19114 Drawings.pdf
PDF 449 KB Posted
- Solicitation number
- RFQ 171 250000000052 2
- Issued by
- Livingston County, Michigan
About this file
This is a set of architectural drawings prepared by the State of Michigan Department of Technology, Management and Budget for alterations at the Newberry Correctional Facility Administration Building. The project involves the construction of a new body scanner room with associated visiting room modifications at the facility located at 13747 County Road 428, Newberry, Michigan 49868. The scope of work includes the creation of approximately 1,469 square feet of alteration space within the 23,437 gross square foot administration building. Key construction elements include framing new rooms with metal studs and gypsum board, installing hollow metal doors and frames, modifying HVAC ductwork and grilles, relocating electrical receptacles and light fixtures, installing new plumbing for a water cooler connection, and replacing floor finishes with vinyl composition tile. The drawings were released for bids on November 4, 2024, following owner review on October 21, 2024. The project is classified as Type II-B construction with Occupancy Group B and requires compliance with the 2015 Michigan Rehabilitation Code (Alterations Level 2), 2021 Michigan Mechanical Code, 2021 Michigan Plumbing Code, and 2023 National Electrical Code.
The contractor must procure all materials before commencing work to minimize project duration and is responsible for abatement of existing composition tile flooring through a company certified in hazardous materials removal. Construction storage is prohibited inside the building; all materials and tools must be stored in secure trailers outside the facility. The work area must be roped off with caution tape when work is not occurring. The owner will remove and reinstall the existing body scanner equipment before and after contract work. The facility has spare LED light fixtures available for reuse at new fixture locations. No specific pricing, set-aside information, or contract term details are provided in the drawings document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 19114 - Addendum 1.pdf | ||
| 19114 Advertisment.pdf | ||
| 19114 Specifications.pdf | ||
| CAJ-1037 MDOC LEIN Request REV 09-2019.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
'-0
5"
11' -2
'-0
11'-0"±
NEW ADANI CONPASS SCANNER (BY OWNER)
OWNER TO DISASSEMBLE AND REASSEMBLE.
MODIFY EXISTING DUCT AND EXTEND TO NEW GRILLE LOCATION
PATCH EXISTING CEILING IN BATHROOM AS NEEDED, PAINT WALL (AND CEILING).
REMOVE EXISTING GRILLE,
REMOVE ATTACHED DUCT AND
FILL HOLE WITH CONC.
MASONRY AND PAINT WALL.
RELOCATE EXISTING
WATER COOLER. REMOVE
AND CAP EXISTING PIPING,
PATCH HOLES. REMOVE
RECEPTACLE, PAINT WALL.
REINSTALL EXISTING WATER COOLER.
INSTALL NEW 12" CW SUPPLY AND WASTE PIPE, CONNECT TO
EXISTING RESTROOM PLUMBING. ADD SHUTOFF VALVE AND ELECTRICAL
RECEPTACLE.
REMOVE EXISTING WATER LINE,
PATCH HOLE IN FLOOR
EXISTING RECEPTACLE AND
ASSOCIATED CONDUIT TO REMAIN
EXISTING RECEPTACLE AND
ASSOCIATED CONDUIT TO REMAIN
REMOVE EXISTING RECEPTACLE AND ASSOCIATED CONDUIT BACK TO
NEXT JUNCTION BOX OR ELECTRICAL PANEL, PATCH HOLES, PAINT WALLS.
EXISTING LIVE CIRCUIT CONDUITS TO REMAIN
REMOVE ABANDONED CONDUITS AND BOXES, PATCH HOLES, PAINT WALL.
VISITING ROOM
V.R. BATHROOM
PSYCHOLOGY
OFFICE SCANNER ROOM
CONTROL ROOM
EXISTING THERMOSTATS TO REMAIN
M
IN
1'- 4"
3'-0"
NEW OPERATOR DESK (BY OWNER)
36"x84" HOLLOW METAL DOOR AND FRAME
36"x84" HOLLOW METAL DOOR
AND FRAME, SEE DETAILS 4 AND 5/A8.
36"x84" HOLLOW METAL DOOR
AND FRAME. SEE DETAILS 4 AND 5/A8.
8" GYPSUM BOARD, 3 5 8" METAL STUDS AT 16" O.C.,
8" GYPSUM BOARD - EXTEND TO UNDERSIDE OF ROOF DECK SEE
SECTION 3/A8, PAINT WALLS.
8" GYPSUM BOARD, 35
8" METAL STUDS AT
16" O.C., 5 8" GYPSUM BOARD - EXTEND TO
UNDERSIDE OF ROOF DECK. PAINT WALLS.
EXISTING 8" CMU AND 4" BRICK
COMPOSITE WALL
ABATE ALL FLOOR TILE AND
INSTALL NEW VCT TILE.
INSTALL NEW RESILIENT
WALL BASE.
NEW 48"w X 48"h HOLLOW
METAL BORROWED LIGHT
WITH 3 8" CLEAR LAMINATED
POLYCARBONATE GLAZING
A1
NEW RECEPTACLE
NEW RECEPTACLE
NEW RECEPTACLE
CONTINUOUS EPOXY SEALANT AT JOINT BETWEEN MASONRY AND GYPSUM BOARD, TYPICAL ALL LOCATIONS
38'-812"±
'-1 2"
CORRIDOR
EXISTING BUBBLE GATE
EXISTING INNER GATE
V.R. BATHROOM
CONTROL
CENTER6
'-0
5"
11' -2
'-0
11'-0"±
REMOVE AND RELOCATE EXISTING LED LIGHT FIXTURE
REMOVE AND RELOCATE EXISTING LED LIGHT FIXTURE
RELOCATE EXISTING DIFFUSER,
MODIFY DUCT CONNECTION AS NECESSARY TO NEW LOCATION
REMOVE AND RELOCATE EXISTING GRILLE
MODIFY DUCT CONNECTION AS NEEDED FOR NEW GRILLE RELOCATION
EXISTING RECESSED LED LIGHT FIXTURE RELOCATED
EXISTING RECESSED LED LIGHT FIXTURE RELOCATED
INSTALL NEW 24"x24" CEILING GRILLE AND NEW 12"x20" DUCT TO IT.
SAWCUT OPENING THROUGH CMU WALL FOR DUCT. INSTALL NEW
RETURN DUCT ABOVE CEILING TO EXISTING RETURN DUCT ABOVE
RESTROOM CEILING.
EXISTING CEILING CAMERA TO REMAIN
VISITING ROOM
V.R. BATHROOM
PSYCHOLOGY
OFFICE SCANNER ROOM
CONTROL ROOM
M
IN
1'- 4"
3'-0"
REMOVE EXISTING CEILING AND GRID IN AREA OF NEW
ROOMS. PATCH EXISTING CEILING GRID AND INSTALL
NEW PADS IN REMOVED AREAS.
INSTALL NEW CEILING AND
CEILING GRID AT 9'-0" ABOVE
FINISHED FLOOR
A1
38'-812"±
'-1 2"
NEW LED LIGHT FIXTURE
FURNISHED BY THE FACILITY
EXISTING CEILING GRID AND PADS TO REMAIN.
EXISTING CEILING HEIGHT = 9'-0"±
EXISTING GYPSUM
BOARD SOFFIT
EXISTING ACOUSTICAL CEILING
CEILING HEIGHT 8'-0" ±
CORRIDOR
EXISTING BUBBLE GATE
EXISTING INNER GATE
V.R. BATHROOM
CONTROL
CENTER
ADD NEW DIFFUSER TO MATCH EXISTING AND INSTALL NEW 6" DIAMETER DUCT TO
NEAREST SUPPLY DUCT. CUT IN OPENING AT EXISTING DUCT AND INSTALL A
VOLUME DAMPER AT BRANCH DUCT. BALANCE AT 100 CFM.
NEW LIGHT SWITCH FOR LIGHT IN CONTROL ROOM.
INSTALL ASSOCIATED CONDUIT AND WIRING TO BOTH.
NEW LIGHT SWITCH FOR LIGHT IN SCANNER ROOM.
INSTALL ASSOCIATED CONDUIT AND WIRING TO BOTH.
EXISTING HARD CEILING WITH ACCESS PANEL
CUT AND PATCH EXISTING GWB CEILING AS NECESSARY TO INSTALL
NEW DUCTWORK. PAINT GEW TO MATCH EXISTING.
CUT AND PATCH
CEILING AS NECESSARY
FOR DUCTWORK
MODIFICATIONS
DEFLECTION TRACK - ALLOW 1" DEFLECTION
DO NOT FASTEN TO RUNNER
CONTINUOUS RUNNER
EXISTING METAL ROOF DECK , INSULATION AND
ROOFING TO REMAIN
8" GYPSUM BOARD ON EACH SIDE
8" GYPSUM BOARD
APPLIED RESILIENT BASE
VINYL TILE FLOORING OVER EXISTING CONCRETE
SLAB FLOOR
8" METAL STUDS AT 16" O.C. - MIN. 20 GAGE STUDS
'-0
METAL ANGLE OR CHANNEL BRACE AT MID-HEIGHT.
FASTEN TO EACH STUD WITH CLIP ANGLES OR MANUFACTURER
APPROVED METHOD.
HOLLOW METAL
DOOR AND FRAME
EXTEND GYPSUM
TO BACK OF METAL FRAME
GYPSUM BOARD
SCANNER ROOM
RUNNER
14 GAUGE HOLLOW METAL
DOOR FRAME.
14 GAUGE HOLLOW METAL DOOR,
STEEL STIFFENERS INSIDE DOOR.
8" GYPSUM BOARD.
8" GYPSUM BOARD
SCANNER
ROOM
MAIN ENTRANCE
AREA OF WORK
FIRE
SEPARATION
WALL
FIRE
SEPARATION
WALL
3'-0"
7"
7'-
7" 3' -0
8" LAMINATED
POLYCARBONATE
GLAZING
14" GAGE METAL
DOOR FACE WITH
METAL STAVES
FLOOR PLAN
SCALE: 1/4" = 1'-0"
REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
WALL SECTION
SCALE: 1" = 1'-0"
JAMB DETAIL
SCALE: 1-1/2" = 1'-0"
HEAD DETAIL
SCALE: 1-1/2" = 1'-0"
A1
A1
A1
A1
A1
NOTES;
METAL STUDS: 20 GAUGE AT 16" O.C. INSTALL RUNNERS OF THE SAME WIDTH TO THE
FLOOR WITH TAPCON CONCRETE SCREWS AND WASHERS AT MAXIMUM 4'-0" O.C. INSTALL
A DEFLECTION CHANNEL AT THE UNDERSIDE OF THE ROOF DECK (MINIMUM 1" DEFLECTION).
DO NOT ATTACH TOP RUNNER TO DEFLECTION CHANNEL TO PERMIT MOVEMENT. DO NOT
FASTEN GYPSUM BOARD TO EITHER TOP RUNNER OR DEFLECTION CHANNEL TO PERMIT
MOVEMENT.
SEAL JOINTS BETWEEN MASONRY AND GYPSUM BOARD; AND METAL AND GYPSUM
BOARD WITH EPOXY, NO-PICK SEALANT. SEALANT AT GLAZING TO BE SILICONE.
FURNISH AND INSTALL 1 8" VINYL COMPOSITION TILE. COLOR SELECTED FROM
MANUFACTURER'S STANDARD COLORS. ADHERE TO CONCRETE SLAB WITH
MANUFACTURER'S RECOMMENDED ADHESIVE.
FURNISH AND INSTALL 4" HIGH RUBBER BASE. COLOR SELECTED FROM MANUFACTURER'S
STANDARD COLORS. INSTALL BASE WITH ADHESIVE AS RECOMMENDED BY
MANUFACTURER. MITER CORNERS.
NEW CEILING GRID TO MATCH EXISTING 15 16" CEILING GRID IN MATERIAL AND COLOR. MATCH
EXISTING CEILING PANELS.
NEW ELECTRICAL RECEPTACLES SHALL HAVE A REDUNDANT GROUND CONNECTION.
CONDUIT TO ME EMT INSIDE WALLS AND ABOVE CEILING. USE RIGID CONDUIT WITH
DOUBLE STRAPS AT 36" O.C. IF INSTALLED ON WALL SURFACE.
CONNECT NEW RECEPTACLES IN 2 CIRCUITS (CONVENIENCE CIRCUIT AND WATER COOLER
CIRCUIT) TO THE POWER PANEL SERVING THIS ROOM.
REUSE EXISTING LED LIGHT FIXTURES. FACILITY HAS SPARES TO USE FOR NEW FIXTURE
LOCATION.
OWNER WILL RELOCATE THE EXISTING BODY SCANNER OUT OF THE ROOM FOR
CONTRACT WORK AND OWNER WILL REINSTALL AFTER THE WORK IS SUBSTANTIALLY
COMPLETE.
BEFORE WORK BEGINS, THE CONTRACTOR SHALL PROCURE ALL MATERIALS TO BE USED
ON THIS PROJECT IN ORDER TO COMPLETE THE WORK AFTER STARTING IN THE SHORTEST
AMOUNT OF TIME.
CONTRACTOR SHALL INCLUDE IN THEIR WORK ABATEMENT OF THE EXISTING
COMPOSITION TILE FLOOR. THE CONTRACTOR SHALL EMPLOY A COMPANY CERTIFIED TO
ABATE HAZARDOUS MATERIALS FOR THIS WORK.
CONTRACTOR TO ROPE OFF WITH CAUTION TAPE THE WORK AREA WHEN WORK IS NOT
OCCURRING.
NO CONSTRUCTION STORAGE WILL BE PERMITTED INSIDE THE BUILDING. THIS INCLUDES
CONSTRUCTION MATERIALS AND TOOLS. THESE ARE TO BE STORED IN SECURE TRAILER(S)
OUTSIDE OF THE BUILDING.
P e t t i t t Y a s t e
S t r a u b
200S
LAWSON,C MICHIGAN
UITE
48017-1311
F A X248-658-7781 248-658-7777 P H O N E
C850 NORTH ROOKS ROAD
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I
Q U
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
A1 OF 1
RELEASED FOR BIDS 11/04/24
OWNER REVIEW 10/21/24
ADMINISTRATION BUILDING
VISITING ROOM - NEW BODY
SCANNER ROOM
NEWBERRY CORRECTIONAL
FACILITY
NEW BODY SCANNER ROOM
FILE NO: 472/19114.ABG
ACCT.NO:472NCFMaintProj
ADMINISTRATION BLDG
SCALE: 1/64" = 1'-0"
CODE DATA:
MICHIGAN REHABILITATION CODE - 2015 - ALTERATIONS LEVEL 2
MICHIGAN MECHANICAL CODE - 2021
MICHIGAN PLUMBING CODE - 2021
NATIONAL ELECTRICAL CODE - 2023
ADMINISTRATION BUILDING AREA = 23,437 gsf AREA OF ALTERATION WORK: 1469 sf
TYPE II-B CONSTRUCTION
OCCUPANCY GROUP B
NO FIRE SUPPRESSION
DOOR ELEVATION
SCALE: 1/2" = 1'-0"A1
AutoCAD SHX Text
13747 COUNTY ROAD 428 NEWBERRY, MI 49868
| Sheets and Views |
| XRay Room |
File details come from the government source that posted it. Updated .