19482 Giles County Administrative Board Room - Design-Build RFP Bridging Documents 2026-02-13.pdf
PDF 4 MB Posted
- Solicitation number
- DBB-117052
- Issued by
- Franklin County, Virginia
About this file
This is a Design-Build Request for Proposal (RFP) bridging document prepared for the Giles County Board of Supervisors in Pearisburg, Virginia, detailing the renovation of approximately 3,100 to 3,234 square feet of the former Giles County Hospital to accommodate the relocation of the county's administrative board room. The project scope includes construction of a new board room with 100+ seat capacity and dais, an executive conference room, two additional conference rooms, public toilets, and storage rooms. The renovation will feature light-gauge metal stud framing with painted gypsum wallboard, carpet tile flooring in the board room with luxury vinyl tile throughout remaining areas, solid core wood doors in hollow metal frames for interior locations and insulated galvanized hollow metal doors for exterior locations, and 24-inch by 24-inch suspended acoustical panel ceilings except in the board room where the existing ceiling will be painted. The project must comply with 2021 Virginia Existing Building Code, 2021 Virginia Construction Code, 2017 ICC/ANSI A117.1 accessibility standards, 2021 Virginia Mechanical and Plumbing Codes, 2020 NFPA 70 National Electrical Code, and 2010 ADA Standards. The building is classified as Construction Type IIB with mixed-use occupancy (Business and Assembly A-3), is fully sprinklered, and requires modifications to the existing fire sprinkler system, HVAC systems, and electrical infrastructure to serve the new floor plan layout.
The project documentation establishes that the existing building occupancy load totals 161 persons across designated spaces, with the board room accommodating the majority of occupants. The design includes ADA-compliant accessibility features throughout, including accessible lavatories with sensor-operated fixtures, accessible countertops, grab bars, and door approach clearances meeting current accessibility standards. The renovation requires selective demolition of existing partitions, HVAC equipment, and portions of exterior walls to accommodate new door openings, with all asbestos-containing materials and lead-based paints prohibited. A 1-ton ductless split system and 12.5-ton ground-mounted packaged unit with demand control ventilation, economizer, and smoke detection are specified for HVAC, along with VAV boxes with hot water reheat. New plumbing infrastructure includes ADA-compliant wall-hung lavatories with hardwired sensor faucets and floor-mounted flush valve water closets. The electrical design calls for a new 225-ampere panelboard (LA1) fed from the existing main switchboard, with lighting controls incorporating occupancy and vacancy sensors, emergency lighting, fire alarm devices matching the existing Siemens system, and television provisions throughout the space. The bridging documents were issued on February 13, 2026, as preliminary design guidance for the design-build team.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 19482 Giles County Administrative Board Room - Design-Build RFP 2026-03-16.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT DESCRIPTION:
THE GILES COUNTY BOARD OF SUPERVISORS INTENDS TO RENOVATE A PORTION OF
THE FORMER GILES COUNTY HOSPITAL TO ACCOMMODATE THE RELOCATION OF THE
COUNTY'S EXISTING ADMINISTRATIVE BOARD ROOM FROM ITS CURRENT LOCATION.
THE AREA OF RENOVATION IS APPROXIMATELY 3,100 SQ. FT. AND WILL INCLUDE THE
BOARD ROOM, EXECUTIVE CONFERENCE ROOM, TWO ADDITIONAL CONFERENCE
ROOMS, PUBLIC TOILETS, AND STORAGE ROOMS.
CODES & REGULATIONS
2021 VIRGINIA EXISTING BUILDING CODE, (VEBC)
2021 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF THE VIRGINIA UNIFORM
STATEWIDE BUILDING CODE (VUSBC)
2017 ICC/ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
2021 VIRGINIA MECHANICAL CODE
2021 VIRGINIA PLUMBING CODE
2020 NFPA 70 NATIONAL ELECTRICAL CODE
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (ADAAG)
KENTUCKY
TENNESSEE
NORTH CAROLINA
VIRGINIA
WEST
VIRGINIA
WASHINGTON
D.C.
NASHVILLE
FRANKFORT
CHARLESTON
RICHMOND
RALEIGHKNOXVILLE
CHATTANOOGA
ASHEVILLE
CHARLOTTE
ROANOKE
BLUEFIELD
TAZEWELL
ABINGDON
BRISTOL
DUFFIELD
HARLAN
NORTON
RICHLANDS
GRUNDY
PRINCETON
LEXINGTON
N
PEARISBURG
GILES COUNTY BOARD OF SUPERVISORS
PREPARED FOR
PROJECT LOCATIONPROJECT LOCATION
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
VICINITY MAP
726 Auburn Avenue
Radford, Virginia 24141
P: (540) 633-1897, F: (540) 633-1896 www.T-L.com
EST. 1956 LOCATION MAP
/1
/2
:2
:5
P M
C
U se rs \c a rs o n b ia n ch i\
D o cu m e n ts \1
G il e s
C o u n ty B o a rd R o o m v cb ia n ch iH
R N
C S
.r v t
G001
TI
TL
E
SH
EE
T
R
EL
O C
A
TI
O N
O F
G
IL
ES
C
O U
N
TY
A D
M
IN
IS
TR
A
TI
V E
B O
A R
D R
O O
M
19482
02/13/2026
PROJECT NO.: 19482
02/13/2026
ISSUED AS BRIDGING DOCUMENTS
CWB
MES
MES
RELOCATION OF GILES COUNTY
ADMINISTRATIVE BOARD ROOM
1 TAYLOR AVE, PEARISBURG, VA 24134
SHEET INDEX
SHEET NAME SHEET NUMBER
GENERAL
TITLE SHEET G001
LIFE SAFETY
LIFE SAFETY DATA & PROJECT INFORMATION LS100
LIFE SAFETY FLOOR PLAN LS101
ARCHITECTURAL
GENERAL NOTES, LEGENDS, ABBREVIATIONS & ARCHITECTURAL SPECIFICATIONS A001
DEMOLITION FLOOR PLAN AD101
NEW WORK FLOOR PLAN A101
REFLECTED CEILING PLAN A104
ENLARGED PLANS A401
BOARD ROOM CASEWORK A402
INTERIOR ELEVATIONS A403
DOOR SCHEDULE, NOTES, & LEGENDS A601
FINISH SCHEDULE, PARTITION TYPES, NOTES, & LEGENDS A701
MECHANICAL
FIRST FLOOR PLAN M100
ELECTRICAL
GENERAL NOTES, LEGENDS, & ABBREVIATIONS E001
LIGHTING PLAN E101
POWER PLAN E102
COMMUNICATION PLAN E103
DETAILS E501
ONE-LINE DIAGRAM E601
SCHEDULES E701
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
BRIDGING DOCUMENT
ROOM
R O
O M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M
ADMINISTRATIVE BOARD ROOMROOM ROOMROOM ROOMROOM
R O
O M
R O
O M
R O
O M
R
EL
O C
A
TI
O N
O F
G
IL
ES
C
O U
N
TY
A D
M
IN
IS
TR
A
TI
V E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O O
M
GILES COUNTY INDUSTRIAL
DEVELOPMENT AUTHORITY (GCIDA)
BUILDING AREA SUMMARY
CODE BUILDING AREA (RENOVATED AREA):
GROSS BUILDING AREA (RENOVATED AREA):
3,234 SF
3,076 SF
CODES & REGULATIONS
2021 VIRGINIA EXISTING BUILDING CODE, (VEBC)
2021 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF THE VIRGINIA UNIFORM
STATEWIDE BUILDING CODE (VUSBC)
2017 ICC/ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
2021 VIRGINIA MECHANICAL CODE
2021 VIRGINIA PLUMBING CODE
2020 NFPA 70 NATIONAL ELECTRICAL CODE
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (ADAAG)
FIRE-RESISTANCE RATING
REQUIREMENTS
BUILDING ELEMENT
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS (HOURS)
FIRE RATING
(EXCERPT FROM VCC TABLE 601, UON)
BEARING WALLS
EXTERIOR
INTERIOR
0 HR
0 HR
CONSTRUCTION TYPE: IIB
PRIMARY STRUCTURAL FRAME 0 HR
NONBEARING WALLS & PARTITIONS
EXTERIOR (VUSBC TABLE 602) 0 HR
NONBEARING WALLS & PARTITIONS
INTERIOR 0 HR
FLOOR CONSTRUCTION & SECONDARY MEMBERS 0 HR
ROOF CONSTRUCTION & SECONDARY MEMBERS 0 HR
BUILDING ELEMENT FIRE RATING
MISCELLANEOUS FIRE-RESISTANCE RATING REQUIREMENTS
CORRIDORS (VCC TABLE 1020.2) 0 HR
GENERAL INFORMATION
RENOVATIONS REQUIRED TO ACCOMMODATE THE RELOCATION OF GILES
COUNTY'S ADMINISTRATIVE BOARD ROOM
SCOPE:
CONSTRUCTION CLASSIFICATION:
CONSTRUCTION TYPE: IIB (PER ORIGINAL CONSTRUCTION DRAWINGS)
EXISTING BUILDING IS FULLY SPRINKLERED
OCCUPANCY:
DESCRIPTION: MIXED-USE, NON-SEPARATED
OCCUPANCY CLASSIFICATION: BUSINESS (B) & ASSEMBLY (A-3)
MAXIMUM TRAVEL DISTANCES:
EXIT ACCESS TRAVEL DISTANCE (VCC TABLE 1017.2):
DEAD ENDS (VCC 1020.5):
250 FT MAX
20 FT MAX
INTERIOR FINISH REQUIREMENTS:
CORRIDOR WALLS & CEILINGS (VCC TABLE 803.13):
-CLASS C
FLOORS (VCC 804.4.2):
-CLASS II
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
ROOM & ENCLOSED SPACE WALLS & CEILINGS (VCC TABLE 803.13):
-CLASS C
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
CRITICAL RADIANT FLUX NOT LESS THAN 0.22 WATTS/CM
ASBESTOS CONTAINING MATERIALS AND/OR PAINTS CONTAINING LEAD SHALL
NOT BE USED IN ANY FORM ON THE PROJECT.
EXIT ENCLOSURES & EXIT PASSAGEWAYS (VCC TABLE 803.13):
-CLASS B
FLAME SPREAD INDEX 26-75
SMOKE-DEVELOPED INDEX 0-450
ALTERATIONS ARE CLASSIFIED AS LEVEL 2
300 FT MAX
50 FT MAX
ASSEMBLY (A)
ASSEMBLY (A)
BUSINESS (B)
BUSINESS (B)
MEANS OF EGRESS
LEVEL 1 PROVIDED
NUMBER OF EXITS
REQUIRED
(VCC SECTION 1006.3.1)
EGRESS CAPACITY (.15"/OCC)
108.25"44"
(VCC 1005.3.2, EXCEPTION)
OCCUPANCY LOAD SUMMARY
TOTAL 161
FUNCTION OF SPACE
MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
SF/OCCUPANT
300 GROSS
ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT
ROOMS
(EXCERPT FROM VCC TABLE 1004.5)
ASSEMBLY WITHOUT FIXED SEATS
CONCENTRATED (CHAIRS ONLY-NOT FIXED)
STANDING SPACE
UNCONCENTRATED (TABLES & CHAIRS)
150 GROSS
7 NET
5 NET
15 NET
BUSINESS
LIBRARY
50 GROSSLOCKER ROOMS
200 GROSSPARKING GARAGES
200 GROSSRESIDENTIAL
50 NETREADING ROOMS
100 GROSSSTACK AREA
500 GROSSWAREHOUSES
40 NETCOURTROOMS-OTHER THAN FIXED SEATING AREAS
500 GROSSSTAGES & PLATFORMS
EDUCATIONAL (K-12)
CLASSROOM AREA
SHOPS & OTHER VOCATIONAL ROOM AREAS
20 NET
50 NET
50 GROSSEXERCISE ROOMS
200 GROSSKITCHENS (COMMERCIAL)
REFER TO LIFE SAFETY DRAWING FOR OCCUPANT LOAD BREAKDOWN
CALCULATED PER VUSBC TABLE 1004.5 OR ACTUAL NUMBER OF OCCUPANTS
SCHEDULED, WHICHEVER IS GREATER
FRONT APPROACH - PULL SIDE
0"
M
IN
MIN
18"
FRONT APPROACH - PUSH SIDE NEW BUILDINGS
*IF BOTH CLOSER AND LATCH ARE PROVIDED
2"
M
IN
12" MIN *
HINGE APPROACH - PULL SIDE
0"
M
IN
MIN
36"
HINGE APPROACH - PULL SIDE
4"
M
IN
MIN
42"
HINGE APPROACH - PUSH SIDE
2"
M
IN
MIN
22"
LATCH APPROACH - PULL SIDE
*54" MINIMUM IF CLOSER IS PROVIDED
8"
M
IN
MIN
24"
LATCH APPROACH - PUSH SIDE
*48" MINIMUM IF CLOSER IS PROVIDED
2"
M
IN
MIN
24"
FRONT APPROACH - PUSH SIDE EXISTING BUILDINGS
*IF BOTH CLOSER AND LATCH ARE PROVIDED
8"
M
IN
12" MIN *
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:5
P
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
LS100
LI
F
E S
A F
E T
Y D
A T
A
P R
O
JE
C T
I N
F O
R M
A T
IO
N
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
1/4" = 1'-0"
DOOR APPROACH 2017 ICC A117.1 404.2.3.2
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
BRIDGING DOCUMENT
3,234 SF
3,076 SF
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O O
M
GENERAL LIFE SAFETY NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EXIT LIGHTS, EMERGENCY LIGHTS, AND FIRE
ALARM SYSTEM.
2. MOUNT FIRE EXTINGUISHER CABINETS AND BRACKET-MOUNT EXTINGUISHERS WITH CENTERLINE OF
CABINET DOOR PULL OR EXTINGUISHER ACTUATOR AT 4'-0" AFF.
3. WHERE OCCUPANT LOAD OF SPACES IS INDICATED WITH WORK "ACTUAL", THE OCCUPANT LOAD OF
SUCH SPACE SHALL BE POSTED AT THE DIRECTION OF THE LOCAL BUILDING OFFICIAL.
102 113
127'-1"
36 SF
323 SF
470 SF
296 SF
1,189 SF
ACTUAL
65 SF
65 SF
39 SF
BM
(ABC)
RC
SRC
SMC
BM
RECESSED CABINET
SEMI-RECESSED CABINET
SURFACE MOUNTED
BRACKET MOUNTED
ABC
BC
WC
K
CO2
DRY CHEMICAL
DRY CHEMICAL
WET CHEMICAL
KITCHEN
CARBON DIOXIDE
FIRE EXTINGUISHER MOUNTING: FIRE EXTINGUISHER TYPE:
TYPE
MOUNTING
FIRE EXTINGUISHER LEGEND
EGRESS PATHDISTANCE
OCCUPANCY LOAD DESIGNATION
AREA (SF)
LIFE SAFETY LEGEND
BUSINESS (GROUP B) - GROSS AREA EXTENT
ASSEMBLY (GROUP A-3) - GROSS AREA EXTENT
EGRESS DOOR CAPACITY###
SCALE: 3/32" = 1'-0"
5'-4" 10'-8"0 21'-4"
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:1
A
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
LS101
LI
F
E S
A F
E T
Y F
LO
O
R P
LA
N
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
SCALE: 3/32" = 1'-0"LS101
1 LIFE SAFETY FLOOR PLAN KEY PLAN
SCALE: NTS
WORK AREA
BRIDGING DOCUMENT
R O
O M
R
EL
O C
A
TI
O N
O F
G
IL
ES
C
O U
N
TY
A D
M
IN
IS
TR
A
TI
V E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
A101A
CONSTRUCTION NOTE DESIGNATION
TOILET & BATH ACCESSORY DESIGNATION
A101
ROOM NAME
PARTITION TYPE DESIGNATION
NEW CONSTRUCTION
EXISTING CONSTRUCTION
EXISTING TO BE DEMOLISHED
DOOR/OPENING NUMBER DESIGNATION
ROOM NUMBER DESIGNATION
FLOOR LEVEL
SUFFIX AT MULTIPLE
DOOR/OPENING LOCATIONS
DOOR/OPENING NUMBER
BUILDING AREA
ROOM NUMBER
BUILDING AREA
FLOOR LEVEL
DEMOLITION NOTE DESIGNATION
E00 WINDOW TYPE DESIGNATION
(E=EXTERIOR / I=INTERIOR)
1 REVISION NUMBER DESIGNATION
A101A101
1 SIM
SECTION CUT DESIGNATION
(DETAIL DESIGNATION SIMILAR)
NUMBER INDICATES
SECTION OR DETAIL
SHEET NUMBER WHERE
SECTION OR DETAIL IS
DRAWN
SHEET NUMBER WHERE
SECTION OR DETAIL IS
TAKEN
ELEVATION DESIGNATION
SIM A101
A101
SIM1
A101
A101
NUMBER INDICATES ELEVATION
SHEET NUMBER WHERE
ELEVATION IS TAKEN
SHEET NUMBER WHERE
ELEVATION IS DRAWN
INTERIOR
ELEVATION
EXTERIOR
ELEVATION
MATCHLINE
0'-0"
SPOT ELEVATION
00 COLUMN LINE/HEAD
DATUM LINE
LEVEL
0'-0"
AREA 'A'
KEY PLAN AREA
ARCHITECTURAL LEGEND
XX-00
OPENING FRAME DESIGNATION
NUMBER
MATERIAL
AREA 'B'
A101, A102...
ADDITIONAL
SHEET
REFERENCES
ROOM SIGNAGE DESIGNATION
CONCRETE
MASONRY UNIT
CONCRETE
STONE VENEER
FACE BRICK
GYPSUM WALLBOARD
METAL/WOOD STUD
INSULATION - BATT
INSULATION - RIGID
STEEL
CAVITY DRAINAGE
MATERIAL
FINISH CARPENTRY
EARTH
GRAVEL
PLYWOOD
GROUT
INSULATION - SPRAY
ROUGH CARPENTRY
BLOCKING
ALUMINUM
MATERIAL LEGEND
GENERAL CONSTRUCTION NOTES:
1. ALL WORK SHALL BE PERFORMED IN OBSERVANCE OF LOCAL, STATE, AND FEDERAL CODES AND
REGULATIONS.
2. EXISTING CONDITIONS SHOWN HEREIN WERE TAKEN FROM SITE OBSERVATIONS AND COMPLETE
OR PARTIAL SETS OF ORIGINAL DESIGN DRAWINGS WHEN MADE AVAILABLE. ANY
DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL BUILT CONDITIONS ARE TO BE
REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
3. LOOSE FURNISHINGS, APPLIANCES, AND EQUIPMENT ARE NOT INCLUDED WITHIN THIS
PROJECT'S SCOPE (NIC), UNLESS OTHERWISE NOTED.
4. DO NOT "SCALE" DRAWINGS. USE DIMENSIONAL INFORMATION PROVIDED ONLY. FOR
DIMENSIONS NOT SHOWN OR IN QUESTION, CONTRACTOR SHALL REQUEST CLARIFICATION
FROM ARCHITECT PRIOR TO PROCEEDING.
5. ALL DIMENSIONS ARE MEASURED TO FACE OF METAL AND/OR WOOD STUDS OR MASONRY
CONSTRUCTION UNLESS OTHERWISE NOTED.
6. ALL DIMENSIONS NOTED AS "CLEAR," ARE FROM FACE OF FINISH TO FACE OF FINISH.
7. PROVIDE CONCEALED FIRE-RETARDANT TREATED WOOD BLOCKING AT LOCATIONS OF WALL-
MOUNTED EQUIPMENT, CASEWORK, SHELVING, AND TOILET ACCESSORIES.
8. ALL SIDEWALKS LOCATED ALONG ACCESSIBLE ROUTE SHALL HAVE A 5% MAXIMUM SLOPE
UNLESS OTHERWISE INDICATED AS A RAMP.
9. REFER TO ENLARGED FLOOR PLANS FOR PARTITION TYPES, DIMENSIONS, AND RELEVANT
CONSTRUCTION RELATED FEATURES AND EQUIPMENT IN THOSE AREAS.
10. ALL INTERIOR PARTITIONS ARE PARTITION TYPE 'A1' (UON).
11. ALL DOORS LOCATED IN STUD PARTITIONS ARE TO BE LOCATED 4" FROM AN ADJACENT WALL TO
THE BACK OF THE FRAME OR CENTERED BETWEEN 2 ADJACENT WALLS UNLESS OTHERWISE
NOTED.
12. ALL DOORS LOCATED IN MASONRY CONSTRUCTION ARE TO BE LOCATED 8" FROM AN ADJACENT
WALL OR CENTERED BETWEEN 2 ADJACENT WALLS UNLESS OTHERWISE NOTED.
13. PROVIDE MINIMUM 1'-6" CLEAR ON PULL SIDE OF DOORS BETWEEN JAMB AND INTERSECTING
WALL ON LATCH SIDE OF DOOR. PROVIDE 1'-0" CLEAR ON PUSH SIDE OF DOOR BETWEEN JAMB
AND INTERSECTING WALL ON LATCH SIDE OF DOOR FOR ALL DOORS WITH BOTH A LATCH AND A
CLOSER.
14. REFER TO ENLARGED FLOOR PLANS FOR PARTITION TYPES, DIMENSIONS, AND RELEVANT
CONSTRUCTION RELATED FEATURES AND EQUIPMENT IN THOSE AREAS.
15. PROVIDE SEALANT AT FULL PERIMETER OF ALL NEW OPENINGS AND PENETRATIONS AT EACH
SIDE, TYP.
16. REFER TO DRAWINGS LS100 FOR REQUIRED ACCESSIBLE CLEARANCES AT APPROACHES TO
DOORS FROM EACH SIDE.
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:5
P
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
A001
G E
N E
R A
L N
O T
E S
LE
G E
N D
S
A B
B R
E V
IA
T
IO
N
S
A R
C H
IT
E
C T
U R
A L
S P
E C
IF
IC
A T
IO
N
S
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
OCCURS WHERE ARE INDICATED ON DRAWINGS.#
GENERAL DEMOLITION NOTES:
1. ANY DISCREPANCIES BETWEEN ITEMS NOTED FOR DEMOLITION AND ACTUAL FIELD CONDITIONS
ARE TO BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF DEMOLITION.
2. DO NOT REMOVE OR DEMOLISH ANY LOAD-BEARING BUILDING ELEMENTS WITHOUT FIRST
CONTACTING THE ARCHITECT/STRUCTURAL ENGINEER.
3. REMOVE AND/OR CAP OFF ANY MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS
CONTAINED WITHIN CONSTRUCTION SCHEDULED TO BE REMOVED. CAP OFF BEHIND FACE OF
EXISTING WALLS INDICATED TO REMAIN OR BELOW THE FLOOR SLAB. COORDINATE THESE
REQUIREMENTS WITH MECHANICAL, PLUMBING, AND ELECTRICAL REQUIREMENTS.
4. LEGALLY DISPOSE OF ALL MATERIALS ASSOCIATED WITH SELECTIVE DEMOLITION WORK UNLESS
OTHERWISE NOTED TO BE PROVIDED TO OWNER OR SALVAGED FOR REUSE.
5. COORDINATE ANY REQUIRED TEMPORARY UTILITY OR SERVICE SHUT-OFF WITH OWNER AND
OTHER REQUIREMENTS FOUND IN THE CONTRACT DOCUMENTS.
6. REMOVE FROM WITHIN WORK AREA ALL EXISTING HVAC DUCTWORK AND EQUIPMENT AND
ELECTRICAL CONDUITS AND DEVICES UNLESS SPECIFICALLY STATED TO REMAIN PER THE
MECHANICAL AND ELECTRICAL DRAWINGS.
7. THE EXISTING FIRE PROTECTION SYSTEM TO REMAIN AND BE REDESIGNED TO SERVE THE NEW
FLOOR PLAN ARRANGEMENT.
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:5
P
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
AD101
D E
M O
LI
T
IO
N
F
LO
O R
P
LA
N
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
SPECIFIC DEMOLITION NOTES
1 REMOVE PORTION OF EXISTING EXTERIOR WALL AS REQUIRED TO ACCOMMODATE
NEW DOOR AND FRAME
2 REMOVE EXISTING PARTITION FRAMING COMPLETE
3 REMOVE EXISTING HVAC UNIT COMPLETE
4 SAW CUT EXISTING CONC SLAB AS REQUIRED TO ALLOW FOR INSTALLATION OF
NEW SANITARY PIPING AND ROUGH-IN. COORDINATE WITH PLUMBING DWGS.
5 REMOVE EXISTING HM DOOR AND FRAME COMPLETE
SCALE: 1/4" = 1'-0"
2' 4'0 8'
SCALE: 1/4" = 1'-0"AD101
1 DEMOLITION PLAN
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
KEY PLAN
SCALE: NTS
WORK AREA
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
OCCURS WHERE ARE INDICATED ON DRAWINGS.#
EXECUTIVE CONFERENCE
STORAGE
BOS MTG ROOM
IT ROOM
STOR
CONFERENCE/STORAGE
CONFERENCE
STORAGE
W. TLT
M. TLT
COFFEE
COFFEE
UP +6"
UP +6"
A403
A101
REF
CORRIDOR
CORRIDOR
VEST
103 101A
102 113
101B
104C104B
104A
A101 A402
A101 A401
A403
A101
A403
A101
7'-6" +/- 5'-3 1/2" +/- 9'-0" 5'-3 1/2" +/- 23'-3" +/-
CLEAR
7'-0"
5'-0"
1/
8"
2' -0
/8
2'
-1
/4
21'-10" +/-5'-0"
0"
4'
-3
/8
7/
8"
RAMP
CONNECT NEW TO OLD SANITARY
ALIGN PARTITION FRAMING
W/ EXISTING COLUMN FACE
ALIGN
2 2 2 2
NOTES:
1. EPOXY GROUT DOWELS INTO EXISTING S.O.G. W/ HILTI HIT-RE 500
V3 ADHESIVE ANCHORING SYSTEM,
2. COMPACT FILL AND STONE UNDER EXISTING S.O.G. WHERE
EXISTING STONE AND SUBGRADE SLUFF FROM UNDER EXISTING
SLAB. CONTROLLED LOW-STRENGTH MATERIAL MAY BE USED AT
CONTRACTOR'S OPTION IN LIEU OF COMPACTED FILL AND STONE.
3. REPAIR OR REPLACE VAPOR BARRIER WHERE OCCURS.
TO INSTALL UTILITIES
MIN. WITH REQ'D4 1/2" TYP
NEW S.O.G THICKNESS AND
ELEVATION TO MATCH EXIST. S.O.G.
#3@12" DOWELS, SEE NOTE 1
NEW 6" VDOT #21 STONE
COMPACTED. SEE NOTE 2
UTILITY
SAW CUT EXIST. S.O.G. 1 1/2" DEEP ON
EACH SIDE OF SLAB TO BE DEMOLISHED
EXIST. S.O.G.
EXIST. POROUS FILL
EXIST. SUBGRADE
SCALE: 1/4" = 1'-0"
2' 4'0 8'
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:5
P
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
A101
N E
W W
O R
K F
LO
O
R P
LA
N
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026CONSTRUCTION NOTES
1 PROVIDE NEW 4" CONC FLOOR INFILL WHERE EXISTING CONCRETE FLOOR SLAB WAS
REMOVED FOR INSTALLATION OF NEW SANITARY WASTE PIPING. REFER TO DETAIL THIS
DRAWING.
2 RETAIN EXISTING METAL WALL STUD FRAMING LOCATED ALONG PERIMETER EXTERIOR
WALLS OF WORK AREA. ADD FOIL FACED BATT INSULATION (R-19) AND REPAIR FRAMING AS
REQUIRED. FINISH WALL WITH 5/8" GWB AND PROVIDE A LEVEL 4 FINISH.
3 PROVIDE AN ACCESSIBLE RAMP LEADING FROM DOOR NO. 104A TO THE NEAREST EXISTING
SIDEWALK. THE RAMP SHALL MEET ALL REQUIREMENTS OF THE ADA AND AS LISTED BELOW.
SCALE: 1/4" = 1'-0"A101
1 NEW WORK PLAN
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
a. MAXIMUM SLOPE SHALL BE 1 UNIT VERTICAL FOR EACH 12 UNITS HORIZONTAL.
b. MAXIMUM SINGLE RAMP RUN SHALL BE 30'-0" WITH A MAXIMUM RISE OF 30". EACH
RAMP RUN SHALL BE SEPARATED BY A LANDING.
c. PROVIDE A 5'-0" BY 5'-0" LANDING AT BOTH THE TOP AND BOTTOM OF THE RAMP.
PROVIDE REQUIRED CLEARANCES AT THE TOP LANDING WHERE ADJACENT TO A
DOOR.
d. MINIMUM CLEAR WIDTH OF RAMP BETWEEN HANDRAILS SHALL BE 36".
e. LANDING LENGTHS PARALLEL TO RAMP RUN SHALL BE 60" IN LENGTH.
f. RAMP EDGE PROTECTION SHALL BE PROVIDED BY EITHER EXTENDED FLOOR OR
GROUND SURFACE OR BY CURB OR BARRIER EDGE PROTECTION. TYPICAL DETAIL - S.O.G REPAIR KEY PLAN
SCALE: NTS
WORK AREA
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
REFLECTED CEILING LEGEND:
LAY-IN LIGHT
SURFACED MOUNTED LIGHT
PENDANT LIGHT (UON)
GYPSUM CEILING
24"x24" SUSPENDED ACOUSTICAL PANEL CEILING
PENDANT LIGHT (UON)
CAN LIGHT
AIR DEVICES-SUPPLY
AIR DEVICES-RETURN
AIR DEVICES-EXHAUST
SPRINKLER HEAD
EXIT SIGN
EQ EQ EQ EQ
EQ
EQ
EQ
EQ
SPRINKLER HEAD OR OTHER
CEILING MOUNTED DEVICE
RECESSED CAN LIGHT
OCCURS WHERE ARE INDICATED ON DRAWINGS.C#
SCALE: 1/4" = 1'-0"
2' 4'0 8'3/4" = 1'-0"
TYP CEILING MOUNTED FIXTURE LOCATION
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:3
A M
C
U se rs \c a rs o n b ia n ch i\
D o cu m e n ts \1
G il e s
C o u n ty B o a rd R o o m v cb ia n ch iH
R N
C S
.r v t
A104
R E
F
LE
C T
E D
C E
IL
IN
G P
LA
N
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
CEILING NOTES
SCALE: 1/4" = 1'-0"A104
1 REFLECTED CEILING PLAN
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
KEY PLAN
SCALE: NTS
WORK AREA
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
15" MIN
6"
M A
X
8"
3"
DRINKING
FOUNTAIN
7"
M A
X
16" - 18"
4"
M A
X
7"
9"
FLUSH VALVE
LEVER AT OPEN
SIDE OF STALL
FACE OF SIDE
WALL
FLUSH VALVE LEVER AT
OPEN SIDE OF STALL
FACE OF SIDE
WALL
LAVATORY
WATER CLOSET URINAL
1'-3" MIN
15" MIN
TO
R
IM
4"
M A
X
0"
M A
X
8"
M A
X 5
0"
8"
M A
X
C A
B
IN
ET
S
B
EL
O W
W A
LL
8"
M A
X
4"
4"
5"
8"
MIRROR SOAP DISPENSER TRASH
RECEPTACLE
MOP/BROOM
HOLDER
COAT/ROBE
HOOK
DIAPER
CHANGING
STATION
SHOWER CURTAIN
ROD
PAPER TOWEL
DISPENSER
8"
M A
X
SEMI-RECESSED
HAND DRYER
8"
4"
CHANGING TABLE
SURFACE IN FOLD-OUT
POSITION
REFLECTIVE
SURFACE
2'-7"
3 3/4" MAX
SANITARY NAPKIN
DISPOSAL
SHOWER
ELEVATION
CONTROL WALL
36" MIN 5 3/4"
9"
1"42" MIN
1'-0 1/4" MAX
39" - 41"
8"
M
IN
FACE OF
REAR WALL
FACE OF
SIDE WALL
1'-4"
1"
GRAB BARS
3"
6"
24" MIN 12" MIN
3"
6"
8"
7"
7" - 9"
TOILET TISSUE
DISPENSER
5"
M
IN
8"
M A
X
1'-5"
M
IN
6"
3"
6"
SHOWER
ELEVATION
SIDE WALL
9"
1"
SHOWER CONTROL
AND HANDSHOWER
LOCATION
16" MIN
27" MAX
8"
M
IN
8"
M A
X
7"
9"
GENERAL NOTES:
1. TOILET ACCESSORY ITEMS ARE INDICATED ON DRAWINGS BY
2. REFER TO CASEWORK ELEVATIONS ON SHEET A403 FOR ADDITIONAL TOILET
ACCESSORIES REQUIRED AS PART OF WORK.
3. GRAB BARS AND ACCESSORIES SHALL BE MOUNTED IN ACCORDANCE WITH
2017 ICC/ANSI A117.1.
4. REFER TO SPEC SECTION 102800 - "TOILET, BATH, AND LAUNDRY
ACCESSORIES" ON DRAWING A001 FOR ACCESSORY TECHNICAL
REQUIREMENTS AND DESCRIPTION.
5. PROVIDE UNDER LAVATORY PROTECTIVE PIPE COVER AT EACH WALL HUNG
LAVATORY.
6. ACTUAL DIMENSIONS MAY VARY WITH APPROVED MANUFACTURER.
COORDINATE ALL REVISIONS AS REQUIRED.
OCCURS WHERE ARE INDICATED ON DRAWINGS.00
W. TLT
M. TLT
040301 09
040301
A2
A1
A1
CHASE
3/
4"
6"
6"
8'-0"
7'
-1
/4
A1
A2
A1
A2
SCALE: 1/4" = 1'-0"
2' 4'0 8'
1/4" = 1'-0"
PLUMBING FIXTURES MOUNTING SCHEDULE
1/4" = 1'-0"
TOILET ACCESSORIES MOUNTING SCHEDULE
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:5
P
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
A401
E N
LA
R
G E
D P
LA
N
S
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
TOILET ACCESSORY LEGEND
DESCRIPTION NUMBER PROVIDED/INSTALLED
42" HORIZONTAL GRAB BAR 01
32" HORIZONTAL GRAB BAR 02
18" VERTICAL GRAB BAR 03
TOILET TISSUE DISPENSER 04
SOAP DISPENSER 05
18" x 36" FRAMED MIRROR UNIT 07
SANITARY NAPKIN DISPOSAL UNIT 09
PAPER TOWEL DISPENSER 11
COAT HOOK 12
SCALE: 1/2" = 1'-0"A101 A401
1 ENLARGED PLAN
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
SCALE: 1/2" = 1'-0"
1' 2'0 4'
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
A402
A402
UP +6"
104B
'A'
'A'
C
LE
A R
6"
C
LE
A R
6"RAMP UP
+6"
2'-6"
6'-0"4'-0"
5'
-4
/8
C
LE
A R
6"
TOW +3'-6"
TOW +3'-6"
METAL SUPPORT
BRACE, TYP. OF 4
CABLE GROMMETS, TYP OF 5
5'-0" 2'-0"
5"
SPEAKER'S PODIUM
(PORTABLE)
A402A402
A402
A402
A402
A402
A402
A402
C L
O F
D A
IS
DIAS FLOOR
0'-6"6"
EXISTING FLOOR LEVEL
5"3'-6"
24'-4" +/-
GWB
WOOD TRIM ON 5/8" GWB PANEL, TYP.
TOE SPACE
16'-6" +/- 5"
FIN FLOOR
0'-0"
6"
0"
2'-5"
WOOD TRIM ON
3/4" FINISH
PLYWOOD, TYP.
SLOPED TOP W/
PENCIL STOP
ADJUSTABLE SHELF
FIN FLOOR
0'-0"
0"
2'-0"
6"
4"
WOOD TRIM ON
3/4" FINISH
PLYWOOD, TYP.
TOE SPACE AT
FRONT ONLY
SLOPED TOP W/
PENCIL STOP
FIN FLOOR
0'-0"
4"
2'-5"
TOE SPACE AT
FRONT ONLY
WOOD TRIM ON
3/4" FINISH
PLYWOOD, TYP.
4"
6"
6"
3'-0"
6"
6"
2'-7"5"
EXISTING CONCRETE FLOOR SLAB
6" 2X6 BAND BOARD
2X4 SILL
2X6 WOOD FRAMING AT 1'-4" OC
1/2" PLYWOOD SUBFLOOR
QR 75
ELECTRICAL STUB-OUTS, SEE ELECTRICAL
SHEETS FOR EXACT LOCATIONS
2X4 BLOCKING
EDGEBANDED CABINET GRADE FIN.
METAL SUPPORT BRACE AT 3'-0" OC
AS INDICATED
ELECTRICAL
RACEWAY
2X6 FRAMING AT 1'-4" OC
SCOTIA 75
SOLID SURFACE COUNTERTOP
WOOD NOSING, TYP.
MISC. FIN TRIM
N12
SOLID SURFACE INLAY
2X4 TOP PLATE
N12
SCOTIA 75
S4S STOCK
BC 125 AT
PERIMETER
2X NAILER AS
REQUIRED
WD 2X6 PROFILE
AS REQUIRED
5/8" GWB PANEL
S4S STOCK
TOE BOARD
QR 75 WOOD TRIM PROFILE NUMBERS REFERENCE THE "WOOD MOULDING CATALOG - STANDARD PROFILES"
AS PUBLISHED BY
TILO INDUSTRIES, 2738 BUFFALO ROAD, LEWISBURG, PA 17837
TELEPHONE: 570.524.9990, FAX: 570.524.9991, EMAIL: SALES@TILOINDUSTRIES.COM
ALL WOOD TRIM PROFILES SHALL BE PAINT GRADE POPLAR
BC 125 SCOTIA 75
QR 75
N 12
S4 S
ST
O
C K
/4
X
/2
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:1
:1
A
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
A402
B O
A R
D R
O O
M C
A S
E W
O R
K
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
SCALE: 1/2" = 1'-0"A101 A402
1 ENLARGED PLAN
SCALE: 1/2" = 1'-0"A402 A402
3 CASEWORK ELEVATION
SCALE: 1/2" = 1'-0"A402 A402
4 CASEWORK ELEVATION
SCALE: 1/2" = 1'-0"A402 A402
5 CASEWORK ELEVATION
SCALE: 1/2" = 1'-0"A402 A402
6 CASEWORK ELEVATION
SCALE: 3" = 1'-0"A402 A402
2 CASEWORK SECTION WOOD TRIM PROFILES
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
3'-0" 2'-6" 2'-6" 3'-0" 3'-0"
17'-0"
0"
6"
3'-0"
5 TYP
A403A403
4"
0"
4"
PLAS LAM WALL CABINETS
PLAS LAM WALL CABINETS
PLAS LAM BASE CABINETS
RUBBER BASE
SOLID SURFACE COUNTERTOP
4" BACKSPLASH
3'-6" 3'-6"
7'-0"
3'-6" 3'-6"
7'-0"
0"
4"
6"
0"
4"
PLAS LAM WALL CABINET
ADJUSTABLE SHELVES
4" BACKSPLASH
SOLID SURFACE COUNTERTOP
PLAS LAM BASE CABINET
RUBBER BASE
6"
FILLER 3'-0" 3'-0" FILLER
0"
4"
6"
0"
3'-0" 3'-0" FILLERFILLER
6'-4"
6'-4"
4"
PLAS LAM WALL CABINET
ADJUSTABLE SHELVES
4" BACKSPLASH
SOLID SURFACE COUNTERTOP
PLAS LAM BASE CABINET
RUBBER BASE
6"
4"x3/4" BACKSPLASH
SOLID SURFACE
COUNTERTOP
3/4" MDF, TYP EACH
SIDE OF BRACKET
3/4" MDF PANEL SUPPORT
BRACKETS CENTERED BETWEEN
SINKS AT 2'-6" ON CENTER MAX
20"H REMOVABLE ACCESS PANEL
CENTERED BELOW EACH SINK.
SECURE WITH 4 NO 10 WAFER-
HEAD FASTENERS, 1 IN EACH
CORNER OF PANEL
9"
A D
A R
EQ
M
IN
3"
7"
0"
2'-1"
ADA REQ MIN
8"
6"
4"x3/4" BACKSPLASH
PLASTIC LAMINATE
COUNTERTOP
WIRE PULL HANDLES
DRAWER ON SLIDES
PLASTIC LAMINATE CLAD BASE
CABINET WHERE INDICATED
ON ENLARGED PLANS
ADJUSTABLE SHELVES AND
RECESSED STANDARDS
1'-0"
T
YP
U
O N
6"
6"
4"WALL BASE
BLOCKING AT
1'-4" ON CENTER
2'-0"
1'-10" 0'-2"
PLASTIC LAMINATE CLAD WALL
CABINET WHERE INDICATED ON
ENLARGED PLANS
ADJUSTABLE SHELVES AND
RECESSED STANDARDS
TY
P
U
O N
8"
0"
2'-1"
SIDE SPLASH AT WALL
RETURN
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:5
P
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
A403
IN
T
E R
IO
R
E
LE
V A
T
IO
N S
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
SCALE: 1/2" = 1'-0"A101 A403
1 CASEWORK ELEVATION
SCALE: 1/2" = 1'-0"A101 A403
2 CASEWORK ELEVATION
SCALE: 1/2" = 1'-0"A101 A403
3 CASEWORK ELEVATION
SCALE: 1 1/2" = 1'-0"A403 A403
5 TYP ACCESSIBLE COUNTERTOP SECTION
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
SCALE: 1 1/2" = 1'-0"A403
4 TYPICAL CABINET SECTION
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
GENERAL DOOR NOTES:
1. PROVIDE CONTINUOUS BEAD OF SEALANT AT PERIMETER OF EACH SIDE OF OPENING
FRAME.
2. PROVIDE DOORS WITH A 3/4" UNDERCUT (UON).
3. INSTALL GLAZED OPENINGS WITH REMOVABLE GLAZING STOP ON SIDE OPPOSITE
PUBLIC OCCUPIED AREAS UNLESS OTHERWISE INDICATED.
4. SERVICE AND LUBRICATE ALL EXISTING DOOR HARDWARE.
5. KEY EACH NEW DOOR LOCK PER OWNER'S INSTRUCTION AND TIE TO BUILDING'S
EXISTING MASTER KEY SYSTEM.
6. ALL FINISH DOOR HARDWARE TO BE DESIGNED BY AN ARCHITECTURAL HARDWARE
CONSULTANT (AHC). PROVIDE ALL HARDWARE COMPONENTS REQUIRED FOR
COMPLETE OPENING FUNCTION AND PERFORMANCE.
DOOR SCHEDULE LEGEND
HM HOLLOW METAL
GHM GALVANIZED HOLLOW METAL
IG-1 1" INSULATED LOW-E GLASS
G-1 1/4" TEMPERED FLOAT GLASS
WD WOOD
DOOR SCHEDULE REMARKS:
REFER TO DOOR SCHEDULE FOR REMARK LOCATIONS.
1. FIELD MODIFY EACH LEAF OF EXISTING PAIR OF DOORS TO RECEIVE A NEW
NARROW LITE VISION KIT.
2. PROVIDE NEW WEATHERSTRIPPING AT FULL HEAD AND JAMB PERIMETER
WITH NEW DOOR SWEEP AND ADA THRESHOLD.
3. PROVIDE INSULATED GALVANIZED HOLLOW METAL DOOR AND FRAME.
PER SCHED
F
P
ER
S C
H
ED
U
LE
G N
NOTE: REFER TO DOOR SCHEDULE FOR DOOR MATERIAL REQUIREMENTS.
PER SCHED
P
ER
S C
H
ED
U
LE
PER SCHED
P
ER
S C
H
ED
U
LE
7"
7"
100 SQ IN MAX
FG
PER SCHED
P
ER
S C
H
ED
U
LE
/2
/2
/8
2"
SE
E
SC
H
ED
U
LE
SEE FRAME TYPE 5/8"
/2
/2
/8
2"
SE
E
SC
H
ED
U
LE
SEE FRAME TYPE 5/8"
3/8"
P
ER
S C
H
ED
U
LE
2" 2"
PER
SCHED 2"
P
ER
S C
H
ED
U
LE
4"
2"
PER
SCHED 2"
1 2
P
ER
S C
H
ED
U
LE
PER SCHEDULE
REFER TO PLAN
FOR PARTITION TYPE
SEALANT JOINT AT
PERIMETER EACH SIDE
METAL STUD BOX HEADER
HM FRAME
H1
PROVIDE MINIMUM
3 JAMB ANCHORS
EACH SIDE
SEALANT JOINT AT
PERIMETER EACH SIDE
STUDS AT JAMBS EACH
SIDE. EXTEND FULL HEIGHT
OF STRUCTURE
J1
P A
R
TI
TI
O
N T
YP
E
R
EF
ER
T
O P
LA
N
F O
R
HM FRAME
H2
J2
EXISTING EXT. WALL
10" +/-
ALUM. THRES. SET IN
FULL BED OF SEALANT
HM DOOR FRAME
MIN. 3 JAMB
ANCHORS EA SIDE
NEW DBL STUDS AT JAMBS
EXTEND FULL HGT OF STRUCT.
NEW 5/8" GWB
NEW BATT INSUL (R-19)
EXIST. METAL STUD FRAMING
EXISTING FACE BRICK
SEALANT JOINT AT
PERIMETER EA. SIDE
EXISTING EXT. WALL
10" +/-
EXISTING FACE BRICK
NEW WALL FLASHING
NEW 4"X4" LOOSE STL
LINTEL WITH MIN. 8"
BEARING EACH SIDE
SEALANT JOINT AT
PERIMETER EA. SIDE
EXIST. METAL STUD
FRAMING
NEW BATT INSUL (R-19)
NEW 5/8" GWB
NEW METAL STUD
BOX HEADER
HM DOOR FRAME
DOOR SCHEDULE
MARK
OPENING SIZE DOOR FRAME DETAILS
REMARKS
NO OF
LEAFS WIDTH HEIGHT MATERIAL THICKNESS TYPE
RATING
(MIN) LOUVER GLAZING HDW SET NO TYPE MATERIAL DEPTH PROFILE HEAD JAMB
101A 2 6'-0" 7'-0" EXIST 1 3/4" F - - G-1 EXIST - EXIST EXIST EXIST EXIST EXIST 1
101B 2 6'-0" 7'-0" WD 1 3/4" F - - G-1 PR EXIT DEV - HM 6" 1 H1 J1
102 1 3'-0" 7'-0" WD 1 3/4" F - - - STOREROOM - HM 6" 1 H1 J1
103 1 3'-0" 7'-0" EXIST 1 3/4" F - - - EXIST - EXIST EXIST EXIST EXIST EXIST
104A 1 3'-0" 7'-0" GHM 1 3/4" N - - IG-1 RIM EXIT DEV 2 GHM 8" 2 H2 J2 3
104B 1 3'-0" 7'-0" WD 1 3/4" F - - - OFFICE - HM 6" 1 H1 J1
104C 1 3'-0" 7'-0" WD 1 3/4" F - - - OFFICE - HM 6" 1 H1 J1
105 1 3'-0" 7'-0" WD 1 3/4" N - - G-1 RIM EXIT DEV - HM 6" 1 H1 J1
107 1 3'-0" 7'-0" WD 1 3/4" F - - - PRIVACY - HM 6" 1 H1 J1
108 1 3'-0" 7'-0" WD 1 3/4" F - - - PRIVACY - HM 6" 1 H1 J1
109 1 3'-0" 7'-0" WD 1 3/4" N - - G-1 OFFICE - HM 6" 1 H1 J1
110 1 3'-0" 7'-0" WD 1 3/4" F - - - STOREROOM - HM 6" 1 H1 J1
111 1 3'-0" 7'-0" GHM 1 3/4" N - - IG-1 RIM EXIT DEV - GHM 8" 2 H2 J2 2
112 1 3'-0" 7'-0" WD 1 3/4" N - - G-1 OFFICE - HM 6" 1 H1 J1
113 1 3'-0" 7'-0" WD 1 3/4" F - - - STOREROOM - HM 6" 1 H1 J1
SCALE: 1/4" = 1'-0"
2' 4'0 8'
1/4" = 1'-0"
DOOR TYPES
3" = 1'-0"
FRAME PROFILES
1/4" = 1'-0"
FRAME TYPES
SCALE: 3" = 1'-0"
2" 4"0 8"
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:5
P
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
A601
D O
O R
S C
H E
D U
LE
N O
T E
S
L
E G
E N
D S
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
1 1/2" = 1'-0"
DOOR HEAD AND JAMB CONDITIONS
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
SCALE: 1 1/2" = 1'-0"
4" 8"0 1'-4"
EXIST EXIST EXIST
EXIST EXIST EXIST EXIST
EXIST
SCALE: 3" = 1'-0"
2" 4"0 8"
SCALE: 1 1/2" = 1'-0"
4" 8"0 1'-4"
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
GENERAL FINISH NOTES:
1. TRANSITION BETWEEN DIFFERENT FLOOR FINISH MATERIALS OR COLORS SHALL BE
PROVIDED UNDER CENTERLINE OF DOORS UNLESS OTHERWISE NOTED.
2. PAINT ALL HOLLOW METAL DOORS AND FRAMES, STEEL PIPE
HANDRAILS/GUARDRAILS, AND ALL OTHER MISCELLANEOUS FERROUS METALS.
3. PROVIDE MOISTURE- AND MOLD-RESISTANT GWB AT ALL LAVATORY, SINK, TOILET,
AND WET AREAS.
FINISH SCHEDULE LEGEND
EXP EXPOSED CONSTRUCTION
PNT PAINTED FINISH (REFER TO PARTITION TYPES FOR SUBSTRATE)
ACT ACOUSTIC CEILING TILE
S CONC SEALED CONCRETE
LV LUXURY VINYL PLANK AND/OR TILE
RUBBER 4-INCH RUBBER WALLBASE
CPT CARPET
GENERAL PARTITION NOTES:
1. ALL INTERIOR PARTITIONS ARE PARTITION TYPE 'A1' (UON).
2. EXTEND GWB AND FURRING (WHERE APPLICABLE) TO UNDERSIDE OF DECK IN
SPACES NOT SCHEDULED TO RECEIVE FINISH CEILING. OTHERWISE,
TERMINATE GWB 6-INCH ABOVE FINISHED CEILING HEIGHT.
3. ALL STUDS AND FURRING USED FOR NON-STRUCTURAL INTERIOR PARTITIONS
ARE TO BE 25 GA (UON).
4. ALL METAL STUDS AT DOOR JAMBS AND BEHIND WALL-MOUNTED SINKS ARE
TO BE 20 GA.
5. PROVIDE 5/8-INCH MOISTURE- AND MOLD-RESISTANT GWB IN LIEU OF
STANDARD GWB AT JANITOR'S CLOSETS, LAVATORY SPACES, TLT/SHOWER
SPACES, LOCKER ROOMS AND OTHER WET WALLS.
NON-RATED PARTITION
A
TYPE
A1
STUD
SIZE
3 5/8"
PART
THICK
4 7/8"
SOUND ATTN
BLANKET
3"
6" M
IN
P
ER
F
IN
IS
H S
C H
ED
U
LE
FIN FLR
UNDERSIDE OF
DECK/STRUCTURE
DEFLECTION TRACK
CEILING, REFER TO
FINISH SCHEDULE
SOUND ATTENUATION
BLANKET (SEE SCHEDULE
BELOW)
1-LAYER OF 5/8" GWB
EACH SIDE
ACOUSTICAL SEALANT
METAL STUD AT 16" ON CENTER
(SEE SCHEDULE BELOW)
A2 3 5/8" 4 1/4" 3" (NOTE 1)
NOTE 1: OMIT GWB ON CHASE (CONCEALED) SIDE.
FINISH SCHEDULE
ROOM NO ROOM NAME FLOOR BASE
WALLS CEILING
REMARKSNORTH EAST SOUTH WEST MATERIAL HEIGHT
101 VEST CPT RUBBER PNT PNT PNT PNT ACT 8'-0"
102 IT ROOM LVT RUBBER PNT PNT PNT PNT EXP (PAINTED) 10'-0"
103 STORAGE LVT RUBBER PNT PNT PNT PNT EXP 10'-0"
104 EXECUTIVE CONFERENCE CPT RUBBER PNT PNT PNT PNT ACT 8'-0"
105 BOS MTG ROOM CPT RUBBER PNT PNT PNT PNT EXP (PAINTED) 10'-0"
106 CORRIDOR LVT RUBBER PNT PNT PNT PNT ACT 8'-0"
107 M. TLT LVT RUBBER PNT PNT PNT PNT ACT 8'-0"
108 W. TLT LVT RUBBER PNT PNT PNT PNT ACT 8'-0"
109 CONFERENCE LVT RUBBER PNT PNT PNT PNT ACT 8'-0"
110 STORAGE LVT RUBBER PNT PNT PNT PNT EXP (PAINTED) 10'-0"
111 CORRIDOR LVT RUBBER PNT PNT PNT PNT ACT 8'-0"
112 CONFERENCE/STORAGE LVT RUBBER PNT PNT PNT PNT ACT 8'-0"
113 STOR LVT RUBBER PNT PNT PNT PNT EXP (PAINTED) 10'-0"
1 1/2" = 1'-0"
PARTITION TYPES
SCALE: 1 1/2" = 1'-0"
4" 8"0 1'-4"
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:2
:5
P
M C
U se rs
\c a rs o n b ia n ch i\ D o cu m e n ts
\1
G il e s C o u n ty
B o a rd
R o o m v cb ia n ch iH R
N C
S .r v t
A701
F
IN
IS
H
S C
H E
D U
LE
P A
R T
IT
IO
N T
Y P
E S
N
O T
E S
LE
G
E N
D S
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
CWB
MES
MES
19482
02/13/2026
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
9'-9" +/-
9'-9" +/-
9'-9" +/-
9'-9" +/-
EXP (PAINTED) 10'-0"9'-9" +/-
BRIDGING DOCUMENT
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
EXECUTIVE
CONFERENCE
STORAGE
BOS MTG ROOM
IT ROOM
STOR
CONFERENCE/STORAGE
CONFERENCE
STORAGE
W. TLT
M. TLT
CEILING EXHAUST FAN EQUAL
TO GREENHECK SP-A90, 70
CFM WITH VIBRATION
ISOLATORS, BACKDRAFT
DAMPER, SPEED CONTROL,
6" DUCT UP TO ROOF CAP,
CONTROLLED BY LIGHT
SWITCH
T C
CARBON DIOXIDE SENSOR FOR
DEMAND CONTROL VENTILATION
1-TON DUCTLESS SPLIT
SYSTEM OVER DOOR
T
12.5 TON GROUND MOUNTED PACKAGED UNIT, 1305 CFM OUTSIDE AIR
(HOT-WATER, CHILLED WATER) WITH DEMAND CONTROL VENTILATION,
ECONOMIZER, POWER EXHAUST, SMOKE DETECTOR IN RETURN DUCT ON
4" HIGH ROOF CURB
RANGE HOOD WITH STAINLESS STEEL FINISH, EQUAL TO
BROAN-NUTONE MODEL BCSQ-130SS DUCTED TO THE EXTERIOR
CONNECT TO EXISTING
HOT WATER AND CHILLED
WATER DISTRIBUTION SYSTEM
VAV BOX WITH HOT
WATER REHEAT, TYP
VAV-
VAV-
2A
VAV-
2A
VAV-
VAV-
FLOOR CLEANOUT
FLOOR CLEANOUT
TRENCH AND BACKFILL FOR NEW SEWER LINE
CONNECT TO EXISTING SEWER LINE
ROUTE NEW HOT AND COLD WATER LINES TO
EXISTING HOT AND COLD WATER LINES IN
WATER SERVICE ENTRANCE ROOM
ADA WALL HUNG LAVATORY AND HARDWIRED SENSOR
FAUCET WITH TRAP WRAP AND SUPPLY WRAPS
ADA WALL HUNG LAVATORY AND HARDWIRED SENSOR
FAUCET WITH TRAP WRAP AND SUPPLY WRAPS
ADA FLOOR MOUNTED FLUSH VALVE WATER CLOSET
WITH ELONGATED OPEN FRONT SEAT, HARDWIRED
SENSOR OPERATED FLUSH VALVE WITH OVERRIDE BUTTON
4"
ADA FLOOR MOUNTED FLUSH VALVE WATER CLOSET
WITH ELONGATED OPEN FRONT SEAT, HARDWIRED
SENSOR OPERATED FLUSH VALVE WITH OVERRIDE BUTTON
ADA STAINLESS STEEL
UNDERMOUNT SINK WITH
FAUCET WITH WRIST BLADE
HANDLES
1/2"
1/2"
1-1/4"
2"
2"
1/2"
1"
1"
4"
1-1/4"
3/4"
1-1/4"
RAISE EXISTING P-TRAP
AND SEWER PIPING
FROM SECOND FLOOR
AS HIGH AS POSSIBLE
3" VTR
1/2" 1/2"
1-1/2"
1-1/4"
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
M100
F
IR
S T
F
LO
O R
P
LA
N
P R
O
JE
C T
N A
M E
P R
O
JE
C T
L O
C A
T
IO
N
SGT
SGT
SGT
19482
01/30/2026
SCALE: 1/8" = 1'-0"
4' 8'0 16'
1/8" = 1'-0"
HVAC PLAN - FIRST FLOOR - NEW WORK
NOTES:
1. DEMO EXISTING UNIT HEATER AND HYDRONIC PIPING IN THIS AREA.
2. EXISTING PACKAGED UNIT SIZE IS BASED ON SQUARE FOOTAGE. DURING DESIGN,
ACTUAL UNIT SIZE WILL BE DETERMINED BASED ON HVAC LOAD CALCULATIONS.
3. PACKAGED UNIT AND VAV BOXES SHALL HAVE BACNET CARDS FOR CONNECTION TO
EXISTING ALLERTON CONTROLS BAS SYSTEM.
NOTES:
1. DEMO EXISTING SPRINKLER HEADS IN THIS AREA.
2. PROVIDE NEW SPRINKLER HEAD LAYOUT PER NFPA 13; ORDINARY HAZARD GROUP 1 IN
BREAKROOM AND LIGHT HAZARD ELSEWHERE
1/8" = 1'-0"
PLUMBING PLAN - FIRST FLOOR - NEW WORK
MECHANICAL SPECIFICATIONS
A. PERMIT FOR ALL MECHANICAL WORK SHALL BE OBTAINED BY A
CONTRACTOR LICENSED IN WYTHEVILLE, VIRGINIA. ALL WORK SHAL BE
PERFORMED BY THIS CONTRACTOR.
B. COORDINATE WITH OTHER TRADES IN ORDER TO INSTALL ALL SYSTEMS
IN THE BEST ARRANGEMENT.
C. ALL EQUIPMENT SHALL BE FURNISHED, INSTALLED AND ADJUSTED
COMPLETE AND READY FOR USE.
A. ALL MECHANICAL EQUIPMENT SHALL BE IDENTIFIED WITH BLACK
BAKE-LITE TAGS WITH 3/4" HIGH WHITE LETTERS.
B. ALL GAS PIPING SHALL BE PAINTED YELLOW AND TAGGED WITH LABELS
AT 10 FT. INTERVALS AS MANUFACTURED BY SETON.
A. ALL PIPING SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO
THE BUILDING WALLS.
B. PROVIDE DIELECTRIC UNIONS AT CONNECTIONS BETWEEN DISSIMILAR
METALS.
C. REFRIGERANT PIPING SHALL BE ACR COPPER WITH WROUGHT COPPER
FITTINGS CONNECTED WITH SILVER SOLDER.
D. COOLING CONDENSATE DRIP PIPING SHALL BE TYPE "M" COPPER OR
PVC PIPE.
A. WHERE PIPES ARE SUSPENDED, CLEVIS TYPE HANGERS SHALL BE
USED. HANGERS SHALL BE CONSTRUCTED OF STAINLESS STEEL, BE
SIZED TO ACCOMMODATE PIPE AND INSULATION WHERE APPLICABLE,
AND BE DESIGNED TO ALLOW VERTICAL ADJUSTMENT.
B. WHERE INSULATED PIPES PASS THRU HANGERS, SHIELDS SHALL BE
PROVIDED TO PROTECT THE INSULATION. SHIELDS SHALL HAVE BOTTOM
TABS FOR SECURING TO HANGERS.
A. COOLING COIL DRIP PIPING SHALL BE INSULATED WITH 1" THICK
ELASTOMERIC PIPE INSULATION.
B. REFRIGERANT PIPING SHALL BE INSULATED WITH 1" THICK ELASTOMERIC
PIPE INSULATION.
C. RECTANGULAR SUPPLY AND RETURN DUCTS SHALL BE INSULATED WITH
2.2-INCH INSULATION, UNLESS NOTED OTHERWISE.
D. ROUND SUPPLY AND RETURN AIR DUCTS SHALL BE INSULATED WITH
2-INCH THICK FIBERGLASS BLANKET WITH VAPOR BARRIER FOIL.
E. DUCT SIZES INDICATED ARE METAL SIZES.
A. ALL DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN
ACCORDANCE WITH SMACNA.
B. ALL DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL.
ALL ELBOWS SHALL HAVE TURNING VANES.
A. TEST AND ADJUST EACH SYSTEM TO THE SPECIFIED QUANTITY OF
SUPPLY, RETURN, OUTSIDE AIR AND EXHAUST AIR.
B. TEST AND ADJUST EACH AIR DEVICE TO WITHIN 10% OF DESIGN.
GENERAL
IDENTIFICATION
PIPING
HANGERS AND SUPPORTS
INSULATION
DUCTWORK
TEST AND BALANCE
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
VAV BOX SCHEDULE
MARK COOLING
MAX CFM
COOLING
MIN CFM
HEATING
MAX CFM
HEATING
MIN CFM
HOT WATER FLOW
RATE, GPM
VAV-1
VAV-2A
VAV-2B
VAV-3
VAV-4
1.38
1.24
1.24
1.98
2.46
Issue Date02/13/2026
BRIDGING DOCUMENT
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
EL
O
C A
TI
O
N O
F G
IL
ES
C O
U N
TY
A
D M
IN
IS
TR
A
TI
V
E
B O
A R
D R
O O
M R
O O
M
R E
LO
C
A T
IO
N
O F
G
IL
E S
C O
U N
T Y
A D
M
IN
IS
T
R A
T
IV
E B
O A
R D
R O
O M
B O
A R
D R
O O
M R
O O
M R
O O
M R
O O
M R
O
.\TL24x36Sheet-Brandmark_With_Text_Tall_Color_RGB(TIFF)-1235467.tif
Sheet No.
Seal
GI
LE
S
CO
U N
TY
B
O
AR
D
RO
O M
Gi le s C ou nt y, V A
Designed
Drawn
Checked
Date
Project No.
ABC
ABC
MHE
19482
Issue Date
4/ 8/
:5
1:
A M
Da te
/T im e:
Fi le N am e:
Fi le
P at h
N o.
Da te
Pu rp os e of D oc um en t I ss ue
E001
GE
N
ER
AL
N O
TE
S, L
EG
EN
D, A N
D
AB
BR
EV
IA
TI
O N
S
1. ALL NOTES, SYMBOLS AND ABBREVIATIONS MAY NOT BE APPLICABLE TO THIS PROJECT.
2. COMPLY WITH THE FOLLOWING CODES PERTAINING TO THIS PROJECT:
2.1. NATIONAL ELECTRIC CODE/ NFPA 70: NEC, 2020
2.2. VIRGINIA ENERGY CODE: VECC 2021
2.3. VIRGINIA UNIFORM STATEWIDE BUILDING CODE: VUSBC, 2021
2.4. ADA STANDARDS FOR ACCESSIBLE DESIGN, ASAD, TITLE II REGULATIONS, 06/24/2024
3. CONTRACTORS SHALL VISIT SITE TO FAMILIARIZE THEMSELVES WITH CONDITIONS TO BE MET IN THE EXECUTION OF THE WORK UNDER THIS CONTRACT. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR ANY CHANGES THAT MAY BE
REQUIRED DUE TO EXISTING SITE CONDITIONS.
4. PROVIDE INCREASED CONDUCTOR SIZES FOR 120/208 BRANCH CIRCUITS AS FOLLOWS UNO:
CIRCUIT BREAKER 0-100 FT. 100-200 FT. 200-300 FT. OVER 300 FT.
SIZE LENGTH LENGTH LENGTH LENGTH
20 AMP 12 AWG 10 AWG 6 AWG 4 AWG
30 AMP 10 AWG 8 AWG 4 AWG 3 AWG
5. ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FEET SHALL BE PROVIDED WITH A PULLWIRE.
6. DO NOT SHARE NEUTRALS.
7. RECESSED DEVICES MAY BE ADJUSTED TO MATCH MASONRY COURSES IF APPLICABLE. MOUNT ALL BOXES TRUE AND
PLUMB. ADJUSTED MOUNTING HEIGHTS SHALL REMAIN WITHIN ADA REQUIREMENTS.
8. MOUNT RECEPTACLES AT 20" AFF TO TOP, UNLESS OTHERWISE NOTED. ADJUST TO MATCH MASONRY COURSES IF
APPLICABLE WITHIN CODE REQUIREMENTS. MOUNT ALL BOXES TRUE AND PLUMB.
9. RECEPTACLES, SWITCHES, THERMOSTATS, AND OTHER SIMILAR ITEMS SHALL ALIGN VERTICALLY OR HORIZONTALLY WITH
EACH OTHER, WITH THE STRUCTURE AND OTHER FEATURES THEREOF WHEN IT APPEARS OBVIOUS AND LOGICAL THAT THEY SHOULD. THE ELECTRICAL CONTRACTOR SHALL CONSULT WITH THE GENERAL CONSTRUCTION SUPERINTENDENT REGARDING THIS REQUIREMENT AND ALSO FOR THE LOCATION OF EQUIPMENT, DOOR SWINGS, BLOCK COURSING, ALIGNMENT OF THIS AND OTHER SIMILAR FEATURES BEFORE ROUGHING-IN FOR THESE COMPONENTS. ADJUSTED
MOUNTING HEIGHTS SHALL REMAIN WITHIN ADA REQUIREMENTS.
10. THE MANUFACTURER AND MODEL NUMBER SHOWN ON THE LIGHT FIXTURE SCHEDULE INDICATES THE TYPE, CONSTRUCTION, STYLE, QUALITY AND STANDARD OF PERFORMANCE REQUIRED. OTHER MANUFACTURERS WITH EQUAL
PRODUCTS ARE ACCEPTABLE UPON A/E APPROVAL.
11. COORDINATE LIGHTING LAYOUT WITH ARCHITECTURAL CEILING GRID: THE ELECTRICAL CONTRACTOR SHALL VERIFY THE TYPE OF CEILING SYSTEM WITH THE GENERAL CONTRACTOR TO INSURE THAT ALL LIGHTING FIXTURES ARE COMPATIBLE WITH THE CEILING SYSTEM BEING INSTALLED, LIGHTING FIXTURES SHALL NOT BE ORDERED UNTIL THE TYPE OF CEILING
HAS BEEN VERIFIED.
12. CONTRACTOR SHALL VERIFY THAT ALL DOOR SWINGS ARE CORRECT BEFORE ROUGHING IN LIGHT SWITCH OUTLETS.
LIGHT SWITCHES SHALL NOT BE LESS THAN 3 NOR MORE THAN 12 INCHES FROM DOOR TRIM.
13. SUSPENDED LIGHTING FIXTURES SHALL NOT BE SUPPORTED FROM MAIN CHANNELS OR TEES OF CEILING SUSPENSION SYSTEM, SUPPORT FIXTURES INDEPENDENTLY OF CEILING MATERIALS BY BUILDING STRUCTURE.
14. LAY-IN FIXTURES SHALL BE INDEPENDENTLY SUPPORTED BY BUILDING STRUCTURE.
15. EXIT SIGNS SHALL NOT BE INSTALLED AS TO BLOCK FIRE ALARM VISUAL DEVICES. MOUNT WALL MOUNTED EXIT SIGNS
LOCATED ABOVE DOORS, 6-INCHES TO THE BOTTOM OF SIGN FROM TOP OF DOOR FRAME.
16. MOUNT ALL PULL STATIONS 48" AFF TO TOP. MOUNT ALL HORN/STROBES, STROBES AND REMOTE ALARM INDICATORS
SUCH THAT THE TOP OF LENS IS 80" TO 96" AFF, IF 80" AFF IS NOT POSSIBLE, MOUNT TOP OF LENS A MINIMUM OF 6" BELOW CEILING. MOUNT ALL BOXES TRUE AND PLUMB. COORDINATE LOCATION OF FAN CONTROL RELAY WITH MECHANICAL CONTRACTOR. PROVIDE DUCT DETECTORS TO MECHANICAL CONTRACTOR FOR MOUNTING. ALL WIRING BY
THE ELECTRICAL CONTRACTOR. MOUNT ALL BOXES TRUE AND PLUMB.
17. MOUNT ALL WALL MOUNTED TELEPHONE/DATA OUTLETS AT 20" AFF TO TOP, UNLESS OTHERWISE NOTED. ADJUST TO MATCH MASONRY COURSES IF APPLICABLE. FOR WALL MOUNT, PROVIDE A TWO GANG BOX, EXTRA DEEP WITH 2X4 REDUCER PLATE. PROVIDE A 2" CONDUIT AND STUB ABOVE ACCESSIBLE CEILING. TERMINATE CONDUIT ABOVE CEILING WITH INSULATED BUSHING. INSTALL PULL WIRE. ADJUSTED MOUNTING HEIGHTS SHALL REMAIN WITHIN ADA
REQUIREMENTS. ROUGH-IN ONLY SYSTEM, CABLING AND DEVICE BY OTHERS.
18. ALL CONSTRUCTION DESIGN IS BASED ON EXISTING OWNER PROVIDED DRAWINGS AND FIELD INVESTIGATION. THE
CONTRACTOR SHALL VERIFY ALL ASPECTS IN THE FIELD BEFORE STARTING WORK.
19. LOCATIONS OF LINES AND EQUIPMENT SHALL BE DETERMINED FROM ACTUAL FIELD CONDITIONS. THE OUTLINES OF THE CONSTRUCTION SHOWN ON THE ELECTRICAL DRAWINGS ARE INTENDED ONLY AS A GUIDE TO INDICATE RELATIVE LOCATIONS OF THE WORK. REFER TO THE APPLICABLE DRAWINGS OF OTHER TRADES AND THE EQUIPMENT SUPPLIER'S
INSTALLATION DRAWINGS FOR EXACT LOCATIONS AND ARRANGEMENTS.
20. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND PROPER RELATION OF THEIR WORK TO THE FACILITY STRUCTURES AND TO THE WORK OF OTHER TRADES. NO ADDITIONAL COMPENSATION NOR EXTENSION OF COMPLETION TIME WILL BE GRANTED FOR EXTRA WORK CAUSED BY THE LACK OF COORDINATION.
21. COORDINATE WITH MECHANICAL ON EXACT LOCATION AND ELECTRICAL CONNECTION REQUIREMENTS FOR HVAC
EQUIPMENT PROVIDED.
22. ELECTRICAL REQUIREMENTS FOR HVAC EQUIPMENT ARE FOR HVAC EQUIPMENT SPECIFIED. IF SUBSTITUTE HVAC EQUIPMENT IS SUPPLIED, CONTRACTOR IS RESPONSIBLE FOR MODIFICATIONS AND/OR ADDITIONS TO ELECTRICAL
REQUIREMENTS OF HVAC EQUIPMENT SUPPLIED.
23. DUE TO DIFFERENCES IN VARIOUS MANUFACTURER'S EQUIPMENT CONNECTIONS AND MOTOR CURRENTS, THE ELECTRICAL CONTRACTOR SHALL COORDINATE THEIR INSTALLATION WITH THAT EQUIPMENT ACTUALLY FURNISHED AND
SHALL VERIFY THE CORRECT SIZES AND DETAILS OF INSTALLATION BEFORE ROUGHING IN.
24. THE CORRECT NUMBER OF WIRES MAY NOT BE INDICATED FOR ALL CIRCUITS, ONLY THOSE WHERE CLARIFICATION IS NECESSARY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRES NECESSARY FOR THE PROPER FUNCTION OF THE
SYSTEM WHETHER INDICATED ON DRAWINGS OR NOT.
25. LABEL SERVICE SWITCHBOARD/PANEL WITH AVAILABLE FAULT CURRENT IN ACCORDANCE WITH NEC ARTICLE 110.9, 110.10, AND 110.24.
26. LABEL SWITCHBOARDS AND PANELS WITH SOURCE OF POWER IN ACCORDANCE WITH NEC ARTICLE 408.4(B).
27. FOR ALL PANELS MODIFIED IN UNFINISHED SPACED: A 2" WIDE YELLOW LINE SHALL BE PAINTED ON ALL CONCRETE
FLOORS IN ELECTRICAL ROOMS AND CLOSETS INDICATING THE ELECTRICAL WORKING SPACE AROUND ELECTRICAL EQUIPMENT AS DEFINED BY THE NEC. THE DEFINED SPACE SHALL BE 30" WIDE (OR THE WIDTH OF THE ACTUAL EQUIPMENT, WHICHEVER IS GREATER) X 36" DEEP FOR ALL EQUIPMENT LESS THAN 600V TO GROUND. STENCIL "NO STORAGE-ELECTRICAL WORKING SPACE" IN 2" HIGH YELLOW LETTERS CENTERED IN THE SPACE OUTLINED AREA.
28. PROVIDE LABELS FOR BRANCH CIRCUITS WITH SPACE AND ROOM NUMBERS THAT THE CIRCUIT FEEDS TO FOR EXISTING SWITCHBOARDS, MCC, AND PANEL BOARDS THAT ARE MODIFIED AS A PART OF THIS PROJECT IN ACCORDANCE WITH NEC
408.4. ALL PANEL SCHEDULES WHERE EQUIPMENT HAS BEEN MODIFIED AS A PART OF THIS PROJECT SHALL BE UPDATED WITH A TYPED SCHEDULE. SUBMIT UPDATED PANEL SCHEDULE FOR APPROVAL TO THE ENGINEER OF RECORD PRIOR TO
FINAL INSPECTION. PROVIDE ALL REVISIONS DURING CONSTRUCTION IN AS-BUILT PLANS.
WALL MOUNTED EXIT SIGN. SHADING INDICATES FACE AND ARROWS INDICATE
DIRECTIONAL ARROWS WHERE SHOWN. SEE LIGHT FIXTURE SCHEDULE.
WALL MOUNTED LIGHT FIXTURE, TYPE AS INDICATED. SEE LIGHT FIXTURE SCHEDULE. NL INDICATES
UNSWITCHED NIGHT LIGHT.
RECESSED/SURFACE MOUNTED LIGHT FIXTURE, TYPE AS INDICATED. SEE LIGHT FIXTURE
SCHEDULE.
SHADING OR "EM" DENOTES FIXTURE WITH INTEGRAL EMERGENCY BATTERY FOR
EMERGENCY EGRESS LIGHTING. INTEGRAL BATTERY WHERE USED SHALL BE POWERED
AT ALL TIMES. WHERE FIXTURES INDICATED TO BE SWITCHED, PROVIDE EMERGENCY
SHUNT RELAY TO TURN FIXTURE ON WITH THE LOSS OF POWER REGARDLESS OF
SWITCH POSITION. SEE LIGHT FIXTURE SCHEDULE.
CIRCULAR DOWNLIGHT, TYPE AS INDICATED. SEE LIGHT FIXTURE SCHEDULE.
CEILING MOUNTED EXIT SIGN. SHADING INDICATES FACE AND ARROWS INDICATE
DIRECTIONAL ARROWS WHERE SHOWN. SEE LIGHT FIXTURE SCHEDULE.
LIGHT SWITCH, SINGLE POLE DEVICE, 20 AMP, 120/277 VOLT, FLUSH MOUNT 48" AFF TO TOP OF
BOX. "D" INDICATES DIMMER SWITCH.
LIGHT SWITCH, SINGLE POLE DEVICE, 20 AMP, 120/277 VOLT, SURFACE MOUNT 48" AFF TO TOP OF
BOX. "D" INDICATES DIMMER SWITCH.
LIGHT SWITCH, SINGLE POLE DEVICE WITH INTEGRAL OCCUPANCY SENSOR, 20 AMP, 120/277
VOLT, FLUSH MOUNT 48" AFF TO TOP OF BOX. "OS" INDICATES OCCUPANCY SENSOR. "VS"
INDICATES VACANCY SENSOR.
CEILING MOUNTED SENSOR "OS" INDICATES OCCUPANCY SENSOR. "VS" INDICATES VACANCY
SENSOR. "PC" INDICATES ANALOG PHOTOCELL LIGHT-LEVEL SENSOR.
120 V, 20 AMP, DUPLEX CONVENIENCE RECEPTACLE, FLUSH MOUNT 20" AFF TO
TOP OF BOX, NEMA 5-20R. "GFI" INDICATES GROUND FAULT INTERRUPTION
TYPE. "WP" INDICATES WEATHER PROOF WHILE CLOSED COVER.
120 V, 20 AMP, DUPLEX CONVENIENCE RECEPTACLE, FLUSH MOUNT 48" AFF
TO TOP OF BOX, OR 6" ABOVE COUNTERTOP OR BACKSPLASH AS APPLICABLE
TO TOP OF BOX. "GFI" INDICATES GROUND FAULT INTERRUPTION TYPE. "WP"
INDICATES WEATHER PROOF WHILE CLOSED COVER.
120 V, 20 AMP, DUPLEX CONVENIENCE RECEPTACLE, SURFACE MOUNT BOX 20"
AFF TO TOP OF BOX, NEMA 5-20R.
120 V, 20 AMP, DOUBLE DUPLEX RECEPTACLE, NEMA 5-20R FLUSH MOUNT 48" AFF TO TOP
OF BOX OR 6" ABOVE COUNTERTOP OR BACKSPLASH AS POSSIBLE. SINGLE COVER PLATE.
FLOOR BOX FOR POWER AND DATA FOR ACCESS FLOOR. TYPE AS INDICATED ON PLANS.
CEILING JUNCTION BOX FOR POWER AND DATA
SPECIAL PURPOSE RECEPTACLE, FLUSH MOUNT. TYPE AS INDICATED ON PLANS.
JUNCTION BOX / PULL BOX
ELECTRIC MOTOR, HP/KW, VOLTAGE, AND PHASE AS INDICATED
MAGNETIC MOTOR STARTER WITH OVERLOADS & DISCONNECT SWITCH
MANUAL MOTOR STARTER WITH OVERLOAD PROTECTION, SURFACE MOUNT
SAFETY SWITCH, HEAVY DUTY, FUSIBLE OR NON-FUSIBLE, POLES AS
REQUIRED, "F" INDICATES FUSIBLE.
DUAL DATA/TELEPHONE OUTLET. MOUNT AT 20" AFF TO TOP, UNO. PROVIDE A TWO GANG BOX, EXTRA DEEP WITH 2x4 REDUCER PLATE. PROVIDE A 2" CONDUIT TO ABOVE ACCESSIBLE CEILING, TERMINATE ABOVE CEILING WITH INSULATED BUSHING. "C" INDICATES 48" AFF OR 6" ABOVE COUNTER TO TOP OF BOX. ROUGH-IN ONLY SYSTEM, CABLING AND DEVICE BY OTHERS. "TV" INDICATES MOUNTED 60" AFF OR
AS DIRECTED BY OWNER FOR USE WITH TELEVISION.
3/4"X4'X8' PLYWOOD TELEPHONE/DATA BACKBOARD, PAINTED WITH FIRE RESISTANT PAINT. PROVIDE GROUND BAR ON BACKBOARD. PROVIDE #6 GROUNDING CONDUCTOR CONNECTION BETWEEN EQUIPMENT
CONDUITS AND GROUND BAR.
PANEL BOARD, NEW. DASHED LINE INDICATES NEC REQUIRED CLEARANCE.
A, AMP AMPERE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AWG AMERICAN WIRE GAUGE
BKR BREAKER
C CONDUIT
CCTV CLOSED CIRCUIT TELEVISION
CT CURRENT TRANSFORMER
CU COPPER
EF EXHAUST FAN
EM EMERGENCY
EUH ELECTRIC UNIT HEATER
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EX EXISTING TO REMAIN
FA FIRE ALARM
FT FEET
GEC GROUND ELECTRODE CONDUCTOR
GFI, GFCI GROUND FAULT (CIRCUIT) INTERRUPTER
GND, G GROUND
HP HORSEPOWER
HSP HAND STARTER WITH PILOT LIGHT
HVAC HEATING, VENTILATION AND AIR CONDITIONING
JB JUNCTION BOX
KVA KILOVOLT AMPERE
KW KILOWATT
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MLO MAIN LUG ONLY
MM MILLIMETER
MSB MAIN SWITCHBOARD
N NEUTRAL
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL MANUF. ASSOC.
NL NIGHT LIGHT
OL OVERLOAD
PB PUSHBUTTON MOMENTARY CONTACT SWITCH
PC PHOTOELECTRIC CELL
PNL PANEL
RGS RIGID GALVANIZED STEEL CONDUIT
RTU ROOF TOP UNIT
SWB SWITCHBOARD
TC TIME CLOCK
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
TW TEST WELL
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
WC WATER COOLER
WG WIRE GUARD
WP WEATHERPROOF
XFMR TRANSFORMER
CIRCUIT HOME RUN AND CONNECTION TO DEVICE (PANEL A, CIRCUIT #1), ARROW HEADS
INDICATE NUMBER OF CIRCUITS. PANEL DESIGNATION AS INDICATED. BRANCH CONDUCTORS
ARE #12 AWG COPPER IN 3/4" RACEWAY MINIMUM, UNO. DASHED LINE DENOTES
UNDERGROUND OR UNDER FLOOR CIRCUITS.
LEGENDGENERAL ELECTRICAL NOTES
PANEL BOARD, EXISTING. DASHED LINE INDICATES NEC REQUIRED CLEARANCE.
TRANSFORMER, NAME AS INDICATED
CARD READER, FLUSH MOUNTED AT 48" TO TOP UNO.
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
DUCT DETECTOR
FIRE ALARM MANUAL PULL STATION. FLUSH MOUNT 48" AFF TO TOP OF BOX.
VIDEO CAMERA, MOUNT 8'-0" AFF, UNO. PROVIDE A TWO GANG BOX, EXTRA DEEP WITH 2X4 REDUCER PLATE.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .