This document is an Invitation to Bid (ITB) for the construction of Security Vestibules at five elementary schools in Pulaski County, Virginia. The project includes the installation of new security vestibules within two existing elementary schools - Critzer Elementary School and Snowville Elementary School. The scope of work involves demolition and new construction activities. The ITB was issued on January 18, 2024, with a bid submission deadline of January 18, 2024. The project is classified as a Construction Type IIB Occupancy, with Critzer Elementary not fully sprinklered and Snowville Elementary not fully sprinklered per NFPA 13. The maximum travel distances, interior finish requirements, and occupancy load summaries are provided in the document.
The ITB specifies that the successful bidder must comply with various codes and regulations, including the 2018 Virginia Construction Code, 2018 Virginia Existing Building Code, and the 2010 ADA Standards for Accessible Design. Pricing terms, set-asides, incumbent information, and funding details are not provided in the document. The ITB requires the contractor to coordinate with the owner and other trades to ensure a successful project completion.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 17102 Project Manual Issued for Bids 01 18 24.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT DESCRIPTION:
PROJECT INCLUDES THE INSTALLATION OF NEW SECURITY VESTIBULES WITHIN TWO
EXISTING ELEMENTARY SCHOOLS IN PULASKI COUNTY, VIRGINIA.
CODES & REGULATIONS
2018 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF THE VIRGINIA UNIFORM
STATEWIDE BUILDING CODE (VUSBC),
2018 VIRGINIA EXISTING BUILDING CODE (VEBC)
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
ICC/ANSI A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
KENTUCKY
TENNESSEE
NORTH CAROLINA
VIRGINIA
WEST
VIRGINIA
WASHINGTON
D.C.
NASHVILLE
FRANKFORT
CHARLESTON
RICHMOND
RALEIGHKNOXVILLE
CHATTANOOGA
ASHEVILLE
CHARLOTTE
ROANOKE
BLUEFIELD
TAZEWELL
ABINGDON
BRISTOL
BIG STONE GAP
HARLAN
NORTON
RICHLANDS
GRUNDY
PRINCETON
LEXINGTON
N
SECURITY VESTIBULES FOR
PULASKI AND HIWASSEE VIRGINIA
PULASKI COUNTY PUBLIC SCHOOLS
PREPARED FOR
SNOWVILLE
ELEMENTARY
SCHOOL
PROJECT LOCATION
FOR ELECTRICAL ONLYFOR ARCHITECTURAL &
LIFE SAFETY ONLY
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
VICINITY MAP
726 Auburn Avenue
Radford, Virginia 24141
P: (540) 633-1897
F: (540) 633-1896 www.T-L.com
EST. 1956 LOCATION MAP
/1
/2
:4
:1
P M
C U s e rs
\k a th ry n fo s te r\ D o c u m e n ts
\1
C ri tz e r, S n o w v ill e S e c u ri ty
V e s ti b u le s v k fo s te rW N
B
B .r v t
G001
T
IT
L E
S H
E E
T
S E
C U
R
IT
Y V
E S
T
IB
U L E
S F
O R
C R
IT
Z
E R
S
N O
W V
IL
L E
E L E
M E
N T
A R
Y S
C H
O O
L S
17102
01/18/2024
PROJECT NO.: 17102
01/18/2024
ISSUED FOR BID
KCF
EFS
EFS
CRITZER & SNOWVILLE ELEMENTARY SCHOOLS
CRITZER
ELEMENTARY
SCHOOL
SHEET INDEX
SHEET NAME SHEET NUMBER
GENERAL
TITLE SHEET G001
PROJECT INFORMATION AND DATA G002
ARCHITECTURAL
CRITZER ELEMENTARY SCHOOL DEMOLITION & NEW WORK PLANS A101
CRITZER ELEMENTRY SCHOOL REFLECTED CEILING PLAN & INTERIOR ELEVATIONS A102
SNOWVILLE ELEMENTARY SCHOOL DEMOLITION & NEW WORK PLANS A103
SNOWVILLE ELEMENTARY REFLECTED CEILING PLAN & INTERIOR ELEVATIONS A104
DOOR AND FINISH SCHEDULES, NOTES, AND LEGEND A601
STOREFRONT ELEVATIONS A602
ELECTRICAL
ELECTRICAL LEGEND, GENERAL NOTES, ABBREVIATIONS AND DETAIL E001
CRITZER ELEMENTARY SCHOOL DEMOLITION & NEW WORK PLANS E101
CRITZER ELEMENTRY SCHOOL LIGHTING PLAN E102
SNOWVILLE ELEMENTARY SCHOOL DEMOLITION & NEW WORK PLANS E103
SNOWVILLE ELEMENTARY SCHOOL LIGHTING PLAN E104
100 CRITZER DRIVE
PULASKI, VA 24301
4858 LEAD MINE ROAD
HIWASSEE, VA 24347
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
01/18/2024
BUILDING AREA SUMMARY
CRITZER ELEMENTARY
EXISTING BUILDING AREA:
RENOVATION AREA:
82,350 SF
843 FT
SNOWVILLE ELEMENTARY
EXISTING BUILDING AREA:
RENOVATION AREA:
38,845 SF
963 FT
CODES & REGULATIONS
2018 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF THE VIRGINIA UNIFORM
STATEWIDE BUILDING CODE (VUSBC),
2018 VIRGINIA EXISTING BUILDING CODE (VEBC)
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
ICC/ANSI A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
FIRE-RESISTANCE RATING
REQUIREMENTS
BUILDING ELEMENT
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS (HOURS)
FIRE RATING
(EXCERPT FROM VUSBC TABLE 601, UON)
BEARING WALLS
EXTERIOR
INTERIOR
0 HR
0 HR
CONSTRUCTION TYPE: IIB
PRIMARY STRUCTURAL FRAME 0 HR
NONBEARING WALLS & PARTITIONS
EXTERIOR (VUSBC TABLE 602) 0 HR
NONBEARING WALLS & PARTITIONS
INTERIOR 0 HR
FLOOR CONSTRUCTION & SECONDARY MEMBERS 0 HR
ROOF CONSTRUCTION & SECONDARY MEMBERS 0 HR
BUILDING ELEMENT FIRE RATING
MISCELLANEOUS FIRE-RESISTANCE RATING REQUIREMENTS
CORRIDORS (VUSBC TABLE 1020.1) 1 HR *
* 1 HOUR REQUIRED AT CRITZER AND SNOWVILLE ELEMENTARY
GENERAL INFORMATION
SECURITY VESTIBULES AT FIVE ELEMENTARY SCHOOLS IN PULASKI COUNTY, VA
SCOPE:
CONSTRUCTION CLASSIFICATION:
CONSTRUCTION TYPE: IIB
OCCUPANCY:
DESCRIPTION: EDUCATION
OCCUPANCY CLASSIFICATION: E
CRITZER ELEMENTARY IS NOT FULLY SPRINKLERED PER NFPA 13
SNOWVILLE ELEMENTARY IS NOT FULLY SPRINKLERED PER NFPA 13
CRITZER AND SNOWVILLE ELEMENTARY MAXIMUM
TRAVEL DISTANCES:
COMMON PATH OF TRAVEL (VUSBC 1006.2.1):
EXIT ACCESS TRAVEL DISTANCE (VUSBC
TABLE 1017.2):
DEAD ENDS (VUSBC 1020.4):
75 FT MAX
200 FT MAX
20 FT MAX
INTERIOR FINISH REQUIREMENTS:
CORRIDOR WALLS & CEILINGS (VUSBC TABLE 803.13):
-CLASS B
FLOORS (VUSBC 804.4.2):
-CLASS II
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
ROOM & ENCLOSED SPACE WALLS & CEILINGS (VUSBC TABLE 803.13):
-CLASS C
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
CRITICAL RADIANT FLUX NOT LESS THAN 0.22 WATTS/CM
ASBESTOS CONTAINING MATERIALS AND/OR PAINTS CONTAINING LEAD SHALL
NOT BE USED IN ANY FORM ON THE PROJECT.
EXIT ENCLOSURES & EXIT PASSAGEWAYS (VUSBC TABLE 803.13):
-CLASS A
FLAME SPREAD INDEX 26-75
SMOKE-DEVELOPED INDEX 0-450
OCCUPANCY LOAD SUMMARY
CALCULATED PER VUSBC TABLE 1004.1.2 (SEE EXCERPT BELOW) OR ACTUAL NUMBER
OF OCCUPANTS SCHEDULED, WHICHEVER IS GREATER.
NOTE: EXISTING OCCUPANT LOAD DOES NOT CHANGE WITH RENOVATIONS.
A101A
CONSTRUCTION NOTE DESIGNATION
TOILET & BATH ACCESSORY DESIGNATION
A101
ROOM NAME
PARTITION TYPE DESIGNATION
NEW CONSTRUCTION
EXISTING CONSTRUCTION
EXISTING TO BE DEMOLISHED
DOOR/OPENING NUMBER DESIGNATION
ROOM NUMBER DESIGNATION
FLOOR LEVEL
SUFFIX AT MULTIPLE
DOOR/OPENING LOCATIONS
DOOR/OPENING NUMBER
BUILDING AREA
ROOM NUMBER
BUILDING AREA
FLOOR LEVEL
DEMOLITION NOTE DESIGNATION
E00 WINDOW TYPE DESIGNATION
(E=EXTERIOR / I=INTERIOR)
1 REVISION NUMBER DESIGNATION
A101A101
1 SIM
SECTION CUT DESIGNATION
(DETAIL DESIGNATION SIMILAR)
NUMBER INDICATES
SECTION OR DETAIL
SHEET NUMBER WHERE
SECTION OR DETAIL IS
DRAWN
SHEET NUMBER WHERE
SECTION OR DETAIL IS
TAKEN
ELEVATION DESIGNATION
SIM A101
A101
SIM1
A101
A101
NUMBER INDICATES ELEVATION
SHEET NUMBER WHERE
ELEVATION IS TAKEN
SHEET NUMBER WHERE
ELEVATION IS DRAWN
INTERIOR
ELEVATION
EXTERIOR
ELEVATION
MATCHLINE
0'-0"
SPOT ELEVATION
00 COLUMN LINE/HEAD
DATUM LINE
LEVEL
0'-0"
AREA 'A'
KEY PLAN AREA
ARCHITECTURAL LEGEND
XX-00
OPENING FRAME DESIGNATION
NUMBER
MATERIAL
PLAN NORTH
NORTH ARROW
(REFER TO CIVIL PLAN SHEETS FOR TRUE NORTH WHEN
APPLICABLE TO THE PROJECT)
AREA 'B'
A101, A102...
ADDITIONAL
SHEET
REFERENCES
GENERAL CONSTRUCTION NOTES:
1. ALL WORK SHALL BE PERFORMED IN OBSERVANCE OF LOCAL, STATE, AND FEDERAL CODES
AND REGULATIONS.
2. EXISTING CONDITIONS SHOWN HEREIN WERE TAKEN FROM SITE OBSERVATIONS AND
COMPLETE OR PARTIAL SETS OF ORIGINAL DESIGN DRAWINGS WHEN MADE AVAILABLE. ANY
DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL BUILT CONDITIONS ARE TO BE
REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
3. LOOSE FURNISHINGS, APPLIANCES, AND EQUIPMENT ARE NOT INCLUDED WITHIN THIS
PROJECT'S SCOPE (NIC), UNLESS OTHERWISE NOTED.
4. DO NOT "SCALE" DRAWINGS. USE DIMENSIONAL INFORMATION PROVIDED ONLY. FOR
DIMENSIONS NOT SHOWN OR IN QUESTION, CONTRACTOR SHALL REQUEST CLARIFICATION
FROM ARCHITECT PRIOR TO PROCEEDING.
5. ALL DIMENSIONS ARE MEASURED TO FACE OF GWB OR MASONRY CONSTRUCTION UNLESS
OTHERWISE NOTED.
6. ALL DIMENSIONS NOTED AS "CLEAR," ARE FROM FACE OF FINISH TO FACE OF FINISH.
7. PROVIDE CONCEALED WOOD BLOCKING AT LOCATIONS OF WALL-MOUNTED EQUIPMENT,
CASEWORK, SHELVING.
8. ALL DOORS LOCATED IN STUD PARTITIONS ARE TO BE LOCATED 4" FROM AN ADJACENT WALL
TO THE BACK OF THE FRAME OR CENTERED BETWEEN 2 ADJACENT WALLS UNLESS
OTHERWISE NOTED.
9. ALL DOORS LOCATED IN MASONRY CONSTRUCTION ARE TO BE LOCATED 8" FROM AN
ADJACENT WALL OR CENTERED BETWEEN 2 ADJACENT WALLS UNLESS OTHERWISE NOTED.
10. PROVIDE MINIMUM 1'-6" CLEAR ON PULL SIDE OF DOORS BETWEEN JAMB AND
INTERSECTING WALL ON LATCH SIDE OF DOOR. PROVIDE 1'-0" CLEAR ON PUSH SIDE OF DOOR
BETWEEN JAMB AND INTERSECTING WALL ON LATCH SIDE OF DOOR FOR ALL DOORS WITH
BOTH A LATCH AND A CLOSER.
CONCRETE
MASONRY UNIT
CONCRETE
STONE VENEER
FACE BRICK
GYPSUM WALLBOARD
METAL/WOOD STUD
INSULATION - BATT
INSULATION - RIGID
STEEL
CAVITY DRAINAGE
MATERIAL
FINISH CARPENTRY
EARTH
GRAVEL
PLYWOOD
GROUT
INSULATION - SPRAY
ROUGH CARPENTRY
BLOCKING
ALUMINUM
MATERIAL LEGEND
GENERAL DEMOLITION NOTES:
1. ANY DISCREPANCIES BETWEEN ITEMS NOTED FOR DEMOLITION AND ACTUAL FIELD CONDITIONS
ARE TO BE REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF DEMOLITION.
2. DO NOT REMOVE OR DEMOLISH ANY LOAD-BEARING BUILDING ELEMENTS WITHOUT FIRST
CONTACTING THE ARCHITECT/STRUCTURAL ENGINEER.
3. REMOVE AND/OR CAP OFF ANY MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS
CONTAINED WITHIN CONSTRUCTION SCHEDULED TO BE REMOVED. CAP OFF BEHIND FACE OF
EXISTING WALLS INDICATED TO REMAIN OR BELOW THE FLOOR SLAB. COORDINATE THESE
REQUIREMENTS WITH MECHANICAL, PLUMBING, AND ELECTRICAL REQUIREMENTS. REFER ALSO
TO CUT AND PATCH REQUIREMENTS IN THE PROJECT MANUAL.
4. LEGALLY DISPOSE OF ALL MATERIALS ASSOCIATED WITH SELECTIVE DEMOLITION WORK UNLESS
OTHERWISE NOTED TO BE PROVIDED TO OWNER OR SALVAGED FOR REUSE.
5. COORDINATE ANY REQUIRED TEMPORARY UTILITY OR SERVICE SHUT-OFF WITH OWNER AND
OTHER REQUIREMENTS FOUND IN THE CONTRACT DOCUMENTS.
6. PERFORM DEMOLITION WORK IN SUCH A WAY AS TO MINIMIZE DISTURBANCES WITHIN THE
EXISTING FACILITY.
7. WHERE NEW UTILITIES OR SERVICES ARE RUN ABOVE CEILINGS IN AREAS OF THE EXISTING
FACILITY, REMOVE ONLY AS MUCH EXISTING CEILING SYSTEM AS REQUIRED FOR INSTALLATION.
REINSTALL REMOVED CEILING SYSTEM ONCE ABOVE CEILING WORK IS COMPLETE. REPLACE
CEILING PANELS AND/OR GRID DAMAGED BY SELECTIVE DEMOLITION WORK.
8. SALVAGE ALL EXISTING FINISH HARDWARE FROM DEMOLISHED DOORS & FRAMES. TURN
SALVAGED HARDWARE OVER TO OWNER.
9. NOTE CENTERED WITHIN A GIVEN SPACE: THIS IMPLIES THAT THE NOTED CONSTRUCTION IS TO
BE REMOVED FROM FLOOR TO CEILING ON ALL WALLS TO REMAIN IN THE ORIGINAL SPACE.
10. NOTE WITH LEADER: THIS IMPLIES THAT A PATCH/PORTION OF THE NOTED CONSTRUCTION IS
TO BE REMOVED WITHIN THE FIELD OF THE INDICATED WALL.
11. NOTE WITHIN DIMENSION STRING: THIS IMPLIES THAT THE NOTED CONSTRUCTION IS TO BE
REMOVED FROM FLOOR TO CEILING FOR THE INDICATED PORTION OF WALL.
OFFICEOFFICEOFFICE
CORRIDOR
CORRIDOR
NEW OFFICE
C103
NEW RESOURCE
OFFICER OFFICE
C104
VESTIBULE
C101
LOBBY
C102
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
LIFE SAFETY LEGEND
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
01/18/2024
/1
/2
:4
:1
P M
C
U se rs \k a th ry n fo st e r\ D o cu m e n ts
\1
C ri tz e r, S n o w v ill e S e cu ri ty
V e st ib u le s v k fo st e rW
N
B B
.r v t
G002
P R
O
JE
C T
I N
F O
R M
A T
IO
N
A N
D D
A T
A
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
KCF
EFS
EFS
17102
01/18/2024
PLAN NORTH
1/8" = 1'-0"
CRITZER ELEMENTARY LIFE SAFETY PARTIAL PLAN
N o
D a te
P u rp o se o f D o cu m e n t
Is su
VESTIBULE
C101
CORRIDOR
LOBBY
C102
OFFICE OFFICE OFFICE
NEW OFFICE
C103
NEW RESOURCE
OFFICER OFFICE
C104
AI PHONE
C103
C104
C103A
4'-11 3/4" ± 20'-3 7/8"
C102
/8
1' -8
/4
SF
C
HM-5
A1
A1
SF
C
A601A101
A102
A101 1 2
A102
A101 3A102
A101
SI
M
22'-5 5/8" 10'-4 1/4"
SF
C
C101
6 6
A101
A102
OFFICE OFFICE OFFICE
CORRIDOR
LOBBY
VESTIBULE
CORRIDOR
CLASSROOM
9'-6" 3'-4" 6'-2" 3'-4"
0"
5"
6 5
CRITZER ELEMENTARY CONSTRUCTION NOTES:
1. THRU-WALL TRANSACTION DRAWER BY CREATIVE INDUSTRIES, INC MODEL 2725-SS OR EQUAL.
2. EXISTING BRICK CONTROL JOINT.
3. NEW RECEPTION DESK.
4. TOOTH-IN SALVAGED BRICK AT NEW OPENING.
5. PROVIDE VCT AND RUBBER BASE. REFER TO FINISH SCHEDULE.
6. PARTITION BELOW. REFER TO SECTION SHEET A102.
#OCCURS WHERE ARE INDICATED ON DRAWINGS.
CRITZER ELEMENTARY DEMOLITION NOTES:
1. REMOVE EXISTING MASONRY WALL FOR NEW OPENING. SALVAGE EXISTING MASONRY FOR NEW WORK.
EXISTING BEARING TO REMAIN. SHORE AS REQUIRED.
2. REMOVE EXISTING DOOR(S) AND FRAME.
3. REMOVE EXISTING STOREFRONT IN ITS ENTIRETY.
4. REMOVE EXISTING CEILING HEATER. REINSTALL IN NEW CEILING. REFER TO NEW WORK FLOOR PLAN.
5. RELOCATE SPEAKER PER OWNER DIRECTION.
6. REMOVE PROJECTION SCREEN AND MONITOR. TURN OVER TO OWNER.
7. REMOVE EXISTING VCT AND RUBBER BASE. PREP FLOOR FOR NEW FINISHES.
?OCCURS WHERE ARE INDICATED ON DRAWINGS.
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
01/18/2024
/1
/2
:4
:1
P M
C
U se rs \k a th ry n fo st e r\ D o cu m e n ts
\1
C ri tz e r, S n o w v ill e S e cu ri ty
V e st ib u le s v k fo st e rW
N
B B
.r v t
A101
C R
IT
Z
E R
E
LE
M E
N T
A R
Y S
C H
O O
L
D E
M O
LI
T
IO
N
N
E W
W O
R K
P
LA
N S
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
KCF
EFS
EFS
17102
01/18/2024
PLAN NORTH
1/4" = 1'-0"
CRITZER ELEMENTARY NEW WORK FLOOR PLAN
PLAN NORTH
1/4" = 1'-0"
CRITZER ELEMENTARY DEMOLTION FLOOR PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN
N o
D a te
P u rp o se o f D o cu m e n t
Is
C1
C101
C102
C103
C104
C7
C7
C7
10'-0"
10'-0"
10'-0"
10'-0"
C3
C4
C5
C8
C8
C4
C6
BASE AS SCHEDULEDGWB, PAINT
SOLID SURFACE
COUNTERTOP
6"3
6"
1/2" REVEAL
1 1/2" REVEAL
6"
6'-0" 2'-0"
8'-0"
SOLID SURFACE
COUNTERTOP
PLASTIC LAMINATE
BASE CABINET
OPEN
BASE AS SCHEDULED
GWB, PAINT
COUNTERTOP
BRACKET, PAINT 3
6"
4'-0"
8'-0"
BASE AS SCHEDULED
COUNTERTOP
BRACKET, PAINT
SOLID SURFACE
COUNTERTOP
PLASTIC LAMINATE
BASE CABINET
6"3
6"
GWB, PAINT
OPEN
2'-0" 6'-0"
4'-0"
A102A102
A102A102
REFLECTED CEILING LEGEND:
LAY-IN LIGHT
SURFACED MOUNTED LIGHT
AIR DEVICES-SUPPLY
SPEAKER
AIR DEVICES-EXHAUST
EXIT SIGN
CRITZER ELEMENTARY
REFLECTED CEILING NOTES:
C1 NEW 2x2 ACT.
C2 NOT USED.
C3 EXISTING HEATER TO REMAIN.
C4 ADJUST DUCTWORK. RELOCATED DIFFUSER IN C104
C5 RELOCATE SPEAKER.
C6 PROVIDE FIRE DAMPER IN NEW DUCTWORK. PROVIDE
LINTEL SIMILAR TO 2A601.
C7 EXISTING ACT TO REMAIN.
C8 ADJUST EXISTING CEILING GRID/TILE FOR NEW
PARTITION TO EXTEND TO THE STRUCTURE ABOVE.
PROVIDE NEW GRID ANGLES.
#OCCURS WHERE ARE INDICATED ON DRAWINGS.
6"
6"
2'-0"
1'-0"
PLASTIC LAMINATE
BASE CABINET
SOLID SURFACE
COUNTERTOP
5/8" GWB
3 5/8" METAL STUD AT
16" ON CENTER
RUBBER BASE
RUBBER BASE
6"
1'-6 1/8"
1'-0"
6"
COUNTERTOP
BRACKET, PAINT
SOLID SURFACE
COUNTERTOP
5/8" GWB
3 5/8" METAL STUD AT
16" ON CENTER
RUBBER BASE
8"
EQUAL EQUAL
NEW ALUMNIUM 3 DIMENSIONAL
LETTERINHG MOUNTED TO THE
EXISITNG PRECAST PANEL. LETTERS TO
BE 14" HIGH, CENTER TEXT IN PANEL.
OWNER TO SELECT COLOR
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
12/15/2023
/1
/2
:4
:1
P M
C
U se rs \k a th ry n fo st e r\ D o cu m e n ts
\1
C ri tz e r, S n o w v ill e S e cu ri ty
V e st ib u le s v k fo st e rW
N
B B
.r v t
A102
C R
IT
Z
E R
E
LE
M E
N T
R Y
S C
H O
O L
R E
F
LE
C T
E D
C E
IL
IN
G P
LA
N
I
N T
E R
IO
R
E
LE
V A
T
IO
N S
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
KCF
EFS
EFS
17102
01/18/2024
PLAN NORTH
1/4" = 1'-0"
CRITZER ELEMENTARY REFLECTED CEILING PLAN
SCALE: 3/8" = 1'-0"A101 A102
3 INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"A101 A102
2 INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"A101 A102
1 INTERIOR ELEVATION
KEY PLAN
SCALE: 1/8" = 1'-0"
4' 8'0 16'
SCALE: 1/4" = 1'-0"
2' 4'0 8'
SCALE: 3/8" = 1'-0"
6" 1'0 2'
SCALE: 3/4" = 1'-0"A102 A102
4 SECTION
SCALE: 3/4" = 1'-0"A102 A102
6 SECTION
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
SCALE: 1/4" = 1'-0"A101 A102
5 EXTERIOR ELEVATION
VESTIBULE
S102
LOBBY
S103
CORRIDOR
AI PHONE
NEW RESOURCE
OFFICER OFFICE
S105
NEW OFFICE
S104
S102A
S101
S101A
S102
A2
A1
A1
12'-0"
0"
SF S2
SF S5
SF
S
SF S8
SF
S
SF S4
11'-6" ± 12'-0"
S103
H M
-6
7'-11 7/8" ± 8'-4 1/4"
A104
A103
S104
A602A103
S105
S104A
VESTIBULE
S101
5'
-2
/4
0"
A2135.00°
2'-0" 4'-5 3/4" 5'-0 1/2"
3/
4"
9'-0 1/8"
2"
0"
1" 3'-8"
A2
A2
SF S3
/4
A1
4'-6 5/8" 7'-0"
SNOWVILLE ELEMENTARY CONSTRUCTION NOTES:
1. THRU-WALL TRANSACTION DRAWER. RECESSED IN COUNTERTOP. CREATIVE INDUSTRIES, INC
DEAL DRAWER MODEL 1622 OR EQUAL.
2. ALIGN FINISHES.
3. PROVIDE NEW BULLNOSE BLOCK WHERE WALL HAS BEEN REMOVED.
4. INFILL EXISTING RECESS TO ALIGN WITH EXISTING FLOOR.
#OCCURS WHERE ARE INDICATED ON DRAWINGS.
SNOWVILLE ELEMENTARY DEMOLITION NOTES:
1. REMOVE PORTION OF EXISTING WALL FOR NEW OPENING.
2. REMOVE EXISTING HM FRAME. METAL FRAME TO REMAIN FOR NEW STOREFRONT.
3. REMOVE RECESSED FLOOR MAT.
?OCCURS WHERE ARE INDICATED ON DRAWINGS.
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
01/18/2024
/1
/2
:4
:1
P M
C
U se rs \k a th ry n fo st e r\ D o cu m e n ts
\1
C ri tz e r, S n o w v ill e S e cu ri ty
V e st ib u le s v k fo st e rW
N
B B
.r v t
A103
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O L
D E
M O
LI
T
IO
N
N
E W
W O
R K
P
LA
N S
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
KCF
EFS
EFS
17102
01/18/2024
PLAN NORTH
1/4" = 1'-0"
SNOWVILLE ELEMENTARY NEW WORK FLOOR PLAN
PLAN NORTH
1/4" = 1'-0"
SNOWVILLE ELEMENTARY DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN
N o
D a te
P u rp o se o f D o cu m e n t
Is
S
C1
C1
C1
C1
C1
C1
S102
S104 S103
S105
S101
C4 C4
C4
C3
C5
3'-0" 1'-4"
OPEN
BASE AS
SCHEDULED
SOLID SURFACE
COUNTERTOP
PLASTIC LAMINATE
BASE CABINET
ALUMINUM
STOREFRONT
5/8" GWB OVER 3
5/8" METAL STUDS
THRU-WALL
TRANSACTION DRAWER
BRACKET, PAINT2
0"
7'-2"
11'-6"
A602A103
6'-0" 1'-4" FILLER
7'-7 1/8"
BASE AS SCHEDULED
GWB, PAINT
SOLID SURFACE
COUNTERTOP
PLASTIC LAMINATE
BASE CABINET
ALUMINUM
STOREFRONT
5/8" GWB OVER 3
5/8" METAL STUDS
THRU-WALL
TRANSACTION DRAWER
BRACKET, PAINT
EQEQ
0" 3
8"
SPEAK-THRU
SNOWVILLE ELEMENTARY
REFLECTED CEILING NOTES:
C1 EXISTING ACT TO REMAIN.
C2 EXISTING BULKHEAD TO REMAIN.
C3 ADJUST EXISTING CEILING GRID/TILE FOR NEW PARTITION TO EXTEND TO THE
STRUCTURE ABOVE. PROVIDE NEW GRID ANGLES.
C4 EXISTING CEILING TO REMAIN.
C5 ADJUST DUCTWORK. RELOCATE DIFFUSER IN S105.
#OCCURS WHERE ARE INDICATED ON DRAWINGS.
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
LIFE SAFETY LEGEND
VESTIBULE
S102
LOBBY
S103
NEW OFFICE
S104
NEW RESOURCE
OFFICER OFFICE
S105
CORRIDOR
REFLECTED CEILING LEGEND:
LAY-IN LIGHT
SURFACED MOUNTED LIGHT
AIR DEVICES-SUPPLY
SPEAKER
AIR DEVICES-EXHAUST
EXIT SIGN
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
12/15/2023
/1
/2
:4
:1
P M
C
U se rs \k a th ry n fo st e r\ D o cu m e n ts
\1
C ri tz e r, S n o w v ill e S e cu ri ty
V e st ib u le s v k fo st e rW
N
B B
.r v t
A104
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
R E
F
LE
C T
E D
C E
IL
IN
G
P
LA
N
I N
T E
R
IO
R E
LE
V
A T
IO
N
S
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
KCF
EFS
EFS
17102
01/18/2024
PLAN NORTH
1/4" = 1'-0"
SNOWVILLE ELEMENTARY REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"
4' 8'0 16'
KEY PLAN
SCALE: 3/8" = 1'-0"A103 A104
1 INTERIOR ELEVATION
SCALE: 3/8" = 1'-0"A103 A104
2 INTERIOR ELEVATION
PLAN NORTH
1/8" = 1'-0"
SNOWVILLE ELEMENTARY LIFE SAFETY PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
SCALE: 3/8" = 1'-0"
6" 1'0 2'
N o
D a te
P u rp o se o f D o cu m e n t
Is
GENERAL DOOR NOTES:
1. PROVIDE CONTINUOUS BEAD OF SEALANT AT PERIMETER OF EACH
SIDE OF OPENING FRAME. COORDINATE SEALANT TYPE WITH SEALANT
SCHEDULED IN SPECIFICATIONS.
2. PROVIDE DOORS WITH A 3/4" UNDERCUT (UON).
3. INSTALL GLAZED OPENINGS WITH REMOVABLE GLAZING STOP ON SIDE
OPPOSITE PUBLIC OCCUPIED AREAS UNLESS OTHERWISE INDICATED.
4. REFER TO SPECIFICATION SECTION 087100 - "DOOR HARDWARE" FOR
HARDWARE SETS.
DOOR SCHEDULE NOTES:
1. NEW STOREFRONT TO BE INSTALLED AT EXISTING METAL FRAMING.
DOOR SCHEDULE LEGEND
HM HOLLOW METAL
GHM GALVANIZED HOLLOW METAL
STL STEEL OVERHEAD COILING DOOR
A CLAD ALUMINUM-CLAD WOOD
SHM SECURITY HOLLOW METAL DOOR
IG-1 1" INSULATED LOW-E GLASS
G-1 1/4" TEMPERED FLOAT GLASS
MANUF PER MANUFACTURER
WD WOOD
SF ALUMINUM STOREFRONT
N
NOTE: REFER TO DOOR SCHEDULE FOR DOOR MATERIAL REQUIREMENTS.
PER SCHED
P
ER
S C
H
ED
U
LE
7"
100 SQ IN MAXFG
PER SCHED
P
ER
S C
H
ED
U
LE
HG
PER SCHED
P
ER
S C
H
ED
U
LE
P
ER
S C
H
ED
U
LE
2"
2"
PER
SCHED 2"
HM-1 HM-2
2" 2'-6"2"
PER
SCHED 2"
2"
0" 2"
P
ER
S C
H
ED
U
LE
2"
2"
PER
SCHED
2"
2'-2"
2"
2'-2" 2"
HM-3
P
ER
S C
H
ED
U
LE
2"
4"
8"
2"
P
ER
S C
H
ED
U
LE
4"
2"
PER
SCHED 2"
HM-4
G-3 G-4 G-4
HM-5 HM-6
S105
G-1
C104
NON-RATED PARTITIONA
TYPE
A1
STUD
SIZE
3-5/8"
PART
THICK
4-7/8"
SOUND
ATTN
BLANKET
3"
SUBSTRATE ON
EXPOSED FACE
ONLY
6" M
IN
P
ER
F
IN
IS
H S
C H
ED
U
LE
FIN FLR
UNDERSIDE OF
DECK/STRUCTURE
DEFLECTION TRACK
FIN CEILING, REFER TO
FINISH SCHEDULE
SOUND ATTENUATION
BLANKET (SEE SCHEDULE
BELOW)
1-LAYER OF 5/8" GWB EA
SIDE
ACOUSTICAL SEALANT
MTL STUD AT 1'-4" OC
(SEE SCHEDULE BELOW)
TYPE
A2
STUD
SIZE
3 5/8"
PART
THICK
5 3/8""
SOUND
ATTN
BLANKET
SUBSTRATE ON
EXPOSED FACE
ONLY
FIN FLR
5/8" GWB EACH SIDE
(ABUSE RESISTANT)
3 5/8" 20 GAUGE, METAL
STUDS AT 16" ON CENTER
1/2" BALLISTIC FIBERGLASS,
PROVIDE 4" WIDE BALLISTIC
BATTEN AT EACH
FIBERGLASS JOINT
OPEN OFFICELOBBY
. 1
0' -1
0" V
A R
IE
S
EXISTING CEILING
GWB CAP
GENERAL PARTITION NOTES:
1. REFER TO LIFE SAFETY DRAWINGS FOR LOCATION OF FIRE-
RATED/SMOKE PARTITIONS AND BARRIERS.
2. ALL INTERIOR PARTITIONS ARE PARTITION TYPE 'A1' (UON).
3. REFER TO STRUCT DWGS TO CONFIRM LOCATIONS THAT REQUIRE A
FOUNDATION OR THICKENED SLAB.
4. PROVIDE GROUT AND VERTICAL REINFORCEMENT AT CMU
PARTITION TYPES AS REQUIRED BY STRUCT DWGS.
5. INSTALL 20-GA FRAMING IN LIEU OF 25-GA FRAMING AT ALL
LOCATIONS SCHEDULED FOR CERAMIC WALL TILE INSTALLATION.
REFER TO FINISH SCHEDULE THIS SHEET FOR LOCATIONS.
6. AT ALL SPACES SCHEDULED TO RECEIVE TILE WAINSCOT, PROVIDE
5/8-INCH TILE BACKER BOARD TO EXTENT OF TILE IN LIEU OF 5/8-
INCH TYPE 'X' GWB. PROVIDE MOISTURE- AND MOLD-RESISTANT
GWB FOR REMAINING HEIGHT OF WALL.
7. EXTEND GWB AND FURRING (WHERE APPLICABLE) TO UNDERSIDE
OF DECK IN SPACES NOT SCHEDULED TO RECEIVE FINISH CEILING.
REFER TO FINISH SCHEDULE THIS SHEET FOR LOCATIONS.
8. ALL STUDS AND FURRING USED FOR NON-STRUCTURAL INTERIOR
PARTITIONS ARE TO BE 25 GA (UON). REFER TO STRUCTURAL DWGS
FOR STRUCTURAL STUD REQUIREMENTS.
9. ALL METAL STUDS AT DOOR JAMBS AND BEHIND WALL-MOUNTED
SINKS ARE TO BE 20 GA.
10. PROVIDE 5/8-INCH MOISTURE- AND MOLD-RESISTANT GWB IN LIEU
OF STANDARD GWB AT JANITOR'S CLOSETS, LAVATORY SPACES,
TLT/SHOWER SPACES, LOCKER ROOMS AND OTHER WET WALLS.
FINISH SCHEDULE LEGEND
PNT PAINTED FINISH (REFER TO PARTITION TYPES FOR SUBSTRATE)
ACT ACOUSTIC CEILING TILE
RUBBER 4-INCH RUBBER WALLBASE
GENERAL FINISH NOTES:
1. TRANSITION BETWEEN DIFFERENT FLOOR FINISH MATERIALS OR COLORS
SHALL BE PROVIDED UNDER CENTERLINE OF DOORS UNLESS OTHERWISE
NOTED.
2. PAINT ALL HOLLOW METAL DOORS AND FRAMES, METAL STAIRS, STEEL PIPE
HANDRAILS/GUARDRAILS, AND ALL OTHER MISCELLANEOUS FERROUS METALS
WITHIN EACH SPACE.
3. PROVIDE MOISTURE- AND MOLD-RESISTANT GYPSUM CEILINGS IN LIEU OF
STANDARD GYPSUM CEILINGS AT ALL LAVATORY, TOILET, AND SHOWER
AREAS.
4. REFER TO REFLECTED CEILING PLAN ON A801 FOR CEILING HEIGHTS
SCHEDULED AS "VARIES".
FINISH NOTES:
1. PROVIDE RUBBER BASE AT NEW WALLS (BOTH SIDES) TO MATCH EXISTING.
REMOVE AND REINSTALL
CMU/BRICK AS REQUIRED
FOR NEW LINTEL
NEW STOREFRONT
EXISTING WALL
6"x6"x5/16" STEEL
LINTEL, PAINT
3 1/2"x3 1/2"x5/16"
LLV STEEL ANGLE
SEALANT JOINT
AT PERIMETER
EACH SIDE
SOLID SURFACE COUNTERTOP
6" 4"
2'-9"
COUNTERTOP BRACKET, PAINT
HEADER
5/8" GWB
3 5/8" METAL STUDS
EXISTING STRUCTURE
2"
5/8" GWB EACH SIDE
(ABUSE RESISTANT)
3 5/8" 20 GAUGE, METAL
STUDS AT 16" ON CENTER
1/2" BALLISTIC FIBERGLASS,
PROVIDE 4" WIDE
BALLISTIC BATTEN AT EACH
FIBERGLASS JOINT
5/8" GWB
3 5/8"METAL STUDS
AT 16" ON CENTER
SEALANT
SHIM SPACE
STOREFRONT
5/8" GWB
3 5/8"METAL STUDS
AT 16" ON CENTER
SEALANT
SHIM SPACE
STOREFRONT
6"x6"x5/16" STEEL
ANGLE, PAINT - MIN 8"
BEARING EACH SIDE
EXISTING WALL
GROUT SOLID
EXISTING WALL
SOLID SURFACE SILL
ALUMINUM SILL
3"
TOOTH-IN SALVAGED BRICK
NEW CMU,
GROUT SOLID
EXISTING WALL
SEALANT
THERMALLY BROKEN
ALUMINUM
STOREFRONT
EXISTING
MASONRY
VIF
1"
SOLID
SURFACE
SILL
SEALANT
1"
2"
0"
2"
4"
0"
G-2
SPEAK-
THRU
8"
2"
3'-4"
2"3'-0"2"
A602A601
4'-2" ±
2" 3'-10" 2"
2"
0"
2"
4"
2"
0"
0"
G-2
G-2
A601A601
A601A601
8"
SIM
SIM
TYPE
REFER TO PLAN
FOR PARTITION
SEALANT JOINT AT
PERIMETER EA SIDE
METAL STUD HEADER
PROVIDE MIN 3 JAMB
ANCHORS EA SIDE
SEALANT JOINT AT
PERIMETER EA SIDE
STUDS AT JAMBS EA SIDE.
EXTEND FULL HEIGHT OF
STRUCTURE
TY
P
E
R
EF
ER
T
O P
LA
N
FO
R
P A
R
TI
TI
O
N
DOOR SCHEDULE
MARK
OPENING SIZE DOOR FRAME DETAILS
REMARKS
NO OF
LEAFS WIDTH HEIGHT MATERIAL THICKNESS TYPE
RATING
(MIN) GLAZING HDW SET NO TYPE MATERIAL HEAD JAMB
C101 2 6'-0" 7'-0" ALUM 1 3/4" FG IG-1 1 SF C1 ALUM * * * NOTE 1
C102 2 6'-0" 7'-0" ALUM 1 3/4" FG G-1 1 SF C1 ALUM 3A601
C103 1 3'-0" 7'-0" WOOD 1 3/4" HG 20 MIIN G-2 3 HM-4 HM 8A601 10A601
C103A 1 3'-0" 7'-0" WOOD 1 3/4" HG 20 MIIN G-2 2 HM-4 HM 2A601 5A601
C104 1 3'-0" 7'-0" WOOD 1 3/4" HG G-1 4 HM-2 HM 11A601 12A601
S101 2 6'-0" 7'-0" ALUM 1 3/4" FG IG-1 1 SF S6 ALUM * * * NOTE 1
S101A 2 6'-0" 7'-0" ALUM 1 3/4" FG G-1 7 SF S5 ALUM * * * NOTE 1
S102 1 3'-0" 7'-0" ALUM 1 3/4" N IG-1 5 SF S6 ALUM * * * NOTE 1
S102A 1 3'-0" 7'-0" ALUM 1 3/4" N G-1 5 SF S4 ALUM 3A601
S103 2 6'-0" 7'-0" ALUM 1 3/4" FG G-1 1 SF S1 ALUM 4A601 9A601 SIM
S104 1 3'-0" 7'-0" ALUM 1 3/4" FG G-1 3 SF S1 ALUM 4A601 9A601 SIM
S104A 1 3'-0" 7'-0" WOOD 1 3/4" N 20 MIIN G-2 6 HM-4 HM 8A601 10A601
S105 1 3'-0" 7'-0" WOOD 1 3/4" N 120 MIIN G-3 6 HM-2 HM 2A601
SCALE: 1/4" = 1'-0"
2' 4'0 8'
SCALE: 1 1/2" = 1'-0"
4" 8"0 1'-4"
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
01/18/2024
/1
/2
:4
:1
P M
C
U se rs \k a th ry n fo st e r\ D o cu m e n ts
\1
C ri tz e r, S n o w v ill e S e cu ri ty
V e st ib u le s v k fo st e rW
N
B B
.r v t
A601
D O
O R
A N
D F
IN
IS
H S
C H
E D
U
LE
S
N O
T E
S
A N
D L
E G
E N
D
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
KCF
EFS
EFS
17102
01/18/2024
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
FRAME TYPES
FINISH SCHEDULE
ROOM NO ROOM NAME FLOOR BASE
WALLS CEILING
REMARKSNORTH EAST SOUTH WEST MATERIAL
C101 VESTIBULE VCT RUBBER EXIST EXIST EXIST EXIST EXIST
C102 LOBBY EXIST NONE EXIST EXIST EXIST EXIST ACT-1
C103 NEW OFFICE EXIST RUBBER* PNT PNT PNT PNT EXIST * NOTE 1
C104 NEW RESOURCE OFFICER OFFICE EXIST RUBBER* PNT PNT PNT PNT EXIST * NOTE 1
S101 VESTIBULE VCT RUBBER EXIST EXIST EXIST EXIST EXIST
S102 VESTIBULE VCT RUBBER EXIST EXIST EXIST EXIST EXIST
S103 LOBBY EXIST RUBBER* PNT PNT PNT PNT EXIST * NOTE 1
S104 NEW OFFICE EXIST RUBBER* PNT PNT PNT PNT EXIST * NOTE 1
S105 NEW RESOURCE OFFICER OFFICE EXIST RUBBER* PNT PNT PNT PNT EXIST * NOTE 1
SCALE: 1 1/2" = 1'-0"A602 A601
2 HEAD DETAIL
SCALE: 1 1/2" = 1'-0"A602 A601
1 DETAIL
SCALE: 1 1/2" = 1'-0"A101 A601
3 HEAD DETAIL
SCALE: 1 1/2" = 1'-0"A602 A601
4 HEAD DETAIL
SCALE: 3" = 1'-0"
2" 4"0 8"
SCALE: 1 1/2" = 1'-0"A601
7 HEAD DETAIL
SCALE: 1 1/2" = 1'-0"A602 A601
9 JAMB DETAIL
SCALE: 1 1/2" = 1'-0"A601 A601
8 HEAD DETAIL
SCALE: 1 1/2" = 1'-0"A601 A601
10 JAMB DETAIL
SCALE: 1 1/2" = 1'-0"A602 A601
5 JAMB DETAIL
SCALE: 1 1/2" = 1'-0"A602 A601
6 SILL DETAIL
SCALE: 1 1/2" = 1'-0"A601
11 HEAD DETAIL
SCALE: 1 1/2" = 1'-0"A601
12 JAMB DETAIL
N o
D a te
P u rp o se o f D o cu m e n t
Is
4"
5/ 8"
2"
3/ 8"
2"
8"
2"
0"
IG-1 IG-1 IG-1 IG-1
IG-1 IG-1 IG-1 IG-1
IG-1 IG-1 IG-1 IG-1IG-1 IG-1
2" 2'-6 1/2" 2" 2'-6 1/2" 2" 2'-11" 2" 2'-11" 2"2'-6 1/2" 2" 2'-6 1/2" 2"
17'-2"
2" 9" 2" 6'-0" 2" 9"
2"
8'-2"8'-2"
4"
4"
2"
2"
2"
4"
2"
8"
G-1 G-1
G-1
G-1
G-1
G-1
G-1
A601A602
A601A602
G-1
2"3'-8"2"
4'-0"
2"
0"
2"
4"
2"
0"
0"
G-1
A601A602
OPEN
2"
0"
2"
4"
2"
G-1 G-1 G-1
G-1G-1G-1
G-1
G-1
2'-9 1/8" 2" 2'-8 3/4" 2" 2'-8 3/4" 2" 2'-9" 2"
11'-7 3/4"
0"
0"
6" 2"
A601A602
A601A602
2" 11" 2" 6'-0" 2" 11 1/4"
4 1/2"
2'-1 7/8"
2"
2'-11 1/2"
2"
2'-0" 2"
16'-4"
4"
6"
2"
0"
2"
4"
2"
8"
A602A103
G-1
G-1
G-1 G-1 G-1
G-1 G-1
G-1
G-1
G-1
G-1
G-1
G-1
G-1 G-1
0"
0" 2"
4" 2"
8"
4"
6"
2"
0"
2" 3'-0" 2" 2'-0 1/2" 2" 2'-0 3/4"
4 1/2"
11 3/8" 2" 6'-0" 2" 11" 2"
16'-4"
IG-1
IG-1
IG-1IG-1IG-1IG-1IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1 IG-1 IG-1
3 SIM
A601A101
1'-10" 2" 3'-0" 2" 1'-4"
6'-6"
4"
6"
2"
0"
2"
4"
2"
8"
G-1
G-1
G-1 G-1 G-1
G-1
G-1
G-1
3 SIM
A601A101
A601A101
2" 2'-6 1/2" 2" 2'-6 1/2" 2" 2'-11" 2" 2'-11" 2" 2'-6 1/2" 2" 2'-6 1/2" 2"
17'-2"
4"
1/ 2"
2"
1/ 2"
2"
8"
2"
0"
G-1
G-1
G-1
G-1
G-1
G-1
G-1
G-1
G-1
G-1
G-1
G-1G-1 G-1
NEW THRU-WALL
TRANSACTION DRAWER
RECESSED IN COUNTER
NEW ALUMINUM
STOREFRONT
EXISTING WALL
7/
8"
5/8" GWB
3 5/8" METAL STUD
RUBBER BASE
SOLID SURFACE
COUNTERTOP
0"
EXISTING
MASONRY WALL
NEW THRU-WALL
TRANSACTION DRAWER
EXTENDED POSITION
NEW ALUMINUM
STOREFRONT
7/
8"
PATCH EXISTING
WALL AS NEEDED
A602 A601
BUILT IN TO COUNTERTOP SHURE
SAFE SPT 354 TRANSACTION
DRAWER OR EQUAL
COUNTERTOP
2"
0" 2"
0"
2"
4'-0"
2" 3'-8" 2"
IG-1
A601A602
A601A602
A601A602
G-1 G-1
G-1
G-1
4"
4"
2"
2"
2"
4"
2"
2" 3'-0" 2" 9" 2"
4'-3"
8"
A601A602
GLAZING LEGEND (REFER TO SPECIFICATIONS)
G-2 1/4" FIRE-RESISTANT RATED GLAZING 20 OR 60 MIN RATING WITH BULLET RESISTANT FILM
G-1 1/4" TEMPERED GLASS WITH BULLET RESISTANT FILM
IG-1 1" INSULATED GLAZING WITH BULLET RESISTANT FILM
G-3 1/4" FIRE-RESISTANT RATED GLAZING 120 MIN RATING WITH BULLET RESISTANT FILM
G-4 1/4" TEMPERED GLASS
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
01/18/2024
/1
/2
:4
:1
P M
C
U se rs \k a th ry n fo st e r\ D o cu m e n ts
\1
C ri tz e r, S n o w v ill e S e cu ri ty
V e st ib u le s v k fo st e rW
N
B B
.r v t
A602
S T
O R
E F
R O
N T
E
LE
V A
T
IO
N S
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
KCF
EFS
EFS
17102
01/18/2024
3/8" = 1'-0"
SF C1
3/8" = 1'-0"
SF S2
3/8" = 1'-0"
SF S4
3/8" = 1'-0"
SF S1
3/8" = 1'-0"
SF S5
3/8" = 1'-0"
SF S8
3/8" = 1'-0"
SF S7
SCALE: 3/8" = 1'-0"
6" 1'0 2'
3/8" = 1'-0"
SF C2
SCALE: 3/4" = 1'-0"A103 A602
2 SECTION
SCALE: 3/4" = 1'-0"A601 A602
1 SECTION
SCALE: 3/4" = 1'-0"
8" 1'-4"0 2'-8"
SCALE: 1 1/2" = 1'-0"
4" 8"0 1'-4"
3/8" = 1'-0"
SF C3
3/8" = 1'-0"
SF S3
N o
D a te
P u rp o se o f D o cu m e n t
Is
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:4
:0
P
M C
U se rs
\t a n n e r_ p a sc h a l\
D o cu m e n ts \1
C ri tz e r, S n o w vi ll e
S e cu ri ty V e st ib u le s
E
LE
C tp a sc h a lN
W
K
.r v t
E001
E
LE
C T
R
IC
A L
LE
G
E N
D
G E
N E
R A
L N
O T
E S
A B
B R
E V
IA
T
IO
N
S A
N D
D E
T A
IL
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
TLP
TLP
RMA
17102
01/18/2024
ABBREVIATIONS
GENERAL ELECTRICAL NOTES LEGEND
1. ALL NOTES, SYMBOLS AND ABBREVIATIONS MAY NOT BE APPLICABLE TO THIS PROJECT.
2. COMPLY WITH THE FOLLOWING CODES PERTAINING TO THIS PROJECT:
1. NATIONAL ELECTRIC CODE/ NFPA 70: NEC, 2017
2. VIRGINIA ENERGY CODE: VECC 2018
3. VIRGINIA UNIFORM STATEWIDE BUILDING CODE: VUSBC, 2018
4. ADA STANDARDS FOR ACCESSIBLE DESIGN, ASAD, SEPTEMBER 15, 2010
3. CONTRACTORS SHALL VISIT SITE TO FAMILIARIZE THEMSELVES WITH CONDITIONS TO BE MET IN THE EXECUTION OF THE WORK UNDER
THIS CONTRACT. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR ANY CHANGES THAT MAY BE REQUIRED DUE TO EXISTING SITE
CONDITIONS.
4. PROVIDE INCREASED CONDUCTOR SIZES FOR 120/208 BRANCH CIRCUITS AS FOLLOWS UNO:
CIRCUIT BREAKER 0-100 FT. 100-200 FT. 200-300 FT. OVER 300 FT.
SIZE LENGTH LENGTH LENGTH LENGTH
20 AMP 12 AWG 10 AWG 6 AWG 4 AWG
30 AMP 10 AWG 8 AWG 4 AWG 3 AWG
5. ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FEET SHALL BE PROVIDED WITH A PULLWIRE.
6. DO NOT SHARE NEUTRALS.
7. RECESSED DEVICES MAY BE ADJUSTED TO MATCH MASONRY COURSES IF APPLICABLE. MOUNT ALL BOXES TRUE AND PLUMB. ADJUSTED
MOUNTING HEIGHTS SHALL REMAIN WITHIN ADA REQUIREMENTS.
8. MOUNT RECEPTACLES AT 20" AFF TO TOP, UNLESS OTHERWISE NOTED. ADJUST TO MATCH MASONRY COURSES IF APPLICABLE WITHIN
CODE REQUIREMENTS. MOUNT ALL BOXES TRUE AND PLUMB.
9. RECEPTACLES, SWITCHES, THERMOSTATS, AND OTHER SIMILAR ITEMS SHALL ALIGN VERTICALLY OR HORIZONTALLY WITH EACH OTHER, WITH THE STRUCTURE AND OTHER FEATURES THEREOF WHEN IT APPEARS OBVIOUS AND LOGICAL THAT THEY SHOULD. THE ELECTRICAL
CONTRACTOR SHALL CONSULT WITH THE GENERAL CONSTRUCTION SUPERINTENDENT REGARDING THIS REQUIREMENT AND ALSO FOR
THE LOCATION OF EQUIPMENT, DOOR SWINGS, BLOCK COURSING, ALIGNMENT OF THIS AND OTHER SIMILAR FEATURES BEFORE
ROUGHING-IN FOR THESE COMPONENTS. ADJUSTED MOUNTING HEIGHTS SHALL REMAIN WITHIN ADA REQUIREMENTS.
10. THE MANUFACTURER AND MODEL NUMBER SHOWN ON THE LIGHT FIXTURE SCHEDULE INDICATES THE TYPE, CONSTRUCTION, STYLE, QUALITY AND STANDARD OF PERFORMANCE REQUIRED. OTHER MANUFACTURERS WITH EQUAL PRODUCTS ARE ACCEPTABLE UPON A/E
APPROVAL.
11. COORDINATE LIGHTING LAYOUT WITH ARCHITECTURAL CEILING GRID: THE ELECTRICAL CONTRACTOR SHALL VERIFY THE TYPE OF CEILING
SYSTEM WITH THE GENERAL CONTRACTOR TO INSURE THAT ALL LIGHTING FIXTURES ARE COMPATIBLE WITH THE CEILING SYSTEM BEING
INSTALLED, LIGHTING FIXTURES SHALL NOT BE ORDERED UNTIL THE TYPE OF CEILING HAS BEEN VERIFIED.
12. CONTRACTOR SHALL VERIFY THAT ALL DOOR SWINGS ARE CORRECT BEFORE ROUGHING IN LIGHT SWITCH OUTLETS. LIGHT SWITCHES
SHALL NOT BE LESS THAN 3 NOR MORE THAN 12 INCHES FROM DOOR TRIM.
13. SUSPENDED LIGHTING FIXTURES SHALL NOT BE SUPPORTED FROM MAIN CHANNELS OR TEES OF CEILING SUSPENSION SYSTEM, SUPPORT FIXTURES INDEPENDENTLY OF CEILING MATERIALS BY BUILDING STRUCTURE.
14. LAY-IN FIXTURES SHALL BE INDEPENDENTLY SUPPORTED BY BUILDING STRUCTURE.
15. EXIT SIGNS SHALL NOT BE INSTALLED AS TO BLOCK FIRE ALARM VISUAL DEVICES. MOUNT WALL MOUNTED EXIT SIGNS LOCATED ABOVE
DOORS, 6-INCHES TO THE BOTTOM OF SIGN FROM TOP OF DOOR FRAME.
16. CONNECT FIXTURES INDICATED AS NIGHT LIGHTS ON UN-SWITCHED SIDE OF LIGHTING IN SAME AREA OR CIRCUIT SEPARATELY AS
INDICATED ON PLANS.
17. MOUNT ALL PULL STATIONS 48" AFF TO TOP. MOUNT ALL HORN/STROBES, STROBES AND REMOTE ALARM INDICATORS SUCH THAT THE
ENTIRE LENS IS NOT LESS THAN 80" AFF AND NOT GREATER THAN 96" AFF. COORDINATE LOCATION OF FAN CONTROL RELAY WITH
MECHANICAL CONTRACTOR. PROVIDE DUCT DETECTORS TO MECHANICAL CONTRACTOR FOR MOUNTING. ALL WIRING BY THE ELECTRICAL
CONTRACTOR. MOUNT ALL BOXES TRUE AND PLUMB.
18. MOUNT ALL WALL MOUNTED TELEPHONE/DATA OUTLETS AT 20" AFF TO TOP, UNLESS OTHERWISE NOTED. ADJUST TO MATCH
MASONRY COURSES IF APPLICABLE. FOR WALL MOUNT, PROVIDE A TWO GANG BOX, EXTRA DEEP WITH 2X4 REDUCER PLATE. PROVIDE A
1" CONDUIT AND STUB ABOVE ACCESSIBLE CEILING. TERMINATE CONDUIT ABOVE CEILING WITH INSULATED BUSHING. INSTALL PULL
WIRE. ADJUSTED MOUNTING HEIGHTS SHALL REMAIN WITHIN ADA REQUIREMENTS. ROUGH-IN ONLY SYSTEM, CABLING AND DEVICE BY
OTHERS.
19. ALL CONSTRUCTION DESIGN IS BASED ON EXISTING OWNER PROVIDED DRAWINGS AND FIELD INVESTIGATION. THE CONTRACTOR SHALL
VERIFY ALL ASPECTS IN THE FIELD BEFORE STARTING WORK.
20. LOCATIONS OF LINES AND EQUIPMENT SHALL BE DETERMINED FROM ACTUAL FIELD CONDITIONS. THE OUTLINES OF THE
CONSTRUCTION SHOWN ON THE ELECTRICAL DRAWINGS ARE INTENDED ONLY AS A GUIDE TO INDICATE RELATIVE LOCATIONS OF THE
WORK. REFER TO THE APPLICABLE DRAWINGS OF OTHER TRADES AND THE EQUIPMENT SUPPLIER'S INSTALLATION DRAWINGS FOR EXACT
LOCATIONS AND ARRANGEMENTS.
21. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND PROPER RELATION OF THEIR WORK TO THE
FACILITY STRUCTURES AND TO THE WORK OF OTHER TRADES. NO ADDITIONAL COMPENSATION NOR EXTENSION OF COMPLETION TIME
WILL BE GRANTED FOR EXTRA WORK CAUSED BY THE LACK OF COORDINATION.
22. COORDINATE WITH MECHANICAL ON EXACT LOCATION AND ELECTRICAL CONNECTION REQUIREMENTS FOR HVAC EQUIPMENT
PROVIDED.
23. ELECTRICAL REQUIREMENTS FOR HVAC EQUIPMENT ARE FOR HVAC EQUIPMENT SPECIFIED. IF SUBSTITUTE HVAC EQUIPMENT IS
SUPPLIED, CONTRACTOR IS RESPONSIBLE FOR MODIFICATIONS AND/OR ADDITIONS TO ELECTRICAL REQUIREMENTS OF HVAC EQUIPMENT
SUPPLIED.
24. DUE TO DIFFERENCES IN VARIOUS MANUFACTURER'S EQUIPMENT CONNECTIONS AND MOTOR CURRENTS, THE ELECTRICAL
CONTRACTOR SHALL COORDINATE THEIR INSTALLATION WITH THAT EQUIPMENT ACTUALLY FURNISHED AND SHALL VERIFY THE CORRECT
SIZES AND DETAILS OF INSTALLATION BEFORE ROUGHING IN.
25. THE CORRECT NUMBER OF WIRES MAY NOT BE INDICATED FOR ALL CIRCUITS, ONLY THOSE WHERE CLARIFICATION IS NECESSARY. THE
ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRES NECESSARY FOR THE PROPER FUNCTION OF THE SYSTEM WHETHER INDICATED ON
DRAWINGS OR NOT.
26. ALL CIRCUITS SHALL CONTAIN A PROPERLY SIZED GROUND WIRE. DO NOT USE THE CONDUIT AS THE MEANS OF GROUNDING.
27. EQUIPMENT ENCLOSURE RATINGS: INDOOR NEMA 1 AND OUTDOOR NEMA 3R.
28. HANGERS AND SUPPORTS
A. PRODUCT REQUIREMENTS: FURNISH AND INSTALL APPROVED MATERIALS, SIZES, AND TYPES OF ANCHORS, FASTENERS, AND SUPPORTS
TO CARRY LOADS OF EQUIPMENT AND CONDUIT, INCLUDING WEIGHT OF WIRE IN CONDUIT PLUS 300 POUNDS.
B. MATERIALS AND FINISHES: CORROSION RESISTIVE.
C. ANCHORS AND FASTENERS:
a. CONCRETE SURFACES: SELF-DRILLING ANCHORS AND EXPANSION ANCHORS.
b. HOLLOW MASONRY, PLASTER, AND GYPSUM BOARD PARTITIONS: TOGGLE BOLTS AND HOLLOW WALL FASTENERS.
c. SOLID MASONRY WALLS: EXPANSION ANCHORS.
d. SHEET METAL: SHEET METAL SCREWS.
e. WOOD: WOOD SCREWS.
29. ELECTRICAL IDENTIFICATION
A. PROVIDE PLASTIC NAMEPLATES AT ALL DISCONNECTS. NAMEPLATES SHALL BE THREE-LAYER LAMINATED PLASTIC, WHITE LETTERS
ENGRAVED INTO A BLACK BACKGROUND, WITH 1/4" HIGH LETTERS. FOR DISCONNECTS, IDENTIFY EQUIPMENT SERVED, INCLUDING
VOLTAGE RATINGS. LABEL IN ACCORDANCE WITH NEC ARTICLE 110.22(A) AND 408.4 (B), VUSBC ARTICLE 109.3
B. PROVIDE NEATLY TYPED CIRCUIT BREAKER DIRECTORY IN ALL MODIFIED PANELBOARDS, DIRECTORY SHALL SHOW THE CIRCUIT NUMBER
AND COMPLETE DESCRIPTION OF ALL COMPONENTS ON ALL CIRCUITS, INCLUDING ROOM NUMBERS OR ROOM NAMES WHERE
COMPONENTS ARE LOCATED.
C. PROVIDE WIRE MARKERS ON EACH CONDUCTOR IN PANELBOARDS, PULL BOXES NEW AND EXISTING, OUTLET BOXES, JUNCTION BOXES, AND AT LOAD CONNECTION. IDENTIFY WIRE WITH BRANCH CIRCUIT OR FEEDER NUMBER FOR POWER AND LIGHTING CIRCUITS, AND
WITH CONTROL WIRE NUMBER FOR EQUIPMENT, AS IDENTIFIED ON EQUIPMENT MANUFACTURER'S SHOP DRAWINGS FOR CONTROL
WIRING.
30. PROVIDE CONDUCTORS AS THHN/THWN COPPER. SIZE AS INDICATED.
31. PROVIDE NEW BREAKERS IN EXISTING PANELS MATCHING TYPE AND RATING OF EXISTING PANEL.
32. PROVIDE LABELS FOR BRANCH CIRCUITS WITH EQUIPMENT OR LOADS SERVED, SPACE AND ROOM NUMBERS THAT THE CIRCUIT FEEDS
TO FOR EXISTING AND NEW SWITCHBOARDS, MCC, AND PANEL BOARDS THAT ARE MODIFIED AS A PART OF THIS PROJECT IN
ACCORDANCE WITH NEC 408.4. ALL PANEL SCHEDULES WHERE EQUIPMENT HAS BEEN MODIFIED AS A PART OF THIS PROJECT SHALL BE
UPDATED WITH A TYPED SCHEDULE. PROVIDE ANY ADDITIONAL REVISIONS DURING CONSTRUCTION IN AS-BUILT PLANS.
33. ALL EXTERIOR CONDUIT SHALL BE RGS. INTERIOR DRY LOCATIONS NOT SUBJECT TO PHYSICAL DAMAGE SHALL BE EMT. INTERIOR DRY
LOCATION SUBJECT TO PHYSICAL DAMAGE OR DAMP/WET LOCATIONS SHALL USE RGS.
34. DOOR SECURITY SYSTEM SHALL BE A FULLY OPERATIONAL SYSTEM. CONTRACTOR TO COORDINATE WITH OWNER HARDWARE SUPPLIERS
AND HARDWARE INSTALLERS FOR EQUIPMENT ROUGH-IN AND INSTALLATION DETAILS.
B RECESSED/SURFACE MOUNTED LIGHT FIXTURE, TYPE AS INDICATED. SEE LIGHT FIXTURE
SCHEDULE. NL INDICATES UNSWITCHED NIGHT LIGHT.
B SHADING DENOTES FIXTURE ON EMERGENCY GENERATOR CIRCUIT OR FIXTURE WITH
INTEGRAL EMERGENCY BATTERY FOR EMERGENCY EGRESS LIGHTING. INTEGRAL
BATTERY WHERE USED SHALL BE POWERED AT ALL TIMES. WHERE FIXTURES
INDICATED TO BE SWITCHED, PROVIDE EMERGENCY SHUNT RELAY TO TURN FIXTURE
ON WITH THE LOSS OF POWER REGARDLESS OF SWITCH POSITION. SEE LIGHT FIXTURE
SCHEDULE. NL INDICATES UNSWITCHED NIGHT LIGHT.
WALL MOUNTED EXIT SIGN. SHADING INDICATES FACE AND ARROWS INDICATE
DIRECTIONAL ARROWS WHERE SHOWN. SEE LIGHT FIXTURE SCHEDULE.
EMERGENCY WALL PACK LIGHT. CONNECT AHEAD OF LOCAL SWITCH. SHALL BE
POWERED AT ALL TIMES. SEE LIGHT FIXTURE SCHEDULE. MOUNT AT 8'-0" AFF, UNO.
S LIGHT SWITCH, SINGLE POLE DEVICE, 20 AMP, 120/277 VOLT, FLUSH MOUNT 48" AFF TO TOP OF
BOX. "K" INDICATES KEY OPERATED. "D" INDICATES DIMMER SWITCH. "P" INDICATES PILOT LIGHT.
"M" INDICATED MOTOR RATED SWITCH, NUMBER INDICATES NUMBER OF POLES
S
OS
LIGHT SWITCH, SINGLE POLE DEVICE WITH INTEGRAL OCCUPANCY SENSOR, 20 AMP, 120/277
VOLT, FLUSH MOUNT 48" AFF TO TOP OF BOX. "OS" INDICATES OCCUPANCY SENSOR. "VS"
INDICATES VACANCY SENSOR.
120 V, 20 AMP, DUPLEX CONVENIENCE RECEPTACLE, FLUSH MOUNT 20" AFF TO
TOP OF BOX, NEMA 5-20R.
120 V, 20 AMP, DUPLEX CONVENIENCE RECEPTACLE, FLUSH MOUNT 48" AFF
TO TOP OF BOX, OR 6" ABOVE COUNTERTOP OR BACKSPLASH AS APPLICABLE
TO TOP OF BOX
A-1 A-1 CIRCUIT HOME RUN AND CONNECTION TO DEVICE (PANEL A, CIRCUIT #1), ARROW HEADS
INDICATE NUMBER OF CIRCUITS. PANEL DESIGNATION AS INDICATED. BRANCH CONDUCTORS
ARE #12 AWG COPPER IN 3/4" RACEWAY MINIMUM, UNO. DASHED LINE DENOTES
UNDERGROUND OR UNDER FLOOR CIRCUITS.
JJ JBJ JB JUNCTION BOX / PULL BOX
PANELBOARD
DOOR POSITION SWITCH
DOOR PUSH BOTTON, FLUSH MOUNTED AT 48" TO TOP UNO.
MAGNETIC DOOR HOLDER RELEASE, INTERFACE WITH FIRE ALARM SYSTEM
ES ELECTRIC STRIKE
CARD READER, FLUSH MOUNTED AT 48" TO TOP UNO.CR
FACP FIRE ALARM CONTROL PANEL
FAA FIRE ALARM ANNUNCIATOR PANEL
Z ZAM - ZONE ADDRESSABLE MODULE
F FIRE ALARM MANUAL PULL STATION. FLUSH MOUNT 48" AFF TO TOP OF BOX.
V FIRE ALARM HORN/STROBE LIGHT, MOUNT SUCH THAT ENTIRE LENS IS NOT LESS THAN 80" AFF AND NOT
GREATER THAN 96" AFF.
V FIRE ALARM STROBE LIGHT, MOUNT SUCH THAT ENTIRE LENS IS NOT LESS THAN 80" AFF AND
NOT GREATER THAN 96" AFF.
C DUAL DATA/TELEPHONE OUTLET. MOUNT AT 20" AFF TO TOP, UNO. PROVIDE A TWO GANG BOX, EXTRA
DEEP WITH 2x4 REDUCER PLATE. PROVIDE A 1" CONDUIT TO ABOVE ACCESSIBLE CEILING, TERMINATE
ABOVE CEILING WITH INSULATED BUSHING. "C" INDICATES 48" AFF OR 6" ABOVE COUNTER TO TOP OF
BOX. ROUGH-IN ONLY SYSTEM, CABLING AND DEVICE BY OTHERS.
DASHED INDICATES DEVICE TO BE REMOVED. REMOVE WIRING BACK TO PANEL OR NEAREST
EQUIPMENT REQUIRED TO REMAIN TO SERVE OTHER RETAINED LOADS. ENSURE THAT ALL
DOWNSTREAM LOADS TO REMAIN ARE MAINTAINED. REMOVE ALL BOXES AND CONDUIT EXCLUSIVELY
ASSOCIATED WITH THE DEVICE TO BE REMOVED. IF DEVICE IS IN WALL TO REMAIN, LEAVE BOX AND
CONDUIT AND BLANK OFF WITH NEW COVERPLATE. ABANDON CONDUITS IN SLAB AND SEAL OFF ALL
UNUSED CONDUIT FLUSH WITH SLAB.
(TYPICAL DEVICE
OR FIXTURE)
A, AMP AMPERE
AFF ABOVE FINISHED FLOOR
AWG AMERICAN WIRE GAUGE
C CONDUIT
CB CIRCUIT BREAKER
CU COPPER
DPS DOOR POSITION SWITCH
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
EM EMERGENCY
EX EXISTING TO REMAIN
FA FIRE ALARM
GFI GROUND FAULT INTERRUPTER
GND, G GROUND
HP-1 HEAT PUMP
HP HORSEPOWER
HVAC HEATING, VENTILATION AND AIR CONDITIONING
JB JUNCTION BOX
KVA KILOVOLT AMPERE
KW KILOWATT
MCB MAIN CIRCUIT BREAKER
MLO MAIN LUG ONLY
N NEUTRAL
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL MANUF. ASSOC.
OL OVERLOAD
PB PUSHBUTTON MOMENTARY CONTACT SWITCH
PNL PANEL
REC RECESSED
RGS RIGID GALVANIZED STEEL CONDUIT
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
WP WEATHERPROOF
XFMR TRANSFORMER
CARD READER
STRIKE
RELEASE
CARD READER
Z
NETWORK
CONTINUES
ACCESS CONTROL NETWORK/
MONITORING INTRUSION NETWORK
FIRE ALARM
CONTROL MODULE
NETWORK
CONTINUES
ACCESS CONTROL NETWORK/
MONITORING INTRUSION NETWORK
CR CR
FACP
CEILING
LOCAL CONTROL W/POWER SUPPLY & BATTERY
OR AS GROUPED CONTROL IN TELECOM ROOM,
USE JUNCTION BOX HERE
LOCAL CONTROL W/POWER SUPPLY & BATTERY OR
AS GROUPED CONTROL IN TELECOM ROOM, USE
JUNCTION BOX HERE
CEILING
ELECTRIC
STRIKE
3_
" CONDUIT
3_
" CONDUIT
TYPICAL SINGLE DOOR - DOOR CONTROL/MONITORING TYPICAL DOUBLE DOOR - DOOR CONTROL/MONITORING
NTSNTS
N o
D a te
P u rp o se o f D o cu m e n t
Is s u
CR
V
J
E S
E
SE
S
E S
ES
F
CR
CR
J
J
CR
V
J
E S
E S
F
VESTIBULE
C101
LOBBY
C102
NEW OFFICE
C103
NEW RESOURCE
OFFICER OFFICE
C104
C103A
EXISTING UNLABELED PANEL, SQUARE D
QO LOAD CENTER. LABEL PANEL O FOR
DESIGN PURPOSE
C102 C101
OFFICE OFFICE OFFICE
LOBBY
VESTIBULE
CORRIDOR
CLASSROOM
EXISTING AI PHONE
AND CARD READER
TO REMAIN
DISCONNECT AND
MAINTAIN POWER SUPPLY
FOR DOOR CONTROLS.
RECONNECT IN NEW WORKEXISTING TO
REMAIN
REMOVE 2X4 LIGHT
FIXTURE. MAINTAIN
CIRCUITRY FOR NEW
LIGHTING
REMOVE CAN LIGHT
FIXTURE. MAINTAIN
CIRCUITRY FOR NEW
LIGHTING
REMOVE AND
REPLACE AS SHOWN
IN NEW WORK
EXISTING UNLABELED PANEL, SQUARE D
QO LOAD CENTER. LABEL PANEL O FOR
DESIGN PURPOSE
EXISTING HEATER TO
REMAIN
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:4
:0
P
M C
U se rs
\t a n n e r_ p a sc h a l\
D o cu m e n ts \1
C ri tz e r, S n o w vi ll e
S e cu ri ty V e st ib u le s
E
LE
C tp a sc h a lN
W
K
.r v t
E101
C R
IT
Z
E R
E
LE
M E
N T
A R
Y S
C H
O O
L D
E M
O
LI
T
IO
N
N
E W
W O
R K
P
LA
N S
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
TLP
TLP
RMA
17102
01/18/2024
PLAN NORTH
1/4" = 1'-0"
CRITZER ELEMENTARY NEW WORK FLOOR PLAN
PLAN NORTH
1/4" = 1'-0"
CRITZER ELEMENTARY DEMOLTION FLOOR PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN
SHEET KEYED NOTES:
1. COORDINATE EXACT LOCATIONS OF ALL DEVICES AT RECEPTION COUNTER WITH ARCHITECT AND OWNER PRIOR TO ROUGH-IN.
PROVIDE PUSHBUTTON ROUGH-IN FOR DOOR RELEASE AS FOLLOWS: (1) PUSHBUTTON FOR DOOR C101, (1) PUSHBUTTON FOR
DOOR C102, (1) PUSHBUTTON FOR DOOR C103A. PROVIDE LABEL ON EACH BUTTON FOR DOOR NUMBER CONTROLLED.
2. PROVIDE POWER JUNCTION BOX ABOVE ACCESSIBLE CEILING FOR ACCESS CONTROL. CONNECT TO PANEL O, SPARE 20AMP, 1POLE, 120VOLT BREAKER WITH 2#12 THWN CU, 1#12 THWN CU G, IN 3/4" EMT.
3. PROVIDE RECEPTACLE CIRCUIT TO PANEL O, SPARE 20AMP, 1POLE, 120VOLT BREAKER WITH 2#12 THWN CU, 1#12 THWN CU G, IN
3/4" EMT.
4. RECONNECT EXISTING DOOR POWER TO NEW DOOR CONTROLS.
5. PROVIDE RECEPTACLE CIRCUIT TO PANEL O, SPARE 20AMP, 1POLE, 120VOLT BREAKER WITH 2#12 THWN CU, 1#12 THWN CU G, IN
3/4" EMT.
GENERAL SHEET NOTES:
1. EXISTING FIRE ALARM CONTROL PANEL IS SIMPLEX. LOCATED IN MAIN OFFICE 101.
2. EXISTING DOOR ACCESS SYSTEM IS HONEYWELL SYSTEM. NEW DEVICES AND CONTROLS SHALL BE COMPATIBLE AND INTERFACE
WITH EXISTING SYSTEM. SEE KEYPLAN FOR APPROXIMATE LOCATION.
3. IF THERE ARE NO SPARE BREAKERS IN EXISTING PANELS, PROVIDE NEW 20AMP, 1POLE BREAKER, MATCHING EXISTING
MANUFACTURER AND RATINGS.
4. COORDINATE DEVICE MOUNTING WITH CASEWORK DETAILS ON ARCHITECTURE SHEETS.
APPROXIMATE
LOCATION OF EXISTING
DOOR ACCESS
CONTROL PANELS IN
STORAGE RM 301
DEMOLITION FLOOR PLAN LINE LEGEND
DEMOLITION
EXISTING TO REMAIN
NEW WORK LINE LEGEND
NEW CONSTRUCTION
EXISTING TO REMAIN
NTS
APPROXIMATE
LOCATION OF EXISTING
FACP IN MAIN OFFICE
N o
D a te
P u rp o se o f D o cu m e n t
Is
C102
C103
C104 RELOCATE EXISTING FIXTURES AS NECESSARY TO
AVOID NEW WORK WALLS.
NEW FLAT LED PANEL 2X4 FIXTURE. CONNECT TO
EXISTING LIGHTING CIRCUITRY AND CONTROL.
EXTEND CIRCUITRY AS REQUIRED, MATCH
EXISTING TYPE AND SIZE
EXISTING HEATER TO
REMAIN
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:4
:0
P
M C
U se rs
\t a n n e r_ p a sc h a l\
D o cu m e n ts \1
C ri tz e r, S n o w vi ll e
S e cu ri ty V e st ib u le s
E
LE
C tp a sc h a lN
W
K
.r v t
E102
C R
IT
Z
E R
E
LE
M E
N T
R Y
S C
H O
O L
LI
G
H T
IN
G
P
LA
N
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
TLP
TLP
RMA
17102
01/18/2024
PLAN NORTH
1/4" = 1'-0"
CRITZER ELEMENTARY LIGHTING PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN
GENERAL SHEET NOTES:
1. NEW LED FLAT PANEL FIXTURE SHALL BE, OR BE SIMILAR TO LITHONIA - CPX 2X4 AL08 80CRI SWW7 SWL MVOLT. SET LUMEN
4000LM AND COLOR TEMPERATURE TO MATCH EXISTING HALLWAY COLOR TEMPERATURE.
2. PROVIDE EMERGENCY BATTERY OPTION 'E10WLCP' WHERE INIDCATED WITH HATCHING.
3. NEW LED 6" DOWNLIGHT FIXTURE SHALL BE, OR BE SIMILAR TO LITHONIA - LDN6 ALO4 SWW1 LO6 AR LSS MVOLT. SET LUMEN
4000LM AND COLOR TEMPERATURE TO MATCH EXISTING HALLWAY COLOR TEMPERATURE.
NTS
NEW WORK LINE LEGEND
NEW CONSTRUCTION
EXISTING TO REMAIN
N o
D a te
P u rp o se o f D o cu m e n t
Is
F A C P
F A A
V
F
J
J
J
J
C R
C R
J
ESES
ES ES
E S
ES
FF
F A C P
F A A
V
F
CR
VESTIBULE
S102
LOBBY
S103
CORRIDOR
AI PHONE
NEW RESOURCE
OFFICER OFFICE
S105
NEW OFFICE
S104
Z
S104A
EXISTING PANEL LC, SIEMENS TYPE S1
EXISTING DOOR ACCESS CONTROLS
RELOCATED AI PHONE,
EXTEND ASSOCIATED
CIRCUITRY AS NECESSARY,
MATCH TYPE AND SIZE
RELOCATED CARD READER.
CONNECT TO NEW DOOR
CONTROLS. EXTEND ASSOCIATED
CIRCUITRY AS NECESSARY, MATCH
TYPE AND SIZE
RELOCATED FIRE ALARM
PULL STATION, EXTEND
ASSOCIATED CIRCUITRY AS
NECESSARY, MATCH TYPE
AND SIZE
EXISTING PORTION OF
PLUGMOLD TO REMAIN.
RE-ROUTE POWER AS
NECESSARY TO MAINTAIN
EXISTING PORTION OF
PLUGMOLD TO REMAIN.
RE-ROUTE POWER AS
NECESSARY TO MAINTAIN
S103
S101A
S101
S102A
S102
DISCONNECT AND REMOVE CARD
READER. MAINTAIN FOR RELOCATION
IN NEW WORK.
DISCONNECT AND REMOVE AI PHONE.
MAINTAIN FOR RELOCATION IN NEW
WORK.
DISCONNECT AND REMOVE PORTION
OF PLUGMOLD THAT INTERFERES WITH
NEW WORK
MAINTAIN EXISTING RECEPTACLE, RE-
ROUTE POWER AS NECESSARY TO
MAINTAIN
DISCONNECT AND REMOVE PORTION
OF PLUGMOLD THAT INTERFERES WITH
NEW WORK
EXISTING PANEL LC
EXISTING DOOR ACCESS CONTROLS
DISCONNECT AND REMOVE FIRE ALARM
PULL STATION. MAINTAIN FOR
RELOCATION IN NEW WORK.
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:4
:0
P
M C
U se rs
\t a n n e r_ p a sc h a l\
D o cu m e n ts \1
C ri tz e r, S n o w vi ll e
S e cu ri ty V e st ib u le s
E
LE
C tp a sc h a lN
W
K
.r v t
E103
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O L
D E
M O
LI
T
IO
N
N
E W
W O
R K
P
LA
N S
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
TLP
TLP
RMA
17102
01/18/2024
PLAN NORTH
1/4" = 1'-0"
SNOWVILLE ELEMENTARY NEW WORK FLOOR PLAN
PLAN NORTH
1/4" = 1'-0"
SNOWVILLE ELEMENTARY DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN
SHEET KEYED NOTES:
1. COORDINATE EXACT LOCATIONS OF ALL DEVICES AT RECEPTION COUNTER WITH ARCHITECT AND OWNER PRIOR TO ROUGH-IN.
PROVIDE PUSHBUTTON ROUGH-IN FOR DOOR RELEASE AS FOLLOWS: (1) PUSHBUTTON FOR DOOR S102, (1) PUSHBUTTON FOR DOOR
102A, (1) PUSHBUTTON FOR DOOR 103. PROVIDE LABEL ON EACH BUTTON FOR DOOR NUMBER CONTROLLED.
2. PROVIDE POWER JUNCTION BOX ABOVE ACCESSIBLE CEILING FOR ACCESS CONTROL. CONNECT TO PANEL LC, SPARE 20AMP, 1POLE, 120VOLT BREAKER WITH 2#12 THWN CU, 1#12 THWN CU G, IN 3/4" EMT.
3. PROVIDE RECEPTACLE CIRCUIT TO PANEL LC, SPARE 20AMP, 1POLE, 120VOLT BREAKER WITH 2#12 THWN CU, 1#12 THWN CU G, IN
3/4" EMT.
4. PROVIDE POWER JUNCTION BOX ABOVE ACCESSIBLE CEILING FOR DOOR MAG HOLD OPEN. CONNECT TO PANEL LC, SPARE 20AMP, 1POLE, 120VOLT BREAKER WITH 2#12 THWN CU, 1#12 THWN CU G, IN 3/4" EMT. PROVIDE ZAM AND CONNECTION TO FIRE ALARM
SYSTEM SO THAT DOOR IS RELEASED UPON FIRE ALARM ACTIVATION.
5. PROVIDE RECEPTACLE CIRCUIT TO PANEL LC, SPARE 20AMP, 1POLE, 120VOLT BREAKER WITH 2#12 THWN CU, 1#12 THWN CU G, IN
3/4" EMT.
GENERAL SHEET NOTES:
1. EXISTING FIRE ALARM CONTROL PANEL IS SIMPLEX.
2. EXISTING DOOR ACCESS SYSTEM IS HONEYWELL SYSTEM. NEW DEVICES AND CONTROLS SHALL BE COMPATIBLE AND INTERFACE
WITH EXISTING SYSTEM.
3. IF THERE ARE NO SPARE BREAKERS IN EXISTING PANELS, PROVIDE NEW 20AMP, 1POLE BREAKER, MATCHING EXISTING
MANUFACTURER AND RATINGS.
4. COORDINATE DEVICE MOUNTING WITH CASEWORK DETAILS ON ARCHITECTURE SHEETS.
DEMOLITION FLOOR PLAN LINE LEGEND
DEMOLITION
EXISTING TO REMAIN
NEW WORK LINE LEGEND
NEW CONSTRUCTION
EXISTING TO REMAIN
CLASSROOMCORRIDOR
MAIN OFFICE
MAIN LOBBY
MAIN OFFICE
NTS
N o
D a te
P u rp o se o f D o cu m e n t
Is
S102
S104 S103
S105
Sheet No.
Seal
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
/1
/2
:4
:0
P
M C
U se rs
\t a n n e r_ p a sc h a l\
D o cu m e n ts \1
C ri tz e r, S n o w vi ll e
S e cu ri ty V e st ib u le s
E
LE
C tp a sc h a lN
W
K
.r v t
E104
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O L
LI
G
H T
IN
G
P
LA
N
S E
C U
R
IT
Y V
E S
T
IB
U
LE
S F
O R
C R
IT
Z
E R
S N
O W
V
IL
LE
E
LE
M
E N
T A
R Y
S C
H O
O
LS
TLP
TLP
RMA
17102
01/18/2024
PLAN NORTH
1/4" = 1'-0"
SNOWVILLE ELEMENTARY LIGHTING PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN
MAINTAIN EXISTING FIXTURES, RELOCATE LIGHT
FIXTURES AS NECESSARY TO AVOID NEW
CONSTRUCTION WALLS, TYP. COORDINATE WITH
EXISTING DEVICES AND MECHANICAL DIFFUSERS
MAINTAIN EXISTING FIXTURES, RELOCATE
LIGHT FIXTURES AS NECESSARY TO AVOID
NEW CONSTRUCTION WALLS, TYP.
COORDINATE WITH EXISTING DEVICES AND
MECHANICAL DIFFUSERS
RELOCATE EXISTING LOCAL
SPEAKER OUTSIDE OF OFFICE TO
APPROXIMATE LOCATION SHOWN
NTS
N o
D a te
P u rp o se o f D o cu m e n t
Is
| Sheets |
| G001 - TITLE SHEET |
| G002 - PROJECT INFORMATION AND DATA |
| A101 - CRITZER ELEMENTARY SCHOOL DEMOLITION & NEW WORK PLANS |
| A102 - CRITZER ELEMENTRY SCHOOL REFLECTED CEILING PLAN & INTERIOR ELEVATIONS |
| A103 - SNOWVILLE ELEMENTARY SCHOOL DEMOLITION & NEW WORK PLANS |
| A104 - SNOWVILLE ELEMENTARY REFLECTED CEILING PLAN & INTERIOR ELEVATIONS |
| A601 - DOOR AND FINISH SCHEDULES, NOTES, AND LEGEND |
| A602 - STOREFRONT ELEVATIONS |