19114 Drawings.pdf

PDF 449 KB Posted

Attached to
472/19114. ABG; Newberry Upgrade Perimater Security Head End
Solicitation number
RFQ 171 250000000052 2
Issued by
Livingston County, Michigan

About this file

This is a set of architectural drawings prepared by the State of Michigan Department of Technology, Management and Budget for alterations at the Newberry Correctional Facility Administration Building. The project involves the construction of a new body scanner room with associated visiting room modifications at the facility located at 13747 County Road 428, Newberry, Michigan 49868. The scope of work includes the creation of approximately 1,469 square feet of alteration space within the 23,437 gross square foot administration building. Key construction elements include framing new rooms with metal studs and gypsum board, installing hollow metal doors and frames, modifying HVAC ductwork and grilles, relocating electrical receptacles and light fixtures, installing new plumbing for a water cooler connection, and replacing floor finishes with vinyl composition tile. The drawings were released for bids on November 4, 2024, following owner review on October 21, 2024. The project is classified as Type II-B construction with Occupancy Group B and requires compliance with the 2015 Michigan Rehabilitation Code (Alterations Level 2), 2021 Michigan Mechanical Code, 2021 Michigan Plumbing Code, and 2023 National Electrical Code.

The contractor must procure all materials before commencing work to minimize project duration and is responsible for abatement of existing composition tile flooring through a company certified in hazardous materials removal. Construction storage is prohibited inside the building; all materials and tools must be stored in secure trailers outside the facility. The work area must be roped off with caution tape when work is not occurring. The owner will remove and reinstall the existing body scanner equipment before and after contract work. The facility has spare LED light fixtures available for reuse at new fixture locations. No specific pricing, set-aside information, or contract term details are provided in the drawings document.

View the file

Other files

File Type Posted
19114 - Addendum 1.pdf PDF
19114 Advertisment.pdf PDF
19114 Specifications.pdf PDF
CAJ-1037 MDOC LEIN Request REV 09-2019.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

'-0

5"

11' -2

'-0

11'-0"±

NEW ADANI CONPASS SCANNER (BY OWNER)

OWNER TO DISASSEMBLE AND REASSEMBLE.

MODIFY EXISTING DUCT AND EXTEND TO NEW GRILLE LOCATION

PATCH EXISTING CEILING IN BATHROOM AS NEEDED, PAINT WALL (AND CEILING).

REMOVE EXISTING GRILLE,

REMOVE ATTACHED DUCT AND

FILL HOLE WITH CONC.

MASONRY AND PAINT WALL.

RELOCATE EXISTING

WATER COOLER. REMOVE

AND CAP EXISTING PIPING,

PATCH HOLES. REMOVE

RECEPTACLE, PAINT WALL.

REINSTALL EXISTING WATER COOLER.

INSTALL NEW 12" CW SUPPLY AND WASTE PIPE, CONNECT TO

EXISTING RESTROOM PLUMBING. ADD SHUTOFF VALVE AND ELECTRICAL

RECEPTACLE.

REMOVE EXISTING WATER LINE,

PATCH HOLE IN FLOOR

EXISTING RECEPTACLE AND

ASSOCIATED CONDUIT TO REMAIN

EXISTING RECEPTACLE AND

ASSOCIATED CONDUIT TO REMAIN

REMOVE EXISTING RECEPTACLE AND ASSOCIATED CONDUIT BACK TO

NEXT JUNCTION BOX OR ELECTRICAL PANEL, PATCH HOLES, PAINT WALLS.

EXISTING LIVE CIRCUIT CONDUITS TO REMAIN

REMOVE ABANDONED CONDUITS AND BOXES, PATCH HOLES, PAINT WALL.

VISITING ROOM

V.R. BATHROOM

PSYCHOLOGY

OFFICE SCANNER ROOM

CONTROL ROOM

EXISTING THERMOSTATS TO REMAIN

M

IN

1'- 4"

3'-0"

NEW OPERATOR DESK (BY OWNER)

36"x84" HOLLOW METAL DOOR AND FRAME

36"x84" HOLLOW METAL DOOR

AND FRAME, SEE DETAILS 4 AND 5/A8.

36"x84" HOLLOW METAL DOOR

AND FRAME. SEE DETAILS 4 AND 5/A8.

8" GYPSUM BOARD, 3 5 8" METAL STUDS AT 16" O.C.,

8" GYPSUM BOARD - EXTEND TO UNDERSIDE OF ROOF DECK SEE

SECTION 3/A8, PAINT WALLS.

8" GYPSUM BOARD, 35

8" METAL STUDS AT

16" O.C., 5 8" GYPSUM BOARD - EXTEND TO

UNDERSIDE OF ROOF DECK. PAINT WALLS.

EXISTING 8" CMU AND 4" BRICK

COMPOSITE WALL

ABATE ALL FLOOR TILE AND

INSTALL NEW VCT TILE.

INSTALL NEW RESILIENT

WALL BASE.

NEW 48"w X 48"h HOLLOW

METAL BORROWED LIGHT

WITH 3 8" CLEAR LAMINATED

POLYCARBONATE GLAZING

A1

NEW RECEPTACLE

NEW RECEPTACLE

NEW RECEPTACLE

CONTINUOUS EPOXY SEALANT AT JOINT BETWEEN MASONRY AND GYPSUM BOARD, TYPICAL ALL LOCATIONS

38'-812"±

'-1 2"

CORRIDOR

EXISTING BUBBLE GATE

EXISTING INNER GATE

V.R. BATHROOM

CONTROL

CENTER6

'-0

5"

11' -2

'-0

11'-0"±

REMOVE AND RELOCATE EXISTING LED LIGHT FIXTURE

REMOVE AND RELOCATE EXISTING LED LIGHT FIXTURE

RELOCATE EXISTING DIFFUSER,

MODIFY DUCT CONNECTION AS NECESSARY TO NEW LOCATION

REMOVE AND RELOCATE EXISTING GRILLE

MODIFY DUCT CONNECTION AS NEEDED FOR NEW GRILLE RELOCATION

EXISTING RECESSED LED LIGHT FIXTURE RELOCATED

EXISTING RECESSED LED LIGHT FIXTURE RELOCATED

INSTALL NEW 24"x24" CEILING GRILLE AND NEW 12"x20" DUCT TO IT.

SAWCUT OPENING THROUGH CMU WALL FOR DUCT. INSTALL NEW

RETURN DUCT ABOVE CEILING TO EXISTING RETURN DUCT ABOVE

RESTROOM CEILING.

EXISTING CEILING CAMERA TO REMAIN

VISITING ROOM

V.R. BATHROOM

PSYCHOLOGY

OFFICE SCANNER ROOM

CONTROL ROOM

M

IN

1'- 4"

3'-0"

REMOVE EXISTING CEILING AND GRID IN AREA OF NEW

ROOMS. PATCH EXISTING CEILING GRID AND INSTALL

NEW PADS IN REMOVED AREAS.

INSTALL NEW CEILING AND

CEILING GRID AT 9'-0" ABOVE

FINISHED FLOOR

A1

38'-812"±

'-1 2"

NEW LED LIGHT FIXTURE

FURNISHED BY THE FACILITY

EXISTING CEILING GRID AND PADS TO REMAIN.

EXISTING CEILING HEIGHT = 9'-0"±

EXISTING GYPSUM

BOARD SOFFIT

EXISTING ACOUSTICAL CEILING

CEILING HEIGHT 8'-0" ±

CORRIDOR

EXISTING BUBBLE GATE

EXISTING INNER GATE

V.R. BATHROOM

CONTROL

CENTER

ADD NEW DIFFUSER TO MATCH EXISTING AND INSTALL NEW 6" DIAMETER DUCT TO

NEAREST SUPPLY DUCT. CUT IN OPENING AT EXISTING DUCT AND INSTALL A

VOLUME DAMPER AT BRANCH DUCT. BALANCE AT 100 CFM.

NEW LIGHT SWITCH FOR LIGHT IN CONTROL ROOM.

INSTALL ASSOCIATED CONDUIT AND WIRING TO BOTH.

NEW LIGHT SWITCH FOR LIGHT IN SCANNER ROOM.

INSTALL ASSOCIATED CONDUIT AND WIRING TO BOTH.

EXISTING HARD CEILING WITH ACCESS PANEL

CUT AND PATCH EXISTING GWB CEILING AS NECESSARY TO INSTALL

NEW DUCTWORK. PAINT GEW TO MATCH EXISTING.

CUT AND PATCH

CEILING AS NECESSARY

FOR DUCTWORK

MODIFICATIONS

DEFLECTION TRACK - ALLOW 1" DEFLECTION

DO NOT FASTEN TO RUNNER

CONTINUOUS RUNNER

EXISTING METAL ROOF DECK , INSULATION AND

ROOFING TO REMAIN

8" GYPSUM BOARD ON EACH SIDE

8" GYPSUM BOARD

APPLIED RESILIENT BASE

VINYL TILE FLOORING OVER EXISTING CONCRETE

SLAB FLOOR

8" METAL STUDS AT 16" O.C. - MIN. 20 GAGE STUDS

'-0

METAL ANGLE OR CHANNEL BRACE AT MID-HEIGHT.

FASTEN TO EACH STUD WITH CLIP ANGLES OR MANUFACTURER

APPROVED METHOD.

HOLLOW METAL

DOOR AND FRAME

EXTEND GYPSUM

TO BACK OF METAL FRAME

GYPSUM BOARD

SCANNER ROOM

RUNNER

14 GAUGE HOLLOW METAL

DOOR FRAME.

14 GAUGE HOLLOW METAL DOOR,

STEEL STIFFENERS INSIDE DOOR.

8" GYPSUM BOARD.

8" GYPSUM BOARD

SCANNER

ROOM

MAIN ENTRANCE

AREA OF WORK

FIRE

SEPARATION

WALL

FIRE

SEPARATION

WALL

3'-0"

7"

7'-

7" 3' -0

8" LAMINATED

POLYCARBONATE

GLAZING

14" GAGE METAL

DOOR FACE WITH

METAL STAVES

FLOOR PLAN

SCALE: 1/4" = 1'-0"

REFLECTED CEILING PLAN

SCALE: 1/4" = 1'-0"

WALL SECTION

SCALE: 1" = 1'-0"

JAMB DETAIL

SCALE: 1-1/2" = 1'-0"

HEAD DETAIL

SCALE: 1-1/2" = 1'-0"

A1

A1

A1

A1

A1

NOTES;

METAL STUDS: 20 GAUGE AT 16" O.C. INSTALL RUNNERS OF THE SAME WIDTH TO THE

FLOOR WITH TAPCON CONCRETE SCREWS AND WASHERS AT MAXIMUM 4'-0" O.C. INSTALL

A DEFLECTION CHANNEL AT THE UNDERSIDE OF THE ROOF DECK (MINIMUM 1" DEFLECTION).

DO NOT ATTACH TOP RUNNER TO DEFLECTION CHANNEL TO PERMIT MOVEMENT. DO NOT

FASTEN GYPSUM BOARD TO EITHER TOP RUNNER OR DEFLECTION CHANNEL TO PERMIT

MOVEMENT.

SEAL JOINTS BETWEEN MASONRY AND GYPSUM BOARD; AND METAL AND GYPSUM

BOARD WITH EPOXY, NO-PICK SEALANT. SEALANT AT GLAZING TO BE SILICONE.

FURNISH AND INSTALL 1 8" VINYL COMPOSITION TILE. COLOR SELECTED FROM

MANUFACTURER'S STANDARD COLORS. ADHERE TO CONCRETE SLAB WITH

MANUFACTURER'S RECOMMENDED ADHESIVE.

FURNISH AND INSTALL 4" HIGH RUBBER BASE. COLOR SELECTED FROM MANUFACTURER'S

STANDARD COLORS. INSTALL BASE WITH ADHESIVE AS RECOMMENDED BY

MANUFACTURER. MITER CORNERS.

NEW CEILING GRID TO MATCH EXISTING 15 16" CEILING GRID IN MATERIAL AND COLOR. MATCH

EXISTING CEILING PANELS.

NEW ELECTRICAL RECEPTACLES SHALL HAVE A REDUNDANT GROUND CONNECTION.

CONDUIT TO ME EMT INSIDE WALLS AND ABOVE CEILING. USE RIGID CONDUIT WITH

DOUBLE STRAPS AT 36" O.C. IF INSTALLED ON WALL SURFACE.

CONNECT NEW RECEPTACLES IN 2 CIRCUITS (CONVENIENCE CIRCUIT AND WATER COOLER

CIRCUIT) TO THE POWER PANEL SERVING THIS ROOM.

REUSE EXISTING LED LIGHT FIXTURES. FACILITY HAS SPARES TO USE FOR NEW FIXTURE

LOCATION.

OWNER WILL RELOCATE THE EXISTING BODY SCANNER OUT OF THE ROOM FOR

CONTRACT WORK AND OWNER WILL REINSTALL AFTER THE WORK IS SUBSTANTIALLY

COMPLETE.

BEFORE WORK BEGINS, THE CONTRACTOR SHALL PROCURE ALL MATERIALS TO BE USED

ON THIS PROJECT IN ORDER TO COMPLETE THE WORK AFTER STARTING IN THE SHORTEST

AMOUNT OF TIME.

CONTRACTOR SHALL INCLUDE IN THEIR WORK ABATEMENT OF THE EXISTING

COMPOSITION TILE FLOOR. THE CONTRACTOR SHALL EMPLOY A COMPANY CERTIFIED TO

ABATE HAZARDOUS MATERIALS FOR THIS WORK.

CONTRACTOR TO ROPE OFF WITH CAUTION TAPE THE WORK AREA WHEN WORK IS NOT

OCCURRING.

NO CONSTRUCTION STORAGE WILL BE PERMITTED INSIDE THE BUILDING. THIS INCLUDES

CONSTRUCTION MATERIALS AND TOOLS. THESE ARE TO BE STORED IN SECURE TRAILER(S)

OUTSIDE OF THE BUILDING.

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781 248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

PL

UR

IB

U

E S

U N U

M

C I

R C

U M

S P

I C

E

S I

Q U

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

A1 OF 1

RELEASED FOR BIDS 11/04/24

OWNER REVIEW 10/21/24

ADMINISTRATION BUILDING

VISITING ROOM - NEW BODY

SCANNER ROOM

NEWBERRY CORRECTIONAL

FACILITY

NEW BODY SCANNER ROOM

FILE NO: 472/19114.ABG

ACCT.NO:472NCFMaintProj

ADMINISTRATION BLDG

SCALE: 1/64" = 1'-0"

CODE DATA:

MICHIGAN REHABILITATION CODE - 2015 - ALTERATIONS LEVEL 2

MICHIGAN MECHANICAL CODE - 2021

MICHIGAN PLUMBING CODE - 2021

NATIONAL ELECTRICAL CODE - 2023

ADMINISTRATION BUILDING AREA = 23,437 gsf AREA OF ALTERATION WORK: 1469 sf

TYPE II-B CONSTRUCTION

OCCUPANCY GROUP B

NO FIRE SUPPRESSION

DOOR ELEVATION

SCALE: 1/2" = 1'-0"A1

AutoCAD SHX Text

13747 COUNTY ROAD 428 NEWBERRY, MI 49868

Sheets and Views
XRay Room

File details come from the government source that posted it. Updated .