14-Attachment 14 Asset Detail Milk House 2020.pdf

PDF 307 KB Posted

Attached to
Trimborn Farm Use & Development
Solicitation number
RFP-ED2501
Issued by
Milwaukee County, Green Bay City, Wisconsin

About this file

This is a VFA Asset Detail Report for the Milk House (Pump House), Asset #3152, located at Trimborn Farm in Greendale, Wisconsin. The one-story, 297-square-foot building was constructed in the 1850s and is currently used as a Museum & Art Center. The asset is owned by Milwaukee County and is classified as an A-3 Assembly occupancy under IBC Type III-B construction. The building contains display artifacts from the Trimborn Farm historical site and covers an abandoned water well.

The asset detail report outlines various renewal requirements with estimated costs totaling $38,137. Key renewal needs include branch wiring equipment and devices ($1,141), exterior doors replacement ($4,946), roofing wood shingles renewal ($9,684), and windows wood single glazing renewal ($3,927). The building's condition is rated as "Poor" as of June 9, 2020, and potential hazardous materials like asbestos and lead are presumed present due to its 1850s construction. Most renewal actions are categorized as "Beyond Useful Life" with priorities ranging from 3-Necessary Not Yet Critical to 4-Future Planning, with action dates spanning from June 2022 to June 2030.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asset Detail Report By Asset Name

Department/Division: Museum & Art CentersAsset: Milk House (Pump House) Site: Trimborn Farm Asset Number: 3152

Assets are ordered by Asset Name Currency: USD

Statistics

FCI Cost: 35,607 FCI: 0.56 RI Cost: 38,137 RI: 0.60 Total Requirements Cost: 38,137 Asset Condition Rating: Poor

Current Replacement Value: 63,615 Date of most Recent Assessment:

Jun 9, 2020

Type Building Area 297 SF Use Museum / Art Center Construction Type IBC - Type III B Floors 1 Historical Category On Register

Address 1 8801 W Grange Ave City Greendale Address 2 - State/Province/Region UNITED STATES OF AMERICA Year Constructed 1850 Zip/Postal Code 53129 Year Renovated - Architect - Ownership MILW County - Owned Commission Date -

Decommission Date -

Inventory: No Occupancy Classification: A-3 Assembly

Insurable Value of Building: 0 Insurable Value of Contents: 0

Mission Category: Category 3

Photo

Milk House (Pump House)

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 1 of 5

Milk House (Pump House)

Asset Description

Building General Description:

The Milk House (Pump House), Asset #3152, is located within Trimborn Farm, at W Grange Ave, Greendale, WI

53129.

building is a one (1) story, square foot structure built in the 1850’s.

The building interior includes: Display artifacts from the Trimborn Farm historical site. The building covers the abandoned Trimborn Farm water well.

Per the IBC Chapter 3 and the Wisconsin Administrative Code, SPS 354, the building is classified primarily as Assembly Occupancy, A-3. According to the IBC Chapter 6 and the Wisconsin Administrative Code, SPS 351.02, the facility is primarily construction

TYPE

III-B,

Joisted Masonry Unprotected, as determined from field observations and as-built drawings.

building has the following general systems:

ARCHITECTURAL/STRUCTURAL

SYSTEMS

Foundation Walls and Footings Concrete Block

4Ft.

Building Structure Wood Framed

Veneer Siding

Exterior Walls Concrete Block

Windows Wood Single Glazing

Exterior Doors X

Roofing

Shingles

Fascia

Board

Slab on Grade Concrete 5"

HANDICAPPED

ACCESSIBILITY

Building 3152's compliance with handicapped accessibility was evaluated utilizing International Building Code - ICC/ANSI

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 2 of 5

A117.1, and

ADAAG.

This building is not exempt per the Codes.

The building does not have an accessible entry threshold.

HAZARDOUS

MATERIALS

An asbestos report was not provided for this building, however, based on the 1850’s date of construction asbestos and lead containing materials are presumed to be present in the building.

MECHANICAL

HVAC

(none)

PLUMBING

(none)

FIRE

PROTECTION

Fire Extinguisher Dry Chem

ELECTRICAL

(1) Distribution Panel

PB-005

Branch Wiring, Equipment and Devices

Lighting Interior Fixtures

DISCLAIMER

This report reflects equipment or system deficiencies, and construction cost estimates to correct those deficiencies. The construction cost estimates may not reflect the actual total project costs. The construction cost estimates do not include costs for project management, owner services, planning and design, plan review fees, construction management, construction general conditions, overhead and profit, testing services and design and construction contingencies. All projects need to be submitted to the AE & ES section of DAS-FM to verify actual cost estimates for any Capital Improvement Project (CIP) budget requests.

Requirements

Requirement Name Renewal Prime System Category Priority Action Date Estimated

Cost

Branch Wiring, Equipment & Devices Renewal

Yes D5021 - Branch Wiring Devices

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 1,141

Building Structure - Wood Framed Renewal

Yes B1020 - Roof Construction

Beyond Useful Life

4 - Future Planning

Jun 9, 2030 261

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 3 of 5

Requirement Name Renewal Prime System Category Priority Action Date Estimated

Cost

Exterior Doors - 3 x 7 Wood Renewal

Yes B2030 - Exterior Doors

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 4,946

Exterior Walls - Concrete Block Renewal

Yes B2010 - Exterior Walls

Beyond Useful Life

4 - Future Planning

Jun 9, 2030 1,129

Fascia - Wood Board Renewal Yes B3015 - Roof Eaves and Soffits

Beyond Useful Life

2 - Potentially Critical

Jun 9, 2022 6,831

Fire Extinguisher - Dry Chem Renewal

Yes D4031 - Fire Extinguishers

Beyond Useful Life

4 - Future Planning

Jun 9, 2030 113

Foundation Walls and Footings - Concrete Block - 4 Ft. Renewal

Yes A1010 - Standard Foundations

Beyond Useful Life

4 - Future Planning

Jun 9, 2030 722

Lighting - Interior Fixtures Renewal

Yes D5022 - Lighting Equipment

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 2,010

Panel PB-005 - 40A 120/240V 1PH 2C MLO Renewal

Yes D5012 - Low Tension Service and Dist.

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 3,781

Repair Damaged Siding No B2010 - Exterior Walls

Integrity 1 - Currently Critical

Jun 9, 2021 459

Repair or Replace Deteriorated Windows

No B2020 - Exterior Windows

Functionality 1 - Currently Critical

Jun 9, 2021 838

Replace Chimney Cap No B3010 - Roof Coverings

Functionality 3 - Necessary Not Yet Critical

Jun 9, 2025 1,514

Roofing - Wood Shingles Renewal Yes B3010 - Roof Coverings

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 9,684

Slab on Grade - Concrete 5" Renewal

Yes A1030 - Slab on Grade

Beyond Useful Life

4 - Future Planning

Jun 9, 2030 306

Trim Plants & Vines No B2010 - Exterior Walls

Integrity 2 - Potentially Critical

Jun 9, 2023 69

Veneered Walls - Wood Siding Yes B2010 - Beyond Useful 3 - Jun 9, 2025 406

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 4 of 5

Requirement Name Renewal Prime System Category Priority Action Date Estimated

Cost

Renewal Exterior Walls Life Necessary Not Yet Critical

Windows - Wood - Single Glazing Renewal

Yes B2020 - Exterior Windows

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 3,927

Total 38,137

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 5 of 5