17-Attachment 13 Asset Detail Machine Shed 2020.pdf
PDF 296 KB Posted
- Attached to
- Trimborn Farm Use & Development
- Solicitation number
- RFP-ED2501
- Issued by
- Milwaukee County, Green Bay City, Wisconsin
About this file
The document is an Asset Detail Report from VFA for a Wooden Building (Machine Shed) located at Trimborn Farm in Greendale, Wisconsin, owned by Milwaukee County. The asset is a one-story, 720 square foot structure built in the 1850s, currently used as a Museum & Art Center for guided educational tours. The building is classified as an Assembly Occupancy with an IBC Type V-B, Unprotected Wood Frame construction. The asset has a poor condition rating as of June 9, 2020, with a current replacement value of $87,534 and total requirements cost of $40,857.
The report outlines several renewal requirements with estimated costs, including branch wiring and device renewal ($2,079), exterior door renewal ($12,612), fire extinguisher replacement ($113), and roofing renewal ($15,158). Many of these requirements are categorized as "Beyond Useful Life" with priorities ranging from 1-Currently Critical to 4-Future Planning. The action dates for these renewals span from June 9, 2021 to June 9, 2040. The building lacks HVAC, plumbing, and has minimal electrical systems, with potential hazardous materials presumed present due to its 1850s construction date. The report also notes the building does not have accessible entry thresholds and requires various maintenance and compliance upgrades.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asset Detail Report By Asset Name
Department/Division: Museum & Art CentersAsset: Wooden Building (Machine Shed) Site: Trimborn Farm Asset Number: 3157
Assets are ordered by Asset Name Currency: USD
Statistics
FCI Cost: 25,002 FCI: 0.29 RI Cost: 40,857 RI: 0.47 Total Requirements Cost: 40,857 Asset Condition Rating: Poor
Current Replacement Value: 87,534 Date of most Recent Assessment:
Jun 9, 2020
Type Building Area 720 SF Use Museum / Art Center Construction Type IBC - Type V B Floors 1 Historical Category On Register
Address 1 8801 W Grange Ave City Greendale Address 2 - State/Province/Region UNITED STATES OF AMERICA Year Constructed 1850 Zip/Postal Code 53129 Year Renovated - Architect - Ownership MILW County - Owned Commission Date -
Decommission Date -
Inventory: No Occupancy Classification: A-3 Assembly
Insurable Value of Building: 0 Insurable Value of Contents: 0
Mission Category: Category 3
Photo
Wooden Building (Machine Shed)
Asset Description
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:47:29 PM Page 1 of 4
Building General Description:
The Wooden Building (Machine Shed), Asset #3156, is located at Trimborn Farm at W.
Grange Ave., Greendale, WI
53219.
building is a one (1) story, square foot structure built in the 1850’s.
Building interior is used to provide guided educational tours of a historic machine shed.
Per the IBC Chapter 3 and the Wisconsin Administrative Code, SPS 354, the building is classified primarily as Assembly Occupancy. According to the IBC Chapter 6 and the Wisconsin Administrative Code, SPS 351.02, the facility is primarily construction
TYPE
V-B, Unprotected Wood Frame, as determined from field observations and as-built drawings.
building has the following general systems:
ARCHITECTURAL/STRUCTURAL
SYSTEMS
Foundation Walls and Footings Concrete- Ft
Building Structure Wood Framed
Veneer Siding
Windows Wood Single Glazing
Exterior Doors Barn -12 x7
Roofing
Shingles
Slab on Grade Concrete
5"
HANDICAPPED
ACCESSIBILITY
Building 3156's compliance with handicapped accessibility was evaluated utilizing International Building Code - ICC/ANSI A117.1, and
ADAAG.
This building is not exempt per the Codes.
The building does not have accessible entry thresholds
HAZARDOUS
MATERIALS
An asbestos report was not provided for this building, however, based on the 1850’s date of construction asbestos and lead containing materials are presumed to be present in the building.
MECHANICAL
HVAC
[none]
PLUMBING:
[none]
FIRE
PROTECTION:
Fire Extinguisher Dry Chem
ELECTRICAL
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:47:29 PM Page 2 of 4
(1) Distribution Panel
PB-006
Branch Wiring, Equipment and Devices
Lighting Interior Fixtures
DISCLAIMER
This report reflects equipment or system deficiencies, and construction cost estimates to correct those deficiencies. The construction cost estimates may not reflect the actual total project costs. The construction cost estimates do not include costs for project management, owner services, planning and design, plan review fees, construction management, construction general conditions, overhead and profit, testing services and design and construction contingencies. All projects need to be submitted to the AE & ES section of DAS-FM to verify actual cost estimates for any Capital Improvement Project (CIP) budget requests.
Requirements
Requirement Name Renewal Prime System Category Priority Action Date Estimated
Cost
Branch Wiring, Equipment & Devices Renewal
Yes D5021 - Branch Wiring Devices
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 2,079
Building Structure - Wood Framed Renewal
Yes B1020 - Roof Construction
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 1,166
Exterior Doors - Barn - 12 x 7 Wood Renewal
Yes B2030 - Exterior Doors
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 12,612
Fire Extinguisher - Dry Chem Renewal
Yes D4031 - Fire Extinguishers
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 113
Lighting - Interior Fixtures Renewal Yes D5022 - Lighting Equipment
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 1,222
Panel PB-006 - 30A 120/240V 1PH 2C MLO Renewal
Yes D5012 - Low Tension Service and Dist.
Beyond Useful Life
1 - Currently Critical
Jun 9, 2021 1,677
Repair Wood Siding & Refinish No B2010 - Exterior Walls
Integrity 3 - Necessary Not Yet Critical
Jun 9, 2025 3,411
Replace Broken LB Cover No D5021 - Branch Wiring Devices
Code Compliance
1 - Currently Critical
Jun 9, 2021 59
Replace Duplex Receptacle with GFCI Device
No D5021 - Branch Wiring Devices
Code Compliance
5 - Does Not Meet
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:47:29 PM Page 3 of 4
Requirement Name Renewal Prime System Category Priority Action Date Estimated
Cost
Current Codes or Standards
Replace Missing Door Hardware No B2030 - Exterior Doors
Security 1 - Currently Critical
Jun 9, 2021 231
Roofing - Wood Shingles Renewal Yes B3010 - Roof Coverings
Beyond Useful Life
1 - Currently Critical
Jun 9, 2020 15,158
Slab on Grade - Concrete 5" Renewal
Yes A1030 - Slab on Grade
Beyond Useful Life
4 - Future Planning
Jun 9, 2040 371
Veneered Walls - Wood Siding Renewal
Yes B2010 - Exterior Walls
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 1,242
Windows - Wood - Single Glazing Renewal
Yes B2020 - Exterior Windows
Beyond Useful Life
1 - Currently Critical
Jun 9, 2020 1,396
Total 40,857
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:47:29 PM Page 4 of 4
File details come from the government source that posted it. Updated .