12-Attachment 10 Asset Detail Granary Barn 2020.pdf

PDF 319 KB Posted

Attached to
Trimborn Farm Use & Development
Solicitation number
RFP-ED2501
Issued by
Milwaukee County, Green Bay City, Wisconsin

About this file

This is an Asset Detail Report by VFA for a Granary Barn located at Trimborn Farm in Greendale, Wisconsin, managed by the Museum & Art Centers department. The two-story, 1,444 square foot structure was built in the 1850s and is owned by Milwaukee County. The building is classified as an Assembly Occupancy with an Unprotected Wood Frame construction type, currently used for historical museum storage. The asset is rated in "Poor" condition with a current replacement value of $193,732.

The report details numerous maintenance and renewal requirements totaling $92,335, with priority levels ranging from "Currently Critical" to "Future Planning". Key renewal needs include exterior walls, wood siding, roofing, windows, lighting, electrical systems, and fire protection equipment. Most renewal actions are scheduled between 2021-2025, with estimated costs ranging from $113 to $15,743 per item. The document notes potential hazardous materials like asbestos and lead due to the building's 1850s construction, and highlights that the building lacks accessible entry thresholds and does not have HVAC or plumbing systems.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asset Detail Report By Asset Name

Department/Division: Museum & Art CentersAsset: Granary Barn Site: Trimborn Farm Asset Number: 3151

Assets are ordered by Asset Name Currency: USD

Statistics

FCI Cost: 90,697 FCI: 0.47 RI Cost: 92,333 RI: 0.48 Total Requirements Cost: 92,335 Asset Condition Rating: Poor

Current Replacement Value: 193,732 Date of most Recent Assessment:

Jun 9, 2020

Type Building Area 1,444 SF Use Museum / Art Center Construction Type IBC - Type V B Floors 2 Historical Category On Register

Address 1 8801 W Grange Ave City Greendale Address 2 - State/Province/Region UNITED STATES OF AMERICA Year Constructed 1850 Zip/Postal Code 53129 Year Renovated - Architect - Ownership MILW County - Owned Commission Date -

Decommission Date -

Inventory: No Occupancy Classification: A-3 Assembly

Insurable Value of Building: 0 Insurable Value of Contents: 0

Mission Category: Category 3

Photo

Granary Barn

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 1 of 5

Granary Barn

Asset Description

Building General Description:

The Bunkhouse/Granary Barn,, Asset #3151, is located within Trimborn Farm, at W Grange Ave, Greendale, WI

53129.

building is a two (2) story, 1,444 square foot structure built in 1850’s.

Building interior includes:

Historical Museum storage.

Per the IBC Chapter 3 and the Wisconsin Administrative Code, SPS 354, the building is classified primarily as Assembly Occupancy. According to the IBC Chapter 6 and the Wisconsin Administrative Code, SPS 351.02, the facility is primarily construction

TYPE

V-B, Unprotected Wood Frame, as determined from field observations and as-built drawings.

building has the following general systems:

ARCHITECTURAL/STRUCTURAL

SYSTEMS

Foundation Walls and Footings Concrete Ft

Floor Structure Wood Loft

Building Structure Wood Framed

Exterior Walls Brick Infill

Veneered Walls Wood Siding

Windows Wood Single Glazing

Exterior Doors x Wood

Roofing Wood Shingle

Fascia Wood Board

Slab on Grade Concrete 5"

Stair Wood

Interior

HANDICAPPED

ACCESSIBILITY

Building 3151's compliance with handicapped accessibility was evaluated utilizing International Building Code - ICC/ANSI

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 2 of 5

A117.1, and ADAAG. This building is not exempt per the Codes. The building does not have accessible entry thresholds or access to the second floor storage area.

HAZARDOUS

MATERIALS

An asbestos report was not provided for this building, however, based on the 1850’s date of construction asbestos and lead containing materials are presumed to be present in the building.

MECHANICAL

HVAC

(none)

PLUMBING

(none)

FIRE

PROTECTION

There is a hand held

ABC

fire extinguisher located in the building.

ELECTRICAL

SYSTEMS

Distribution Panel

PB-004

120/240V 100A

1PH

Branch Wiring, Equipment and Devices

Lighting Interior Fixtures

DISCLAIMER

This report reflects equipment or system deficiencies, and construction cost estimates to correct those deficiencies. The construction cost estimates may not reflect the actual total project costs. The construction cost estimates do not include costs for project management, owner services, planning and design, plan review fees, construction management, construction general conditions, overhead and profit, testing services and design and construction contingencies. All projects need to be submitted to the AE & ES section of DAS-FM to verify actual cost estimates for any Capital Improvement Project (CIP) budget requests.

Requirements

Requirement Name Renewal Prime System Category Priority Action Date Estimated

Cost

Branch Wiring, Equipment & Devices Renewal

Yes D5021 - Branch Wiring Devices

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 4,170

Exterior Doors - 3 x 7 Wood Yes B2030 - Beyond Useful 2 - Jun 9, 2023 4,946

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 3 of 5

Requirement Name Renewal Prime System Category Priority Action Date Estimated

Cost

Renewal Exterior Doors Life Potentially Critical

Exterior Walls - Brick Infill Renewal Yes B2010 - Exterior Walls

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 3,522

Fascia - Wood Board Renewal Yes B3015 - Roof Eaves and Soffits

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 15,743

Fire Extinguisher - Dry Chem Renewal

Yes D40 - Fire Protection

Beyond Useful Life

4 - Future Planning

Jun 9, 2030 113

Floor Structure - Wood - Loft Renewal

Yes B1010 - Floor Construction

Beyond Useful Life

4 - Future Planning

Jun 9, 2040 1,523

Lighting - Interior Fixtures Renewal

Yes D5022 - Lighting Equipment

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 7,350

Panel PB-004 - 100A 120/240V 1PH C MLO Renewal

Yes D5012 - Low Tension Service and Dist.

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 3,781

Refinish Exterior Wood Doors No B2030 - Exterior Doors

Maintenance 1 - Currently Critical

Jun 9, 2021 612

Repair Brick Alignment No B2010 - Exterior Walls

Integrity 2 - Potentially Critical

Jun 9, 2023 2,846

Repair Concrete Slab Crack No A1030 - Slab on Grade

Integrity 1 - Currently Critical

Jun 9, 2021 1,812

Repair Foundation Wall Spalls No A1010 - Standard Foundations

Integrity 2 - Potentially Critical

Jun 9, 2023 1,223

Roofing - Wood Shingles Renewal Yes B3010 - Roof Coverings

Beyond Useful Life

2 - Potentially Critical

Jun 9, 2022 15,158

Stair - Wood - Interior Renewal Yes C2010 - Stair Construction

Beyond Useful Life

3 - Necessary Not Yet Critical

Jun 9, 2025 848

Update Window Finish No B2020 - Exterior

Integrity 1 - Currently Critical

Jun 9, 2021 6,360

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 4 of 5

Requirement Name Renewal Prime System Category Priority Action Date Estimated

Cost

Windows

Veneered Walls - Wood Siding Renewal

Yes B2010 - Exterior Walls

Beyond Useful Life

1 - Currently Critical

Oct 9, 2020 15,695

Windows - Wood - Single Glazing Renewal

Yes B2020 - Exterior Windows

Beyond Useful Life

2 - Potentially Critical

Jun 9, 2023 6,633

Total 92,335

Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 5 of 5