BOC Industry Day Question and Answer Presentation (6-25-2024).pptx
PPTX presentation 3 MB Posted
- Solicitation number
- 1605-BOC-24-NAT-0160
About this file
This document is a Department of Labor (DOL) Request for Information (RFI) for Frances Perkins Building Facilities Operations and Maintenance Services. It announces an industry day on June 18, 2024 for a site visit and a virtual Q&A session on June 25, 2024. The RFI seeks information from industry on their capabilities to provide full-spectrum facilities operations, maintenance, and repair services as outlined in the draft Performance Work Statement (PWS). Key details include:
The DOL is conducting market research to determine feasibility for a potential future procurement. This RFI is not a solicitation. Respondents are asked to provide company information, staffing approach, subcontracting plans, repair process, and any concerns or feedback on the draft PWS. Capabilities statements are due by June 28, 2024. The NAICS code for this requirement is 561210 - Facilities Support Services. Questions must be submitted in writing by June 28, 2024. The RFI indicates potential base plus four option year pricing information is requested, but no specific budget estimates are provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Industry Day Questions and Answers.pdf | ||
| Sources Sought 6.10.24.pdf | ||
| Draft PWS-FPB OM and Repairs.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OASAM / BOC Vendor Industry Day RFI Q&A Conference
June 25, 2024
UNITED STATES DEPARTMENT OF LABOR
WELCOME
Introduction Today’s event is being hosted by the Office of the Senior Procurement Executive (OSPE), Office of Acquisition Services (OAS) and the Business Operations Center (BOC).
DOL Procurement Team Helen Williams, Contracting Officer Philip Ward, Contract Specialist Devon Mayers, Contracting Officer’s Representative
DOL’s Mission To foster, promote, and develop the welfare of the wage earners, job seekers, and retirees of the United States; improve working conditions; advance opportunities for profitable employment; and assure work-related benefits and rights.
INDUSTRY RFI Q&A OBJECTIVES
Educate prospective partners about the Frances Perkins Building (FPB) and the building’s infrastructure.
Provide an overview of the FPB layout and identify key components of the building’s infrastructure.
Engage industry through a question and answer (Q&A) format, refine the scope/tasks of the PWS based on the feedback gathered, and promote competition to the maximum extent practicable.
RULES OF ENGAGEMENT & OVERVIEW
Nothing said here today is binding unless issued via a solicitation This session is being recorded for Government use ONLY
Presentation Instructions:
Please place all microphones on mute Q&As will begin at the end of each segment (Building Structure, Mechanical system, and Electrical system) of the building presentation Questions can be submitted by using the chat feature, via email, or over the microphone 6/25/2024
Frances Perkins Building (FPB) Layout Floors 6, that consist of 1,851,000 Gross Square Feet
Constructed in 1974
Flooring consist primarily (95%) of an adhesive floor tiles that has an asbestos base adhesive
Ceiling tiles consist primarily (87%) of fissured panels, standard
Office doors are primarily 9ft wooden (95%) with mechanical keys
Walls are primarily drywall/gypsum (70%) or concrete material
Procurement and or Facility Q&A
MECHANICAL SYSTEM
Upper Roof - Penthouse (Chiller #9) North Penthouse – Fan Room (N Drinking Water Chiller, AHU-28) South Penthouse Fan Room (S Drinking Water Chiller, AHU-29) Lower Roof – Cooling Tower (3ea.) Deck Cafeteria area (Gas equipment) S6220 Mechanical Room (3ea. Steam PRV, AHUs 30-31-32-33-34-35-36-37-38-39-40-4-42-43-44 -51-52-53) Plaza Northeast - behind Vault Room (AHU-54) South Garage-Level B (UST Monitor) East Garage-Level B (AHUs 24-25) N2612 Northwest Mech Room (AHUs 01-02-03-04-05-06-07-08-21) N2709 Northeast Mech Room (AHUs 17-18-19-20) Elevators 31ea.
MECHANICAL SYSTEM (cont.)
Lower Main Mech Room 4ea. meters 6ea. Steam PRV 7ea. HW Steam converter 2ea. Air compressor 2ea. Air dryer 2ea. TWR Makeup Water Chiller #1 ,#2, and #3 Cooling Loop Water Treatment Heating Loop Water Treatment S0016 Loading Dock Mech. Room AHUs 45 C0048 AHUs 46-47-48-49 N0066 AHUs 09-10-11-12-13-14-15-16
ELECTRICAL SYSTEM
S6220 Mech Room 3ea. Generators with 3ea. Day tank Lower Main Mech Room- Primary Vault 4ea. Separate Feeders High Voltage Substation with TransXs & Tie Breakers Fountain Pump Fountain Skimmer Pump 4ea. Sump Pump East Garage-Level F (3ea. Sump Pumps) North Garage-Level F (2ea. Sump Pump) South Garage-Level F (2ea. Sump Pumps)
Closeout & Next Steps Helen Williams Branch Chief, Customer Acquisitions Services (CAS) Division 3 Devon Mayers Chief Engineer, Building Facility image1.png image2.png image3.png image5.jpeg image4.png