This document is a comprehensive architectural and technical design specification for a 40-foot shipping container converted into an office space (PCI Type), prepared by the U.S. Embassy in Guatemala in April 2022. The specification includes detailed floor plans, elevations, cross-sections, and construction details at scales of 1:75 and 1:25.

The container office space is divided into functional zones: office area, rest area, meeting/eating area, and storage area. Key components include an air conditioning system (24,000 BTU minisplit with evaporator and condenser units), electrical infrastructure with a 70-amp 2-space circuit load center and multiple 220V outlets, LED lighting throughout, and suspended acoustic ceiling with mineral fiber panels. The office area contains a desk, computer, multifunction printer, scanner, and filing cabinet. The meeting area includes a table and plastic chairs, while the rest area features a cold/hot water dispenser. Exterior security includes fixed security grills on windows and swing security grills on door openings. The container is fixed to a reinforced concrete base with specific drainage and anchoring requirements. All welded points must be polished and painted with anticorrosion primer and light gray oil paint (Pantone Cool Gray 7C). The design specifies white enameled galvanized materials, PVC windows and profiles, and detailed electrical installation diagrams for lighting and power distribution. Access is provided via metal steps with antipanic push bar doors meeting UL and ANSI grade 1 standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE

INDICATED

DRAWING

APRIL 2022

Es/Je

UNIDOS EN GUATEMALA

APLICACIÓN DE LA LEY (INL)

EMBAJADA DE LOS ESTADOS

SECCIÓN DE ASUNTOS ANTINARCOTICOS Y

PLAN No.

FROM

PROJECT

DATE ADDRESS

DESIGN

Julio Hernández Santizo Col.982

Arq.

PLAN

40' C ontainer PC

I Type

40ft S hipping C ontainer - O utside of the road

C C

TV 50" TV screen fixed to w all Floor Plan

Low open shelves

(by others)

C old/hot w ater dispenser (by others)

Plastic table (Ø

0.90 +

4 plastic chairs (by others))

W aiting chairs

(by others)

M ultifuncional Printer plastic resin desk w ith

1.82x0.75x0.74 folding legs

C om puter Scanner

O ffice C hair w ith w heels

9U W all M ount R ack Enclosure Server C abinet

M etal open shelves

0.93x0.30x2.00 (250 lb/shelf)

Floor Plan +

40' Sea Container for Office space (PCI Type)

Dimensioned Floor Plan

S cale 1:75

A B

C

1 2

40' C ontainer PC

I Type

40ft S hipping C ontainer - O utside of the road

S cale 1:75

A B

C

1 2

0.09 0.150.90

0.66 2.00

4.56 2.00

1.78 0.02

12.16

0.02 2.40 0.02

2.44

0.210.901.33

0.12 1.23

1.70 2.00

4.56 2.00

0.25

2.25 0.25 2.00

4.56 2.00

1.70 0.05

1.38

2.36

0.13 0.900.35 s=0.90 d=1.80 s=0.90 d=1.80 s=0.90 d=1.80 s=0.90 d=1.80 d=2.10 d=2.10

O riginal C ontainer doors not to be used but rem ain funcional

D im ensioned Floor Plan

10.51

A/C Evaporator projection

O ffice area

R est area

M eeting/eating area

S torage area willymazariegos

DRAWING

APRIL 2022

Es/Je

UNIDOS EN GUATEMALA

APLICACIÓN DE LA LEY (INL)

EMBAJADA DE LOS ESTADOS

SECCIÓN DE ASUNTOS ANTINARCOTICOS Y

PLAN No.

FROM

PROJECT

DATE ADDRESS

DESIGN

Julio Hernández Santizo Col.982

Arq.

PLAN

R ight Elevation - 40' C ontainer Type PC

I

R oof Elevation - 40' C ontainer Type PC

I

Left Elevation - 40' C ontainer

Type PC I

A B

C

1 2

A B

C

1 2

A B

C

1 2

A/C C ondenser U nit (placed over

N eoprene strips to reduce vibration)6.14

40ft S hipping C ontainer - O utside of the road

0.88 0.05

0.90 0.05

0.46 reinforcem ent square 2" tube gauge 14

1.75 0.05

2.00 0.05

4.46 0.05

2.00 0.05

1.72 fixed security grill

0.30

0.30 reinforced concrete base

2.89

1.75 0.05

2.00 0.05

4.46 0.05

2.00 0.05 0.55

0.050.90 0.252.10

0.05 0.24 sw ing security grill m etal steps reinforcem ent square 2" tube gauge 14fixed security grill

40' Sea Container for Office space (PCI Type)

Elevations (1)

LED

100W reflector

**All exterior sides of the container to be painted w ith 2 hands of anticorrosion paint, and 2 hands of light gray oil paint. (Pantone C ool gray 7C

**All w elded point m ust be polished to obtain a sm ooth finish all over.

DRAWING

APRIL 2022

Es/Je

UNIDOS EN GUATEMALA

APLICACIÓN DE LA LEY (INL)

EMBAJADA DE LOS ESTADOS

SECCIÓN DE ASUNTOS ANTINARCOTICOS Y

PLAN No.

FROM

PROJECT

DATE ADDRESS

DESIGN

Julio Hernández Santizo Col.982

Arq.

PLAN

B ack Elevation (no changes)

Front Elevation

0.050.90 0.252.10

0.05 0.27 sw ing security grill m etal steps

1.33

0.170.30 reinforced concrete base reinforced concrete base

2.44

2.59 0.30

0.30

0.90 0.90 0.51 0.09

34 " fiber cem ent board over existing container floor+ vinyl floor and baseboard

34 " fiber cem ent board over existing container floor+ vinyl floor and baseboard

2.31 2.23 2" foam board insulation or sim ilar

M ineal fiber suspended ceiling dryw all panel

(hum idity resistant) reinforced concrete base

S cale 1:75

40' C ontainer PC

I Type

S cale 1:75

40' C ontainer PC

I Type S ectin B

-B

S ection A

-A

S cale 1:75

40' C ontainer PC

I Type

S cale 1:75

40' C ontainer PC

I Type

PVC

w indow fixed security grill

M ineal fiber suspended ceiling dryw all panel

(hum idity resistant) reinforced concrete base

40' Sea Container for Office space (PCI Type)

Elevations (2) + Cross sections

**All exterior sides of the container to be painted w ith 2 hands of anticorrosion paint, and 2 hands of light gray oil paint. (Pantone C ool gray 7C

**All w elded point m ust be polished to obtain a sm ooth finish all over.

DRAWING

APRIL 2022

Es/Je

UNIDOS EN GUATEMALA

APLICACIÓN DE LA LEY (INL)

EMBAJADA DE LOS ESTADOS

SECCIÓN DE ASUNTOS ANTINARCOTICOS Y

PLAN No.

FROM

PROJECT

DATE ADDRESS

DESIGN

Julio Hernández Santizo Col.982

Arq.

PLAN

40' C ontainer PC

I Type

G alvanized rigid conduit L=1.00m

"accesorio de entrada"

70 am p 2-space circuit outdoor M ain Lug Load C enter, w ith 50 am p 2-pole circuit breaker + ground connection (AW G

10 green to 5/8" x 2.40m copper ground rod)

1B

2B

3B 5B

6B 7B 8B

9B

8 circuit Indoor Load C enter, h=1.30

2.05 2.70

0.55

1D

40ft S hipping C ontainer - O utside of the road

(220V) A/C C ondenser U nit

+returns to evaporator unit

0.10 D

ouble polarized and grounded outlet for w all m ounted netw ork rack h=2.00m

2.88

4B

2.88

1C

Electricity - Force 9U

W all M ount R ack

Enclosure Server C abinet

Electrical Installation

40' Sea Container for Office space (PCI Type)

S cale 1:75

A B

C

1 2

2C

1.12 h=1.50

1-2-3-4 A

40' C ontainer PC

I Type

G alvanized rigid conduit L=1.00m

"accesorio de entrada"

70 am p 2-space circuit outdoor M ain Lug Load C enter, w ith 50 am p 2-pole circuit breaker + ground connection (AW G

10 green to 5/8" x 2.40m copper ground rod)

1A 2A

3A 4A

8 circuit Indoor Load C enter, h=1.30

40ft S hipping C ontainer - O utside of the road

1.65

1.13

2.40 2.40

2.40 1.66

T8 Tw in tube LED tube vapor tight lam p, 2x18W , IP65, surface m ounted

Electricity - Lighting S cale 1:75

A B

C

1 2

0.571.130.55

D ouble polarized and grounded outlet, B ticino D om ino or sim ilar, w hite color

220 V outlet, Eagle or sim ilar, plastic plate.

Load center, 1 phase, 8 circuit, 3 lines 70A

2-space circuit outdoor M ain Lug Load C enter w ith , 1 2x50 breaker.

The entire installation m ust be hidden and channeled in 3/4" PV C electrical conduit, rigid or flexible.

6.10

5A

6A 7A

8A

LED

100W reflector, D L, 12,000 lum en, 6,500K

, IP66 (S

ylvania P23679 or sim ilar)

LED

panel 2x4, 72w

D L, 6,480 lum en, 6,000K

, prism atic difuser (Light-Tec or sim ilar)

2x18W

, T8 LED

tubes, vapor tight lam p, surface m ounted, IP65, (Light-Tec or sim ilar)

6-7-8A

S B icino D om ino double sw itch or sim ilar

The entire installation m ust be hidden (except for 5A and 6A

) and channeled in PV C electrical conduit, rigid or flexible.

5A

0.13 5.95

5.95 0.13

1.12

AutoCAD SHX Text S

AutoCAD SHX Text S

DRAWING

APRIL 2022

Es/Je

UNIDOS EN GUATEMALA

APLICACIÓN DE LA LEY (INL)

EMBAJADA DE LOS ESTADOS

SECCIÓN DE ASUNTOS ANTINARCOTICOS Y

PLAN No.

FROM

PROJECT

DATE ADDRESS

DESIGN

Julio Hernández Santizo Col.982

Arq.

PLAN

40' C ontainer PC

I Type

A/C C ondenser U nit (placed over

N eoprene strips to reduce vibration)

A/C Evaporator U nit 24,000btu M inisplit free height below m in.2.00

40ft S hipping C ontainer - O utside of the road

A /C

Floor Plan

A/C Floor Plan +

40' Sea Container for Office space (PCI Type)

Reflected Ceiling Floor Plan

S cale 1:75

A B

C

1 2

40' C ontainer PC

I Type

40ft S hipping C ontainer - O utside of the road

S cale 1:75

A B

C

1 2

12.16

2.44

W hite enam eled steel angular W hite enam eled galvanized T-15 profile

(M R

/C

T) ASTM

A-653/A-924

M Ineral Fiber Suspended C eiling U

SG

R adar 2'x2' acoustical panel Flat w hite, SQ (2215) or sim ilar

N otes:

1.

Betw een suspended ceiling and container roof panel, Foam ular panel or m ineral fiber insulation m ust be installed, 2" R ockw ool AFB or sim ilar.

0.61

0.61

1.22

0.61 0.510.52

Lamp

Lamp

Lamp

Lamp

12 " pvc drainage (free drip)

0.10

5.25 5.25

Area w ithout suspended ceiling willymazariegos

DRAWING

APRIL 2022

Es/Je

UNIDOS EN GUATEMALA

APLICACIÓN DE LA LEY (INL)

EMBAJADA DE LOS ESTADOS

SECCIÓN DE ASUNTOS ANTINARCOTICOS Y

PLAN No.

FROM

PROJECT

DATE ADDRESS

DESIGN

Julio Hernández Santizo Col.982

Arq.

PLAN

Concrete bases layout +

40' Sea Container for Office space (PCI Type)

A C

1 2

0.40

0.30

0.60

0.30

2 U #4 G

.40+ 4 ties #3 G

40 @ 0.10

0.07

0.08

Distance to be verified according to existing ground levels

5.97 5.97

0.15 0.15

0.15 2.22

0.15

R einforced concrete B ase 40' C ontainer PC I Type

S cale 1:20

2.06

0.16 0.16

0.16 0.16

0.16 0.16

0.16 0.16

0.16 0.16

0.16 0.16

0.16

0.480.48

0.96 1/2" square m etal bar

2" x 14 " flat m etal profile

0.11 bar end w elded to w indow opening reinforcem ent

**Fixed grill to be painted w ith 2 hands of anticorrosion paint, and 2 hands of gray oil paint.

**All w elded point m ust be polished to obtain a sm ooth finish all over.

Fixed w indow grill 40' C ontainer PC I Type

S cale 1:25

Details 1

2.00

0.90

PVC

fram e fixed to w indow opening square tubing reinforcem ent w hite PVC profiles 60 series clear 5m m glass + black perforated m esh film fixed m osquito net screen

0.90

2.10

0.47 0.04

0.47 0.04

0.49 0.04

0.46 0.04 internal structure ladder type w ith square 1 12 " tube, gauge 18 exterior face w ith flat

18 " m etal sheet antipanic push bar, 1 support point, Ansi grade 1, 3 hour rated, keyed lock on the outside.

0.90 aerial hydraulic door closer Yale 3005 or sim ilar U L228, C U

L, U L10c 2 hrs., AN

SI 156.3

2x2" angle fram e w elded to door opening square tubing reinforcem ent

**D oor and fram e to be painted w ith 2 hands of anticorrosion paint, and 2 hands of gray oil paint.

**All w elded point m ust be polished to obtain a sm ooth finish all over.

0.140.610.620.610.14

1" cartdrige hinge (4 units)

1/2" square m etal bar

2" x 14 " flat m etal profile

1" cartdrige hinge (3 units)

0.481.140.48 double cylinder keyed D eadbolt Lock, satin nickel finish

0.96

2" x 14 " flat m etal profile

**Fixed grill to be painted w ith 2 hands of anticorrosion paint, and 2 hands of gray oil paint.

**All w elded point m ust be polished to obtain a sm ooth finish all over.

SCALE

INDICATED

DRAWING

APRIL 2022

Es/Je

UNIDOS EN GUATEMALA

APLICACIÓN DE LA LEY (INL)

EMBAJADA DE LOS ESTADOS

SECCIÓN DE ASUNTOS ANTINARCOTICOS Y

PLAN No.

FROM

PROJECT

DATE ADDRESS

DESIGN

Julio Hernández Santizo Col.982

Arq.

PLAN

40' Sea Container for Office space (PCI Type)

Details 2

S w ing door grill (2 units) 40' C ontainer PC I Type

S cale 1:25

M etal access door (2 units)

40' C ontainer PC

I Type S cale 1:25

PV

C S liding w indow

(4 units) 40' C ontainer PC I Type

S cale 1:25

C ontainer door edge D iam ond pattern m etal sheet (to w ithstand 350 punds)

2" L-profile structure

1" cartdridge hinge fixed to stairs and to container

1 12 " round tube on both sides

0.16

0.30

0.30

0.16

0.16

0.90

R0.20

**All parts to be painted w ith 2 hands of anticorrosive paint and 2 hands of light gray oil paint (Pantone C ool G ray 7C

0.90

M etal S teps (2 units) 40' C ontainer PC I Type

S cale 1:25

Internal V iew

External V iew

File details come from the government source that posted it. Updated .