155 West Street Roof - Bid - Drawings 2026.06.22.pdf
PDF 7 MB Posted
- Solicitation number
- 2137484
- Issued by
- Orange County, New York
About this file
This is a set of architectural bid drawings for a roof replacement project at 155 West Street in Newburgh, New York, prepared by CPL (Architecture Engineering Planning) and issued for bid on June 22, 2026. The project, managed by the City of Newburgh under interim city manager Jason Morris, involves comprehensive roof renovation work including removal of the entire existing flat roof membrane, replacement of compromised roof sheathing and structural framing members, installation of new rigid insulation and a new 2-ply SBS-modified bitumen roofing system over the approximately 4,221 square foot flat roof area, installation of new equipment curbs and crickets for proper drainage, replacement of boot flashings around all roof penetrations, and installation of a new continuous ridge vent along the existing gable roof sections. The drawings indicate selective demolition requirements including removal of four deteriorated 16-inch AJS25 joists (approximately 23 feet in length), removal of existing EPDM roofing membrane and rigid insulation, and preparation of all roof penetrations for new flashing systems. A pre-bid site visit meeting is scheduled for Thursday, July 30, 2026, at 9:30 a.m., with contractor attendance strongly encouraged. The project is subject to New York State Building Code (2025), Energy Conservation Construction Code of New York State (2025), and all applicable local codes and regulations, classified as an Alteration—Level 1 with wind load design of 115 MPH (ASCE 7-16).
All work must comply with prevailing wage requirements, with contractors required to submit original certified payrolls as a condition for payment. The drawings specify materials and installation standards, including compliance with manufacturer specifications for all roofing materials, use of pressure-treated lumber in contact with masonry or exposed to weather, and installation of new fiberglass batt insulation to match existing adjacent materials. The contractor is responsible for verifying all dimensions in the field prior to construction commencement, obtaining all required permits and approvals, protecting or disconnecting existing electrical wiring and piping during construction, and documenting any existing damage prior to work initiation. No business enterprises have been awarded an identical or substantially similar procurement contract within the past five years. The project documentation indicates that a Roof Diagnostic Survey prepared by Tremco, Inc., dated June 14, 2022, identifying specific roof system deficiencies, is included as part of the bid document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 155 West Street Roof - Bid - Full Specs 2026.06.22.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NY ENGINEERING FIRM CERTIFICATE #0021419
26 IBM Road Poughkeepsie, NY 12601
CPL | Architecture Engineering Planning
CPLteam.com
FOR REVIEW ONLY
NOT FOR PERMIT OR
CONSTRUCTION
IT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW AND THE COMMISSIONER'S
REGULATIONS FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
ARCHITECT, ENGINEER OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ARCHITECT, ENGINEER OR SURVEYOR IS ALTERED, THE ALTERING
PARTY SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
NEW YORK STATE EDUCATION STATEMENT
Drawing Title
Drawn By
SHEET INFORMATION
Checked By
Drawing Number
Issued Scale
Project Status
PROFESSIONAL STAMPS
Client Name
Project Address
PROJECT INFORMATION
Project Name
Project Number
6/
/2
4:
:4
PM
CITY OF NEWBURGH
ROOF REPLACEMENT AT 155 WEST STREET
155 WEST STREET
NEWBURGH, NY 12550
PR
O
JE
C
T F
ILE
S O N
AC
C
ISSUED FOR BID
TITLE SHEET
TJG JD
06/22/2026
ISSUED FOR BID
G000
CITY OF NEWBURGH
155 WEST STREET
NEWBURGH, NY 12550
ROOF REPLACEMENT AT 155
WEST STREET
R22.15264.01
PROJECT ISSUE & REVISION SCHEDULE
# Date Description
VICINITY MAP 1"= +/- 1,000 FEET LOCATION MAP 1"= +/- 20 MILES
MAYOR
TORRANCE HARVEY
CITY COUNCIL
GISELLE MARTINEZ; WARD 1
RAMONA MONTEVERDE; WARD 2
TAMIKA E. STEWART; WARD 3
RONALD ZORILLA; WARD 4
ROBERT McLYMORE, SR.; AT-LARGE
OMARI SHAKUR; AT LARGE
INTERIM CITY MANAGER
JASON MORRIS
CITY CLERK
KATRINA COTTEN
PUBLIC WORKS SUPERINTENDENT
CHAD WADE
DRAWING LIST
GENERAL
G000 TITLE SHEET
ARCHITECTURAL
A001 GENERAL NOTES
A100 ROOF - EXISTING CONDITIONS/ DEMOLITION PLAN
A101 ROOF - REPLACEMENT PLAN
A102 ROOF - REPLACEMENT DETAILS
RD-1 RD-2
RD-4RD-3
V V V V
V V
V V P P
V
V
P
P P
RTU-1
RTU-2
RTU-3
RTU-11
RTU-12
RTU-7 RTU-8 RTU-9 RTU-10
RTU-5 RTU-6
RTU-4
ROOF
HATCH
+/- 59'-1"
9'
-3
1'-0" / 1'-0" 1'-0" / 1'-0"
1'-0" / 1'-0" 1'-0" / 1'-0"
SHADED AREA INDICATES ROOF SYSTEM
DEFICIENCY IDENTIFIED AS '1-E/T-03' IN
ROOF DIAGNOSTIC SURVEY PREPARED
BY 'TREMCO, INC.' DATED 6/14/22
SHADED AREA INDICATES ROOF SYSTEM
DEFICIENCY IDENTIFIED AS '1-B/T-02' IN
ROOF DIAGNOSTIC SURVEY PREPARED
BY 'TREMCO, INC.' DATED 6/14/22
SHADED AREA INDICATES ROOF SYSTEM
DEFICIENCY IDENTIFIED AS '1-A/T-01' IN
ROOF DIAGNOSTIC SURVEY PREPARED
BY 'TREMCO, INC.' DATED 6/14/22
SHADED AREA INDICATES ROOF SYSTEM
DEFICIENCY IDENTIFIED AS '1-D/P-01' IN
ROOF DIAGNOSTIC SURVEY PREPARED
BY 'TREMCO, INC.' DATED 6/14/22
NOTES
1. ROOF DIAGNOSTIC SURVEY PREPARED BY 'TREMCO, INC.' DATED 6/14/22
INCLUDED AS PART OF THIS BID DOCUMENT (AT/AROUND PAGES 166-168)
2. INFORMATION HEREON IS PROVIDED FOR REFERENCE ONLY.
3. THIS PLAN IS NOT INTENDED TO ILLUSTRATE CURRENT CONDITIONS. SEE
SELECTIVE DEMOLITION PLAN, SHEET A100.
GENERAL CONDITIONS
1. ALL WORK AND MATERIALS SHALL COMPLY WITH THE NEWEST EDITIONS OF THE BUILDING CODE OF NEW
YORK STATE, LOCAL BUILDING CODES, ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK
STATE, THE NATIONAL ELECTRIC CODE, NATIONAL BOARD OF FIRE UNDERWRITERS CODE, AND TO THE
REQUIREMENTS OF THE COUNTY BOARD OF HEALTH.
2. ANYTHING NOT SPECIFICALLY SHOWN HEREON AND/OR IN THE SPECIFICATIONS, BUT IS REASONABLY IMPLIED, SHALL BE FURNISHED AS THOUGH SET FORTH IN THE PLANS AND/OR SPECIFICATIONS. ALL WRITTEN FIGURES, NOTES AND DIMENSIONS ON THE PLANS OR SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ANY
DRAWN FIGURE. DO NOT SCALE PRINTS. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR
TO THE START OF ANY CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER PRIOR TO
THE START OF CONSTRUCTION.
3. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THEY HAVE THE
LATEST EDITION OF THE DOCUMENTS REFERENCED ABOVE.
4. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL REQUIRED
PERMITS AND APPROVALS HAVE BEEN OBTAINED. ALL REQUIRED PERMITS SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
5. ALL WORK MUST BE PERFORMED IN ACCORDANCE WITH THESE PLANS, SPECIFICATIONS AND CONDITIONS OF
APPROVAL; AND ALL APPLICABLE REQUIREMENTS, RULES, REGULATIONS, STATUTORY REQUIREMENTS, CODES, LAWS AND STANDARDS OF ALL GOVERNMENTAL ENTITIES WITH JURISDICTION OVER THIS PROJECT.
6. ALL MATERIALS USED IN PROJECT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS AND/OR GUIDELINES.
7. ALL DIMENSIONS SHOWN ON THE PLANS MUST BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO THE START OF
CONSTRUCTION. CONTRACTOR MUST NOTIFY THE ENGINEER IN WRITING, IF ANY CONFLICTS, DISCREPANCIES, OR AMBIGUITIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION. NO EXTRA COMPENSATION WILL BE PAID
TO THE CONTRACTOR FOR WORK WHICH HAS TO BE REDONE OR REPAIRED DUE TO DIMENSIONS OR GRADES
SHOWN INCORRECTLY ON THESE PLANS PRIOR TO THE CONTRACTOR GIVING ENGINEER WRITTEN
NOTIFICATION OF SAME AND ENGINEER, THEREAFTER, PROVIDING CONTRACTOR WITH WRITTEN
AUTHORIZATION TO PROCEED WITH SUCH ADDITIONAL WORK.
8. CONTRACTOR MUST IMMEDIATELY NOTIFY OWNER, ARCHITECT AND SITE ENGINEER, IN WRITING, OF ANY
CONFLICTS, DISCREPANCIES OR AMBIGUITIES WHICH EXIST.
9. DEBRIS MUST NOT BE BURIED ON THE SUBJECT SITE AND ALL DEBRIS (SOLID WASTE) MUST BE DISPOSED OF IN
ACCORDANCE WITH THE REQUIREMENTS OF ANY AND ALL GOVERNMENTAL AUTHORITIES WHICH HAVE
JURISDICTION OVER THIS PROJECT OR OVER CONTRACTOR.
10. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE DONE TO ANY NEW OR EXISTING
CONSTRUCTION OR PROPERTY DURING THE COURSE OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO
DRAINAGE, UTILITIES, PAVEMENT, STRIPING, CURB, ETC. AND SHALL BEAR ALL COSTS ASSOCIATED WITH SAME
TO INCLUDE, BUT NOT LIMITED TO, REDESIGN, RE-SURVEY, RE-PERMITTING AND CONSTRUCTION. THE
CONTRACTOR IS RESPONSIBLE FOR AND MUST REPLACE ALL SIGNAL INTERCONNECTION CABLE, WIRING
CONDUITS, AND ANY UNDERGROUND ACCESSORY EQUIPMENT DAMAGED DURING CONSTRUCTION AND
MUST BEAR ALL COSTS ASSOCIATED WITH SAME. THE REPAIR OF ANY SUCH NEW OR EXISTING CONSTRUCTION
OR PROPERTY MUST RESTORE SUCH CONSTRUCTION OR PROPERTY TO A CONDITION EQUIVALENT TO OR
BETTER THAN THE CONDITIONS PRIOR TO COMMENCEMENT OF THE CONSTRUCTION, AND IN CONFORMANCE
WITH APPLICABLE CODES, LAWS, RULES, REGULATIONS, STATUTORY REQUIREMENTS AND STATUTES.
CONTRACTOR IS RESPONSIBLE TO DOCUMENT ALL EXISTING DAMAGE AND TO NOTIFY THE OWNER AND THE
CONSTRUCTION MANAGER PRIOR TO THE START OF CONSTRUCTION.
11. THE ENGINEER HAS NOT BEEN RETAINED BY THE OWNER TO PROVIDE PERIODIC JOB INSPECTIONS OR JOB
ADMINISTRATION AND SHALL NOT BE RESPONSIBLE FOR OMISSIONS OR CHANGES MADE IN THE FIELD WITHOUT
PRIOR WRITTEN AUTHORIZATION.
CONTRACTOR NOTES
1. THE CONTRACTOR IS HEREBY NOTIFIED THAT SECTION 00 52 16 "STANDARD FORM OF AGREEMENT BETWEEN OWNER AND
CONTRACTOR ON THE BASIS OF A STIPULATED PRICE" AND ALL RELATED DOCUMENTS SHALL APPLY TO ALL WORK PERFORMED
UNDER THIS CONTRACT AND THESE CONSTRUCTION DOCUMENTS.
2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL ASSUME FULL AND TOTAL RESPONSIBILITY FOR THE
ACCURACY OF THE SAME.
3. IT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW, ARTICLE 145, SECTION 7209 FOR ANY PERSON, UNLESS HE IS ACTING
UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER ANY ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ENGINEER OR LAND SURVEYOR IS ALTERED, THE ALTERING ENGINEER OR LAND SURVEYOR SHALL AFFIX HIS
SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC
DESCRIPTION OF THE ALTERATION.
4. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL BE FAMILIARIZED WITH THE PROPOSED WORK, HAVING EXAMINED THE SITE, LOCAL CONDITIONS EFFECTING THE COST OF THE WORK, THE CONTRACT DOCUMENTS, PLANS AND SPEC.'S. THE CONTRACTOR'S
PRICE SHALL INCLUDE ALL TOOLS, EQUIPMENT, LABOR, MATERIALS AND SUPERVISION NECESSARY TO PERFORM THE WORK TO THE
SATISFACTION OF THE OWNER.
LUMBER
1. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR #2 OR BETTER, WITH A MINIMUM BENDING STRESS OF 1,250 PSI
AND A MODULUS OF ELASTICITY OF 1,3000,000. NON-BEARING STUD FRAMING SHALL BE S.P.F. #2 OR BETTER.
ENGINEERED LUMBER SHALL BE GLUE-LAM LVL AS MANUFACTURED BY 'TRUS JOIST CORP.' OR EQUAL.
GLUE-LAM BEAMS SHALL HAVE A MINIMUM BENDING STRESS OF 2,950 PSI.
2. LUMBER IN CONTACT WITH MASONRY, CONCRETE OR EXPOSED TO WEATHER SHALL BE PRESSURED TREATED.
3. FRAMING SHALL BE ERECTED PLUMB, LEVEL, TRUE AND SECURELY FASTENED.
4. SHEATHING SHALL BE APA RATED, T&G CDX PLYWOOD.
5. EXTERIOR SHEATHING SHALL BE FASTENED TO FRAMING WITH MINIMUM 8d GALVANIZED COMMON NAILS @
4" O.C. ALONG ALL SHEATHING EDGES OR OPENINGS, AND 12" O.C. AT INTERMEDIATE FRAMING MEMBERS.
6. BRIDGING SHALL BE SOLID WOOD 2" THICK AND THE SAME DEPTH AS MEMBER BRIDGED. BRIDGING SHALL BE
PROVIDED AT MID-POINT OF SPANS OVER 8'-0" LONG.
7. CONCEALED SPACES WITHIN WALL, FLOOR, STAIRS, ATTIC OR CORNICE CONSTRUCTION AND AROUND
CHIMNEY, PIPE AND DUCT OPENINGS SHALL BE FIRESTOPPED TO PREVENT PASSAGE OF FLAMES, SMOKE, FUMES AND HOT GASES. FIRESTOP THE FULL DEPTH OF JOISTS AT ALL POINTS OF SUPPORT. FIRESTOPPING SHALL BE SOLID
WOOD BLOCKING OR NON-COMBUSTIBLE MATERIAL.
8. CONTRACTOR SHALL USE ALUMINUM OR GALVANIZED NAILS ON ALL EXTERIOR WORK.
THERMAL AND MOISTURE PROTECTION
1. ALL ROOFING AND SIDING MATERIALS SHALL BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS.
2. ALL EXTERIOR JOINTS BETWEEN WINDOWS, DOORS AND OTHER SURFACES SHALL BE CAULKED WITH A WATERPROOF CAULKING.
CODE COMPLIANCE SUMMARY
BUILDING CODE(S)
- EXISTING BUILDING CODE OF NEW YORK STATE - 2025 (EBCNYS)
- BUILDING CODE OF NEW YORK STATE - 2025 (BCNYS) AS REFERENCED BY ABOVE
- ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE-2025 (ECCCNYS)
CLASSIFICATION OF WORK (EBCNYS): ALTERATION - LEVEL 1
USE AND OCCUPANCY CLASSIFICATION (BCNYS): GROUP B (BUSINESS GROUP)
CONSTRUCTION TYPE (BCNYS): TYPE V (602.5)
DESIGN LOADS: ROOF LIVE LOAD (SNOW): N/A (EXIST.)
ROOF DEAD LOAD: N/A (EXIST.)
WIND LOAD: 115 MPH
[ASCE 7-16; 3 SECOND GUST;
RISK CATEGORY II]
FIRE PROTECTION (BCNYS): NOT APPLICABLE
MEANS OF EGRESS (BCNYS): NOT APPLICABLE
ACCESSIBILITY (BCNYS): NOT APPLICABLE
STRUCTURAL (BCNYS): EXISTING TO REMAIN
ELECTRICAL (BCNYS): EXISTING TO REMAIN
MECHANICAL (BCNYS): EXISTING TO REMAIN
PLUMBING (BCNYS): EXISTING TO REMAIN
LEGEND
SECTION (LETTER) OR
DETAIL (NUMERAL)
DESIGNATION
SHEET NUMBER WHERE
SECTION OR DETAIL
IS LOCATED
BOUNDARY AREA OF
KEYED SECTION OR
DETAIL
SECTION (LETTER) OR
DETAIL (NUMERAL) DESIGNATION
SHEET NUMBER WHERE
SECTION OR DETAIL IS LOCATED
'CUT' LINE OF
SECTION OR DETAIL
INDICATES PARTIAL SECTION
OR DETAIL WHEN PRESENT
DIRECTION OF VIEW
OBJECTS IN VIEW (IMMEDIATE)
OBJECTS IN VIEW (BEYOND)
OBJECTS (HIDDEN)
C
A100
C
A100
A
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AWP ACOUSTICAL WALL PANEL
ADJ ADJACENT
A/C AIR CONDITIONING
ALT ALTERNATE
ALUM ALUMINUM
AB ANCHOR BOLT
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
AD AREA DRAIN
AGL ART GLASS
ACM ASBESTOS CONTAINING MATERIAL
@ AT
AUTO AUTOMATIC
B
BP BEARING PLATE
BM BENCH MARK
BITUM BITUMINOUS
BLK BLOCK
BLKG BLOCKING
BD BOARD
BOT BOTTOM
BRK BRICK
BLDG BUILDING
BN BULLNOSE
C
CAB CABINET
CPT CARPET
CI CAST IRON
CB CATCH BASIN OR CHALK BOARD
CLG CEILING
CLG HT CEILING HEIGHT
CL CENTER LINE
CER CERAMIC
CHR CHAIR RAIL
CIRC CIRCUMFERENCE
CO CLEAN OUT
CLR CLEAR
COL COLUMN
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONST CONSTRUCTION
CJT CONSTRUCTION JOINT
CONT CONTINUOUS
CONTR CONTRACTOR
CJ CONTROL JOINT
CG CORNER GUARD
CR CRASH RAIL
D
DP DAMP PROOFING
DEMO DEMOLISH
DEPT DEPARTMENT
DET,DTL DETAIL
DIA DIAMETER
DG DIGITAL GRAPHIC
DWC DIGITIAL WALL COVERING
DWP DIGITIAL WALL PANEL
DIM DIMENSION
DISP DISPENSER
DSP DISPOSAL
DO DITTO, REPEAT, SAME
DS DIVIDER STRIP
DR DOOR
DBL DOUBLE
DN DOWN
DS DOWNSPOUT
DT DRAIN TILE
DWR DRAWER
DWG DRAWING
DF DRINKING FOUNTAIN
E
EA EACH
EF EACH FACE
EW EACH WAY
E EAST
ELEC ELECTRICAL
ELEV ELEVATION
EL ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENTR ENTRANCE
EPT EPOXY PAINT
ERF EPOXY RESIN FLOOR
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE(D)
EXHST EXHAUST
EXIST EXISTING
ETR EXISTING TO REMAIN
EXP EXPANSION
EJ EXPANSION JOINT
INSUL INSULATION
INT INTERIOR
INTERM INTERMEDIATE
INV INVERT
J
JAN JANITOR
JS JANITOR SINK
JT JOINT
K
KIT KITCHEN
L
LBL LABEL
LAB LABORATORY
LAM LAMINATE(D)
LAV LAVATORY
LYR LAYER
LDR LEADER
LH LEFT HAND
LIB LIBRARY
LT LIGHT
LW LIGHT WEIGHT
LVT LUXURY VINYL TILE
M
MACH MACHINE
MH MAN HOLE
MHC MAN HOLE COVER
MFR MANUFACTURE
MFRR MANUFACTURER
MAS MASONRY
MO MASONRY OPENING
MAT MATERIALS
MAX MAXIMUM
MECH MECHANICAL
MET METAL
MTL METAL
M METER
MEZZ MEZZANINE
MIN MINIMUM
MISC MISCELLANEOUS
MR MOISTURE RESISTANT
MTD MOUNTED
N
NAT NATURAL
NRC NOISE REDUCTION COEFFICIENT
NOM NOMINAL
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NY ENGINEERING FIRM CERTIFICATE #0021419
26 IBM Road
Poughkeepsie, NY 12601
CPL | Architecture Engineering Planning
CPLteam.com
FOR REVIEW ONLY
NOT FOR PERMIT O
R
CONSTRUCTIO
N
IT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW AND THE COMMISSIONER'S
REGULATIONS FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
ARCHITECT, ENGINEER OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ARCHITECT, ENGINEER OR SURVEYOR IS ALTERED, THE ALTERING
PARTY SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY
THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
NEW YORK STATE EDUCATION STATEMENT
Drawing Title
Drawn By
SHEET INFORMATION
Checked By
Drawing Number
Issued Scale
Project Status
PROFESSIONAL STAMPS
Client Name
Project Address
PROJECT INFORMATION
Project Name
Project Number
/2
/2
:0
:0
A M
As indicated
P R
O
JE
C T
FI
LE
S O
N A
C C
GENERAL NOTES
TJG JD
06/22/2026
ISSUED FOR BID
NWS
A001
CITY OF NEWBURGH
155 WEST STREET
NEWBURGH, NY 12550
ROOF REPLACEMENT AT 155
WEST STREET
R22.15264.01
PROJECT ISSUE & REVISION SCHEDULE
# Date Description
PROJECT
NORTH
TRUE
NORTH
1/8" = 1'-0"A001
1 REFERENCE PLAN - ROOF DIAGNOSTIC SURVEY
SAN SANITARY
SCHED SCHEDULE
SCON SEALED CONCRETE
SEC SECOND
SECT SECTION
SIM SIMILAR
SSM SOLID SURFACE MATERIAL
STC SOUND TRANSMISSION
COEFFICIENT
SC SPECIALTY CEILING
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
SN STAIR NOSE & RISER
STD STANDARD
STL STEEL
SV STONE VENEER
STOR STORAGE
SGFT STRUCTURAL GLAZED FACING TILE
ST STL STRUCTURAL STEEL
STRUCT STRUCTURE, STRUCTURAL
SUSP SUSPENDED
SAT SUSPENDED ACOUSTICAL TILE
T
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
THK THICKNESS
TB TILE BASE
TF TILE FLOOR
TPD TOILET PAPER DISPENSER
TOS TOP OF SLAB/STEEL
TOW TOP OF WALL
TR TRIM
TYP TYPICAL
U
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UPH UPHOLSTERY
U URINAL
V
VEN VENEER
VIF VERIFY IN FIELD
VEST VESTIBULE
VCT VINYL COMPOSITION TILE
VET VINYL ENHANCED TILE
VQT VINYL QUARTZ TILE
VOL VOLUME
W
WOM WALK OFF MATT
WG WALL GUARD
WLT WALL TILE
WC WATER CLOSET
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
W WEST
WIND WINDOW
W/ WITH
W/O WITHOUT
WD WOOD
WS WRITEABLE SURFACE
Y
YD YARD
NO, # NUMBER
O
OC ON CENTER
OPNG OPENING
OD OUTSIDE DIAMETER
OH OVERHEAD
P
PT PAINT(ED)
PR PAIR
PTR PAPER TOWEL RECEPTOR
PKG PARKING
PART BD PARTICLE BOARD
PART PARTITION
PTM PATCH TO MATCH
PVMT PAVEMENT
PL PLATE
PLBG PLUMBING
PLYWD PLYWOOD
PVC POLYVINYL CHLORIDE
PC CONC PRECAST CONCRETE
PRE FAB PREFABRICATED
PT PRESSURE TREATED
PL PROPERTY LINE
Q
QTY QUANTITY
QB QUARRY BASE
QT QUARRY TILE
QTZ QUARTZ
R
RAD RADIUS
RECP RECEPTACLE
RE: REFER TO
REF REFERENCE
REFR REFRIGERATOR
REINF REINFORCED(ING)
REQ'D REQUIRED
RB RESILIENT BASE
RS RESILIENT SHEET
RST RESILIENT STAIR TREAD
RT RESILIENT TILE
RP RESIN PANEL
REV REVISED
RH RIGHT HAND
R RISER
RD ROOF DRAIN
RM ROOM
RO ROUGH OPENING
S
F
FAB FABRICATE
FT FEET
FRP FIBER REINFORCED PANEL
FIG FIGURE
FIN FINISH
FF FINISH FLOOR
FEC FIRE EXTINGUISHER CABINET
FH FIRE HOSE
FL,FLR FLOOR
FD FLOOR DRAIN
FTG FOOTING
FND FOUNDATION
FS FULL SIZE
FUT FUTURE
G
GALV GALVANIZED
G GAS
GA GAUGE
GEN GENERAL
GC GENERAL CONTRACTOR
GL GLASS, GLAZING
GB GRAB BAR
GR GRADE, GRADING
GSF GROSS SQUARE FOOT
GRT GROUT
GYP GYPSUM
GYP BD GYPSUM BD
GWB GYPSUM WALL BOARD
H
HDWR HARDWARE
HDWD HARDWOOD
HVAC HEATING, VENTILATING & AIR
CONDITIONING
HT, HGT HEIGHT
HEX HEXAGONAL
HPL HIGH PRESSURE PLASTIC
LAMINATE
HWY HIGHWAY
HM HOLLOW METAL
HORZ HORIZONTAL
HB HOSE BIBB
HW HOT WATER
HR HOUR
I
IN INCH
INCL INCLUDING
ID INSIDE DIAMETER
RD-1 RD-2
RD-4RD-3
V V V V
V V
V V
V
V
RTU-1
RTU-2
RTU-3
RTU-11
RTU-12
RTU-7 RTU-8
RTU-9 RTU-10
RTU-5 RTU-6
RTU-4
ROOF
HATCH
1'-0" / 1'-0" 1'-0" / 1'-0" 1'-0" / 1'-0" 1'-0" / 1'-0"
HOLD
2'-0" 71'-9 5/8"
HOLD
2'-0"
H O
LD
2' -0
'-7
/8
H O
LD
2'
-0
H O
LD
2'
-0
'-3
/8
H O
LD
2' -0
HOLD
2'-0" 40'-10 3/8"
HOLD
2'-0"
HOLD
2'-0" 26'-11 1/4"
HOLD
2'-0"
H O
LD
2' -0
'-1
1/ 2"
H O
LD
2' -0
DASHED LINE INDICATES FACE
OF EXTERIOR WALL BELOW EXISTING STORM GUTTERS TO REMAIN
SAW-CUT RIDGE AND PROVIDE 1" OPENING FOR NEW RIDGE VENT
EXISTING ASPHALT
SHINGLES TO REMAIN (TYP.)
D A
SH
ED
L
IN
E
IN
D
IC
A
TE
S
FA
C E
O F
EX
TE
R
IO
R W
A
LL
B
EL
O W
SA
W
-C U
T R
ID
G
E A
N D
P R
O V
ID
E
1" O
P
EN
IN
G
F O
R N
EW
R
ID
G
E V
EN
T
EX
IS
TI
N
G A
SP
H
A
LT
SH
IN
G
LE
S
TO
R
EM
A
IN
TY
P
EX
IS
TI
N
G S
TO
R
M G
U
TT
ER
S
TO
R
EM
A
IN
DASHED LINE INDICATES FACE
OF EXTERIOR WALL BELOW
EXISTING STORM GUTTERS TO REMAIN
SAW-CUT RIDGE AND PROVIDE 1" OPENING FOR NEW RIDGE VENT
EXISTING ASPHALT
SHINGLES TO REMAIN (TYP.)
D A
SH
ED
L
IN
E
IN
D
IC
A
TE
S
FA
C E
O F
EX
TE
R
IO
R W
A
LL
B
EL
O W
SA
W
-C U
T R
ID
G
E A
N D
P R
O V
ID
E
1" O
P
EN
IN
G
F O
R N
EW
R
ID
G
E V
EN
T
EX
IS
TI
N
G A
SP
H
A
LT
SH
IN
G
LE
S
TO
R
EM
A
IN
TY
P
EX
IS
TI
N
G S
TO
R
M G
U
TT
ER
S
TO
R
EM
A
IN
D1
D1
D1
D1D1
D2
D3
D5
D5
D5
D6
D4
+/- 59'-1"
9'
-3
REMOVE EPDM MEMBRANE
AND RIGID INSULATION DOWN
TO PLYWOOD SUBSTRATE THIS
AREA (APPROX. 4,221 S.F.)
T1
T1
T1
T2
T2
P1
P1
P1
P P
P2
P2
P2
P
P
P
NOTES
1. ROOF DIAGNOSTIC SURVEY PREPARED BY 'TREMCO, INC.' DATED 6/14/22 INCLUDED AS PART OF THIS BID DOCUMENT (AT/AROUND PAGES 166-168). SEE ALSO SHEET A001.
2. REMOVE EXISTING EPDM ROOFING MEMBRANE IN ITS ENTIRETY. REMOVAL SHALL INCLUDE BUT MAY NOT BE LIMITED TO:
- REMOVAL OF EXISTING PAVERS SUPPORTING ROOF-TOP EQUIPMENT.
- REMOVAL OF EXISTING BOOT FLASHINGS AND PITCH POCKETS.
- REMOVAL OF EXISTING ROOF DRAIN STRAINERS AND MOUNTING FLANGES.
- REMOVAL OF BASE FLASHINGS AT INTERSECTION WITH SHINGLED MANSARD ROOF.
3. REMOVE EXISTING RIGID INSULATION UNDER FLAT ROOF IN ITS ENTIRETY.
4. EXISTING MEMBRANE INSTALLATION METHOD IS UNKNOWN.
5. ACQUISITION OF A REFRIGERANT RECOVERY TECHNICIAN IS REQUIRED TO COMPLETE WORK ON ROOF-TOP HVAC UNITS. SEE SPECIFICATION SECTION 024110 'SELECTIVE STRUCTURE
DEMOLITION'.
6. SELECTIVE DEMOLITION AND JOIST LOCATIONS OUTLINED ON THE PLAN ARE APPROXIMATE AND ARE TO BE CONFIRMED BY THE CONTRACTOR PRIOR TO THE START OF WORK.
7. ANY SHEATHING/ SUBSTRATE, JOISTS OR BATT INSULATION FOUND TO BE ROTTED OR DAMAGED SHALL BE REMOVED.
A100
A100
A100
A100
A100
P
P
DEMOLITION KEYED NOTES
D1 CUT AND REMOVE 4'x8' AREA; BATT INSULATION, SHEATHING AND SUBSTRATE
D2 CUT AND REMOVE 16'x16' AREA; BATT INSULATION, SHEATHING AND
SUBSTRATE
D3 CUT AND REMOVE DETERIORATED BATT INSULATION, SHEATHING AND
SUBSTRATE, THIS AREA
D4 CUT AND REMOVE BATT INSULATION, SHEATHING AND SUBSTRATE IN AREA OF
ROOF DRAIN
D6 REMOVE (4) DETERIORATED 16" AJS25 JOISTS (APPROX. 23' LENGTH) AND
MICROLLAM HEADER
D5 REMOVE DETERIORATED 16" AJS25 JOIST (APPROX. 23' LENGTH)
T1 EXISTING ROOF TOP UNITS TO BE RAISED TO PERMIT REMOVAL OF EXISTING
PAVER BASES. PAVER BASES TO BE DISCARDED. COORDINATE WORK WITH ALL
ASSOCIATED TRADES.
T2 EXISTING ROOF TOP UNITS TO BE CAREFULLY REMOVED, STORED AND
PREPARED FOR RE-INSTALLATION OVER NEW ROOF CURBS
P1 PREPARE ALL VENT PENETRATIONS FOR NEW BOOT FLASHINGS
P2 PREPARE ALL CABLE PENETRATIONS FOR NEW FLASHING SYSTEMS
RTU-1 RTU-11RTU-7 RTU-8 RTU-9 RTU-10
SAW-CUT AND PROVIDE 1"
OPENING FOR NEW
CONTINUOUS RIDGE VENT
PRESUMED RAFTER FRAMING
AT PERIMETER MANSARD ROOF
ASPHALT SHINGLES
TO REMAIN
EXISTING EPDM ROOF MEMBRANE
AND RIGID INSULATION TO BE
REMOVED IN THEIR ENTIRETY.
REMOVE SUBSTRATE WHERE NECESSARY
PRESUMED JOIST FRAMING AT FLAT ROOF AREA
EXISTING ROOF TOP UNITS TO BE CAREFULLY
REMOVED , STORED AND PREPARED FOR
RE-INSTALL OVER NEW ROOF CURBS
SAW-CUT AND PROVIDE 1"
OPENING FOR NEW
CONTINUOUS RIDGE VENT
ASPHALT SHINGLES
TO REMAIN
EXISTING ROOF DRAINS TO REMAIN
EXISTING ROOF TOP UNITS TO BE
REMOVED AND PREPARED FOR
RE-INSTALL OVER NEW ROOF CURBS
EXISTING EPDM ROOF MEMBRANE
AND RIGID INSULATION TO BE
REMOVED IN THEIR ENTIRETY.
REMOVE SUBSTRATE WHERE NECESSARY
ROOF TOP UNITS TO BE RAISED TO
PERMIT REMOVAL OF EXISTING
PAVER BASES. COORDINATE WORK
WITH ALL ASSOCIATED TRADES
A100
A100
A100
RTU-3 RTU-2 RTU-1
RD-3
SAW-CUT AND PROVIDE 1"
OPENING FOR NEW
CONTINUOUS RIDGE VENT
PRESUMED RAFTER FRAMING
AT PERIMETER MANSARD ROOF
ASPHALT SHINGLES
TO REMAIN
EXISTING ROOF DRAINS TO REMAIN
EXISTING ROOF TOP UNITS TO BE
REMOVED AND PREPARED FOR
RE-INSTALL OVER NEW ROOF CURBS
EXISTING EPDM ROOF MEMBRANE
TO BE REMOVED IN IT'S ENTIRETY
PRESUMED JOIST FRAMING AT FLAT ROOF AREA
A100
SAW-CUT AND PROVIDE 1"
OPENING FOR NEW
CONTINUOUS RIDGE VENT
SAW-CUT AND PROVIDE 1" OPENING
FOR NEW CONTINUOUS RIDGE VENT
PRESUMED RAFTER FRAMING
AT PERIMETER MANSARD ROOF
ASPHALT SHINGLES TO REMAIN
1"
2'-0"
PREPARE ALL PENETRATIONS
FOR NEW BOOT FLASHINGS
PRESUMED ROOF FRAMING
EXISTING ROOF TOP UNITS TO BE
CAREFULLY REMOVED, STORED
AND PREPARED FOR RE-INSTALL
OVER NEW ROOF CURBS
CUT AND REMOVE ROOF
MEMBRANE, RIGID INSULATION AND
SUBSTRATE WHERE NECESSARY
ASPHALT SHINGLES
TO REMAIN
PRESUMED
RAFTER FRAMING
AT PERIMETER
MANSARD ROOF
16"AJS25 JOIST
(2) 1.75"x16" MICROLAM
(2) 1.75"x16" MICROLAM
16"AJS25 JOIST
16"AJS25 JOIST
(2
1.
"x
M
IC
R
O
LA
M
SE
E
N O
TE
O
SB
R
IM
B O
A R
D
SE
E
N O
TE
16"AJS25 JOIST
16"AJS25 JOIST
TO BE REMOVED
16"AJS25 JOIST
STEEL BEAM BELOW
2x BEARING PLATE BELOW
EXISTING BILCO
TYPE 'E' ROOF HATCH
16"AJS25 JOIST
TO BE REMOVED
16"AJS25 JOIST
TO BE REMOVED
16"AJS25 JOIST
TO BE REMOVED
NOTES:
1) REMOVE EXISTING ROOFING, BATT
INSULATION AND SUBSTRATE PER
DEMOLITION PLAN.
2) REMOVE, RE-FURBISH AND STORE
EXISTING ROOF HATCH FOR RE-
INSTALLATION.
3) REMOVE EXISTING PLYWOOD
SHEATHING WHERE DAMAGED OR
DETERIORATED.
4) REMOVE DETERIORATED MicroLam
HEADER. PROVIDE TEMPORARY SUPPORT
FOR EXISTING ROOF JOIST.
5) REMOVE EXISTING OSB RIMBOARD AND
(4) 16" AJS25 JOISTS (APPROX. 23'
LENGTH)
6) REMOVE EXISTING BATT INSULATION
(WITHIN ROOF FRAMING CAVITY) ALL
AROUND ROOF HATCH TO FACILITATE
WORK.
N O
T E
A100
+/- 23'-0"
(2) 1.75"x16"
MICROLAM
BEYOND
(4) 16"AJS25
JOISTS
TO BE REMOVED
OSB RIMBOARD TO BE REMOVED
(2) 1.75"x16" MICROLAM
HEADER TO BE REMOVED
EXISTING 'BILCO' TYPE 'E' ROOF
HATCH TO BE REMOVED, RE-FURBISHED
AND STORED FOR RE-INSTALLATION
INTEGRITY OF EXISTING BEARING
PLATE TO BE EVALUATED BY
ARCHITECT ONCE EXPOSED TO VIEW
EXISTING STEEL BEAM
EXISTING EPDM ROOFING AND
RIGID INSULATION TO BE REMOVED
PER DEMOLITION PLAN.
EXISTING 3/4" T&G PLYWOOD
SHEATHING TO BE REMOVED
WHERE DAMAGED OR
DETERIORATED
REMOVE EXISTING BATT INSUL.
ALL AROUND ROOF HATCH TO
FACILITATE WORK
NY ENGINEERING FIRM CERTIFICATE #0021419
26 IBM Road
Poughkeepsie, NY 12601
CPL | Architecture Engineering Planning
CPLteam.com
FOR REVIEW ONLY
NOT FOR PERMIT O
R
CONSTRUCTIO
N
IT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW AND THE COMMISSIONER'S
REGULATIONS FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
ARCHITECT, ENGINEER OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ARCHITECT, ENGINEER OR SURVEYOR IS ALTERED, THE ALTERING
PARTY SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY
THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
NEW YORK STATE EDUCATION STATEMENT
Drawing Title
Drawn By
SHEET INFORMATION
Checked By
Drawing Number
Issued Scale
Project Status
PROFESSIONAL STAMPS
Client Name
Project Address
PROJECT INFORMATION
Project Name
Project Number
/2
/2
:0
:0
A M
As indicated
P R
O
JE
C T
FI
LE
S O
N A
C C
ROOF -
EXISTING CONDITIONS/
DEMOLITION PLAN
TJG JD
06/22/2026
ISSUED FOR BID
NWS
A100
CITY OF NEWBURGH
155 WEST STREET
NEWBURGH, NY 12550
ROOF REPLACEMENT AT 155
WEST STREET
R22.15264.01
PROJECT
NORTH
TRUE
NORTH
1/8" = 1'-0"A100
1 ROOF PLAN - EXISTING/ SELECTIVE DEMOLITION
PROJECT ISSUE & REVISION SCHEDULE
# Date Description
1/4" = 1'-0"A100
2 SECTION - EXISTING/ SELECTIVE DEMOLITION
1/4" = 1'-0"A100
3 PARTIAL SECTION - EXISTING/ SELECTIVE DEMOLITION
1" = 1'-0"A100
4 RIDGE DETAIL - EXISTING/ SELECTIVE DEMOLITION
1" = 1'-0"A100
5 DETAIL - EXISTING/ SELECTIVE DEMOLITION
3/4" = 1'-0"A100
6 FRAMING DETAIL - EXISTING/ SELECTIVE DEMOLITION
3/4" = 1'-0"A100
7 HATCH DETAIL - EXISTING/ SELECTIVE DEMOLITION
CONTINUOUS RIDGE VENT
INSTALL PER MANUFACTURER'S
PUBLISHED INSTALLATION INSTRUCTIONS
EXISTING ASPHALT SHINGLES
NEW CRICKET. SEE PLAN
PRESUMED EXISTING
MANSARD ROOF FRAMING
RTU-1 RTU-11
RTU-7
A102
F1 F1
N1
N1
A101
N1
F1
A102
A101
RTU-8 RTU-9 RTU-10
CONTINUOUS RIDGE VENT
INSTALL PER MANUFACTURER'S
PUBLISHED INSTALLATION INSTRUCTIONS
EXISTING ASPHALT SHINGLES
RTU-3 RTU-2 RTU-1
RD-3
A101
A102
A102
N1 N1 N1
F1 F1
A101
CONTINUOUS RIDGE VENT
INSTALL PER MANUFACTURER'S
PUBLISHED INSTALLATION INSTRUCTIONS
BASIS OF DESIGN
CONTINUOUS RIDGE VENT
'ShingleVent II ' AS MANUFACTURED
BY AIR VENT, INC. OR EQUAL
EXISTING FRAMING AT
PERIMETER
MANSARD ROOF TO REMAIN
PROVIDE 1" (MINIMUM) UNOBSTRUCTED
OPENING BETWEEN RAFTERS AT
UNDERSIDE OF SHEATHING FOR AIR FLOW
EXISTING ASPHALT SHINGLES
EXISTING 2x WOOD RIDGE
16"AJS25 JOIST
(2) 1.75"x16" MICROLAM
(2) 1.75"x16" MICROLAM
16"AJS25 JOIST
16"AJS25 JOIST
16"AJS25 JOIST
16"AJS25 JOIST
N O
T E
NEW (2) 1.75"x16"
MICROLAM HEADER
NEW 3/8" OSB RIMBOARD
NEW
16"AJS25 JOIST
NEW
16"AJS25 JOIST
NEW
16"AJS25 JOIST
NEW
16"AJS25 JOIST
EXISTING STEEL BEAM BELOW
2x EXISTING BEARING PLATE BELOW
EXISTING BILCO
TYPE 'E' ROOF HATCH
NOTES:
1) PROVIDE NEW 3/8" OSB RIMBOARD
FASTENED TO AJS ROOF JOISTS.
2) PROVIDE NEW (2) 1.75"x16"
MicroLam HEADER FASTENED TO
EXISTING MicroLam's WITH JOIST
HANGER.
3) PROVIDE NEW FIBERGLASS BATT
INSULATION WHERE PREVIOUSLY
REMOVED.
4) PROVIDE NEW 3/4" T&G CDX
PLYWOOD SHEATHING WHERE
PREVIOUSLY REMOVED.
5) PROVIDE NEW RIGID, TAPERED
INSULATION. SLOPE SURFACES TO
EXISTING ROOF DRAINS. PROVIDE
CRICKETS FOR POSITIVE FLOW
AROUND ALL ROOFTOP EQUIPMENT
AND/ OR CURBS.
6) PROVIDE (4) NEW 16" AJS25 JOISTS
(23' LENGTH)
A101
+/- 23'-0"
(2) 1.75"x16"
MICROLAM
BEYOND
(4) NEW
16" AJS25 JOISTS
SEE ROOF PLAN
NEW 3/8" OSB RIMBOARD
FASTENED TO EXISTING
ASJ ROOF JOISTS
NEW (2) 1.75"x16"
MICROLAM HEADER
RE-INSTALL EXISTING, RE-FURBISHED
'BILCO' TYPE 'E' ROOF HATCH
EXISTING BEARING PLATE
EXISTING STEEL BEAM
NEW ROOFING AND RIGID
INSULATION PER ROOF PLAN
NEW 3/4" T&G CDX PLYWOOD
SHEATHING WHERE REMOVED
NOTE:
PROVIDE CRICKETS FOR POSITIVE
DRAINAGE AROUND ALL ROOFTOP
EQUIPMENT AND CURBS
NEW FIBERGLASS BATT INSUL.
ALL AROUND ROOF HATCH
RD-1 RD-2
RD-4RD-3
V V V V
V V
V V
V
V
RTU-1
RTU-2
RTU-3
RTU-11
RTU-12
RTU-7 RTU-8
RTU-9 RTU-10
RTU-5 RTU-6
RTU-4
ROOF
HATCH
1'-0" / 1'-0" 1'-0" / 1'-0"
1'-0" / 1'-0" 1'-0" / 1'-0"
HOLD
2'-0" 71'-9 5/8"
HOLD
2'-0"
H O
LD
2' -0
'-7
/8
H O
LD
2'
-0
H O
LD
2'
-0
'-3
/8
H O
LD
2' -0
HOLD
2'-0" 40'-10 3/8"
HOLD
2'-0"
HOLD
2'-0" 26'-11 1/4"
HOLD
2'-0"
H O
LD
2' -0
'-1
1/ 2"
H O
LD
2' -0
CONTINUOUS RIDGE VENT
C O
N
TI
N U
O U
S R
ID
G
E V
EN
T
CONTINUOUS RIDGE VENT
C O
N
TI
N U
O U
S R
ID
G
E V
EN
T
R1
R1
R1
R1R1
R2
R3
R5
R5
R5
R6
R4
+/- 59'-1"
9'
-3
INSTALL NEW 2-PLY SBS-
MODIFIED ROOFING SYSTEM
THIS AREA (APPROX. 4,221 S.F.)
SEE DETAIL 23/A102
N1
N1
N1
F1
F1
F2
F2
F2
NOTES
GENERAL:
1. EXISTING ELECTRICAL WIRING, CABLES AND/OR PIPING REQUIRED TO BE DISTURBED THROUGHOUT THE WORK AREA SHALL BE PROTECTED OR DISCONNECTED DURING
CONSTRUCTION AND RE-CONNECTED AFTER WORK IN AREA IS COMPLETED.
2. CONTRACTOR SHALL REPLACE ANY INTERIOR CEILING TILES REMOVED DURING CONSTRUCTION WITH NEW CEILING TILES.
RIDGE VENT:
3. INSTALL NEW CONTINUOUS RIDGE VENT ALONG MANSARD ROOF SECTIONS AS INDICATED ABOVE.
4. RIDGE VENTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS AND DETAIL #12, SHEET A101.
MEMBRANE ROOF REPLACEMENT:
5. INSTALL NEW SUBSTRATE MATERIALS WHERE REMOVED. THICKNESS OF NEW MATERIALS SHALL MATCH EXISTING ADJACENT MATERIALS.
6. CONSTRUCT NEW EQUIPMENT CURBS AS INDICATED ON PLAN AND DETAIL #13, SHEET A101.
7. PREPARE ALL ROOF PENETRATIONS FOR APPLICATION OF BOOTS, FLASHINGS, ETC. AS APPLICABLE.
8. INSTALL NEW RIGID INSULATION AS INDICATED ON PLAN.
9. CONSTRUCT NEW TAPERED INSULATION CRICKETS AS INDICATED ON PLAN.
10. INSTALL NEW ROOFING SYSTEM IN STRICT ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
11. INSTALL PROTECTION MATS/ WALKWAY PADS AS INDICATED ON PLAN. SEE DETAIL #22, SHEET A102.
N2
N3
F1
CONTINUOUS RIDGE VENT
C O
N
TI
N U
O U
S R
ID
G
E V
EN
T
A101
A101
A101
A101
A102
A102
A102
A102
NOTE
-TAPER RIGID INSULATION TO PROVIDE POSITIVE DRAINAGE
AROUND ROOF-TOP EQUIPMENT AND TO ROOF DRAIN
LOCATIONS.
-CONTRACTOR SHALL PROVIDE SHOP DRAWING PER
SPECIFICATION 075216.13 [1.04 (B)(2)]
-REFERENCE PLAN, SHEET A102 PROVIDED TO ILLUSTRATE DESIGN
INTENT ONLY
R7
R7
R7
R7
R8 R8
A101
A101
N1
N1
F2
ROOF PLAN KEYED NOTES
R1 INSTALL NEW SHEATHING/ SUBSTRATE AND BATT INSULATION (4'x8' AREA;
MATCH EXISTING ADJACENT)
R2 INSTALL NEW SHEATHING/ SUBSTRATE AND BATT INSULATION (16'x16' AREA;
MATCH EXISTING ADJACENT)
R3 INSTALL NEW SHEATHING/ SUBSTRATE AND BATT INSULATION THIS AREA
(MATCH EXISTING ADJACENT)
R4 INSTALL NEW SHEATHING/ SUBSTRATE AND BATT INSULATION IN AREA OF
ROOF DRAIN
R5 INSTALL NEW 16" AJS25 JOIST (APPROX. 23' LENGTH)
R6 INSTALL (4) NEW 16" AJS25 JOIST (APPROX. 23' LENGTH)
N1 INSTALL NEW STAND-OFF WALL FOR ROOF TOP UNITS. SEE DETAILS 13/A101
AND 24/A102
N2 INSTALL NEW STRUCTURAL FRAMING AT ROOF HATCH LOCATION. SEE DETAILS
14/A101 AND 15/A101
N3 INSTALL RE-FURBISHED ROOF HATCH ASSEMBLY OVER NEW FRAMING.
F1 VENT. SEE DETAIL 18/A102.
F2 CABLE PENETRATION FLASHING TYPICAL AS INDICATED . SEE DETAIL
19/A102.
R7 REPLACE MISSING SHINGLES THROUGHOUT THE ENTIRETY OF THE SLOPED
ROOF
R8 WALKWAY PADS (24"W) AS INDICATED
NY ENGINEERING FIRM CERTIFICATE #0021419
26 IBM Road
Poughkeepsie, NY 12601
CPL | Architecture Engineering Planning
CPLteam.com
FOR REVIEW ONLY
NOT FOR PERMIT O
R
CONSTRUCTIO
N
IT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW AND THE COMMISSIONER'S
REGULATIONS FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
ARCHITECT, ENGINEER OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ARCHITECT, ENGINEER OR SURVEYOR IS ALTERED, THE ALTERING
PARTY SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY
THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
NEW YORK STATE EDUCATION STATEMENT
Drawing Title
Drawn By
SHEET INFORMATION
Checked By
Drawing Number
Issued Scale
Project Status
PROFESSIONAL STAMPS
Client Name
Project Address
PROJECT INFORMATION
Project Name
Project Number
/2
/2
:0
:0
A M
As indicated
P R
O
JE
C T
FI
LE
S O
N A
C C
ROOF - REPLACEMENT PLAN
TJG JD
06/22/2026
ISSUED FOR BID
NWS
A101
CITY OF NEWBURGH
155 WEST STREET
NEWBURGH, NY 12550
ROOF REPLACEMENT AT 155
WEST STREET
R22.15264.01
PROJECT ISSUE & REVISION SCHEDULE
# Date Description
1/4" = 1'-0"A101
10 SECTION - REPAIRS
1/4" = 1'-0"A101
11 PARTIAL SECTION - REPAIRS
1" = 1'-0"A101
12 RIDGE VENT DETAIL
NTSA101
REPAIR DETAIL @ ROOF HATCH14
NTSA101
DETAIL @ ROOF HATCH15
1/8" = 1'-0"A101
1 ROOF PLAN - REPLACEMENT
NTSA101
STAND-OFF DETAIL13
PLUMBING VENT STACK
FLUID-APPLIED SYSTEM AS
RECOMMENDED BY ROOF
SYSTEM MANUFACTURER
SEAL AROUND PLUMBING
VENT WITH COMPATIBLE
SEALANT AS RECOMMENDED BY
ROOF SYSTEM MANUFACTURER.
MULTI-PLY MODIFIED BITUMEN
ROOFING
NOTES
2. MINIMUM RECOMMENDED FLASHING HEIGHT IS 8".
+/- 6"
1. VENT STACKS AND OTHER PIPES SHOULD HAVE A MINIMUM OF 12 INCHES OF CLEARANCE ON ALL
SIDES FROM WALLS, CURBS AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING.
MULTI-PLY MODIFIED
BITUMEN ROOFING
MEMBRANE PLIES, METAL FLASHING AND
STRIPPING SHEET EXTEND UNDER CLAMPING RING
EXISTING CAST-IRON DRAIN BOWL
EXISTING DECK CLAMP
EXISTING CLAMPING RING
TAPERED INSULATION SUMP
ROOF DECK PROPERLY
SUPPORTED AT DRAINS.
ROOF DRAIN HEIGHT FROM
DECK MAY VARY.
30'' SQUARE MINIMUM, 2 1/2 LB. LEAD OR 16 OZ. SOFT
COPPER FLASHING SET IN COMPATIBLE MASTIC AND
FOLDED INTO DRAIN; STRIP-IN WITH STRIPPING PLY
APPROX. 4"
FLUID-APPLIED SYSTEM AS
RECOMMENDED BY ROOF
SYSTEM MANUFACTURER;
APPLIED TO THE DRAIN SUMP
NOTES
1. PRIME ALL METAL SURFACES WITH APPROVED PRIMER.
2. INSTALL FLASHING SHEET IN APPROVED MASTIC AND STRIP-IN WITH APPROVED ADHESIVE.
3. PRIMING OF THE SUBSTRATE MAY BE REQUIRED, FOLLOW SPECIFICATIONS AND
MANUFACTURER RECOMMENDATIONS.
4. REMOVE EXISTING FLASHINGS PRIOR TO INSTALLATION OF NEW FLUID-APPLIED SYSTEMS.
5. REPLACE 'IN KIND' ANY ROOF DRAIN COMPONENTS FOUND TO BE DETERIORATED OR
DEFICIENT.
RD-1 RD-2
RD-4RD-3
V V V V
V V
V V
V
V
RTU-1
RTU-2
RTU-3
RTU-11
RTU-12
RTU-7 RTU-8
RTU-9 RTU-10
RTU-5 RTU-6
RTU-4
ROOF
HATCH
CONTINUOUS RIDGE VENT
C O
N
TI
N U
O U
S R
ID
G
E V
EN
T
ARROWS INDICATE DOWNWARD
SLOPES OF TAPERED ROOF PLANE
(TYPICAL)
P P
P
P
P
NOTES
1. THE PLAN ABOVE IS PROVIDED FOR REFERENCE ONLY AND IS INTENDED TO ILLUSTRATE DESIGN INTENT.
2. CONTRACTOR SHALL PROVIDE SHOP DRAWING(S) ILLUSTRATING SLOPES OF TAPERED INSULATION. SHOP
DRAWING(S) SHALL BE SUBJECT TO APPROVAL BY THE PROJECT ARCHITECT. SEE PROJECT SPECIFICATIONS.
C O
N
TI
N U
O U
S R
ID
G
E V
EN
T
C O
N
TI
N U
O U
S R
ID
G
E V
EN
T
CONTINUOUS RIDGE VENT CONTINUOUS RIDGE VENT
3" CANT STRIP
ALL AROUND
" M
IN
BY RTU DIMENSION
VARIES
BY RTU DIMENSION
VARIES
CAP/ FLASHINGS PER
ROOFING MANUFACTURER'S
INSTALLATION DETAILS
1/2" 'DENSDECK'
SHEATHING EACH SIDE
P.T. (2) 2X6 TOP PLATE
ROOFING SYSTEM
AS SPECIFIED
EXISTING ROOF
SHEATHING
EXISTING ROOF
JOIST
P.T. 2x6 STUDS
@ 16"O.C.
P.T. 2x6 PLATE FASTENED THROUGH
TO EXISTING JOIST w/ 3" (#12; 8TPI
MAX.) WOOD SCREWS @ 16"O.C.
NOTE
DETAIL PROVIDED TO ILLUSTRATE DESIGN INTENT.
SEE DETAIL, SHEET A101 FOR INFORMATION NOT PROVIDED HEREON.
1/2-INCH DENS DECK PRIME COVER BOARD
ADHERED IN LOW RISE FOAM INSULATION
ADHESIVE BEADS 12" O.C.
1/8-INCH SLOPE TAPERED POLYISOCYANURATE
INSULATION. MINIMUM 2" BASE LAYER. EACH
LAYER ADHERED IN LOW RISE FOAM
INSULATION ADHESIVE BEADS 12" O.C.
120-MIL SBS-MODIFIED BITUMEN
BASE PLY ADHERED IN COLD
ADHESIVE
EXISTING WOOD DECK
145-MIL GRANULE-SURFACED
SBS-MODIFIED BITUMEN CAP PLY
ADHERED IN COLD ADHESIVE
NEW TAPERED
INSULATION &
COVER BOARD
EXISTING EPDM MEMBRANE TO REMAIN ON
SLOPE. FASTEN AT BASE OF SLOPE 12"O.C.
REINFORCED FLUID-APPLIED FLASHINGS OVER CLEANED
& PRIMED EXISTING EPDM MEMBRANE TO SHINGLES.
EXTEND REINFORCED FLUID-APPLIED FLASHINGS SIX
INCHES ONTO FIELD OF SBS-MODIFIED ROOF
SHINGLES TO REMAIN
THREE-COURSE OF
POLYURETHANE SEAM SEALER &
FABRIC EXTEND 3" ONTO SBS
ROOF AND 3" UP SLOPE OVER
PRIMED EPDM
NEW 2-PLY SBS-
MODIFIED
BITUMEN ROOFING
6"
3" 3"
NY ENGINEERING FIRM CERTIFICATE #0021419
26 IBM Road
Poughkeepsie, NY 12601
CPL | Architecture Engineering Planning
CPLteam.com
FOR REVIEW ONLY
NOT FOR PERMIT O
R
CONSTRUCTIO
N
IT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW AND THE COMMISSIONER'S
REGULATIONS FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
ARCHITECT, ENGINEER OR LAND SURVEYOR, TO ALTER AN ITEM IN ANY WAY. IF AN ITEM
BEARING THE SEAL OF AN ARCHITECT, ENGINEER OR SURVEYOR IS ALTERED, THE ALTERING
PARTY SHALL AFFIX TO THE ITEM THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY
THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
NEW YORK STATE EDUCATION STATEMENT
Drawing Title
Drawn By
SHEET INFORMATION
Checked By
Drawing Number
Issued Scale
Project Status
PROFESSIONAL STAMPS
Client Name
Project Address
PROJECT INFORMATION
Project Name
Project Number
/2
/2
:0
:1
A M
As indicated
P R
O
JE
C T
FI
LE
S O
N A
C C
ROOF - REPLACEMENT DETAILS
TJG JD
06/22/2026
ISSUED FOR BID
NWS
A102
CITY OF NEWBURGH
155 WEST STREET
NEWBURGH, NY 12550
ROOF REPLACEMENT AT 155
WEST STREET
R22.15264.01
PROJECT ISSUE & REVISION SCHEDULE
# Date Description
NTSA102
PLUMBING VENT FLASHING
LIQUID-APPLIED FLASHING SYSTEMS18
NTSA102
ROOF DRAIN LIQUID-APPLIED
FLASHING SYSTEM26
3/32" = 1'-0"A102
1 REFERENCE PLAN - ROOF SLOPE LAYOUT
NTSA102
24 RTU EQUIPMENT STAND-OFF - PERSPECTIVE
12" = 1'-0"A102
22 2-PLY SBS-MODIFIED ROOF ASSEMBLY DETAIL
NTSA102
BASE FLASHING AT SHINGLES25
NTSA102
19 CABLE/ CONDUIT/ WIRE PENETRATION FLASHING DETAIL
| Sheets |
| A001 - GENERAL NOTES |
| A100 - ROOF - EXISTING CONDITIONS/ DEMOLITION PLAN |
| A101 - ROOF - REPLACEMENT PLAN |
| A102 - ROOF - REPLACEMENT DETAILS |
| G000 - TITLE SHEET |
File details come from the government source that posted it. Updated .