18019-0024_OCCD_FDC_ISO_CELL_UNITS_F_&_G__100%CD_.pdf

PDF 23 MB Posted

Attached to
Orange County Corrections Department Female Detention Center Two Cell Renovations and Complete Domestic Water Piping Replacement
Solicitation number
Y25-790-RC
Issued by
Orange County, Orlando City, Florida

About this file

The document is a set of architectural and engineering construction drawings for the Orange County Corrections Department's Female Detention Center Isolation Cell Renovations in Units F and G, located at 3503 Vision Blvd, Orlando, Florida. The project involves converting open group cell units in Quad B, Units F and G, into closed group units with swing doors, including railing modifications, revisions to mechanical, electrical, plumbing, fire protection, and fire alarm systems, addition of two single staff unisex restrooms, and three new exterior maintenance chases. The drawings are dated 05/22/2024 and represent 100% Construction Documents prepared by Rhodes+Brito Architects and C&S Companies, with structural, mechanical, electrical, plumbing, and fire protection engineering components.

The project's design team includes multiple consultants: Rhodes+Brito Architects for architectural services, C&S Companies for structural, fire protection, plumbing, mechanical, and electrical engineering, Fitzgerald Technology Group for technology services, and is being executed for the Orange County Government Capital Projects Division. The construction documents detail comprehensive renovations to existing detention facility infrastructure, including modifications to cell configurations, mechanical systems, electrical systems, and support spaces. The drawings provide extensive technical specifications for demolition, new construction, material selections, system upgrades, and detailed architectural and engineering requirements, ensuring compliance with Florida Building Code, Florida Accessibility Code, and specific corrections facility standards.

View the file

Other files

File Type Posted
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#32_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#25_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#24_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#22_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#18_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#17_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#16_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#15_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#10_Revision).pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement_(Addendum_#5_Revision).pdf PDF
FDC_DW_Replacment_100%_Drawings.pdf PDF
FDC_DW_Replacment_100%_Drawings.pdf PDF
FDC_DW_Replacment_100%_Drawings.pdf PDF
FDC_DW_Replacment_100%_Drawings.pdf PDF
FDC_DW_Replacment_100%_Drawings.pdf PDF
FDC_DW_Replacment_100%_Drawings.pdf PDF
Y25-900-RC_Sign_in_Sheet.pdf PDF
Orange_County_Corrections_Department_Female_Detention_Center_Two_Cell_Renovations_and_Complete_Domestic_Water_Piping_Replacement.pdf PDF
Vol_02_100_2024-05-22.pdf PDF
Vol_01_100_2024-05-22.pdf PDF
Project_Manual.pdf PDF
FDC_DW_Replacment_100%_Drawings.pdf PDF
18019-0024_OCCD_FDC_ISO_CELL_UNITS_F_&_G__100%CD_.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIS PROJECT INCLUDES CONVERTING THE OPEN GROUP

CELL UNITS IN THE FEMALE DETENTION CENTER, QUAD B,

UNITS F & G, INTO CLOSED GROUP UNITS WITH SWING

DOORS. PROJECT SCOPE INCLUDES RAILING

MODIFICATIONS, REVISION OF EXISTING MECHANICAL,

ELECTRICAL, PLUMBING, FIRE PROTECTION AND FIRE

ALARM SYSTEMS, ADDITION OF TWO SINGLE STAFF UNISEX

RESTROOMS, AND THREE NEW EXTERIOR MAINTENANCE

CHASES.

PROJECT DESIGN TEAM

PROJECT SCOPE

RHODES+BRITO ARCHITECTS

605 E. ROBINSON ST, SUITE 750

ORLANDO, FL 32801

PH. (407) 648-7288

CONTACT: DONALD WILLIAMS

ARCHITECTURAL

C&S COMPANIES

605 E. ROBINSON ST, SUITE 210

ORLANDO, FL 32801

PH: (407) 422-1118

CONTACT: ANDREA CELLA

STRUCTURAL

C&S COMPANIES

605 E. ROBINSON ST, SUITE 210

ORLANDO, FL 32801

PH: (407) 422-1118

CONTACT: BRYN CURRIE

FIRE

PROTECTION

C&S COMPANIES

605 E. ROBINSON ST, SUITE 210

ORLANDO, FL 32801

PH: (407) 422-1118

CONTACT: BRYN CURRIE

PLUMBING

C&S COMPANIES

605 E. ROBINSON ST, SUITE 210

ORLANDO, FL 32801

PH: (407) 422-1118

CONTACT: MATTHEW MCQUINN

MECHANICAL

C&S COMPANIES

605 E. ROBINSON ST, SUITE 210

ORLANDO, FL 32801

PH: (407) 422-1118

CONTACT: WILLIAM O'CONNOR

ELECTRICAL

FITZGERALD TECHNOLOGY GROUP

P.O. BOX 907

WINDERMERE, FL 34786

PH: (407) 491-2202

CONTACT: W DOUGLAS FITZGERALD

TECHNOLOGY

VICINITY MAP

PROJECT

LOCATION

A C CT T SEH IR

AA0002809

C&S COMPANIES

605 E. ROBINSON ST, SUITE 210

ORLANDO, FL 32801

PH: (407) 422-1118

CONTACT: WILLIAM O'CONNOR

FIRE ALARM

ORANGE COUNTY CORRECTIONS DEPARTMENT

FDC ISOLATION CELL RENOVATIONS IN UNITS F & G

100% CONSTRUCTION DOCUMENTS

05/22/2024

ORANGE COUNTY GOVERNMENT

CAPITAL PROJECTS DIVISION

400 East South Street, Suite 500 Orlando, FL 32801

3503 Vision Blvd.

Orlando, FL 32839

G000

DATE SUBMISSION / REVISION NO.

SF

r h o d e s + b r i t o A R C H I T E C T S

4" TYP

UNO

0 8 20

100'-0"

FIN FLOOR

A

A101

A2

A711

A2

A711

MATERIALS LEGEND

DRAWING FORMAT

LIST OF ABBREVIATIONS

DIMENSIONING DRAWING SYMBOL LEGEND

(123)

ROOM

NAME

OFFICE

A101

A711A scale:

drawn:

check:

date:

project no:

2001.001

01.01.01 date submission/revision no.

Client Logo and

Project Title

ALL REPRODUCTION

AND INTELLECTUAL

PROPERTY RIGHTS

RESERVED

c

CLIENT LOGO HERE

KEY PLAN HERE

A

B

C

D

E

F

G

H

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

19.02

TYP

TYP

G1

E1

C1

A1 A3

C3

E3

G3

A5 A7 A9

C5

EACH SHEET IS DIVIDED INTO A GRID. AN ALPHA-NUMERIC GRID COORDINATE SYSTEM IS USED TO ORGANIZE THE DRAWING TITLES

DRAWING TITLES ARE NUMBERED ACCORDING TO ITS LOCATION ON THE GRID. THE LOWER LEFT HAND CORNER GRID OF THE

DRAWING IS USED AS THE IDENTIFICATION NUMBER (SEE DIAGRAM).

COLUMN CENTERLINE

PARTITIONS ARE DIMENSIONED TO FACE OF STUDS, FACE OF CMU AND FACE OF

BLOCK UNLESS

INDICATED OTHERWISE

DIMENSIONS ARE INDICATED ON DRAWINGS, DO NOT SCALE DRAWINGS

6.

7.

PARTITION

KEYNOTE REFERENCE

ELEVATION

REFERENCE

REVISION

IDENTIFICATION

PARTITION TYPE

IDENTIFICATION

WINDOW TYPE

REVISION NUMBER

(REFER TO TITLE

BLOCK)

TARGET ELEVATION

TARGET DESCRIPTION

WINDOW DESIGNATION

(REFER TO WINDOW

SCHEDULE)

REFERENCE NUMBER

PARTITION TYPE

(REFER TO PARTITION

TYPE DETAILS)A

GRAPHIC SCALE

ELEVATION

REFERENCE

MULTIPLE INTERIOR H7

S

A5.68 W E

N

INDICATES FEET

DRAWING ON WHICH

ELEVATION OCCURS

MULTIPLE ELEVATION

NUMBER

ELEVATION ORIENTATION

ON PLANS

WHEN A ROOM/BUILDING/OBJECT CENTERLINE IS INDICATED, ONLY ONE SIDE OF

ELEMENT MAY BE

DIMENSIONED

PARTITIONS WITH FINISH FACE FLUSH WITH FINISH FACE OF COLUMN WILL NOT BE

DRAWN ON SMALL

SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE DRAWINGS.

COLUMN CENTERLINE

PARTITION FINISH FACE ON COLUMN OR GRID LINE WILL NOT BE DIMENSIONED ON

SMALL SCALE

PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE DRAWINGS.

PARTITIONS CENTERED ON COLUMNS OR GRID LINES WILL NOT BE DIMENSIONED ON

SMALL SCALE

PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE DRAWINGS.

5.

4.

PARTITION

3.

B. AS DIMENSIONED

COLUMN CENTERLINE

PARTITION

DOOR LOCATION

DOORS ARE LOCATED BY ONE OF THE FOLLOWING:

A. ONE JAMB FACE LOCATED BY A PARTITION AT RIGHT ANGLE.

2.

1.

PARTITION

DOOR

INTERIOR

ELEVATION

REFERENCE

ACCESSORY

IDENTIFICATION

DOOR NUMBER

SPOT

ELEVATION

REFERENCE

TRUE

NORTH

ARROW

DOOR NUMBER

(SEE DOOR SCHEDULE)

TARGET ELEVATION

ACCESSORY TYPE

(REFER TO ACCESSORY

SCHEDULE)A

ELEVATION NUMBER

ELEVATION ORIENTATION

DRAWING ON WHICH

ELEVATION OCCURS

ROOM SPACE IDENTIFICATION NOTATION

BUILDING AREA

WALL SECTION

OR BUILDING

SECTION

REFERENCE

NUMBER

DRAWING ON WHICH

SECTION OCCURS

SECTION ORIENTATION

SECTION NUMBER

ROOM NAME

COLUMN

IDENTIFICATION

B

DETAIL

REFERENCE

A3.11

H6

COLUMN CENTERLINE

DRAWING ON WHICH

DETAIL OCCURS

DETAIL NUMBER

REVISION SYMBOLS

IDENTIFICATION

SPACE

REVISION AREA

REVISION NUMBER

SPACE NAME

SPACE NUMBER

NET ROOM AREA (SF)

DRAWING SHEET NUMBERS

SUBCATEGORY

SHEET NUMBER

ITEM

CATEGORY

DISCIPLINE:

L - Landscape

S - Structural

A - Architectural

P - Plumbing

E - Electrical

M - Mechanical (HVAC)

C - Civil

RIGID INSULATION

POROUS FILL

GYPSUM BOARD /

GROUT FILL

BATT INSULATION

STEEL

PLYWOOD

(OR GLULAM)

CONTINUOUS

ROUGH LUMBER

DISCONTINUOUS

ROUGH LUMBER

CONCRETE MASONRY UNITSFINISH LUMBER

CONCRETE

EARTH

PROJECT

NORTH

ARROW

DRAWING INDEX

BEXISTING COLUMN

INDENTIFICATION

MISCELLANEOUS CHANNEL

MECHANICAL/ELECTRICAL/PLUMBING

LAMINATED VENEER LUMBER

COMPT COMPARTMENT

BW

BVL

BOTH WAYS

BEVELED

BM

BSL

BS

BOT

BRK

BUR

BRG PL

BRG

BSMT

BO

BD

BLDG

BLK(G)

BIT

BET

BEL

BENCH MARK

BUILDING SETBACK LINE

BUILT UP ROOFING

BOTH SIDES

BEARING PLATE

BOTTOM OF

BASEMENT

BRICK

BEARING

BOTTOM

BITUMINOUS

BLOCK(ING)

BUILDING

BOARD

BETWEEN

BELOW

CP

CT

CYD

CORR

CRS

CR

CSMT

CENTER POINT

CUBIC YARD

COURSE(S)

CORRUGATED

CERAMIC TILE

CHROMIUM (PLATED)

CASEMENT

ADDENDUMADD

A/V

AUTO

ASPH

ASB

ARCH

APROX

ANOD

AP

AHU

A/E

ADD'D

ANC

ALUM

ALT

ADJ

ADH

AFF

ANCHOR(AGE)

AUDIO VISUAL

ACCESS PANEL

APPROXIMATE

ARCHITECT(URAL)

ANODIZED

ASBESTOS

ASPHALT

AUTOMATIC

AIR HANDLING UNIT

ARCHITECT/ENGINEER

ADDITIONAL

ABOVE FINISHED FLOOR

ADJUSTABLE

ADHESIVE

ALTERNATE

ALUMINUM

AD

AB

A/C

ACT

ACPL

AC

ACC

ABV

ACOUSTICAL

ACOUSTICAL PLASTER

ACOUSTICAL TILE

AIR CONDITIONING

ANCHOR BOLT

AREA DRAIN

ABOVE

ACCESS

CI CAST IRON

CNTRSNK

CO

CONN

CONT

CONTR

CONST

CONC

COL

CNTR

CLOS

CK

CJ

CMU

CLS

CLR

CIR

CLC

CIP

CONNECTION

COUNTERSINK

CONTRACT(OR)

CONTINUOUS

CONSTRTION

CLEAN OUT

CENTER

CONCRETE

COLUMN

CONTROL JOINT

CAST-IN-PLACE

CONC MASONRY UNIT

CLEAR(ANCE)

CLOSET

CAULK

CEILING

CLOSURE

CIRCLE

CG

C/C

CAT

CFT

CHAM

CHT

CB

CAB

CORNER GUARD

CENTER TO CENTER

CUBIC FOOT

CEILING HEIGHT

CAST BASIN

CATEGORY

CHAMFER

CABINET

MANHOLEMH

INVERTINV

FRP FIBERGLASS REINFORCED

PLASTICEJ EXPANSION JOINT

GALVANIZED STEEL SHEET

EQUIP

EXT

EXP

EX

EST

ESC

EWC

ENGR

EQ

ENCL

EMER

ELEV

EL

EP

ELEC

EQUIPMENT

EXPANDED(EXPANSION)

ELECTRIC WATER COOLER

EXTERIOR

EXISTING

ESTIMATE

ESCALATOR

ELECTRICAL POWERBOARD

ENGINEER

EQUAL

ENCLOSE(URE)

EMERGENCY

ELEVATOR

ELEVATION

ELECTRICAL

GKT GASKET(ED)

GP

GYP

GWB

GYPBD

GLAM

GL

GSS

GYPSUM WALL BOARD

GYPSUM BOARD

GLUE LAMINATED

GALVANIZED PIPE

GYPSUM

GLASS

GA

GI

GEN'L

GD

GB

GC

GALV

FURN

FT

FUT

FUR

FS

FTG

FRT

GALVANIZED IRON

GENERAL CONTRACTOR

GALVANIZED

GAUGE

GENERAL

GRADE

GRAB BAR

FURNITURE/FURNISHINGS

FIRE-RETARDANT

FOOT

FUTURE

FURRING

FULL SIZE

FOOTING

JT

KIT

KO

JC

JB

JF

JST

IPS

JOINT

KITCHEN

KNOCKOUT

JANITOR CLOSET

JUNCTION BOX

JOINT FILLER

IRON PIPE SIZE

JOIST

MIR

MISC

MIN

MTD

MO

MM

MT

MASONRY OPENING

MIRROR

MISCELLANEOUS

MILLIMETER

MINIMUM

METAL THRESHOLD

MOUNTED

FIRE-RESISTANT COATING

FIRE EXTINGUISHER CABINET

FINISHED FLOOR ELEVATION

EXTERIOR INSULATION & FINISH

SYSTEM

DISP DISPENSER

EB

EIFS

E

EA

DWR

DR

DN

DWG

DRB

DS

DIV DR

DTL

DL

DP

EXPANSION BOLT

EAST

EACH

DRAWER

DIVISION DOOR

DAMP PROOFING

DOOR

DOWN

DRAWING

DRAIN BOARD

DOWN SPOUT

DETAIL

DEAD LOAD

DEPT

DBL

DF

DH

DIM

DIA

DEP

DEMO

DRINKING FOUNTAIN

DEMOLISH, DEMOLITION

DEPARTMENT

DOUBLE

DIMENSION

DOUBLE HUNG

DIAGONAL

DEPRESSED

FF FACTORY FINISH

FR

FND

FPL

FRC

FP

FOS

FOF

FOM

FOC

FLUOR

FH

FJT

FLR

FLEX

FLG

FFE

FIN

FGL

FRAME(D)(ING)

FOUNDATION

FLOOR PLATE

FACE OF STUDS

FACE OF FINISH

FACE OF MASONRY

FACE OF CONCRETE

FIREPROOF

FLUORESCENT

FIRE HYDRANT

FLUSH JOINT

FIBERGLASS

FLOOR

FLEXIBLE

FLASHING

FINISH(ED)

FBO

FCO

FEC

FE

FA

FAS

FD

FB

FURNISHED BY OTHERS

FLOOR CLEAN OUT

FIRE EXTINGUISHER

FIRE ALARM

FASTEN, FASTENER

FLOOR DRAIN

FACE BRICK

INSULATED BY CONTRACTOR

HEATING/VENTILATING/AIR

CONDITIONING

HP HIGH POINT

INCL

INT

IBC

INFO

ID

INSUL

HR

HWH

HRDW

HWD

HD HT

HTG

HT

HVAC

HOT

WATER

HEATER

INCLUDE(D)(ING)

INFORMATION

INSIDE DIAMETER

INSULATION

INTERIOR

HARDWOOD

HEAD HEIGHT

HOUR

HARDWARE

HEATING

HEIGHT

HM

HB

HOR

HBD

HJT

HDR

HD

HC

HOLLOW METAL

HORIZONTAL

HARDBOARD

HEAD JOINT

HEAVY DUTY

HOLLOW CORE

HOSE BIBB

HEADER

LUMP SUMLS

MED

MEMB

MECH

MAS

MAT'L

MAX

MEP

MTL

MFR

LVR

LVL

MC

M

LT

MATERIAL

MECHANICAL

MEDIUM

MEMBRANE

MAXIMUM

MANUFACTURER

METAL

MASONRY

LOUVER

METER

LIGHT

LAV

LAM

LBL

LAB

LF

LH

LB

LL

LAVATORY

LAMINATE

LINEAR FOOT

LEFT HAND

LABORATORY

LAG BOLT

LIVE LOAD

LABEL

WROUGHT IRON

VINYL ASBESTOS TILE

WELDED WIRE FABRIC

WALL TO WALL

UNDERWRITERS LABORATORY

UNLESS NOTED OTHERWISE

VAPOR BARRIER

VINYL COMPOSITION TILE

WHEEL BUMPER

WATER REPELLENT

WATERPROOFING

WATER CLOSET

WHB

STANDARDSTD

ROOMRM

PRE CAST CONCRETEPCC

ROUGH OPENING

REVERSE(SIDE)

RIGHT OF WAY

RAIN WATER CONDUCTOR

POLYVINYL CHLORIDE

POUNDS PER CUBIC FOOT

POUNDS PER LINEAL FOOT

POUNDS PER SQUARE FOOT

POINT/PRESSURE TREATED

POUNDS PER SQUARE INCH

PROPERTY LINE/PLATE

PREFABRICATE(D)

PRE FINISHED

PLASTIC LAMINATE

PAIR/PROPOSAL REQUEST

PRELIMINARYPRELIM

PVC

PSF

PT

PSI

PRF

PTN

PVMT

PERFORMED

PARTITION

PAVEMENT

PLF

PLYWD

PREFAB

PNT

PR

POL

PLBG

PNL

PNTD

PLYWOOD

PAINT

POLISHED

PLUMBING

PANEL

PAINTED

PCF

PG

PL

PERIM

PH

PFN

PJ

PLAM

PLAS

PLATE GLASS

PERIMETER

PHASE

PANEL JOINT

PLASTER

RO

ROW

RVS

RWC

TOP OF MASONRY

TONGUE AND GROOVE

TOILET PARTITION

TOILET PAPER DISPENSER

THRES THRESHOLD

TR TRANSOM

TYPICAL

TELEVISION

TYP

TV

TOLERANCE

TOP OF

TOP OF STEEL

TOP OF WALL

TOILET

TOL

TO

TOM

TOS

TOW

TLT

TPTN

TPD

TOWEL BAR

TREAD

THICK(NESS)

TEMPORARY

TERRAZZO

TELEPHONE

TB

T

T&G

THK

TEMP

TER

TEL

SYSTEM

SYNTHETIC

SYMMETRY(ICAL)

SUSPENDED

STRUCTURAL

STORAGE

STEEL

SYS

SYN

SYM

SUS

STR

STOR

STL

WTW

WWF

WI

WSCT

WO

WM

WIN

WTH

WS

WR

WP

WAINSCOT

WITHOUT

WIRED MESH

WINDOW

WIDTH

WATER STOP

RUBBER BASE

REQUEST FOR INFO

ROOF HATCH

REFLECTED CEILING PLAN

REVISION(S),(D)

REFLECT(ED),(ING)

REFRIGERATOR

RAIN LEADER

REINFORCE(D),(ING)

QUARRY TILE

VERTICAL DATUM

NATIONAL GEODETIC

NOT APPLICABLE

NOT IN CONTRACT

OUTSIDE DIAMETER

NOT TO SCALE

OVERFLOW ROOF DRAIN

OPPOSITE HAND

PC

OV

OPP

ORD

OS

PRE CAST

OVERALL

OPPOSITE

OUTSIDE

OC

OFC

OH

OD

OPG

OH/OPH

ON CENTER

OFFICE

OVERHEAD

OPENING

NGVD

N

NA

NIC

NO

NOM

NTS

NORTH

NUMBER

NOMINAL

RADIUSRAD

RFI

RFH

RFG

REV

RES

RET

RH

RFL

RL

ROOFING

RESILIENT

RETURN

RIGHT HAND

REQ'D

RD

RB

RCP

REM

REF

REFR

REG

REINF

REQUIRED

ROOF DRAIN

REMOVE

REFERENCE

REGISTER

RA

R

QTR

QT

RETURN AIR

RISER

QUARTER

SLAB ON GRADE

STAINLESS STEEL

SPECIFICATION(S)

SHELVINGSH

STATION

SQUARE YARD

SQUARE INCH

SQUARE

SPECIAL

SPEAKER

SPACER

STA

SQ/YD

SQ/IN

SS

SQ

SPEC

SPL

SPK

SPCR

SEALER

STEEL JOIST

SHELVING

SOUND PROOF

SLEEVE

SIMILAR

SHEET

SHEATHING

SOG

SLR

SJ

SHELV

SP

SL

SIM

SHT

SHTH

SQUARE FOOT

SOUTH

STORM DRAIN

SOLID CORE

SHEET GLASS

SECTION

SCHEDULE

SAFETY GLASS

SF

S

SD

SC

SG

SECT

SCHED

SFGL

W/

WH

WB

WD

WG

W

WC

WITH

WALL HUNG

WOOD BASE

WOOD

WIRED GLASS

WEST

VAT

VEST

VB

VCT

VAR

VERT

VESTIBULE

VARNISH

VERTICAL

UNF

UR

UL

UNO

UC

UNFINISHED

URINAL

UNDERCUT

OPCI OWNER PROVIDED

CONTRACTOR INSTALLED

OPOI OWNER PROVIDED

OWNER INSTALLED

CPCI CONTRACTOR PROVIDED

CONTRACTOR INSTALLED

RECEP RECEPTIONIST

SECRETARYSECR

SECURITYSECU

AHJ AUTHORITY HAVING JURISDICTION

VOL VOLUME

FV FIELD VERIFIED

ARCHITECTURAL

REV. NO. SHEET NAME

AD101 DEMOLITION PLAN - OVERALL

AD201F DEMOLITION PLAN - LEVEL 1, UNIT F

AD201G DEMOLITION PLAN - LEVEL 1, UNIT G

AD202F DEMOLITION PLAN - LEVEL 2, UNIT F

AD202G DEMOLITION PLAN - LEVEL 2, UNIT G

A101 FLOOR PLAN - OVERALL

A111F FLOOR PLAN - LEVEL 1, UNIT F

A111G FLOOR PLAN - LEVEL 1, UNIT G

A112F FLOOR PLAN - LEVEL 2, UNIT F

A112G FLOOR PLAN - LEVEL 2, UNIT G

A131F REFLECTED CEILING PLAN - LEVEL 1, UNIT F

A131G REFLECTED CEILING PLAN - LEVEL 1, UNIT G

A132F REFLECTED CEILING PLAN - LEVEL 2, UNIT F

A132G REFLECTED CEILING PLAN - LEVEL 2, UNIT G

A141 ROOF PLAN

A201 EXTERIOR ELEVATIONS

A202 EXTERIOR ELEVATIONS

A221 INTERIOR ELEVATIONS

A301 PARTIAL BUILDING SECTIONS

A321 WALL SECTIONS

A401 ENLARGED CHASE PLANS

A402 ENLARGED RESTROOM PLANS AND DETAILS

A403 ENLARGED STAIR PLAN, SECTIONS &

DETAILS

A501 EXTERIOR DETAILS

A601 DOOR SCHEDULE AND DETAILS

A602 STOREFRONT TYPES AND DETAILS

A621 ROOM FINISH SCHEDULE AND DETAILS

A901 3D VIEWS

GENERAL

REV. NO. SHEET NAME

G000 COVER SHEET

G001 GENERAL INFORMATION AND DRAWING

INDEX

G041 WALL TYPES / DETAILS

G101 LIFE SAFETY PLAN - LEVEL 1

G102 LIFE SAFETY PLAN - LEVEL 2

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

NOT FOR CONSTRUCTION

CAPITAL PROJECTS

DIVISION

Consultants

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

225 E. Robinson Street, Suite 145 Orlando, Florida 32801

Phone: 407-422-1118

C&S Engineers, Inc.

FL. L.B. No. 7513 COA No. 7602

12" = 1'-0"

G001

GENERAL

INFORMATION AND

DRAWING INDEX

DW

CM

05/22/2024

18019-0024

04/26/2024

DONALD M. WILLIAMS, AIA

FL REG NO 92126

ORANGE COUNTY

CORRECTIONS

DEPARTMENT

FDC ISOLATION CELL

RENOVATIONS IN UNITS

F & G

3503 Vision Blvd.

Orlando, FL 32839

100% CONSTRUCTION DOCUMENTS

ELECTRICAL

REV. NO. SHEET NAME

E100 SYMBOLS, LEGEND, & GENERAL NOTES

E101 OVERALL FLOOR PLAN

ED111F DEMOLITION PLAN - LEVEL 1, UNIT F

ED111G DEMOLITION PLAN - LEVEL 1, UNIT G

ED112F DEMOLITION PLAN - LEVEL 2, UNIT F

ED112G DEMOLITION PLAN - LEVEL 2, UNIT G

ED113F DEMOLITION PLAN - ROOF, UNIT F

ED113G DEMOLITION PLAN - ROOF, UNIT G

E111F LIGHTING PLAN - LEVL 1, UNIT F

E111G LIGHTING PLAN - LEVL 1, UNIT G

E112F LIGHTING PLAN - LEVEL 2, UNIT F

E112G LIGHTING PLAN - LEVEL 2, UNIT G

E201 EXTERIOR LIGHTING ELEVATIONS

E221F POWER, COMMUNICATION, AND SECURITY

PLAN - LEVEL 1, UNIT F

E221G POWER, COMMUNICATION, AND SECURITY

PLAN - LEVEL 1, UNIT G

E222F POWER, COMMUNICATION, AND SECURITY

PLAN - LEVEL 2, UNIT F

E222G POWER, COMMUNICATION, AND SECURITY

PLAN - LEVEL 2, UNIT G

E223F POWER PLAN - ROOF, UNIT F

E223G POWER PLAN - ROOF, UNIT G

E401 ENLARGED FLOOR PLANS

E501 ONE-LINE DIAGRAM

E502 PANEL SCHEDULES

MECHANICAL

REV. NO. SHEET NAME

M100 LEGEND, ABBREVIATIONS AND GENERAL

NOTES

MD111F DEMOLITION PLAN - LEVEL 1, UNIT F

MD111G DEMOLTION PLAN - LEVEL 1, UNIT G

MD112F DEMOLITION PLAN - LEVEL 2, UNIT F

MD112G DEMOLITION PLAN - LEVEL 2, UNIT G

MD113F DEMOLITION ROOF PLAN - UNIT F

MD113G DEMOLITION ROOF PLAN - UNIT G

M111F FLOOR PLAN - LEVEL 1, UNIT F

M111G FLOOR PLAN - LEVEL 1, UNIT G

M112F FLOOR PLAN - LEVEL 2, UNIT F

M112G FLOOR PLAN - LEVEL 2, UNIT G

M113F ROOF PLAN - UNIT F

M113G ROOF PLAN - UNIT G

M401 HVAC SECTIONS

M501 HVAC DETAILS

M601 SCHEDULES

M701 CONTROLS

PLUMBING

REV. NO. SHEET NAME

P001 GENERAL NOTES AND DETAILS

PD111F LEVEL 1 - UNIT F SANITARY PLUMBING

DEMOLITION

PD111G LEVEL 1 - UNIT G SANITARY PLUMBING

DEMOLITION

PD112F LEVEL 1 - UNIT F DOMESTIC PLUMBING

DEMOLITION

PD112G LEVEL 1 - UNIT G DOMESTIC PLUMBING

DEMOLITION

PD301 PLUMBING DEMOLITION SECTIONS &

ELEVATIONS

P111F LEVEL 1 - UNIT F SANITARY PLUMBING

P111G LEVEL 1 - UNIT G SANITARY PLUMBING

P112F LEVEL 1 - UNIT F DOMESTIC PLUMBING

P112G LEVEL 1 - UNIT G DOMESTIC PLUMBING

P113F LEVEL 2 - UNIT F SANITARY PLUMBING

P113G LEVEL 2 - UNIT G SANITARY PLUMBING

P114F LEVEL 2 - UNIT F DOMESTIC PLUMBING

P114G LEVEL 2 - UNIT G DOMESTIC PLUMBING

P601F LEVEL 1 & 2 - UNIT F SANITARY RISER

P601G LEVEL 1 & 2 - UNIT G SANITARY RISER

P602F LEVEL 1 & 2 - UNIT F DOMESTIC RISER

P602G LEVEL 1 & 2 - UNIT G DOMESTIC RISER

FIRE PROTECTION

REV. NO. SHEET NAME

FP001 GENERAL NOTES AND DETAILS

FPD111 LEVEL 1 - FIRE PROTECTION DEMOLITION

FPD112 LEVEL 2 - FIRE PROTECTION DEMOLITION

FP111 LEVEL 1 - FIRE PROTECTION

FP112 LEVEL 2 - FIRE PROTECTION

FIRE ALARM

REV. NO. SHEET NAME

FA100 LEGEND, ABBREVIATIONS, & GENERAL

NOTES

FAD111F DEMOLITION PLAN - LEVEL 1, UNIT F

FAD111G DEMOLITION PLAN - LEVEL 1, UNIT G

FAD112F DEMOLITION PLAN - LEVEL 2, UNIT F

FAD112G DEMOLITION PLAN - LEVEL 2, UNIT G

FA111F FIRE ALARM PLAN - LEVEL 1, UNIT F

FA111G FIRE ALARM PLAN - LEVEL 1, UNIT G

FA112F FIRE ALARM PLAN - LEVEL 2, UNIT F

FA112G FIRE ALARM PLAN - LEVEL 2, UNIT G

STRUCTURAL

REV. NO. SHEET NAME

S001 GENERAL NOTES

S002 THRESHOLD INSPECTIONS

SD101 OVERALL DEMO FOUNDATION PLAN

SD111 OVERALL MEZZANINE DEMO PLAN

SD111F SLAB DEMOLITION PLAN - UNIT F

SD111G SLAB DEMOLITION PLAN - UNIT G

SD112F MEZZANINE LEVEL DEMOLITION PLAN - UNIT F

SD112G MEZZANINE LEVEL DEMOLITION PLAN - UNIT G

SD121 OVERALL ROOF DEMO PLAN

SD501 DEMO DETAILS

S101 OVERALL SLAB PLAN

S102 OVERALL 2ND FLOOR PLAN

S111F FOUNDATION & 1ST FLOOR SLAB PLAN - UNIT F

S111G FOUNDATION & 1ST FLOOR SLAB PLAN - UNIT G

S112F MEZZANINE FRAMING PLAN - UNIT F

S112G MEZZANINE FRAMING PLAN - UNIT G

S113 OVERALL ROOF FRAMING PLAN

S201 STRUCTURAL ELEVATIONS AND SECTIONS

S301 SECTIONS

S401 ENLARGED PLANS

S501 STRUCTURAL DETAILS

S502 STRUCTURAL DETAILS

DATE SUBMISSION/REVISION NO.

H

KEY I (DIAMOND)

MATERIAL DESCRIPTION

SHAFT WALLS

METAL STUDSS

WALL TYPES (KEY I + KEY II + KEY III + KEY IV + KEY V) =

M MASONRY

C CONCRETE

W WOOD STUDS

X** COMBINATION

E* EXISTING

** PREFIX TO BE ADDED IN

FRONT OF MATERIAL DESCRIPTION

0.6

KEY II (DIAMOND)

MATERIAL WIDTH

5/8" FURRING OR CHANNELS

1/2" FURRING OR CHANNELS0.5

0.7 3/4" FURRING OR CHANNELS

0.8 7/8" FURRING OR CHANNELS

FURRING SIZES

TYPICAL MATERIAL WIDTHS

2 2-1/2" STUDS OR 1-5/8" CMU

1-5/8" STUDS OR CHANNELS1

3 3-5/8" STUDS

4 4" STUDS OR 3-5/8" CMU

6 6" STUDS OR 5-5/8" CMU

8 8" STUDS OR 7-5/8" CMU

10 9-5/8" CMU

12 11-5/8" CMU

K METAL STUD WALL STACKED OVER MASONRY

X (COMBINATION) SPECIAL MATERIAL CODES

METAL STUD + CONCRETE

METAL STUD + CMU0-19

WOOD STUD + CMU

WOOD STUD + CONCRETE

CMU + CONCRETE

USER DEFINED

20-39

40-59

60-79

80-89

90-99

KEY IV (FIRST QUAD)

PRIMARY WALL MODIFER

B TO 6" ABOVE CEILING, UNO

TO UNDERSIDE OF DECKA

C TO UNDERSIDE OF CEILING

D VARIABLE HEIGHT

E INFILL EXISTING OPENING

G-Z USER DEFINED (OTHER THAN

WHAT IS DEFINED ABOVE)

I,O NOT USED

WALL HEIGHTS

N

KEY V (SECOND QUAD)

SECONDARY WALL MODIFER

RESILIENT CHANNELS (W/ GYP BOARD AND

SOUND INSULATION)

INSULATION ( SOUND ATTENUATION)S

L LEAD LINED GYP BOARD ( W/ SOUND INSULATION)

V VAPOR BARRIER

M FOAM-IN-PLACE INSULATION

A-Z USER DEFINED (OTHER THAN WHAT IS

DEFINED ABOVE)

I,O NOT USED

H SAND FILLED

F METAL STUD FURRING, ON TOP OF

BASE WALL ABOVE CEILING

PA PLUMBING CHASE WALL BOTH STUDS TO DECK

PB PLUMBING CHASE WALL 1 STUD TO DECK

DIMENSIONAL THICKNESS OF WALL#

"C" CONCRETE MATERIAL WIDTHS

KI+II+III

KEYIV KEYV

ADDITIONAL

NOTES

EXAMPLE WALL TYPE (S3AS) = S3

A S

3-5/8" FULL HEIGHT, NOT RATED,

INSULATED METAL STUD WALL

R1

KEY III (DIAMOND)

WALL RATING

1 HR RATED

FIRE RATEDR

R2 2 HR RATED

K SMOKE PARTITION

B1 1 HR RATED SMOKE BARRIER

B2 2 HR RATED SMOKE BARRIER

F METAL STUD FURRING

M8

UNDERSIDE OF ROOF/

FLOOR DECK

FLOOR SLAB

FINISH AS

SCHEDULED

8" REINFORCED CMU TO

UNDERSIDE OF DECK,

TYP UNLESS NOTED

OTHERWISE

FINISH AS

SCHEDULED

CEILING AS

SCHEDULED

BASE AS

SCHEDULED

SECURELY ANCHOR TO

DECK, FIRE RESISTIVE

JOINT SYSTEM - UL

DESIGN HW-D-0022 AT

RATED WALL CONDITIONS

TYPE

A-Z

AT "B" HEIGHT PARTITIONS

WHERE WALL DOES NOT

EXTEND TO DECK ABOVE

GROUT FILL TOP COURSE

A-Z

GROUT FILL TOP

(1) COURSES AT

TOP OF WALL,

TYP

PROVIDE

REINFORCING

AS DESCRIBED

IN GENERAL

PARTITION TYPE

NOTES

M

IN

FOAM-IN-PLACE

INSULATION AT M#M"

PARTITIONS SAND FILL

CELLS AT "M#H"

SEAL SMOKE TIGHT AT

"K" & "B" WALL TYPE

CONDITIONS

ADD FOAM-IN-PLACE INSULATION IN CMU CELLS

SMOKE PARTITION, 8"CMU

2 HR RATED PARTITION, 8"CMU

M8

M8K

M8R2

8" CMU, NOT RATED

TYPE DESCRIPTION REF DESIGN

2 HR RATED SMOKE BARRIER, 8"CMUM8B2

UL DESIGN U905

UL DESIGN U905

M8#-M

ACOUSTICALLY SEAL TOP OF WALL TO UNDERSIDE OF DECKM8#-S

M8-B 8" CMU TO 4" ABOVE CEILING

SAND FILL IN CMU CELLSM8#-H

M8R1 UL DESIGN U9051 HR RATED PARTITION, 8"CMU

M8R#

A-ZA-Z

M8K

A-ZA-Z

1 HR RATED SMOKE BARRIER, 8"CMUM8B1 UL DESIGN U905

M8B#

A-ZA-Z SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

NOT FOR CONSTRUCTION

CAPITAL PROJECTS

DIVISION

Consultants

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

225 E. Robinson Street, Suite 145 Orlando, Florida 32801

Phone: 407-422-1118

C&S Engineers, Inc.

FL. L.B. No. 7513 COA No. 7602

1" = 1'-0"

G041

WALL TYPES / DETAILS

DW

CM

05/22/2024

18019-0024

04/26/2024

DONALD M. WILLIAMS, AIA

FL REG NO 92126

ORANGE COUNTY

CORRECTIONS

DEPARTMENT

FDC ISOLATION CELL

RENOVATIONS IN UNITS

F & G

3503 Vision Blvd.

Orlando, FL 32839

100% CONSTRUCTION DOCUMENTS

GENERAL NOTE: INFORMATION

ON THIS SHEET IS FOR

REFERENCE ONLY, GENERAL

CONTRACTOR SHALL COMPLY

AND COORDINATE WITH THE

LATEST UL DESIGNS

GENERAL NOTES - WALL TYPES

1 REFER TO PLANS FOR LOCATION AND EXTENTS OF RATED WALLS. THE

CONSTRUCTION OF ALL RATED WALLS SHALL CONFORM TO THE REFERENCED

UNDERWRITERS LABORATORIES, INC (UL) OR GYPSUM ASSOCIATION (GA) TEST

ASSEMBLY NUMBERS INDICATED. THE REFERENCED UL OR GA TEST ASSEMBLY

MAY CONTAIN PROPRIETARY PRODUCTS AND/OR MATERIALS WHICH MUST BE

FURNISHED.

2 PROVIDE THROUGH-PENETRATION FIRESTOP SYSTEMS (REFER DIV 7) AND

THROUGH-PENETRATION FIRESTOP DEVICES (REFER DIV 7), SEALANTS AND

RELATED PRODUCTS FOR FIRE-RATED FLOOR AND WALL PENETRATIONS (AND

SEALING TOP OF RATED WALLS TO DECK). THIS WORK ALSO INCLUDES

FIRESTOPPING AT PENETRATIONS THROUGH ALL FIRE-RATED WALLS AND

FLOORS. ALL RATED WALL PENETRATIONS SHALL MAINTAIN THE INTEGRITY OF

THE WALL ASSEMBLY. PROVIDE FIRESTOP SEALANT BETWEEN CMU AND STUD

WALL CONSTRUCTION AT ALL FIRE RATED / SMOKE TIGHT RATED WALLS.

3 THE FOLLOWING STATEMENT: " FIRE AND/OR SMOKE BARRIER—PROTECT ALL

OPENINGS", SHALL BE PLACED ABOVE CEILING HEIGHT AND IN CONCEALED

LOCATIONS STENCILED ON ALL FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS,

SMOKE BARRIERS, AND SMOKE PARTITIONS, OR ANY OTHER WALL REQUIRED TO

HAVE PROTECTED OPENINGS OR PENETRATIONS. STENCILING SHALL USE 3"

HIGH LETTERING WITH A MINIMUM OF 3/8 INCH STROKE IN CONTRASTING COLOR

INCORPORATING THE STENCILED STATEMENT. SUCH LETTERING SHALL BE

LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT

EXEEDING 30 FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION

AND AT EACH CHANGE IN WALL OR PARTITION PLACEMENT.

4 AT EXISTING WALLS SCHEDULED AS SMOKE OR FIRE RATED WALLS, PATCH/INFILL

EXISTING OPENINGS CAUSED BY REMOVED HVAC DUCTS, PIPES, ETC AS

REQUIRED TO ACHIEVE COMPLETE FIRE RATED ASSEMBLY OR SMOKE WALL.

REFER TO WALL DETAIL SHEETS AND UL DETAILS FOR PATCHING AND INFILLING.

5 AT CERAMIC TILE INSTALLATIONS AT SHOWERS AND OTHER AREAS EXPOSED TO

DIRECT WATER SHALL RECEIVE WATERPROOFING MEMBRANE OVER

CEMENTITOUS TILE BACKER BOARD.

6 PARTITIONS AND WALLS AT ALL RESTROOM, AND WET AREAS NOT EXPOSED TO

DIRECT WATER SHALL RECEIVE MOISTURE RESISTANT BOARD. PARTITIONS AND

WALLS AT AREAS AT UNCONDITIONED AREAS OR AREAS WITHOUT HUMIDITY

CONTROL SHALL RECEIVE EXTERIOR SHEATHING IN LIEU OF GYP BOARD

SCHEDULED AT THE PARTITION.

7 SEE INTERIOR ELEVATIONS AND REFLECTED CEILING PLANS FOR HEIGHTS,

QUANTITY AND TYPE OF ALL FINISHES LOCATED ON PARTITIONS AND WALLS.

8 AT ALL WALLS, INCLUDING NON-RATED, ACOUSTICAL, FIRE RATED AND SMOKE

PARTITIONS, ELECTRICAL OUTLETS AND OTHER SERVICE PENETRATIONS AND

OPENINGS IN OPPOSITE SIDES OF THE PARTITION SHALL BE SEPARATED BY TWO

COMPLETE STUD SPACES ACROSS LENGTH OF WALL. SHOULD CONDITIONS BE

PRESENT WHERE THIS DISTANCE IS LESS THAN 24", PROVIDE WALL OPENING

PROTECTIVE MATERIALS (CLIV) AS DESCRIBED IN THE UL BXUV DIRECTORY

ACCORDING TO THE REQUIREMENTS OF THEIR CLASSIFICATION.

9 GYPSUM BOARD TO BE INSTALLED A MINIMUM OF 1/2" ABOVE THE FLOOR SLAB.

REMOVE AND REPLACE EXISTING WATER AND MOISTURE DAMAGED GYPSUM

BOARD WHERE IT OCCURS.

10 LIGHT GAUGE METAL STUD MFR / FABRICATOR SHALL PROVIDE SIGNED AND

SEALED ENGINEERED SHOP DRAWINGS FOR THE DESIGN OF BRACING,

ANCHORAGE, FASTENERS, LAYOUT AND OTHER RELATED WORK FOR COLD

FORMED, LIGHT GAUGE METAL STUD, SHAFTWALL PARTITIONS, CEILINGS, AND

OTHER RELATED FABRICATIONS. DESIGN OF COLD FORMED METAL FRAMING

SHALL CONFORM TO THE LATEST EDITION OF "SPECIFICATION FOR THE DESIGN

OF COLD-FORMED STRUCTURAL STEEL MEMBERS" (AISI). DESIGN OF

NONSTRUCTURAL STEEL FRAMING SHALL CONFORM TO THE LATEST EDITION OF

"STANDARD SPECIFICATION OF NONSTRUCTURAL STEEL FRAMING MEMBERS"

(ASTM).

11 CONTRACTOR SHALL REFER TO AND COORDINATE WALL TYPE PARTITIONS WITH

EXTERIOR ELEVATIONS, WALL SECTIONS, EXTERIRO DETAILS AND STRUCTURAL

DRAWINGS FOR EXTERIOR WALL DETAILING, FINISHES AND REINFORCING.

12 WHERE ABUSE RESISTANT GYP BOARD IS REQUIRED, INSTALL SHEETS FROM

FLOOR LEVEL TO 8 FEET ABOVE FLOOR. THE REMAINING HEIGHT OF WALL SHALL

BE STANDARD GYP BOARD WITH MATCHING THICKNESS AND/ OR RATING (AS

APPLICABLE). AREAS UTILIZING ABUSE RESISTANT GYP BOARD SHALL INCLUDE

BUT IS NOT LIMITED TO SERVICE AREAS, PUBLIC LOBBY, KITCHEN, VENDING,

CUSTODIAL, AND HIGH TRAFFIC CORRIDORS.

13 FOR REINFORCEMENT OF CMU WALLS REFER TO STRUCTURAL DRAWINGS. THIS

IS TO INCLUDE BUT LIMITED TO VERTICAL CELL REINFORCING, CONCRETE TIE

BEAMS, GROUT FILLED BOND BEAMS AND BRACING OF WALLS TO STRUCTURE

ABOVE.

14 FOR WALL ANCHORAGE TO STRUCTURE REFER TO STRUCTURAL DRAWINGS.

15 REFER TO LIFE SAFETY PLANS FOR LOCATION AND EXTENTS OF RATED WALLS.

16 WHEN A PARTITION TYPE THAT HAS MULTIPLE LAYERS OF GYPSUM BOARD IS TO

ALIGN WITH ANOTHER PARTITION TYPE WITH (1) LAYER OF GYPSUM BOARD,

ADJUST WALL TO ENSURE THAT THE OTHER GYPSUM BOARD LAYER(S) WILL BE

FLUSH WITH ADJACENT PARTITION TYPE.

WALL MOUNTED

FIRE EXTINGUISHER

CLASS: 2A: 10B: C

OCCUPANT LOAD USING EXIT

REQUIRED EXIT WIDTH (INCHES)

[OCCUPANT LOAD x 0.2"' per OCCUPANT]

PROVIDED EXIT WIDTH (INCHES)

FE

MAXIMUM TRAVEL DISTANCE TO AN

EXIT

DEAD END

CORRIDOR

SEMI-RECESSED

AUTOMATED EXTERNAL DEFIBRILLATOR

AED

XXX SF

XXX

ROOM AREA (SQUARE FEET)

OCCUPANT LOAD FACTOR

NUMBER OF OCCUPANTS

LIFE SAFETY LEGEND

EXIT SIGN

EXIT SIGN WITH DIRECTIONAL ARROW

XXX

PERSONS

REQUIRED

PROVIDED

XX

XX"

XX"

EXISTING FIRE

RATED WALL

APPLICABLE CODES

1. FLORIDA BUILDING CODE (FBC) 2023 EIGHTH EDITION

2. FLORIDA ACCESSIBILITY CODE 2023 EIGHTH EDITIONN

3. FLORIDA PLUMBING CODE 2023 EIGHTH EDITION

4. FLORIDA MECHANICAL CODE 2023 EIGHTH EDITION

5. FLORIDA FIRE PREVENTION CODE (FFPC) 2023 EIGHTH EDITION

OTHER APPLICABLE CODE CRITERIA, BUT NOT LIMITED TO THE FOLLOWING:

1. NFPA 1, "UNIFORM FIRE CODE," 2024 ED. AS MODIFIED BY FFPC

2. NFPA 10, "STANDARD FOR PORTABLE FIRE EXTINGUISHERS," 2022 EDITION

3. NFPA 13, "STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS," 2022

EDITION

4. NFPA 70, "NATIONAL ELECTRICAL CODE," 2023 EDITION

5. NFPA 72, "NATIONAL FIRE ALARM CODE," 2022 EDITION

6. NFPA 80, "STANDARD FOR FIRE DOORS AND FIRE WINDOWS," 2022 EDITION

7. NFPA 101, " LIFE SAFETY CODE," (LSC) 2024 ED., AS MODIFIED BY THE FFPC

8. NFPA 110, " STANDARD ON EMERGENCY AND STANDBY POWER SYSTEMS, 2022

EDITION.

9. FLORIDA CORRECTIONS ACCREDITATION COMMISSION STANDARDS, EDITION 4.11

10. FLORIDA MODEL JAIL STANDARDS

11. CLASSIFICATION OF WORK: ALTERATION LEVEL 3 PER FBC EIGHTH EDITION 2023

EXISTING BUILDING CHAPTER 6 SECTION 604

CONSTRUCTION CLASSIFICATION

1. OCCUPANCY CLASSIFICATION

1.1 CONSTRUCTION TYPE

1.2 ALLOWABLE HEIGHT

1.3 ALLOWABLE AREA

1.4 ALLOWABLE STORIES

INSTITUTIONAL I--3

II-B

NO CHANGES

NO CHANGES

NO CHANGES

2. EXISTING BUILDING CONSTRUCTION TYPE II-B

3. CONSTRUCTION AREA

3.1 BUILDING B, UNIT G - LEVEL 1

3.2 BUILDING B, UNIT G - LEVEL 2

3.3 STAFF RESTROOM

3.4 RENOVATION AREA - TOTAL

4,230 SF

1,752 SF

59 SF

6,041 SF

PROVIDEDREQUIRED

PLUMBING

MEANS OF EGRESS

1. MAXIMUM TRAVEL DISTANCE

TO AN EXIT

4. MINIMUM NUMBER OF EXITS

(INSTITUTIONAL I-3) =

200 FT, SPRNK

SEE LIFE

SAFETY PLAN

PER TABLE 403.1 / FBC 2020: PLUMBING

CHAPTER 10 - FBC 2020

(PER TABLE 1017.2 FBC 2020 -

EXIT ACCESS TRAVEL DISTANCE)

2. MAXIMUM COMMON PATH OF

TRAVEL

(PER TABLE 1006.2.1 FBC 2020 -

COMMON PATH OF EGRESS TRAVEL)

(PER SECTION 1006.3

EXIT OR EXIT ACCESS DOORWAYS

REQUIRED)

SEE LIFE

SAFETY PLAN

SEE LIFE

SAFETY PLAN

50 FEET

3. MAXIMUM DEAD END

CORRIDOR

(PER SECTION 1020.4 DEAD ENDS)

4. EXISTING NUMBER OF STORIES 2 STORIES

1.4 TOTAL OCCUPANT LOAD - UNIT G

1. OCCUPANT LOAD - BUILDING B, UNIT G

1.1 SLEEPING AREAS (1,973 SF/40)

OCCUPANT LOAD PER TABLE 1004.5 / FBC 2020

1.2 DAYROOM (2,907 SF/35)

1.3 STORAGE/UTILITY

(INSTITUTIONAL I-3) =

100 FT, SPRNK

5. EGRESS EXIT DOORS: MINUMUM 32 INCHES CLEAR WIDTH (NFPA 101_7.2.1.2.3.2)

6. FORCE TO OPEN, APPLIED AT THE LATCH STILE (FBC 1010.1.3/NFPA 101_ 7.2.1.4.5)

6.1. LESS THAN OR EQUAL TO 15 LBF TO OPERATE THE LATCH

6.2. LESS THAN OR EQUAL TO 30 LBF TO SET THE DOOR IN MOTION

6.3. LESS THAN OR EQUAL TO 15 LBF TO FULLY OPEN DOOR TO MINIMUN

REQUIRED WITDH

6.4. LESS THAN OR EQUAL TO 5 LBF FOR INTERIOR SIDE-HINGED OR PIVOTED

SWINGING DOORS WITHOUT CLOSERS

7. EXIT SIGNS: EXIT SIGNS ARE NOT REQUIRED IN DAYROOMS, SLEEPING ROOMS

OR DORMITORIES IN OCCUPANCIES IN GROUP I-3.

8. MEANS OF EGRESS SIZING:

OCCUPANTS x (0.2) FOR DOOR CLEAR OPENING WIDTH (FBC 1005.3.2) OCCUPANTS x (0.3) FOR STAIRWAYS WIDTH CAPACITY IN INCHES PER

OCCUPANT (FBC 1005.3.1)

SERVICE SINK

MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES

WATER CLOSETS

LAVATORIES

DRINKING FOUNTAIN

LEVEL 1 + LEVEL 2,

QUAD B - UNITS F & G: REQUIRED

1 PER CELL

1 PER CELL

PROVIDED

1 PER 100 20*

SEE LIFE

SAFETY PLAN

SHOWERS 1 PER 15 12

URINALS N/A ---

96 BEDS

N/A

SPECIFIED UNIT OF FLOOR SPACE (CHAPTER 16 - PHYSICAL PLANT):

1. MULTIPLE OCCUPANCY CELLS SHALL CONTAIN A MINIMUM OF 40 SQUARE FEET

OF FLOOR SPACE PER INMATE IN THE SLEEPING AREA

2. DAY ROOMS SHALL CONTAIN A MINIMUM OF 35 SQUARE FEET PER INMATE FOR

ALL CELL AREAS, EXCEPT DISCIPLINARY AND ADMINISTRATIVE CONFINEMENT.

FLORIDA MODEL JAIL STANDARDS

* PROPOSED COMBINATION TOILET/LAVATORY UNIT WITH

BUBBLER OPTION IN EACH CELL TO SATISFY DRINKING FOUNTAIN

REQUIREMENT

2876 SF

DAYROOM

221 SF

CELL

65 SF

STORAGE

29 SF

JANITOR

45 SF

CHASE

163 SF

CELL

163 SF

CELL

46 SF

CHASE

221 SF

CELL

61'-4" TRAVEL

DISTANCE THROUGH

COMMON ROOM

PERSONS

REQUIRED

PROVIDED

32"

27"

PERSONS

REQUIRED

PROVIDED

32"

27"

PERSONS

REQUIRED

PROVIDED

32"

27"

CONTINUATION

FROM G102

CONTINUATION

FROM G102

TRAVEL DISTANCE FROM

THIS POINT TO COMMON

PATH OF TRAVEL: 66'-0"

F G

E H

B C

A D

AREA

A

AREA

B

AREA

C

AREA

D

220 SF

CELL

65 SF

STORAGE

29 SF

JANITOR

163 SF

CELL

163 SF

CELL

187 SF

CELL

28 SF

CHASE

45 SF

CHASE

CONTINUATION

FROM G102

CONTINUATION

FROM G102

57' - 0" TRAVEL

DISTANCE

THROUGH

COMMON ROOM

MECHANICAL

B108

DAYROOM

(NIC)

B105

OUTDOOR

RECREATION

(NIC)

B119

OUTDOOR

RECREATION

(NIC)

B139

INDOOR

ACTIVITY

(NIC)

B104

ELECTRICAL

C175

PLUMBING

C174

CORRIDOR

C155

VEHICLE

SALLYPORT

C198

SALLYPORT

YARD

C190

LOBBY

C100

MAIN

CONTROL

ROOM

C104

CORRIDOR

C165

CORRIDOR

C169

OFFICE

C170

DAYROOM

B101

STORAGE

C172

CORRIDOR

B100

OFFICE (NIC)

B106

STAFF

RESTROOM

B107

CELL

B128

FEFEFE

FE FE FE FE

FEFEFE

INDIVIDUAL

SHOWER

B127A

INDIVIDUAL

SHOWER

B137A

ELECTRICAL

C155

STAFF

RESTROOM

A107

2877 SF

DAYROOM

SHOWERS

B127

SHOWERS

B137

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

NOT FOR CONSTRUCTION

CAPITAL PROJECTS

DIVISION

Consultants

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

225 E. Robinson Street, Suite 145 Orlando, Florida 32801

Phone: 407-422-1118

C&S Engineers, Inc.

FL. L.B. No. 7513 COA No. 7602

As indicated

G101

LIFE SAFETY PLAN -

LEVEL 1

DW

CM

05/22/2024

18019-0024

04/26/2024

DONALD M. WILLIAMS, AIA

FL REG NO 92126

ORANGE COUNTY

CORRECTIONS

DEPARTMENT

FDC ISOLATION CELL

RENOVATIONS IN UNITS

F & G

3503 Vision Blvd.

Orlando, FL 32839

100% CONSTRUCTION DOCUMENTS

SCALE: 1/16" = 1'-0"G101

A1 LIFE SAFETY PLAN - LEVEL 1

OPEN

TO

OPEN

TO

BELOW

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

OPEN

TO

BELOW

DN

APPLICABLE CODES

1. FLORIDA BUILDING CODE (FBC) 2023 EIGHTH EDITION

2. FLORIDA ACCESSIBILITY CODE 2023 EIGHTH EDITIONN

3. FLORIDA PLUMBING CODE 2023 EIGHTH EDITION

4. FLORIDA MECHANICAL CODE 2023 EIGHTH EDITION

5. FLORIDA FIRE PREVENTION CODE (FFPC) 2023 EIGHTH EDITION

OTHER APPLICABLE CODE CRITERIA, BUT NOT LIMITED TO THE FOLLOWING:

1. NFPA 1, "UNIFORM FIRE CODE," 2024 ED. AS MODIFIED BY FFPC

2. NFPA 10, "STANDARD FOR PORTABLE FIRE EXTINGUISHERS," 2022 EDITION

3. NFPA 13, "STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS," 2022

EDITION

4. NFPA 70, "NATIONAL ELECTRICAL CODE," 2023 EDITION

5. NFPA 72, "NATIONAL FIRE ALARM CODE," 2022 EDITION

6. NFPA 80, "STANDARD FOR FIRE DOORS AND FIRE WINDOWS," 2022 EDITION

7. NFPA 101, " LIFE SAFETY CODE," (LSC) 2024 ED., AS MODIFIED BY THE FFPC

8. NFPA 110, " STANDARD ON EMERGENCY AND STANDBY POWER SYSTEMS, 2022

EDITION.

9. FLORIDA CORRECTIONS ACCREDITATION COMMISSION STANDARDS, EDITION 4.11

10. FLORIDA MODEL JAIL STANDARDS

11. CLASSIFICATION OF WORK: ALTERATION LEVEL 3 PER FBC EIGHTH EDITION 2023

EXISTING BUILDING CHAPTER 6 SECTION 604

CONSTRUCTION CLASSIFICATION

1. OCCUPANCY CLASSIFICATION

1.1 CONSTRUCTION TYPE

1.2 ALLOWABLE HEIGHT

1.3 ALLOWABLE AREA

1.4 ALLOWABLE STORIES

INSTITUTIONAL I--3

II-B

NO CHANGES

NO CHANGES

NO CHANGES

2. EXISTING BUILDING CONSTRUCTION TYPE II-B

3. CONSTRUCTION AREA

3.1 BUILDING B, UNIT G - LEVEL 1

3.2 BUILDING B, UNIT G - LEVEL 2

3.3 STAFF RESTROOM

3.4 RENOVATION AREA - TOTAL

4,230 SF

1,752 SF

59 SF

6,041 SF

PROVIDEDREQUIRED

PLUMBING

MEANS OF EGRESS

1. MAXIMUM TRAVEL DISTANCE

TO AN EXIT

4. MINIMUM NUMBER OF EXITS

(INSTITUTIONAL I-3) =

200 FT, SPRNK

SEE LIFE

SAFETY PLAN

PER TABLE 403.1 / FBC 2020: PLUMBING

CHAPTER 10 - FBC 2020

(PER TABLE 1017.2 FBC 2020 -

EXIT ACCESS TRAVEL DISTANCE)

2. MAXIMUM COMMON PATH OF

TRAVEL

(PER TABLE 1006.2.1 FBC 2020 -

COMMON PATH OF EGRESS TRAVEL)

(PER SECTION 1006.3

EXIT OR EXIT ACCESS DOORWAYS

REQUIRED)

SEE LIFE

SAFETY PLAN

SEE LIFE

SAFETY PLAN

50 FEET

3. MAXIMUM DEAD END

CORRIDOR

(PER SECTION 1020.4 DEAD ENDS)

4. EXISTING NUMBER OF STORIES 2 STORIES

1.4 TOTAL OCCUPANT LOAD - UNIT G

1. OCCUPANT LOAD - BUILDING B, UNIT G

1.1 SLEEPING AREAS (1,973 SF/40)

OCCUPANT LOAD PER TABLE 1004.5 / FBC 2020

1.2 DAYROOM (2,907 SF/35)

1.3 STORAGE/UTILITY

(INSTITUTIONAL I-3) =

100 FT, SPRNK

5. EGRESS EXIT DOORS: MINUMUM 32 INCHES CLEAR WIDTH (NFPA 101_7.2.1.2.3.2)

6. FORCE TO OPEN, APPLIED AT THE LATCH STILE (FBC 1010.1.3/NFPA 101_ 7.2.1.4.5)

6.1. LESS THAN OR EQUAL TO 15 LBF TO OPERATE THE LATCH

6.2. LESS THAN OR EQUAL TO 30 LBF TO SET THE DOOR IN MOTION

6.3. LESS THAN OR EQUAL TO 15 LBF TO FULLY OPEN DOOR TO MINIMUN

REQUIRED WITDH

6.4. LESS THAN OR EQUAL TO 5 LBF FOR INTERIOR SIDE-HINGED OR PIVOTED

SWINGING DOORS WITHOUT CLOSERS

7. EXIT SIGNS: EXIT SIGNS ARE NOT REQUIRED IN DAYROOMS, SLEEPING ROOMS

OR DORMITORIES IN OCCUPANCIES IN GROUP I-3.

8. MEANS OF EGRESS SIZING:

OCCUPANTS x (0.2) FOR DOOR CLEAR OPENING WIDTH (FBC 1005.3.2) OCCUPANTS x (0.3) FOR STAIRWAYS WIDTH CAPACITY IN INCHES PER

OCCUPANT (FBC 1005.3.1)

SERVICE SINK

MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES

WATER CLOSETS

LAVATORIES

DRINKING FOUNTAIN

LEVEL 1 + LEVEL 2,

QUAD B - UNITS F & G: REQUIRED

1 PER CELL

1 PER CELL

PROVIDED

1 PER 100 20*

SEE LIFE

SAFETY PLAN

SHOWERS 1 PER 15 12

URINALS N/A ---

96 BEDS

N/A

SPECIFIED UNIT OF FLOOR SPACE (CHAPTER 16 - PHYSICAL PLANT):

1. MULTIPLE OCCUPANCY CELLS SHALL CONTAIN A MINIMUM OF 40 SQUARE FEET

OF FLOOR SPACE PER INMATE IN THE SLEEPING AREA

2. DAY ROOMS SHALL CONTAIN A MINIMUM OF 35 SQUARE FEET PER INMATE FOR

ALL CELL AREAS, EXCEPT DISCIPLINARY AND ADMINISTRATIVE CONFINEMENT.

FLORIDA MODEL JAIL STANDARDS

* PROPOSED COMBINATION TOILET/LAVATORY UNIT WITH

BUBBLER OPTION IN EACH CELL TO SATISFY DRINKING FOUNTAIN

REQUIREMENT

219 SF

CELL

151 SF

CELL

169 SF

CELL

171 SF

CELL

149 SF

CELL

221 SF

CELL

CONTINUED

ON G101

CONTINUED

ON G101

TRAVEL DISTANCE FROM THIS

POINT TO AN EXIT: 187'-7"

TRAVEL DISTANCE FROM THIS

POINT TO AN EXIT: 175' - 4"

F G

E H

B C

A D

AREA

A

AREA

B

AREA

C

AREA

D

220 SF

CELL

150 SF

CELL

170 SF

CELL

171 SF

CELL

149 SF

CELL

187 SF

CELL

28 SF

CHASE

CONTINUED

ON G101

CONTINUED

ON G101

FE

MECHANICAL

B208

CHASE

B228A

DAYROOM

B205

OFFICE

B206

STORAGE

B207

MECHANICAL

B204

DAYROOM

B201

OFFICE

B202

STORAGE

B203

WALL MOUNTED

FIRE EXTINGUISHER

CLASS: 2A: 10B: C

OCCUPANT LOAD USING EXIT

REQUIRED EXIT WIDTH (INCHES)

[OCCUPANT LOAD x 0.2"' per OCCUPANT]

PROVIDED EXIT WIDTH (INCHES)

FE

MAXIMUM TRAVEL DISTANCE TO AN

EXIT

DEAD END

CORRIDOR

SEMI-RECESSED

AUTOMATED EXTERNAL DEFIBRILLATOR

AED

XXX SF

XXX

ROOM AREA (SQUARE FEET)

OCCUPANT LOAD FACTOR

NUMBER OF OCCUPANTS

LIFE SAFETY LEGEND

EXIT SIGN

EXIT SIGN WITH DIRECTIONAL ARROW

XXX

PERSONS

REQUIRED

PROVIDED

XX

XX"

XX"

EXISTING FIRE

RATED WALL

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

NOT FOR CONSTRUCTION

CAPITAL PROJECTS

DIVISION

Consultants

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

225 E. Robinson Street, Suite 145 Orlando, Florida 32801

Phone: 407-422-1118

C&S Engineers, Inc.

FL. L.B. No. 7513 COA No. 7602

As indicated

G102

LIFE SAFETY PLAN -

LEVEL 2

DW

CM

05/22/2024

18019-0024

04/26/2024

DONALD M. WILLIAMS, AIA

FL REG NO 92126

ORANGE COUNTY

CORRECTIONS

DEPARTMENT

FDC ISOLATION CELL

RENOVATIONS IN UNITS

F & G

3503 Vision Blvd.

Orlando, FL 32839

100% CONSTRUCTION DOCUMENTS

SCALE: 1/16" = 1'-0"G102

A1 LIFE SAFETY PLAN - LEVEL 2

SCALE:

DATE:

DRAWN BY:

CHECK BY:

PROJECT NUMBER:

1 2 3 4 5 6 7 8 9 10

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

ALL REPRODUCTION AND INTELLECTUAL

PROPERTY RIGHTS RESERVED ©

Seal

NOT FOR CONSTRUCTION

CAPITAL PROJECTS

DIVISION

Consultants

A C CT T SEH IR

605 E. ROBINSON STREET, SUITE 750

ORLANDO, FL 32801

AA0002809

www.rbarchitects.com 407.648.7288

605 E. Robinson Street, Suite 210 Orlando, Florida 32801

Phone: 407-422-1118

C&S Engineers, Inc.

FL. L.B. No. 7513 COA No. 7602

R

S001

GENERAL NOTES

A. CELLA

D. PEEL

05/22/2024

18019-0024

ANDREA L. CELLA, PE

77874

ORANGE COUNTY

CORRECTIONS

DEPARTMENT FDC

ISOLATION CELL

RENOVATIONS IN UNITS

F & G

3503 Vision Blvd.

Orlando, FL 32839

100% CONSTRUCTION DOCUMENTS

DATE SUBMISSION/REVISION NO.

GENERAL

THESE GENERAL NOTES SUPPLEMENT THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS. IN CASE OF CONFLICT WITH THE SPECIFICATIONS, CONTACT THE

OWNER’S REPRESENTATIVE PRIOR TO PROCEEDING WITH THE WORK.

THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE SITE AND LOCAL CONDITIONS.

CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL BUILDING CODES, CODES OF APPLICABLE REGULATORY AGENCIES, AND WITH PROJECT

SPECIFICATIONS AND DRAWINGS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL TRADES AND FOR CHECKING ALL DIMENSIONS. REPORT DISCREPANCIES TO THE

OWNER’S REPRESENTATIVE FOR CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK.

THE CONTRACTOR SHALL COMPLY WITH LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY BEARING UPON THE

PERFORMANCE OF THE WORK.

SUBJECT TO THE STRUCTURAL ENGINEER'S ACCEPTANCE, UTILIZE DETAILS FOR SIMILAR CONDITIONS WHEN DETAILS FOR CONSTRUCTION ARE NOT INDICATED FOR A

SPECIFIC CONDITION.

DETAILS INCLUDING “TYPICAL” OR “TYP” IN THE TITLE APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED. TYPICAL DETAILS ARE NOT NOTED AT EACH LOCATION AT WHICH THEY ARE APPLICABLE.

WHERE NOT INDICATED ON THE STRUCTURAL DRAWINGS, SEE THE ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, AND ANY OTHER

DRAWINGS FOR:

ELEVATIONS AND SLOPES,

SIZE, LOCATION AND EXTENT OF CURBS, FLOOR DEPRESSIONS, AND TOPPING SLABS,

SIZE AND LOCATION OF DRAINS, TRENCHES, SLAB OPENINGS, AND WALL OPENINGS,

SIZE, TYPE AND LOCATION OF NON-LOAD BEARING PARTITIONS,

CONCRETE AND STEEL FINISHES,

SIZE AND LOCATION OF SLEEVES AND HANGERS,

ITEMS EMBEDDED IN THE STRUCTURE OR PENETRATING THE STRUCTURE,

CONNECTION OF ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE

PROTECTION OR ANY OTHER ITEMS TO THE STRUCTURE AND CONNECTION OF ITEMS

NOT TYPICALLY DETAILED ON THE STRUCTURAL DRAWINGS,

WATERPROOFING AND DAMP PROOFING,

SITE AND SUBGRADE DRAINAGE SYSTEMS AND DETAILS.

CONNECTIONS OF ALL TRADES TO THE STRUCTURE SHALL BE DESIGNED AND DETAILED BY THE CONTRACTOR. CONNECTIONS TO STRUCTURAL MEMBERS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW. RESPONSIBILITY FOR THE PERFORMANCE OF THE SUPPLIED SYSTEM AND ASSOCIATED CONNECTIONS SHALL REMAIN THAT OF THE CONTRACTOR. ALL CONNECTIONS SHALL BE DESIGNED BY AN ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED.

OPENINGS AND PENETRATIONS THROUGH STRUCTURAL ELEMENTS AND ITEMS EMBEDDED IN STRUCTURAL ELEMENTS THAT ARE NOT INDICATED ON THE STRUCTURAL DRAWINGS SHALL BE REVIEWED BY STRUCTURAL ENGINEER PRIOR TO IMPLEMENTING WORK.

DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONAL INFORMATION.

DO NOT PLACE MATERIALS OR EQUIPMENT ON UNFINISHED FLOORS OR ROOFS IN EXCESS OF 20 PSF NOR ON FINISHED FLOORS OR ROOFS IN EXCESS OF THE

INDICATED DESIGN LIVE LOADS. AVOID IMPACT LOADING.

THE STRUCTURE WAS DESIGNED FOR THE IN-SERVICE CONDITIONS ONLY. THE METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF THE

STRUCTURE AT ALL STAGES OF CONSTRUCTION.

DRAWINGS DO NOT INDICATE TEMPORARY REQUIREMENTS. NEED FOR TEMPORARY SHORING AND BRACING, TEMPORARY DEWATERING, TEMPORARY EARTH RETENTION, TEMPORARY WATER CUTOFF OR OTHER TEMPORARY MEASURES MAY BE INDICATED ON DRAWINGS AT SELECTED AREAS AS SUGGESTIONS FOR THE CONTRACTOR'S CONVENIENCE. THE DRAWINGS DO NOT IDENTIFY ALL AREAS OR CONDITIONS REQUIRING TEMPORARY MEASURES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONFIRM TEMPORARY MEASURES INDICATED ON THE DRAWINGS, IDENTIFY OTHER AREAS OR CONDITIONS REQUIRING TEMPORARY MEASURES, DETERMINE MOST EFFICIENT TEMPORARY SYSTEMS, AND DESIGN AND CONSTRUCT REQUIRED TEMPORARY SYSTEMS. ALL TEMPORARY SYSTEMS SHALL BE

DESIGNED BY A LICENSED ENGINEER IN THE STATE IN WHICH THE PROJECT IS LOCATED.

INFORMATION RELATED TO EXISTING CONDITIONS REPRESENTS KNOWLEDGE BASED UPON INFORMATION PROVIDED BY THE OWNER BUT WITHOUT GUARANTEE OF ACCURACY. REPORT EXISTING CONDITIONS THAT VARY FROM THOSE SHOWN ON THE CONTRACT DOCUMENTS TO THE OWNER’S REPRESENTATIVE. DO NOT DEVIATE FROM THE CONTRACT DOCUMENTS WITHOUT WRITTEN DIRECTION FROM THE OWNER’S REPRESENTATIVE.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING CONSTRUCTION WHILE PERFORMING WORK. THE CONTRACTOR SHALL PROPERLY REINSTATE EXISTING FINISHES, FIREPROOFING OR ITEMS THAT ARE REMOVED OR DAMAGED WHILE PERFORMING WORK.

UNLESS NOTED OTHERWISE, ELEVATIONS ON THE DRAWINGS ARE RELATIVE TO THE ELEVATION OF THE FIRST FLOOR, WHICH IS PROJECT ELEVATION 0'-0".

ELEVATION 0’-0” CORRESPONDS TO U.S.G.S. DATUM 000.00 FEET.

IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE THE SAFETY OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS, TIE-DOWNS, AND/OR SHORING MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER THE COMPLETION OF THE

PROJECT.

THE CONTRACTOR SHALL SUBMIT COMPLETE SHOP DRAWINGS FOR ALL PARTS OF THE WORK INCLUDING DESCRIPTION OF DEMOLITION, TEMPORARY BRACING, CONSTRUCTION METHODS AND SEQUENCING, WHERE APPLICABLE NO PERFORMANCE OF WORK SHALL COMMENCE WITHOUT REVIEW OF THE SHOP DRAWINGS BY

THE ENGINEER.

FABRICATION PRIOR TO THE RECEIPT OF APPROVED SHOP DRAWINGS SHALL BE AT THE CONTRACTOR'S OWN RISK AND THAT INSTALLATION OF ANY WORK PRIOR TO

RECEIPT OF AN APPROVED SHOP DRAWING SHALL BE STRUCTURALLY PROHIBITED.

THIS STRUCTURE IS A THRESHOLD BUILDING AS DEFINED BY THE FLORIDA BUILDING CODE. SEE REQUIRED INSPECTIONS NOTED IN THIS DRAWING SET.

DESIGN CRITERIA

ALL CONSTRUCTION SHALL CONFORM TO THE MORE RESTRICTIVE OF THE FOLLOWING CODES, THE MOST RECENT EDITIONS OF THE STANDARDS ADOPTED BY THE AUTHORITY HAVING JURISDICTION AS REFERENCED THROUGHOUT THE STRUCTURAL GENERAL NOTES, AND THE FOLLOWING DESIGN CRITERIA:

BUILDING CODE: 2023 FLORIDA BUILDING CODE 8TH EDITION AND THE 2023 FLORIDA BUILDING CODE, EXISTING BUILDING

BUILDING RISK CATEGORY: III

DESIGN DEAD LOADS: SELF-WEIGHT OF MATERIALS AND SYSTEMS

DESIGN LIVE LOADS (UNREDUCED):

ROOFS: 20 PSF

FIRST FLOORS: 100 PSF (UNIFORM), 1,000 LB (CONCENTRATED)

SECOND LEVEL CELL BLOCKS: 40 PSF

SECOND LEVEL CLASSROOMS: 40 PSF (UNIFORM), 1,000 LB (CONCENTRATED)

MECHANICAL ROOM: 100 PSF

SECOND LEVEL STAIRS, CORRIDORS AND EXIT WAYS: 100 PSF (UNIFORM), 300 LB (CONCENTRATED)

EXTERIOR CHASE SECOND FLOOR AND STAIRS: 60 PSF

DESIGN WIND LOADS:

LATERAL LOAD RESISTANCE SYSTEM (BUILDING CODE):

BASIC ULTIMATE WIND SPEED: 145 MILES PER HOUR (3-SEC GUST)

BASIC NOMINAL WIND SPEED: 113 MILES PER HOUR (3-SEC GUST)

NOMINAL TORNADO WIND SPEED: 50 MILES PER HOUR FOR EFFECTIVE AREA UP TO 100,000 SQUARE FEET

WIND EXPOSURE: C

INTERNAL PRESSURE COEFFICIENT: +0.18, -0.18

SITE IS NOT IN A WIND BORNE DEBRIS REGION

COMPONENTS AND CLADDING: SEE TYPICAL DETAIL

DESIGN RAIN LOAD DATA:

PRIMARY DRAINAGE SYSTEMS SHALL BE DESIGNED FOR A RAINFALL INTENSITY EQUAL TO OR GREATER THAN THE 60-MIN DURATION/ 100-YEAR RETURN PERIOD

(FREQUENCY) STORM WITH A RAINFALL INTENSITY: “I” = 4.18 IN/HR

RAIN LOAD BASED ON A HYDRAULIC HEAD RAINFALL INTENSITY EQUAL TO OR GREATER THAN THE 15-MIN DURATION/100-YEAR RETURN PERIOD (FREQUENCY)

STORM WITH A RAINFALL INTENSITY: “I” = 7.59 IN/HR

SUBMITTALS

THE GENERAL CONTRACTOR SHALL REVIEW AND STAMP ALL SHOP DRAWINGS BEFORE SUBMITTING FOR REVIEW.

SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND/OR ENGINEER AND HAVE THE ENGINEER'S SHOP DRAWING STAMP AFFIXED

PRIOR TO FABRICATION.

THE CONTRACTOR SHALL PREPARE A LIST AND SCHEDULE OF ALL STRUCTURAL SUBMITTALS PRIOR TO THE CONSTRUCTION KICK-OFF MEETING

FOR REVIEW BY THE STRUCTURAL EOR.

IN ADDITION, CONTRACTOR SHALL SUBMIT THE GEOTECHNICAL ENGINEERING REPORT OF THE OPEN HOLE INSPECTION, PRIOR TO

CONSTRUCTION

THE OMISSION FROM THE SHOP DRAWINGS OF ANY MATERIALS REQUIRED BY THE CONTRACT DOCUMENTS TO BE FURNISHED SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF FURNISHING AND INSTALLING SUCH MATERIALS REGARDLESS OF WHETHER THE SHOP

DRAWINGS HAVE BEEN REVIEWED AND APPROVED.

REFERENCE SPECIFICATIONS FOR REQUIRED SUBMITTALS

DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE PERMIT APPLICATION

AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.

DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.

DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING.

THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE

BUILDING OFFICIAL.

ALL DEFERRED SUBMITTAL ITEMS ARE TO BE DESIGNED BY THE VENDOR AND SHALL BE DESIGNED BY AN ENGINEER LICENSED IN THE STATE IN

WHICH THE PROJECT IS LOCATED.

DEFERRED SUBMITTAL ITEMS INCLUDE:

PRECAST STRUCTURAL CONCRETE

PRECAST ARCHITECTURAL CONCRETE

METAL STAIRS

PIPE AND TUBE RAILINGS

HANGERS AND SUPPORTS FOR FIRE-SUPPRESSION PIPING AND EQUIPMENT

HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

HANGERS AND SUPPORTS FOR PROCESS SYSTEMS

MODIFICATIONS TO EXISTING CONSTRUCTION

THE EXISTING CONSTRUCTION SHOWN ON THESE DRAWINGS IS PROVIDED FOR REFERENCE ONLY. EXISTING CONSTRUCTION SHALL BE VERIFIED IN THE FIELD PRIOR TO

FABRICATION AND ERECTION OF ALL NEW CONSTRUCTION.

ANY EXISTING FINISHES REMOVED OR DAMAGED TO ACCOMPLISH ANY STRUCTURAL MODIFICATIONS SHALL BE REINSTATED AT THE COMPLETION OF MODIFICATION

WORK, TYPICAL UNLESS NOTED OTHERWISE.

ANY STRUCTURAL STEEL OR REINFORCING BARS THAT HAVE BEEN CUT AND GROUND FLUSH WITH A CONCRETE SURFACE SHALL BE FINISHED WITH EPOXY PAINT.

THE FACE OF ALL NEW PERMANENT CONCRETE SURFACES CUT FROM EXISTING CONCRETE SHALL BE CLEANED WITH A HIGH PRESSURE WATER SPRAY. ALLOW SURFACES TO DRY THOROUGHLY. COAT THE CONCRETE SURFACES WITH A BONDING AGENT AND FINISH WITH AN ACCEPTABLE PATCHING COMPOUND. ALL EXPOSED

REINFORCEMENT SHALL BE GROUND FLUSH WITH THE NEW CONCRETE SURFACE.

WHERE EXISTING CONCRETE REINFORCEMENT IS TO BE REUSED IN-PLACE, THE CONCRETE SHALL BE REMOVED IN A MANNER THAT MINIMIZES DAMAGE TO THE REINFORCEMENT. DAMAGED REINFORCEMENT SHALL BE REPLACED BY A METHOD ACCEPTABLE TO THE STRUCTURAL ENGINEER.

WHERE NEW CONCRETE IS TO BE CAST AGAINST EXISTING CONCRETE, THE CONTACT SURFACE SHALL BE ROUGHENED AND CLEANED WITH A HIGH PRESSURE WATER

SPRAY. ALLOW TO DRY THOROUGHLY PRIOR TO APPLICATION OF EPOXY BONDING AGENT.

ANY NEW STRUCTURAL STEEL REINFORCEMENT BEAMS ADJACENT TO NEW SLAB OPENINGS SHALL BE FULLY INSTALLED PRIOR TO ANY CUTTING FOR THE OPENINGS.

PRIOR TO CUTTING OPENINGS IN ENTIRE SLAB SPANS, ALL ADJACENT SPANS SHALL BE SHORED TEMPORARILY OR AS INDICATED.

ANY EXISTING WALL OPENINGS TO BE INFILLED SHALL BE REINFORCED WITH BARS TO MATCH THOSE IN THE ADJACENT EXISTING CONCRETE. DOWELS FOR THOSE BARS

SHALL BE PLACED INTO ADJACENT CONCRETE.

PRIOR TO CUTTING OPENINGS IN EXISTING WALLS, ANY ADJACENT IN-FILL WORK SHALL BE COMPLETED AND THE IN-FILL CONCRETE SHALL HAVE REACHED ITS REQUIRED

28-DAY COMPRESSIVE STRENGTH.

SAWCUTS FOR NEW WALL OPENINGS SHALL NOT EXTEND PAST THE REQUIRED DIMENSIONS FOR THE OPENING. CORE DRILL THE CORNERS AND EXTEND SAW CUTS INTO THE CORED AREAS AND NOT BEYOND IT. CHIP OUT THE REMAINDER AT THE CORNERS TO ACHIEVE A CLEAN 90 DEGREE CORNER.

THE LOCATION AND LENGTH OF ANY NEW STEEL FRAMING SHALL BE COORDINATED WITH THE EXISTING STEEL DECK SLABS AND ROOF DECKS SUCH THAT THE NEW

STRUCTURAL STEEL BEAM CENTERLINES CORRESPOND WITH THE RIBS OF THE STEEL DECK.

THE CONTRACTOR SHALL SUBMIT COORDINATED SHOP DRAWINGS TO THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO CUTTING OR ERECTION OF ANY NEW

STRUCTURAL STEEL.

VERIFY ACCESSILITY TO THE BUILDING AND MAXIMUM WORKABLE MEMBER LENGTHS BEFORE COMMENCING WITH FABRICATION. IF THE NEW STRUCTURAL ELEMENTS CANNOT BE SHIPPED AND INSTALLED AS CONTINUOUS MEMBERS, ANY SPLICES SHALL CONSIST OF COMPLETE PENETRATION WELDING OF THE FLANGES AND PARTIAL PENETRATION WELDING OF THE WEB OF THE NEW BEAM. THE CONTRACTOR SHALL SUBMIT PROPOSED SPLICE DETAILS AND LOCATIONS TO THE STRUCTURAL ENGINEER

FOR REVIEW AND APPROVAL PRIOR TO FABRICATION.

REMOVE ALL LOADS FROM THE SLAB DIRECTLY ABOVE THE AREAS WHERE NEW STEEL BEAMS ARE TO BE INSTALLED. PROVIDE SHORING UNDER EXISTING SLABS AND BEAMS PRIOR TO AND DURING CONSTRUCTION. ALL NEW STRUCTURAL STEEL SHALL BE IN PLACE PRIOR TO THE REMOVAL OF ANY EXISTING SLABS AND/OR SHORING.

PROVIDE NON-SHRINK GROUT AS REQUIRED FOR FULL BEARING OF THE EXISTING SLAB ON THE NEW BEAMS, UNLESS NOTED OTHERWISE.

REMOVE EXISTING FIREPROOFING LOCALLY AND CLEAN AREAS OF EXISTING STEEL TO BE WELDED. INSTALL NEW U.L. APPROVED FIREPROOFING MATERIAL ON ALL NEW STEEL AND ANY AREAS WHERE FIREPROOFING WAS REMOVED OR DAMAGED DURING THE INSTALLATION OF THE WORK. NEW STEEL SHALL HAVE A FIRE RATING TO MATCH THE ADJACENT EXISTING STEEL, TYPICAL UNLESS NOTED OTHERWISE. REFER TO ARCHITECTURAL DOCUMENTS FOR REQUIRED FIRE RATINGS.

SLAB-ON-GRADE PLACEMENT

THE DESIGN OF CONCRETE MIXES, LOCATING OF CONSTRUCTION JOINTS IN SLABS, STAGGERING OF POUR PLACEMENTS, LOCATION OF POUR STRIPS, AND PLACEMENT AND CURING PROCEDURES ARE TO BE PERFORMED BY THE CONTRACTOR IN A MANNER THAT WILL MINIMIZE SHRINKAGE CRACKING OF THE SLABS.

PLACE INTERIOR SLABS ON VAPOR BARRIER (15 MIL. WITH 0.01 PERMS OR LESS, MINIMUM) WITH SOILS PREPARED PER THE GEOTECHNICAL ENGINEER'S

RECOMMENDATIONS.

NO SLAB PANEL MAY BE CONSTRUCTED ADJACENT TO A PANEL THAT HAS BEEN IN PLACE LESS THAN THREE DAYS (72 HOURS).

THE CONTRACTOR SHALL REPAIR ALL…

This is the start of the file's text. The full file is on GovTribe.