This is a VFA Asset Detail Report for the Milk House (Pump House), Asset #3152, located at Trimborn Farm in Greendale, Wisconsin. The one-story, 297-square-foot building was constructed in the 1850s and is currently used as a Museum & Art Center. The asset is owned by Milwaukee County and is classified as an A-3 Assembly occupancy under IBC Type III-B construction. The building contains display artifacts from the Trimborn Farm historical site and covers an abandoned water well.
The asset detail report outlines various renewal requirements with estimated costs totaling $38,137. Key renewal needs include branch wiring equipment and devices ($1,141), exterior doors replacement ($4,946), roofing wood shingles renewal ($9,684), and windows wood single glazing renewal ($3,927). The building's condition is rated as "Poor" as of June 9, 2020, and potential hazardous materials like asbestos and lead are presumed present due to its 1850s construction. Most renewal actions are categorized as "Beyond Useful Life" with priorities ranging from 3-Necessary Not Yet Critical to 4-Future Planning, with action dates spanning from June 2022 to June 2030.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asset Detail Report By Asset Name
Department/Division: Museum & Art CentersAsset: Milk House (Pump House) Site: Trimborn Farm Asset Number: 3152
Assets are ordered by Asset Name Currency: USD
Statistics
FCI Cost: 35,607 FCI: 0.56 RI Cost: 38,137 RI: 0.60 Total Requirements Cost: 38,137 Asset Condition Rating: Poor
Current Replacement Value: 63,615 Date of most Recent Assessment:
Jun 9, 2020
Type Building Area 297 SF Use Museum / Art Center Construction Type IBC - Type III B Floors 1 Historical Category On Register
Address 1 8801 W Grange Ave City Greendale Address 2 - State/Province/Region UNITED STATES OF AMERICA Year Constructed 1850 Zip/Postal Code 53129 Year Renovated - Architect - Ownership MILW County - Owned Commission Date -
Decommission Date -
Inventory: No Occupancy Classification: A-3 Assembly
Insurable Value of Building: 0 Insurable Value of Contents: 0
Mission Category: Category 3
Photo
Milk House (Pump House)
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 1 of 5
Milk House (Pump House)
Asset Description
Building General Description:
The Milk House (Pump House), Asset #3152, is located within Trimborn Farm, at W Grange Ave, Greendale, WI
53129.
building is a one (1) story, square foot structure built in the 1850’s.
The building interior includes: Display artifacts from the Trimborn Farm historical site. The building covers the abandoned Trimborn Farm water well.
Per the IBC Chapter 3 and the Wisconsin Administrative Code, SPS 354, the building is classified primarily as Assembly Occupancy, A-3. According to the IBC Chapter 6 and the Wisconsin Administrative Code, SPS 351.02, the facility is primarily construction
TYPE
III-B,
Joisted Masonry Unprotected, as determined from field observations and as-built drawings.
building has the following general systems:
ARCHITECTURAL/STRUCTURAL
SYSTEMS
Foundation Walls and Footings Concrete Block
4Ft.
Building Structure Wood Framed
Veneer Siding
Exterior Walls Concrete Block
Windows Wood Single Glazing
Exterior Doors X
Roofing
Shingles
Fascia
Board
Slab on Grade Concrete 5"
HANDICAPPED
ACCESSIBILITY
Building 3152's compliance with handicapped accessibility was evaluated utilizing International Building Code - ICC/ANSI
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 2 of 5
A117.1, and
ADAAG.
This building is not exempt per the Codes.
The building does not have an accessible entry threshold.
HAZARDOUS
MATERIALS
An asbestos report was not provided for this building, however, based on the 1850’s date of construction asbestos and lead containing materials are presumed to be present in the building.
MECHANICAL
HVAC
(none)
PLUMBING
(none)
FIRE
PROTECTION
Fire Extinguisher Dry Chem
ELECTRICAL
(1) Distribution Panel
PB-005
Branch Wiring, Equipment and Devices
Lighting Interior Fixtures
DISCLAIMER
This report reflects equipment or system deficiencies, and construction cost estimates to correct those deficiencies. The construction cost estimates may not reflect the actual total project costs. The construction cost estimates do not include costs for project management, owner services, planning and design, plan review fees, construction management, construction general conditions, overhead and profit, testing services and design and construction contingencies. All projects need to be submitted to the AE & ES section of DAS-FM to verify actual cost estimates for any Capital Improvement Project (CIP) budget requests.
Requirements
Requirement Name Renewal Prime System Category Priority Action Date Estimated
Cost
Branch Wiring, Equipment & Devices Renewal
Yes D5021 - Branch Wiring Devices
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 1,141
Building Structure - Wood Framed Renewal
Yes B1020 - Roof Construction
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 261
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 3 of 5
Requirement Name Renewal Prime System Category Priority Action Date Estimated
Cost
Exterior Doors - 3 x 7 Wood Renewal
Yes B2030 - Exterior Doors
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 4,946
Exterior Walls - Concrete Block Renewal
Yes B2010 - Exterior Walls
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 1,129
Fascia - Wood Board Renewal Yes B3015 - Roof Eaves and Soffits
Beyond Useful Life
2 - Potentially Critical
Jun 9, 2022 6,831
Fire Extinguisher - Dry Chem Renewal
Yes D4031 - Fire Extinguishers
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 113
Foundation Walls and Footings - Concrete Block - 4 Ft. Renewal
Yes A1010 - Standard Foundations
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 722
Lighting - Interior Fixtures Renewal
Yes D5022 - Lighting Equipment
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 2,010
Panel PB-005 - 40A 120/240V 1PH 2C MLO Renewal
Yes D5012 - Low Tension Service and Dist.
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 3,781
Repair Damaged Siding No B2010 - Exterior Walls
Integrity 1 - Currently Critical
Jun 9, 2021 459
Repair or Replace Deteriorated Windows
No B2020 - Exterior Windows
Functionality 1 - Currently Critical
Jun 9, 2021 838
Replace Chimney Cap No B3010 - Roof Coverings
Functionality 3 - Necessary Not Yet Critical
Jun 9, 2025 1,514
Roofing - Wood Shingles Renewal Yes B3010 - Roof Coverings
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 9,684
Slab on Grade - Concrete 5" Renewal
Yes A1030 - Slab on Grade
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 306
Trim Plants & Vines No B2010 - Exterior Walls
Integrity 2 - Potentially Critical
Jun 9, 2023 69
Veneered Walls - Wood Siding Yes B2010 - Beyond Useful 3 - Jun 9, 2025 406
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:39:07 PM Page 4 of 5
Requirement Name Renewal Prime System Category Priority Action Date Estimated
Cost
Renewal Exterior Walls Life Necessary Not Yet Critical
Windows - Wood - Single Glazing Renewal
Yes B2020 - Exterior Windows
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 3,927
Total 38,137