This is an Addendum No. 1 issued August 15, 2025, by the Michigan Department of Technology, Management & Budget (DTMB) and Michigan Department of Corrections (MDOC) for the Escanaba State Office Building Rooftop Unit Replacement project (DTMB File No. 171/24438.JBB). The project involves replacement of rooftop mechanical units at the state office building located at 305 Ludington Street in Escanaba, Michigan. The bid date remains Wednesday, August 27, 2025, with no changes to the original bidding schedule. The contract duration has been extended to 240 calendar days. All bidders must provide proof of State Project Registration from the Department of Labor and Economic Opportunity. The contractor must provide three weeks' advance notification for any electrical or HVAC system shutdowns, and the awarded contractor must have electrical utility representation at the pre-construction meeting. A mandatory pre-bid meeting was held, with an attendance sign-in sheet attached to the addendum.
A limited asbestos and lead survey was conducted on May 21, 2025, by TriMedia Environmental & Engineering Services, Inc., with results included in the addendum. The survey analyzed 24 samples (32 sample layers) from suspect asbestos-containing materials and lead-based paint in areas scheduled for renovation. Laboratory analysis by EMSL Analytical, Inc. using EPA Method 600/R-93/116 and polarized light microscopy determined that asbestos was not detected at regulated levels in any sampled materials and no suspect lead-based paint was identified in areas to be disturbed. The addendum clarifies that air balance testing does not need to be completed within seven days as previously listed, and requires that all new and existing roof piping be painted safety yellow in accordance with exterior painting specifications.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM NO. 1
DATE: August 15, 2025
PROJECT: Escanaba State Office Building Rooftop Unit Replacement
DTMB File No.: 171/24438.JBB
OWNER: MI DTMB/MDOC
BID DATE: Wednesday, August 27, 2025 ** THIS ADDENDUM DOES NOT CHANGE THE BID
DATE**
The following shall be incorporated into the Contract Documents dated 2025 AUG 01.
GENERAL
The sign-in sheet for the Mandatory pre-bid meeting is attached.
All bid responses require proof of State Project Registration from the Department of Labor and Economic Opportunity.
For scheduling purposes of the State building the contractor must provide a 3 week notification of shutdown of the electrical or HVAC system.
The awarded contractor shall have representation from the electrical utility at the pre-construction meeting.
PROJECT MANUAL
APPENDIX III- SPECIAL PROJECT PROCEURES
Added TRIMEDIA – SUMMARY REPORT – LIMITED ASBESTOS AND LEAD SURVEY
00100 – INSTRUCTIONS TO BIDDERS
Revision – Contract time shall be lengthened to 240 calendar days.
00800 – SUPPLEMENTARY WORKING CONDITIONS
Clarification – It shall be noted that the air balance does not need to be completed within the 7 days listed within this section.
230593 – FACILITY NATURAL GAS PIPING
Clarification – The project will require new and existing piping on the roof to be painted safety yellow in accordance with section 099113 EXTERIOR PAINTING.
DRAWINGS
End of Addendum No. 1
830 W. Washington Street Marquette, MI 49855
906.228.5125
906.228.5126 Fax
www.trimediaee.com
Sent Via Electronic Mail June 6, 2025 Mr. Louis Meyette, PE, Senior Project Manager OHM Advisors 424 Hancock Street Hancock, Michigan 49930
Re: Summary Report – Limited Asbestos and Lead Survey at the State Office Building in Escanaba, Michigan TriMedia Project Number 2025-1810
Dear Mr. Meyette:
TriMedia Environmental & Engineering Services, Inc. (TriMedia) has prepared this correspondence to summarize the results of the limited hazardous materials sampling at the Escanaba State Office Building located at 305 Ludington Street Escanaba, Michigan. The intent of this information and data is to assist OHM Advisors in identifying hazardous materials related to proposed renovation activities at the site, with scope limited to the renovation areas. This correspondence also includes a summary of analytical laboratory results.
TriMedia was on-site on May 21, 2025 to conduct sampling to identify the presence of asbestos-containing materials (ACM) and lead-containing paint within the areas of the identified building where renovations will occur as provided in the drawings dated April 30th, 2025. Renovations are planned to occur to the mechanical system on the roof of the building which is powered by the electrical system in the first-floor mechanical room. The assessment is intended to identify building contaminants that, if mismanaged during renovation activities, could pose an environmental or health and safety concern.
ASBESTOS SURVEY
TriMedia collected a total of 24 samples (consisting of 32 sample layers) of suspect asbestos-containing materials to be submitted for laboratory analysis. Each suspect asbestos-containing material sampled was containerized in a laboratory-supplied sealable bag; labeled with a material description, sample location, and a unique sample number; and, shipped under chain of custody to EMSL Analytical, Inc., (EMSL) in Indianapolis, Indiana for analysis under EPA Method 600/R-93/116 utilizing polarized light microscopy techniques.
ASBESTOS RESULTS
Asbestos was not detected at regulated levels in the materials sampled.
Complete analytical laboratory results have been enclosed for your records. Sampled materials, locations, and analytical results have been summarized in Table 1: Materials Sampled and Found to Not Contain Asbestos.
Mr. Louis Meyette, PE, Senior Project Manager
LEAD CONTAINING PAINT SURVEY
No suspect lead-based paint was identified by TriMedia that will be disturbed as outlined in the renovation plans.
SUMMARY OF FINDINGS AND RECOMMENDATIONS
Asbestos or lead based paint was not found in the materials sampled that will be disturbed as part of planned roof top mechanical system upgrades.
TriMedia made every reasonable attempt to access all areas of the planned renovations. However, as with all inspections, there exists the potential for discovering additional suspect materials not addressed by this report during renovation/demolition activities. In the event suspect materials are identified during on-site activities, they must be sampled before being disturbed.
It is hoped this Summary Report meets your needs and expectations. Should you have any questions regarding this correspondence, or the project in general, please do not hesitate to contact the undersigned at (906) 228-5125 or via email at tsorensen@trimediaee.com. On behalf of the professional staff at TriMedia, thank you for the opportunity to be of service to OHM Advisors.
Sincerely, TriMedia Environmental & Engineering Services, LLC
Kelly Levely, ASP Tim Sorensen, ASP Project Scientist Senior Industrial Hygienist Asbestos Inspector A43125 Asbestos Inspector A43037
TRS/jet
Enclosures: Table 1: Materials Sampled and Found to Not Contain Asbestos Photo Log EMSL Analytical Report – Asbestos cc: TriMedia Project File 2025-1810
Limitations: Information presented in this Summary Report was prepared for OHM Advisors and its authorized parties only.
Any use a third party makes of this report, or any reliance on or decisions to be made based upon, are the responsibility of such third party.
mailto:tsorensen@trimediaee.com
Table 1 Materials Sampled and Found to Not Contain Asbestos
OHM
State Office Building
Escanaba, MI TriMedia 2025-1810
Sample Date: May 21, 2025
Sample #
(Layers) Material/Description
001 A&B Roof Curb Patch Seal
002 A&B Roof Side pan Rubber Roofing
003 A&B Roof Curb Insulation / Felt
004 A&B Roof Curb Caulk / Rubber Roof
005 A&B Roof Side Pan Rubber Roof
006 A&B Roof Curb Rubber Roofing
007 A&B Roof Heating Unit Base Corner Silicon
008 A&B Roof Top of Curb Under Heating Unit Caulk
009 A&B Roof Heating Unit Penetration Caulk
010 A&B Roof Heating Unit Penetration Caulk
011 A&B Roof Heating Unit Penetration Caulk
012 A&B Roof Thread Seal Thread Seal
Location Details
PHOTO LOG
OHM – ASBESTOS SAMPLING
ESCANABA STATE BUILDING
TriMedia Project # 2025-1810
Description: State Building
Date: 05/21/2025 Taken By: KDL
Description: Electric Panel Mechanical East Wall
Description: 001 A&B Roof Curb Patch Seal
Description: 001 A&B Roof Curb Patch Seal
Description: 002 A&B Roof Side Pan Rubber Roofing
Description: 007 A&B Roof Heating Unit Base Corner Silicon
Description: 008 A&B Roof Top of Curb Under Heating Unit Caulk
Description: 008 A&B Roof Top of Curb Under Heating Unit Caulk
Description: 009 A&B Roof Heating Unit Penetration Caulk
Description: 009 A&B Roof Heating Unit
Description: 010 A&B Roof Heating Unit
Description: 010 A&B Roof Heating Unit
Description: 011 A&B Roof Heating Unit
Description: 011 A&B Roof Heating Unit
Description: 012 A&B Roof Thread Seal Thread Seal
Description: 012 A&B Roof Thread Seal Thread Seal
EMSL Analytical, Inc.
6340 CastlePlace Dr. Indianapolis, IN 46250
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162506703EMSL Order:
Customer ID: TRIC50
Customer PO:
Project ID:
Attention: Phone:Kelly Levely (906) 228-5125
Fax:TriMedia Environmental & Engineering Svs (906) 228-5126
Received Date:830 W. Washington St 05/23/2025 9:55 AM
Analysis Date:Marquette, MI 49855 06/02/2025
Collected Date:
Project: 2025-18180 OHM ESKY
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
001A
162506703-0001
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
PATCH SEAL
001B
162506703-0002
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
PATCH SEAL
002A-Rubber
Membrane
162506703-0003
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
RUBBER ROOF
002A-Mastic
162506703-0003A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
RUBBER ROOF
002B-Rubber
Membrane
162506703-0004
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
RUBBER ROOF
002B-Mastic
162506703-0004A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
RUBBER ROOF
003A-Insulation
162506703-0005
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
INSULATION / FELT
003A-Felt
162506703-0005A
None DetectedNon-fibrous (Other)20%Synthetic80%Gray/Black
Fibrous
Homogeneous
INSULATION / FELT
003B-Insulation
162506703-0006
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
INSULATION / FELT
003B-Felt
162506703-0006A
None DetectedNon-fibrous (Other)30%Synthetic70%Gray/Black
Fibrous
Homogeneous
INSULATION / FELT
004A-Caulk
162506703-0007
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
CAULK / RUBBER
ROOF
004A-Rubber
Membrane
162506703-0007A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
CAULK / RUBBER
ROOF
004B-Caulk
162506703-0008
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
CAULK / RUBBER
ROOF
004B-Rubber
Membrane
162506703-0008A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
CAULK / RUBBER
ROOF
005A
162506703-0009
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
RUBBER ROOF
Initial report from: 06/02/2025 12:42:36
Page 1 of 3ASB_PLM_0008_0002 - 2.31 Printed: 6/2/2025 12:42 PM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162506703EMSL Order:
Customer ID: TRIC50
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
005B
162506703-0010
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
RUBBER ROOF
006A
162506703-0011
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
RUBBER ROOF
006B
162506703-0012
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
RUBBER ROOF
007A
162506703-0013
None DetectedNon-fibrous (Other)100%Gray/Clear
Non-Fibrous
Homogeneous
SILICON
007B
162506703-0014
None DetectedNon-fibrous (Other)100%Gray/Clear
Non-Fibrous
Homogeneous
SILICON
008A
162506703-0015
None DetectedNon-fibrous (Other)100%Gray/Black
Non-Fibrous
Homogeneous
CAULK
008B
162506703-0016
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
CAULK
009A
162506703-0017
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
CAULK
009B
162506703-0018
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
CAULK
010A
162506703-0019
None DetectedNon-fibrous (Other)98%Cellulose2%Gray
Non-Fibrous
Homogeneous
CAULK
010B
162506703-0020
None DetectedNon-fibrous (Other)95%Cellulose5%Gray
Non-Fibrous
Homogeneous
CAULK
011A
162506703-0021
None DetectedNon-fibrous (Other)100%White/Black
Non-Fibrous
Homogeneous
CAULK
011B
162506703-0022
None DetectedNon-fibrous (Other)100%White/Black
Non-Fibrous
Homogeneous
CAULK
012A-Thread Seal
162506703-0023
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
THREAD SEAL
012A-Tape
162506703-0023A
None DetectedNon-fibrous (Other)100%Blue
Non-Fibrous
Homogeneous
THREAD SEAL
012B-Thread Seal
162506703-0024
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
THREAD SEAL
012B-Tape
162506703-0024A
None DetectedNon-fibrous (Other)100%Blue
Non-Fibrous
Homogeneous
THREAD SEAL
Page 2 of 3ASB_PLM_0008_0002 - 2.31 Printed: 6/2/2025 12:42 PM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162506703EMSL Order:
Customer ID: TRIC50
Customer PO:
Project ID:
Analyst(s)
Hilary Jarvis (16)
Ross Matlock (16)
Asbestos Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Indianapolis, IN NVLAP Lab Code 200188-0, AZ0939, CA 2575, CO AL-15132, TX 300262, A2LA Accredited - Certificate #2845.25
Page 3 of 3ASB_PLM_0008_0002 - 2.31 Printed: 6/2/2025 12:42 PM
OrderID: 162506703
OrderID: 162506703
| ADDENDUM NO. 1 |
| GENERAL |
| The sign-in sheet for the Mandatory pre-bid meeting is attached. |
| All bid responses require proof of State Project Registration from the Department of Labor and Economic Opportunity. |
| PROJECT MANUAL |
| DRAWINGS |
File details come from the government source that posted it. Updated .