOOR WITH GLASS.

D. WOOD WINDOW.

E. ALUMINUM WINDOW.

F. WOOD SLAT DOOR.

G. SAFE DOOR.

D

C

G

D

D

C

D

C

D

B

B

B

B

B

B

C

B

B

C

C

B

B

B B B

D

B

D

D

B

SHEET KEY NOTES

1. CRACKED CONCRETE COPING.

2. RAISED FLOOR AT SHOWER.

3. CRACKING.

4. PEELING PAINT.

5. CORRODING AT RAILING SUPPORTS.

6. MOISTURE AT INSIDE FACE OF

BALLUSTRADE.

7. PAINTED ROOF COATING.

8. DOWNSPOUT.

9. SCUPPER PIPE.

10. VINYL AWNING.

4 5

1 6

F

F F

F F

F

F

B

F

XX

XX

A2021

A203

A204 1

A201

A206

A205

OPEN TO

BELOW

12.33 m 8.61 m

1.13 m

11.06 m

2.20 m

3.20 m

STAIR

CERAMIC TILE

CONCRETE W/ EPOXY COATING

CERAMIC TILE (BALCONIES)

MARBLE TILE (STAIRS)

FLOOR FINISH LEGEND

CERAMIC TILE (BATHROOMS)

TERRAZZO

STONE (HALLS)

MARBLE TILE (GRID PATTERN)

BRICK

FLAGSTONE

CONCRETE

CEMENT TILE

A359 PARTNERS IN ARCHITECTURE A103

18 SEP 2026

UPPER LEVEL PLANUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

SLOPESLOPE

SL

OP

E

SHEET KEY NOTES

1. SCUPPERS.

2. COLLECTOR HEADS.

3. LADDER AND CAGE.

4. FLOOD LIGHT, TYPICAL

5. ANTENNAE

6. VENT STACK

7. SATELLITE DISH

8. SCUPPER CALLED OUT ON 2023

ROOF RENOVATION PLAN;

COLLECTOR HEAD NOT VISIBLE.

9. RAISED ENCLOSURE, PRESUMED

VENT STACK; INTERIOR NOT

VISIBLE.

0.10 m

0.10 m

0.

m

0.05 m

0.05 m

0.

m3

XX

A2021

A203

A204 1

A201

A206

A205

CONCRETE PAVERS, TYPICAL

DIMENSION OF GAP

BETWEEN PAVERS AND

PARAPET WALL, TYP.

0.

m

GENERAL NOTES:

ROOF SLOPES BASED ON VISUAL

ASSESSMENT; WATER TESTS

WERE NOT PERFORMED.

1.

m

.4 m 2.

m

9.18 m12.23 m

A359 PARTNERS IN ARCHITECTURE A104

18 SEP 2026

ROOF PLANUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

SHEET KEY NOTES

1. MOISTURE IN CEILING.

2. LOOSE PLASTER

3. EXPOSED REBAR

XX2

XX

A2021

A203

A204 1

A201

2.56m 2.56m

2.56m

2.56m

2.04m

2.04m

2.04m

2.04m

2.04m

2.04m

A206

A205

CEILING MATERIAL

HATCH LEGEND

CERAMIC CEILING TILE

SURFACE APPLIED PLASTER

PAINTED CONCRETE

SUSPENDED PLASTER

FAN

SURFACE MOUNTED

WALL SCONCES

CHANDELIER/PENDANT

LIGHTING LEGEND

LINEAR LIGHT

RECESSED CAN

A359 PARTNERS IN ARCHITECTURE A111

18 SEP 2026

BASEMENT REFLECTED CEILING PLANUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

1. MOISTURE IN CEILING.

2. CRACKS IN PLASTER.

XX

A2021

A203

A204 1

A201

3.6m

3.55m3.55m

2.75m2.75m

2.9m

3.65m

2.95m 3.6m

3.6m

3.1m

A206

A205

AWNING

CEILING MATERIAL

HATCH LEGEND

CERAMIC CEILING TILE

SURFACE APPLIED PLASTER

PAINTED CONCRETE

SUSPENDED PLASTER

FAN

SURFACE MOUNTED

WALL SCONCES

CHANDELIER/PENDANT

LIGHTING LEGEND

LINEAR LIGHT

RECESSED CAN

A359 PARTNERS IN ARCHITECTURE A112

18 SEP 2026

GROUND FLOOR REFLECTED CEILING PLANUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

A2021

A203

A204 1

3.4m

2.5m

2.65m

2.5m

3.25m2.45m 3.45m

2.7m

3.4m

3.4m 3.4m

3.4m 3.4m

3.4m

3.25m

2.7m 2.65m

3.3m

3.3m

3.3m

2.85m

2.5m

3.3m

A206

A205

SHEET KEY NOTES

1. MOISTURE IN CEILING.

2. CRACKS IN PLASTER.

XX

1 2

1 2

CEILING MATERIAL

HATCH LEGEND

CERAMIC CEILING TILE

SURFACE APPLIED PLASTER

PAINTED CONCRETE

SUSPENDED PLASTER

FAN

SURFACE MOUNTED

WALL SCONCES

CHANDELIER/PENDANT

LIGHTING LEGEND

LINEAR LIGHT

RECESSED CAN

A359 PARTNERS IN ARCHITECTURE A113

18 SEP 2026

UPPER LEVEL REFLECTED CEILING PLANUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

1. INSECT SCREEN

2. SECURITY GRILL.

3. DOWNSPOUT.

4. PIPE SCUPPER.

5. WOOD LATTICE.

6. COLLECTOR HEADS.

7. LIGHT FIXTURE.

8. AWNING.

9. CABLE MOLDING.

DOOR AND WINDOW TYPES

A. STEEL DOOR.

B. WOOD PANEL DOOR.

C. WOOD DOOR WITH GLASS.

D. WOOD WINDOW.

E. ALUMINUM WINDOW.

F. WOOD SLAT DOOR.

G. SAFE DOOR.

XX

XX

C

D

C C

D D A D DD

4 4

1 2

2 2 2

15 1

A206

TYP.

A359 PARTNERS IN ARCHITECTURE A201

18 SEP 2026

SOUTH ELEVATIONUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

2. SECURITY GRILL.

3. DOWNSPOUT.

4. LIGHT FIXTURE.

5. CABLE MOLDING.

6. ELECTRICAL BOX.

1 12 2

DOOR AND WINDOW TYPES

A. STEEL DOOR.

B. WOOD PANEL DOOR.

C. WOOD DOOR WITH GLASS.

D. WOOD WINDOW.

E. ALUMINUM WINDOW.

F. WOOD SLAT DOOR.

G. SAFE DOOR.

C XX

XX

D D

A A

D D

5 4

A205

TYP.

A359 PARTNERS IN ARCHITECTURE A202

18 SEP 2026

EAST ELEVATIONUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

2. SECURITY GRILL.

3. DOWNSPOUT.

4. PIPE SCUPPER.

5. WOOD LATTICE.

6. COLLECTOR HEADS.

7. LIGHT FIXTURE.

8. AWNING.

9. CABLE MOLDING.

10. LADDER AND CAGE.

11. CONDENSER.

12. EXHAUST FAN.

13. CABLE.

14. WATER DAMAGE.

15. ANTENNA

DOOR AND WINDOW TYPES

A. STEEL DOOR.

B. WOOD PANEL DOOR.

C. WOOD DOOR WITH GLASS.

D. WOOD WINDOW.

E. ALUMINUM WINDOW.

F. WOOD SLAT DOOR.

G. SAFE DOOR.

XX

XX

D D D

C C D

D D

DD

E E E E E

C

1 1

1 2

1 2

1 2

A206

TYP.

A359 PARTNERS IN ARCHITECTURE A203

18 SEP 2026

NORTH ELEVATIONUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

2. SECURITY GRILL.

3. DOWNSPOUT.

4. PIPE SCUPPER.

5. WOOD LATTICE.

6. COLLECTOR HEADS.

7. LIGHT FIXTURE.

8. AWNING.

9. CABLE MOLDING.

10. LADDER AND CAGE.

11. CONDENSER.

12. EXHAUST FAN.

13. CABLE.

14. WATER DAMAGE.

15. ORIGINAL WINDOW

OPENING REDUCED.

DOOR AND WINDOW TYPES

A. STEEL DOOR.

B. WOOD PANEL DOOR.

C. WOOD DOOR WITH GLASS.

D. WOOD WINDOW.

E. ALUMINUM WINDOW.

F. WOOD SLAT DOOR.

G. SAFE DOOR.

H. GARAGE DOOR

XX

XX

6 6

D

E E

A

E

D

9 D

H

A205

A359 PARTNERS IN ARCHITECTURE A204

18 SEP 2026

WEST ELEVATIONUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

Basement -2.44 m

Ground Flr

0.00 m

Upper Floor

3.99 m

Terrasse

8.10 m

Parapet high

9.28 m

Parapet Low

8.60 m

A206

3.

m

3.

m

2.

m

2.

m

3.

m

3.

m

3.

m

A359 PARTNERS IN ARCHITECTURE A205

18 SEP 2026

SECTION AUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

Basement -2.44 m

Ground Flr

0.00 m

Upper Floor

3.99 m

Terrasse

8.10 m

Staff -2.97 m

Parapet high

9.28 m

A205

3.

m

3.

m

2.

m

3.

m

3.

m

A359 PARTNERS IN ARCHITECTURE A206

18 SEP 2026

SECTION BUS CONSUL GENERAL RESIDENCE, CASABLANCA - EXISTING CONDITIONS

A101 - BASEMENT PLAN
A102 - GROUND FLOOR PLAN
A103 - UPPER LEVEL PLAN
A104 - ROOF PLAN
A111 - BASEMENT REFLECTED CEILING PLAN
A112 - GROUND FLOOR REFLECTED CEILING PLAN
A113 - UPPER LEVEL REFLECTED CEILING PLAN
A201 - SOUTH ELEVATION
A202 - EAST ELEVATION
A203 - NORTH ELEVATION
A204 - WEST ELEVATION
A205 - SECTION A
A206 - SECTION B

File details come from the government source that posted it. Updated .