18-Drawings.pdf
PDF 31 MB Posted
- Solicitation number
- 26/0067
- Issued by
- Harris County, Texas
About this file
This file comprises architectural and structural drawing sets prepared by Huitt-Zollars, Inc. for the Harris County Flood Control District (HCFCD) regarding the renovation and buildout of the second floor of the MTSC Distribution Center located at 10700 Vine Crest Drive, Houston, Texas 77086. The project, identified as Z100-00-00-X360, involves the expansion and renovation of approximately 15,000 square feet across two floors of an existing facility that functions as a hub for administrative operations, storage, and distribution activities. The structure is classified as Type II-B construction, not sprinklered, with primary occupancy as Business (Group B) and secondary occupancy as Moderate-Hazard Storage (Group S-1). The project documents include 94 total sheets covering general, architectural, structural, mechanical, plumbing, electrical, fire alarm, communications, audiovisual infrastructure, security, and landscape designs. The drawings were issued for bidding on February 27, 2026, with the project reaching bid-ready status on December 9, 2025, following several revision phases including 50% and 95% coordinated design phases completed in June and July 2025, respectively.
The design accommodates a total occupant load of 94 persons distributed across two levels, with Level 1 supporting 31 occupants and Level 2 supporting 63 occupants. Structural design incorporates composite steel deck with concrete slab systems, reinforced concrete elements, and structural steel framing designed to support office, warehouse, and storage functions with live loads ranging from 100 to 200 pounds per square foot depending on space type. The project complies with the 2018 International Building Code with Harris County amendments, 2021 International Existing Building Code, 2021 International Fire Code with Harris County amendments, 2015 International Mechanical and Plumbing Codes adopted by Texas, and the 2014 National Electric Code adopted by Texas. Building height is approximately 32 feet 6 inches to the parapet, with basic design wind speed of 145 miles per hour and ground snow loads of 5 pounds per square foot. The design includes comprehensive MEP systems, accessibility features compliant with ADA and Texas Accessibility Standards, and life safety provisions including multiple exits, fire-rated partitions, and fire suppression and detection systems appropriate for the facility's use classification.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KEY MAP
VICINITY MAP
S:
\R
.1
- D
C nd F lo or
B ui ld ou t P ro je ct
\1
C
AD
D
B
IM
\1 0.
Au to C
AD
\C ov er
S he et
9-
-2
5.
dw g
PCT. 1,2,3,4
H
AR
D
Y TO
LL R
O
AD
10 10
610 610
99 99
MAINTENANCE CONTRACT - Z100-00-00-X360
MTSC DISTRIBUTION CENTER
SECOND FLOOR BUILDOUT
LESLEY BRIONES
TOM S. RAMSEY, P.E.
ADRIAN GARCIA
RODNEY ELLIS
COUNTY JUDGE LINA HIDALGO
PCT. 2 PCT. 4
PCT. 3PCT. 1
CHRISTINA (TINA) PETERSEN, PHD, P.E.EXECUTIVE DIRECTOR
PRECINCT 4
PRECINCT 3
PRECINCT 2
PRECINCT 1
PRECINCT 2
PROJECT
LOCATION
ISSUED FOR BIDDING
02/27/2026
JOB NO. 26/0067
ELEVATION
MARK
NAME
ELEVATION
DOOR TYPE NUMBER
PARTITION TYPE
PLAN NOTE x NUMBER
WINDOW MARK
EQUIPMENT TAG
INTERIORS ROOM FINISH TAG
INTERIORS FLOOR FINISH TAG
ACCENT WALL FINISH TAG
LINE OF DEMARCATION B/T DIFFERING
FLOOR FINISHES
Floor Finish
Wall Finish Base Finish
Wall Finish Base Finish
ROOM NAME / NUMBER
STRUCTURAL COLUMN
GRID
DETAIL/SECTION MARK
CALL OUT / DETAIL MARK
A102
SIM1
A103
#/ A101
A102
W.2
NOTE BY SYMBOL - NEW
NOTE BY SYMBOL - DEMOLITION
N
PLAN NORTH
REVISION CLOUD & TAG2
W12
ROOM NAME
INTERIOR ELEVATION MARK
EXTERIOR ELEVATION MARK
PARTITION DESIGNATION
HOURLY "FIRE RESISTIVE RATING"
OR SMOKE RATING
A HB HOSE BIBB
HC HANDICAPPED
HCTLT HANDICAPPED TOILET
HD BD HARD BOARD
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HR HOUR
HO HOISTWAY OPENING
HORIZ HORIZONTAL
HP HORSE POWER
HPL HIGH PRESSURE LAMINATE
HR HOUR
HVAC HEATING, VENTILATION, & AC
AFF ABOVE FINISHED FLOOR
AC ACCESSIBLE
ADJ ADJUSTABLE
ADDL ADDITIONAL
AHJ AUTHORITY HAVING
JURISDICTION
ALT ALTERNATE
ALUM ALUMINUM
AB ANCHOR BOLTS
ARCH ARCHITECTURAL
B BD BOARD
BOT BOTTOM
BLDG BUILDING
BUR BUILT-UP ROOF
C CAB CABINET
CC CENTER TO CENTER
CLG CEILING
CEIL CEILING
CER CERAMIC
CG CORNER GUARD
CJ CONTROL JOINT
CMU CONCRETE MASONRY UNIT(S)
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CT CERAMIC TILE
CTP COUNTERTOP
CTR CENTER
CW CURTAIN WALL
D DECOR DECORATIVE
DEG DEGREE
DEMO DEMOLITION
DTL DETAIL
DET DETAIL
DF DRINKING FOUNTAIN
DIAM/d DIAMETER
DIM DIMENSION
DN DOWN
DR DOOR
DBL DOUBLE
DS DOWNSPOUT
DWG DRAWING
DWR DRAWER
E E EAST
EA EACH
ELEC ELECTRICAL
EL / ELEV ELEVATION
EJ EXPANSION JOINT
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
F FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FEX FIRE EXTINGUISHER
FF FINISHED FLOOR
FFE FURNITURE, FIXTURES, & EQUIP
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FLASH FLASHING
FLR FLOOR
FLUOR FLUORESCENT
FR FIRE RETARDANT / RESISTIVE
FRP FIBER REINFORCED POLYMER
FT FOOT / FEET
FTG FOOTING
FURN FURNITURE
FV FIELD VERIFY
FWC FABRIC WALL COVERING
FPHB FREEZE PROOF HOSE BIBB
G GA GAUGE
GALV GALVANIZED
GB / GWB GYPSUM BOARD
GEN GENERAL
GFRC GLASS FIBER REINF CONCRETE
GFRG GLASS FIBER REINF GYPSUM
GI GALVANIZED IRON
GL GLASS
GND GROUND
GR GRADE
GYP GYPSUM
GYP BD GYPSUM BOARD
H
I ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
J JBOX JUNCTION BOX
JT JOINT
K KD KNOCK DOWN
KO KNOCK OUT
L LAM LAMINATE
LAV LAVATORY
LF LINEAR FEET
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LT LIGHT
M M METER
MACH MACHINE
MANUF MANUFACTURER
MFR MANUFACTURER
MATL MATERIAL
MAX MAXIMUM
MBR MODIFIED BITUMEN ROOF
MECH MECHANICAL
MEMB MEMBRANE
MH MANHOLE
MIN MINIMUM
MLDG MOULDING
MM MILLIMETER
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MTL METAL
MUL MULLION
N N NORTH
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O OC ON CENTER
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OH OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
OPT OPTION / OPTIONAL
P PA PUBLIC ADDRESS (SYSTEM)
PAT PATIENT
PCF POUNDS
PL PLATE / PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
POL POLISHED
PR PAIR
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT PAINT
PTD PAINTED
PTM PATCH TO MATCH
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PLWD PLYWOOD
Q QT QUARRY TILE
QTR QUARTER
QTY QUANTITY
R R / RAD RISER / RADIUS
RA RETURN AIR
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER / REFERENCE
RECEPT RECEPTACLE
REF REFER / REFERENCE
REFL REFLECTED
REG REGISTER
REINF REINFORCED
REQ REQUIRED / REQUIREMENT
RES RESILIENT
REV REVISED / REVISION
RH ROBE HOOK
RM ROOM
RO ROUGH OPENING
ROW RIGHT-OF-WAY
S S SOUTH
SA SUPPLY AIR
SAB SOUND ATTENUATION BATTS
SAN SANITARY
SB SPLASH BLOCK
SC SOLID CORE
STC SOUND TRANSMISSION CLASS
SCHED SCHEDULE / SCHEDULED
SECT SECTION
SF SQUARE FOOT / FEET
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SO STRUCTURAL OPENING
SPEC SPECIFIED
SPR SINGLE PLY ROOFING
SQ SQUARE
SS STAINLESS STEEL
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURE
SUSP SUSPENDED
SYM SYMBOL
SYS SYSTEM
T T TREAD / TOP
TB TOP OF BRICK
TC TOP OF CURB
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TERR TERRAZZO
T&G TONGUE & GROOVE
THK THICK / THICKNESS
THRU THROUGH
TLT TOILET
TO TOP OF
TOC TOP OF CURB / CONCRETE
TOD TOP OF DECK
TOF TOP OF FOOTING
TOJ TOP OF JOIST
TOL TOLERANCE
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TV TELEVISION
TYP TYPICAL
U UCL UNDERCABINET LIGHT
UNO UNLESS NOTED OTHERWISE
UR URINAL
V VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VWC VINYL WALL COVERING
W W WEST / WIDE / WIDTH
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WCOT WAINSCOT
WD WOOD
WEEP WEEP HOLE(S)
WP WATERPROOFING
W/R WATER RESISTANT
WT WEIGHT
WWF WELDED WIRE FABRIC
& AND = EQUALS " INCH
L ANGLE # POUNDS / NUMBER - MINUS
@ AT x TIMES + PLUS
CL CENTERLINE ' FOOT / FEET +/- PLUS / MINUS
GRAPHIC ABBREVIATIONS
STANDARD ABBREVIATIONS
EARTH
GRAVEL
SAND / PRECAST CONCRETE / MORTAR /
GROUT
CONCRETE
PRECAST CONCRETE
2x WOOD / DIMENSIONAL
LUMBER - CONTINUOUS
FINISHED WOOD
INSULATION - BATT, BLANKET OR
ACOUSTICAL
RIGID INSULATION
BRICK
CONCRETE MASONRY UNITS -
CMU
GYPSUM BOARD
GYPSUM BOARD
-- OR --
STEEL
ALUMINUM
PLYWOOD
PRAIRIE OAK DR
VI
NE
C
RE
ST
D
R
KA
NS
AC
K
LN
10700 VINE CREST DR,
HOUSTON TX 77086
COPYRIGHT © 2025 HUITT-ZOLLARS, INC.
PROJECT NO.:
REVIEWED BY:
ISSUES / REVISIONS LOG:
DRAWN BY:
APPROVED BY:
PROJECT ADDRESS:
CONSULTANTS:
PROFESSIONAL SEALS:
OWNER:
PROJECT:
ARCHITECT / ENGINEER:
SHEET TITLE:
SHEET NUMBER:
1001 Fannin Street Suite 4040
Houston, TX 77002
(713) 622-1180 www.huitt-zollars.com
1 2 3 4 5 6
1 2 3 4 5 6
E
D
C
B
A
HUITT-ZOLLARS, INC.
FIRM REGISTRATION NO. F-761
HCFCD PROJECT ID NO.
Z100-00-00-X360
1/
/2
:2 7:
A
M C
:\U se rs \h ar re ol a\
D oc um en ts \H
C
FC
D _M
TS
C
_D is tri bu tio n
C en te r_
AR
C
H _R
_h ar re ol aX
6X
.rv t
HCFCD MTSC -
Distribution Center
10700 VINE CREST DR,
HOUSTON TX 77086
G002
PROJECT
INFORMATION
R313332.19
MMS
LW
MN
SHEET NUMBER SHEET TITLE
GENERAL
G001 COVER
G002 PROJECT INFORMATION
G003 ACCESSIBILITY STANDARDS
G004 FIRE CODE REVIEW
LIFE SAFETY
LS-101 LIFE SAFETY PLANS
STRUCTURE
S001 3D VIEW AND SHEET LIST
S101 GENERAL STRUCTURAL CRITERIA
S201 FOUNDATION PLAN
S202 SECOND FLOOR FRAMING PLAN
S203 ROOF FRAMING PLAN
S401 TYPICAL FOUNDATION DETAILS
S501 TYPICAL FRAMING DETAILS
S502 TYPICAL COMPOSITE FRAMING DETAILS
S503 FLOOR FRAMING DETAILS
S504 FRAMING DETAILS
S601 PANEL ELEVATIONS
ARCHITECTURE
A0.10 SITE PLAN
AD1.00 DEMOLITION PLAN LEVEL 1 & 2
AD1.60 DEMO RCP PLAN LEVEL 1 & 2
A1.00 FLOOR PLAN LEVEL 1 & 2
A1.40 RESTROOM ENLARGED PLANS
A1.41 RESTROOM ENLARGED PLANS
A1.42 ENLARGED PLANS
A1.43 ENLARGED PLANS & APPLIANCE SCHEDULE
A1.60 REFLECTED CEILING PLAN LEVEL 1 & 2
A1.70 POWER PLANS
A1.80 FINISH PLAN
A-3.00 BUILDING SECTIONS
A5.00 DOOR & FINISH SCHEDULE & DETAILS
A5.10 TYPICAL PARTITIONS AND DETAILS
A6.00 INTERIOR ELEVATIONS
A7.00 ELEVATOR PLANS, SECTIONS, & DETAILS
A7.10 STAIRS
A7.20 MILLWORK SECTIONS & DETAILS
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES AND LEGEND
E-002 ELECTRICAL SITE PLAN
ED101 ELECTRICAL DEMOLITION PLAN - LEVEL 1
ED102 ELECTRICAL DEMOLITION PLAN - LEVEL 2
EL101 ELECTRICAL LIGHTING PLAN - LEVEL 1
EL102 ELECTRICAL LIGHTING PLAN - LEVEL 2
EP101 ELECTRICAL POWER PLAN - LEVEL 1
EP102 ELECTRICAL POWER PLAN - LEVEL 2
EQ101 ELECTRICAL EQUIPMENT PLAN - LEVEL 1
EQ102 ELECTRICAL EQUIPMENT PLAN - LEVEL 2
EZ501 ELECTRICAL DETAILS
EZ601 ELECTRICAL SCHEDULES
EZ701 ELECTRICAL DIAGRAMS
EZ702 ELECTRICAL DIAGRAMS - BID ALTERNATE
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES AND LEGEND
FA101 FIRE ALARM PLAN - LEVEL 1
FA102 FIRE ALARM PLAN - LEVEL 2
MECHANICAL
M-001 MECHANICAL GENERAL NOTES AND LEGENDS
MD101 MECHANICAL DEMOLITION PLAN - LEVEL 1
MD102 MECHANICAL DEMOLITION PLAN - LEVEL 2
MEP02 MECHANICAL ELECTRICAL PLUMBING ROOF PLAN
MEPD01 MECHANICAL ELECTRICAL PLUMBING DEMOLITION ROOF PLAN
MH101 MECHANICAL PLAN - LEVEL 1
MH102 MECHANICAL PLAN - LEVEL 2
MP101 MECHANICAL PIPING & CONTROLS PLAN - LEVEL 1
MP102 MECHANICAL PIPING & CONTROLS PLAN - LEVEL 2
MZ401 MECHANICAL ENLARGED PLANS
MZ402 MECHANICAL ENLARGED PLANS
MZ403 MECHANICAL ENLARGED PLANS
MZ501 MECHANICAL DETAILS
MZ502 MECHANICAL DETAILS
MZ601 MECHANICAL SCHEDULES
MZ602 MECHANICAL SCHEDULES
MZ801 MECHANICAL CONTROLS
MZ802 MECHANICAL CONTROLS
PLUMBING
P-001 PLUMBING GENERAL NOTES AND LEGEND
PD101 PLUMBING DEMOLITION PLAN - LEVEL 1
PJ101 PLUMBING UNDERSLAB PLAN
PJ102 PLUMBING PLAN - LEVEL 1
PJ103 PLUMBING PLAN - LEVEL 2
PZ501 PLUMBING DETAILS
PZ502 PLUMBING DETAILS
PZ601 PLUMBING SCHEDULES
PZ701 PLUMBING RISER DIAGRAM SUPPLY
PZ702 PLUMBING RISER DIAGRAM - WASTE & VENT
COMMUNICATIONS
T0.01 LEGEND AND NOTES - COMMUNICATIONS
T1.00 FLOOR PLAN LEVEL 1 & 2 - COMMUNICATIONS
T3.01 TELECOM ROOM DETAILS - COMMUNICATIONS
T4.01 GENERAL DETAILS - COMMUNICATIONS
AV INFRASTRUCTURE
AVI0.01 LEGEND AND NOTES - AV INFRASTRUCTURE
AVI1.00 FLOOR PLAN LEVEL 1 & 2 - AV INFRASTRUCTURE
AVI1.60 REFLECTED CEILING PLAN LEVEL 1 & 2 - AV INFRASTRUCTURE
AVI4.01 GENERAL DETAILS - AV INFRASTRUCTURE
AV5.01 AV SIGNAL FLOW DIAGRAMS
SECURITY
SC0.01 LEGEND AND NOTES - SECURITY
SC1.00 FLOOR PLAN LEVEL 1 & 2 - SECURITY
SC3.01 DOOR ELEVATION DETAILS - SECURITY
SC4.01 GENERAL DETAILS - SECURITY
LANDSCAPE
L-101 LANDSCAPE PLAN
L-201 LANDSCAPE NOTES
TOTAL: 94
SHEET INDEXGENERAL NOTES
DO NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES. IN THE EVENT OF OMISSION OF NECESSARY DIMENSION(S), NOTIFY THE ARCHITECT
IN WRITING.
ALL DIMENSIONS ON 1/8", & 1/4" SCALE PLANS ARE TO THE FACE OF MASONRY, CONCRETE, OR THE FACE OF GYPSUM BOARD, UNLESS NOTED
OTHERWISE. ALL MASONRY DIMENSIONS ARE ACTUAL, UNLESS NOTED OTHERWISE.
VERIFY ALL DIMENSIONS, CONDITIONS, EXISTING CONSTRUCTION, AND GRADES AT THE JOB SITE. NOTIFY ARCHITECT IN WRITING OF ANY
DISCREPANCIES OR CONFLICTS.
VERIFY SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORK AND EQUIPMENT TO BE INSTALLED OR RELOCATED WHETHER FURNISHED BY
OWNER OR BY CONTRACTOR(S) BEFORE ANY CONSTRUCTION PERTAINING TO SAME HAS BEGUN.
VERIFY AND COORDINATE THE SIZE AND LOCATION OF ALL THE OPENINGS FOR STRUCTURAL, MECHANICAL, & ELECTRICAL WORK AND
EQUIPMENT WITH ALL TRADES INVOLVED.
CEILING HEIGHTS INDICATED ON THE ROOM FINISH SCHEDULE ARE TAKEN FROM THE FINISH FLOOR ELEVATION. VERIFY THE SIZE, LOCATION, & CHARACTERISTICS OF ALL MECHANICAL, ELECTRICAL, AND STRUCTURAL ITEMS BEFORE CEILING CONSTRUCTION IS BEGUN. COORDINATE WITH
ALL TRADES TO MAINTAIN SCHEDULED CEILING HEIGHTS.
DEMOLITION INFORMATION IS SHOWN THROUGHOUT THE DRAWINGS AND IS NOT LIMITED TO THE DEMOLITION DRAWINGS.
COORDINATE VISUAL APPEARANCE OF ALL ELECTRICAL, MECHANICAL, & PLUMBING WORK AT AREAS W/ EXPOSED CEILING/STRUCTURE. RUN ALL PIPES, CONDUITS, DUCTWORK, ETC., ORTHOGONAL WITH STRUCTURE W/ ALL TURNS & BENDS AT 90 DEGREES.
VERIFY THAT REQUIRED OPERATION AND MAINTENANCE CLEARANCES ARE PROVIDED FOR ALL EQUIPMENT ITEMS.
INSTALL ALL ITEMS IN ACCORDANCE W/ THE MANUFACTURER'S WRITTEN INSTRUCTIONS, EXCEPT THAT THE SPECIFICATIONS HEREIN, WHERE MORE STRINGENT, SHALL SUPERCEDE. NOTIFY THE ARCHITECT IN WRITING OF ANY CONFLICTS.
PROJECT NAME: MTSC DISTRIBUTION CENTER 2ND FLOOR BUILD OUT
OWNER'S ADDRESS: 10700 VINE CREST DR, HOUSTON, TX 77086
PROJECT LOCATION: 10700 VINE CREST DR, HOUSTON, TX 77086
OWNER'S CONTACT: RODERICK DIXON, RODERICK.DIXON@HCFCD.HCTX.NET
ARCHITECT'S CONTACT: MARCY NEWMAN, MNEWMAN@HUITT-ZOLLARS.COM
PROJECT SUMMARY: EXPANSION OF THE EXISTING FIRST FLOOR AND SECOND FLOOR.
BUILDING AREAS: 15,000 SF
(APPROXIMATE)
APPLICABLE CODES:
2018 INTERNATIONAL BUILDING CODE (IBC) W/ HARRIS COUNTY AMENDMENTS
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL FIRE CODE (IFC) W/ HARRIS COUNTY AMENDMENTS
2015 INTERNATIONAL MECHANICAL CODE (IMC), STATE OF TEXAS ADOPTED - NOT REVIEWED/INSPECTED BY HARRIS COUNTY 2015 INTERNATIONAL PLUMBING CODE (IPC), STATE OF TEXAS ADOPTED - NOT REVIEWED/INSPECTED BY HARRIS COUNTY 2014 NATIONAL ELECTRIC CODE (NEC, NFPA 70), STATE OF TEXAS ADOPTED - NOT REVIEWED/INSPECTED BY HARRIS COUNTY
2010 AMERICANS WITH DISABILITIES ACT (ADA)
2012 TEXAS ACCESSIBILITY STANDARD (TAS)
DESIGN CRITERIA
PROJECT LOCATION MAPMATERIAL INDICATIONS
GRAPHIC SYMBOLS
MARK DATE DESCRIPTION
1 04/18/25 DD COORDINATION
2 06/16/25 50% CD
3 07/28/25 95% CD
4 08/28/25 ISSUE FOR PERMIT & BID
5 11/26/25 PERMIT CORRECTIONS
6 12/09/25 BID-READY SET
DOMINANT DIRECTION OF
TRAVEL
FIG. 302.2
CARPET PILE HEIGHT
FIG. 302.3
ELONGATED OPENINGS IN FLOOR OR
GROUND SURFACES
1/2 " M
AX
1/2" MAX.
LO
NG
D
IM
EN
SI
ON
P
ER
PE
ND
IC
UL
AR
T O
DO
MI
NA
NT
D
IR
EC
TI
ON
O
F
TR
AV
EL
FIG. 303.3
BEVELED CHANGE IN LEVEL
FIG. 303.2
VERTICAL CHANGE IN LEVEL
1/4 " M
AX
1/4
1/4
1/2
FIG. 304.3.2
T-SHAPED TURNING
SPACE
60" MIN.
" M
IN
" M
IN
36" MIN.
12" MIN.
" M
IN
" M
IN
12" MIN.
FIG. 802.1.2
WIDTH OF WHEELCHAIR SPACES IN ASSEMBLY AREAS
(a)
SINGLE SPACE
(b)
TWO SPACES
(b)
SIDE ENTRY
(a)
FRONT OR REAR
ENTRY
FIG. 802.1.3
DEPTH OF WHEELCHAIR SPACES IN ASSEMBLY AREAS
NOTE: 802.3
COMPANION SEAT SHALL
COMPLY
WITH 802.3
" M
IN
" M
IN
36" MIN. 33" MIN. 33" MIN.
FIG. 305.3
CLEAR FLOOR OR
GROUND SPACE
FIG. 305.5
POSITION OF CLEAR FLOOR
OR GROUND SPACE
(a)
FORWARD
(b)
PARALLEL
FIG. 305.7.1
MANEUVERING CLEARANCE
IN AN ALCOVE,
FORWARD APPROACH
FIG. 305.7.2
MANEUVERING CLEARANCE
IN AN ALCOVE,
PARALLEL APPROACH
48" MIN.
" M
IN
" M
IN
48" MIN.48
" M
IN
30" MIN.
36" MIN. 60" MIN.
X
X
FIG. 306.2
TOE CLEARANCE
(a)
ELEVATION
(b)
PLAN
FIG. 306.3
KNEE CLEARANCE
(a)
ELEVATION
(b)
PLAN
" M
IN
" M
IN
8" MIN.
" M
IN
11" MIN.
9" M
IN
9"
6" MAX.
17" - 25"
25" MAX.
FIG. 307.4
VERTICAL CLEARANCE
FIG. 307.2
LIMITS OF PROTRUDING
OBJECTS
FIG. 307.3
POST-MOUNTED PROTRUDING OBJECTS
(a) (b)
" M
AX
X
4" MAX.
X
X ≥ 8
0"
12" MAX. 12" MAX.
" M
AX
" M
IN
X > 12"
X > 12"
FIGURE 308.2.1
UNOBSTRUCTED
FORWARD REACH
FORWARD OR SIDE REACH AGES 3 AND 4 AGES 5 THROUGH 8 AGES 9 THROUGH 12
HIGH ( MAXIMUM) 36 in. (915 mm) 40 in. (1015 mm) 44 in. (1120 mm)
LOW (MINIMUM) 20 in. (510 mm) 18 in. (455 mm) 16 in. (405 mm)
CHILDREN'S REACH RANGES
FIGURE 308.2.2
OBSTRUCTED HIGH
FORWARD REACH
FIGURE 308.3.1
UNOBSTRUCTED SIDE
REACH
(a)
(b)
FIGURE 308.3.2
UNOBSTRUCTED HIGH SIDE
REACH
(a)
(b)
" M
AX
20" MAX.
" M
AX
>20" - 25" MAX.
" M
IN
" M
AX
10" MAX.
" M
IN
" M
AX
10" MAX.
" M
AX
" M
AX
>10" - 24" MAX.
" M
AX
" M
AX
(c)
FOLDING DOOR
(b)
SLIDING DOOR
(a)
HINGED DOOR
FIG. 404.2.3
CLEAR WIDTH OF DOORWAYS
(a)
FRONT APPROACH, PULL SIDE
(b)
FRONT APPROACH, PUSH SIDE
(c)
FRONT APPROACH, PUSH SIDE, DOOR
PROVIDED WITH BOTH CLOSER AND LATCH
(d)
HINGE APPROACH, PULL SIDE
(e)
HINGE APPROACH, PULL SIDE
(f)
HINGE APPROACH, PUSH
SIDE
FIG. 404.2.4.1
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
(g)
HINGE APPROACH, PUSH SIDE, DOOR
PROVIDED WITH BOTH CLOSER AND LATCH
(h)
LATCH APPROACH, PULL
SIDE
(i)
LATCH APPROACH, PULL SIDE, DOOR
PROVIDED WITH CLOSER
(j)
LATCH APPROACH, PUSH SIDE,
(k)
LATCH APPROACH, PUSH SIDE,
DOOR PROVIDED WITH CLOSER
(a)
FRONT APPROACH
(b)
SIDE APPROACH
(c)
POCKET OR HINGE APPROACH
(e)
STOP OR LATCH APPROACH
FIG. 404.2.4.2
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS
(a)
PULL SIDE
(b)
PUSH SIDE
(c)
PUSH SIDE, DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
FIG. 404.2.4.3
MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
(a)
(b)
(c)
FIG. 404.2.6
DOORS IN SERIES AND GATES IN SERIES
" M
IN
18" MIN. 60
" M
IN
36" MIN.48
" M
IN
" M
IN
" M
IN
12" MIN.
" M
IN
42" MIN.
22" MIN.
" M
IN
22" MIN.
" M
IN
24" MIN.
" M
IN
24" MIN. 24" MIN.
" M
IN
24" MIN.
" M
IN
18" MIN.
X
8"60 " M
IN
X
8"
" M
IN
" M
IN
X
8"
12" MIN.
48" MIN.
48" MIN.
48" MIN.
" M
IN
22" MIN 42
" M
IN
" M
IN
24" MIN42
" M
IN
32" MIN
32" MIN
32" MIN
90.
0°
(a) (b)
FIG. 609.2.2
GRAB BAR NON-CIRCULAR CROSS SECTION
4" - 4.8" PERIMETER
(a)
PROJECTING OBJECTS
(b)
RECESSED OBJECTSFIG. 609.3
SPACING OF GRAB BARS
2" MAX.
2" MAX.
1 1 /2"
M
IN
" M
IN
FIG. 604.5.1
SIDE WALL GRAB BAR AT WATER
CLOSETS
(a)
WHEELCHAIR ACCESSIBLE
WATER CLOSETS
(b)
AMBULATORY ACCESSIBLE
WATER CLOSETS
FIG. 604.2
WATER CLOSET LOCATION
FIG. 604.3.1
SIZE OF CLEARANCE AT WATER
CLOSET
FIG. 604.5.2
REAR WALL GRAB BAR AT WATER CLOSETS
TRANSFER
SIDE
FIG. 604.7
DISPENSER OUTLET LOCATION
(a)
ADULT WALL HUNG
WATER CLOSET
FIG. 604.8.1.1
SIZE OF WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT
ALTERNATE
DOOR
LOCATION
FIG. 604.8.1.2
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT
DOORS
(a)
ELEVATION
ADULT
(b)
ELEVATION
CHILDREN
(c)
PLAN
FIG. 604.8.1.4
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE
FIG. 604.8.2
AMBULATORY ACCESSIBLE TOILET COMPARTMENT
11 TO 12 IN.
(280 TO 305 MM)
12 TO 15 IN.
(305 TO 380 MM.)
15 TO 17 IN.
(380 TO 430 MM.)
18 TO 20 IN.
(280 TO 305 MM.)
20 TO 25 IN.
(510 TO 635 MM.)
25 TO 27 IN.
(635 TO 685 MM.)
14 IN. (355 MM.) 14 TO 17 IN.
(355 TO 430 MM.)
17 TO 19 IN.
(430 TO 485 MM.)
WATER CLOSET CENTERLINE
TOILET SEAT HEIGHT
GRAB BAR HEIGHT
DISPENSER HEIGHT
AGES 3 & 4 AGES 5
THROUGH 8
AGES 9
THROUGH 12
12 IN. (305 MM.) 12 TO 15 IN.
(305 TO 380 MM.)
15 TO 18 IN.
(380 TO 455 MM.)
ADVISORY SPECIFICATIONS FOR WATER CLOSETS SERVING CHILDREN AGES 3 THROUGH 12
FIG. 604.3.2
(EXCEPTION) OVERLAP OF WATER CLOSET
CLEARANCE IN RESIDENTIAL DWELLING
NOTE: 604.4 SEATS
THE SEAT HEIGHT OF A WATER
CLOSET ABOVE THE FINISH
FLOOR SHALL BE 17 INCHES
MINIMUM AND 19 INCHES
MAXIMUM MEASURED TO THE
TOP OF THE SEAT. SEATS SHALL
NOT BE SPRUNG TO RETURN TO
A LIFTED POSITION.
PARTITIONPARTITION
12" MAX. 42" MIN.
54" MIN.
16" - 18"
17" - 19"
" M
IN
60" MIN.
12" MIN.24" MIN.
36" MIN.
7" - 9"
" M
IN
" M
AX
" M
IN
60" MIN.
" M
IN
60" MIN.
4" MAX.
4" M
AX
" M
IN
6" MIN.
9" M
IN
6" MIN.
" M
IN
6" MIN.
6" M
IN
35" - 37"
" M
IN
60" MIN.
18" MIN.
" M
IN
FIG. 703.4.1
HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND
FIG. 703.7.2
INTERNATIONAL SYMBOLS
FIG. 703.7.2.2
INT. SYMBOL OF TTY
FIG. 703.7.2.4
INT. SYMBOL OF ACCESS FOR
HEARING LOSS
FIG. 703.7.2.1
PROPORTIONS INT. SYMBOL OF
ACCESSIBILITY
FIG. 703.7.2.3
VOLUME CONTROL TELEPHONE
AR
EA
OF
RE
FU
GE
AREA OF
MEN
FIG. 703.6.1
PICTOGRAM FIELD
HEIGHT TO FINISH FLOOR OR GROUND
FROM BASELINE OF CHARACTER
HORIZONTAL
VIEWING
DISTANCE
MINIMUM CHARACTER HEIGHT
40 IN. (1015MM) TO LESS THAN
OR EQUAL TO 70 IN.(1780 MM)
LESS THAN 72
IN. (1830 MM) 5/8 IN. (16 MM)
40 IN. (1015 MM) TO LESS THAN OR
EQUAL TO 70 IN. (1780 MM)
72 IN. (1830 MM)
AND GREATER
5/8 IN (16 MM), PLUS 1/8 IN. (3.2 MM)
PER FOOT (305 MM) OF VIEWING
DISTANCE ABOVE 72 IN. (1830 MM)
GREATER THAN 70 IN (1780 MM) TO LESS
THAN OR EQUAL TO 120 IN (3050 MM)
LESS THAN 180
IN (5470 MM) 2 IN (51 MM)
GREATER THAN 70 IN. (1780 MM) TO
LESS THAN OR EQUAL TO 120 IN (3050 MM)
180 IN. (4560 MM)
AND GREATER
2 IN. (51 MM), PLUS 1/8 IN. (3.2 MM)
PER FOOT (3-5 MM) OF VIEWING
DISTANCE ABOVE 180 IN. (4570 MM)
GREATER THAN 120 IN. (3050 MM)
LESS THAN 21
FEET (6400 MM) 3 IN. (75 MM)
HORIZONTAL
VIEWING DISTANCE
3 IN. (75 MM), PLUS 1/8 IN. (3.2 MM) PER
FOOT 305 MM) OF VIEWING DISTANCE
ABOVE 21 FEET (6400 MM)
GREATER THAN 120 IN. (3050 MM)
TABLE 703.5.5 VISUAL CHARACTER HEIGHT
FIG. 703.4.2
LOCATION OF TACTILE SIGNS AT DOORS
CENTERED ON
TACTILE
CHARACTERS
" M
IN
" M
AX
6" M
IN
18" MIN.
" M
IN
REFUGE
FIG. 605.2
HEIGHT AND DEPTH OF URINALS
(a)
WALL HUNG TYPE
(b)
STALL TYPE
13 1/2" MIN.
" M
AX
13 1/2" MIN.
FIG. 602.5
DRINKING FOUNTAIN SPOUT
LOCATION
NOTE: 602.4 SPOUT HEIGHT
SPOUT OUTLETS SHALL BE
36" INCHES MAXIMUM ABOVE THE
FINISH FLOOR OR GROUND
5" MAX. 15" MIN.
COPYRIGHT © 2025 HUITT-ZOLLARS, INC.
PROJECT NO.:
REVIEWED BY:
ISSUES / REVISIONS LOG:
DRAWN BY:
APPROVED BY:
PROJECT ADDRESS:
CONSULTANTS:
PROFESSIONAL SEALS:
OWNER:
PROJECT:
ARCHITECT / ENGINEER:
SHEET TITLE:
SHEET NUMBER:
1001 Fannin Street Suite 4040
Houston, TX 77002
(713) 622-1180 www.huitt-zollars.com
1 2 3 4 5 6
1 2 3 4 5 6
E
D
C
B
A
HUITT-ZOLLARS, INC.
FIRM REGISTRATION NO. F-761
HCFCD PROJECT ID NO.
Z100-00-00-X360
1/
/2
:2 7:
A
M C
:\U se rs \h ar re ol a\
D oc um en ts \H
C
FC
D _M
TS
C
_D is tri bu tio n
C en te r_
AR
C
H _R
_h ar re ol aX
6X
.rv t
HCFCD MTSC -
Distribution Center
10700 VINE CREST DR,
HOUSTON TX 77086
G003
ACCESSIBILITY
STANDARDS
R313332.19
MMS
LW
MN
MARK DATE DESCRIPTION
1 04/18/25 DD COORDINATION
2 06/16/25 50% CD
3 07/28/25 95% CD
4 08/28/25 ISSUE FOR PERMIT & BID
COPYRIGHT © 2025 HUITT-ZOLLARS, INC.
PROJECT NO.:
REVIEWED BY:
ISSUES / REVISIONS LOG:
DRAWN BY:
APPROVED BY:
PROJECT ADDRESS:
CONSULTANTS:
PROFESSIONAL SEALS:
OWNER:
PROJECT:
ARCHITECT / ENGINEER:
SHEET TITLE:
SHEET NUMBER:
1001 Fannin Street Suite 4040
Houston, TX 77002
(713) 622-1180 www.huitt-zollars.com
1 2 3 4 5 6
1 2 3 4 5 6
E
D
C
B
A
HUITT-ZOLLARS, INC.
FIRM REGISTRATION NO. F-761
HCFCD PROJECT ID NO.
Z100-00-00-X360
/9
/2
4:
:5
PM
C :\U se rs
\h ar re ol a\ D oc um en ts
\H C
FC
D
_M
TS
C _D is tri bu tio n C en te r_
AR
C H
_R
_h ar re ol aX
6X .rv t
HCFCD MTSC -
Distribution Center
10700 VINE CREST DR,
HOUSTON TX 77086
G004
FIRE CODE REVIEW
R313332.19
LTH
LW
Approver
MARK DATE DESCRIPTION
1 04/18/25 DD COORDINATION
2 06/16/25 50% CD
3 07/28/25 95% CD
4 08/28/25 ISSUE FOR PERMIT & BID
5 11/26/25 PERMIT CORRECTIONS
6 12/09/25 BID-READY SET
X
X
II-B, NOT SPRINKLERED
55'
1 1
10700 VINE CREST DR
HOUSTON, TX 77086
1235860010001
2 32'-6"
N/A
N/A
WELLNESS (106)B 70.72 150 1
ELEC. (105)ACC 40.19 300 1
ELEC. (104)ACC 42.29 300 1
JAN. (102)ACC 40.54 300 1
OFFICE (101)B 111.49 150 1
LOCKER (110)LCKS 502.14 50 11
WAREHOUSE (112)S-1 4,476.99 500 9
HYDROLOGY STORAGE (113)S-1 585.4 500 2
SURVEY STORAGE (114)S-1 300.11 500 1
BREAK ROOM (201)AUC 307.4 15 21
STORAGE (213)ACC 92.87 300 1
PHONE BOOTH (204)B 57.97 150 1
I.T. (206)ACC 68.15 300 1
ALERT ROOM (208)B 1,092.3 150 8
OFFICE (210)B 127.93 150 1
OFFICE (211) B 127.61 150 1
OFFICE (214)B 112.01 150 1
OFFICE (215)B 112.01 150 1
OFFICE (216)B 107.89 150 1
CONF. ROOM (207)B 315.75 150 3
OPEN OFFICE (217)B 2,827.53 150 19
OFFICE (218)B 159.12 150 1
ALERT COMMAND (219)B 159.3 150 1
I.T. SUPPORT (220)B 150.76 150 1
I.T. STOR. (212)ACC 98 150 1
TOTAL L1 31
12,607.44
14,788.00
$3,000,000.00
X
X
2 A-1.00
4 A-1.00
X
LS-1.01 & A7.10
LS-1.01
X
PRIMARY USE - B, BUSINESS 200' 175' LS-1.01
X
X
7,500 SF
14,788.00
NORTHWEST PARK MUNICIPAL UTILITY DISTRICT
B, E, M A B C A1.00, A1.60 & A5.10
S B B C A1.00, A1.60 & A5.10
X
PALLETIZED & SOLID PILE STORAGE
A1.00
OFFICE SUPPLIES, UNIFORMS, VEHICLE AND EQUIPMENT PARTS, CONSTRUCTION
SUPPLIES, TEMPORARY FURNITURE, BOTTLED WATER, FIRE EXTINGUISHERS,
INACTIVE PROJECT FILES AND DRAWINGS, COMPUTER AND ACCESSORIES,
ELECTRONIC EQUIPMENT, PALLETIZED GOODS, ETC.
NO HIGH-PILED STORAGE
X
X
X
X
X
X
X
X
X
X
X
X
X
X
HCFCD MTSC DISTRIBUTION CENTER
CHESTER NIELSEN
G001 A7.20
08/28/2025CHESTER NIELSEN
1 HR UL U465, A6/A5.10, UL901, A4/A5.10 PROVIDE
RATED OPENING SELF-CLOSER
X
X ≥ 30 X ≥ 30 X ≥ 30 X ≥ 30
X
X
X
X
X
X
X
X
X
X
X
A0.10
A0.10 A0.10
X
TABS2026000581
X
THIS BUILDING SERVES AS A HUB FOR ADMINISTRATIVE FUNCTIONS, STORAGE, AND DISTRIBUTION. IT SUPPORTS OFFICE
OPERATIONS, HOUSES INVENTORY AND EQUIPMENT, AND FACILITATES THE EFFICIENT MOVEMENT OF GOODS AND MATERIALS.
N/A
LEVEL 2
LEVEL 1
X
X
X
X
X
X
2,500 2 HRS
X
2509110115
X A1.00 4
X
3/4 HR A5.00, PROVIDE RATED OPENING SELF-CLOSER
A5.00, PROVIDE RATED OPENING SELF-CLOSER
SECONDARY USE - S-1, STORAGE 200' 68'-10" LS-1.01
GRAND TOTAL 94
TOTAL L2 63
VESTIBULE (100)B 406.24 150 3
DN
DN
0;
0;0;
42 SF
ELEC
ACC
40 SF
ELEC.
ACC
71 SF
WELLNESS
B
502 SF
LOCKER
LCKS
111 SF
OFFICE
B
41 SF
JAN.
ACC
4,477 SF
WAREHOUSE
S-1
300 SF
S-1
STORAGE
585 SF
S-1
STORAGE
REQ'D
W
PROV'D
W
34"3"
EXIT 6
REQ'D
W
PROV'D
W
3" 36"
EXIT 3
TD - 58'-4"
CPT - 34'-8"
TD - 88'-3"
CPT - 36'-5"
TD - 31'-8"
TD - 46'-2"
REQ'D
W
PROV'D
W
2" 34"
EXIT 5
TD - 64'-0"
FE
C
FEC
70 SF
ELEV.
X
52 SF
RESTR.
X
69 SF
ADA RESTR.
X
44 SF
SHWR.
X
72 SF
ADA SHWR.
X
REQ'D
W
PROV'D
W
2" 36"
EXIT 4
TD - 68'-10"
406 SF
VESTIBULE
B
447 SF
BREAK RM.
AUC
93 SF
STOR.
ACC
58 SF
PHONE BOOTH
B
68 SF
I.T.
ACC
1,092 SF
ALERT ROOM
B
128 SF
OFFICE
B
128 SF
FILE STOR.
B
112 SF
OFFICE
B
112 SF
OFFICE
B
107 SF
OFFICE
B
316 SF
CONF.
B
2,827 SF
OPEN OFFICE
B
150159 SF
OFFICE
B
159 SF
ALERT COMMAND
B
151 SF
IT SUPPORT
B
TD - 117'-8"
CPT - 28'-11"
TD -
54'-4"
CPT - 3
8'-8"
TD - 109'-6"
REQ'D
W
PROV'D
W
7" 36"
EXIT 2
FEC
FEC
TD - 1
33'-0"
TD - 99'-8"
CPT - 39'-4"
69 SF
ELEV.
X
56 SF
ADA RESTR.
X
55 SF
RESTR.
X
98 SF
I.T. STOR.
ACC
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
ALL CONDUIT, PIPES, DUCTS, AND MIX. PENETRATIONS THROUGH RATED WALLS, FLOORS, AND
ROOFS MUST BE PROTECTED WITH UL-RATED THROUGH-PENETRATION FIRESTOPPING
SYSTEMS.
UL ASSEMBLIES INDICATED ON THE PARTITION TYPE DETAILS ESTABLISH A BASIS FOR
PERFORMANCE. OTHER ASSEMBLIES MAY BE CONSIDERED AT THE DISCRETION OF THE
ARCHITECT IF EQUIVALENT PERFORMANCE CRITERIA IS PROVIDED.
SUBSTITUTION OF PROPOSALS SHALL INCLUDE CHANGES REQUIRED TO ALL COMPONENTS OF
THE ASSEMBLY.
WHERE RATED PARTITIONS ABUT EXTERIOR WALLS, FLOOR DECKS, OR ROOF DECKS, JOINTS
SHALL BE SEALED WITH UL-RATED FIRE-RESISTIVE JOINT SYSTEMS.
REFER TO PARTITION TYPE INFORMATION FOR WALL CONSTRUCTION AND RATED ASSEMBLY
UL DESIGNS.
IBC = INTERNATIONAL BUILDING CODE. NFPA = NATIONAL FIRE PROTECTION ASSOCIATION.
PENETRATIONS OF FIRE-RATED PARTITIONS, WALLS, OR FLOORS BY DATA AND
COMMUNICATION WIRING OR CABLE SHALL BE MADE THROUGH MODULAR, RE-ENTERABLE
FIRESTOPPING DEVICES CONTAINING SELF-SEALING INTUMESCENT INSERTS PER
SPECIFICATION.
LIFE SAFETY ABBREVIATIONS
IBC FUNCTION OF SPACE (CHAPTER 10) OR NFPA OR NFPA 101 USE (CHAPTER 7)
ACC
AUC
B
LCKS
EXE
UOC
IBC: ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM (SF/300)
NFPA 101: STORAGE USE IN OTHER OCCUPANCIES (SF/500)
IBC: ASSEMBLY, UNCONCENTRATED ((TABLES AND CHAIRS) (SF/15)
NFPA 101: LESS CONCENTRATED USE, WITHOUT FIXED SEATING (SF/15)
IBC: BUSINESS AREAS (SF/150)
NFPA 101: BUSINESS USE (SF/100)
IBC: LOCKER ROOMS (SF/50)
NFPA 101: NO EQUIVALENT
IBC: EXERCISE ROOMS (SF/50)
NFPA 101: EXERCISE ROOMS WITH EQUIPMENT (SF/50)
IBC: UNOCCUPIED SPACES (-/SF)
NFPA 101: NO EQUIVALENTOCCUPANCY
CLASSIFICATION TYPE OF CONSTRUCTION
A, B, E, F, M, S, U
TYPE II
B
NOT SPRINKLERED
HEIGHT ALLOWED
HEIGHT PROVIDED
32'-6"
OCCUPANCY
CLASSIFICATION
TYPE OF CONSTRUCTION
TYPE II
B
NOT SPRINKLERED
B
S-1
STORIES ALLOWED
STORIES PROVIDED
OCCUPANCY
CLASSIFICATION
TYPE OF CONSTRUCTION
TYPE II
B
NOT SPRINKLERED
B
S-1
23,000
17,500
SQUARE FEET ALLOWED
SQUARE FEET PROVIDED
17,500
7,500
OCCUPANCY
H-5
NSNSNSNSNSNSNSNSNSS NS
H-3, H-4H-2H-1Be, F-1
M, S-1 F-2, S-2, URaI-2I-1a, I-3 I-4A, E
A, E
I-1a, I-3, I-4
I-2
Ra
F-2, S-2, U
Be, F-1, M, S-1
H-1
H-2
H-3, H-4
H-5
N N 1 2
N N
N N
N N
N N
N N
N NP
N NP
1d NP
N NP
2 NP 1 2 N 1 1 2 NP NP 3 4 2 3 2 NP
S S S S S S S S S
NP
NP
NP
NP
NP
NP
NP
NP
NPNPNPNPNP
1 NP
2 NP 1 NP
2 NP
1c 1
2 2NP
2c
NP
NP NP
NP NP
NP NP
NP NP
NP NP
NP
NP
NP
3 4
2 3 2
NP
NP
NP
2 3
BUILDING ELEMENT
TYPE II
B
0PRIMARY STRUCTURAL FRAME (SEE SECTION 202)
BEARING WALLS:
EXTERIORe, f
INTERIOR
NONBEARING WALLS AND PARTITIONS:
EXTERIOR
INTERIORd
SEE TABLE 602
0FLOOR CONSTRUCTION AND ASSOCIATE SECONDARY MEMBERS
(SEE SECTION 202)
0cROOF CONSTRUCTION AND ASSOCIATE SECONDARY MEMBERS
(SEE SECTION 202)
FIRE SEPARATION
DISTANCE = X (FEET)
TYPE OF
CONSTRUCTION
OCCUPANCY GROUP
B, S-1
0X ≥ 30 ALL
GROUP
B, E, M, R-1
S
TYPE OF CONSTRUCTION
CORRIDORS AND
ENCLOSURE FOR EXIT
ACCESS STAIRWAYS
AND RAMPS
ROOMS AND
ENCLOSED
SPACESc
INTERIOR EXIT
STAIRWAYS AND
RAMPS AND EXIT
PASSAGEWAYSa, b
A
B
B
B
C
C
HIGH HAZARD
OCCUPANCY
MINIMUM-RATED SINGLE
EXTINGUISHER
MAXIMUM FLOOR AREA
PER UNIT OF A
MAXIMUM FLOOR AREA
FOR EXTINGUISHERB
MAXIMUM DISTANCE OF
TRAVEL TO EXTINGUISHER
MODERATE
HAZARD OCCUPANCY
LOW HAZARD
OCCUPANCY
4-Aa2-A2-Ac
1,000 SQUARE FEET1,500 SQUARE FEET3,000 SQUARE FEET
11,250 SQUARE FEET11,250 SQUARE FEET11,250 SQUARE FEET
75 FEET75 FEET75 FEET
MINIMUM
WIDTH (INCHES)
ANY FACILITY NOT LISTED IN THIS TABLE
ACCESS TO AND UTILIZATION OF MECHANICAL, PLUMBING, OR ELECTRICAL
SYSTEMS OR EQUIPMENT
WITH AN OCCUPANT LOAD OF LESS THAN 50
WITHIN A DWELLING UNIT
IN GROUP E WITH A CORRIDOR HAVING AN OCCUPANT LOAD OF 100 OR MORE
IN CORRIDORS AND AREAS SERVING STRETCHER TRAFFIC IN AMBULATORY
CARE FACILITIES
GROUP I-2 IN AREAS WHERE REQUIRED FOR BED MOVEMENT
OCCUPANCY
OCC.
B
S-1
LOAD
WATER CLOSETS
M W
1.8 1.8
0.06 0.06
M W
LAVATORIES
M W
1.125 1.125
0.06 0.06
DRINKING
FOUNTAINS
0.9
0.012
OTHER
1 SERVICE SINK
REQUIRED 1.86 1.86 1.185 1.185 0.912 1 SERVICE SINK
PROVIDED 2 2 2 2 2 1 SERVICE SINK
LIFE SAFETY SYMBOL LEGEND
ROOM NAME
Oc
2000 SF
# Oc
LF OCCUPANT LOAD FACTOR
OCCUPANCY TYPE
ROOM AREA
OCCUPANT LOAD
TD - XX'-XX"
CPT - XX'-XX"
EXIT ACCESS TRAVEL DISTANCE (APPROXIMATE)
COMMON PATH OF TRAVEL (APPROXIMATE)
LOCATION OF MAX. PATH OF TRAVEL
LOCATION OF COMMON PATH OF TRAVEL
REQ'D
W
PROV'D
W
32" 34"
EXIT 1
EXIT CAPACITY PROVIDED
OCCUPANT LOAD AT EXIT COMPONENT
EXIT COMPONENT DESIGNATION
EXIT CAPACITY USED
EXIT DISCHARGE100
E - 100
TOTAL OCCUPANTS
OCCUPANCY TYPE SUBTOTALS
NON-RATED
NON-RATED SMOKE-RESISTANT
1 HR FIRE-RESISTANT
1 HR FIRE-RESISTANT / SMOKE BARRIER
2 HR FIRE-RESISTANT
2 HR FIRE-RESISTANT / SMOKE BARRIER
3 HR FIRE-RESISTANT
4 HR FIRE-RESISTANT
FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER AND CABINET
EXIT SIGN
COPYRIGHT © 2025 HUITT-ZOLLARS, INC.
PROJECT NO.:
REVIEWED BY:
ISSUES / REVISIONS LOG:
DRAWN BY:
APPROVED BY:
PROJECT ADDRESS:
CONSULTANTS:
PROFESSIONAL SEALS:
OWNER:
PROJECT:
ARCHITECT / ENGINEER:
SHEET TITLE:
SHEET NUMBER:
1001 Fannin Street Suite 4040
Houston, TX 77002
(713) 622-1180 www.huitt-zollars.com
1 2 3 4 5 6
1 2 3 4 5 6
E
D
C
B
A
HUITT-ZOLLARS, INC.
FIRM REGISTRATION NO. F-761
HCFCD PROJECT ID NO.
Z100-00-00-X360
/9
/2
4:
:5
PM
C :\U se rs
\h ar re ol a\ D oc um en ts
\H C
FC
D
_M
TS
C _D is tri bu tio n C en te r_
AR
C H
_R
_h ar re ol aX
6X .rv t
HCFCD MTSC -
Distribution Center
10700 VINE CREST DR,
HOUSTON TX 77086
LS-101
LIFE SAFETY PLANS
R313332.19
LTH
LW
Approver
OCCUPANT LOAD CALCULATIONS
NO. ROOM NAME AREA OCCUPANCY OCCUPANT LOAD
FACTOR
OCCUPANT
LOAD
LEVEL 1
106 WELLNESS 70.72 SF B 150 1
105 ELEC. 40.19 SF ACC 300 1
104 ELEC 42.29 SF ACC 300 1
102 JAN. 40.54 SF ACC 300 1
101 OFFICE 111.23 SF B 150 1
110 LOCKER 502.14 SF LCKS 50 11
100 VESTIBULE 406.24 SF B 150 3
112 WAREHOUSE 4476.86 SF S-1 500 9
113 HYDROLOGY
STORAGE 600SF 585.4 SF S-1 500 2
114 SURVEY STORAGE
300SF 300.11 SF S-1 500 1
LEVEL 2
201 BREAK RM. 446.51 SF AUC 15 21
213 STOR. 92.87 SF ACC 300 1
204 PHONE BOOTH 57.97 SF B 150 1
206 I.T. 67.79 SF ACC 300 1
208 ALERT ROOM 1092.3 SF B 150 8
210 OFFICE 127.93 SF B 150 1
211 FILE STOR. 127.61 SF B 150 1
214 OFFICE 112.01 SF B 150 1
215 OFFICE 112.01 SF B 150 1
216 OFFICE 107.48 SF B 150 1
207 CONF. 315.75 SF B 150 3
217 OPEN OFFICE 2827.12 SF B 150 19
218 OFFICE 159.12 SF B 150 1
219 ALERT COMMAND 159.3 SF B 150 1
220 IT SUPPORT 150.76 SF B 150 1
212 I.T. STOR. 98 SF ACC 300 1
TOTAL OCCUPANTS 94
1/8" = 1'-0"
LIFE SAFETY PLAN - LEVEL 1A3
1/8" = 1'-0"
LIFE SAFETY PLAN - LEVEL 2C3
THE BUILDING SHALL COMPLY WITH APPLICABLE BUILDING CODES. SELECT CALCULATIONS AND KEY REQUIREMENTS ARE INCLUDED BELOW BY IBC CHAPTER. SPECIFIC CONSTRUCTION REQUIREMENTS
AND CRITERIA ARE CONTAINED IN OTHER SHEETS.
PROJECT SUMMARY
FIRST FLOOR RENNOVATION AND EXPANSION OF SECOND FLOOR.
APPROX. GROSS SQUARE FOOTAGE:
FIRST FLOOR: 7,500 SF
SECOND FLOOR: 7,288 SF
NUMBER OF STORIES: 2
APPROX. BLDG. HEIGHT: 32'-6" TO TOP OF PARAPET
GROUP OCCUPANCIES: B (PRIMARY USE); S-1 (SECONDARY USE)
CONSTRUCTION TYPE: II-B, NOT SPRINKLERED
BUILDING CODE ANALYSIS
a.
b.
c.
d.
e.
a.
b.
c.
d.
e.
f.
CHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION
PRIMARY USE - BUSINESS AREAS
B, BUSINESS (IBC 304.1)
SECONDARY USE - WAREHOUSE STORAGE AND DISTRIBUTION
S-1, MODERATE-HAZARD STORAGE (IBC 311.2)
CHAPTER 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
N/A
CHAPTER 5 - GENERAL BUILDING HEIGHTS AND AREAS
504 BUILDING HEIGHT AND STORIES
TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
TABLE 506.2 ALLOWABLE AREA FACTOR IN SQUARE FEET
508 MIXED USE AND OCCUPANCY
TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
S = BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN
ACCORDANCE WITH SECTION 903.1.1.
NS = BUILDINGS NOT EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED
IN ACCORDANCE WITH SECTION 903.1.1.
N = NO SEPARATION REQUIREMENT.
NP = NOT PERMITTED.
SEE SECTION 420.
THE REQUIRED SEPARATION FROM AREAS USED ONLY FOR PRIVATE OR PLEASURE VEHICLES
SHALL BE REDUCED BY 1 HOUR BUT NOT TO LESS THAN 1 HOUR.
SEE SECTION 406.3.4.
SEPARATION IS NOT REQUIRED BETWEEN OCCUPANCIES OF THE SAME CLASSIFICATION.
SEE SECTION 422.2 FOR AMBULATORY CARE FACILITIES.
NO SEPARATION OF OCCUPANCY REQUIRED FOR B OR S-1 OCCUPANCY GROUPS.
CHAPTER 6 - TYPES OF CONSTRUCTION
601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
N/A N/A
IN ALL OCCUPANCIES, HEAVY TIMBER SHALL BE ALLOWED WHERE A 1-HOUR OR LESS FIRE-
RESISTANCE RATING IS REQUIRED.
NOT LESS THAN THE FIRE-RESISTANCE RATING REQUIRED BY OTHER SECTIONS OF THIS CODE.
NOT LESS THAN THE FIRE-RESISTANCE RATING BASED ON FIRE SEPARATION DISTANCE (SEE TABLE 602).
NOT LESS THAN FIRE-RESISTANCE RATING AS REFERENCED IN SECTION 704.10.
TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE
SEPARATION DISTANCE
ALL EXTERIOR WALLS ARE AT LEAST 10'-0" FROM THE NEAREST STRUCTURE.
a.
b.
c.
a.
b.
c.
CHAPTER 7 - FIRE AND SMOKE PROTECTION FEATURES
705 EXTERIOR WALLS
705.8.1 ALLOWABLE AREA OF OPENINGS
THE MAXIMUM AREA OF UNPROTECTED AND PROTECTED OPENINGS PERMITTED IN AN EXTERIOR
WALL IN ANY STORY OF A BUILDING SHALL NOT EXCEED THE PERCENTAGES SPECIFIED IN TABLE 705.8.
EXCEPTION 2: BUILDINGS WHOSE EXTERIOR BEARING WALLS, EXTERIOR NONBEARING WALLS AND EXTERIOR PRIMARY STRUCTURAL FRAME ARE NOT REQUIRED TO BE FIRE-RESISTANCE RATED SHALL
BE PERMITTED TO HAVE UNLIMITED UNPROTECTED OPENINGS.
706 FIRE WALLS - NONE
707 FIRE BARRIERS - NONE
707 FIRE PARTITIONS - NONE
CHAPTER 8 - INTERIOR FINISHES
803 WALL AND CEILING FINISHES
803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED FOR WAINSCOTTING OR
PANELING OF NOT MORE THAN 1,000 SQUARE FEET OF APPLIED SURFACE AREA IN THE GRADE
LOBBY WHERE APPLIED DIRECTLY TO A NONCOMBUSTIBLE BASE OR OVER FURRING STRIPS
APPLIED TO A NONCOMBUSTICLE BASE AND FIREBLOCKED AS REQUIRED BY SECTION
803.1.3.1.
N/A
REQUIREMENTS FOR ROOMS AND ENCLOSED SPACES SHALL BE BASED ON SPACES
ENCLOSED BY PARTITIONS. WHERE A FIRE-RESISTANCE RATING IS REQUIRED FOR
STRUCTURAL ELEMENTS, THE ENCLOSING PARTITIONS SHALL EXTEND FROM THE FLOOR TO
THE CEILING. PARITIONS THAT DO NOT COMPLY WITH THIS SHALL BE CONSIDERED TO BE
ENCLOSING SPACES AND THE ROOMS OR SPACES ON BOTH SIDES SHALL BE CONSIDERED TO
BE ONE ROOM OR SPACE. IN DETERMINING THE APPLICABLE REQUIREMENTS FOR ROOMS
AND ENCLOSED SPACES, THE SPECIFIC OCCUPANCY THEREOF SHALL BE THE GOVERNING
FACTOR REGARDLESS OF THE GROUP CLASSIFICATION OF THE BUILDING OR STRUCTURE.
INTERIOR FINISHES SHALL BE DESIGNED TO MORE RESTRICTIVE B OCCUPANCY GROUP
REQUIREMENTS. REFER TO MATERIAL FINISH SCHEDULE FOR INDIVIDUAL MATERIAL
CLASSIFICATIONS.
CHAPTER 9 - FIRE PROTECTION SYSTEMS
903 AUTOMATIC SPRINKLER SYSTEMS - NOT PROVIDED
906 PORTABLE FIRE EXTINGUISHERS
906.3 FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
FOR SI: 1 FOOT = 304.8 MM, 1 SQUARE FOOT = 0.0929 M2, 1 GALLON = 3.785 L.
TWO 2 1/2-GALLON WATER-TYPE EXTINGUISHERS SHALL BE DEEMED THE EQUIVALENT OF ONE
4-A RATED EXTINGUISHER.
ANNEX E3.3 OF NFPA 10 PROVIDES MORE DETAILS CONCERNING APPLICATION OF THE
MAXIMUM FLOOR AREA CRITERIA.
TWO WATER-TYPE EXTINGUISHERS EACH WITH A 1-A RATING SHALL BE DEEMED THE
EQUIVALENT OF ONE 2-A RATED EXTINGUISHER FOR LOW HAZARD OCCUPANCIES.
EXTINGUISHERS SHALL BE PROVIDED ACCORDING TO TABLE 906.3. REFER TO LIFE SAFETY SHEETS
FOR LOCATIONS.
CHAPTER 10 - MEANS OF EGRESS
1001 OCCUPANT LOAD
REFER TO LIFE SAFETY PLAN AND OCCUPANT LOAD CALCULATIONS.
OCCUPANT LOAD:
FIRST FLOOR: 31
SECOND FLOOR: 63
TOTAL: 94
1005 MEANS OF EGRESS SIZING
1005.3.1 STAIRWAYS
0.3 INCHES PER OCCUPANT X 64 OCCUPANTS = 18.9"
REQUIRED COMBINED EXIT WIDTH: 18.9"
PROVIDED COMBINED EXIT WIDTH: 70"
1005.3.2 OTHER EGRESS COMPONENTS
0.2 INCHES PER OCCUPANT X 94 OCCUPANTS = 18.8 INCHES
REQUIRED COMBINED EXIT WIDTH: 18.8"
PROVIDED COMBINED EXIT WIDTH: 170.0"
1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
PERMITTED COMMON PATH OF TRAVEL: 75'-0"
MAXIMUM COMMON PATH OF TRAVEL PROVIDED: 39'-4"
TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
MINIMUM NUMBER OF EXITS PER STORY: 2 EXITS
PROVIDED NUMBER OF EXITS PER STORY: 2 EXITS
1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE
PERMITTED EXIT ACCESS TRAVEL DISTANCE: 200'-0"
MAX. PROVIDED EXIT ACCESS TRAVEL DISTANCE: 175'-0"
1020 CORRIDORS
TABLE 1020.2 MINIMUM CORRIDOR WIDTH
CORRIDORS SHALL BE 44 INCHES WIDE.
1020.4 DEAD ENDS
MAXIMUM DEAD END PERMITTED: 20'-0"
MAXIMUM DEAD END PROVIDED: NONE
CHAPTER 29 - PLUMBING SYSTEMS
2902.1 MINIMUM NUMBER OF FIXTURES
B OCCUPANCY:
WATER CLOSETS: 1 PER 25 OCCUPANTS FOR THE FIRST 50 OCCUPANTS & 1 PER 50 FOR THE
REMAINDER EXCEEDING 50
LAVATORIES: 1 PER 40 OCCUPANTS FOR THE FIRST 80 OCCUPANTS & 1 PER 80 FOR THE
REMAINDER EXCEEDING 80
DRINKING FOUNTAINS: 1 PER 100 OCCUPANTS
OTHER: 1 SERVICE SINK
S-1 OCCUPANCY:
WATER CLOSETS: 1 PER 100 OCCUPANTS
LAVATORIES: 1 PER 100 OCCUPANTS
DRINKING FOUNTAINS: 1 PER 1,000 OCCUPANTS
OTHER: 1 SERVICE SINK
MARK DATE DESCRIPTION
1 04/18/25 DD COORDINATION
2 06/16/25 50% CD
3 07/28/25 95% CD
4 08/28/25 ISSUE FOR PERMIT & BID
N
E
O
A L
I G
EN
S
O S I N
E
F
R E
A
S
X F T E
P R
T
S
A T E
O
NSE
D
ECI
L
FRED DALLY
90904
COPYRIGHT © 2025 HUITT-ZOLLARS, INC.
PROJECT NO.:
REVIEWED BY:
ISSUES / REVISIONS LOG:
DRAWN BY:
APPROVED BY:
PROJECT ADDRESS:
CONSULTANTS:
PROFESSIONAL SEALS:
OWNER:
PROJECT:
ARCHITECT / ENGINEER:
SHEET TITLE:
SHEET NUMBER:
1001 Fannin Street Suite 4040
Houston, TX 77002
(713) 622-1180 www.huitt-zollars.com
1 2 3 4 5 6
1 2 3 4 5 6
E
D
C
B
A
PROJECT # : 25-017-00
12/09/2025 BID-READY SET
HCFCD PROJECT ID NO.
Z100-00-00-X360
12/09/2025
08/27/2025 100%CD
/8
/2
:3
:2
A
M
C U s e rs \M a ra l\ O n e D ri v e
D a lly
A s s o c ia te s In c \D o c u m e n ts
\2 -0
-0
H
C F
C D
M T
S C n d f lo o r a d d it io n
R m s a if z a d e h .r v t
HCFCD MTSC -
Distribution Center
10700 VINE CREST DR,
HOUSTON TX 77086
S001
3D VIEW AND SHEET
LIST
R313332.19
MS
LM
FD
PRESENTATION 3D VIEW
SHEET LIST
Sheet Number Sheet Name
S001 3D VIEW AND SHEET LIST
S101 GENERAL STRUCTURAL CRITERIA
S201 FOUNDATION PLAN
S202 SECOND FLOOR FRAMING PLAN
S203 ROOF FRAMING PLAN
S401 TYPICAL FOUNDATION DETAILS
S501 TYPICAL FRAMING DETAILS
S502 TYPICAL COMPOSITE FRAMING DETAILS
S503 FLOOR FRAMING DETAILS
S504 FRAMING DETAILS
S601 PANEL ELEVATIONS
MARK DATE DESCRIPTION
10 65(*)
1. INTERNATIONAL BUILDING CODE, 2021 EDITION.
2. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE); MINIMUM DESIGN LOADS FOR
BUILDINGS AND OTHER STRUCTURES, ASCE 7-16, AS AMENDED.
3. AMERICAN CONCRETE INSTITUTE (ACI), BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE, ACI 318, AS AMENDED.
4. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL
CONSTRUCTION, 15TH EDITION (ASD),AS AMENDED.
5. AMERICAN WELDING SOCIETY (AWS).
6. STEEL JOIST INSTITUTE (SJI), STANDARD SPECIFICATIONS FOR OPEN WEB STEEL
JOISTS AND JOIST GIRDERS.
7. STEEL DECK INSTITUTE (SDI), DESIGN MANUAL FOR COMPOSITE DECKS, FORM
DECKS, ROOF DECKS, AND CELLULAR METAL FLOOR DECK WITH ELECTRICAL
DISTRIBUTION.
8. AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF
COLD FORMED STEEL STRUCTURAL MEMBERS", LATEST EDITION.
SUPERIMPOSED LOADS ARE GIVEN IN POUNDS PER SQUARE FOOT (PSF).
BUILDING AREA
C. GRAVITY LOADS:
LIVE LOAD
(PSF)
DEAD LOAD
(PSF)
B. BUILDING CODES AND DESIGN STANDARDS:
THE STRUCTURE AS SHOWN HAS BEEN DESIGNED IN ACCORDANCE WITH THE
BUILDING CODE REQUIREMENTS AND DESIGN STANDARDS TO SUPPORT THE FINAL
BUILDING SERVICE LOADS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING ADDITIONAL SUPPORTS FOR THE STRUCTURE IF NECESSITATED BY THE
CONSTRUCTION SEQUENCE OR METHODS OF FABRICATION, HANDLING, ERECTION,
AND OTHER CONSTRUCTION OPERATIONS.
A. DESIGN CONCEPT:
10010
1. STRUCTURAL CONCEPT, STANDARDS AND LOADS
1. SLAB ON GRADE
2. OFFICE
3. ELEVATOR LOBBY
4. ELEVATED FLOOR CORRIDORS 100104. STAIRS
*INCLUDES AN ALLOWANCE OF 15 PSF FOR PARTITION WEIGHT
20205. ROOF
1. WIND LOADS FOR AN BASIC DESIGN WIND SPEED OF 145 MPH (ASD WIND
SPEED OF 112 MPH), 3-SECOND GUST, WITH EXPOSURE C AND A RISK
CATEGORY IV (ASCE 7-16 METHOD)
2. COMPONENTS AND CLADDING PRESSURES (PSF) FOR "CLOSED" BUILDINGS:
a. RE: IBC 2021 FOR ADDITIONAL DESCRIPTION OF PRESSURE ZONES.
b. POSITIVE PRESSURES ARE PRESSURES ACTING TOWARD THE BUILDING.
c. NEGATIVE PRESSURES ARE PRESSURES ACTING AWAY FROM THE BUILDING.
d. VALUES ABOVE ARE FOR BASIC DESIGN WIND PRESSURES. THE ASD FACTOR 0.6.
e. ZONE WIDTH DIMENSIONS:
a (walls) = 5'-0"
0.2h = 5'-7"
0.6h = 16'-10"
10 FT2 21.3
ROOF
3. WIND-BORNE DEBRIS REGION, USE RISK CATEGORY IV WIND SPEED
OF 145 MPH BASIC (112 MPH ASD)
0.6h 0.6h
0.
2h
2 21'
5 5 a a a a
WALL
ZONE 1
100 FT2
-83.3
16.8 -65.0
21.3
ZONE 1'
-47.8
16.8 -47.8
21.3
ZONE 2
-109.8
16.8 -86.4
21.3
ZONE 3
-149.7
16.8 -102.8
10 FT2 47.8
WALLS
ZONE 4
100 FT2
-51.8
40.8 -44.8
47.8
ZONE 5
-63.8
40.8 -40.8
ROOF
F. GROUND SNOW LOADS: 5 PSF
G: SPECIAL LOADS:
1. STAIR TREADS, RAILING AND GUARDRAILS:
ITEM REQUIRED CAPACITY
TREADS
TOP RAILS
OTHER RAILS, FILLERS &
CONNECTIONS
HAND RAILS
300 POUNDS AT CENTER
50 PLF HORIZONTALLY (DISTRIBUTED)
50 PSF HORIZONTALLY (DISTRIBUTED)
200 POUNDS ANY DIRECTION
2. PIPE LOADS WITH WATER:
SIZE WEIGHT MAX. SPACING OF HANGERS
4" DIA. 17 PLF 10'-0"
6" DIA. 32 PLF 10'-0"
8" DIA. 50 PLF 10'-0"
10" DIA. 75 PLF 5'-0"
12" DIA. 102 PLF 5'-0"
VALUES ASSUME SCHEDULE 40 STEEL PIPE
A. CONSTRUCTION METHODS, PROCEDURES AND SEQUENCES ARE THE RESPONSIBILITY
OF THE CONTRACTOR AND THE CONTRACTOR SHALL TAKE ALL THE NECESSARY MEANS
TO MAINTAIN AND PROTECT THE STRUCTURAL INTEGRITY OF ALL CONSTRUCTION AT ALL
STAGES.
B. THESE NOTES APPLY TO STRUCTURAL DOCUMENTS SEALED BY THE STRUCTURAL
ENGINEER AND ARE INTENDED TO BE COMPLEMENTARY TO AND USED IN CONJUNCTION
WITH THE PLANS AND SPECIFICATIONS, INCLUDING THOSE PREPARED BY OTHER
DISCIPLINES. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE
ARCHITECT/STRUCTURAL ENGINEER IMMEDIATELY. ANY SUCH DISCREPANCIES SHALL BE
RESOLVED TO THE MORE STRINGENT REQUIREMENTS, UNLESS OTHERWISE AUTHORIZED
BY THE STRUCTURAL ENGINEER.
C. ANY DISCREPANCIES ON THE STRUCTURAL DOCUMENTS SHALL BE IMMEDIATELY
BROUGHT TO THE ATTENTION OF THE ARCHITECT/STRUCTURAL ENGINEER PRIOR TO
SUBMISSION OF BIDS OR PROPOSALS, OR IF NOT REASONABLE DISCERNABLE DURING
PREPARATION OF BIDS AND PROPOSALS, BEFORE COMMENCING THE WORK IN
QUESTIONS. NO FIELD CHANGES OR DIVIATIONS FROM THE DESIGN ARE TO BE MADE
WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT AND/OR STRUCTURAL
ENGINEER. NO CHANGE ORDER CONSIDERATION WILL BE GIVEN TO CHANGES FOR WHICH
THE ARCHITECT AND/OR ENGINEER WERE NOT CONTACTED PRIOR TO CONSTRUCTION OF
THE AFFECTED ITEM.
D. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONSTRUCTION, INCLUDING
EXISTING WORK, PRIOR TO COMMENCING WORK. ANY DISCREPANCIES SHALL BE REPORT
IMMEDIATELY TO THE ARCHITECT/STRUCTURAL ENGINEER.
E. ALL PROPOSED SUBSTITUTIONS MUST BE EQUAL OR BETTER AND SHALL BE REVIEWED
BY THE ARCHITECT/ENGINEER PRIOR TO ANY PERTINENT WORK AND PRIOR TO THE
AWARD OF THE CONTRACT.
F. NOT ALL OPENINGS AND OTHER COMPONENTS THAT ARE REQUIRED HAVE BEEN
SHOWN IN THE STRUCTURAL DRAWINGS. COORDINATE WITH THE ARCHITECTURAL,
MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND VERIFY THE LOCATIONS AND
SIZES OF ALL CHASES, INSERTS, OPENINGS, SLEEVES, FINISHES, DEPRESSIONS, PADS
AND OTHER PROJECT REQUIREMENTS. FLOOR PLAN WILL BE FURNISHED FOR THAT
PURPOSE.
G. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE MECHANICAL, ELECTRICAL,
PLUMBING AND ARCHITECTURAL DRAWINGS TO DETERMINE WHERE OPENINGS ARE
REQUIRED IN REINFORCED CONCRETE BEAMS, SLABS AND WALLS.
H. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, DETAILING ALL THE OPENINGS,
INCLUDING ADDED REINFORCEMENT AS SHOWN ON THE TYPICAL WALL, SLAB AND BEAM
OPENING DETAILS FOR REVIEW.
I. ADDITIONAL REINFORCEMENT ABOVE THAT SHOWN IN THE TYPICAL SLAB AND BEAM
OPENING DETAILS MAY BE REQUIRED AND WILL BE REVIEWED ON THE SHOP DRAWINGS.
J. USE THE MANUFACTURER'S CERTIFIED DRAWINGS AND SPECIFICATIONS FOR THE
EQUIPMENT ANCHORAGE AND DETAILS.
K. ALL CONSTRUCTION JOINTS SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE
INCORPORATED INTO THE STRUCTURE. ADDITIONAL CONSTRUCTION JOINTS TO
FACILITATE CONSTRUCTION SHALL BE LOCATED AND DETAILED ON THE SHOP DRAWINGS
FOR REVIEW.
L. HORIZONTAL CONSTRUCTION JOINTS SHALL NOT BE PERMITTED IN BEAMS UNLESS
SHOWN ON THE STRUCTURAL DRAWINGS.
M. ALL CONSTRUCTION AND CONTROL JOINTS FOR BEAMS WHICH ARE EXPOSED TO VIEW
ARE TO BE LOCATED TO COINCIDE WITH THE ARCHITECTURAL RUSTICATION JOINTS AS
SHOWN ON THE BUILDING ELEVATION SHEETS OR AS REVIEWED IN WRITING.
N. SHOP DRAWINGS
2. GENERAL NOTES FOR CONSTRUCTION
1. THE TERM "SHOP DRAWINGS" INCLUDES FABRICATION, MANUFACTURING,
ERECTION AND SETTING DRAWINGS, BROCHURES, CERTIFICATES, AND
PRODUCT DATA DESCRIBING MATERIALS AND EQUIPMENT. SHOP DRAWINGS
SHALL INCLUDE ALL PERTINENT INFORMATION REQUIRED FOR THE ENGINEER
TO FULLY EVALUATE THE MATERIALS BEING REPRESENTED BY THE SUBMITTAL
INCLUDING THE PHYSICAL PROPERTIES, DIMENSIONS, LOCATIONS AND
METHOD OF INSTALLATION.
2. SHOP DRAWINGS WILL BEAR THE REVIEW STAMP OF THE CONTRACTOR
INDICATING THAT HE HAS REVIEWED THE DRAWINGS FOR CONFORMANCE
WITH THE CONTRACT DOCUMENTS; COORDINATED ITEMS INCLUDED IN THE
SUBMITTAL WITH RELATED ITEMS; AND VERIFIED AND COORDINATED
DIMENSIONS.
3. REPRODUCTIONS OF THE ENGINEERING DRAWINGS WILL NOT BE
ACCEPTABLE AS SHOP DRAWINGS.
4. ANY SHOP DRAWING NOT CONFORMING TO THESE REQUIREMENTS WILL BE
CAUSE FOR REJECTION AND WILL BE RETURNED WITHOUT ANY FURTHER
ACTION.
BAR SIZE
GRADE 60
#8 #9
#10 #11
#7
#4 #5
#3
#6
3000/3500 50004000 40003000/3500 5000 6000
Ld FOR TOP BARS
28 DAY CYLINDER
CONCRETE STRENGTH (PSI)
Ld FOR BOTTOM BARS
NORMAL WEIGHT
BUILDING COMPONENT
3000 4000
28 DAY CYLINDER COMPRESSIVE STRENGTH
POUNDS PER SQUARE INCH(PSI)
A. CONCRETE SCHEDULE:
SLUMP
(IN)
MAX
AGGREGATE
SIZE (IN)
W/C RATIO
3. CONCRETE
28 DAY CYLINDER
CONCRETE STRENGTH (PSI)
B. PROVIDE DEFORMED NEW BILLET STEEL BARS CONFORMING TO ASTM A615, GRADE 60. ALL
REINFORCING STEEL SHALL BE SECURELY HELD IN PLACE; PROVIDE ADDITIONAL BARS OR STIRRUPS FOR
SUPPORT AS REQUIRED.
C. WELDED WIRE FABRIC SHALL CONSIST OF FLAT SHEETS AND SHALL CONFORM TO ASTM A185, WITH A
MINIMUM YIELD STRENGTH OF 65.0 KSI
D. PROVIDE FULL EMBEDMENT WITH STANDARD 90 DEGREE HOOKS FOR ALL DOWELS. IF NOT OTHERWISE
SPECIFIED, THE DOWEL SIZE AND SPACING SHALL BE THE SAME AS THE MAIN REINFORCING.
E. WHEN REINFORCING STEEL IN GRADE BEAMS, WALLS, SLABS AND BEAMS, IS NOTED AS CONTINUOUS, SPLICE REINFORCING STEEL ONLY WHEN UNAVOIDABLE DUE TO STOCK LENGTHS. STAGGER ALL SPLICES
A MINIMUM OF 4'-0". ADJACENT BAR SPLICES ARE NOT ACCEPTABLE.
LOCATE THE TOP BAR SPLICES WITHIN THE MIDDLE HALF OF THE SPAN AND LOCATE THE BOTTOM BAR SPLICES AT SUPPORTS OR BETWEEN SUPPORTS AND 1/3 SPAN POINT, UNLESS NOTED OTHERWISE ON
PLANS, DETAILS OR SCHEDULES.
F. PROVIDE INTERIOR AND EXTERIOR HORIZONTAL LAPPED CORNER BARS AT ALL CORNERS TO MATCH
THE SIZE, TYPE AND SPACING OF THE WALL AND GRADE BEAM HORIZONTAL REINFORCING.
G. UNLESS SPECIFICALLY NOTED, SCHEDULED OR DETAILED OTHERWISE, PROVIDE DEVELOPMENT LENGTH FOR REINFORCING IN CONCRETE COMPONENTS IN ACCORDANCE WITH THE SCHEDULE IN NOTE H. BELOW. THIS SCHEDULE SHALL APPLY TO ALL DEVELOPMENT LENGTHS NOT OTHERWISE NOTED, DETAILED OR SCHEDULED IN THE DRAWINGS OR SPECIFICATIONS.
H. REINFORCING BAR DEVELOPMENT LENGTHS (Ld) IN INCHES FOR VARIOUS CONCRETE STRENGTHS IN POUNDS PER SQUARE INCH (PSI). TOP BARS ARE DEFINED AS HORIZONTAL REINFORCING SO PLACED IN A MEMBER THAT MORE THAN 12 INCHES OF CONCRETE IS CAST BELOW THE BAR. ALL OTHER CONDITIONS
ARE CONSIDERED BOTTOM BARS FOR DEVELOPMENT AND SPLICE LENGTH PURPOSES.
1. WHEN TWO BARS OF DIFFERENT SIZES ARE LAPPED, THE SMALLER SIZE SHALL
GOVERN THE LAP LENGTH UNLESS SPECIFICALLY NOTED.
2. WELDED OR MECHANICAL SPLICES CAPABLE OF DEVELOPING 125% OF THE
BAR YIELD STRENGTH MAY BE USED IN LIEU OF THE LAPS. SUCH SPLICES MAY BE
EITHER FULL BUTT WELDS OR SERIES "C CADWELDS OR EQUAL."
J. AT LAP SPLICES, PROVIDE LAP SPLICE LENGTHS FOR REINFORCING BARS 1.3 TIMES
THE Ld SHOWN IN TABLE IN NOTE H ABOVE.
K. THE GENERAL NOTES, LAP LENGTHS OR DETAILS PERTAINING TO REINFORCING STEEL
AS SHOWN ON THE DETAIL SHEETS OR OTHER SCHEDULES SHALL SUPERSEDE THE
NOTES SHOWN ON THIS SHEET.
L. PROVIDE THE FOLLOWING COVER FOR CAST-IN-PLACE CONCRETE REINFORCING.
1. UNFORMED SURFACES IN CONTACT WITH EARTH: 3 INCHES
2. UNFORMED SURFACES OVER MOISTURE BARRIER: 2 INCHES
3. FORMED SURFACES EXPOSED TO EARTH OR WEATHER
a. #6 AND LARGER: 2 INCHES
b. #5 AND SMALLER: 1 1/2" INCHES
4. FORMED SURFACES NOT EXPOSED TO EARTH OR
WEATHER
a. SLABS AND WALLS: 3/4 INCHES
b. BEAMS AND COLUMNS 1 1/2 INCHES
1. SLAB-ON-GRADE
2. SLAB-ON-DECK
4-61" 0.50
4-61" 0.50
3. ALL OTHER CONCRETE 4-61" 0.52
4. FOOTING 5-71 1/2" 0.55
4. EXCAVATION, BACKFILLING & FOUNDATIONS
A. A GEOTECHNICAL EXPLORATION OF SUBSURFACE CONDITIONS, CONTAINING TEST
BORINGS, LABORATORY TEST, ENGINEERING ANALYSIS AND FOUNDATION
RECOMMENDATIONS, IS NOT AVAILABLE FOR REVIEW.
B. MAINTAIN PROPER SITE DRAINAGE DURING CONSTRUCTION SO
THAT PONDING OF WATER DOES NOT OCCUR IN THE BUILDING AREA.
C. INSTALL SLAB ON GRADE OVER 15 MIL VAPOR BARRIER
A. ROLLED SHAPES:
B. CONNECTIONS
D. HEADED SHEAR CONNECTORS
5. STRUCTURAL STEEL
1. ALL STRUCTURAL STEEL FOR ALL THE HORIZONTAL FRAMING MEMBER SHALL CONFORM
TO ASTM A992, GRADE 50, UNLESS OTHERWISE NOTED
2. ALL STRUCTURAL STEEL FOR HOLLOW STRUCTURAL SECTIONS SHALL CONFORM TO ASTM
A500, GRADE B WITH A MINIMUM YIELD OF 46 KSI, UNLESS OTHERWISE NOTED.
3. ALL STRUCTURAL STEEL FOR PIPE SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B, UNLESS OTHERWISE NOTED.
4. ALL STRUCTURAL STEEL FOR ANGLES, PLATES AND MISCELLANEOUS STEEL SHALL
CONFORM TO ASTM A36, UNLESS OTHERWISE NOTED.
5. ALL EXPOSED STEEL TO BE GALVANIZED.
1. THE DESIGN OF STRUCTURAL STEEL CONNECTIONS IS THE RESPONSIBILITY OF THE
CONTRACTOR AND THE STEEL FABRICATOR. THE DESIGN OF THE CONNECTION SHALL BE
PERFORMED BY A REGISTERED PROFESSIONAL ENGINEER EMPLOYED BY THE STEEL FABRICATOR.
THE DETAILS AND CALCULATIONS SHALL INCLUDE, BUT NOT LIMITED TO, THE FOLLOWING:
A. ALL WELD SIZES AND LENGTHS
B. ALL BOLT SIZES, LOCATIONS, QUANTITIES AND GRADES
C. ALL PLATE AND ANGLE SIZES, THICKNESS AND DIMENSIONS
D. ALL WORK POINT LOCATIONS AND RELATED INFORMATION
2. PROVIDE STANDARD BOLTED CONNECTIONS CONFORMING TO AISC BOLTED CONNECTIONS,
USING ASTM A325 OR A490 BOLTS, FOR THE BEAM END SHEARS INDICATED IN THE DOCUMENTS.
PROVIDE MINIMUM OF TWO BOLTS FOR ALL CONNECTIONS.
3. ALL WELDED CONNECTIONS SHALL CONFORM TO AWS UNLESS OTHERWISE NOTED.
4. SURVEY ALL PLANS, DETAILS, SECTIONS, SCHEDULES AND SPECIFICATIONS FOR SPECIAL
CONNECTIONS.
5. UNLESS OTHERWISE NOTED AND/OR SPECIFIED, ALL BEAM CONNECTIONS SHALL BE DESIGNED
TO SUPPORT 1/2 THE TOTAL UNIFORM LOAD FOR THE APPLICABLE MEMBER SIZE AND SPAN AS
DETERMINED BY THE TABLES FOR ALLOWABLE UNIFORM LOADS ON BEAM IN THE 15TH EDITION OF
THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION MANUAL OF STEEL CONSTRUCTION (ASD)
6. WHERE BEAMS ARE TO RECEIVE HEADED SHEAR CONNECTORS, DESIGN THOSE BEAM
CONNECTIONS FOR THE REACTION SHOWN. IF REACTIONS ARE NOT SHOWN, DESIGN THE
CONNECTIONS TO SUPPORT 40 PERCENT OF THE MAXIMUM WEB SHEAR, V, FOR THE APPLICABLE
MEMBER SIZE AS DETERMINED BY THE TABLES FOR ALLOWABLE UNIFORM LOADS ON BEAMS IN
THE 15TH EDITION OF THE AISC MANUAL
7. MOMENT CONNECTIONS SHOWN SHALL BE DESIGNED TO FULLY DEVELOP THE SECTION IN
FLEXURE AND TO SUPPORT 1/2 THE TOTAL UNIFORM LOAD FOR SHEAR AS DESCRIBED IN NOTE 5
ABOVE.
8. WHERE FILLET WELD IS NOT SHOWN ON DETAIL, ITS SIZE SHALL BE ASSUMED TO BE THE PLATE
THICKNESS OF THE THINNEST PIECE MINUS 1/16"
1. ALL HEADED SHEAR CONNECTORS SHALL BE 3/4 IN. DIAMETER STUDS x 4 IN. LONG AFTER
W…