About this file
This is an Asset Detail Report by VFA for a Granary Barn located at Trimborn Farm in Greendale, Wisconsin, managed by the Museum & Art Centers department. The two-story, 1,444 square foot structure was built in the 1850s and is owned by Milwaukee County. The building is classified as an Assembly Occupancy with an Unprotected Wood Frame construction type, currently used for historical museum storage. The asset is rated in "Poor" condition with a current replacement value of $193,732.
The report details numerous maintenance and renewal requirements totaling $92,335, with priority levels ranging from "Currently Critical" to "Future Planning". Key renewal needs include exterior walls, wood siding, roofing, windows, lighting, electrical systems, and fire protection equipment. Most renewal actions are scheduled between 2021-2025, with estimated costs ranging from $113 to $15,743 per item. The document notes potential hazardous materials like asbestos and lead due to the building's 1850s construction, and highlights that the building lacks accessible entry thresholds and does not have HVAC or plumbing systems.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asset Detail Report By Asset Name
Department/Division: Museum & Art CentersAsset: Granary Barn Site: Trimborn Farm Asset Number: 3151
Assets are ordered by Asset Name Currency: USD
Statistics
FCI Cost: 90,697 FCI: 0.47 RI Cost: 92,333 RI: 0.48 Total Requirements Cost: 92,335 Asset Condition Rating: Poor
Current Replacement Value: 193,732 Date of most Recent Assessment:
Jun 9, 2020
Type Building Area 1,444 SF Use Museum / Art Center Construction Type IBC - Type V B Floors 2 Historical Category On Register
Address 1 8801 W Grange Ave City Greendale Address 2 - State/Province/Region UNITED STATES OF AMERICA Year Constructed 1850 Zip/Postal Code 53129 Year Renovated - Architect - Ownership MILW County - Owned Commission Date -
Decommission Date -
Inventory: No Occupancy Classification: A-3 Assembly
Insurable Value of Building: 0 Insurable Value of Contents: 0
Mission Category: Category 3
Photo
Granary Barn
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 1 of 5
Granary Barn
Asset Description
Building General Description:
The Bunkhouse/Granary Barn,, Asset #3151, is located within Trimborn Farm, at W Grange Ave, Greendale, WI
53129.
building is a two (2) story, 1,444 square foot structure built in 1850’s.
Building interior includes:
Historical Museum storage.
Per the IBC Chapter 3 and the Wisconsin Administrative Code, SPS 354, the building is classified primarily as Assembly Occupancy. According to the IBC Chapter 6 and the Wisconsin Administrative Code, SPS 351.02, the facility is primarily construction
TYPE
V-B, Unprotected Wood Frame, as determined from field observations and as-built drawings.
building has the following general systems:
ARCHITECTURAL/STRUCTURAL
SYSTEMS
Foundation Walls and Footings Concrete Ft
Floor Structure Wood Loft
Building Structure Wood Framed
Exterior Walls Brick Infill
Veneered Walls Wood Siding
Windows Wood Single Glazing
Exterior Doors x Wood
Roofing Wood Shingle
Fascia Wood Board
Slab on Grade Concrete 5"
Stair Wood
Interior
HANDICAPPED
ACCESSIBILITY
Building 3151's compliance with handicapped accessibility was evaluated utilizing International Building Code - ICC/ANSI
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 2 of 5
A117.1, and ADAAG. This building is not exempt per the Codes. The building does not have accessible entry thresholds or access to the second floor storage area.
HAZARDOUS
MATERIALS
An asbestos report was not provided for this building, however, based on the 1850’s date of construction asbestos and lead containing materials are presumed to be present in the building.
MECHANICAL
HVAC
(none)
PLUMBING
(none)
FIRE
PROTECTION
There is a hand held
ABC
fire extinguisher located in the building.
ELECTRICAL
SYSTEMS
Distribution Panel
PB-004
120/240V 100A
1PH
Branch Wiring, Equipment and Devices
Lighting Interior Fixtures
DISCLAIMER
This report reflects equipment or system deficiencies, and construction cost estimates to correct those deficiencies. The construction cost estimates may not reflect the actual total project costs. The construction cost estimates do not include costs for project management, owner services, planning and design, plan review fees, construction management, construction general conditions, overhead and profit, testing services and design and construction contingencies. All projects need to be submitted to the AE & ES section of DAS-FM to verify actual cost estimates for any Capital Improvement Project (CIP) budget requests.
Requirements
Requirement Name Renewal Prime System Category Priority Action Date Estimated
Cost
Branch Wiring, Equipment & Devices Renewal
Yes D5021 - Branch Wiring Devices
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 4,170
Exterior Doors - 3 x 7 Wood Yes B2030 - Beyond Useful 2 - Jun 9, 2023 4,946
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 3 of 5
Requirement Name Renewal Prime System Category Priority Action Date Estimated
Cost
Renewal Exterior Doors Life Potentially Critical
Exterior Walls - Brick Infill Renewal Yes B2010 - Exterior Walls
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 3,522
Fascia - Wood Board Renewal Yes B3015 - Roof Eaves and Soffits
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 15,743
Fire Extinguisher - Dry Chem Renewal
Yes D40 - Fire Protection
Beyond Useful Life
4 - Future Planning
Jun 9, 2030 113
Floor Structure - Wood - Loft Renewal
Yes B1010 - Floor Construction
Beyond Useful Life
4 - Future Planning
Jun 9, 2040 1,523
Lighting - Interior Fixtures Renewal
Yes D5022 - Lighting Equipment
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 7,350
Panel PB-004 - 100A 120/240V 1PH C MLO Renewal
Yes D5012 - Low Tension Service and Dist.
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 3,781
Refinish Exterior Wood Doors No B2030 - Exterior Doors
Maintenance 1 - Currently Critical
Jun 9, 2021 612
Repair Brick Alignment No B2010 - Exterior Walls
Integrity 2 - Potentially Critical
Jun 9, 2023 2,846
Repair Concrete Slab Crack No A1030 - Slab on Grade
Integrity 1 - Currently Critical
Jun 9, 2021 1,812
Repair Foundation Wall Spalls No A1010 - Standard Foundations
Integrity 2 - Potentially Critical
Jun 9, 2023 1,223
Roofing - Wood Shingles Renewal Yes B3010 - Roof Coverings
Beyond Useful Life
2 - Potentially Critical
Jun 9, 2022 15,158
Stair - Wood - Interior Renewal Yes C2010 - Stair Construction
Beyond Useful Life
3 - Necessary Not Yet Critical
Jun 9, 2025 848
Update Window Finish No B2020 - Exterior
Integrity 1 - Currently Critical
Jun 9, 2021 6,360
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 4 of 5
Requirement Name Renewal Prime System Category Priority Action Date Estimated
Cost
Windows
Veneered Walls - Wood Siding Renewal
Yes B2010 - Exterior Walls
Beyond Useful Life
1 - Currently Critical
Oct 9, 2020 15,695
Windows - Wood - Single Glazing Renewal
Yes B2020 - Exterior Windows
Beyond Useful Life
2 - Potentially Critical
Jun 9, 2023 6,633
Total 92,335
Copyright 2025 VFA, Inc. All rights reserved. Aug 25, 2025 2:36:51 PM Page 5 of 5