This document is a request for proposal for the operation of the Grafton Job Corps Center, a five year contract opportunity with a two-year base period and three one-year option periods. The Department of Labor Office of the Assistant Secretary for Administration and Management is seeking proposals to operate the residential facility, which provides career technical training and academic programs to help young people ages 16-24 earn a high school diploma or industry-recognized certification. Proposals are due by February 15, 2023 and the contract is expected to be awarded by May 15, 2023. The incumbent contractor is not specified. The attached RFP and paperclipped attachments provide full details on the required services, facility operations, educational programs, and pricing terms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 002-1605JE-23-R-00004 Grafton.pdf | ||
| Grafton 1605JE-23-R-00004 Amd 0001.pdf | ||
| Grafton JCC - 1605JE-23-R-00004.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GRAFTON
Job Corps Center North Grafton, MA
Facility Planning Report Supporting Data
Volume II
Final May 2022
GRAFTON JOB CORPS CENTER
PY 2021 FACILITY SURVEY REPORT
VOLUME II – TABLE OF CONTENTS
1.0 EXECUTIVE SUMMARY
2.0 SITE LAYOUT AND PLANS
Location Map
Existing Site Plan
3.0 DESCRIPTIONS
Buildings and Structures
Space Utilization by function
NSF by Building
Environmental Management Report
Radon Report
Site Description
Building Descriptions and Structures, Floor Plans
4.0 DEFICIENCIES
APPENDICES – CORRESPONDENCE AND REPORTS
APPENDIX A
Survey Brief ............................................................................................................................... A-2
APPENDIX B
Life Safety Deficiencies and List ................................................................................................ B-1
APPENDIX C
O&M Deficiencies List ............................................................................................................... C-1 i
Asbestos Report
Center Review Meeting Minutes................................................................................................ A-1
Page Intentionally Left Blank ii
1.0 EXECUTIVE SUMMARY
1.0 EXECUTIVE
SUMMARY
EXECUTIVE SUMMARY
The Program Year 2021 facility survey for Grafton Job Corps Center was completed the week of November 08, 2021. The information presented in Volume II, Supporting Data, represents the current status of the campus.
The information includes the following:
• Existing site layout
• Overall status of existing building and structures
• Space utilization by building and function compared to recommended standards
• Status of environmental elements of the Center’s operations
• Details on the site and buildings and structures based on architectural, electrical, and mechanical survey and supporting documentation
• Presentation of the status of historical deficiencies and compilation of deficiencies documented through this survey
• Supporting documentation, as presented in the appendices of the center review meeting; survey brief and student questionnaire; life safety IA/IIA transmittal; and active warranties
Section 1.0 of this volume addresses site layout and plans while Section 2.0 presents details on the buildings and structures. Section 3.0 presents deficiencies and their status as well as new ones identified in this survey. The appendices provide additional information as noted below:
• Appendix A. Survey Brief Questionnaire
• Appendix B. Life Safety Deficiencies and List
• Appendix C. O&M Deficiencies List
2.0 SITE LAYOUT AND PLANS
2.0 SITE LAYOUT
AND PLANS
Page Intentionally Left Blank
3.0 DESCRIPTIONS
3.0 DESCRIPTIONS
BUILDINGS AND STRUCTURES
00104 GRAFTON 04/06/2022
1Page: of Date:
0001 - PINES A HEALTH & BUSINESS
CLERICAL
0002 - PINES B RECREATION
0006 - FORMER CULINARY ARTS
(VACANT)
0007 -
VOCATIONS/LOGISTICS/WAREHOUSE/M
AINT
0008 - CONSTRUCTION TRADES
0009 - BASIC EDUCATION
0010 - FORMER EDUCATION (VACANT)
0013 - FORMER OFFICE SPACE
(VACANT)
0014 - GATE HOUSE/SECURITY
0015 - STORAGE
0016 - STORAGE
0017 - DORM/ADMIN/MED/DENT
0018 - GYMNASIUM
0025 - CAFETERIA
0026 - CULINARY ARTS/CPP
0001A - MAINTENANCE STORAGE (18 ft 8 in x 20 ft) 0002A - INFORMATION SIGN (4Ft x 4Ft)
0007A - FLAMMABLE STORAGE SHED (10
ft x 10 ft) 0007B - SAND STORAGE SHED (20 ft x 26 ft) 0008B - CONSTRUCT TR STRG SHED (6 ft 8 in x 12 ft) 0008D - STORAGE SHED (8Ft x 8Ft) 0008E - STORAGE TRAILER (8Ft x 16Ft)
0008F - EMERGENCY GENERATOR
COVER (12Ft x 16Ft) 0008G - MOCK-UP STRUCTURE (12 ft x 8 ft) 0009A - CHILLER (10Ft x 8Ft) 0018A - GYM STORAGE SHED (9 ft x 12 ft) 0019 - SEWER BUILDING (14 ft 8 in x 14 ft 8 in) 0024 - EMERGENCY GENERATOR (10 ft x 12 ft) 0028 - BUS STOP (4 ft x 12 ft) 00T1 - BUILDING 25 TRANSFORMER (4Ft x 4Ft) 00T2 - BUILDING 26 TRANSFORMER (4Ft x 4Ft) 00T3 - BUILDING 17 TRANSFORMER (4Ft x 4Ft) 00T4 - BUILDING 1 TRANSFORMER (4Ft x 4Ft)
BB-1 - BASEBALL FIELD
Name GSF
14,475
21,750 24,850
22,613
12,180 11,500 6,550
11,545
2,800 1,700
57,100 9,520
13,000 10,180
Active
Active Active
Active
Active Active Active Active
Active Active Active Active Active Active Active Active
Active Active
Active
Active
Active Active Active
Active
Active Active Active
Active
Active Active
Active
Active
Active
Active
StatusType
Building
Building Building
Building
Building Building Building Building
Building Building Building Building Building Building Building Structure
Structure Structure
Structure
Structure
Structure Structure Structure
Structure
Structure Structure Structure
Structure
Structure Structure
Structure
Structure
Structure
Structure
Use Group Built Flrs Const
B
A-3 B
B,S-2
B,F-1 B B Business
B S-2 S-2 R-2,B A-3 A-2 Business S-2
Utility/Misc.
H
S-2
S-2
Storage Storage Utility/Misc.
Utility/Misc.
Utility/Misc.
S-2 Utility/Misc.
U
Utility/Misc.
Utility/Misc.
Utility/Misc.
Utility/Misc.
Utility/Misc.
Utility/Misc.
Fair
Fair Poor
Fair
Fair Fair Poor Poor
Good Fair Fair Fair
Good Good Good Fair
Good Good
Fair
Good
Good Good Good
Good
Good Good Fair
Good
Good Good
Good
Good
Good
Good
ConditionAsset Number
0010400002
0010400003 0010400006
0010400007
0010400008 0010400009 0010400010 0010400013
0010400014 0010400016 0010400017 0010400018 0010400021 0010408132 0010408146 0010400019
0010408153 0010408142
0010408143
0010408141
0010408151 0010408152 0010408156
0010408158
0010408147 0010408140 0010408128
0010408136
0010408144 0010408148
0010408149
0010408150
0010408154
0010408157
BUILDINGS AND STRUCTURES
00104 GRAFTON 04/06/2022
2Page: of Date:
15 220,363
19 2,336
34 222,699
Buildings
Structures
Total
GSF
GSF
GSF
Summary
04/06/2022
Space Utilization By Function 00104 Grafton Page: 1 of Date:
HOUSING
EDUCATION
FOOD SERVICE
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
Resident Men Resident Women Total Residents
Residents 206 Non Residents 31
237Total Students
(206)
(237)
(237)
DIFFERENCE
22,248
18,010
4,266
36,140
38,868
9,405
Lounge Other Shower/Toilet Sleeping excl. SPD( rooms; 0 beds) Storage
Academic (237) Non-Academic
4 -- ACT (Off-Ctr) 30 -- Carpentry + 30 -- Culinary Arts + 48 -- Electrical + 30 -- Health Occupations + 10 -- Manufacturing Technology + 30 -- Medical Assistant 24 -- Plumbing + 30 -- Security Services
Vocational Theory (172)
Dining (2 Servings) Food Preparation Food Storage
7,120 2,550 3,680
19,600 3,190
4,245 11,303
4,000 5,000 4,895 2,810
2,595 2,530
5,365 3,035 1,005
2,060 1,648 2,472
14,832 1,236
2,370 2,370
2,250 1,800 2,400 1,200
1,200 1,050
1,720
1,896 1,422
5,060
1,208 4,768 1,954
1,875 8,933
1,750 3,200 2,495 1,610
1,695 1,330
-340
-940
3,469 1,613
Vocations
13,892
20,858
5,139
04/06/2022
Space Utilization By Function 00104 Grafton Page: 2 of Date:
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
STORAGE/SUPPORT
SECURITY
VACANT
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
TOTAL 282.38 66,925 159,470
(237)
(237)
(237)
(237)
(237)
(0)
DIFFERENCE
220,363
0.72
TOTAL GSF
NET TO GROSS RATIO
10,765
1,445
4,740
4,740
14,813
3,220
4,495
12,499
39,755
Arts & Crafts Gymnasium Miscellaneous Recreation Multipurpose Room Pool Hall Recreation Office Recreation Storage Student Store Weight Room
Medical/Dental
Administration
Operations & Maintenance Warehouse
SECURITY
Vacant
6.10
8,400 1,100
1,995
2,015
3,220
4,495
9,857 2,642
39,755
1,445
4,740
1,896 2,844
1,775
-245
7,961 -202
-436
RESIDENT
NON-RESIDENT
(206)
(31) 15
50 10,300
4,048
1,775
-245
7,759
-436
39,755
92,545
Net Square Footage By Building Date: 04/06/2022 Page: 1
Center: GRAFTON (00104) of 4
HOUSING
Sleeping excl. SPD
Lounge
Storage
Shower/Toilet
Other
Function Suggested
NSF
19,600
7,120
3,190
3,680
2,550
0017 - DORM/ADMIN/MED/DENT
0017 - DORM/ADMIN/MED/DENT
0017 - DORM/ADMIN/MED/DENT
0017 - DORM/ADMIN/MED/DENT
0017 - DORM/ADMIN/MED/DENT
Bldg Name Actual NSF Difference
19,600
7,120
3,190
3,680
2,550
Sub Total: 36,140
14,832
2,060
1,236
2,472
1,648
22,248
4,768
5,060
1,954
1,208
( 206
13,892 rooms; beds
Page: 2
Center: GRAFTON (00104) of 4
EDUCATION
Academic
Vocational Theory (172)
Carpentry
Electrical
Plumbing
Health Occupations
Culinary Arts
Medical Assistant
Security Services
Non-Academic
Function Suggested
NSF
1,750 1,200
2,500 1,500
4,095
2,130
2,810
5,000
1,675
5,000
1,985
0009 - BASIC EDUCATION
0009 - BASIC EDUCATION
0009 - BASIC EDUCATION
0009 - BASIC EDUCATION
0008 - CONSTRUCTION TRADES
0008 - CONSTRUCTION TRADES
0016 - STORAGE
0008 - CONSTRUCTION TRADES
0015 - STORAGE
0008 - CONSTRUCTION TRADES
0015 - STORAGE
0001 - PINES A HEALTH & BUSINESS CLERICAL
0026 - CULINARY ARTS/CPP
0007 - VOCATIONS/LOGISTICS/WAREHOUSE/MAINT
0001 - PINES A HEALTH & BUSINESS CLERICAL
0002 - PINES B RECREATION
0009 - BASIC EDUCATION
0001 - PINES A HEALTH & BUSINESS CLERICAL
0001 - PINES A HEALTH & BUSINESS CLERICAL
0026 - CULINARY ARTS/CPP
0002 - PINES B RECREATION
0001 - PINES A HEALTH & BUSINESS CLERICAL
0009 - BASIC EDUCATION
0009 - BASIC EDUCATION
0007 - VOCATIONS/LOGISTICS/WAREHOUSE/MAINT
0009 - BASIC EDUCATION
Bldg Name Actual NSF Difference
4,245
4,000
4,895
2,530
2,810
5,000
2,595
11,303
Sub Total: 38,868
2,370
1,720
2,250
2,400
1,200
1,200
1,800
1,050
2,370
17,260
1,875
-940
1,750
2,495
1,330
1,610
3,200
1,695
-340
8,933
( 237
21,608
Page: 3
Center: GRAFTON (00104) of 4
FOOD SERVICE
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
Dining (2 Servings)
Food Preparation
Food Storage
Multipurpose Room
Arts & Crafts
Gymnasium
Weight Room
Student Store
Miscellaneous Recreation
Pool Hall
Recreation Storage
Recreation Office
Medical/Dental
Administration
Function Suggested
NSF
5,365
3,035
1,005
8,400
2,015
1,100
1,995
3,220
4,000
0025 - CAFETERIA
0025 - CAFETERIA
0025 - CAFETERIA
0002 - PINES B RECREATION
0002 - PINES B RECREATION
0018 - GYMNASIUM
0002 - PINES B RECREATION
0002 - PINES B RECREATION
0002 - PINES B RECREATION
0002 - PINES B RECREATION
0002 - PINES B RECREATION
0002 - PINES B RECREATION
0017 - DORM/ADMIN/MED/DENT
0007 - VOCATIONS/LOGISTICS/WAREHOUSE/MAINT
0017 - DORM/ADMIN/MED/DENT
Bldg Name Actual NSF Difference
5,365
3,035
1,005
8,400
2,015
1,100
1,995
3,220
4,495
Sub Total:
Sub Total:
Sub Total:
Sub Total:
9,405
14,813
3,220
4,495
1,896
1,422
1,445
4,740
4,266
10,765
1,445
4,740
3,469
1,613
1,775
-245
5,139
4,048
1,775
-245
Page: 4
Center: GRAFTON (00104) of 4
STORAGE/SUPPORT
SECURITY
VACANT
Warehouse
Operations & Maintenance
SECURITY
Vacant
Function Suggested
NSF
2,642
1,150
8,232
3,095 4,705
13,750 6,410 2,920 4,000 4,875
0007 - VOCATIONS/LOGISTICS/WAREHOUSE/MAINT
0015 - STORAGE
0001 - PINES A HEALTH & BUSINESS CLERICAL
0007 - VOCATIONS/LOGISTICS/WAREHOUSE/MAINT
0014 - GATE HOUSE/SECURITY
0006 - FORMER CULINARY ARTS (VACANT)
0010 - FORMER EDUCATION (VACANT)
0006 - FORMER CULINARY ARTS (VACANT)
0013 - FORMER OFFICE SPACE (VACANT)
0001 - PINES A HEALTH & BUSINESS CLERICAL
0007 - VOCATIONS/LOGISTICS/WAREHOUSE/MAINT
0002 - PINES B RECREATION
Bldg Name Actual NSF Difference
2,642
9,857
39,755
Sub Total:
Sub Total:
Sub Total:
12,499
39,755
2,844
1,896
4,740
-202
7,961
-436
39,755
7,759
-436
39,755
Environmental Management Report
Center: GRAFTON (00104) Page: 1 Date: 04/06/2022 of 1
SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)
Commercial Waste Service
HAZARDOUS MATERIALS STORAGE (EPCRA)
No Building 7
Organic solvent (55 gallons) Yes
PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)
N/A0
PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)
ASBESTOS AND PCB MANAGEMENT (TSCA)
AIR POLLUTION CONTROL (CAA)
All buildings have non-permitted gas boilers Minor Source - Exempt
Non-Attainment
Solid Waste Disposal :
Hazardous Waste Generator :
Hazardous Waste ID :
Generator Classification :
Hazardous Materials Storage :
Hazardous Materials ID :
HazMat Storage Area :
HazMat Spill Response Plan :
Number of Regulated USTs :
Number of Un-regulated USTs :
Local Hazardous Use Permit :
LEPC Notification :
EPA Generator ID Number :
Hazardous Waste Disposal :
RCRA Compliance :
Near building # 7
Near building #7
Near building #7
20,000
20,000
20,000
Petroleum - Heating Oil
Petroleum - Heating Oil
Petroleum - Heating Oil
ID LocationFuel Type Capacity
Number of ASTs :
Asbestos Survey Date :
Asbestos Type :
Asbestos Coordinator :
Coordinator Training Date:
Custodial/Maintenance Training :
Management Plan Approval :
PCB Transformer Testing :
PCB Transformers :
PCB-Contaminated Transformers :
Transformers Labelled :
Regional Air Quality :
Permitted Air Pollution Source :
Source Description :
Waste Services, Inc.
Yes Organic solvent (55 gals/month)
Conditionally Exempt Small Quantity Generator N/A Commercial Hazardous Waste Disposal Service Information not provided
No No
Overfill Leak Corrosion
SPCC Plan Required : SPCC Plan Completed :
Yes No
07/21/2000 Friable/Non-Friable Dan Block
No N/A
No
No
CO, Ozone
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
ID Fuel Type Capacity Location Overfill
Prevention Secondary ContainmentTank Status
Abandoned
Abandoned
Abandoned
Tank Status Prevention/Detection
Asbestos-Containing Materials Inventory
Date: 04/06/2022Center : Grafton (00104) Page: 1 of 2
Floor Finishes Floor Finishes Heating Floor Finishes Floor Finishes
Floor Finishes Floor Finishes Floor Finishes Floor Finishes Floor Finishes Floor Finishes Floor Finishes Floor Finishes
Floor Finishes Floor Finishes
Floor Finishes
Water Plumbing Floor Finishes Floor Finishes
Bldg System
Bldg System
Bldg System
Bldg System
Bldg System
9x9 floor tile Mastic beneath 9x9 tile Pipe insulation, air-cell Mastic beneath 9x9 tile 9x9 floor tile
9x9 floor tile (covered) Mastic beneath 9x9 tile Mastic beneath 9x9 tile 9x9 Floor tile, grey/white Mastic beneah 12x12 tile Mastic beneath 9x9 tile 9x9 Floor tile (covered) 12x12 floor tile
9x9 floor tile, green Mastic beneath 9x9 tile
12x12 floor tile (covered)
Pipe insulation Mastic beneath 9x9 tile 9x9 floor tile (covered)
Category Description
Category Description
Category Description
Category Description
Category Description
Sq. Ft.
Sq. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Location
Location
Location
Location
Location
Unit
Unit
Unit
Unit
Unit
Quantity
Quantity
Quantity
Quantity
Quantity
1st floor 1st floor Sub-basement 2nd floor 2nd floor
2nd fl., north hall 2nd fl., north hall 2nd fl. stairwell 2nd fl. stairwell 1st floor hallway Health services area Health services area 1st floor hallway
Basement storage rm.
Basement storage rm.
1st floor restroom
Plumbing chases Ground/1st floors Ground/1st floors
Building :
Building :
Building :
Building :
Building :
0001 - PINES A HEALTH & BUSINESS CLERICAL
0002 - PINES B RECREATION
0007 - VOCATIONS/LOGISTICS/WAREHOUSE/MAINT
0008 - CONSTRUCTION TRADES
0009 - BASIC EDUCATION
Asbestos-Containing Materials Inventory
Page: 2 of 2
Floor Finishes Floor Finishes Floor Finishes Floor Finishes Heating Heating
Heating
Heating
Bldg System
Bldg System
Bldg System
9x9 floor tile Mastic beneath 9x9 tile 9x9 floor tile Mastic beneath 9x9 tile Pipe insulation Pipe insulation
Pipe insulation
Pipe insulation
Category Description
Category Description
Category Description
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Lin. Ft.
Lin. Ft.
Sq. Ft.
Location
Location
Location
Unit
Unit
Unit
Quantity
Quantity
Quantity
Stairwell, east wing Boiler room Boiler room Stairwell, east wing 1st floor ceilings Basement crawlspace
Sub-basement tunnel
Steam tunnels
Building :
Building :
Building :
0010 - FORMER EDUCATION (VACANT)
0013 - FORMER OFFICE SPACE (VACANT)
SITE
Radon
Page: 1 of 1
0001 - PINES A HEALTH & BUSINESS CLERICAL
0002 - PINES B RECREATION
0006 - FORMER CULINARY ARTS (VACANT)
0007 - VOCATIONS/LOGISTICS/WAREHOUSE/MAINT
0008 - CONSTRUCTION TRADES
0009 - BASIC EDUCATION
0010 - FORMER EDUCATION (VACANT)
0013 - FORMER OFFICE SPACE (VACANT)
0014 - GATE HOUSE/SECURITY
0015 - STORAGE
0016 - STORAGE
0017 - DORM/ADMIN/MED/DENT
0018 - GYMNASIUM
0025 - CAFETERIA
0026 - CULINARY ARTS/CPP
Bldg Name
03/18/1991
08/18/1992
03/18/1991
03/18/1991
03/18/1991
07/09/2007
03/18/1991
07/09/2007
Test Date
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
N/A
Yes
No
No
No
Radon Testing
< 4 pCi
4 - 20 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
Test Result
N/A
N/A
No
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mitigation Mitigation Date
RADON EXPLANATORY NOTES
The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than
4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.
Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;
(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.
Site Description GRAFTON Job Corps Center
Aerial view of Grafton JCC
Site Description
Page: 1 Date: 04/06/2022 of 5
Comments:
Paving Type for Roads & Parking
Paved areas are deteriorated and need repaving. Approximately 1/2 of the sidewalks are deteriorated, cracking and becoming trip hazards. This is due to the extreme winter weather.
Paving Type for Sidewalks
Asphalt Concrete
Comments:
Topography Buildings and Structures
Center is not fully enclosed by fencing. The chain link fencing encompasses most of the site and separates deteriorated Buildings 3, 4, and 5 that are not used by the Center. The main entry area near Building 14 is not fenced.
ROADS, PARKING & SIDEWALKS
Water Source Water Authority Service Meter On-Site Treatment Plant
1. Water System
Treatment Type Storage Type Storage Capacity(Gallons)
NoMasterGrafton Water DistrictPublic Water Authority
None 0None
Water supply to the Center, from the Town of Grafton, is provided by one dead end 10" line. Water distribution on the site is with a looped system.
Comments:
Fire Hydrants On-Site Water Supply Storage Capacity
(Gallons) Pressure Source FD Response Time
(Minutes)
Yes 0 10None Municipal
Number of Deficiencies = 3
Number of Deficiencies = 3
SITE FEATURES
UTILITIES
2. Fire Protection System
Buildings Structures15 19Terraced
Surrounding
Outdoor Recreation
Forest, Light Commercial
Field, Soft/Baseball RR Tracks, Smoke Stacks
Most Of The Site Chain Link
Location Type
Maintenance Responsibility System Capacity Adequate System Condition
Utility Utility Yes Good
Separate Loop
No
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Utility Utility Yes Good
Ownership
Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition No Fair Yes Fair
Fencing
Other Features
Page: 2 Date: 04/06/2022 of 5
Comments:
Sewage Treatment Flow
Sewage flows through an 8" PVC sewer line by gravity to a lift station near Building 8. From the lift station, it is pumped through a force main to a siphon structure, owned by the Town of Grafton, located east of Building 4.
Sewage flows from this point under the railroad tracks to a 15" diameter gravity sewer off site. Reported by Green International Affiliates, Inc., May 14, 1998, and confirmed by successive facility surveys.
Utility
Publicly Owned Treatment Works
Center
Gravity and Lift Stations
Maintenance ResponsibilityOwnership
Eversource/Sprague
3. Sanitary Sewer System/ Sewage Treatment Plant
5. Fuel Distribution System
System Capacity Adequate System Condition
Yes Good
4. Storm Water System
Drain Type On-Site Storm Water Management
Surface Run-off N/A
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Lessor Yes GoodCenter
Comments: Storm water system is comprised of catch basins, underground drain lines, surface drainage, and concrete gutters.
Gas Company Metering
Individual
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Utility Utility Yes Good
6. Central Plant: None
Page: 3 Date: 04/06/2022 of 5
Comments:
Electric Company PCB Trans.
Transformer Mounting Transformer Ownership
Systems Ownership Maintenance Responsibility
Direct Energy
The overhead primary power lines located along the railroad at the Center’s southern perimeter provides the power to the Center at three locations. The first service point is from the pole with a fuse cutouts, located outside Vocations/Logistics/Warehouse/Maintenance Building 7. The power lines are terminated in a 4.16 kV, 600A, seven-bay high voltage switchgear (HV SWGR) in the basement of Building 7. Bays 6 and 7 of the HV SWGR are meter section and main section respectively. Bays 1, 2, 3, 4 and 5 are distribution sections with the following arrangements: Bay-1 serves Building 8 via a 75 kVA transformer. Bay-2 serves Building 7 via a 112.5 kVA transformer. Bay-3 serves Building 2 via a 200A/2.4 kV switch and a 225 kVA transformer. Bay-4 serves Building 17 via a 500 kVA transformer. Bay-5 serves both Building 1 and Building 6. One feeder from Bay-5 terminates in Building 1’s 200A/2.4 kV switch and the associated 500 kVA transformer. Another feeder from Bay-5 terminates in a 500 kVA transformer, located in Building 6. Buildings 9, 10 and 14 are sub fed from Building 6. Buildings 8A, 15 and 16 are sub fed from Building 8. Building 18 is sub fed from Building 2. The second service point is from the pole located southeast of Vacant Building 13, with a fuse cutouts and terminates in a 75 kVA step-down transformer located in Building 13 basement. The third service point is from the pole with two cutout fuses, located northeast of Cafeteria Building 25 and Culinary Arts/CPP Building 26. One riser terminates in the nearby 300 kVA pad-mounted transformer that serves Building 25. The other riser terminates in the nearby 225 kVA pad-mounted transformer that serves Building 26. A 200 kW standby diesel-engine generator located outside Building 17 provides backup power to critical loads in Building 17 via a 400A manual transfer switch (MTS) located inside the building. Another 24 kW standby diesel-engine generator located outside Construction Trades Building 8 provides backup power for sewage pumps via a 100A automatic transfer switch (ATS) installed next to the generator. A single meter located on Pine Street provides metering for the entire Center except Building 26, which has its own meter. Dorm/Admin/Med-Dental Building 17 and Gymnasium Building 18 have lightning protection system installed on roof.
Pad Center
Center Center
No
2,300V, 3-Phase, 3 Wire
208/120V, 3-Phase, 4 WireUnderground
Overhead & UndergroundPrimary Service
Secondary Service
Distribution Characteristics
Number of Deficiencies = 17. Electrical (Service)
Transformer Maint Resp
Center
System Capacity Adequate System Condition
Yes Fair
Generator
Diesel
8. Electrical (Site Lighting)
Roadways Parking Walkways Building Outdoor Sports
Mounting
Control
Pole Pole Pole Building Pole
Photocell, Time Clock Time Clock Photocell, Time Clock Photocell, Time Clock Switch
System Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
Comments: The site lighting, including pole-mounted and building-mounted exterior light fixtures, is controlled by photocell and time clock via lighting contactor located in the building within the vicinity of the pole-mounted lights. Culinary Arts/CPP Building 26 has LED exterior lights. The center had recently replaced three pole lights at the trail leading to the ballfield with light emitting diode (LED) lights. The Center owns and maintains the site lighting.
ATS MTS
Yes Yes
Metering Master
Page: 4 Date: 04/06/2022 of 5
Comments:
Telephone Company
On-site Line Owner
Verizon provides telephone service with five T1 lines that terminate in Telephone Room 112 located in Building 17 medical/dental area. This is the demarcation point where Center-owned telephone and data/communication equipment is located. Job Corps Data Center (JCDC) installs, manages and maintains the internal data/communication distribution systems, which include analog telephone, internet and digital voice over internet protocol (VoIP). Network connections between the server and buildings are via fiber optic cabling and IC box located in each respective building. The server room has a 6 kVA uninterruptable power supply (UPS) module as backup power for 20 minutes. Local fire alarm panels provide detection and notification within respective buildings. JCDC had recently installed several new closed circuit television (CCTV) cameras Center wide. JCDC can monitor the cameras on-line 24/7. The Center can monitor the cameras from the Gatehouse/Security Building 14 and Dorm/Admin/Med-Dental Building 17. Motion sensors and local security panels provide detection in the respective buildings and are connected to the exterior located sirens. Door hardware with door alarms are installed at the dormitory wing exits. Cable TV is located in the data closet in Building 17, where it is distributed to Dormitory Building 17, Pines B Recreation Building 2 and Cafeteria Building 25.
Verizon
Maint. Responsibility
Center Center
Motion detectors are provided at selected locations.
Unknown
Unknown
Unknown
Lessor
Lessor
Lessor
Abandoned
Abandoned
Abandoned
Underground, Non-regulated
Underground, Non-regulated
Underground, Non-regulated
Near building # 7
Near building #7
Near building #7
All underground storage tanks have been closed-in-place in accordance with State and Federal closure guidelines.
No
No
No
Petroleum - Heating Oil
Petroleum - Heating Oil
Petroleum - Heating Oil
STORAGE TANKS
Comments:
TypeStatus Location Owner Fuel Type Capacity (Gallons) Install DateID
Reg.
20000
20000
20000
9. Electrical (Communication/Alarm/Security)
Heating
Heating
Heating
Purpose
Yes
Stand-Alone
VOIP
System Capacity Adequate System Condition
FairYes
Number of Deficiencies = 4
Fire Alarm Security
Page: 5 Date: 04/06/2022 of 5
ACCESSIBILITY
Yes
Comments:
UnknownYesYes
The complex was a former Massachusetts State Mental Hospital that was established in 1905.
Yes
Nationally Registered Site
Site Eligible for National Register
Located in Historic District
Archaeological Significance
Earthquake Risk
Medium Low MediumHigh LowIBC Low
LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest
Fire
Number of Deficiencies = 1
Accessible Parking: Accessible Slope:
No
Curb Cuts:
Yes
Ramps:
NoNo
Site Accessible Route:
GENERAL SITE CONDITION
Rating X
Good Fair Poor
There is some road and hillside erosion. There are some drainage problems as well. The site is attractive with large trees, landscape plantings and wooded surroundings. The roads and sidewalks are deteriorated.
HISTORIC PRESERVATION
NATURAL HAZARDS
The site condition is not impacting the functional use of the facilities.
The site condition IS impacting the functional use of the facilities.
The site condition IS SIGNIFICANTLY impacting the functional use of the facilities.
Active Energy Use Reduction Program
Active Water Use Reduction Program
Approximate or Measured Waste Recycled
Use of School Dude or CMMS for Preventative Maintenance
Green Purchasing Policy Practiced
Site Stormwater Absorption Measures in Place
Center has Onsite Renewable Energy (PV or Wind)
Center has a Chartered Green Committee & Roster
Center Uses Green Cleaning Practices
SUSTAINABILITY
Yes
Yes
NO
NO
Yes
Yes
Yes
Yes
25 %
Building Descriptions and Structures
BUILDING 1 - PINES A HEALTH & BUSINESS CLERICAL
MECH
ELEC
ROOM
T
ELEV.
ELEVATOR
EQUIPMENT
TECH.
DATA
ROOM
STAFF TRAINING ROOM
STORAGE
STORAGE
COUNSELING
STORAGE
STORAGE
STORAGE
VACANT
40 Feet20'0
GRAFTON JOB CORPS CENTER
North Grafton, Mass
10'
PINES A HEALTH & BUSINESS
CLERICAL
BUILDING 1
BASEMENT
NON-ACADEMIC
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
M
W
ELEV.
ELEVATOR
MACHINE ROOM
WBL
CTR 2
CTR 1
J
COPY/
ADMIN
CTS
TRADE MGR
GUIDANCE
COUNSELOR
GUIDANCE
COUNSELOR
OA/CTS DIRECTOR
40 Feet20'0
GRAFTON JOB CORPS CENTER
North Grafton, Mass
10'
PINES A HEALTH & BUSINESS
CLERICAL
BUILDING 1
FIRST FLOOR
VOCATION/THEORY
NON-ACADEMIC
ADMINISTRATION
AutoCAD SHX Text
HC
AutoCAD SHX Text
HC STALL
AutoCAD SHX Text
HC STALL
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text
UP
STORAGE
CNA
STORAGE
OFFICE
CNA
MEDICAL
ASSISTANT
LABORATORY
W
CNA
TRAINING
BATHROOM
CTS CTS
STORAGE
STORAGE
40 Feet20'0
GRAFTON JOB CORPS CENTER
North Grafton, Mass
10'
PINES A HEALTH & BUSINESS
CLERICAL
BUILDING 1
SECOND FLOOR
VOCATION/THEORY
AutoCAD SHX Text
DN
DN
Building Descriptions
Page: 1 of 80
Building: 0001 - PINES A HEALTH & BUSINESS CLERICAL
BUILDING ENVELOPE
Foundation RoofBuilding
Stone Masonry Loadbearing Masonry Wood
The lower level floor is concrete slab on grade.
Brick Masonry Stone Masonry
Comments: The wall system is comprised of stone at the lower floor and brick on the upper levels. Water seeps through the exterior stone wall.
Wall Roof None None
Metal Unit with Glazing - Metal Frame Wood Unit - Wood Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
B 14,475 10,164 3 Leased 1905 Contributing
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 2
Insulation4.
Exterior Doors5.
Material
The remaining roof life expectancy is based on visual observation, installation year, and condition of the roof during the 2021Facility Survey
Drainage Year Life
Type Area Served
Asphalt Shingles Surface Run-off 2001 1 Hip Entire Building
Number of Deficiencies = 1
Comments:
3. Roof
Entire Building
Area Served
Comments:
Page: 2 of 80
Building: 0001 - PINES A HEALTH & BUSINESS CLERICAL
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile Wood
Brick Drywall Plaster Stone
Metal Unit - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
Concrete Stairs (exterior and interior) Elevator
Double Hung - Vinyl Frame; Double Glazing; Fixed - Metal Frame; Double Glazing;
Single Hung - Aluminum Frame; Double Glazing;
Acoustical Tile Exposed Structure Gypsum Board Plaster
Number of Deficiencies = 1
Windows6.
Floors1. Asbestos: Yes
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The boiler was built by Burnham (1673 MBH input) and is furnished with a Taco circulator (#121A3N1, 1/3 HP) and two Taco hot water pumps (3 HP) that circulate hot water to the 32 fan coil units.
Additional heating is provided in the two stairwells and women's restroom by hot water convectors. A Carrier air handling unit (#39MN06B) delivers tempered OA to the fan coils.
These units serve stairwells and restrooms.
Comments:
Comments:
HVAC
Heat1. Asbestos: Yes
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Fan Coil
Baseboard Convector
Two-Pipe
Two-Pipe
Electric
Electric
Mechanical
Natural
None
None
Entire Building
Common Area
Ceilings
Page: 3 of 80
Building: 0001 - PINES A HEALTH & BUSINESS CLERICAL
Mechanical Restroom
The water heater (Bradford White #LD50S33C110, 50 gallon, 11 kW) is located in the basement mechanical equipment room.
Comments:
Cast Iron None None
Electric Water Cooler Hose Bibb Lavatory Mop Sink Service Sink Shower/Bathtub Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: The former wet fire standpipe and sprinkler systems are abandoned in place.
Ventilation Area Served
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Chiller Fan Coil Two-Pipe Electric Mechanical None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
An air-cooled chiller (Carrier #30RAN040, 37 ton, scroll, R-22, mfd. 10/2004) produces cooling for the building. Two Taco pumps (#FI1509E2) circulate chilled water to the 32 fan coil units. An air handling unit (Carrier #39MN06B, mfd. 3/2004) located in the basement mechanical equipment room delivers tempered OA to the larger rooms.
Comments:
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
3. Air Conditioning
Page: 4 of 80
Building: 0001 - PINES A HEALTH & BUSINESS CLERICAL
Comments: Service is brought from Bay-5 in the high voltage switchgear (HV SWGR) located in Building 7 basement. Service terminates in a 200A/2.4 kV main metal enclosed disconnect switch, rated at 5 kV, with a fuse rating 100E, located in Building 1 basement electrical room. The switch feeds a 500 kVA pad-mounted transformer located in the back of the building. The transformer supplies power to a 1200A, 120/208V two-section switchboard located in the basement electrical room. The main section has a 1200A switch; the distribution has (5) 200A, (2) 100A switches and (2) spaces. One 100A switch is a spare and the rest of the switches serve all loads in the building.
FIRE ALARM
Comments: The fire alarm panel is a Notifier NFS-640, located at the first floor vestibule.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Comments: Recorded footcandle levels include natural light contribution. T8-fluorescent lighting is utilized at the first and second floors of the building, renovated at 2006. T12-fluorescent lighting is utilized only in the vacant areas at the basement level.
Comments: Selected fluorescent light fixtures with battery backup are utilized in the corridors and classrooms.
High Intensity Discharge (HID) Incandescent Lights Comments: Building-mounted and pole-mounted site lighting is controlled by a photocell and a time clock.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T12 - Fluorescent
Offices
Conference Rooms
Equipment Rooms (Elec/Mech)
Toilets
Storage Rooms
Classrooms
Vacant
N/A
Area Recommended Recorded Light Type
Battery Backup Battery Backup
Main Disconnect Switch 120/208V, 3-Phase, 4 Wire Switchboard Receptacles, GFCI, Switches
Emergency Exit
Number of Deficiencies = 1
ELECTRICAL SERVICES Number of Deficiencies = 2
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
Type Location 120V w/Battery Backup Mechanical Room
CARBON MONOXIDE DETECTION
LIGHTING
Detection Required No
Number of Deficiencies = 1
Page: 5 of 80
Building: 0001 - PINES A HEALTH & BUSINESS CLERICAL
Comments: The building is connected to the center's LAN system. The building has surveillance cameras installed on both exterior and interior. Motion detectors are connected to a local security alarm system reporting to a keypad security panel.. A siren for the security system is mounted on the building exterior, and an annunciator panel is provided in the first floor vestibule. The data room has one 6500 Cisco Catalyst switch (WAN) and one 1700 Cisco Catalyst switch (Ethernet).
Connected to Main System Closed Circuit TV None TV with VCR
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
Chiller has failed. All HVAC controls are disconnected and operated manually and inefficiently.
Electrical transformer was not properly installed. Water is seeping through the exterior foundation walls.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoNo
BUILDING UTILITY METERING
Structure: Good Exterior: Fair Interior: Good Mechanical: Poor Electrical: Good
IMPAIRMENT
Potentially Impaired
DOL Responded
DOL Determination
Potential Impaired Comments DOL Determination Discussion/Comments
BUILDING 2 - PINES B RECREATION
ELEC
BOILER ROOM
ELEVATOR
EQUIPMENT
ELEVATOR
DN
UP
UP
UP
UP
UP
MECH
TEL/COM
STOR.
BUILDING 2
PINES B RECREATION
10'
North Grafton, Mass
GRAFTON JOB CORPS CENTER
0 20' 40 Feet
BASEMENT
VACANT
STORAGE/SUPPORT
D N
U P
D N
D N
D N
U P
D N
D N
D N
W
M
TECH LAB
ARTS AND CRAFTS
OFFICE
CSIO
INCENTIVE
CLOSET
JAN
ELEC
POOL/RECREATION
ROOM
STORAGE
CSIO SUPERVISOR
(CENTER STANDARDS
INCENTIVE OFFICER)
CONNECTOR TO
GYMNASIUM
(BLDG.18)
SOCIAL DEVELOPMENT
DIRECTOR
ARTS AND CRAFTS
STORAGE
STOR.
STOR.
BUILDING 2
PINES B RECREATION
10'
North Grafton, Mass
GRAFTON JOB CORPS CENTER
0 20' 40 Feet
RECREATION
FIRST FLOOR
ADMINISTRATION
VOCATION/THEORY
NON-ACADEMIC
ROOF
LEADERSHIP TRAINING
(SGA)
JAN
UP
DN
ELEVATOR
STOR/ELEC.
DN
M
MALE
WEIGHT ROOM
ELEC
SUPPLY ROOM
SOCIAL
DEVELOPMENT
ADMIN
STUDENT
STORE
STORAGE
SOCIAL
DEVELOPMENT
ADMIN. ASSIST.
BUILDING 2
PINES B RECREATION
10'
North Grafton, Mass
GRAFTON JOB CORPS CENTER
0 20' 40 Feet
SECOND FLOOR
NON-ACADEMIC
RECREATION
Page: 6 of 80
Building: 0002 - PINES B RECREATION
BUILDING ENVELOPE
Foundation RoofBuilding
Stone Masonry Loadbearing Masonry, Steel
Wood
Brick Masonry Stone Masonry
Comments: There is no insulation on the basement walls.
Wall Roof None Batt
Metal Unit - Metal Frame Storefront - Storefront Frame Wood Unit - Wood Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
A-3 21,750 12,163 3 Leased 1905 Contributing
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4. Number of Deficiencies = 1
Exterior Doors5.
Material
The remaining roof life expectancy is based on visual observation, installation year, and condition of the roof during the 2021 Facility Survey. The roof is leaking.
Drainage Year Life
Type Area Served
Asphalt Shingles Surface Run-off 2000 0 Hip Entire Building
Number of Deficiencies = 1
Comments:
3. Roof
Entire Building
Page: 7 of 80
Building: 0002 - PINES B RECREATION
INTERIOR FINISH
Carpet Ceramic Tile Concrete Earth Rubber Tile Terrazzo Vinyl Tile Wood
Ceramic Tile Drywall Paneling Plaster
Metal Unit - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
Concrete Stairs (exterior and interior) Elevator
Double Hung - Wood Frame; Double Glazing; Fixed - N/A Frame; Glass Block Glazing;
Acoustical Tile Exposed Structure Plaster
Windows6.
Floors1. Asbestos: Yes
Interior Walls2.
3.
Interior Doors4.
Page: 8 of 80
Building: 0002 - PINES B RECREATION
Mechanical
Mechanical
Restroom
Janitor's Closet
Comments: The two in-line fans are located in the attic.
Ventilation Area Served
Chiller
Chiller
Fan Coil
Single Duct
Two-Pipe
Two-Pipe
Electric
Electric
Natural
Mechanical
None
None
Recreation Area
Recreation Area
Exhaust Ventilation
Chilled water is produced by a McQuay air-cooled chiller (#AGZ055AS42, 50 ton) and circulated to 35 fan coil units (Carrier) throughout the building by two pumps (Taco, 5 HP).
Two air handlers (McQuay #CAH006FDAC) in the attic serve 100% outdoor air to the first and second floor spaces. This air is cooled by the chilled water system and each AHU is equipped with a circulating pump (Taco #1611C3N1, 1/4 HP).
Comments:
Comments:
Number of Deficiencies = 2
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heat is produced by a Weil-McLain unit (#788, 1419 MBH output) and circulated through the boiler by two pumps (Taco, 1-1/2 HP) and circulated to 35 fan coil units (Carrier) throughout the building by two pumps (Taco, 5 HP).
Two air handlers (McQuay #CAH006FDAC) in the attic serve 100% outdoor air to the first and second floor spaces. This air is heated by the hot water system and each AHU is equipped with a circulating pump (Taco #1611C3N1, 1/4 HP).
Additional heating is provided by hot water unit heaters by Rosemex (basement, #H58 and attic, #H80) and convectors (restrooms and basement).
There is an electric unit heater in the basement electrical room.
Comments:
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Electric Resistance
Fan Coil
Single Duct
Unit Heater
Unit Heater
Two-Pipe
Two-Pipe
Two-Pipe
None
Electric
Electric
Electric
Electric
Natural
Mechanical
Natural
Natural
None
None
None
None
Entire Building
Entire Building
Entire Building
Equipment Room
Ventilation2.
System Type
Number of Deficiencies = 1
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
3. Number of Deficiencies = 1Air Conditioning
Page: 9 of 80
Building: 0002 - PINES B RECREATION
The heater was built by Rheem (#ES8518G, 85 gallon, 18kW).Comments:
Comments:
Cast Iron None None
The service sink in the arts and crafts room is furnished with a solid waste interceptor.
Electric Water Cooler Hose Bibb Lavatory Mop Sink Service Sink Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: The former wet fire standpipe and sprinkler systems are abandoned in place.
Comments: Service is brought from Bay-3 in the high voltage switchgear (HV SWGR) located in Building 7 basement. Service terminates in a 200A/2.4 kV main metal enclosed disconnect switch (5 kV, fuse rating 100E) located in Building 2 basement electrical room. The switch feeds a 225 kVA transformer which in turn, supplies power to an 800A, 120/208V two-section switchboard. The main section has an 800A switch with ammeter and voltmeters. The distribution section has (4) 150A breakers serving four electrical panels, (1) 300A serving HVAC units, (1) 175A serving the elevator, (1) 70A serving the hot water tank, (1) 225A serving Gymnasium Building 18 and (1) 100A as spare. The HV SWGR in Building 7 also serves Buildings 1, 6, 7, 8 and 17
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
High Intensity Discharge (HID) Comments: Building-mounted site lighting is controlled by a time clock and a roof-mounted photocell through the lighting contactor located in the electrical room.
Main Disconnect Switch 120/208V, 3-Phase, 4 Wire Switchboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 2
Exterior Lighting1.
LIGHTING
Page: 10 of 80
Building: 0002 - PINES B RECREATION
FIRE ALARM
Comments: The fire alarm panel is a Notifier model NFS2-3030D located in the main electrical room. The panel also serves fire alarm devices and a annunciator panel in Building 18.
Comments: The building is connected to the center's LAN system. The building has surveillance cameras installed on both exterior and interior. Motion detectors are connected to a local security alarm system reporting to a key pad security panel (by Gemini). A siren for the security system is mounted on the building exterior. Speakers are also provided and currently are not in use.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System Closed Circuit TV Not Connected to Main System
Local Cable Company
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution. Pendant light fixtures and cove lighting are provided in the second floor multi-purpose room.
Comments: Selected cove light fixtures at the second floor weight room are also provided with emergency ballasts.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T12 - Fluorescent
Offices
Conference Rooms
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Toilets
Storage Rooms
Study Room
Recreation
Recreation
Storage/Warehouse-Active
Area Recommended Recorded Light Type
Selected Lighting w/ Battery Battery Backup
Emergency Exit
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
COMMUNICATION
Type Location 120V w/Battery Backup Mechanical Room
Directive Information Notice 12-27 and NFPA 720, 2012.
CARBON MONOXIDE DETECTION
Detection Required No
Page: 11 of 80
Building: 0002 - PINES B RECREATION
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
All exhaust fans are inoperable. Electronic HVAC controls have been abandoned. Two air handlers in the attic are inoperable due to freeze damage. The interior, floor mounted unit ventilators need replacement. There is no insulation on the basement walls, which is a concern since large water pipes are located in unheated or insulated basement spaces.
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas Yes YesNo
BUILDING UTILITY METERING
Structure: Good Exterior: Fair Interior: Fair Mechanical: Poor Electrical: Good
IMPAIRMENT
Potentially Impaired
DOL Responded
Page: 12 of 80
Building: 0006 - FORMER CULINARY ARTS (VACANT)
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete, Stone Masonry Loadbearing Masonry Wood
Brick Masonry
Wall Roof None Perlite, Blown
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
B 24,850 16,845 2 Leased 1905 Contributing
Comments: There is a ramp at the former queue line.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
No
Yes
Yes
Yes
No
No
No
N/A
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Material
The gutters and downspouts are extremely deteriorated or missing.
Drainage Year Life
Type Area Served
Slate
EPDM with Ballast
Gutters and Downspouts
Interior Roof Drains
Hip
Flat
Kitchen and Dining
Storage and Queue
Comments:
3. Roof
Entire Building
BUILDING 6 - FORMER CULINARY ARTS (VACANT)
CRAWL SPACE
BOILER
ROOM
UP
ELEC
MECH
UP
UP
UP
UP
UP
BUILDING 6
VACANT
BASEMENT
40 Feet20'0
GRAFTON JOB CORPS CENTER
North Grafton, Mass
10'
FORMER CULINARY ARTS
( VACANT)
T
T
Q
U
E
U
E
T
T
DN
T
DN
DN
DN
DN
DN
DN
BUILDING 6
FORMER CULINARY ARTS
( VACANT)
FIRST FLOOR
40 Feet20'0
GRAFTON JOB CORPS CENTER
North Grafton, Mass
10'
Page: 13 of 80
Building: 0006 - FORMER CULINARY ARTS (VACANT)
INTERIOR FINISH
Carpet Concrete Quarry Tile Rubber Vinyl Tile
Brick Drywall Fiberglass Reinforced Plastic Glazed Block Plaster Wood Panel
Metal Unit - Metal Frame Wood Unit - Wood Frame
VERTICAL CIRCULATION
Concrete Stairs (exterior and interior) Elevator Metal Ladder Comments: There is a vertical ladder to the attic mechanical equipment. The elevator is not in operation.
Metal Unit - Metal Frame
Double Hung - Wood Frame; Single Glazing; Sliding - Aluminum Frame; Single Glazing;
Acoustical Tile Plaster
Exterior Doors5.
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Two Weil-McLain gas-fired boilers (2713 MBH each) provide hot water for unit heaters. Three in-line pumps circulate the water throughout the building.
These units serve culinary arts spaces.
Comments:
Comments:
HVAC
Heat1. Number of Deficiencies = 1
Gas-Fired Hot Water Boiler
Electric Resistance
Unit Heater
Baseboard Convector
Two-Pipe
None
Electric
Electric
Natural
Natural
None
None
Entire Building
Classrooms and Offices
Page: 14 of 80
Building: 0006 - FORMER CULINARY ARTS (VACANT)
Mechanical
Mechanical
Mechanical
Restroom
Kitchen
Dining Hall
Comments:
Comments:
The kitchen hoods have associated utility set type exhaust fans located in the attic.
The dining hall is ventilated by an in-line exhaust fan located in the attic.
The heater was built by Raypack. A circulator (Taco, 1/6 HP) pumps water to two storage tanks (Rudd #RST1204, 115 gallon each). There is also an electric water heater (Rheem #GE50MBA, 50 gallon,
4.5 kW, built 01/03).
Comments:
Cast Iron/PVC/Copper Outdoor None
Fixed Emergency Eyewash Hose Bibb Lavatory Mop Sink Multi-Compartment Sink Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
Ventilation Area Served
Copper Copper Gas-Fired Building Water Softener Yes
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Split Direct Expansion (Air
Source)
Packaged Direct
Expansion (Air Cooled)
Fan Coil
Window Unit
Refrigerant
None
Electric
Electric
Natural
Mechanical
None
None
Common Area
Dining Hall
PLUMBING
Exhaust Ventilation
The split system serves the banquet room and the condensing unit (Ducane #AC10B60A, 5 ton) is on the roof.
Comments:
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Page: 15 of 80
Building: 0006 - FORMER CULINARY ARTS (VACANT)
None None ABC Type Fire Extinguisher, K Type Fire Extinguisher, Wet Chemical
Comments: Service is brought from Bay-5 in the high voltage switchgear (HV SWGR) located in Building 7 basement. Service terminates in a 500 kVA transformer located in Building 6 basement electrical room.
The transformer supplies power to a 1600A, 120/208V switchboard (SWBD). This SWBD serves Buildings 6, 9, 10 and 14. The SWBD has a 1600A main disconnect switch, (2) 225A, (2) 200A, (4) 150A,
(1) 125A, (1) 70A breakers and (2) spaces. The 70A, 125A and two other 150A breakers that serve the abandoned kitchen equipment in Building 6 have been turned off since the culinary arts vocation had been relocated to the new Culinary Arts/CPP Building 26. Two breakers, a 200A and a 150A, serve Building 10. A 100A breaker serves Building 14. The SWBD also feeds a 400A/240V disconnect switch that serves Building 9 via a step-up transformer (primary: 208V – secondary: 480/277V) and the associated secondary disconnect switches rated at 200A/600V. The HV SWGR in Building 7 also serves Buildings 1, 2, 7, 8 and 17.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
High Intensity Discharge (HID) Comments: Building-mounted site lighting is controlled by a time clock.
Main Circuit Breaker 120/208V, 3-Phase, 4 Wire Switchboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
FIRE PROTECTION
ELECTRICAL SERVICES
Exterior Lighting1.
Location UL300 Compliance Status Kitchen Non-Compliant
UL300 COMMERCIAL KITCHEN HOOD FIRE SUPPRESSION
Page: 16 of 80
Building: 0006 - FORMER CULINARY ARTS (VACANT)
FIRE ALARM
Comments: The fire alarm panel is a Silent Knight SK-5208 (06/2012) located in the culinary arts dining room. The panel is controll serves fire alarm devices only in the occupied area and in the basement mechanical and electrical rooms.
Comments: The building is connected to the center's LAN system.