About this file

This document appears to be the Machine Dimensions and Specifications for the UT030E Dryer, which is relevant to a federal contract opportunity solicitation from the Federal Bureau of Prisons, Federal Correctional Complex in Florence, CO.

The solicitation, numbered 15B40624Q00000016, is for the acquisition of five (5) commercial dryers to be delivered to the Federal Correctional Complex in Florence, CO. The solicitation will be available on or about June 5, 2024 and responses are due by June 14, 2024 at 10:00 a.m. The contract will be a firm-fixed price award, with past performance considered approximately equal in value to price. Payment will be made using Electronic Funds Transfer or a Government Purchase Card. There is no set-aside for this acquisition. Key specifications for the UT030E Dryer include dimensions, airflow, static back pressure, and heating element rating.

View the file

Other files for this federal contract opportunity

Other files attached to FCC Florence Dryers FY 24, newest first.
File Type Posted
UT120L and UT120N.pdf PDF
WIP SOW Dryer details for solicitation.docx DOCX document
PDFRetriever.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Machine Dimensions and Specifications �c Model UT030E

Equipment specifications are subject to change without notice.

Machine Dimensions and Specifications

B

BACK

F

EXHAUST

exhaust far enough away from make-up air

G

----E---

Electrical Connection

1.375 in.

[35 mm]

K---+1

---L---

Make-up Air Opening (min. 12 in. [305 mm]

/away from vent -{ termination)

_j Exhaust airflow -location to prevent ...,__�

__ .L__ Max. duct length L)-_J __ �:i 14 tt. [4.3 mJ

.' ,,: re-introduction. _, Min. Clearance 24 in. [610 mm]

1-c�-+i-;.- Rec. Clearance 36 in. [914 mm]

Min. Clearanc.'"==::=========� T_�-:===l_ MBoth Sides of Duct 2 in. [51 mm] TMB122L_SVG

12-10-380

Design 6

Dimensions

A 26.3 [670] H 18.5 [470] B 27.5 [700] I 4.6 [115] C 28.4 [720] J 3.9 [100] D 31.8 [810] K 24.6 [625] E 45.5 [1,155] L 27.9 [710] F 63.9 [1,625] M 36 [910] G 33.2 [845] in.[mm]

Soecifications

Net Weight (approximate): Pounds [kg] 340 [155] Required Make-Up Air Opening (to the 110 [710] outside) for Each Tumble Dryer, in.2

[cm2]

Maximum Airflow: C.F.M. [I/sec] 500 [240] Maximum Static Back Pressure: Inch 0.80 [2.0, 0.20] W.C. [mbar, kPa] Heating Element Rating: Kilowatts 21

Electrical Soecifications

Cl) Cl) Cl) Cl) � Ill "C Cl u Ill 0. Cl)

0 "' "' i E

.II:

E

.. >, .c "' (.) D. <( f .§. Cl)

"C m Cl C) "' "' ::

.. 0

:::J i;g ...J u

Cl)

LI.

Cl) i

G 230-240 50-60 3 L1, L2,L3 52 70 4 [25] and ground

L 460-480 50-60 3 L1, L2,L3 27 35 8 [10] and ground